This chapter describes how to allow asynchronous connections, such as analog modem calls, to enter an access server. It also describes how to set up advanced asynchronous features, such as asynchronous dynamic routing and chat scripts.
For a complete description of the modem support commands in this chapter, refer to the Dial Solutions Command Reference. To locate documentation of other commands that appear in this chapter, use the command reference master index or search online.
The following sections are provided in this chapter:
Modems attach to asynchronous lines, which in turn attach to asynchronous interfaces. Depending on the type of access server you have, these components appear outside or inside the physical chassis. Figure 15 shows the logical relationship between modems, asynchronous lines, asynchronous interfaces, and group asynchronous interfaces. All these components work together to deliver packets as follows:

Deciding which asynchronous features to use, to some degree, depends on your hardware configuration. All Cisco access servers must have their asynchronous interfaces and lines configured for network protocol support. Commands entered in asynchronous interface mode configure protocol-specific parameters for asynchronous interfaces, whereas commands entered in line configuration mode configure the physical and logical aspects for the same port.
Modems inside high-end access servers need localized modem country code. This code is projected from the Cisco IOS software to the onboard modems using the modem country {mica | microcom_hdms} country command. The following are high-end access servers: Cisco AS5800, Cisco AccessPath, Cisco AS5300, and the Cisco AS5200.
Modems externally attached to low-end access servers need to receive initialization strings from the modem autoconfigure discovery command. For troubleshooting tips, see the section "Troubleshoot Externally Attached Modems." The following are low-end access servers: Cisco AS2511-RJ, Cisco AS2509-RJ, Cisco 2509, Cisco 2511, and the Cisco 2512.
Figure 16 shows a Cisco AS2511-RJ access server. Figure 17 shows a Cisco AS5300 access server. Notice that modems are either inside or outside the chassis, depending on the product model.


Asynchronous line configuration commands configure ports for the following options:
To enter line configuration mode, first connect to the console port of the access server and enter privileged EXEC mode. Then enter global configuration mode and finally enter line configuration mode for the asynchronous lines that you want to configure.
The following example is for a Cisco AS5800 access server, which is used as a high-density dial-in solution.
as5800# configure terminal as5800(config)# line 1/2/00 1/9/71 as5800(config-line)# session-timeout 30 as5800(config-line)# exec-timeout 30 0 as5800(config-line)# absolute-timeout 240 as5800(config-line)# autoselect during-login as5800(config-line)# autoselect ppp as5800(config-line)# modem InOut as5800(config-line)# transport preferred none as5800(config-line)# transport input all
The following is an example of one asynchronous line configuration on a Cisco AS2511-RJ access server that is used in an asynchronous backup DDR scenario:
as2511> enable as2511# configure terminal as2511(config)# line 1 as2511(config-line)# modem InOut as2511(config-line)# speed 115200 as2511(config-line)# transport input all as2511(config-line)# flowcontrol hardware
Interfaces enable the Cisco IOS software to use routing functions. Specifically, you configure asynchronous interfaces to support PPP connections. Asynchronous interfaces are configured on access servers for the following functions:
The following is an example of one asynchronous interface configuration on a Cisco AS2511-RJ access server that is used in an asynchronous backup DDR scenario:
as2511(config)# interface async 1 as2511(config-if)# description ASYNC LINE 5293731 TO HIGHWAY as2511(config-if)# encapsulation ppp as2511(config-if)# async default routing as2511(config-if)# async mode dedicated as2511(config-if)# dialer in-band as2511(config-if)# dialer map ip 192.168.10.2 name Router2 broadcast as2511(config-if)# dialer-group 1 as2511(config-if)# ppp authentication chap
To configure multiple asynchronous interfaces at the same time (with the same parameters), you can assign each asynchronous interface to a group and then configure the group. Configurations throughout this guide configure group asynchronous interfaces, rather than configuring each interface separately.
To configure a group asynchronous interface, specify the group async number (an arbitrary number) and the group range (beginning and ending asynchronous interface number). The following example shows the process of creating and configuring a group asynchronous interface for asynchronous interfaces 1 through 96 on a Cisco AS5300 access server, which is loaded with 96 56K MICA modems:
as5300(config)# interface group-async 1 as5300(config-if)#ip unnumbered ethernet 0 as5300(config-if)#encapsulation ppp as5300(config-if)#async mode interactive as5300(config-if)#ppp authentication chap pap as5300(config-if)#peer default ip address pool default as5300(config-if)# group-range 1 96 Building configuration... as5300(config-if)#
The following example is for a Cisco AS5800 access server, which is used as a high-density dial-in solution.
as5800(config)# interface group-async 0 as5800(config-if)#ip unnumbered FastEthernet0/2/0 as5800(config-if)#encapsulation ppp as5800(config-if)#async mode interactive as5800(config-if)#peer default ip address pool default as5800(config-if)#no cdp enable as5800(config-if)#ppp authentication chap as5800(config-if)#hold-queue 10 in as5800(config-if)#group-range 1/2/00 1/9/71 Building configuration... as5800(config-if)#
The TTY line numbering scheme used by your access server or router is specific to your product and its hardware configuration. Refer to the product-specific documentation that came with your product for line numbering scheme information.
For example, the Cisco AS5200 access server has TTY lines that map directly to integrated modems as shown in Table 4. Depending on the shelf, slot, port physical architecture of the access server, the modem and TTY line number schemes will change.
As shown in Table 4, TTY lines 1 through 24 directly connect to modems 1/0 through 1/23, which are installed in the first chassis slot in this example. The TTY lines 25 through 48 directly connect to modems 2/0 through 2/23, which are installed in the second slot.
| TTY Line | Slot/ Modem Number | TTY Line | Slot/ Modem Number |
|---|---|---|---|
1 | 1/0 | 25 | 2/0 |
2 | 1/1 | 26 | 2/1 |
3 | 1/2 | 27 | 2/2 |
4 | 1/3 | 28 | 2/3 |
5 | 1/4 | 29 | 2/4 |
6 | 1/5 | 30 | 2/5 |
7 | 1/6 | 31 | 2/6 |
8 | 1/7 | 32 | 2/7 |
9 | 1/8 | 33 | 2/8 |
10 | 1/9 | 34 | 2/9 |
11 | 1/10 | 35 | 2/10 |
12 | 1/11 | 36 | 2/11 |
13 | 1/12 | 37 | 2/12 |
14 | 1/13 | 38 | 2/13 |
15 | 1/14 | 39 | 2/14 |
16 | 1/15 | 40 | 2/15 |
17 | 1/16 | 41 | 2/16 |
18 | 1/17 | 42 | 2/17 |
19 | 1/18 | 43 | 2/18 |
20 | 1/19 | 44 | 2/19 |
21 | 1/20 | 45 | 2/20 |
22 | 1/21 | 46 | 2/21 |
23 | 1/22 | 47 | 2/22 |
24 | 1/23 | 48 | 2/23 |
Perform the following required tasks to configure modem support for high-end access servers, such as the Cisco AS5800, AS5300, and AS5200:
You must configure the modem lines and set the country code to enable asynchronous connections into your access server.
To configure the modems and line, use the following commands beginning in global configuration mode:
| Step | Command | Purpose | ||
|---|---|---|---|---|
| modem country mica country or modem country microcom_hdms country | Depending on the type of modems loaded in your access server, specify the modem vendor and country code.1 This step is only for high-end access servers, such as the Cisco AS5300. | ||
| line line-number ending-line-number | Enter the number of modem lines to configure. Usually this range is equal to the number of modems in the access server.2 | ||
| transport {input | output} all | Allow all protocols to be used when connecting to the line. For outgoing calls, choose the output option. For incoming calls, use input. | ||
| autoselect {arap | ppp | slip} | Configures the line to automatically startup an ARA, PPP, or SLIP session. | ||
| autoselect during login | Configure the lines to autodetect the connection oriented protocol and display the username:password prompt upon login. | ||
| login authentication dialin | Enable authentication across all asynchronous modem logins. | ||
| modem dialin | Enable incoming calls.3 | ||
| exit | Return to global configuration mode. |
To verify your modem configuration:
NAS# show line
Tty Typ Tx/Rx A Modem Roty AccO AccI Uses Noise Overruns
* 0 CTY - - - - - 0 0 0/0
I 1 TTY 115200/115200 - inout - - - 0 0 0/0
I 2 TTY 115200/115200 - inout - - - 0 0 0/0
3 TTY 115200/115200 - inout - - - 0 0 0/0
4 TTY 115200/115200 - inout - - - 0 0 0/0
5 TTY 115200/115200 - inout - - - 0 0 0/0
6 TTY 115200/115200 - inout - - - 0 0 0/0
7 TTY 115200/115200 - inout - - - 0 0 0/0
8 TTY 115200/115200 - inout - - - 0 0 0/0
9 TTY 115200/115200 - inout - - - 0 0 0/0
10 TTY 115200/115200 - inout - - - 0 0 0/0
.
.
.
90 VTY - - - - - 0 0 0/0
NAS# show line 1
Tty Typ Tx/Rx A Modem Roty AccO AccI Uses Noise Overruns
I 1 TTY 115200/115200 - inout - - - 0 0 0/0
Line 1, Location: "", Type: ""
Length: 24 lines, Width: 80 columns
Baud rate (TX/RX) is 115200/115200, no parity, 1 stopbits, 8 databits
Status: none
Capabilities: Hardware Flowcontrol In, Hardware Flowcontrol Out
Modem Callout, Modem RI is CD, Line usable as async interface
Modem state: Idle
Special Chars: Escape Hold Stop Start Disconnect Activation
^^x none - - none
Timeouts: Idle EXEC Idle Session Modem Answer Session Dispatch
00:10:00 never none not set
Idle Session Disconnect Warning
never
Modem type is unknown.
Session limit is not set.
Time since activation: never
Editing is enabled.
History is enabled, history size is 10.
DNS resolution in show commands is enabled
Full user help is disabled
Allowed transports are pad telnet rlogin. Preferred is telnet.
