IP fast-switching error messages
Explanation A programming error occurred.
Recommended Action Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation A programming error occurred.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, and report it to your Cisco technical support representative.
Explanation The system attempted to add a cache entry for an invalid address.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, and report it to your Cisco technical support representative.
Explanation The system is invalidating all cache entries for a given interface.
Recommended Action No action is required.
Explanation The system is invalidating all cache requests for a given interface.
Recommended Action No action is required.
Explanation Problems related to the IP route cache triggered this debugging message.
Recommended Action The router should correct for this error. If the router cannot forward packets properly or is experiencing other problems, copy the error message exactly as it appears and report it to your Cisco technical support representative.
Explanation A programming error occurred.
Recommended Action Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Problems related to the IP route cache triggered this debugging message.
Recommended Action The router should correct for this error. If the router cannot forward packets properly or is experiencing other problems, copy the error message exactly as it appears and report it to your Cisco technical support representative.
IP flow error messages
Explanation Activation of a flow accelerated feature failed because of a sanity check.
Recommended Action Copy the message exactly as it appears and report it to your technical support representative.
Explanation Activation of a flow accelerated feature failed because of low memory.
Recommended Action Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.
Explanation Initialization of the Flow cache could not be accomplished because of a low memory condition.
Recommended Action Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Deactivation of a flow accelerated feature failed because of a sanity check.
Recommended Action Copy the message exactly as it appears and report it to your technical support representative.
Explanation Deactivation of a flow accelerated feature failed because of low memory.
Recommended Action Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.
Explanation Initialization of the Flow export queue could not be accomplished because of a low memory condition.
Recommended Action Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.
Explanation Initialization of the Flow background process could not be accomplished because of a low memory condition.
Recommended Action Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.
Explanation Initialization of the Flow feature queue could not be accomplished because of a low memory condition.
Recommended Action Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.
Gigabit Switch Router line card IP multicast error message
Explanation Errors occurred while processing an IP multicast packet.
Recommended Action Copy the error message exactly as it appears on the console, and report it to your technical support representative.
Internet Protocol routing error messages
Explanation A user specified an invalid BGP community list number.
Recommended Action Check the system configuration to ensure that the specified community list falls within the valid range.
Explanation An internal software error occurred.
Recommended Action If the message recurs, copy the error message exactly as it appears on the console or in the system log, and report it to your Cisco technical support representative.
Explanation The requested operation failed because of a low-memory condition.
Recommended Action Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.
Explanation A software error occurred.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, and report it to your Cisco technical support representative.
Simple Network Management Protocol specific to IP error messages
Explanation The user entered an snmp-server trap-source command. The interface requested for use as the source address has no address associated with it. The SNMP trap is being sent anyway, but without the source address that the user intended.
Recommended Action There are two possible solutions. Either enter a no snmp-server trap-source command to disable the request for a specific source IP address, or add an IP address to the interface referenced in the snmp-server trap-source configuration command.
Explanation The SNMP server was unable to open a port for receiving or transmitting SNMP requests. This usually happens when the SNMP server is started using the snmp-server community configuration command on a router or communication server with an interface that has no IP address configured. Another possible cause is low memory.
Recommended Action Configure at least one interface with an IP address or specify the no snmp-server command to remove the SNMP server process. Call your technical support representative if the problems persist or if it becomes necessary to add memory.
Explanation An incoming SNMP packet had a length field so large that the system had to assume it was in error. This system made a correct reaction to bad external data. Since SNMP packets should originate from systems under the same administration, this may indicate that the network host used to originate the SNMP request had a problem in its networking layer. Alternatively, if the SNMP packet originated from outside the local administrative domain, it could indicate a failed attempt at security penetration and that site should be watched more closely.
Recommended Action If the origin is local, no action is required. If the origin is determined to be malicious, either contact the administrator of the originating site or install filters to prevent access by that site, as circumstances warrant.
Internetwork Packet Exchange error messages
Explanation The internal SAP service count does not match the number of services currently present and displayed by the show ipx servers command.
Recommended Action If this message recurs, report the problem to your technical support representative, along with the output of the show px servers command taken before the message appeared and again after the message appeared.
Explanation An incremental SAP update could not be sent, because this might cause the SAP tables between peers to become out of synch.
Recommended Action Increase the output SAP delay on the listed interface to reduce buffer usage. If, after changing the delay, the message remains, copy the error message exactly as it appears and report it to your technical support representative.
Explanation There are two types of service access points (SAPs)---general queries and general responses. This message is sent when you receive or attempt to send a SAP with a type code that is not a general query or a general response. It is also sent when you receive a general query not addressed to the broadcast address.
Recommended Action Copy the error message exactly as it appears, and report it to your technical support representative. If possible, also provide the output of the debug ipx sap activity and debug ipx sap event commands for the period during which this message appeared.
Explanation An internal inconsistency was detected in the IPX routing table structure.
Recommended Action Copy and save this message. If possible, clear the IPX routing table by issuing the clear ipx route command. (This will result in lost connectivity until the routing table is rebuilt.) If the message recurs, copy and save the message, along with the output from the show ipx route, and call your technical support representative for assistance.
Explanation If IPX access violation logging is enabled, these messages are displayed when an access list logging event has occurred.
Recommended Action Verify that the host system is permitted or denied, as defined in the access list.
Explanation The limit of connected IPX networks has been reached. Additional IPX interfaces cannot be configured.
Recommended Action Do not configure IPX on additional interfaces. Remove IPX configuration commands from inactive interfaces.
Integrated Services Digital Network (ISDN) error messages
Explanation The requested channel is not available.
