This chapter describes how to configure voice ports for both the Cisco 3600 series (for Voice over IP) and for the Cisco MC3810 (for Voice over Frame Relay, Voice over ATM, and Voice over HDLC). For a description of the voice port commands, refer to the "Voice Port Commands" chapter in the Voice, Video, and Home Applications Command Reference.
The Cisco 3600 currently provides only analog voice ports for its implementation of Voice over IP. The type of signaling associated with these analog voice ports depend on the interface module installed into the device. The Cisco 3600 series router supports either a two-port or four-port voice network module (VNM); VNMs can hold either two or four voice interface cards (VICs).
Each VIC is specific to a particular signaling type; therefore, VICs determine the type of signaling for the voice ports on that particular VNM. This means that even though VNMs can hold multiple VICs, each VIC on a VNM must conform to the same signaling type. For more information about the physical characteristics of VNMs and VICs or how to install them, refer to the installation document, Voice Network Module and Voice Interface Card Configuration Note, that came with your VNM.
Voice ports on the Cisco 3600 series support three basic voice signaling types:
In general, voice port commands define the characteristics associated with a particular voice port signaling type. Under most circumstances, the default voice port command values are adequate to configure FXO and FXS ports to transport voice data over your existing IP network. Because of the inherent complexities involved with PBX networks, E&M ports might need specific voice port values configured, depending on the specifications of the devices in your telephony network.
Perform the following tasks to configure the voice ports on the Cisco 3600 series:
Under most circumstances the default voice port values are adequate for both FXO and FXS voice ports. If you need to change the default configuration for these voice ports, perform the following tasks. The first two tasks are required; the third task is optional.
1. Identify the voice port and enter the voice-port configuration mode.
2. Configure the following mandatory voice-port parameters:
(a) Dial type (FXO only)
(b) Signal type
(c) Call progress tone
(d) Ring frequency (FXS only)
(e) Ring number (FXO only)
3. Configure one or more of the following optional voice-port parameters:
(a) PLAR connection mode
(b) Music-threshold
(c) Description
(d) Comfort noise (if VAD is activated---VAD is a dial peer command)
To configure FXO and FXS voice ports, use the following commands beginning in privileged EXEC mode:
| Step | Command | Purpose | ||
|---|---|---|---|---|
| configure terminal | |||
| voice-port slot-number/subunit-number/port | Identify the voice port you want to configure and enter voice-port configuration mode. | ||
| dial-type {dtmf | pulse} | (For FXO ports only) Select the appropriate dial type for out-dialing. | ||
| signal {loop-start | ground-start} | Select the appropriate signal type for this interface. | ||
| cptone country | Select the appropriate voice call progress tone for this interface. The default for this command is us. For a list of supported countries, refer to the Voice, Video, and Home Applications Command Reference. | ||
| ring frequency {25 | 50} | (For FXS ports only) Select the appropriate ring frequency (in Hertz) specific to the equipment attached to this voice port. | ||
| ring number number | (For FXO ports only) Specify the maximum number of rings to be detected before answering a call. | ||
| connection plar string | (Optional) Specify the private line auto ringdown (PLAR) connection, if this voice port is used for a PLAR connection. The string value specifies the destination telephone number. | ||
| music-threshold number | (Optional) Specify the threshold (in decibels) for on-hold music. Valid entries are from -70 to -30. | ||
| description string | (Optional) Attach descriptive text about this voice port connection. | ||
| comfort-noise | (Optional) Specify that background noise will be generated. |
You can check the validity of your voice-port configuration by performing the following tasks:
Depending on the specifics of your particular network, you may need to adjust voice parameters involving timing, input gain, and output attenuation for FXO or FXS voice ports. Collectively, these commands are referred to as voice-port tuning commands.