No output characters are padded
No special data dispatching characters
modem(slot/port)=1/0, csm_state(0x00000100)=CSM_IDLE_STATE, bchan_num=-1
modem_status(0x0000): VDEV_STATUS_UNLOCKED
Modem hardware state: CTS noDSR DTR RTS
If you are having trouble:
NAS# debug modem NAS# debug modem csm NAS# debug isdn q931 NAS# no debug modem NAS# no debug modem csm NAS# no debug isdn q931
NAS# debug modem ? b2b Modem Special B2B csm CSM activity maintenance Modem maintenance activity mica MICA Async driver debugging oob Modem out of band activity tdm B2B Modem/PRI TDM trace Call Trace Upload
Create a group asynchronous interface to project a set of core protocol characteristics to a range of asynchronous interfaces. Configuring the asynchronous interfaces as a group saves you time. Analog modem calls cannot enter the access server without this configuration.
To configure a group asynchronous interface, use the following commands beginning in global configuration mode:
| Step | Command | Purpose | ||
|---|---|---|---|---|
| interface group-async number | Bring up a single group asynchronous interface. | ||
| ip unnumbered loopback number | To conserve IP addresses, configure the asynchronous interfaces as unnumbered, and assign the IP address of the loopback interface to them. 1 | ||
| encapsulation ppp | Enable PPP to run on the asynchronous interfaces in the group. | ||
| async mode interactive | |||
| ppp authentication chap pap list-name | Enable CHAP and PAP authentication on the interface. Replace the list-name variable with a specified authentication list name.2 | ||
| peer default ip address pool poolname | Assign dial-in clients IP addresses from an address pool. 3 | ||
| no cdp enable | Disable the Cisco Discovery Protocol on the interface. | ||
| group-range low-end-of-range high-end-of-range | Specify the range of asynchronous interfaces to include in the group, which is usually equal to the number of modems you have in the access server. | ||
| exit | Return to global configuration mode. |
To verify the group interface configuration and check if one of the asynchronous interfaces are up, use the show interface async command:
NAS# show interface async 1
Async1 is up, line protocol is up
modem(slot/port)=1/0, csm_state(0x00000204)=CSM_IC4_CONNECTED, bchan_num=18
modem_status(0x0002): VDEV_STATUS_ACTIVE_CALL.
Hardware is Async Serial
Interface is unnumbered. Using address of FastEthernet0 (10.1.1.10)
MTU 1500 bytes, BW 115 Kbit, DLY 100000 usec, rely 255/255, load 1/255
Encapsulation PPP, loopback not set, keepalive not set
DTR is pulsed for 5 seconds on reset
LCP Open
Open: IPCP
Last input 00:00:00, output 00:00:00, output hang never
Last clearing of "show interface" counters never
Queueing strategy: fifo
Output queue 0/5, 0 drops; input queue 1/5, 0 drops
5 minute input rate 37000 bits/sec, 87 packets/sec
5 minute output rate 0 bits/sec, 0 packets/sec
31063 packets input, 1459806 bytes, 0 no buffer
Received 0 broadcasts, 0 runts, 0 giants, 0 throttles
0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored, 0 abort
33 packets output, 1998 bytes, 0 underruns
0 output errors, 0 collisions, 0 interface resets
0 output buffer failures, 0 output buffers swapped out
0 carrier transitions
If you are having trouble, enter the following debug commands and then send a call into the access server. Interpret the output and make configuration changes accordingly.
nas-1# undebug all All possible debugging has been turned off nas-1# debug ppp negot PPP protocol negotiation debugging is on nas-1# debug ppp auth PPP authentication debugging is on nas-1# debug modem Modem control/process activation debugging is on nas-1# debug ip peer IP peer address activity debugging is on nas-1# show debug General OS: Modem control/process activation debugging is on Generic IP: IP peer address activity debugging is on PPP: PPP authentication debugging is on PPP protocol negotiation debugging is on nas-1# *Mar 1 21:34:56.958: TTY4: DSR came up *Mar 1 21:34:56.962: tty4: Modem: IDLE->READY *Mar 1 21:34:56.970: TTY4: EXEC creation *Mar 1 21:34:56.978: TTY4: set timer type 10, 30 seconds *Mar 1 21:34:59.722: TTY4: Autoselect(2) sample 7E *Mar 1 21:34:59.726: TTY4: Autoselect(2) sample 7EFF *Mar 1 21:34:59.730: TTY4: Autoselect(2) sample 7EFF7D *Mar 1 21:34:59.730: TTY4: Autoselect(2) sample 7EFF7D23 *Mar 1 21:34:59.734: TTY4 Autoselect cmd: ppp negotiate *Mar 1 21:34:59.746: TTY4: EXEC creation *Mar 1 21:34:59.746: TTY4: create timer type 1, 600 seconds *Mar 1 21:34:59.786: ip_get_pool: As4: using pool default *Mar 1 21:34:59.790: ip_get_pool: As4: returning address = 172.20.1.101 *Mar 1 21:34:59.794: TTY4: destroy timer type 1 (OK) *Mar 1 21:34:59.794: TTY4: destroy timer type 0 *Mar 1 21:35:01.798: %LINK-3-UPDOWN: Interface Async4, changed state to up *Mar 1 21:35:01.834: As4 PPP: Treating connection as a dedicated line *Mar 1 21:35:01.838: As4 PPP: Phase is ESTABLISHING, Active Open *Mar 1 21:35:01.842: As4 LCP: O CONFREQ [Closed] id 1 len 25 *Mar 1 21:35:01.846: As4 LCP: ACCM 0x000A0000 (0x0206000A0000) *Mar 1 21:35:01.850: As4 LCP: AuthProto CHAP (0x0305C22305) *Mar 1 21:35:01.854: As4 LCP: MagicNumber 0x64E923A8 (0x050664E923A8) *Mar 1 21:35:01.854: As4 LCP: PFC (0x0702) *Mar 1 21:35:01.858: As4 LCP: ACFC (0x0802) *Mar 1 21:35:02.718: As4 LCP: I CONFREQ [REQsent] id 3 len 23 *Mar 1 21:35:02.722: As4 LCP: ACCM 0x000A0000 (0x0206000A0000) *Mar 1 21:35:02.726: As4 LCP: MagicNumber 0x00472467 (0x050600472467) *Mar 1 21:35:02.726: As4 LCP: PFC (0x0702) *Mar 1 21:35:02.730: As4 LCP: ACFC (0x0802) *Mar 1 21:35:02.730: As4 LCP: Callback 6 (0x0D0306) *Mar 1 21:35:02.738: As4 LCP: O CONFREJ [REQsent] id 3 len 7 *Mar 1 21:35:02.738: As4 LCP: Callback 6 (0x0D0306) *Mar 1 21:35:02.850: As4 LCP: I CONFREQ [REQsent] id 4 len 20 *Mar 1 21:35:02.854: As4 LCP: ACCM 0x000A0000 (0x0206000A0000) *Mar 1 21:35:02.854: As4 LCP: MagicNumber 0x00472467 (0x050600472467) *Mar 1 21:35:02.858: As4 LCP: PFC (0x0702) *Mar 1 21:35:02.858: As4 LCP: ACFC (0x0802) *Mar 1 21:35:02.862: As4 LCP: O CONFACK [REQsent] id 4 len 20 *Mar 1 21:35:02.866: As4 LCP: ACCM 0x000A0000 (0x0206000A0000) *Mar 1 21:35:02.870: As4 LCP: MagicNumber 0x00472467 (0x050600472467) *Mar 1 21:35:02.870: As4 LCP: PFC (0x0702) *Mar 1 21:35:02.874: As4 LCP: ACFC (0x0802) *Mar 1 21:35:03.842: As4 LCP: TIMEout: State ACKsent *Mar 1 21:35:03.842: As4 LCP: O CONFREQ [ACKsent] id 2 len 25 *Mar 1 21:35:03.846: As4 LCP: ACCM 0x000A0000 (0x0206000A0000) *Mar 1 21:35:03.850: As4 LCP: AuthProto CHAP (0x0305C22305) *Mar 1 21:35:03.854: As4 LCP: MagicNumber 0x64E923A8 (0x050664E923A8) *Mar 1 21:35:03.854: As4 LCP: PFC (0x0702) *Mar 1 21:35:03.858: As4 LCP: ACFC (0x0802) *Mar 1 21:35:03.962: As4 LCP: I CONFACK [ACKsent] id 2 len 25 *Mar 1 21:35:03.966: As4 LCP: ACCM 0x000A0000 (0x0206000A0000) *Mar 1 21:35:03.966: As4 LCP: AuthProto CHAP (0x0305C22305) *Mar 1 21:35:03.970: As4 LCP: MagicNumber 0x64E923A8 (0x050664E923A8) *Mar 1 21:35:03.974: As4 LCP: PFC (0x0702) *Mar 1 21:35:03.974: As4 LCP: ACFC (0x0802) *Mar 1 21:35:03.978: As4 LCP: State is Open *Mar 1 21:35:03.978: As4 PPP: Phase is AUTHENTICATING, by this end *Mar 1 21:35:03.982: As4 CHAP: O CHALLENGE id 1 len 26 from "nas-1" *Mar 1 21:35:04.162: As4 CHAP: I RESPONSE id 1 len 26 from "krist" *Mar 1 21:35:04.170: As4 AUTH: Started process 0 pid 47 *Mar 1 21:35:04.182: As4 CHAP: O SUCCESS id 1 len 4 *Mar 1 21:35:04.186: As4 PPP: Phase is UP *Mar 1 21:35:04.190: As4 IPCP: O CONFREQ [Not negotiated] id 1 len 10 *Mar 1 21:35:04.194: As4 IPCP: Address 172.20.1.2 (0x0306AC140102) *Mar 1 21:35:04.202: As4 CDPCP: O CONFREQ [Closed] id 1 len 4 *Mar 1 21:35:04.282: As4 IPCP: I CONFREQ [REQsent] id 1 len 40 *Mar 1 21:35:04.282: As4 IPCP: CompressType VJ 15 slots CompressSlotID (0x02 06002D0F01) *Mar 1 21:35:04.286: As4 