Recommended Action This is an informational message only. No action is required.
Explanation This is an informational message sent when a call is connected. The message displays the remote name and number, which it receives from the Point-to-Point Protocol (PPP) authentication or from where the dialer placed the call.
Recommended Action No action is required.
Explanation This is an informational message sent when a call is disconnected. The message displays the remote name and number, which it receives from the Point-to-Point Protocol (PPP) authentication or from where the dialer placed the call. It also shows how long the call lasted.
Recommended Action No action is required.
Explanation The incoming ISDN call is ignored because the Called Party Number does not match the LDN numbers configured in the router.
Recommended Action Correct the LDN in the router to match the Called Party Number delivered in the incoming setup message.
Explanation The incoming ISDN call is ignored because the EID delivered in the incoming setup message cannot be matched.
Recommended Action If EID is delivered in the setup message, use the isdn debugs and show isdn status commands to determine the current EID values. You may need to contact the service provider.
Explanation The service profile identifier (SPID) configured in the router has been rejected by the switch.
Recommended Action Determine the correct SPID, reenter the SPID and clear the BRI interface.
Explanation This message could indicate low memory. It is sent when an invalid ISDN timer handle is passed on for timer operations.
Recommended Action Capture the show isdn memory and show isdn status output for possible debugging information. Reduce other system activity to ease the memory demands in the system.
Explanation This is an informational message. It is sent when an ISDN Layer 2 logical link is down. It also shows the terminal endpoint identifier (TEI) associated with this logical link.
Recommended Action No action is required.
Explanation This is an informational message. It is sent when an ISDN Layer 2 logical link is up. It also shows the terminal endpoint identifier (TEI) associated with this logical link.
Recommended Action No action is required.
Explanation The requested operation could not be accomplished because of a low-memory condition.
Recommended Action Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.
Explanation This message could indicate low memory. It is sent when the ISDN protocol cannot start new timers for its operation.
Recommended Action Capture the show isdn memory and show isdn status output for possible debugging information. Reduce other system activity to ease the memory demands in the system.
Explanation A SETUP was received on top of a pending SETUP.
Recommended Action This is an informational message only. No action is required.
Local area network controller Ethernet interface error messages
Explanation An Ethernet interface is malfunctioning.
Recommended Action Determine whether the malfunction stems from a software or hardware error by turning off all fast switching. Error messages showing that the packet is too large for the link indicate a software error at a high level. Copy the error message exactly as it appears, and report it to your technical support representative. Receiving no error messages indicates a hardware error. Repair or replace the controller.
Explanation Ethernet cable is not connected.
Recommended Action Check Ethernet cable connection.
Explanation An internal software error occurred.
Recommended Action If either message recurs, call your technical support representative for assistance.
Explanation An Ethernet cable is broken or unterminated, or the transceiver is unplugged. The time delay reflectometer (TDR) counter is an internal LANCE counter that counts the time (in ticks of 100 ns each) from the start of a transmission to the occurrence of a collision. Because a transmission travels about 35 feet per tick, this value is useful to determine the approximate distance to a cable fault.
Recommended Action If the transceiver appears to be properly terminated, repair or replace the Ethernet interface card.
Explanation The hardware failed to initialize correctly.
Recommended Action Repair or replace the controller.
Explanation An Ethernet transceiver is malfunctioning, the Ethernet is overloaded, or the Ethernet cable is too long.
Recommended Action Repair or replace the controller.
Explanation An Ethernet transceiver is unplugged or faulty.
Recommended Action Repair or replace the controller.
Explanation An Ethernet interface detected a hardware problem.
Recommended Action Repair or replace the controller.
Explanation An Ethernet interface is malfunctioning, or an internal software error occurred.
Recommended Action Repair or replace the controller.
Explanation An Ethernet interface generated a spurious Initialization Done interrupt.
Recommended Action Repair or replace the controller.
Explanation The Ethernet hardware is requesting data faster than the system can supply it. This condition might indicate that the system is at the limit of its performance.
Recommended Action A small number of underflows might not be a cause for concern. You can monitor underflows with the show interface command. Reducing the load on the router or installing a higher-performance router should alleviate this problem.
LAN emulation error messages
Explanation An internal error occurred.
Recommended Action This error should not occur. Download the system error log, then call your technical support representative and provide the log, the error message, and the router configuration.
Explanation A name identifying a LANE component has been entered by the user that is longer than 32 characters.
Recommended Action Re-enter a shorter name.
Explanation An unexpected LAN type has been specified for a LANE component. Only Ethernet and Token Ring ELANs are supported.
Recommended Action Specify a valid LAN type.
Explanation This is an informational message about the LANE subsystem.
Recommended Action No action is required.
Explanation An internal error occurred, which reflects an inconsistency in the system and needs attention.
Recommended Action Copy the error message exactly as it appears, and report it to your technical support representative.
Explanation An internal error occurred while system routines were handling ATM signaling messages for LANE.
Recommended Action Copy the error message exactly as it appears, and report it to your technical support representative.
Explanation The client cannot obtain an ATM address from the given configuration, or auto-assignment failed to get an ATM prefix from the switch.
Recommended Action If you expect the switch to assign the prefix to the router, check that the Interim Local Management Interface (ILMI) is functional and the switch has a prefix configured. Otherwise, confirm that the client has an address in the nonvolatile RAM (NVRAM) configuration.
Explanation An incorrect BLLI value was specified on the incoming circuit.
Recommended Action The originator of the circuit is not using the correct BLLI value for this type of circuit. The LANE standard defines these values, and the originator is violating the standard.