To configure voice-port tuning for FXO and FXS voice ports, perform the following tasks:
1. Identify the voice port and enter the voice-port configuration mode.
2. For each of the following parameters, select the appropriate value:
(a) Input gain
(b) Output attenuation
(c) Echo cancel coverage
(d) Non-linear processing
(e) Initial digit timeouts
(f) Interdigit timeouts
(g) Timing other than timeouts
To fine-tune FXO or FXS voice ports, use the following commands beginning in privileged EXEC mode:
| Step | Command | Purpose | ||
|---|---|---|---|---|
| configure terminal | |||
| voice-port slot-number/subunit-number/port | Identify the voice-port you want to configure and enter voice-port configuration mode. | ||
| input gain value | Specify (in decibels) the amount of gain to be inserted at the receiver side of the interface. Acceptable values are from -6 to 14. | ||
| output attenuation value | Specify (in decibels) the amount of attenuation at the transmit side of the interface. Acceptable values are from 0 to 14. | ||
| echo-cancel enable | Enable echo-cancellation of voice that is sent out the interface and received back on the same interface. | ||
| echo-cancel coverage value | Adjust the size (in milliseconds) of the echo-cancel. Acceptable values are 16, 24, and 32. | ||
| non-linear | Enable non-linear processing, which shuts off any signal if no near-end speech is detected. (Non-linear processing is used with echo-cancellation.) | ||
| timeouts initial seconds | Specify the number of seconds the system will wait for the caller to input the first digit of the dialed digits. Valid entries for this command are from 0 to 120. | ||
| timeouts interdigit seconds | Specify the number of seconds the system will wait (after the caller has input the initial digit) for the caller to input a subsequent digit. Valid entries for this command are from 0 to 120. | ||
| timing digit milliseconds | If the voice-port dial type is DTMF, configure the DTMF digit signal duration. The range of the DTMF digit signal duration is from 50 to 100. The default is 100. | ||
| timing inter-digit milliseconds | |||
| timing pulse-digit milliseconds | |||
| timing pulse-inter-digit milliseconds
|
Unlike FXO and FXS voice ports, the default E&M voice-port parameters most likely will not be sufficient to enable voice data transmission over your IP network. E&M voice-port values must match those specified by the particular PBX device to which it is connected.
To configure an E&M voice port, perform the following tasks. The first two tasks are required; the third task is optional.
1. Identify the voice port and enter the voice-port configuration mode.
2. For each of the following required parameters, select the appropriate parameter value:
(a) Dial type
(b) Signal type
(c) Call progress tone
(d) Operation
(e) Type
(f) Impedance
3. Select one or more of the following optional parameters:
(a) Connection mode
(b) Music-threshold
(c) Description
(d) Comfort tone (if VAD is activated)
To configure E&M voice ports, use the following commands beginning in privileged EXEC mode:
| Step | Command | Purpose | ||
|---|---|---|---|---|
| configure terminal | |||
| voice-port slot-number/subunit-number/port | Identify the voice port you want to configure and enter voice-port configuration mode. | ||
| dial-type {dtmf | pulse} | Select the appropriate dial type for out-dialing. | ||
| signal {wink-start | immediate | delay-dial} | Select the appropriate signal type for this interface. | ||
| cptone {australia | brazil | china | finland | france | germany | japan | northamerica | unitedkingdom} | Select the appropriate voice call progress tone for this interface. | ||
| operation {2-wire | 4-wire} | Select the appropriate cabling scheme for this voice port. | ||
| type {1 | 2 | 3 | 5} | Select the appropriate E&M interface type. Type 1 indicates the following lead configuration:
Type 2 indicates the following lead configuration:
Type 3 indicates the following lead configuration:
Type 5 indicates the following lead configuration:
| ||
| impedance {600c | 600r | 900c | complex1 | complex2} | Specify a terminating impedance. This value must match the specifications from the telephony system to which this voice port is connected. | ||
| connection plar string | (Optional) Specify the private line auto ringdown (PLAR) connection, if this voice port is used for a PLAR connection. The string value specifies the destination telephone number. | ||
| music-threshold number | (Optional) Specify the threshold (in decibels) for on-hold music. Valid entries are from -70 to -30. | ||
| description string | (Optional) Attach descriptive text about this voice port connection. | ||
| comfort-noise | (Optional) Specify that background noise will be generated. |
You can check the validity of your voice-port configuration by performing the following tasks:
Depending on the specifics of your particular network, you may need to adjust voice parameters involving timing, input gain, and output attenuation for E&M voice ports. Collectively, these commands are referred to as voice-port tuning commands.
