|
|
CiscoWorks for Switched Internetworks (CWSI) Version 1.1 on AIX is a set of three network management applications: CiscoView, VlanDirector, and TrafficDirector. This document contains the release notes for each of the CWSI Version 1.1 on AIX applications and information that applies to CWSI Version 1.1 on AIX product in general. This document contains the following sections:
This section discusses the following CWSI Version 1.1 on AIX topics:
This section provides information about installing and configuring CWSI that is not located in the CiscoWorks for Switched Internetworks CD booklet.
![]() | Caution Carefully read the information in this section before installing and configuring CWSI. |
This section provides information on the following:
You can install CWSI from a CD-ROM drive attached to your system or from a drive connected to a remote host. However, before installing CWSI from a CD-ROM, you must first use the System Management Interface Tool (SMIT) to mount the local or remote CD-ROM drive on the local AIX system.
This section describes mounting from a remote CD-ROM drive. For information on mounting from a local CD-ROM drive, refer to the CiscoWorks for Switched Internetworks on AIX CD booklet.
To mount the CD-ROM on the local filesystem from a remote CD-ROM drive, perform the following steps on the remote system to which the CD-ROM drive is physically connected:
Step 1 Log in as root user and start SMIT by entering the following at the command prompt:
Step 2 On the System Management menu, select Physical & Logical Storage.
Step 3 Select File Systems and select Add/Change/Show Delete File Systems.
Step 4 Select CDROM File Systems.
Step 5 Select Add a CDROM File System.
Step 6 Click the "DEVICE name" List button and select the device name (such as /dev/cd0) from the list that appears.
Step 7 In the "Mount point" field, enter the name of a mount point directory (such as /cdrom).
Step 8 Click Do, read the output, and then click Done.
Step 9 Terminate SMIT by pressing F12 or by clicking Exit SMIT on the Exit menu.
Step 10 Enter the following at the command prompt:
Step 11 Click the "FILE SYSTEM name" List button and select a device name (such as /dev/cd0) from the list that appears.
Step 12 In the "DIRECTORY over which to mount" field, enter the name of a mount point directory (such as /cdrom).
Step 13 Click the "TYPE of file system" List button and select cdrfs as the file system type.
Step 14 Set the "Mount as Read-Only System" field to Yes.
Step 15 Click Do, read the output, and then click Done.
Step 16 Terminate SMIT by pressing F12 or by clicking Exit SMIT on the Exit menu.
Step 17 At the command prompt, enter smit mknfsexp.
Step 18 Enter the "PATHNAME of directory to export" (such as /cdrom).
Step 19 Using the arrow keys, change the "Mode to Export Directory" field to read-only.
Step 20 Enter information, if necessary, into any of the other fields.
Step 21 Click Do, read the output, and then click Done.
Step 22 Terminate SMIT by pressing F12 or by clicking Exit SMIT on the Exit menu.
After completing the steps on the remote system, perform the following steps on the local system:
Step 1 Log in as the root user.
Step 2 Enter the following command at the command prompt:
For example, to mount a remote filesystem name /cdrom from a host named zen, enter:
The CD-ROM is now ready for CWSI to be installed.
Replace the installation procedure documented in the "Installing the CWSI Applications" section of the CWSI CD booklet with the following procedure.
Before beginning installation, ensure that you have determined your installation and configuration path using the scenarios listed in the "Determining your CWSI Installation and Configuration Path" section in the CWSI CD booklet. CiscoView 3.1(1) is a prerequisite for the VlanDirector and TrafficDirector applications. If CiscoView 3.1(1) is not already installed, you will be prompted to install CiscoView before you install VlanDirector or TrafficDirector.
To install the CWSI applications:
Step 1 Insert the CWSI CD-ROM into the CD-ROM drive.
Step 2 Determine the contents of the CWSI CD-ROM by typing ls /cdrom. A file with a name similar to "cwsixxx.nnn" is displayed. Note the exact file name that is displayed because in Step 8 of this procedure you will enter the file name.
Step 3 Log in as the root user and start SMIT by entering the following at the command prompt:
Step 4 On the System Management menu, select Software Installation & Maintenance.