IPCP: Address 0.0.0.0 (0x030600000000) *Mar 1 21:35:04.290: As4 IPCP: PrimaryDNS 0.0.0.0 (0x810600000000) *Mar 1 21:35:04.294: As4 IPCP: PrimaryWINS 0.0.0.0 (0x820600000000) *Mar 1 21:35:04.298: As4 IPCP: SecondaryDNS 0.0.0.0 (0x830600000000) *Mar 1 21:35:04.302: As4 IPCP: SecondaryWINS 0.0.0.0 (0x840600000000) *Mar 1 21:35:04.306: As4 IPCP: O CONFREJ [REQsent] id 1 len 10 *Mar 1 21:35:04.310: As4 IPCP: CompressType VJ 15 slots CompressSlotID (0x02 06002D0F01) *Mar 1 21:35:04.314: As4 CCP: I CONFREQ [Not negotiated] id 1 len 15 *Mar 1 21:35:04.318: As4 CCP: MS-PPC supported bits 0x00000001 (0x1206000000 01) *Mar 1 21:35:04.318: As4 CCP: Stacker history 1 check mode EXTENDED (0x11050 00104) *Mar 1 21:35:04.322: As4 LCP: O PROTREJ [Open] id 3 len 21 protocol CCP *Mar 1 21:35:04.326: As4 LCP: (0x80FD0101000F12060000000111050001) *Mar 1 21:35:04.330: As4 LCP: (0x04) *Mar 1 21:35:04.334: As4 IPCP: I CONFACK [REQsent] id 1 len 10 *Mar 1 21:35:04.338: As4 IPCP: Address 172.20.1.2 (0x0306AC140102) *Mar 1 21:35:04.342: As4 LCP: I PROTREJ [Open] id 5 len 10 protocol CDPCP (0x82 0701010004) *Mar 1 21:35:04.342: As4 CDPCP: State is Closed *Mar 1 21:35:05.186: %LINEPROTO-5-UPDOWN: Line protocol on Interface Async4, ch anged state to up *Mar 1 21:35:05.190: As4 PPP: Unsupported or un-negotiated protocol. Link cdp *Mar 1 21:35:05.190: As4 PPP: Trying to negotiate NCP for Link cdp *Mar 1 21:35:05.194: As4 CDPCP: State is Closed *Mar 1 21:35:05.198: As4 CDPCP: TIMEout: State Closed *Mar 1 21:35:05.202: As4 CDPCP: State is Listen *Mar 1 21:35:06.202: As4 IPCP: TIMEout: State ACKrcvd *Mar 1 21:35:06.206: As4 IPCP: O CONFREQ [ACKrcvd] id 2 len 10 *Mar 1 21:35:06.206: As4 IPCP: Address 172.20.1.2 (0x0306AC140102) *Mar 1 21:35:06.314: As4 IPCP: I CONFACK [REQsent] id 2 len 10 *Mar 1 21:35:06.318: As4 IPCP: Address 172.20.1.2 (0x0306AC140102) *Mar 1 21:35:07.274: As4 IPCP: I CONFREQ [ACKrcvd] id 2 len 34 *Mar 1 21:35:07.278: As4 IPCP: Address 0.0.0.0 (0x030600000000) *Mar 1 21:35:07.282: As4 IPCP: PrimaryDNS 0.0.0.0 (0x810600000000) *Mar 1 21:35:07.286: As4 IPCP: PrimaryWINS 0.0.0.0 (0x820600000000) *Mar 1 21:35:07.286: As4 IPCP: SecondaryDNS 0.0.0.0 (0x830600000000) *Mar 1 21:35:07.290: As4 IPCP: SecondaryWINS 0.0.0.0 (0x840600000000) *Mar 1 21:35:07.294: As4 IPCP: O CONFNAK [ACKrcvd] id 2 len 34 *Mar 1 21:35:07.298: As4 IPCP: Address 172.20.1.101 (0x0306AC140165) *Mar 1 21:35:07.302: As4 IPCP: PrimaryDNS 172.20.5.100 (0x8106AC140564) *Mar 1 21:35:07.306: As4 IPCP: PrimaryWINS 172.20.5.101 (0x8206AC140565) *Mar 1 21:35:07.310: As4 IPCP: SecondaryDNS 172.20.6.100 (0x8306AC140664) *Mar 1 21:35:07.314: As4 IPCP: SecondaryWINS 172.20.6.101 (0x8406AC140665) *Mar 1 21:35:07.426: As4 IPCP: I CONFREQ [ACKrcvd] id 3 len 34 *Mar 1 21:35:07.430: As4 IPCP: Address 172.20.1.101 (0x0306AC140165) *Mar 1 21:35:07.434: As4 IPCP: PrimaryDNS 172.20.5.100 (0x8106AC140564) *Mar 1 21:35:07.438: As4 IPCP: PrimaryWINS 172.20.5.101 (0x8206AC140565) *Mar 1 21:35:07.442: As4 IPCP: SecondaryDNS 172.20.6.100 (0x8306AC140664) *Mar 1 21:35:07.446: As4 IPCP: SecondaryWINS 172.20.6.101 (0x8406AC140665) *Mar 1 21:35:07.446: ip_get_pool: As4: validate address = 172.20.1.101 *Mar 1 21:35:07.450: ip_get_pool: As4: using pool default *Mar 1 21:35:07.450: ip_get_pool: As4: returning address = 172.20.1.101 *Mar 1 21:35:07.454: set_ip_peer_addr: As4: address = 172.20.1.101 (3) is redun dant *Mar 1 21:35:07.458: As4 IPCP: O CONFACK [ACKrcvd] id 3 len 34 *Mar 1 21:35:07.462: As4 IPCP: Address 172.20.1.101 (0x0306AC140165) *Mar 1 21:35:07.466: As4 IPCP: PrimaryDNS 172.20.5.100 (0x8106AC140564) *Mar 1 21:35:07.470: As4 IPCP: PrimaryWINS 172.20.5.101 (0x8206AC140565) *Mar 1 21:35:07.474: As4 IPCP: SecondaryDNS 172.20.6.100 (0x8306AC140664) *Mar 1 21:35:07.474: As4 IPCP: SecondaryWINS 172.20.6.101 (0x8406AC140665) *Mar 1 21:35:07.478: As4 IPCP: State is Open *Mar 1 21:35:07.490: As4 IPCP: Install route to 172.20.1.101 *Mar 1 21:35:25.038: As4 PPP: Unsupported or un-negotiated protocol. Link cdp *Mar 1 21:36:12.614: TTY0: timer type 1 expired *Mar 1 21:36:12.614: TTY0: Exec timer (continued) *Mar 1 21:36:25.038: As4 PPP: Unsupported or un-negotiated protocol. Link cdp *Mar 1 21:37:25.038: As4 PPP: Unsupported or un-negotiated protocol. Link cdp *Mar 1 21:38:25.038: As4 PPP: Unsupported or un-negotiated protocol. Link cdp *Mar 1 21:39:25.038: As4 PPP: Unsupported or un-negotiated protocol. Link cdp *Mar 1 21:40:25.038: As4 PPP: Unsupported or un-negotiated protocol. Link cdp *Mar 1 21:41:25.038: As4 PPP: Unsupported or un-negotiated protocol. Link cdp *Mar 1 21:42:25.038: As4 PPP: Unsupported or un-negotiated protocol. Link cdp *Mar 1 21:43:25.038: As4 PPP: Unsupported or un-negotiated protocol. Link cdp
This section describes the following monitoring and maintenance tasks that you can perform on asynchronous interfaces:
To monitor and maintain asynchronous activity, use the following commands in privileged EXEC mode:
| Command | Purpose |
|---|---|
clear line line-number | Return a line to its idle state. |
Display parameters that have been set for extended BOOTP requests. | |
Display statistics for asynchronous interface activity. | |
show line [line-number] | Display the status of asynchronous line connections. |
To debug asynchronous interfaces, use the following debug command in privileged EXEC mode:
| Command | Purpose |
|---|---|
debug async {framing | state | packets} | Displays errors, changes in interface state, and log input and output. |
To debug PPP links, use the following debug commands in privileged EXEC mode:
| Command | Purpose |
|---|---|
Enable debugging of PPP protocol negotiation process. | |
Display PPP protocol errors. | |
Display PPP packets sent and received. | |
Display errors encountered during remote or local system authentication. |
Some of Cisco's lower-end access servers have cable connections to external modems, such as the Cisco AS2511-RJ shown in Figure 18. Notice that the modems and modem cables are outside the chassis. The asynchronous interfaces and lines are inside the access server.

This section describes how to do the following tasks:
When you configure modems to function with your access server, you must provide initialization strings and other settings on the modem to tell it how to function with the access server.
For modem configuration information about specific access servers that have integrated modems, refer to the section "Check Other Modem Settings" later in this chapter.
Make sure that the line speed on the access server matches the matches transmission rate, as shown in Table 5.
| Modem Transmission Rate | Line Speed on the Access Server |
|---|---|
9600 | 38400 |
14400 | 57600 |
28800 | 115200 |
Use the show run EXEC command. The line configuration fragment appears at the tail end of the output. In this example, lines 7 through 9 are transmitting at 115200 bps. There are 16 28.8 Kbps modems connected to a Cisco AS2511-RJ access server via a modem cable. See Figure 18.
as2511# show run Building configuration... Current configuration: . . . ! line 1 16 login local modem InOut speed 115200 transport input all flowcontrol hardware script callback callback autoselect ppp autoselect during-login !
This section assumes you have already physically attached the modem to the access server. If not, refer to the user guide or installation and configuration guide for your access server for information about attaching modems.
Before you can configure the modem, you must establish communication with it, which requires terminal access to the modem's command environment. The process of manually configuring a modem consists of the following tasks:
You communicate with the modem by establishing a direct Telnet session from the access server's asynchronous line, which is connected to the modem.