To configure voice-port tuning for E&M voice ports, perform the following tasks:
1. Identify the voice port and enter the voice-port configuration mode.
2. For each of the following parameters, select the appropriate value:
(a) Input gain
(b) Output attenuation
(c) Echo cancel coverage
(d) Non-linear processing
(e) Initial digit timeouts
(f) Interdigit timeouts
(g) Timing other than timeouts
To fine-tune E&M voice ports, use the following commands beginning in privileged EXEC mode:
| Step | Command | Purpose | ||
|---|---|---|---|---|
| configure terminal | |||
| voice-port slot-number/subunit-number/port | Identify the voice port you want to configure and enter voice-port configuration mode. | ||
| input gain value | Specify (in decibels) the amount of gain to be inserted at the receiver side of the interface. Acceptable values are from -6 to 14. | ||
| output attenuation value | Specify (in decibels) the amount of attenuation at the transmit side of the interface. Acceptable values are from 0 to 14. | ||
| echo-cancel enable | Enable echo-cancellation of voice that is sent out the interface and received back on the same interface. | ||
| echo-cancel coverage value | Adjust the size (in milliseconds) of the echo-cancel. Acceptable values are 16, 24, and 32. | ||
| non-linear | Enable non-linear processing, which shuts off any signal if no near-end speech is detected. (Non-linear processing is used with echo-cancellation.) | ||
| timeouts initial seconds | Specify the number of seconds the system will wait for the caller to input the first digit of the dialed digits. Valid entries for this command are from 0 to 120. | ||
| timeouts interdigit seconds | Specify the number of seconds the system will wait (after the caller has input the initial digit) for the caller to input a subsequent digit. Valid entries for this command are from 0 to 120. | ||
| timing clear-wait milliseconds
| Specify the minimum amount of time between the inactive seizure signal and the call being cleared. Valid entries for clear-wait are from 200 to 2000 milliseconds. | ||
| timing delay-duration milliseconds
| Specify the delay signal duration for delay dial signaling. Valid entries for delay-duration are from 100 to 5000 milliseconds. | ||
| timing delay-start milliseconds
| Specify the minimum delay time from outgoing seizure to outdial address. Valid entries for delay-start are from 20 to 2000 milliseconds. | ||
| timing dial-pulse min-delay milliseconds
| Specify the time between generation of wink-like pulses. Valid entries for dial-pulse min-delay are from 0 to 5000 milliseconds. | ||
| timing digit milliseconds
| If the voice-port dial type is DTMF, configure the DTMF digit signal duration.Valid entries for digit are from 50 to 100 milliseconds. | ||
| timing inter-digit milliseconds
| If the voice-port dial type is DTMF, specify the DTMF inter-digit duration. Valid entries for inter-digit are from 50 to 500 milliseconds. | ||
| timing pulse pulse-per-second
| If the voice-port dial type is pulse, specify the pulse dialing rate. Valid entries for pulse are from 10 to 20 pulses per second. | ||
| timing pulse-inter-digit milliseconds
| If the voice-port dial type is pulse, specify the pulse dialing inter-digit timing. Valid entries for pulse-inter-digit are 100 to 1000 milliseconds. | ||
| timing wink-duration milliseconds
| Specify the maximum wink signal duration. Valid entries for wink-duration are from 100 to 400 milliseconds. | ||
| timing wink-wait milliseconds
| Specify the maximum wink-wait duration for a wink start signal. Valid entries for wink-wait are from 100 to 5000 milliseconds. |
After you have configured the voice port, you need to activate the voice port to bring it online. In fact it is a good idea to cycle the port---meaning to shut the port down and then bring it online again.
To activate a voice port, use the following commands in voice-port configuration mode:
| Command | Purpose |
|---|---|
no shutdown | Activate the voice port. |
To cycle a voice port, use the following command in voice-port configuration mode:
| Step | Command | Purpose | ||
|---|---|---|---|---|
| shutdown | Deactivate the voice port. | ||
| voice-port slot-number/subunit-number/port | Identify the voice port you want to activate and enter the voice-port configuration mode. | ||
| no shutdown | Activate the voice port. |
The Cisco MC3810 voice ports provide support for three basic voice signaling formats:
In general, voice-port commands define the characteristics associated with a particular voice-port signaling type. Under most circumstances, the default voice-port command values are adequate to configure FXO and FXS ports to transport voice data using the Cisco MC3810. Because of the inherent complexities involved with PBX networks, E&M ports might need specific voice-port values configured, depending on the specifications of the devices in your telephony network.