Step 5 On the next menu, select Install/Update Software.
Step 6 On the next menu, select Install/Update Selectable Software (Custom Install).
Step 7 On the next menu, select Install Software Products at Latest Available Level.
Step 8 In the Install Software Products at the Latest Available Level dialog box, type /cdrom/filename where filename is the name of the file that displayed in Step 2.
Step 9 Click List by the "SOFTWARE to install" field and select the CWSI application or applications that you want to install.
Step 10 Click OK and then Do.
Step 11 In response to the "ARE YOU SURE?" prompt, click OK to install the application or applications. SMIT installs the CWSI applications in the /user/nms directory and CWSI modifies SMIT to allow subsequent configuration and deinstallation of the CWSI application.
If the installation was successful, an OK status is displayed. If the installation was unsuccessful, a Failed status is displayed. If the reason for the failure is not apparent, read the installation log file $HOME/smit.log and, if necessary, contact the Cisco Technical Assistance Center (TAC).
Step 12 Click Done.
Step 13 If the installation was successful, click Return to System Management and proceed to the next section as mapped in the scenario you chose in the "Determining your CWSI Installation and Configuration Path" section.
If the installation failed, terminate SMIT by pressing F12 or by click Exit SMIT on the Exit menu.
To configure the VlanDirector application:
Step 1 On the System Management menu, click Communications Applications and Services.
Step 2 On the next menu, click Cisco Network Management Applications for AIX.
Step 3 On the next menu, click on VlanDirector.
Step 4 In the VlanDirector dialog box, click on Configure VlanDirector.
Step 5 Type or select the values for the following fields:
Step 6 To start the configuration process, click Do.
Step 7 In the VlanDirector dialog box, select Configure Empress Database.
Step 8 Type or select the values for the following fields:
Step 9 To start the configuration process, click Do.
Step 10 To terminate SMIT, press F12 or click Exit SMIT on the Exit menu.
Replace the procedure in the "Configuring TrafficDirector" section of the CWSI CD booklet with the following procedure.
To configure the TrafficDirector application:
Step 1 On the System Management menu, click Communications Applications and Services.
Step 2 On the next menu, click Cisco Network Management Applications for AIX.
Step 3 On the next menu, click on TrafficDirector.
Step 4 In the TrafficDirector dialog box, select Configure.
Step 5 In the TrafficDirector dialog box, type the values provided on the pink or yellow password form shipped with CWSI, or the permanent password that you have been assigned, in the following fields:
Step 6 Type or select values for the following fields:
Step 7 To start the configuration process, click Do.
The documentation for CWSI Version 1.1 on AIX includes this release note, and:
This section includes the following information about the CiscoView Version 3.1(1) on AIX release:
This section contains the latest Cisco Internetwork Operating System (Cisco IOS) software version information at the time of printing. New devices and further specifics on Cisco IOS software support will be announced following this release. Refer to the online release notes on Cisco Connection Online (CCO) or on the Cisco Connection Documentation, Enterprise Series CD, or Cisco Connection Documentation, CiscoPro Solutions CD, which are both accessible via CCO.
CiscoView Version 3.1(1) on AIX supports Cisco IOS Releases 10.0 through 11.1 with the exception of access servers, which require Cisco IOS Release 10.2.
Specifically, CiscoView on AIX supports the:
When you install and configure CiscoView Version 3.1(1) on AIX, the following files are stored in the $NMSROOT/install/bin directory where the NMSROOT is set to /usr/nms:
A successful installation and configuration of the CiscoView Version 3.1(1) on AIX product results in the following files being present on your system:
Absence of these files on your system indicates that the CiscoView Version 3.1(1) on AIX configuration was unsuccessful.
This section provides information on getting started with CiscoView on AIX.
The default IP Internet map includes all IP devices connected to NetView when NetView is started. To discover newly added or modified IP devices, use NetView's Options> Manage Objects command as follows:
Step 1 Click a device symbol on the default IP Internet map.
Step 2 Select Options> Manage Objects. NetView displays a submap of the selected device's children that are reachable in one hop. Newly appearing children could have been added to the network or explicitly unmanaged by a previous user. All newly appearing children devices are now accessible by CiscoView.
