|
|
Cisco WAN Manager 9.2.09 for Solaris software supports the following Cisco products:
Cisco WAN Manager (CWM) is the new name of the former product, Cisco StrataView Plus (SV+). As of CWM release 9.2.00, all references to SV+ were changed to CWM, including the start-up script, the desktop, and icon names.
The CWM 9.2.09 release is fully Year 2000 (Y2K) compliant. Table 7 lists the compliance matrix.
CWM 9.2.09 is bundled with WANCV 2.09 (WAN switching device packages) for device management.
This Release Notes document contains the following sections:
Three types of machines are supported for WAN Manager 9.2.09 as standard platforms. They are low-end, mid-range, and high-end platforms. The configuration of each platform type is listed in Table 1, "Sun Platform Requirements".
| Platform Type | Machine Type | Number of CPUs | Size of RAM | Graphic Card Type | Hard Disk Drive | Swap Space | Desktops Supported (n) | Connections Supported (m) |
|---|---|---|---|---|---|---|---|---|
Low End | Sun Ultra Enterprise 1 Model 170 or Sparc 20 Model 151 or Ultra 10 with SCSI controller | 1 | 256 MB | 24 bits | One 2 GB + one 4 GB drives | 512 MB | Less than 5 | Less than 5,000 |
Mid Range option 1 | Sun Ultra Enterprise 2 Model 2300 or Ultra 30 model 300 | 1 (300 MHz processor) | 512 MB | 24 bits | Two 4 GB drives or 1 9 GB drive | 1 GB | 5 - 10 | 5,000 - 25,000 |
Mid Range option 2 | Sun Ultra Enterprise 2 Model 2300 or Ultra 60 | 2 (300 MHZ processors) | 512 MB | 24 bits | Two 4 GB drives OR 1 9 GB drive | 1 GB | 5 - 10 | 25,000 - 50,000 |
Mid Range option 3 | Sun Ultra Enterprise 2 Model 2300 or Ultra 60 | 2 (300 MHZ processors) | 1 GB
| 24 bits
| Two 4 GB drives OR one 2 GB + one 9 GB drives | 2 GB | 5 - 10 | 50,000 - 100,000 |
High End | Sun Enterprise 4000 or Enterprise 450 | at least 4 | 1 GB | 24 bits | One 4 GB drive + one 9 GB drives or disk array | 2 GB | More than 10 | More than 100,000 |
The selection of a proper CWM platform depends on a number of factors, such as, the number of CWM desktops, the number of managed connections, and the number of statistics collected and stored. Table 2 lists recommended CWM platforms based on the size of network.
The following are additional notes for CWM platform requirements:
If you use CWM 9.2.09 on a low end machine to manage mid-range or large-range networks, the following performance problems might be observed.
CWM may take a long time to synchronize with the network. Connection Management and Equipment Management (CiscoView and Equipment Manager GUI) may take long time to come up or perform any user-requested functions. You might not be able to invoke multiple Desktops from CWM as certified by Cisco for low-end systems.
CWM may drop traps generated by the network which might put the CWM database out of sync with the network. This would result in the information about nodes, trunks, ports, and PVCs might not match with the status on the network.
Three types of machines are supported for CWM 9.2.09 stand-alone SCM as standard platforms. They are low-end, mid-range, and high-end platforms. The configuration of each platform type is listed in Table 2. Other equivalent platforms running Solaris 2.6 are also supported.
| Platform Type | Machine Type | Number of CPU | Size of RAM | Hard Disk Drives | Swap Space |
|---|---|---|---|---|---|
Low End | Sun Ultra Enterprise 1 Model 170 or Sparc 20 | 1 | 128 MB | One 2 GB drive | 256 MB |
Mid Range | Sun Ultra Enterprise 2 Model 2000 or Sun Ultra-30 | 1 | 256 MB | One 2 GB drive | 512 MB |
High End | Sun Ultra 60 | 2 | 512 MB | One 2 GB drive | 1 GB |
The CWM 9.2.09 release works with HP OpenView Release 5.01 for Solaris 2.6. See "Third Party Product Limitations Notes" for HP OpenView patches required by CWM.