Explanation The master LECS refused the LEC's configuration request.
Recommended Action Check your LECS configurations.
Explanation The LANE client received an unexpected or inappropriate control message over one of its VCs.
Recommended Action Copy the error message exactly as it appears, and report it to your technical support representative.
Explanation A LANE client software or hardware error occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your technical support representative.
Explanation This is an informational LANE message.
Recommended Action No action is required.
Explanation A LANE client's request to join its ELAN was rejected.
Recommended Action This message is usually the result of user configuration errors (such as the LANE client attempted to join an incorrect ELAN or the ELAN was not configured in the LES) or there were validation failures with the LECS.
Explanation The LANE client could not register its address with ATM signalling to be able to accepts calls on that address.
Recommended Action Reconfigure the client ATM address. It may be conflicting with another component with the same ATM address.
Explanation An attempt to register a MAC-ATM address binding with LES failed.
Recommended Action The LES had already registered the requested MAC address - ATM address binding.
Explanation An internal consistency error occurred.
Recommended Action Copy the error message exactly as it appears, and report it to your technical support representative.
Explanation ATM signaling sent the LANE client an unexpected message type.
Recommended Action Copy the error message exactly as it appears, and report it to your technical support representative.
Explanation This is an informational LECS message.
Recommended Action No action is required.
Explanation The LANE Configuration Server address could not be registered with or de-registered from the switch, using Interim Local Management Interface (ILMI). The following are possible causes. The switch prefix is not available. The address is not acceptable to the switch (the prefix does not conform). The interface over which this operation should take place is down. The ILMI subsystem on the router is not completely initialized.
Recommended Action Copy the error message exactly as it appears, and report it to your technical support representative.
Explanation The ELAN-ID returned by LES does not match the value given by LECS or by the CLI.
Recommended Action Check the ELAN-ID configurations specified in the LECS database and the LES. The mismatch must be the result of misconfiguration.
Explanation A serious internal occurred with LES/BUS.
Recommended Action This error should not occur. Download the system error log, then call your technical support representative and provide the log, the error message, and the router configuration.
Explanation A LANE server or BUS could not register its address with ILMI.
Recommended Action Investigate why this error occurred. It may be because a user defined override address does not conform to the switch prefix, or that there is a problem with the ATM switch with whom the entity is registering.
Explanation Software was unable to compute an ATM address based on the ATM address template given. The characters in [chars] will be either BUS (broadcast-and-unknown), server, or config server in the actual error message.
Recommended Action Enter a correct ATM address template for the LANE component (BUS, server, or config server) named in the error message.
Explanation A very serious LES/BUS internal error occurred.
Recommended Action This error should not occur. Download the system error log, then call your technical support representative and provide the log, the error message, and the router configuration.
Explanation The LANE server specified has 65,279 clients. No more can be added.
Recommended Action Change the configurations to avoid trying to have more than 65,279 LANE clients on this server.
Explanation Both the LANE client and the LANE server/BUS may have an emulated LAN name specified in the configuration via the lane server-bus and lane client commands. If both specify the emulated LAN name, then the name cannot be changed by re-entering just one of the commands.
Recommended Action Use the no lane server-bus command to delete the server-bus or the no lane client command to delete the client. Then, the other of the two commands can be re-entered with another emulated LAN name. Finally, re-enter the deleted command with the new emulated LAN name.
Explanation The Interim Local Management Interface (ILMI) feature is either not included in the software image running on the router, or is having other problems.
Recommended Action This error should not occur. Download the system error log, then call your technical support representative and provide the log, the error message, and the router configuration.
Explanation An attempt was made to create a new subinterface while a previous version of the subinterface was still being destroyed.
Recommended Action Wait a minute and try again. If failure still occurs, try shutting down the main interface. Rebooting may be required to recover in extreme cases.
Explanation An attempt to register the given ATM address with the ATM switch failed. This failure can occur because the ATM switch is down or misconfigured. The registration will be retried.
Recommended Action If the situation persists after a number of attempts, and the switch is up, the configuration of the switch and router should be examined. A likely cause is that the ATM address being registered is not compatible with the parameters configured in the switch. Correct the configuration.
Explanation Both the LANE client and the LANE Server/BUS may have an ELAN type specified in the configuration via the lane server-bus and lane client commands as either Ethernet or Token Ring. If both are configured, specify the type; the type cannot be changed by re-entering just one of the commands.
Recommended Action Use the no lane server-bus command to delete the server-bus or the no lane client command to delete the client. Then, the other of the two commands can be re-entered with a new type. Finally, re-enter the deleted command with the new type.
Explanation A LANE component changed its state to up or down.
Recommended Action If this event is expected, then take no action. Otherwise, contact a technical support representative.
IBM LAN Network Manager error messages
Explanation The router detected a conflict in assigned ring numbers for the specified Token Ring. The Ring Parameter Server (RPS) function was shut down to prevent potentially incorrect information from being sourced onto the ring.
Recommended Action Check all bridges connected to this Token Ring and ensure that they are using the same assigned ring number.
Explanation An internal software error occurred.
Recommended Action If the message recurs, copy the error message exactly as it appears on the console or in the system log, and report it to your Cisco technical support representative.
Explanation The requested operation failed because of a low-memory condition.
Recommended Action Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.
Explanation An internal software error occurred.
Recommended Action If the message recurs, copy the error message exactly as it appears on the console or in the system log, and report it to your Cisco technical support representative.
Explanation The software on this interface cannot support the functions required for LAN Network Manager.
Recommended Action Call your Cisco technical support representative about a firmware upgrade for this interface card.