Step 3 Select File> Save Map As to save the database of devices you created.
For detailed information on how to run Options> Manage Objects, refer to the online help.
CiscoView's online help satisfies most of your information needs--there is no printed reference manual.
You can access CiscoView online help in the following ways:
CiscoView is a graphical user interface (GUI)-based device management software application that provides dynamic status, statistics, and comprehensive configuration information for Cisco Systems' switched internetworking products. CiscoView allows you to display a graphical representation of each network device, display configuration and performance information, and perform minor troubleshooting tasks.
The device packages provided with CiscoView Version 3.1.(1) on AIX software include support for the following Cisco devices:
With CWSI, CiscoView support has been extended for the CPW16, Catalyst 1200, Catalyst 3000, and Catalyst 5000. Support has also been added for the Catalyst 2900. The following are caveats for these devices in CiscoView:
You can perform the following routine maintenance functions for CiscoView:
You can also add new device and application support to CiscoView, by performing incremental installations.
The following procedures require that you use the IBM AIX system administrator facility, SMIT.
Device packages can be installed only after CiscoView has been configured as described in the "Configuring CiscoView" section in the CWSI CD booklet.
If you experience any corruption of your MIB database or the MIBs are not usable, you might want to consider reloading MIBs into NetView. The amount of time it takes to load MIBs into NetView depends on the number of MIBs being loaded.
To load MIBs into NetView:
Step 1 If you have not already done so, start SMIT by entering the following at the command prompt:
smit
Step 2 On the System Management menu, click Communications Applications and Services.
Step 3 On the next menu, click Cisco Network Management Applications for AIX.
Step 4 On the next menu, click on CiscoView.
Step 5 In the CiscoView dialog box, click Maintenance.
Step 6 In the Maintenance dialog box, click Load all MIBs into NetView.
Step 7 In response to the confirmation dialog box, click OK.
If the MIB files load successfully, an OK status is displayed. If loading failed, a Failed status is displayed. If loading failed, contact a TAC representative.
Step 8 To terminate SMIT, press F12 or click Exit SMIT on the Exit menu.
You can rebuild all CiscoView Version 3.1(1) on AIX configuration files if:
To rebuild all CiscoView files, follow this procedure:
Step 1 Enter the following at the command prompt:
smit
Step 2 On the System Management menu, click Communications Applications and Services.
Step 3 On the next menu, click Cisco Network Management Applications for AIX.
Step 4 On the next menu, click on CiscoView.
Step 5 In the CiscoView dialog box, click Maintenance.
Step 6 In the Maintenance dialog box, click Rebuild.
Step 7 In response to a confirmation dialog box, click OK.
If the rebuilding process is successful, an OK status is displayed. If the process failed, a Failed status is displayed. If the rebuilding process fails, contact a TAC representative.
Step 8 To terminate SMIT, press F12 or click Exit SMIT on the Exit menu.
To add new device and application support to CiscoView, access the Cisco Systems online support channel, Cisco Connection Online (CCO).
You must be running CiscoView Version 3.1 and later to do incremental installations. Open CiscoView and select Help>About CiscoView to check the version number.
To register on CCO, enter the following URL into your WWW browser:
http://www.cisco.com
If you are already registered, enter the following URL:
http://www.cisco.com/kobayashi/Library_root_shtml
Enter your CCO username and password. Continue to the section "Installing from CCO."
If you are not registered on CCO or do not have a SmartNet contract, you will need a special access code. Phone the Technical Support team for CiscoView at 800 553-2447 or 408 526-7209, or email tac@cisco.com, then enter:
http://www.cisco.com/public/library/spc_req.shtml
Enter the special access code and click Execute. Go to the section "Installing from CCO" before proceeding.
If you have a SmartNet contract, enter the following URL into your WWW browser:
ftp://[userid]@www.cisco.com/cisco/netmgmt/ciscoview/3.1.1/packages
For userid, substitute your own userid.