To establish a direct Telnet session to an external modem, determine the IP address of your LAN (Ethernet) interface, then enter a Telnet command to port 2000 + n on the access server, where n is the line number to which the modem is connected. For example, to connect to the modem attached to line 1, enter the following command from an EXEC session on the access server:
router# telnet 172.16.1.10 2001 Trying 172.16.1.10, 2001 ... Open
This example enables you to communicate with the modem on line 1 using the AT (attention) command set defined by the modem vendor.
If you are unable to connect to the modem, check the following:
1. Issue the show users EXEC command. It should not indicate the line is in use.
2. Verify that the line is configured for modem inout.
3. Issue the show line EXEC command. The output should contain the following two lines:
Modem state: Idle Modem hardware state: CTS noDSR DTR RTS
4. Check to see if the virtual terminal connections to lines in the access server require passwords.
5. Check to see if the speed between the modem and the access server are the same. They are likely to be different. If they are different, switch off the modem, then switch it back on. This should match the speed of the modem with the speed of the access server.
After you make a direct Telnet connection to the modem, you need to test the connection. Send the modem the AT command to request its attention. It should respond with OK. For example:
at OK
If the modem does not reply to the AT command, check the following:
1. Look at the output of the show line 1 command. If it displays "no CTS" for the modem hardware state, the modem is not connected, powered on, and waiting for data, or the modem might not be configured for hardware flow control.
2. Check your cabling and the modem configuration (echo or result codes might be off). Enter the appropriate AT modem command to view the modem configuration, or enter the command at&f to return to factory defaults. Refer to your modem documentation to learn the appropriate AT command to view your modem configuration.
If you are connected to an external modem, the direct Telnet session must be terminated before the line can accept incoming calls. If you do not terminate the session, it will be indicated in the output of the show users command when it returns a modem state of ready if the line is still in use. If the line is no longer in use, the output of the show line value command will return a state of idle.
Terminating the Telnet session requires first suspending it, then disconnecting it. To suspend a Telnet session, enter the escape sequence Ctrl-Shift-6 x (press Control-Shift-6, let go, then press x). Enter the disconnect EXEC command to terminate the Telnet session.
To suspend and then disconnect a Telnet session, perform the following steps:
Step 1 Enter Ctrl-Shift-6 x to suspend the Telnet session:
- suspend keystroke - router#
Step 2 Enter the where EXEC command to check for open sessions:
router# where Conn Host Address Byte Idle Conn Name * 1 172.16.1.10 172.16.1.10 0 0 172.16.1.10 2 172.16.1.11 172.16.1.11 0 12 modem2
Step 3 After suspending a session with one modem, you can connect to another modem (then suspend it):
router# telnet modem2 Trying modem2 (172.16.1.11, 2002) ... Open - suspend keystroke - router#
Step 4 To disconnect (completely close) a session, issue the disconnect EXEC command:
router# disconnect line 1 Closing connection to 172.16.1.10 [confirm] y router# disconnect line 2 Closing connection to 172.16.1.11 [confirm] y router#
After you have established and tested the connection to the modem, you can proceed with the next section "Automatically Configure an External Modem."
The Cisco IOS software can issue initialization strings automatically for most types of modems externally attached to the access server. A modem initialization string is a series of parameter settings that are sent to your modem to configure it to interact with the access server in a specified way. The Cisco IOS software defines seven initialization strings that have been found to properly initialize most modems so that the modems function properly with Cisco access servers. These initialization strings have the following names:
If you do not know which of these modem strings is appropriate for your modems, issue the modem autoconfigure discovery line configuration command, as shown in the following example:
router# configure terminal router(config)# line 1 16 router(config-line)# modem autoconfigure discovery router(config-line)# Ctrl-Z router# copy system:running-config nvram:startup-config
The Cisco IOS software first tries the first of these strings to see if the modem initializes properly. If not, the Cisco IOS software cycles to the next string and repeats the process until the appropriate string is found. If none of the strings properly initializes the modem, you must manually configure the modem (refer to "Manually Configure an External Modem" later in this chapter).
If you know that your modem can be configured using an initialization string from one of these scripts, you can issue the modem autoconfigure type modem-name command, where modem-name is one of the strings in the preceding list. If you list a specific modem type, initialization proceeds more quickly.
To display the list of modems for which the router has modem string entries, issue the show modemcap command. You can change a modem value that was returned from the show modemcap EXEC command. For example, you might want to add the factory default, &F, entry to the configuration file. To do this, enter the modemcap edit modem-name attribute value line configuration command. Configure one attribute of one modem at a time.
The following example shows how to enter line configuration mode and issue the modem autoconfigure type modem-name command for a US Robotics Sportster modem:
router(config-line)# modem autoconfigure type usr_sportster
For more information about the recommended strings for any type of modem, refer to the section "Sample Modem Strings" in the appendix "Configuring Modem Support and Chat Scripts" in the Dial Solutions Command Reference.
If you cannot configure your modem automatically, you must configure it manually. The following sections describe how to configure your externally attached modem manually:
This section describes how to determine and issue the correct initialization string for your modem and configure your modem with it.
Modem command sets vary widely. Although most modems use the Hayes command set (prefixing commands with AT), Hayes-compatible modems do not use identical AT command sets.
Refer to your modem manufacturer's documentation to learn how to examine the current and stored configuration of the modem you are using. Generally, you enter AT commands such as &v, i4, or *o to view, inspect, or observe the settings.
A sample modem initialization string for a US Robotics Courier modem is as follows:
&b1&h1&r2&c1&d3&m4&k1s0=1
Modem initialization strings enable the following functions:
![]() | TimeSaver Initialization strings for other modems are listed in the appendix "Configuring Modem Strings and Chat Scripts" in the Dial Solutions Command Reference. |
The port speed must not change when a session is negotiated with a remote modem. If the speed of the port on the access server is changed, you must establish a direct Telnet session to the modem and send an AT command so that the modem can learn the new speed.
Modems differ in the method they use to lock the EIA/TIA-232 (serial) port speed. In the modem documentation, vendors use terms such as, port-rate adjust, speed conversion, or buffered mode. Enabling error correction often puts the modem in the buffered mode. Refer to your modem documentation to see how your modem locks speed (check the settings &b, \j, &q, \n, or s-register settings).
This section defines other settings that might be needed or desirable depending on your modem.
Refer to this section if you could not or chose not to initialize your modems automatically, as described in the "Automatically Configure an External Modem" section earlier in this chapter.
After the modem initialization string has been determined, perform the following steps to configure the modem. The steps below configure a U.S. Robotics Courier modem on line 1 (decimal number 2000 + line number 1 = 2001).
Step 1 Map a host name to a decimal port. The port number is 200x, plus the number of the TTY line. The following example maps port 2001 to the IP address of the Ethernet0 interface on the access server (172.16.1.10):
router(config)# ip host modem1 2001 172.16.1.10 router(config)# exit router#
Step 2 Establish a direct Telnet session to the modem:
router# telnet modem1 Trying modem1 (172.16.1.10, 2001)... Open
Step 3 Return the modem to its factory defaults (this step is optional):
at&f OK
Step 4 Configure the modem with an initialization string. The following example string is for a U.S. Robotics Courier modem:
at&b1&h1&r2&c1&d3&m4&k1s0=1 OK
Step 5 Store the modem settings in NVRAM on the modem:
at&w OK
Step 6 Suspend and disconnect your Telnet session:
- suspend keystroke - router# disconnect Closing connection to modem1 [confirm] y router#
![]() | TimeSaver The script-reset line configuration command can automate the configuration of your modems. See the "Technical Tips" section on CCO for more information. |
The access server and modem are now correctly configured for dial-in access. Before configuring any additional protocols for the line (such as SLIP, PPP, or ARA), test the dial-in connection.
The following is an example of a successful connection from a PC using a U.S. Robotics Courier modem to dial in to a Cisco 2500 series access server:
at&f&c1&d3&h1&r2&b1&m4&k1&w OK atdt9,5551234 CONNECT 14400/ARQ/V32/LAPM/V42BIS User Access Verification Username: janedoe Password: router>
The following modem line characteristics and modem features are discussed in the following sections:
This section provides information to help you understand modem signaling, flow control, and line states.
The EIA/TIA-232 output signals are Transmit Data (TXDATA), Data Terminal Ready (DTR), and Ready To Send (RTS, 2500 only). The input signals are Receive Data (RXDATA), Clear to Send (CTS), and RING. The sixth signal is ground. Depending on the type of modem control your modem uses, these names may or may not correspond to the standard EIA/TIA-232 signals.
Dial-up modems that operate over normal telephone lines at speeds of 28800 bps use hardware flow control to stop the data from reaching the host by toggling an EIA/TIA-232 signal when their limit is reached.
In addition to hardware flow control, modems require special software configuring. For example, they must be configured to create an EXEC session when a user dials in and to hang up when the user exits the EXEC. These modems also must be configured to close any existing network connections if the telephone line hangs up in the middle of a session.
The Cisco IOS software supports hardware flow control on its CTS input signal, which is also used by the normal modem handshake.
Signal and line state diagrams accompany some of the tasks in the following sections to illustrate how the modem control works. The diagrams show two processes:
In the diagrams, the current signal state and the signal the line is watching are listed inside each box. The state of the line (as displayed by the show line EXEC command) is listed next to the box. Events that change that state appear in italics along the event path, and actions that the software performs are described within the ovals.
Figure 19 illustrates line states when no modem control is set. The DTR output is always high, and CTS and RING are completely ignored. The Cisco IOS software starts an EXEC session when the user types the activation character. Incoming TCP connections occur instantly if the line is not in use and can be closed only by the remote host.

With the dial-up capability, you can set a modem to dial the phone number of a remote router automatically. This feature offers cost savings because phone line connections are made only when they are needed---you only pay for using the phone line when there is data to be received or sent. To configure a line for automatic dialing, use the following command in line configuration mode:
| Command | Purpose |
|---|---|
Configure a line to initiate automatic dialing. |
Using the modem dtr-active command causes a line to raise DTR signal only when there is an outgoing connection (such as reverse Telnet, NASI, or DDR), rather than leave DTR raised all the time. When raised, DTR potentially tells the modem that the router is ready to accept a call.
