|
|
This chapter provides procedures for using CiscoView to perform Asynchronous Transfer Mode LAN Emulation (ATM LANE) configuration on Catalyst 5000 series switches. For LightStream 1010 ATM features, refer to Chapter 6, "ATM Features for the LightStream Switch."
Before you begin LANE configuration, you must decide whether you want to set up one or multiple ELANs. If you set up multiple ELANs, you must decide where the LESs and LECs will be located, and whether to restrict the LECs that can belong to each ELAN. Proceed to configure LANE.
Only the tasks pertaining to configuring Catalyst 5000 series switch are provided in the following sections.
To configure LANE, complete these steps:
Step 1 Review the following sections before proceeding:
Step 2 Create a LANE plan. Draw up a plan and a worksheet for your own LANE scenario. Determine the LANE components to use, their locations, their associated VLANs, and the necessary redundancy features. Leave space for noting the ATM address of each LANE component on each subinterface of each participating device.
Your plan should include the following information:
Step 3 Decide whether to set up one or multiple ELANs. If you set up multiple ELANs, decide where the LES/BUSs and LECs will be located and whether you will restrict membership of the LECs that can belong to each ELAN.
Step 4 Perform the steps listed in the section, "Configuring a LANE" to configure the LANE.
Step 5 Perform the steps listed in the section , "Checking ATM Configuration" to check the configuration.
The following rules apply to assigning LANE components to the major ATM interface and its subinterfaces:
The following configuration notes describe the configuration of a LANE on Catalyst 5000 series switches:
This section contains instructions for configuring a LANE, and includes the following sections:
Before you begin implementing LANE, be aware of the following:
You can display the default ATM addresses for the LECS, LES, BUS, and LEC. Perform these steps:
Step 1 Display the default LANE address and write down the address on the worksheet. Following is a list of locations for address information:
(a) LECS--go to the LECS Configuration window and write down the address listed in the Actual LECS Address: field.
(b) LES/BUS--go to the LES/BUS Configuration window and write down the address listed in the Actual LES, BUS ATM Addresses: field.
(c) LEC--go to the LEC Details window and write down the address listed in the LEC ATM Address: field. To display the MAC address, click Address Mapping, and write down the MAC address.
Step 2 Repeat Step 1 for each switch that participates in LANE and write down the displayed addresses on the worksheet.
Step 3 Click Cancel to exit the window.
This section contains instructions for performing the following:
On any Catalyst 5000 series switch, you can set up one or multiple LECS for multiple ELANs. You can set up an LECS for a given ELAN on any Catalyst 5000 series switch you choose to participate in that ELAN. After you set up the interface for the VLAN, you must link the VLAN number with the ELAN name.
To set up only an LECS for an ELAN, perform the following steps:
Step 1 From the LECS Management window, select the default database and click Create. The LECS Creation window opens.
Step 2 Specify the configuration for the LECS, including the following:
Step 3 Click Create to commit the input(s).
Step 4 Click Cancel to exit the window.
To configure a switch as the LECS for multiple ELANs with unrestricted membership, complete the following steps:
Step 1 From the LECS Management window, select the default LECS Database and click Configuration. The LECS Configuration window opens.
Step 2 Click LECS Database. The LECS Database window opens.
Step 3 Click Configuration. The Database Configuration window opens.
Step 4 Create a named database for the LECS and click Modify to commit the name.
Step 5 Click Cancel to exit the window and return to the Database Configuration window.
Step 6 Select the LES category and click Configuration. The Database Configuration--LES Category window opens.
Step 7 Bind the name of the first ELAN to the ATM address of the LES for that ELAN.
Step 8 Bind the name of the second ELAN to the ATM address of the LES.
Step 9 Repeat Steps 7 and 8, providing a different ELAN name and an ATM address for each additional ELAN in this switch cloud.
Step 10 (Optional) Specify a default ELAN for LECs not explicitly bound to an ELAN.
Step 11 Click Modify to commit the input in the window and exit the window.
When the database is set up for restricted-membership ELANs, create database entries that link the name of each ELAN to the ATM address of its LES.
However, you may choose not to specify where the LECs are located. That is, when setting up the LECS Database, you do not have to provide any database entries that link the ATM or MAC addresses of any LECs with the ELAN name.
Those LEC database entries specify the LECs allowed to join the ELAN. When an LEC requests the LECS to indicate which ELAN it is to join, the LECS consults its database and then responds as configured.
When LECs for the same restricted-membership ELAN are located in multiple switches, each LEC ATM or MAC address must be linked explicitly with the name of the ELAN. As a result, configure as many LEC entries (at Step 4, in the following procedure) as there are LECs for ELANs. Each LEC has a different ATM address in the database entries.