If you are not registered on CCO or do not have a SmartNet contract, you need a special access code. Phone the Technical Access Center (TAC) for CiscoView at 800 553-2447 or 408-526-7209, or email@cisco.com; then enter:
ftp://[special_access_code]@www.cisco.com/coded/
For special_access_code, substitute your own special access code.
For FTP server access, enter your email address as the password, for example, myname@net.com.
To get more information about the Partner Initiated Customer Accounts (PICA) program before accessing CCO for device package files, use the following URL:
http://www.cisco.com/acs/info/pica.html
To install devices incrementally on CiscoView Version 3.1(1) on AIX, use either of the following methods:
Step 1 If you have not already done so, start SMIT by entering the following at the command prompt:
smit
Step 2 On the System Management menu, click Communications Applications and Services.
Step 3 On the next menu, click Cisco Network Management Applications for AIX.
Step 4 On the next menu, click CiscoView.
Step 5 On the CiscoView menu, click Device Package Install Setup.
Step 6 In the field "Directory Containing Device Packages," enter the path where the device packages reside.
Step 7 In the "Load MIBs into NetView" field, the default is No. If you want to load MIBs, click the List button.
Step 8 If you performed Step 7, click Yes in the Single Select List dialog box to load MIBs into NetView.
Step 9 Click Do, wait for the process to complete, and read the output.
If the process was successful, an OK status is displayed. If the process failed, a Failed status is displayed. If the process failed, contact a TAC representative.
Step 10 Click Done and then Cancel.
This section provides information to help you troubleshoot problems associated with
CiscoView Version 3.1(1) on AIX.
When you perform an incremental installation of a CiscoView device package, the following log file is created on your system: $NMSROOT/cvinstall.log. Reviewing this log file may enable you to troubleshoot problems associated with the incremental installation.
If you cannot open a device in CiscoView, you will receive a message indicating that the device is unmanageable. This message indicates one of the following conditions:
This section lists notes and restrictions that apply to the CiscoView Version 3.1(1) on AIX release.
This section provides installation caveats.
The CiscoView installation puts the X Window SystemTM resource file for HyperHelp in the /usr/lib/X11/app-defaults directory. Because different systems have different types of X installations, the CiscoView application does not always read this resource file. When the resource file is not read, the HyperHelp viewer text may be unreadable on your screen. Do one of the following tasks to make sure that this resource file is read:
xrdb -merge /usr/lib/X11/app-defaults/HyperHelp
The following error message indicates that the program (for example, xrdb) is not in your path. Check your path environment variable. [CSCdi57661]
couldn't execute "xrdb": no such file or directory
If you are working off a CD-ROM mounted on a directory other than /cdrom or using a device other than /dev/cd0, you may have to set the environment variable I_CDROM_PATH to the directory to which the CD-ROM filesystem is mounted when loading device packages in CiscoView.
Multiple selections show all categories, whether they apply to a specific group of selections or not. If the category does not apply, the configuration table will show "N/A" in the cells. [CSCdi48854]
If you install CiscoView Version 3.1(1) on a machine where CiscoWorks 3.0.3 is already loaded, you must deinstall CiscoView and then install CiscoView Version 3.1(1).
If CiscoView 3.0(3) exists on your system, you must deinstall it first and then install CiscoView Version 3.1(1).
If an error message similar to "Cannot write to trapdconf file" is displayed when configuring CiscoView, ignore the message and continue the configuration process. The appearance of this message will not affect the configuration process.
This section provides deinstallation caveats.
Before deinstalling CiscoView Version 3.1(1) on AIX, the NMSROOT environment variable must be set on your system.
The general caveats are divided into six sections:
General notes and caveats for Enterprise Network Management products are described below.
Duplicate Definitions Message--If CiscoWorks is configured after CiscoView has been configured, a message that duplicate definitions exist may display when NetView is started. The recommended response to this message is to re-configure CiscoView as described in the "Configuring CiscoView" section of the CWSI CD booklet.
Dragging Ports--For this release, use the middle mouse button to drag on UNIX. Only certain devices (such as the Catalyst 1200, Catalyst 1600, Catalyst 5000, CPW 16) have defined their ports for dragging across devices.