X.25 Link Access Procedure, Balanced error messages
Explanation A received Frame Reject (FRMR) reported a frame with an invalid control code.
Recommended Action Check the serial line and the devices attached to the line.
Explanation A Frame Reject (FRMR) frame was received, indicating that a protocol violation was detected. The Reason field will be interpreted by generating INFOBAD, CTRLBAD, N1TOOBIG, or INVNR messages immediately after this message; refer to the explanations for these messages for more information.
Recommended Action The protocol will recover by resetting the service. This will disrupt any network service on top of LAPB (for example, X.25 virtual circuits will be cleared). Follow the recommended action for any error message following the FRMR reports. If service becomes unacceptable, check the serial line and its attached devices.
Explanation A received Frame Reject (FRMR) frame reported that an information field was present in a frame where no information field is allowed.
Recommended Action Check the serial line and the device attached to the line.
Explanation A received Frame Reject (FRMR) reported a frame with an invalid N(R) value.
Recommended Action Verify that the equipment attached to the serial line is configured with the same K value (maximum number of outstanding I frames).
Explanation A received Frame Reject (FRMR) reported an information frame that was too long.
Recommended Action Verify that the equipment attached to the serial line is configured with the same N1 value. N1 is in bits and includes the entire frame plus 16 bits of CRC. However, some equipment may require configuration in octets, the omission of the two CRC octets, or the omission of the three octets of LAPB control information.
Explanation There was insufficient memory for the LAPB protocol engine to send a message.
Recommended Action This message is acceptable if it occurs infrequently, because the LAPB protocol is designed to handle loss of frames. Frequent occurrences can cause disruption of service. The system can be configured to ease memory demands or, if conditions warrant, the system can be upgraded to a larger memory configuration.
Explanation An internal software error occurred.
Recommended Action If either of these messages recur, call your technical support representative for assistance.
Explanation An internal software error occurred.
Recommended Action If either of these messages recur, call your technical support representative for assistance.
DEC Local Area Transport error messages
Explanation An internal software error occurred.
Recommended Action If this message recurs, contact your technical support representative.
Explanation An internal software error occurred.
Recommended Action If this message recurs, contact your technical support representative.
Explanation An internal software error occurred.
Recommended Action If this message recurs, contact your technical support representative.
Explanation An internal software error occurred.
Recommended Action If this message recurs, contact your technical support representative.
Explanation An internal software error occurred.
Recommended Action If this message recurs, contact your technical support representative.
Explanation An internal software error occurred.
Recommended Action If this message recurs, contact your technical support representative.
Line card error messages
Explanation The number of buffers in one of the BMA queues has overflowed.
Recommended Action Copy the error message exactly as it appears, and report it to your technical support representative
Explanation The BMA encountered problems while trying to fetch the given command. If the message appears more than once you may have a hardware problem. The GRP should recognize that communication has been lost with the line card and reload it.
Recommended Action Copy the error message exactly as it appears, and report it to your technical support representative.
Explanation The given BMA has lost a command. If the message appears more than once you may have a hardware problem. The GRP should recognize that communication has been lost with the line card and reload it.
Recommended Action Copy the error message exactly as it appears, and report it to your technical support representative.
Explanation There was a problem in the reply to the given BMA command. If the message appears more than once you may have a hardware problem. The GRP should recognize that communication has been lost with the line card and reload it.
Explanation Copy the error message exactly as it appears, and report it to your technical support representative
Explanation There is an error in the BMA (reg. information).
Recommended Action Copy the error message exactly as it appears, and report it to your technical support representative
Explanation There is an error in the BMA.
Recommended Action Copy the error message exactly as it appears, and report it to your technical support representative
Explanation There is an error in the BMA.
Recommended Action Copy the error message exactly as it appears, and report it to your technical support representative
Explanation When the BMA microcode download command was issued, the given BMA microcode bundled in the image was not retrieved.
Recommended Action Copy the error message exactly as it appears, and report it to your technical support representative
Explanation When the BMA microcode download command was issued, there was a mismatch between what was specified in the BMA microcode file and the current type of line card
Recommended Action Copy the error message exactly as it appears, and report it to your technical support representative
Explanation When the BMA microcode download command was issued, the given BMA microcode bundled in the image was not retrieved because it is null.
Recommended Action Copy the error message exactly as it appears, and report it to your technical support representative
Explanation The system ran out of available SDRAM buffer headers while attempting to carve buffers. This could be a cause of SDRAM buffer carve failure.
Recommended Action Copy the error message exactly as it appears, and report it to your technical support representative
Explanation The calculated SDRAM buffer size (in bytes, including header and data portions) is not within the given range. This could be a cause of SDRAM buffer carve failure.
Recommended Action Copy the error message exactly as it appears, and report it to your technical support representative.
Explanation The maximum number of SDRAM buffer headers is limited to a maximum number that has been exceeded. This could be a cause of SDRAM buffer carve failure.
Recommended Action Copy the error message exactly as it appears, and report it to your technical support representative.
Explanation The number of free queues allowed for SDRAM buffer carving has been exceeded. This could be a cause of SDRAM buffer carve failure.
Recommended Action Copy the error message exactly as it appears, and report it to your technical support representative.
Explanation The sum of percentages per SDRAM buffer size has exceeded 100. This could be a cause of SDRAM buffer carve failure.
Recommended Action Copy the error message exactly as it appears, and report it to your technical support representative.
Explanation The calculated sum of SDRAM to be carved is larger than the available SDRAM for carving. This could be a cause of SDRAM buffer carve failure.
