|
|
Return codes are mapped to error messages in the file PSErrorMap.properties, located in the java/cls/frontend subdirectory of your CIPM installation.
| Return Code | Message Text |
|---|---|
0 | Successful |
1001 | The operation is not allowed for the user - permission denied |
1002 | Database has run out of space |
1003 | Supplied identifier has illegal characters |
1004 | One or more of the parameters are not assigned a value |
1005 | Input string is too long |
1006 | Authorization server is down |
1007 | Telnet Gateway server is down |
1008 | SNMP gateway server is down |
1009 | Network Administration server is down |
1010 | Failed to create a new thread. A system limit is exceeded. |
20001 | Server internal error |
| Return Code | Message Text |
|---|---|
2001 | Environment variable EXPECT_SCRIPT_ROOT is not defined |
2002 | Telnet Module failed to fork Expect interpreter |
2003 | Could not enter element privileged command mode - check enable username and password |
2004 | Could not read file from tftpserver |
2005 | Could not enter element privileged command mode |
2006 | Unable to connect to element - element did not respond, check network element attributes or element physical connection or customized prompt setting |
2007 | Unable to configure element - check tftpserver connection and tftp directory write permission |
2008 | No element specified in telnet session |
2009 | This Telnet Gateway service is not implemented |
2010 | Erase command error |
2011 | Write memory command error |
2012 | Reload command error |
2013 | IOS command execution error |
2014 | Show command error |
2015 | Expect interpreter error |
2016 | Element object already exists |
2017 | Element operation did not complete within given time interval |
2018 | Get Communication Agent Attributes error |
2019 | Set Communication Agent Attributes error |
2020 | Show command failed - check privilege |
2021 | IOS command failed |
2022 | Get Element attributes error |
2023 | Missing required entries |
2024 | Download successful, but IOS parser may have found errors |
2025 | Unable to connect to terminal server - terminal server did not respond, check connected host ip address |
2026 | Element object does not exist |
2027 | Unable to perform operation by using VTY - use console instead |
2028 | Unable to connect to element - check login password |
2029 | Unable to connect to terminal server - check login password |
2030 | Unable to connect to element - check login username and password |
2031 | Unable to connect to terminal server - check login username and password |
2032 | Unable to connect to element - terminal server port is in use |
2033 | Unable to enter element privileged command mode - check enable password |
2034 | Invalid console port number |
2035 | Telnet process did not respond within given time interval - operation may not complete. |
2036 | Unable to configure element using tftp transfer within given time interval |
2037 | Configuration file is too big - check nvram size |
2038 | Telnet process status lost due to socket communication error - check socket port usage by other applications in your system |
2039 | No socket available for Telnet Gateway operation |
2040 | Bad terminal server port password |
2041 | Parameter error in call to Telnet Gateway function |
2042 | Error reading TGServer configuration file |
2043 | Error writing TGServer configuration file |
2044 | Local storage device: file-not-found error |
2045 | Local storage device: no-space-on-device error |
2046 | Local storage device: device-not-available error |
2047 | Local storage device: unspecified file I/O error |
2999 | Telnet module error |
| Return Code | Message Text |
|---|---|
3001 | ADM internal error |
3002 | Unknown user |
3003 | User already exists |
3004 | Incorrect password |
3032 | User unknown, or may not be member of any group |
3005 | Unknown group |
3006 | Group already exists |
3007 | User is already member of a group |
3008 | Unknown resource identifier |
3009 | Unknown resource identifier or specified bad input permissions |
3011 | ADM Server - service level failure |
3010 | Server discovered some bad or inconsistent data in database |
3012 | No permissions to keep an element in "Root" domain |
3013 | No group can get delete permission on "Root" domain |
3014 | Unknown element type |
3015 | Invalid parameter passed to ADM API |
3016 | No element operation under the Root domain |
3017 | Error in checking domain access permission |
3018 | Tried to delete a domain with child exists |
3019 | Tried to operate on a locked element |
3020 | Domain already exists |
3021 | Network element already exists |
3022 | Tried to delete a domain whose both assigned NEM servers are down |
3023 | Specified object not found |
3024 | NEM server not found |
3025 | Domain not found |
3026 | NEM server is down, not reachable |
3027 | Cannot change a Network Element Manager server that is in-use! |
3028 | Cannot change a Network Element Manager server status that is down |
3029 | This user is not a superuser |
3033 | Invalid parameter passed to ADM API |