The default color of the background map can make it difficult to see the color of the nodes and the trunks on the map.
For HP OpenView installation requirements and procedures, please refer to "HP OpenView Network Node Manager Products, Installation Guide" (part # J1136-90000 from HP).
The CWM 9.2.09 release uses Informix 7.23 for database operations.
The CWM 9.2.09 release's Report Application uses WingZ 2.5 or later. For the Report Application to work properly, the DataLink package of wingZ must also be installed along with WingZ package.
This section provides information about the hardware supported by CWM 9.2.09.
Table 3 lists the legacy hardware supported in CWM 9.2.09.
| Platform Series | Front Card | Back Card | Firmware Version | Software Version |
|---|---|---|---|---|
IGX 8400 | NPM | SCM | CVJ,CWP | 9.2.33 |
IGX 8400 | NTM | BC-T1/E1/SR/Y1 |
| 9.2.33 |
IGX 8400 | BTM | AIT-T3/E3/E2/HSS1/E1 | AJF,BCF,BDK,BDL | 9.2.33 |
IGX 8400 | FRM | FRI-T1/E1/V.35/X.21 |
| 9.2.33 |
IGX 8400 | FTM | FPC-V35/T1/E1/X.21 |
| 9.2.33 |
IGX 8400 | HDM | V.35/RS-449/RS-232C/RS-232D | CEF | 9.2.33 |
IGX 8400 | LDM | RS-2324/RS-2328/RS-232D |
| 9.2.33 |
IGX 8400 | CVM | BC-T1/E1/J1/Y1/SR | AFF,AHF,BHC | 9.2.33 |
IGX 8400 | UVM | UVI-2T1EC/2E1EC |
| 9.2.33 |
IGX 8400 | UFM-C | UFI-8T1/8E1-DB15,UFI-8E1-BNC |
| 9.2.33 |
IGX 8400 | UFM-U | UFI-V35/X21/HSI |
| 9.2.33 |
IGX 8400 | ARM | ARI | BA | 9.2.33 |
IGX 8400 | UXM | UAI-4OC3MMF/40C3SMF/2OC3SMF/6T3/6E3/3T3/3E3/8T1-IMA/8E1-IMADB15/8E1-IMABNC | AAB,ENW,P0512 | 9.2.33 |
BPX 8600 | BCC | BCC-bc/3-bc | B0406,BKF,BKJ,BMH,BYJ | 9.2.33 |
BPX 8600 | ASM | LM-ASM | AAA,ABA,ACA,BC03 | 9.2.33 |
BPX 8600 | BNI-T3 | LM-3T3 | CCJ,CEL,CHD,CHF | 9.2.33 |
BPX 8600 | BNI-E3 | LM-3E3 | CFD,CFF,CLF | 9.2.33 |
BPX 8600 | BNI-155 | LM-OC3-SMF/SMFLR/MMF |
| 9.2.33 |
BPX 8600 | ASI-1 | LM-2T3/2E3 | BDK,BFJ,BXJ | 9.2.33 |
BPX 8600 | ASI-155 | LM-2OC3-SMF/SMFLR/MMF | CB30,HFA | 9.2.33 |
BPX 8600 | BXM-T3/E3 | BPX-T3/E3-BC |
| 9.2.33 |
BPX 8600 | BXM-15 5 | MMF/SMF/SMFLR-155 | DC1,DL1 | 9.2.33 |
BPX 8600 | BXM-622 | MMF/SMF/SMFLR-622 |
| 9.2.33 |
MGX 8220 | FRSM-4P | DB-15-4T1/4E1, BNC-4E1 |
|
|
MGX 8220 | CESM-4P | DB-15-4T1/4E1, BNC-4E1 |
|
|
MGX 8220 | AUSM-4P | DB-15-4T1/4E1, BNC-4E1 |
|
|
MGX 8220 | FRSM-8P | RJ48-8T1/8E1, SMB-8E1 | 5.0.12, 5.0.13, 4.0, 4.1.07 |
|
MGX 8220 | AUSM-8P | RJ48-8E1/8T1 | 5.0.12, 5.0.13, 4.0, 4.1.07 |
|
MGX 8220 | CESM-8P | RJ48-8T1/8E1, SMB-8E1 | 5.0.12, 5.0.13, 4.0, 4.1.07 |
|
MGX 8220 | IMATM-B | RJ48-T3T1/E3E1/E3T1/T3E1 | 5.0.12, 5.0.13, 4.0, 4.1.07 |
|
MGX 8220 | FRSM-HS1 | HSI-4X21/3HSSI | 5.0.12, 5.0.13, 4.0, 4.1.07 |
|
MGX 8220 | BNM-T3/E3 | T3E3-B/D | 5.0.12, 5.0.13, 4.0, 4.1.07 |
|
MGX 8220 | BNM-155 | 155-SMF |
|
|
MGX 8220 | SRM | DB-15-T1/E1, LM-3T3 |
|
|
MGX 8220 | ASC | ASC-LM | 5.0.12, 5.0.13, 4.0, 4.1.07 |
|
Table 4, "Supported New Hardware", lists the new hardware supported in CWM 9.2.09.