You can configure a line to answer a modem automatically. You also can configure the modem to answer the telephone on its own (as long as DTR is high), drop connections when DTR is low, and use its Carrier Detect (CD) signal to accurately reflect the presence of carrier. (Configuring the modem is a modem-dependent process.) Wire the modem's CD signal (generally pin-8) to the router's RING input (pin-22), and use the following command in line configuration mode:
| Command | Purpose |
|---|---|
Configure a line to automatically answer a modem. |
You can turn on the modem's hardware flow control independently to respond to the status of the router's CTS input. Wire CTS to whatever signal the modem uses for hardware flow control. If the modem expects to control hardware flow in both directions, you might also need to wire the modem's flow control input to some other signal that the router always has high (such as the DTR signal).
Figure 20 illustrates the modem dialin process with a high-speed dial-up modem. When the Cisco IOS software detects a signal on the RING input of an idle line, it starts an EXEC or autobaud process on that line. If the RING signal disappears on an active line, the Cisco IOS software closes any open network connections and terminates the EXEC facility. If the user exits the EXEC or the software terminates because of no user input, the line makes the modem hang up by lowering the DTR signal for five seconds. After five seconds, the modem is ready to accept another call.

You can configure a line for both incoming and outgoing calls by using the following command in line configuration mode:
| Command | Purpose |
|---|---|
Configure a line for both incoming and outgoing calls. |
Figure 21 illustrates the modem inout command. If the line is activated by raising the data set ready (DSR) signal, it functions exactly as a line configured with the modem dialin line configuration command described in the "Automatically Answer a Modem" section earlier in this chapter. If the line is activated by an incoming TCP connection, the line functions similarly to lines not used with modems.
You can change the interval that the Cisco IOS software waits for the CTS signal after raising the DTR signal in response to the DSR (the default is 15 seconds). To do so, use the following command in line configuration mode. The timeout applies to the modem callin command only.
| Command | Purpose |
|---|---|
Configure modem line timing. |
You can configure a line to close connections from a user's terminal when the terminal is turned off and prevent inbound connections to devices that are out of service. To do so, use the following command in line configuration mode:
| Command | Purpose |
|---|---|
Configure a line to close connections. |
Figure 22 illustrates the modem cts-required command operating in the context of a continuous CTS signal. This form of modem control requires that the CTS signal be high for the entire session. If CTS is not high, the user's input is ignored and incoming connections are refused (or sent to the next line in a rotary group).

You can configure automatic line disconnect by using the following command in line configuration mode:
| Command | Purpose |
|---|---|
Configure automatic line disconnect. |
The autohangup command causes the EXEC facility to issue the exit command when the last connection closes. This feature is useful for UNIX-to-UNIX copy program (UUCP) applications because UUCP scripts cannot issue a command to hang up the telephone. This feature is not often used.
The Cisco IOS software supports dial-in modems that use DTR to control the off-hook status of the telephone line. This feature is supported primarily on old-style modems, especially those in Europe. To configure the line to support this feature, use the following command in line configuration mode:
| Command | Purpose |
|---|---|
Configure a line for a dial-in modem. |
Figure 23 illustrates the modem callin command. When a modem dialing line is idle, it has its DTR signal at a low state and waits for a transition to occur on the DSR (RING) input. This transition causes the line to raise the DTR signal and start watching the CTS signal from the modem. After the modem raises CTS, the Cisco IOS software creates an EXEC session on the line. If the timeout interval (set with the modem answer-timeout command) passes before the modem raises the CTS signal, the line lowers the DTR signal and returns to the idle state.

Although you can use the modem callin line configuration command with newer modems, the modem dialin line configuration command described in this section is more appropriate. The modem dialin command frees up CTS input for hardware flow control. Modern modems do not require the assertion of DTR to answer a phone line (that is, to take the line off-hook).
In addition to initiating connections, the Cisco IOS software can receive incoming connections. This capability allows you to attach serial and parallel printers, modems, and other shared peripherals to the router or access server and drive them remotely from other modem-connected systems. The Cisco IOS software supports reverse TCP, XRemote, and LAT connections.
The specific TCP port or socket, to which you attach the device determines the type of service that the Cisco IOS software provides on a line. When you attach the serial lines of a computer system or a data terminal switch to the serial lines of the access server, the access server can act as a network front-end device for a host that does not support the TCP/IP protocols. This arrangement is sometimes called front-ending, or reverse connection mode.
The Cisco IOS software supports ports connected to computers that are connected to modems. You can configure the Cisco IOS software to function somewhat like a modem by using the following command in line configuration mode. This command also prevents incoming calls.
| Command | Purpose |
|---|---|
Configure a line for reverse connections and prevent incoming calls. |
Figure 24 illustrates the modem callout process. When the Cisco IOS software receives an incoming connection, it raises the DTR signal and waits to see if the CTS signal is raised to indicate that the host has noticed the router's DTR signal. If the host does not respond within the interval set by the modem answer-timeout line configuration command, the software lowers the DTR signal and drops the connection.

To configure Cisco IOS software to respond to BOOTP requests from client machines, use the following command in global configuration mode:
| Command | Purpose |
|---|---|
Specify the router network information that is sent in response to BOOTP requests. |
To specify the mode of a low-speed serial interface as either synchronous or asynchronous, use the following command in interface configuration mode:
| Command | Purpose |
|---|---|
physical-layer {sync | async} | Specify the mode of a low-speed interface as either synchronous or asynchronous. |
This command applies only to low-speed serial interfaces available on Cisco 2520 through Cisco 2523 routers.
In synchronous mode, low-speed serial interfaces support all interface configuration commands available for high-speed serial interfaces, except the following two commands:
When placed in asynchronous mode, low-speed serial interfaces support all commands available for standard asynchronous interfaces. The default is synchronous mode.
Note that when you enter this command, it does not appear in the output of more system:running-config and more nvram:startup-config command, because the command is a physical-layer command.
When asynchronous routing is enabled, you might find it necessary to conserve network addresses by configuring the asynchronous interfaces as unnumbered. An unnumbered interface does not have an address. Network resources are therefore conserved because fewer network numbers are used and routing tables are smaller.
To configure an unnumbered interface, use the following command in interface configuration mode:
| Command | Purpose |
|---|---|
Conserve IP addresses by configuring the asynchronous interfaces as unnumbered, and assign the IP address of the interface type that you want to leverage. |
Whenever the unnumbered interface generates a packet (for example, a routing update), it uses the address of the specified interface as the source address of the IP packet. It also uses the address of the specified interface to determine which routing processes are sending updates over the unnumbered interface.
You can use the IP unnumbered feature even if the system on the other end of the asynchronous link does not support it. The IP unnumbered feature is transparent to the other end of the link because each system bases its routing activities on information in the routing updates it receives and on its own interface address.
You can control whether addressing is dynamic (the user specifies the address at the EXEC level when making the connection), or whether default addressing is used (the address is forced by the system). If you specify dynamic addressing, the router must be in interactive mode and the user will enter the address at the EXEC level.
It is common to configure an asynchronous interface to have a default address and to allow dynamic addressing. With this configuration, the choice between the default address or a dynamic addressing is made by the users when they enter the slip or ppp EXEC command. If the user enters an address, it is used, and if the user enters the default keyword, the default address is used.
This section describes the following tasks:
Use the following command in interface configuration mode to assign a permanent default asynchronous address:
| Command | Purpose |
|---|---|
Assign a default IP address to an asynchronous interface. |
Use the no form of this command to disable the default address. If the server has been configured to authenticate asynchronous connections, you are prompted for a password after entering the slip default or ppp default EXEC command before the line is placed into asynchronous mode.
The assigned default address is implemented when the user enters the slip default or ppp default EXEC command. The transaction is validated by the Terminal Access Controller Access System (TACACS) server, when enabled, and the line is put into network mode using the address that is in the configuration file.
Configuring a default address is useful when the user is not required to know the IP address to gain access to a system (for example, users of a server that is available to many students on a campus). Instead of requiring each user to know an IP address, they only need to enter the slip default or ppp default EXEC command and let the server select the address to use. See the chapter "Making Connections to Network Devices" in this book for more information about the slip and ppp EXEC commands.
When a line is configured for dynamic assignment of asynchronous addresses, the user enters the slip or ppp EXEC command and is prompted for an address or logical host name. The address is validated by TACACS, when enabled, and the line is assigned the given address and put into asynchronous mode. Assigning asynchronous addresses dynamically is also useful when you want to assign set addresses to users. For example, an application on a personal computer that automatically dials in using SLIP and polls for electronic mail messages can be set up to dial in periodically and enter the required IP address and password.
To assign asynchronous addresses dynamically, use the following command in interface configuration mode:
| Command | Purpose |
|---|---|
Allow the IP address to be assigned when the protocol is initiated. |
The dynamic addressing features of the internetwork allow packets to get to their destination and back regardless of the access server, router, or network they are sent from. For example, if a host such as a laptop computer moves from place to place it can keep the same address no matter where it is dialing in from.
Logical host names are first converted to uppercase and then sent to the TACACS server for authentication.
You can configure one or more asynchronous interfaces on your access server (and one on a router) to be in dedicated network interface mode. In dedicated mode, an interface is automatically configured for SLIP or PPP connections. There is no user prompt or EXEC level, and no end-user commands are required to initiate remote-node connections. If you want a line to be used only for SLIP or PPP connections, configure the line for dedicated mode.
In interactive mode, a line can be used to make any type of connection, depending on the EXEC command entered by the user. For example, depending on its configuration, the line could be used for Telnet or XRemote connections, or SLIP or PPP encapsulation. The user is prompted for an EXEC command before a connection is initiated.
You can configure an asynchronous interface to be in dedicated network mode. When the interface is configured for dedicated mode, the end user cannot change the encapsulation method, address, or other parameters.