NetView Discovery Issue--When a switch is configured as two or more domains, NetView discovery may not work properly and may discover only one of the domains. If this occurs, use CiscoView to manage the domain directly rather than launching it from the map.
NetView Error Message--The xnmloadmib program in NetView may have problems reloading MIB files into their database. The definition of CiscoNetworkProtocol in CISCO-TC-V1SMI.my and OwnerString in IF-MIB-V1SMI.my will display an error message similar to the following when you run cvinstall -f:
Error detected while loading MIB file: /net/cv311/etc/cview/mibs/CISCO-TC-V1SMI.my This MIB cannot be loaded until the following problem is corrected: Line 44613: Error defining ASN.1 Type: dupliCatalyste type with conflicting definition 'CiscoNetworkProtocol'
The workaround is to invoke xnmloadmib manually, select and unload all Cisco-specific MIB files from the list box in the xnmloadmib GUI, then run the command cvinstall -f to load all Cisco specific MIB files. [CSCdi56399]
Running CiscoView with Too Little Swap Space--If the server or display workstation is running out of swap space, you will see a message such as "X error: Couldn't allocate color cell," and CiscoView will core dump. If you are running other applications, you might want to check your swap space occasionally.
To check swap space on an AIX system, enter the following at the command prompt:
hostname% lsps -a
If your system is running out of swap space (for example, only 200 KB of swap space remains), quit some of the other applications you are running, or increase your swap space if possible. [CSCdi37063]
Running Out of Colors--CiscoView can run out of colors. If this occurs, CiscoView will continue to run, but all the colors it cannot allocate will dither to black or white. You can avoid this by starting CiscoView before starting color-intensive applications, or by using a private color map for the color-intensive applications (such as application_name -install).
Popup Menu Titles--Popup menu titles are raised; users may mistake them for menu items. [CSCdi53475]
Stripchart and Dials--The stripchart and CPU busy dials for 1 minute and 5 minutes are not drawn clearly for the 7513 router. [CSCdi51621]
Following are general notes and caveats that apply to the Cisco Workgroup family of products including the Catalyst 2800, Catalyst 2100, EtherSwitch 1200, and EtherSwitch 1400
Community String Mismatching--When the user enters values for the "read-only," "write-only," and "read-writeId" with the command-line interface (CLI) commands, these values must match. A mismatch results in "noSuchName" or "timeout" errors. To avoid these error conditions, use identical community strings in CiscoView and corresponding agents.
Exiting CiscoView Version 3.1(1) Causes Applications to Close--If you are using the CPW16 or Catalyst 3000 and close the CiscoView window, any application window that was launched from it will automatically close. Remember to close the EtherChannel and Domain Configuration application windows before you open another CiscoView application or exit from the CiscoView application. There is no limitation on the number of CiscoView applications that you can run.
False Error Reported After Setting Parameters--On the CPW16 and Catalyst 3000, when you try to set parameters for the EtherChannel/Domain application under moderate- to high-traffic situations, the application incorrectly displays an error window indicating that the operation was not successful. In reality, the command was successful, and you should dismiss the error dialog. The application should continue to function properly.
Next Button--If you rapidly press the Next button on the Catalyst 5000 port configuration dialog box, you may see some category names repeated twice. Redisplay the window to remove the duplicate names. [CSCdi57910]
ProStack Power Supply Link Problem--The rear view of the ProStack matrix power supply does not indicate whether the connector link is up or down (for example, the connector does not come up green if there is a link).
Switch Firmware--The following firmware versions must be used in the switches:
Switches--If you configure EtherChannel or Virtual Domains in Kalpana switch models EPS2015RS, EPS2115RSM, and Pro16 while running version 9.0 firmware with STP active, the map icons become red, and you receive the following error message:
No response from the device
After restarting the system, deactivate the shielded twisted-pair (STP) before you attempt to reconfigure. This problem is fixed in version 9.1 of the device firmware. [CSCdi41317]
Following are general notes and caveats for Cisco access products.