Recommended Action Copy the error message exactly as it appears, and report it to your technical support representative.
Explanation The BMA quiesce-for-carve algorithm retrieved a bad jump vector mask return value. This message could indicate an error in the quiesce.
Recommended Action Copy the error message exactly as it appears, and report it to your technical support representative.
Explanation There are no more available free queues that can be used for SDRAM buffer carve. This could be a cause of SDRAM buffer carve failure.
Recommended Action Copy the error message exactly as it appears, and report it to your technical support representative.
Explanation This is an internal parameter error with one or more SDRAM buffer memory parameters: maximum buffer header count or SDRAM sizes (total, not available for carve, and available for carve).
Recommended Action Copy the error message exactly as it appears, and report it to your technical support representative.
Explanation The system ran out of Queue Manager elements, which are used for SDRAM buffer carving. This could be a cause of SDRAM buffer carve failure.
Recommended Action Copy the error message exactly as it appears, and report it to your technical support representative.
Explanation An error occurred during Queue Manager SRAM initialization. Reading one or more zeroed Queue Manager SRAM locations gave a non-zero result. Possible errors could be in head, tail, length, length threshold, buffer address, next queue element, or scratch RAM locations.
Recommended Action Copy the error message exactly as it appears, and report it to your technical support representative.
Explanation The BMA quiesce-for-carve algorithm waits an allotted time for line card queues to flush. One or more waits exceeded this allotted time. These queues are specific to the line card's ASICs. This error message might not actually indicate an error, but that the allotted time might not be sufficient and should be increased.
Recommended Action Copy the error message exactly as it appears, and report it to your technical support representative.
Explanation The system software detected an old version of the BMA.
Recommended Action Call your technical support for an upgraded version.
Explanation A card was either manufactured improperly, failed, or is newer than the software.
Recommended Action Replace the card or upgrade the software.
Explanation Initialization of the memory address failed.
Recommended Action Copy the error message exactly as it appears, and report it to your technical support representative.
Explanation The given memory location could not be read.
Recommended Action Copy the error message exactly as it appears, and report it to your technical support representative.
Explanation Initialization of the line card I/O registers failed.
Recommended Action Copy the error message exactly as it appears, and report it to your technical support representative.
Explanation No bytes were written to the given location.
Recommended Action Copy the error message exactly as it appears, and report it to your technical support representative.
Explanation The above packet was routed to an invalid queue. The data shown is the packet header.
Recommended Action Copy the error message exactly as it appears, and report it to your technical support representative.
Explanation An error occurred in the line card's L3FE ASIC (reg. information).
Recommended Action Copy the error message exactly as it appears, and report it to your technical support representative
Explanation An error occurred in the line card's L3FE ASIC.
Recommended Action Copy the error message exactly as it appears, and report it to your technical support representative
Explanation The system could not allocate a data buffer to contain contents of the given line card file that was downloaded. There may be insufficient DRAM.
Recommended Action Copy the error message exactly as it appears, and report it to your technical support representative.
Explanation For the GLC code download command, the checksum verification failed.
Recommended Action Copy the error message exactly as it appears, and report it to your technical support representative
Explanation For the GLC code program command, there is no downloaded code to program.
Recommended Action Copy the error message exactly as it appears, and report it to your technical support representative
Explanation An unknown BMA selector value was encountered.
Recommended Action Copy the error message exactly as it appears, and report it to your technical support representative.
Explanation This is test message for a software test.
Recommended Action Stop issuing the test gsr logger command.
Explanation This is test message for a software test.
Recommended Action Stop issuing the test gsr logger command.
Explanation This is test message for a software test.
Recommended Action Stop issuing the test gsr logger command.
Explanation This is test message for a software test.
Recommended Action Stop issuing the test gsr logger command.
Explanation This is test message for a software test.
Recommended Action Stop issuing the test gsr logger command.
Explanation This is test message for a software test.
Recommended Action Stop issuing the test gsr logger command.
Explanation This is test message for a software test.
Recommended Action Stop issuing the test gsr logger command.
Explanation This is test message for a software test.
Recommended Action Stop issuing the test gsr logger command.
ATM Cisco Express Forwarding (CEF) adjacency error messages
Explanation The line card CEF received an adjacency with the incorrect mac rewrite string. Packets forwarded to that adjacency will be dropped.
Recommended Action Copy the error message exactly as it appears, and report it to your technical support representative.
Explanation The line card CEF received an adjacency with the incorrect output_info field. Packets forwarded to that adjacency will be dropped.
Recommended Action Copy the error message exactly as it appears, and report it to your technical support representative.
Line card core dump error messages
Explanation The system just finished dumping a core file from a line card. It tried to close this file on the remote system and failed.
Recommended Action Debug network connections and user privileges.
Explanation The system wants to dump a core file to a remote system, but it is unable to open the remote file.
Recommended Action Ensure that the remote system is accessible and the protocol is set up correctly.
Explanation The system is trying to write a core dump file to a remote system. The file was opened, and an error occurred during a write to the file.
Recommended Action Check network and disk space available.
Explanation The system cannot allocate memory for the coredump subsystem.
Recommended Action Add more memory.
Explanation The NVGEN routine was called, but NVGEN was not set.
Recommended Action Gather information about the processes running on this GSR, including the traceback, and file a bug.
Explanation The RP received a core dump packet from a line card that should not be dumping core.
Recommended Action Gather information about the state of the line cards and file a bug.
Explanation You cannot run a line card coredump test for an RP.
Recommended Action Do not run a line card coredump test for an RP.