To configure an interface for dedicated network mode or return it back to interactive mode, use one of the following commands in interface configuration mode.
| Command | Purpose |
|---|---|
Place the line into dedicated asynchronous network mode. | |
Return the line to interactive mode. |
To route IP packets on an asynchronous interface, use one of the following commands in interface configuration mode:
| Command | Purpose |
|---|---|
Configure an asynchronous interface for dynamic routing. Use this command to manually bring up PPP from an EXEC session. | |
Automatically configure an asynchronous interface for routing. Use this command to enable two routers to communicate over an async dial backup link. |
This async dynamic routing command routes IP packets on an asynchronous interface, which permits you to enable the IGRP, RIP, and OSPF routing protocols for use when the user makes a connection using the ppp or slip EXEC commands. The user must, however, specify the /routing keyword at the SLIP or PPP command line.
For asynchronous interfaces in interactive mode, the async default routing command causes the ppp and slip EXEC commands to be interpreted as though the /route switch had been included in the command. For asynchronous interfaces in dedicated mode, the async dynamic routing command enables routing protocols to be used on the line. Without the async default routing command, there is no way to enable the use of routing protocols automatically on a dedicated asynchronous interface.
By default, the Cisco IOS software starts an EXEC process on all lines. However, you can control EXEC processes, as follows:
The EXEC command interpreter waits for a specified amount of time to receive user input. If no input is detected, the EXEC facility resumes the current connection. If no connections exist, it returns the terminal to the idle state and disconnects the incoming connection. To control the EXEC process, use the following commands in line configuration mode:
| Step | Command | Purpose | ||
|---|---|---|---|---|
| Turn on EXEC processes. | |||
| exec-timeout minutes [seconds] | Set the idle terminal timeout interval. |
The AUX port sends a DTR signal only when a Telnet connection is established. The auxiliary port does not use Ready to Send/Clear to Send (RTS/CTS) handshaking for flow control. To understand the differences between standard asynchronous interfaces and AUX ports configured as an asynchronous interface, refer to Table 6. To enable the auxiliary port, use the following command in global configuration mode:
| Command | Purpose |
|---|---|
line aux line-number | Enable the auxiliary serial DTE port. |
You cannot use the auxiliary (AUX) port as a second console port. To use the AUX port as a console port, you must order a special cable from your technical support personnel.
On an access server, you can configure any of the available asynchronous interfaces (1 through 8, 16, or 48). The auxiliary port (labeled AUX on the back of the product) can also be configured as an asynchronous serial interface, although performance on the AUX port is much slower than on standard asynchronous interfaces and does not support some features. Table 6 illustrates why asynchronous interfaces permit substantially better performance than AUX ports configured as asynchronous interfaces.
| Feature | Asynchronous Interface | Auxiliary Port |
|---|---|---|
Maximum speed | 115200 kbps | 38400 kbps |
Supports DMA buffering1 | Yes | No |
PPP framing on chip2 | Yes | No |
IP fast switching3 | Yes | No |
On routers without built-in asynchronous interfaces, only the AUX port can be configured as an asynchronous serial interface. To configure the AUX port as an asynchronous interface, you must also configure it as an auxiliary line with the line aux 1 command. Access servers do not have this restriction. Use the line command with the appropriate line configuration commands for modem control, such as speed.
Only IP packets can be sent across lines configured for SLIP. PPP supports transmission of IP, IPX, and AppleTalk packets on an asynchronous serial interface.
Autoselect is used by the access server to sense the protocol being received on an incoming line and launch the appropriate protocol. Autoselect can be used for AppleTalk Remote Access (ARA), Point-to-Point Protocol (PPP), or Serial Line Internet Protocol (SLIP).
When using Autoselect, "login" authentication is by-passed, so if security is required it must be performed at the protocol level (i.e. ARAP or PPP authentication). SLIP does not offer protocol layer authentication.
To configure the Cisco IOS software to allow and ARA, PPP, SLIP session to start automatically, use the following command in line configuration mode:
| Command | Purpose |
|---|---|
autoselect {arap | ppp | slip | during login} | Configure a line to automatically start an ARA, PPP, or SLIP session. |
The autoselect command enables the Cisco IOS software to start a process automatically when a start character is received.
The autoselect command bypasses the login prompt and enables the specified session to begin automatically. However, by entering the autoselect command with the during login keyword, the username or password prompt appears without needing to press the Return key, thus "login" users will get a decent prompt instead of needing to press the Return key. While the username or password prompt is displayed, you can choose either to answer these prompts or to send packets from an autoselected protocol.
Normally a router avoids line and modem noise by clearing the initial data received within the first one or two seconds. However, when the autoselect PPP feature is configured, the router flushes characters initially received and then waits for more traffic. This flush causes time out problems with applications that send only one carriage return. To ensure that the input data sent by a modem or other asynchronous device is not lost after line activation, enter the flush-at-activation line configuration command.
The following trace appears when the debug modem command and debug ppp negotiation command are enabled. As PPP calls pass through the access server, you should see this output.
When using autoselect, "login" authentication is by-passed. If security is required it must be performed at the protocol level (i.e. ARAP or PPP authentication). SLIP does not offer protocol layer authentication.
22:21:02: TTY1: DSR came up 22:21:02: tty1: Modem: IDLE->READY 22:21:02: TTY1: Autoselect started 22:21:05: TTY1: Autoselect sample 7E 22:21:05: TTY1: Autoselect sample 7EFF 22:21:05: TTY1: Autoselect sample 7EFF7D 22:21:05: TTY1 Autoselect cmd: ppp default 22:21:05: TTY1: EXEC creation %LINK-3-UPDOWN: Interface Async1, changed state to up 22:21:07: ppp: sending CONFREQ, type = 2 (CI_ASYNCMAP), value = A0000 22:21:07: ppp: sending CONFREQ, type = 5 (CI_MAGICNUMBER), value = 23BE13AA 22:21:08: PPP Async1: state = REQSENT fsm_rconfack(0xC021): rcvd id 0x11 22:21:08: ppp: config ACK received, type = 2 (CI_ASYNCMAP), value = A0000 22:21:08: ppp: config ACK received, type = 5 (CI_MAGICNUMBER), value = 23BE13AA 22:21:08: ppp: config ACK received, type = 7 (CI_PCOMPRESSION) 22:21:08: ppp: config ACK received, type = 8 (CI_ACCOMPRESSION) 22:21:08: PPP Async1: received config for type = 0x2 (ASYNCMAP) value = 0x0 acked 22:21:08: PPP Async1: received config for type = 0x5 (MAGICNUMBER) value = 0x2A acked 22:21:08: PPP Async1: received config for type = 0x7 (PCOMPRESSION) acked 22:21:08: PPP Async1: received config for type = 0x8 (ACCOMPRESSION) acked 22:21:08: ipcp: sending CONFREQ, type = 3 (CI_ADDRESS), Address = 172.16.1.1 22:21:08: ppp Async1: ipcp_reqci: rcvd COMPRESSTYPE (rejected) (REJ) 22:21:08: ppp Async1: Negotiate IP address: her address 0.0.0.0 (NAK with address 172.16.1.100) (NAK) 22:21:08: ppp: ipcp_reqci: returning CONFREJ. 22:21:08: PPP Async1: state = REQSENT fsm_rconfack(0x8021): rcvd id 0x9 22:21:08: ipcp: config ACK received, type = 3 (CI_ADDRESS), Address = 172.16.1.1 22:21:08: ppp Async1: Negotiate IP address: her address 0.0.0.0 (NAK with address 172.16.1.100) (NAK) 22:21:08: ppp: ipcp_reqci: returning CONFNAK. 22:21:09: ppp Async1: Negotiate IP address: her address 172.16.1.100 (ACK) 22:21:09: ppp: ipcp_reqci: returning CONFACK. %LINEPROTO-5-UPDOWN: Line protocol on Interface Async1, changed state to up
The following trace appears when the debug modem command and debug arap internal command are enabled. As ARA version 2.0 calls pass through the access server, this output is displayed.
20:45:11: TTY3: DSR came up 20:45:11: tty3: Modem: IDLE->READY 20:45:11: TTY3: EXEC creation 20:45:11: TTY3: Autoselect(2) sample 1 20:45:11: TTY3: Autoselect(2) sample 11B 20:45:12: TTY3: Autoselect(2) sample 11B02 20:45:18: ARAP: ---------- SRVRVERSION ---------- 20:45:19: ARAP: ---------- ACKing 0 ---------- 20:45:19: ARAP: ---------- AUTH_CHALLENGE ---------- 20:45:21: ARAP: ---------- ACKing 1 ---------- 20:45:21: ARAP: ---------- AUTH_RESPONSE ---------- 20:45:21: ARAP: ---------- STARTINFOFROMSERVER ---------- 20:45:22: ARAP: ---------- ACKing 2 ---------- 22:45:22: ARAP: ---------- ZONELISTINFO ---------- 22:45:22: ARAP: ---------- ZONELISTINFO ---------- 22:45:22: ARAP: ---------- ZONELISTINFO ----------
The following trace is for ARA version 1.0 calls.
22:31:45: TTY1: DSR came up 22:31:45: tty1: Modem: IDLE->READY 22:31:45: TTY1: Autoselect started 22:31:46: TTY1: Autoselect sample 16 22:31:46: TTY1: Autoselect sample 1610 22:31:46: TTY1: Autoselect sample 161002 22:31:47: ARAP: ---------- SRVRVERSION ---------- 22:31:47: ARAP: ---------- ACKing 0 ---------- 22:31:47: ARAP: ---------- AUTH_CHALLENGE ---------- 22:31:47: ARAP: ---------- ACKing 1 ---------- 22:31:47: ARAP: ---------- AUTH_RESPONSE ---------- 22:31:47: ARAP: ---------- STARTINFOFROMSERVER ---------- 22:31:48: ARAP: ---------- ACKing 2 ---------- 22:31:48: ARAP: ---------- ZONELISTINFO ---------- 22:31:48: ARAP: ---------- ZONELISTINFO ---------- 22:31:49: ARAP: ---------- ZONELISTINFO ----------
You can set up a command to execute automatically when the router connects to another host. The Cisco IOS software can execute any appropriate EXEC command and any switch or host name that occurs with the EXEC command. To define a command, use the following command in line configuration mode:
| Command | Purpose |
|---|---|
autocommand command | Define a command to be automatically executed. |
Connections can be made to the next free line in a group of lines, also called a rotary group or hunt group. A line can be in only one rotary group; a rotary group can consist of a single line or several contiguous lines. The console line (line 0) cannot be in a rotary group.