Table 10 lists the valid slot and port numbers for the different voice interfaces.
| Interface Type | Slot | Valid Port Numbers |
|---|---|---|
Analog voice module (AVM) | 1 | 1-6 |
Digital voice module (DVM) | 1 | Digital T1: 1-24 Digital E1: 1-15 and 17-31 |
Multiflex Trunk (MFT) | 0 | Digital T1: 1-24 Digital E1: 1-15 and 17-31 |
Perform the following tasks to configure the voice ports on the Cisco MC3810:
Under most circumstances the default voice-port values are adequate for both FXO and FXS voice ports. If you need to change the default configuration for these voice ports, perform the following tasks. The first two tasks are required; the third task is optional.
1. Identify the voice port and enter the voice-port configuration mode.
2. Configure the following mandatory voice-port parameters:
(a) Connection
(b) Dial type
(c) Signal type
(d) CODEC
(e) Call progress tone
3. Configure one or more of the following optional voice-port parameters:
(a) Description
(b) VAD
(c) Comfort noise (if VAD is activated)
To configure FXO and FXS voice ports, use the following commands beginning in privileged EXEC mode:
| Step | Command | Purpose | ||
|---|---|---|---|---|
| voice-port slot/port | Enter voice-port configuration mode. The slot number for analog voice ports on the Cisco MC3810 is always 1. There is no port 0 for voice ports. | ||
| connection {plar | tie-line | plar-opx} string | Configure the voice-port connection mode type and the destination telephone number. The plar value is used for Private Line Auto Ringdown (PLAR) connections. The tie-line value is used for a tie-line connection to a PBX. The plar-opx value is used for PLAR Off-Premises eXtension, to allow the local voice port to provide a local response before the remote voice port receives an answer. | ||
| dial-type {pulse | dtmf} | Configure the voice-port dial-type. The default is dtmf (FXO only). | ||
| signal {loop-start | ground-start} | Configure the signaling type for analog FXO and FXS voice ports. The default is loop-start. | ||
| codec {g729r8 | g729ar8 | g726r32 | | Configure the voice-port compression mode.The g729ar8 value is the default and is recommended. The g729ar8 compression mode can support a maximum of 24 simultaneously active on-net voice calls while the g729r8 value can only support a maximum of 12. The g729 compression modes have a nominal data rate of 8 kbps. | ||
| compand-type {u-law | a-law} | Configure the companding standard used to convert between analog and digital signals in PCM systems. This command applies to digital voice-ports only. | ||
| cptone country | Configure the appropriate call progress tone for the local region. The default for this command is northamerica. For a list of supported countries, refer to the Voice, Video, and Home Applications Command Reference. | ||
| description string | (Optional) Enter a string description for the voice port. The string describes the voice port in displays. You can use the description command to note the voice port's location or use. | ||
| vad | (Optional) Enable voice activity detection (VAD). | ||
| voice confirmation-tone | (Optional) If the voice port is configured for connection plar-opx for Off-Premises eXtension, disable the two-beep confirmation tone that a caller hears when picking up the handset. |
You can check the validity of your voice-port configuration by performing the following tasks:
Depending on the specifics of your particular network, you may need to adjust voice parameters involving timing, input gain and output attenuation for FXO or FXS voice ports. Collectively, these commands are referred to as voice-port tuning commands.
To configure voice-port tuning applicable for both FXO and FXS voice ports, perform the following tasks:
1. Identify the voice port and enter the voice-port configuration mode.
2. For each of the following parameters, select the appropriate value:
(a) Input gain
(b) Output attenuation
(c) Echo cancel coverage
(d) Initial digit timeouts
(e) Interdigit timeouts
(f) Timing other than timeouts
(g) Impedance (FXO voice ports only)
(h) Ring number (FXO voice ports only)
(i) Ring frequency (FXS voice port only)
(j) Ring cadence (FXS voice port only)
To fine-tune FXO or FXS voice ports, perform the following steps beginning in privileged EXEC mode:
| Step | Command | Purpose | ||
|---|---|---|---|---|
| configure terminal | |||
| voice-port slot/port | Identify the voice port you want to configure and enter voice-port configuration mode. | ||
| input gain value | Specify (in decibels) the amount of gain to be inserted at the receiver side of the interface. Acceptable values are from -6 to 14. | ||
| output attenuation value | Specify (in decibels) the amount of attenuation at the transmit side of the interface. Acceptable values are from 0 to 14. | ||
| echo-cancel enable | Enable echo-cancellation of voice that is sent out the interface and received back on the same interface. | ||
| echo-cancel coverage value | Adjust the size (in milliseconds) of the echo-cancel. Acceptable values are 16, 24, and 32. | ||
| timeouts initial seconds
| |||
| timeouts interdigit seconds
| Configure the interdigit timeout value. The timeouts interdigit value specifies the number of seconds the system waits (after the caller has input the initial digit) for the caller to input a subsequent digit of the dialed digits. The default is 10 seconds. | ||
| timing digit milliseconds
| If the voice-port dial type is DTMF, configure the DTMF digit signal duration. The range of the DTMF digit signal duration is from 50 to 100 milliseconds. The default is 100. | ||
| timing inter-digit milliseconds | |||
| timing pulse-digit milliseconds
| |||
| timing pulse-inter-digit milliseconds
| |||
| impedance {600r | 600c | 900r | 900c}
| (For FXO ports only) Configure the impedance. The default is 600 ohms real. | ||
| ring number number | (For FXO ports only) Configure the number of rings detected before a connection is closed on the FXO port. | ||
| ring frequency number | (For FXS ports only) Specify the local ring frequency for the FXS voice port. The number value should be set to either 20 or 30. | ||
| ring cadence [on1 | off1] [on2 | off2] [on3 | off3] [on4 | off4] [on5 | off5] [on6 | off6] | (For FXS only) Specify the local ring cadence for the FX voice port. Using this command, specify the on and off pulses for the ring. The ring cadence differs depending on the local region. The units are in 100-millisecond units. |
Unlike FXO and FXS voice ports, the default E&M voice-port parameters most likely will not be sufficient to enable voice data transmission over your network.
To configure an E&M voice port on the Cisco MC3810, perform the following tasks. The first two tasks are required; the third task is optional.
1. Identify the voice port and enter the voice-port configuration mode.
2. Configure the appropriate value for each of the following required parameters:
(a) Connection
(b) Dial type
(c) Cabling scheme
(d) Interface type
(e) Signal type
(f) CODEC
(g) Call progress tone
3. Configure one or more of the following optional parameters:
(a) Description
(b) VAD
(c) Comfort noise (if VAD is activated)
To configure E&M voice ports, use the following commands beginning in privileged EXEC mode:
| Step | Command | Purpose | ||
|---|---|---|---|---|
| configure terminal | |||
| voice-port slot/port | Identify the voice port you want to configure and enter voice-port configuration mode. | ||
| connection {plar | tie-line | plar-opx} string | Configure the voice-port connection mode type and the destination telephone number. The plar value is used for Private Line Auto Ringdown (PLAR) connections. The tie-line value is used for a tie-line connection to a PBX. The plar-opx value is used for PLAR Off-Premises eXtension, to allow the local voice port to provide a local response before the remote voice port receives an answer. | ||
| dial-type dtmf | Select the appropriate dial type for out-dialing. For E&M voice ports, the only available choice is DTMF. | ||
| operation {2-wire | 4-wire} | Select the appropriate cabling scheme for this voice port. | ||
| type {1 | 2 | 3 | 5} | Select the appropriate E&M interface type. Type 1 indicates the following lead configuration:
Type 2 indicates the following lead configuration:
Type 3 indicates the following lead configuration:
Type 5 indicates the following lead configuration:
| ||
| signal {wink-start | immediate | delay-dial} | Configure the signaling type for E&M voice ports. The default is wink-start. | ||
| codec {g729r8 | g729ar8} | Configure the voice-port compression mode.The g729ar8 value is the default and is recommended. The g729ar8 compression mode can support a maximum of 24 simultaneously active on-net voice calls while the g729r8 value can only support a maximum of 12. Both compression modes have a nominal data rate of 8 kbps. | ||
| compand-type {u-law | a-law} | Configure the companding standard used to convert between analog and digital signals in PCM systems. This command applies to digital voice-posts only. | ||
| cptone country | Configure the appropriate call progress tone for the local region. The default for this command is northamerica. For a list of supported countries, refer to the Voice, Video, and Home Applications Command Reference. | ||
| description string | (Optional) Attach descriptive text about this voice port connection. | ||
| vad | (Optional) Enable voice activity detection (VAD). | ||
| voice confirmation-tone | (Optional) If the voice port is configured for connection plar-opx for Off-Premises eXtension, disable the two-beep confirmation tone that a caller hears when picking up the handset. |
You can check the validity of your voice-port configuration by performing the following tasks:
Depending on the specifics of your particular network, you may need to adjust voice parameters involving timing, input gain and output attenuation for E&M voice ports. Collectively, these commands are referred to as voice-port tuning commands.