FDDI Port Status Functionality--The Cisco 4000 series devices with dual attachment station (DAS) FDDI ports show status on only the lower one of the two connectors. The status color is determined from the port's administrative status (ifAdminStatus) and operational status (ifOperStatus) values. [CSCdi28566]
Read-Only MIB Variables--The administrative status (ifAdminStatus) value "testing" and the ring speed (dot5RingSpeed) variable are implemented as "read only" in all Cisco IOS software versions and cannot be set through popup menus on CiscoView Configure Port screens. However, Configure Port tables (with multiple ports) offer popup windows that permit attempts to set these variables. Such attempts result in "Permission Denied" messages. [CSCdi50635]
Tunnel Interface--A "can't read 'port': no such variable" message appears at the bottom of the configuration port dialog box when a tunnel interface is encountered while you click up through the ports. This message can be ignored. [CSCdi55765]
Following are general notes and caveats for the Cisco high-end business suite of products (including the Cisco 7000 and Cisco 7500 series and ATM switches).
Displayed ATM Connector Type--CiscoView Version 3.1(1) on AIX always displays the multimode fiber SC type of ATM connector on ATM Interface Processors (AIPs), even when the media interface is another type. [CSCdi53420]
FDDI Port Status Functionality--For the Cisco 7000 and Cisco 7500 series routers running Cisco IOS Release10.2 or earlier, the displayed status color is determined from the port's administrative status (ifAdminStatus) and operational status (ifOperStatus) values. This status color will be the same on each connector. For devices running Cisco IOS Release 10.3 and later, the displayed status color is determined from the Port Connect State (fddimibPORTConnectState) for each connector. The possible values for this status and the corresponding status colors are listed in Table 1 [CSCdi28566].
| Status | Status Color |
|---|---|
| Disabled | Brown |
| Standby | Brown |
| Connecting | Blue |
| Active | Green |
High System Availability (HSA)--On the Cisco 7513 and Cisco 7507 chassis, when the master RSP (Route Switch Processor) is in use, the console port changes color on the CiscoView Version 3.1(1) display. However, when a slave RSP is installed, its console port mirrors that of the master, regardless of whether or not it is in use. [CSCdi49049]
In the HSA (dual RSP) configuration, invoking the Admin File Systems function gives an error message caused by a duplicate flash partition name ("slaveslot0") on the router. This error makes the File Systems functionality unavailable. The user should acknowledge the error message and close the "File Systems" window. [CSCdi54831]
LightStream 2020 MIB Support--For the LightStream 2020 there is currently no MIB support for the "LNS OK," "LN FLT," "BITS OK," and "TCS SEL" LEDs on front linecards. These LEDs appear blank. In addition, the "TX" and "RX" LEDs on front linecards blink too rapidly for SNMP polling purposes and also appear blank.
Lightstream 2020 Software Releases Supported--The LightStream 2020 supports Release 2.1(2) and later.
Online Insertion and Removal (OIR) Support--Hot swap is supported only on devices running Cisco IOS Release 11.0 and later. [CSCdi53447]
Power Supply Display--By default, CiscoView Version 3.1(1) on AIX displays two power supplies for a Cisco 7000 running Cisco IOS Release10.2 and earlier. With Release 10.3 and later, power supplies are displayed based on ciscoEnvMonSupplyState values (ENVIRONMENTAL MIB).
Read-Only MIB Variables--The administrative status (ifAdminStatus) value "testing" and the ring speed (dot5RingSpeed) variable are implemented as "read only" in all Cisco IOS software versions and cannot be set through popup menus on CiscoView Configure Port screens. However, Configure Port tables (with multiple ports) offer popup menus that permit attempts to set these variables. Such attempts result in "Permission Denied" messages. [CSCdi50635]
The following caveats are for online help.
Glossary Links--Some device-specific help files may not have links to the glossary file. To view the glossary, select Help>Using CiscoView in the help window.
Options Menu--The following information was omitted from the online help information for the Options menu:
Options>Set HyperHelp Defaults sets the HyperHelp resources so that the HyperHelp viewer text is readable on the screen. Options>Debug records trace information into a file loCatalysted in /tmp/.cvlog.
The VlanDirector Version 1.1 on AIX release works as documented in the VlanDirector User Guide with the exception of the items documented in the following sections:
For detailed information on VlanDirector, refer to the VlanDirector User Guide.