To configure a rotary group, use the following command in line configuration mode:
| Command | Purpose |
|---|---|
rotary group | Add a line to the specified rotary group. |
Connections to an individual line are most useful when a dial-out modem, parallel printer, or serial printer is attached to that line. To connect to an individual line, the remote host or terminal must specify a particular TCP port on the router.
If reverse XRemote is required, that port is 9000 (decimal) plus the decimal value of the line number.
If a raw TCP stream is required, the port is 4000 (decimal) plus the decimal line number. The raw TCP stream is usually the required mode for sending data to a printer.
If Telnet protocols are required, that port is 2000 (decimal) plus the decimal value of the line number. The Telnet protocol might require that Return characters be translated into Return and line-feed character pairs. You can turn off this translation by specifying the Telnet binary mode option. To specify this option, connect to port 6000 (decimal) plus the decimal line number.
line 10 flowcontrol software no exec
A host that wants to send data to the printer would connect to the router on TCP port 4008, send the data, and then close the connection. (Remember that line number 10 octal equals 8 decimal.)
Asynchronous lines have relatively low bandwidth and can easily be overloaded, resulting in slow traffic across these lines.
To optimize available bandwidth, perform any of the following tasks:
One way to optimize available bandwidth is by using TCP header compression. Van Jacobson TCP header compression (defined by RFC 1144) can increase bandwidth availability between two and five times when compared to lines not using header compression. Theoretically, it can improve bandwidth availability by a ratio of seven to one.
To configure header compression, use the following command in interface configuration mode:
| Command | Purpose |
|---|---|
Configure Van Jacobson TCP header compression on the asynchronous link. |
On SLIP interfaces, you can force header compression at the EXEC prompt on a line on which header compression has been set to passive. This allows more efficient use of the available bandwidth and does not require entering privileged configuration mode.
To implement header compression, use the following command in interface configuration mode:
| Command | Purpose |
|---|---|
ip tcp header-compression passive | Allow status of header compression to be assigned at the user level. |
For PPP interfaces, the passive option functions the same as the on option.
Refer to the following sections to create and use chat scripts:
See the section "Create Chat Scripts" in the chapter "Preparing for Asynchronous DDR" for additional information about creating and using chat scripts.
Chat scripts are strings of text used to send commands for modem dialing, logging onto remote systems, and initializing asynchronous devices connected to an asynchronous line. On a router, chat scripts can be configured on the auxiliary port only. A chat script must be configured to dial out on asynchronous lines. You also can configure chat scripts so that they are executed automatically for other specific events on a line, or so that they are executed manually. Each chat script is defined for a different event. These events can include the following:
The following tasks are required to use a chat script:
To define a chat script, use the following command in global configuration mode:
| Command | Purpose |
|---|---|
chat-script script-name expect send... | Create a script that will place a call on a modem, log on to a remote system, or initialize an asynchronous device on a line. |
A limited list of keywords are supported, along with expect/send pairs. Send strings can have special escape modifiers.
Cisco recommends that one chat script (a "modem" chat script) be written for placing a call and another chat script (a "system" or "login" chat script) be written to log onto remote systems, where required.
Chat scripts are not supported on lines where modem control is set for inbound activity that only uses the modem dialin command.
When you create a script name, include the modem vendor, type, and modulation, separated by hyphens. For example, if you have a Telebit t3000 modem that uses V.32bis modulation, your script name would be telebit-t3000-v32bis.
A suggested naming convention for chat scripts used to dial is as follows:
vendor-type-modulationIn other words, the syntax of the chat-script command becomes the following:
chat-script vendor-type-modulation expect send...For example, if you have a Telebit t3000 modem that uses V.32bis modulation, you would name your chat script as follows:
telebit-t3000-v32bisThe chat-script command could become the following:
router(config)# chat-script telebit-t3000-v32bis ABORT ERROR ABORT BUSY ABORT
"NO ANSWER" "" "ATH" OK "ATDT\T" TIMEOUT 30 CONNECT
Adhering to this naming convention allows you to specify a range of chat scripts using partial chat script names with regular expressions. This is particularly useful for dialer rotary groups.
Chat scripts can be activated by any of five events, each corresponding to a different version of the script line configuration command. To start a chat script manually at any point, refer to the following section, "Start a Chat Script Manually on an Asynchronous Line."
To define a chat script to start automatically when a specific event occurs, use the following commands in line configuration mode:
| Step | Command | Purpose | ||
|---|---|---|---|---|
| script activation regexp1 | Start a chat script on a line when the line is activated (every time a command EXEC is started on the line). | ||
| script connection regexp | Start a chat script on a line when a network connection is made to the line. | ||
| script dialer regexp | Specify a modem script for DDR on a line. | ||
| script reset regexp | Start a chat script on a line whenever the line is reset. | ||
| script startup regexp | Start a chat script on a line whenever the system is started up. |
| 1The argument regexp is a regular expression that is matched to a script name that has already been defined using the chat-script command. |
You can start a chat script manually on any line that is currently not active by using the following command in privileged EXEC mode:
| Command | Purpose |
|---|---|
start-chat regexp [line-number [dialer-string]] | Start a chat script manually on any asynchronous line. |
If you do not specify the line number, the script runs on the current line. If the line specified is already in use, you cannot start the chat script. A message appears indicating that the line is already in use.
This section illustrates different communication requirements for the following asynchronous scenarios:
The following example assumes that users are restricted to certain servers designated as asynchronous servers, but that normal terminal users can access anything on the local network.
! access list for normal connections access-list 1 permit 131.108.0.0 0.0.255.255 ! access-list 2 permit 131.108.42.55 access-list 2 permit 131.108.111.1 access-list 2 permit 131.108.55.99 ! line 1 speed 19200 flow hardware modem inout interface async 1 async mode interactive async dynamic address ip access-group 1 out ip access-group 2 in
The following sections provide examples of the use of DHCP and local pooling mechanisms.
ip address-pool dhcp-proxy-client
The following global configuration example illustrates how to specify which DHCP servers are used on your network. You can specify up to four servers using IP addresses or names. If you do not specify servers, the default is to use the IP limited broadcast address of 255.255.255.255 for transactions with any and all discovered DHCP servers.
ip dhcp-server jones smith wesson
The following interface configuration example illustrates how to disable DHCP proxy-client functionality on asynchronous interface 1:
async interface interface 1 no peer default ip address
! this command tells the access server to use a local pool ip address-pool local ! this command defines the ip address pool.
! The address pool is named group1 and comprised of addresses ! 10.1.2.1through 10.1.2.5 inclusive ip local-pool group1 10.1.2.1 10.1.2.5
This example shows how to configure the access server so that it will use the default address pool on all interfaces except interface 7, on which it will use an address pool called lass:
ip address-pool local ip local-pool lass 172.30.0.1 async interface interface 7 peer default ip address lass
The following example shows how to create an asynchronous group interface 0 with group interface members 2 through 7, starting in global configuration mode:
interface group-async 0
group-range 2 7
The following example shows how you need to configure asynchronous interfaces 1, 2, and 3 separately if you do not have a group interface configured:
interface Async1 ip unnumbered Ethernet0 encapsulation ppp async default ip address 172.30.1.1 async mode interactive async dynamic routing ! interface Async2 ip unnumbered Ethernet0 encapsulation ppp async default ip address 172.30.1.2 async mode interactive async dynamic routing ! interface Async3 ip unnumbered Ethernet0 ! encapsulation ppp async default ip address 172.30.1.3 async mode interactive async dynamic routing
The following example configures the same interfaces, but from a single group asynchronous interface:
! interface Group-Async 0 ip unnumbered Ethernet0 encapsulation ppp async mode interactive async dynamic routing group-range 1 3 member 1 async default ip address 172.30.1.1 member 2 async default ip address 172.30.1.2 member 3 async default ip address 172.30.1.3
The following example assigns an IP address to an asynchronous interface and places the line in dedicated network mode. Setting the stop bit to 1 is a performance enhancement.
line 20 location Department PC Lab stopbits 1 speed 19200 ! interface async 20 async default ip address 182.32.7.51 async mode dedicated
The following example configures IP-SLIP on asynchronous interface 6. The IP address for the interface is assigned to Ethernet 0, interactive mode has been enabled, and the IP address of the client PC running SLIP has been specified.
IP and the appropriate IP routing protocols have already been enabled on the access server or router.
interface async 6 ip unnumbered ethernet 0 encapsulation slip async mode interactive async default ip address 172.18.1.128
The following example configures asynchronous interface 4 on the router so that users can access AppleTalk zones by dialing into the router via PPP to this interface. Users accessing the network can run AppleTalk and IP natively on a remote Macintosh, access any available AppleTalk zones from Chooser, use networked peripherals, and share files with other Macintosh users. Routing is not supported on the asynchronous interface 6.
interface async 6 encapsulation ppp appletalk virtual-net 12345 saivite appletalk client-mode
The following example configures IP-PPP on asynchronous interface 6. The IP address for the interface is assigned to Ethernet 0, interactive mode has been enabled, and the IP address of the client PC running PPP has been specified.