Explanation The exception linecard commands can only be used to configure exceptions on a line card. Configuring RP linecard exceptions is not allowed.
Recommended Action Use the exception command without linecard to configure RP core dumps.
Explanation The system is trying to write a core dump file to a remote system. It could not allocate memory to create the message that starts the dump on the line card.
Recommended Action Add memory.
Explanation The system is currently dumping a core file for this line card. You cannot modify core dump configuration during a dump.
Recommended Action Wait for the core dump to finish.
Explanation The RP received a core dump packet from a line card that the should not be dumping core.
Recommended Action Gather information about the state of the line cards and file a bug.
Explanation The system wants to write a core dump file to a remote system but it is unable to start a process to dump the file.
Recommended Action Gather information about the number of processes running, including the amount of memory in the system, and file a bug.
Explanation The system is trying to write a core dump file to a remote system. It could not create a queue to hold dump data coming from the line cards.
Recommended Action Add memory.
Explanation The system is trying to write a core dump file, but the RP timed out while waiting for data from the line card.
Recommended Action Gather information about the line card and file a bug.
Line card information error messages
Explanation The line card in the indicated slot crashed and sent a CRASH_START message to the RP. The RP is now waiting for the rest of the crash information from the line card to be sent via the MBUS (stack trace, context, version, and so forth). This should happen in a few milliseconds after receiving the CRASH_START message. The RP software has not otherwise been notified of the line card crash---that will happen after all the crash information has been sent to the RP. In the unlikely event that the subsequent crash information messages are not received by the RP within a reasonable time limit (perhaps 10 seconds), the RP will print a TIMEOUT error message indicating such and tell the rest of the RP software that the line card has crashed.
Recommended Action Report this defect with as much information about the line card as possible, including the output of the show context summary, show context slot, and show tech-support commands, as well as the show tech-support command output from the RP.
Explanation The line card crash information subsystem on the RP was called from the MBUS subsystem with an invalid DEVICE identifier. The DEVICE in this case is supposed to be the slot number of the line card, but it was out of range. This indicates a software defect in the system.
Recommended Action Report this defect with as much information about the MBUS subsystem as possible. There is no adverse effect to the RP---it ignores the bad callback and continues. If the problem persists, reboot the router. It is unlikely but possible that the problem is the result of bad MBUS hardware somewhere in the system (most likely the RP MBUS module).
Explanation The line card crash information subsystem for the line card indicated it is in an unknown state. This is because of a software defect in that subsystem.
Recommended Action Report this defect with as much information about the MBUS subsystem and the line card crash information subsystem as possible.
Explanation The RP could not allocate memory for line card crash data structures at startup time. By itself, this is not a serious problem, but the underlying memory shortage at startup time will probably prevent the router from running well, if at all.
Recommended Action Debug the memory shortage problem and add more memory if necessary.
Explanation The RP could not allocate memory for one or more buffers to hold line card crash information at startup time. By itself, this is not a serious problem, but the underlying memory shortage at startup time will probably prevent the router from running well, if at all.
Recommended Action Debug the memory shortage problem and add more memory if necessary. Possibly reduce the size of or the number of crash information buffers allocated per line card to hold crash information. (As of this writing, it is not known whether the size or number will be configurable.)
Explanation When creating the crash complete process for the crash information subsystem, the create_process call failed. The failure is probably because of a software defect or hardware failure and should only occur during initialization.
Recommended Action Reboot the system. If the condition persists on subsequent reloads of the system, a bug should be filed and the system should be reloaded with a different image.
Explanation The crash information complete timer expired. When a line card crashes, it sends information to the RP for debugging and analysis. When the START OF CRASH message is received, a timer is set for approximately 10 seconds. The line card has 10 seconds to send all the crash information to the RP. This is not a crash dump---it is a small amount of information that usually includes context, stack trace, and so forth. It is less than 8K bytes of information. If an END OF CRASH information message is not received before the timer goes off, the crash information record is closed (containing partial information), this message is displayed, and the rest of the system is notified that the line card crashed (at which point it is probably reloaded). If the line card sends more crash information after the timer goes off and before the system resets the line card, additional UNXMSG error messages might be displayed.
Recommended Action No action is required specifically because this message was displayed; however, because the line card crashed, there might be other defects to report. If this message is seen without a line card crashing, report this message and the output of the show tech-support on the RP and on the line card that did not crash but was mentioned in this error message.
Explanation A line card crashed and sent crash information to the RP. The RP received a CRASH RECORD START message that indicated the data would be so many bytes long. Before that amount of bytes were received, the RP received another CRASH RECORD START message indicating the start of another record. The current record is marked as truncated, and the next record is received, but the anomaly is noted in this error message. This is a problem, but because what started this process was a line card crashing, this might only be a symptom of another underlying problem.
Recommended Action Report this defect with as much information about the MBUS subsystem and the line card crash information subsystem as possible.
Explanation The line card crash information subsystem received an unexpected message for the state it is in. The state and message type are given in the error message. This does not have any adverse effect on the RP since it ignores and/or recovers from this occurrence. The sender of this message is a line card that is crashing. The source of the crash on the line card is more interesting. If this occurs without a line card crash, it is because of a stray/errant MBUS message that should be pursued. This problem could also be the result of a dropped MBUS message.
Recommended Action Find the source of the crash on the line card if one was crashing when the message occurred. If no line card crashed, report this defect with as much information about the MBUS subsystem and the line card crash information subsystem as possible. If this message recurs, reboot the router to remove this message.