To find the version of VlanDirector, use the -V option instead of -v. The -v option is no longer available, as it is used internally by the TCL subsystem.
To save your customized views, you must start VlanDirector from a shell whose current working directory is one for which you have read-write access.
The online help for the VlanDirector Startup dialog box reverses the default values for community strings. It says private for Read and public for Read/Write, when the reverse is true.
The Ports window scroll bar does not always operate as expected, as shown in this example:
Step 1 Select a VLAN with at least one port, such as vlanX.
Step 2 Bring up the VLAN Ports window.
Step 3 Select the default VLAN or some other VLAN with many more ports than vlanX.
The scroll bar of the window does not change to reflect the greater number of ports in the newly selected VLAN.
Workaround: Either close the window and reopen it, resize the window, or turn Show: VLAN Ports off, then on again. The scroll bar then correctly reflects the number of objects displayed.
The initial size of the Help window is not wide enough to display the Find button.
Workaround: Resize the help window to at least 0.75 inches wider to display the Find button.
The Find window is displayed directly on top of the Help window and completely obscures it. This makes it appear that the Go To button in the Find window does not work.
Workaround: Move the Find window away from the Help window.
VlanDirector allows VLAN names up to 32 characters long, except when there are Catalyst 3000s in the network. (Catalyst 3000s only accept VLAN names up to 16 characters long.) VlanDirector does not take this into consideration when validating the length of a VLAN name.
Workaround: Make sure VLAN names do not exceed 16 characters in length if you have Catalyst 3000s in your network.
If you are running in a known network and you try to undo an action before a previous undo action is complete, you get this error message:
Immediate Network Operation Failed
If you click Help on this message, you get this further explanation:
Operation not the last in the undo list
Further, you can no longer open the undo list.
Workaround: Do not begin a second undo until the first one is complete.
In VlanDirector Version 1.0, the Read and Write community strings defaulted to public and private respectively. In VlanDirector Version 1.1, only the Read community string has a default value (public). Therefore, when you start VlanDirector without specifying a CSF or -wr, VlanDirector uses public for both the Read and Write community strings.
The following features will appear in the VlanDirector Version 1.2 release, to be used with Catalyst 5000 2.2 and Catalyst 3000 1.3:
The TrafficDirector Version 3.3 on AIX release works as documented in the TrafficDirector Windows User Guide with the exception of the items documented in the following sections:
For detailed information on TrafficDirector, refer to the TrafficDirector UNIX User Guide.
TrafficDirector is an RMON console software application that lets you monitor, troubleshoot, and record information about your network's operation. TrafficDirector helps you analyze network traffic patterns and identify and isolate a wide variety of fault conditions in data communications networks.
TrafficDirector works as a distributed system. It uses a central management console running TrafficDirector software in conjunction with data-gathering agents located at various points on a network. It can simultaneously collect wide-ranging statistical data, display selectively captured and fully decoded network traffic, set user-defined alarm conditions, and obtain real-time updates from all segments of a widely dispersed internetwork. TrafficDirector accomplishes this from a centralized, SNMP-compatible network management console.
TrafficDirector is based on two standards that enable it to operate in a multitopology, multivendor environment:
TrafficDirector has four main functions:
TrafficDirector gathers and analyzes network information using SwitchProbes and Cisco IOS software RMON agents attached to network segments.
TrafficDirector requires a serial number and password to unlock the software for use. A temporary evaluation serial number and password are attached to the shipping box. This serial number allows you to begin using TrafficDirector as soon as you receive it. However, you will need to request a permanent password before the evaluation expiration date. If you change the IP address of the host, or if you move the software to another machine, you must contact Cisco for a new password.
You can obtain a permanent license agreement through Cisco Connection Online (CCO) or by sending a fax to Cisco Systems.
To obtain a permanent license agreement through Cisco Connection Online, follow these steps:
Step 1 Access Cisco Connection Online at http://www.cisco.com.
Step 2 Access the Software Library. Enter the required information to generate your permanent password. Be sure to use the registration serial number and the registration password shipped with the software package.