| Platform Series | Front Card | Back Card | Firmware Version | Software Version |
|---|---|---|---|---|
MGX 8220 | FRSM-VHS | HS2 | 5.0.12 |
|
MGX 8220, 8850 | AUSM model B | 8T1/E1 | 5.0.12 |
|
MGX 8850 | PXM1 | T3/E3/OC3/OC12 | 1.1.24 |
|
MGX 8850 | FRSM-VHS | HS2/T3/E3/CT3 | 10.0.11 |
|
MGX 8850 | FRSM-8P | RJ48-8T1/8E1, SMB-8E1 | 10.0.11 |
|
MGX 8850 | CESM-8P | RJ48-8T1/8E1, SMB-8E1 | 10.0.11 |
|
MGX 8850 | RPM | 10mbps/100mbps | 12.0(6.0.2)T, 12.0(5)xT1 |
|
MGX 8850 | SRM | LM-3T3 |
|
|
MGX 8850 | VISM | 8T1/8E1 | 1.5 (5) |
|
CWM 9.2.09 operates with BPX 8600 and IGX 8400 series systems running SWSW releases 9.2 or 9.1. It does not support IPX nodes running SWSW release 9.1. CWM 9.2.09 operates with MGX 8220 releases 4.0, 4.1, and 5.0 for all supported features. CWM 9.2.09 can operate in mixed networks of 9.1 and 9.2 SWSW.
WANCV 2.01 will operate with BPX/IGX releases 9.2 and 9.1, releases of MGX 8220 later than 4.0.15, and all available releases of MGX 8850. You should use CWM Equipment Manager to manage MGX 8220 release 4.0.15 and earlier releases. When you launch Equipment Manager from the CWM Desktop, the application determines whether to launch WANCV or CWM Equipment Manager.
Cisco strongly recommends you use CiscoView Release 4.2 with all available Software Module Updates. WANCV 2.09 device packages are also compatible with CiscoView Release 4.1.
All event messages are now displayed in the HPOV Event Browser window. There is a limit of 2000 pending messages on the Event Browser. If there are more than 2000 messages to be processed and displayed by the Event Browser, it may exit.
Patch PSOV_02243 is required for HPOV and is supplied on the CWM 9.2.09 CD. If HP OpenView is installed on your CWM station, this patch is installed during CWM 9.2.09 installation.
The WANCV 2.0 release works with HP OpenView Release 5.01 for Solaris 2.6.
For HP OpenView installation requirements and procedures, refer to "HP OpenView Network Node Manager Products, Installation Guide" (part # J1136-90000 from HP).