To set up the LECS for ELANs with restricted membership, perform the following steps:
Step 1 From the LECS Management window, click Database. The LECS Database window opens.
Step 2 Click Create. The LECS Database Creation window opens.
Step 3 Create a named database for the LECS, click Create to commit the name, exit the window and return to the LECS Database window.
Step 4 Click Configuration and select the LES category. The Database LES Configuration window opens.
Step 5 Use Create to bind the name of the first ELAN to the ATM address of the LES for that ELAN.
Step 6 Bind the name of the second ELAN to the ATM address of the LES.
Step 7 Repeat Steps 6 and 7, providing a different ELAN name and an ATM address, for each additional ELAN in this switch cloud.
Step 8 (Optional) Specify a default ELAN for LECs not explicitly bound to an ELAN.
Step 9 Add a database entry associating a specific LEC ATM address with a specific restricted-membership ELAN.
Step 10 Click Modify to commit the input in the window and exit the window.
Step 11 Repeat Steps 4 through 11 for each LEC with restricted-membership ELANs on this switch cloud. Specify the LEC ATM address and the name of the ELAN with which it is linked.
For each switch that participates in LANE, you must set up the necessary LES for each ELAN. BUSs are created automatically when the LES is created.
Once the LES and BUS have been set up, display and record the LES and BUS ATM addresses. Be sure to keep track of the interface where the LECS will eventually be located.
If there is only one default ELAN, you need to set up only one LES. If multiple ELANs are required, set up the LES for another ELAN on a different subinterface on the same interface--or place it on a different switch.
To set up the LES/BUS for an ELAN, complete the following steps:
Step 1 From the LES/BUS Configuration window, click Create. The LES/BUS Creation window opens.
Step 2 Specify the parameters for the first ELAN.
Step 3 Click Create to commit the change(s).
Step 4 Repeat Steps 2 and 3 for all other ELANs on this module.
Step 5 Click Cancel to exit the window.
Follow these steps to confirm configuration has been completed correctly.
Step 1 Select a module, and then select Configure>card. The Physical category information for the module is displayed. Verify the model displayed and the status fields associated with the model are correct.
Step 2 Select a port, and then select Configure>port. The Physical category information for the port is displayed. Verify the status fields associated with the port are correct.
Step 3 Select an ATM port, and then select Configure>port. The Physical category information for the port is displayed. Verify the ATM address information is displayed. Then, from the ATM Configuration menu, select the ELAN Table submenu and verify information on configured ELANs.
Step 4 Return to the CiscoView Main menu. Choose the Statistics menu. Display the message log information for the switch. Pay special attention to ATM type messages recorded in the log. If possible, screen capture the message log or make note of ATM related messages for future references.
Step 5 Clear the message log buffer using the Clear Logs command at the bottom of the message display log screen.
Step 6 If necessary, reconnect Catalyst 5000 series switch back into your network topology and channel the normal data flow back to them. If reconnecting the switches into your network, be sure the link LEDs are lit for each of the connected 10BaseT ports.
Step 7 Check your network health monitoring equipment (if available) to ensure the network is running cleanly. Check attached network devices for any obvious signs that the flow of data is being impeded.
Step 8 From each Catalyst 5000 series switch containing ATM modules, log back into the console, go to the Statistics menu, and display the message log. Pay special attention to ATM specific messages. Compare the ATM specific messages present in the log to the messages previously recorded. If needed, consult with Cisco support for an explanation of the different messages and their importance. Click Return to exit the display and return to the Statistics menu. Repeat this for each switch.
Step 9 From the CiscoView Main menu, select the whole device, select Configure>device, and access each of the Table categories to verify the address tables on each Catalyst 5000 series switch.
Step 10 Check the health of the network and the message log on each Catalyst 5000 series switches involved. If you see any irregularities are seen, investigate them immediately and, if needed, contact Cisco support.
After configuring LANE components on an interface or any of its subinterfaces, on a specified subinterface, or on an ELAN, display the LANE component status.
To show LANE status, perform the following steps:
Step 1 From the LECS Management window, click VC Connection to display the LES/BUS Creation window for the LECS configured on any interface. Due to space limitations, the ATM addresses for both parties of a selected VC Connection entry are displayed when you click Details in the LES/BUS Creation window. This displays the LES/BUS Creation window.
Step 2 From the LECS Management window, click Creation to display the LES/BUS Creation window, and then click LECS Database to display the LECS Database window. From the LECS Database window, select each of the categories to display the configuration window for each category.
Step 3 From the CiscoView Main menu, select the device, and then select Configure>device>ARP Table category to display the LANE ARP table of the LEC configured on the specified subinterface or ELAN.
|
|