IP and the appropriate IP routing protocols have already been enabled on the access server or router.
interface async 6 ip unnumbered ethernet 0 encapsulation ppp async mode interactive peer default ip address 172.18.1.128
The following example shows how to configure IPX to run over PPP on an asynchronous interface. The asynchronous interface is associated with a loopback interface configured to run IPX. This example enables a non-routing IPX client to connect to the router.
ipx routing 0000.0c07.b509 interface loopback0 no ip address ipx network 544 ipx sap-interval 2000 interface ethernet0 ip address 172.21.14.64 ipx network AC150E00 ipx encapsulation SAP interface async 3 ip unnumbered ethernet0 encapsulation ppp async mode interactive async default ip address 172.18.1.128 ipx ppp-client loopback0 ipx sap-interval 0
In this example, IPX client connections are permitted to asynchronous interface 3, which is associated with loopback interface 0. Loopback interface 0 is configured to run IPX. Routing updates have been filtered on asynchronous interface 3. Routing updates take up a great deal of bandwidth, and asynchronous interfaces have low bandwidth.
The following example shows how to configure IPX to run over PPP on an asynchronous interface. A dedicated IPX network number has been specified for each interface, which can require a substantial number of network numbers for a large number of interfaces. This example permits an IPX client with routing enabled to connect with the router.
ipx routing 0000.0c07.b509 interface async 6 ip unnumbered ethernet0 encapsulation ppp async mode interactive ipx network AC150E00 ipx sap-interval 0
In this example, IPX client connections are permitted to asynchronous interface 6, which has a unique IPX network number. Routing updates have been filtered on asynchronous interface 6. Routing updates take up a great deal of bandwidth, and asynchronous interfaces have low bandwidth.
The following example shows how to enable IPX-PPP on VTY lines. First, you enable PPP to run on VTY lines, then you associate the VTY line with a loopback interface configured to run IPX. This example enables a non-routing IPX client to connect to the router.
ipx routing 0000.0c07.b509 interface loopback0 no ip address ipx network 544 vty-async ipx ppp-client loopback0
In this example, IPX client connections are permitted to VTY lines, which have been associated with loopback interface 0. Loopback interface 0 is configured with an IPX network number that is used by the VTY lines.
In the following example, asynchronous interface 7 and ethernet interface 0 are configured to enable NetBEUI connectivity between the corporate telecommuter's client and the remote access (NetBEUI) server. The PC client is running a legacy application---Chat---in Windows NT, to connect with the remote server. Refer to Figure 25.

The configuration for the router is as follows:
interface async 7 netbios nbf encapsulation ppp
You would also need to configure security, such as TACACS+, RADIUS, or another form of login authentication on the router.
The following example shows a simple configuration that allows routing and dynamic addressing. With this configuration, if the user specifies /routing in the EXEC slip or ppp command, routing protocols will be sent and received.
interface async 6 async dynamic routing async dynamic address
The following example configures async interface 7 with a default IP address, allowing header compression if it is specified in the slip or ppp connection command entered by the user or if the connecting system sends compressed packets.
interface async 7 ip address 172.31.79.1 async default ip address 172.31.79.2 ip tcp header-compression passive
The following example shows how to configure your router for routing using unnumbered interfaces. The source (local) address is shared between Ethernet 0 and async 6 (172.18.1.1). The default remote address is 172.18.1.2.
interface ethernet 0 ip address 172.18.1.1 255.255.255.0 ! interface async 6 ip unnumbered ethernet 0 async dynamic routing ! default address is on the local subnet async dynamic address async default ip address 172.18.1.2 ip tcp header-compression passive
The following example shows how the IP unnumbered configuration works. Although the user assigned an address, the system response shows the interface as unnumbered, and the address entered by the user will be used only in response to BOOTP requests.
router> slip /compressed 10.11.11.254 Password: Entering async mode. Interface IP address is unnumbered, MTU is 1500 bytes. Header compression is On.
In the following example, one of the asynchronous lines is used as the only network interface. The router is used primarily as a terminal server, but is at a remote location and dials into the central site for its only network connection.
ip default-gateway 10.11.12.2 interface ethernet 0 shutdown interface async 1 async dynamic routing ip tcp header-compression on async default ip address 10.11.16.12 async mode dedicated ip address 10.11.12.32 255.255.255.0
In the following example, the router is set up as a dedicated dial-in router. Interfaces are configured as IP unnumbered to conserve network resources, primarily IP addresses.
ip routing interface ether 0 ip address 10.129.128.2 255.255.255.0!interface async 1 ip unnumbered ethernet 0 async dynamic routing ! The addresses assigned with SLIP or PPP EXEC commands are not used except ! to reply to BOOTP requests.
! Normally, the routers dialing in will have their own address
! and not use BOOTP at all. async default ip address 10.11.11.254! interface async 2 ip unnumbered ethernet 0 async default ip address 10.11.12.16ip tcp header-compression passive async mode dedicated ! ! run RIP on the asynchronous lines, because few implementations of SLIP
! understand IGRP. Run IGRP on the ethernet (and in the local network). ! router igrp 110 network 10.11.12.0 ! send routes from the asynchronous lines on the production network. redistribute RIP ! don't send IGRP updates on the async interfaces passive-interface async 1 ! router RIP network 10.11.12.0 redistribute igrp passive-interface ethernet 0 ! consider filtering everything except a default route from the routing ! updates sent on the (slow) asynchronous lines distribute-list 1 out ip unnumbered async 2 async dynamic routing
In the following example, only the IGRP TCP/IP routing protocol is running; it is assumed that the systems that are dialing in to use routing will either support IGRP or have some other method (for example, a static default route) of determining that the router is the best place to send most of its packets.
router igrp 111 network 10.11.12.0 interface ethernet 0 ip address 10.11.12.92 255.255.255.0 ! interface async 1 async default ip address 10.11.12.96 async dynamic routing ip tcp header-compression passive ip unnumbered ethernet 0 line 1 modem ri-is-cd
The following configuration shows interface and line configuration. The interface is configured with access lists, passive header compression and a default address. The line is configured for TACACS authentication.
interface async 1 ip access-group 1 in ip access-group 1 out ip tcp header-compression passive async default ip address 172.31.176.201 line 1 login tacacs location 457-5xxx exec-timeout 20 0 password XXXXXXXX session-timeout 20 stopbits 1
Figure 26 illustrates a simple network configuration comprised of remote PCs with modems connected via modem to a router. The cloud is a public switched telephone network (PSTN). The modems are connected via asynchronous lines, and the access server is connected to a local network.
In this configuration you need to configure the following:

This default address indicates the address of the remote PC to the server, unless the user explicitly specifies another when starting the PPP session.
The server is configured for interactive mode with autoselect enabled, which allows the user to automatically begin a PPP session upon detection of a PPP packet from the remote PC; or, the remote PC can explicitly begin a PPP session by typing PPP at the prompt.
The configuration is as follows:
ip routing ! interface ethernet 0 ip address 192.168.32.12 255.255.255.0 ! interface async 1 encapsulation ppp async mode interactive async default ip address 192.168.32.51 async dynamic address ip unnumbered ethernet 0 line 1 autoselect ppp modem callin speed 19200
Figure 27 illustrates a network configuration that provides routing functionality, allowing routing updates to be passed across the asynchronous lines.
This network is comprised of remote and local PCs connected via modem and network connections to an access server. This access server is connected to a second access server via an asynchronous line running TCP/IP. The second access server is connected to a local network via modem.
For this scenario, you will need to configure the following:

The configuration is as follows:
interface async 1 encapsulation ppp async mode interactive async default ip address 192.168.32.10 async dynamic address ip unnumbered ethernet 0 async dynamic routing
If you want to pass IP routing updates across the asynchronous link, issue the following commands:
line 1 autoselect ppp modem callin speed 19200
Next, enter these commands to configure the asynchronous lines between the access servers, starting in global configuration mode:
interface async 2 async default ip address 192.168.32.55 ip tcp header compression passive
Finally, configure routing as described in the Network Protocols Configuration Guide, Part 1 using one of the following methods. The server can route packets three different ways:
1. Use ARP, which is the default behavior.
2. Use a default-gateway by issuing the command ip default-gateway x.x.x.x, where x.x.x.x is the IP address of a locally attached router.
3. Run an IP routing protocol (RIP, IGRP, EIGRP, or OSPF).
Figure 28 illustrates a scenario where two networks are connected via access servers on a leased line. Redundancy is provided by a dial-backup line over the public switched telephone network so that if the primary leased line goes down, the dial-backup line will be automatically brought up to restore the connection. This configuration would be useful for using an auxiliary port as the backup port for a synchronous port.
In this scenario, you will need to configure the following:

The configuration is as follows:
hostname routerA ! username routerB password cisco chat-script backup "" "AT" TIMEOUT 30 OK atdt\T TIMEOUT 30 CONNECT \c ! ! interface Serial0 backup interface Async1 ip address 192.168.222.12 255.255.255.0 ! interface Async1 ip address 172.16.199.1 255.255.255.0 encapsulation ppp async default ip address 172.16.199.2 async dynamic address async dynamic routing async mode dedicated dialer in-band dialer map IP 172.16.199.2 name routerB modem-script backup broadcast 3241129 dialer-group 1 ppp authentication chap ! dialer-list 1 protocol ip permit ! line aux 0 modem InOut rxspeed 38400 txspeed 38400
AS5200# modem at-mode 1/1 You are now entering AT command mode on modem (slot 1 / port 1). Please type CTRL-C to exit AT command mode. at%v MNP Class 10 V.34/V.FC Modem Rev 1.0/85 OK at\s IDLE 000:00:00 LAST DIAL NET ADDR: FFFFFFFFFFFF MODEM HW: SA 2W United States 4 RTS 5 CTS 6 DSR - CD 20 DTR - RI MODULATION IDLE MODEM BPS 28800 AT%G0 MODEM FLOW OFF AT\G0 MODEM MODE AUT AT\N3 V.23 OPR. OFF AT%F0 AUTO ANS. ON ATS0=1 SERIAL BPS 115200 AT%U0 BPS ADJUST OFF AT\J0 SPT BPS ADJ. 0 AT\W0 ANSWER MESSGS ON ATQ0 SERIAL FLOW BHW AT\Q3 PASS XON/XOFF OFF AT\X0 PARITY 8N AT
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Tue Jan 4 11:05:43 PST 2000
Copyright 1989-1999©Cisco Systems Inc.