3034 | No such attribute in user profile |
| Return Code | Message Text |
|---|---|
6002 | Template already exists |
6003 | Template does not exist |
6004 | Template data already exists |
6005 | Template data does not exist |
6006 | Template data is not attached to any Template |
6007 | Attribute encoding error |
6008 | Error during generation of configuration |
6009 | Error when template is included in itself |
6010 | Subtemplate cannot be included in the template (hierarchy violation) |
6011 | Data encoding is not correct in data file |
6012 | Object is locked by a user, preventing services on it |
6013 | Template deletion request rejected if it has template data objects |
6014 | Config generation - A subtemplate object is not found |
6015 | Config generation - Some template data objects are not used |
6016 | Config generation - No network element configuration in template data object(s) |
6017 | Config generation - Some attributes are not present in the template body |
6018 | Config generation - Some attribute values are missing in the spreadsheet |
6019 | Config generation - Subtemplate has another included template (no support) |
6020 | Subtemplate belongs to a different model than the Master |
6050 | Fatal error accessing persistent information (/unknown object?) |
6051 | Fatal error creating persistent information (/invalid object parameters?) |
6052 | Fatal error deleting persistent information (/unknown object?) |
6053 | Fatal error modifying persistent information (/invalid parameters?) |
6901 | Error in locating Authorization and Access Server (AAS) |
6902 | Error in locating Network Administration Manager (NAM) server |
6903 | Authorization and Access Server (AAS) is not available |
6904 | Network Administration Manager (NAM) server is not available |
6905 | Bad Authorization and Access Server (AAS) reference from Naming Service |
6906 | Bad Network Administration Manager (NAM) server reference from Naming Service |
6907 | This error code is reserved internally - please report it to the vendor |
6908 | Service request to Network Administration Manager (NAM) server failed |
6909 | Service request to Authorization and Access Server (AAS) failed |
| Return Code | Message Text |
|---|---|
7001 | Unknown user group |
7002 | Unknown element type |
7003 | One or more of the parameters are not assigned a value |
7004 | Root operation is not allowed |
7005 | Access authorization failure - please check server status |
7006 | Element data inconsistent |
7007 | Cannot create Element |
7008 | Cannot delete Element |
7009 | Element reference count is not zero |
7010 | Object already exists |
7011 | Element already exists in this container |
7012 | Tried to operate on an element which is locked by another operation |
7013 | Element already exists |
7020 | Object not found |
7021 | server required by Network Element Manager not found |
7022 | Element not found |
7023 | Configuration file not found |
7024 | Configuration file is empty |
7030 | Network Element Manager received an internal exception |
7031 | Network Element Manager received an exception from Telnet Module |
7032 | Exception while get element list |
7040 | Cannot get IOS version |
7041 | Not super user |
7050 | Host IP address entry error while set element attribute |
7051 | Term server entry error while set element attribute |
7052 | Connection type entry error while set element attribute |
7053 | Can not change username and password prompt |
7054 | Operation not allowed. Maybe Element is decommissioned. |
7999 | Network Element Manager (NEM) internal error |
| Return Code | Message Text |
|---|---|
10001 | File not found |
10002 | Label not found |
10003 | Invalid file type |
10004 | Cannot append this file to a label because the file type is different |
10005 | This label already exists |
10006 | File is already checked out |
10007 | This file is checked out by another user |
10008 | File is not checked out |
10009 | File type already exists |
10010 | File type not found |
10011 | Cannot delete the system-defined file type |
10012 | Cannot locate some files during labeling process |
10013 | Cannot access temporary file |
10014 | Failed to check in because the content is the same as the previous version |
10015 | There is no change on running config based on the flag in NEM |
10016 | There is no change on startup config based on the flag in NEM |
10017 | Some of the operations failed |
10999 | VCM internal error |
| Return Code | Message Text |
|---|---|
11001 | SGS:Internal error. |
11002 | SGS:Duplicate entry. |
11003 | SGS:Entry not found. |
11004 | SGS:Timeout error. |
11005 | SGS:Invalid input parameter. |
11006 | SGS:Download configuration failed. |
11007 | SGS:Upload configuration failed. |
11008 | SGS:File I/O error. |
11009 | SGS:Memory error. |
11010 | SGS:Network Device error. |
11011 | SGS:TFTP error. |
11012 | SGS:Operation not supported. |
11013 | SGS:Operation failed. |
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Mon Feb 14 14:06:10 PST 2000
Copyright 1989 - 2000©Cisco Systems Inc.