To configure voice-port tuning for E&M voice ports, perform the following tasks:
1. Identify the voice port and enter the voice-port configuration mode.
2. Select the appropriate value for each of the following parameters:
(a) Input gain
(b) Output attenuation
(c) Echo cancel coverage
(d) Non-linear processing
(e) Initial digit timeouts
(f) Interdigit timeouts
(g) Timing other than timeouts
To fine-tune E&M voice ports, use the following commands beginning in privileged EXEC mode:
| Step | Command | Purpose | ||
|---|---|---|---|---|
| configure terminal | |||
| voice-port slot/port | Identify the voice port you want to configure and enter voice-port configuration mode. | ||
| input gain value | Specify (in decibels) the amount of gain to be inserted at the receiver side of the interface. Acceptable values are from -6 to 14. | ||
| output attenuation value | Specify (in decibels) the amount of attenuation at the transmit side of the interface. Acceptable values are from 0 to 14. | ||
| echo-cancel enable | Enable echo-cancellation of voice that is sent out the interface and received back on the same interface. | ||
| echo-cancel coverage value | Adjust the size (in milliseconds) of the echo-cancel. Acceptable values are 16, 24, and 32. | ||
| non-linear | Enable non-linear processing, which shuts off any signal if no near-end speech is detected. (Non-linear processing is used with echo-cancellation.) | ||
| timeouts initial seconds | Configure the initial timeout value. The initial timeout value specifies the number of seconds the system waits for the caller to input the first digit of the dialed digits. The default is 10 seconds. | ||
| timeouts interdigit seconds | Configure the interdigit timeout value. The timeouts interdigit value specifies the number of seconds the system waits (after the caller has input the initial digit) for the caller to input a subsequent digit of the dialed digits. The default is 10 seconds. | ||
| timeouts wait-release {value | infinity} | Configure the timeout value for releasing voice ports. This command limits the duration that a voice port stays in the call failure state while the Cisco MC3810 sends a busy tone, reorder tone or out-of-service tone to the port. | ||
| timing digit milliseconds | If the voice-port dial type is DTMF, configure the DTMF digit signal duration. The range of the DTMF digit signal duration is from 50 to 100 milliseconds. The default is 100. | ||
| timing inter-digit milliseconds
| |||
| timing pulse-digit milliseconds
| |||
| timing pulse-inter-digit milliseconds
| |||
| timing wink-duration milliseconds | Configure the timing wink-duration value. This value sets the wink signal duration for a wink-start signal. This value applies only if the signal command is set to "wink-start." The range is from 100 to 400 milliseconds and the default is 200. | ||
| timing wink-wait milliseconds | Configure the timing wink-wait value. This value sets the wink wait duration for a wink-start signal. This value applies only if the signal command is set to "wink-start." The range is from 100 to 5000 milliseconds and the default is 200. | ||
| timing clear-wait milliseconds | Configure the timing clear-wait value. This value sets the amount of time between the inactive seizure signal and the call being cleared. The range is from 100 to 2000 milliseconds and the default is 400. | ||
| timing delay-duration milliseconds | Configure the timing delay-duration value. This value sets the delay signal duration for delay dial signaling. This value applies only if the signal command is set to "delay-dial." The range is from 100 to 5000 milliseonds and the default is 140. | ||
| timing delay-start milliseconds | Configure the timing delay-start value. This value sets the delay interval between the generation of the delay-start signal from incoming detection seizure. This value applies only if the signal command is set to "delay-dial." The range is from 100 to 290 milliseconds and the default is 150. | ||
| timing percentbreak percent | Configure the timing percent-break value. This value sets the percentage of the break period for a dialing pulse. The default is 50 percent. |
After you have configured the voice port, you need to activate the voice port to bring it online. In fact it is a good idea to cycle the port---meaning to shut the port down and then bring it online again.
To activate a voice port, use the following command in voice-port configuration mode:
| Command | Purpose |
|---|---|
no shutdown | Activate the voice port. |
To cycle a voice port, use the following commands in voice-port configuration mode:
| Step | Command | Purpose | ||
|---|---|---|---|---|
| shutdown | Deactivate the voice port. | ||
| voice-port slot-number/subunit-number/port | Identify the voice port you want to activate and enter the voice-port configuration mode. | ||
| no shutdown | Activate the voice port. |
|
|