To obtain a permanent license agreement by fax send a fax to Cisco Systems at 408 526-8898 addressed to "Attention: Software Licensing." Include the IP address of the machine on which you will be using TrafficDirector as well as your registration serial number and registration password shipped with the software package and a return fax number. You will receive your permanent password within 48 hours.
Table 2 lists the TrafficDirector for UNIX (Solaris, SunOS, HP/UX and IBM-AIX) configuration limitations:
| Configuration Parameter | Maximum Number Supported |
|---|---|
| Agents | 1000 |
| Agent groups | 100 |
| Agents per agent group | 60 |
| Interface number (ifIndex number) | 999 |
The Catalyst 1200 series switch embedded RMON agent and the SwitchProbe agents provide full seven-layer monitoring for all RMON groups. The Catalyst 2900 and Catalyst 5000 embedded RMON agents provide four groups of RMON (statistics, history, alarms and events) on all Ethernet and Fast Ethernet ports. The Cisco 2500 series routers with Cisco IOS Release 11.1 provide all nine groups of RMON as specified in RFC 1757.
The Group Switching Ethernet Module of the Catalyst 5000 supports 1 RMON agent on each of its 12-port segments for a total of 4 agents. Use only the ifIndex of the first port in each 12-port segment group when configuring the RMON agent from TrafficDirector.
The Catalyst 1200 DMP and NMP version 3.1 or higher include an embedded EnterpriseRMON agent. You need to purchase an agent license from Cisco before enabling this RMON agent. The embedded RMON agent cannot be configured to monitor the FDDI interface.
To use RMON within the Catalyst 1200 switch you must first create an agent and install domains for each interface that you wish to monitor. When configuring a new agent be sure to set the Interface Number field to a port number between 3 and 10, indicating which Ethernet port/segment you want to monitor. Also, be sure that the SNMP community strings in the Catalyst 1200 match those configured in TrafficDirector for each agent. Cisco ships the Catalyst 1200 with the following default community strings: Read = public,Write = private.
The Catalyst 1200 series switch reserves slightly less than 1 MB of RAM for use by the embedded RMON agent. Each enabled agent group within an installed domain consumes both memory and CPU cycles on the NMP to monitor that domain. You should remove any unused domains and only install the groups and domains that you plan to monitor. Use the memory consumption guidelines in Table 3 when configuring groups and domains:
| RMON Groups | Memory Used (bytes) | Assumptions |
|---|---|---|
| Statistics | 100 K | - - |
| Short History | 5 K | For 50 buckets |
| Long History | 5 K | For 50 buckets |
| Host Table | 25 K | For fewer than 256 hosts |
| Conversations (Metric Table) | 30 K | For fewer than 1024 conversations |
| Fully enabled domain | 75 K | Maximum (not including data capture buffer) |
Cisco Connection Online (CCO) is Cisco Systems' primary, real-time support channel. Maintenance customers and partners can self-register on CCO to obtain additional information and services.
Available 24 hours a day, 7 days a week, CCO provides a wealth of standard and value-added services to Cisco's customers and business partners. CCO services include product information, software updates, release notes, technical tips, the Bug Navigator, configuration notes, brochures, descriptions of service offerings, and download access to public and authorized files.
CCO serves a wide variety of users through two interfaces that are updated and enhanced simultaneously--a character-based version and a multimedia version that resides on the World Wide Web (WWW). The character-based CCO supports Zmodem, Kermit, Xmodem, FTP, Internet e-mail, and fax download options, and is excellent for quick access to information over lower bandwidths. The WWW version of CCO provides richly formatted documents with photographs, figures, graphics, and video, as well as hyperlinks to related information.
You can access CCO in the following ways:
http://www.cisco.com
WWW: http://www-europe.cisco.com
WWW: http://www-china.cisco.com
cco.cisco.com
For a copy of CCO's Frequently Asked Questions (FAQ), contact cco-help@cisco.com. For additional information, contact cco-team@cisco.com.
tac@cisco.com. To obtain general information about Cisco Systems, Cisco products, or upgrades, contact 800 553-6387, 408-526-7208, or cs-rep@cisco.com.

|
|