Line card log error messages
Explanation The line card crash info subsystem on the RP was called from the MBUS subsystem with an invalid DEVICE identifier. The DEVICE in this case is supposed to be the slot number of the line card, but it was out of range. This indicates a software defect in the system.
Recommended Action Report this defect with as much information about the MBUS subsystem as possible. There is no adverse effect to the RP---it ignores the bad callback and continues. If the problem recurs, reboot the router. It is unlikely but possible that the problem is because of bad MBUS hardware somewhere in the system (most likely the RP MBUS module).
Explanation The line card logger subsystem for the indicated line card is not in the state expected for the message it received. This is probably because of a software defect in that subsystem. This message could also be caused by a dropped MBUS message.
Recommended Action Report this defect with as much information about the MBUS subsystem and the line card logger subsystem as possible.
Explanation The RP part of the line card logger server has received a log start message that is larger than the maximum log buffer allows. This is probably caused by a software defect.
Recommended Action Report this defect with as much information about the MBUS subsystem and the line card logger subsystem as possible.
Explanation The RP part of the line card logger server received more text for a message than the start message indicated. This is probably caused by a software defect.
Recommended Action Report this defect with as much information about the MBUS subsystem and the line card logger subsystem as possible.
Explanation The RP part of the line card logger server received more text for a message than will fit in the message log buffer. This is probably caused by a software defect.
Recommended Action Report this defect with as much information about the MBUS subsystem and the line card logger subsystem as possible.
Line Card Physical Layer Interface Module error messages
Explanation A NULL POS line card instance was found.
Recommended Action Copy the error message exactly as it appears on the console or in the system log. Issue the execute-on slot number show controller command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the execute-on slot number show controller output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The number of interfaces exceeds the maximum limit for this line card.
Recommended Action Copy the error message exactly as it appears on the console or in the system log. Issue the show version, show gsr, show diags, show interfaces, execute-on slot number show controller, and execute-on slot number show subsys commands to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the output of these commands, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation Undefined command received for this interface
Recommended Action Copy the error message exactly as it appears on the console or in the system log. Issue the show ipc status command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show ipc status output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An undefined GSR card type was found.
Recommended Action Copy the error message exactly as it appears on the console or in the system log. Issue the show version, show gsr, show diags, show interfaces, and execute-on slot number show subsys commands to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the output of these commands, call your Cisco technical support representative and provide the representative with the gathered information.
Line Card Packet-Over-SONET error messages
Explanation POS BMA engine hardware errors occurred.
Recommended Action Copy the error message exactly as it appears on the console or in the system log. Run diagnostics on the line card in the indicated slot. If diagnostics pass, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation A parity error occurred on the POS ASIC BMA engine.
Recommended Action Copy the error message exactly as it appears on the console or in the system log. Run diagnostics on the line card in the indicated slot. If diagnostics pass, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The line card POS ASIC and framer initialization failed.
Recommended Action Copy the error message exactly as it appears on the console or in the system log. If you cannot determine the nature of the error from the error message text, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The line card POS link report process received an unexpected event.
Recommended Action Copy the error message exactly as it appears on the console or in the system log. Issue the show subsys command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show subsys output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The line card POS link report process cannot be created.
Recommended Action Copy the error message exactly as it appears on the console or in the system log. Issue the show subsys command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show subsys output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The line card POS link report process stopped working.
Recommended Action Copy the error message exactly as it appears on the console or in the system log. Issue the show subsys and show memory summary commands to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the output from these commands, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation POS engine hardware errors occurred.
Recommended Action Copy the error message exactly as it appears on the console or in the system log. Run diagnostics on the line card in the indicated slot. If diagnostics pass, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The software was trying to shutdown the Rx POS engine. The POS engine refused to shutdown and the software timed out.
Recommended Action Copy the error message exactly as it appears on the console or in the system log. Run diagnostics on the line card in the indicated slot. If diagnostics pass, issue the execute-on slot number show controller pos registers command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the output of this command, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation A parity error occurred on POS ASIC SRAM.
Recommended Action Copy the error message exactly as it appears on the console or in the system log. Run diagnostics on the line card in the indicated slot. If diagnostics pass, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The software was trying to shutdown the Tx POS engine. The POS engine refused to shutdown and the software timed out
Recommended Action Copy the error message exactly as it appears on the console or in the system log. Run diagnostics on the line card in the indicated slot. If diagnostics pass, issue the execute-on slot number show controller pos registers command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the output of this command, call your Cisco technical support representative and provide the representative with the gathered information.
LAN Emulation Server/Fiber Distributed Data Interface error message
Explanation The router does not have enough I/O memory to support a FDDI interface. The FDDI interface requires at least 4MB of I/O memory.
Recommended Action Install the required amount of I/O memory. For maximum performance, Cisco recommends installing 8Mb of I/O memory for a single FDDI NIM, and 16MB of I/O memory if 2 FDDI NIMs are installed. With 4MB of I/O memory the system will create 256 FDDI buffers for one FDDI interface or 384 buffers for two FDDI interfaces. With 8MB of I/O memory the system will create 512 FDDI buffers for either one or two FDDI interfaces. With 16MB of I/O memory the system will create 512 FDDI buffers for one FDDI interface or 1024 buffers for two FDDI interfaces.
LAN extension error messages
Explanation The serial line went down, and the specified command was not sent to the LAN Extender.
Recommended Action Determine why the serial line went down. For example, was the cable was pulled, or the LAN Extender powered off? The command will automatically be re-sent once the serial interface is operational.
Explanation The LAN Extender could not process the command from the host router. Possible causes are as follows. The LAN Extender ran out of memory. The message from the host router is malformed. A request to write Flash memory occurred while the LAN Extender was busy writing Flash memory for a previous request. The size of a file to be downloaded is greater than the amount of Flash memory available.
Recommended Action If the command was copy tftp lex unit-number or copy flash lex unit-number, ensure that the correct file (a FLEX image file) is specified. Only a single copy request can be handled at one time. If the problem was caused by a temporary out-of-memory condition on the LAN Extender, re-enter the command.
Explanation The LAN Extender did not recognize the code for the specified remote command. This might occur if the user is running old LAN Extender software with newer host router software that has support for new LEX remote commands.
Recommended Action Update the LAN Extender software.
Explanation The host router re-sent the given message as many times as specified in the lex retry-count command configuration variable, without receiving an acknowledgment from the LAN Extender. At this point, the host router gives up trying to send this particular remote command message.
Recommended Action Use the LEDs on the LAN Extender to determine if it is operational. Confirm that the lex timeout configuration command is set appropriately for the speed of the link.
Line Protocol error message
Explanation The data-link level line protocol changed state.
Recommended Action No action is required.
Data link error messages
Explanation The lower-level software was unable to write a MAC header for a datagram. A probable cause is configuration error.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, and report it to your Cisco technical support representative.
Explanation An attempt to map a network level address to a MAC level address failed.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, and report it to your Cisco technical support representative.
Explanation An internal software error occurred.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An internal software error occurred. The high-level system code tried to use an unimplemented entry point with the virtual interface descriptor block (IDB) driver.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, and report it to your Cisco technical support representative.
Explanation BERT is completed for this interface.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, and report it to your Cisco technical support representative.
Explanation A serial interface has been configured with an unknown encapsulation.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, and report it to your Cisco technical support representative.
Explanation An interface's IP address was successfully learned dynamically through BootP. The first address is the learned IP address. The second IP address is the IP address of the BootP server that provided the information.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, and report it to your Cisco technical support representative.
Explanation An FCIT running in nonencapsulating transparent mode detected an FDDI bridge running in encapsulation mode on the same fiber. This is an unstable situation and should be corrected. The incoming interface is displayed, along with the FDDI MAC address in standard form.
Recommended Action Upgrade the errant interface to full-transparent mode. Copy the error message exactly as it appears, and report it to your Cisco technical support representative.
Explanation The interface hardware changed state.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, and report it to your Cisco technical support representative.
Explanation A software or hardware error occurred.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, and report it to your Cisco technical support representative.
Explanation An internal software error occurred.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation A state change occurred on the FDDI ring.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, and report it to your Cisco technical support representative.
Explanation An internal software error occurred.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An internal software error occurred.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation An internal software inconsistency occurred.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, and report it to your Cisco technical support representative.
Explanation The interface entered or exited loopback.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, and report it to your Cisco technical support representative.
Explanation An addressing inconsistency occurred.
Recommended Action Ensure that this address is unique, or specify MAC addresses for commands such as novell routing that allow the use of this address as a default.
Explanation An internal software error occurred.
Recommended Action Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support output, call your Cisco technical support representative and provide the representative with the gathered information.
Explanation The Reverse Address Resolution Protocol (RARP) resolved an IP address.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, and report it to your Cisco technical support representative.
Explanation The interface entered or exited a remote loopback.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, and report it to your Cisco technical support representative.
Explanation The Serial Line Address Resolution Protocol (SLARP) resolved an IP address.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, and report it to your Cisco technical support representative.
Explanation An internal software error occurred.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, and report it to your Cisco technical support representative.
Explanation An output packet was detected that was smaller than the minimum allowable datagram size. An error in another driver or an error in the system software probably triggered this error message.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, and report it to your Cisco technical support representative.
Explanation The interface hardware went either up or down.
Recommended Action If the state change was unexpected, confirm the configuration settings for the interface.
Logical Link Control, type 2 error message
Explanation An internal software error was found. A software component is trying to use LLC2 structures that do not exist.
Recommended Action Record the configuration and any information that would be useful in re-creating the error and call your technical support representative.
Linked list facility error messages
Explanation An internal inconsistency was detected when an attempt was made to remove an item from a list not on the list.
Recommended Action Copy the message exactly as it appears and report it to your technical service representative.
Explanation An internal inconsistency was detected when an attempt was made to add an item to a list already on the list.
Recommended Action Copy the message exactly as it appears and report it to your technical service representative.
LAN network manager system error messages
Explanation A LAN network manager system error occurred.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, and report it to your Cisco technical support representative.
Explanation A LAN network manager system error occurred.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, and report it to your Cisco technical support representative.
Explanation A LAN network manager system error occurred.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, and report it to your Cisco technical support representative.
Explanation A LAN network manager system error occurred.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, and report it to your Cisco technical support representative.
Explanation A LAN network manager system error occurred.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, and report it to your Cisco technical support representative.
Explanation A LAN network manager system error occurred.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, and report it to your Cisco technical support representative.
Explanation A LAN network manager system error occurred.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, and report it to your Cisco technical support representative.
Explanation A LAN network manager system error occurred.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, and report it to your Cisco technical support representative.
Explanation A LAN network manager system error occurred.
Recommended Action Copy the error message exactly as it appears on the console or in the system log, and report it to your Cisco technical support representative.
Line printer daemon error message
Explanation An internal buffer did not have enough room to add all the necessary carriage returns to a packet of LPD data destined for a printer configured with a newline-convert command. This message is unlikely to occur with a file containing valid data.
Recommended Action Check the file being printed to see whether it contains valid, printable data.
|
|