Cisco WAN Manager 9.2.09 has been enhanced to recognize the MGX 8230 and MGX 8250 model numbers, to support VISM 1.5.5, the RPM 400, and to support the BXME on Cisco BPX 8600 series and add CiscoView support for Cisco IGX 8400 series wide area switches running Release 8.5. The following CWM components have been enhanced:
Cisco WAN Manager 9.2.08 has been enhanced to support VISM 1.5 and to provide QBIN statistics enhancements for Cisco BPX 8600 series and Cisco IGX 8400 series wide area switches. The following CWM components have been enhanced:
Cisco Wan Manager 9.2.07 has been enhanced to support the following features of switch software release 9.2.30:
| Service MIB | AXIPOP (switch) MIB |
|---|---|
frEndPointEgressQselect | egressQselect |
svCardEgrQOSFeature | egrQoSFeature |
svFrAXPortSvcRatio | portEqueueServiceRatio |
The following new features and enhancements are new for CWM 9.2.06:
CWM 9.2.06 supports the additional connection types listed in Table 6.
| Connection Type | CWM Service Type | Local Service Module | Remote Service Module | Feature |
|---|---|---|---|---|
ATM-ATM | abr.fs | AUSM | BXM, | Allows independent specification of UPC PCR01 and ForeSight PIR on AUSM endpoints. |
ATM-FR | abr.fs | AUSM | FRSM, | Allows independent specification of UPC PCR01 and ForeSight PIR on AUSM endpoints. |
ATM-ATM | cbr.1 | AUSM/PXM | AUSM, | Allows disabling of entire UPC function at AUSM |
CWM 9.2.05 has the following new features and enhancements.
CWM 9.2.04 had the following new features and enhancements.
"OAM Loopback Allowed?" = rasOamlpbkAllowed
This object indicates if the RAS-OAM loopback test is enabled for this card. {rasOamlpbkEnabled(1), rasOamlpbkDisabled(2)}
"OAM Loopback Frequency" = rasOamlpbkFrequency
This object indicates the frequency in minutes (1..10) in which a RAS OAM loopback cell is sent per idle connection.
CWM 9.2.03 had the following new features and enhancements.
CWM 9.2.02 had the following new features and enhancements.
CWM 9.2.01 had the following new features and enhancements.
You can maintain unique node IDs across all CWM databases using the Topology Configurator feature of the CWM Admin application on the CWM Desktop.
CWM 9.2.00 supports an MGX 8850 node configured as a standalone switch which does not connect to any Cisco MSSBU switch. In this mode, you must use the Topology Configurator to enter node-related information into the CWM database. The following CWM applications are enhanced to support standalone MGX 8850:
| Software | Release | Patch | Compliance Certified By | Comments |
|---|---|---|---|---|
Cisco WAN Manage | 9.2.06 | n/a | Cisco Systems 29 Test Case suite |
|
HP OpenView | 5.01 | PSOV-02091, PSOV_02208 | Hewlett Packard |
|
WingZ | 2.5 | n/a | IISC |
|
Informix | 7.2.3.UC4 | n/a | Informix |
|
Solaris OS | 2.6 | Solaris 2.6 Recommended Patch Cluster, dated Jan. 14, 1999 and Solaris 2.6 Y2000 Patch Cluster, dated Jan. 4, 1999. | Sun Microsystems | These patch clusters can be downloaded from http://sunsolve.sun.com/pub-cgi/usr/pubpatchpage.pl |
Features related to VISM 1.5 (5) maintenance release are available in this build for the MGX88 package. These new features are as follows:
CiscoView MSSBU device packages (WANCV) are upgraded to release 2.0 to support IGX/BPX Release 9.2.00, MGX 8220 Release 5.0 enhancements, and the MGX 8800 family of products.
The following features are not supported in CWM 9.2.09:
The SWSW and MGX 8220 (4.04 onwards) have increased their limits to support network connections of up to twelve CWM stations. No changes were required in Cisco WAN Manager Release 9.2.09 software to support this increase.
CWM can manage up to 40 different disjoint networks running switch software releases 9.1 and 9.2, provided all the networks elements have unique network IP addresses and unique names across all the networks managed by CWM. Different networks may run different versions of switch software as long as the releases are those listed above. Disjoint networks containing up to 15 nodes in each network have been tested.
CWM 9.2.09 was only tested up to 250 nodes in the field for the statistics collection application.
In CWM 9.2.09, the Connection Manager GUI performs the SCR range check based on the card family and takes the intersection of all individual ranges of each card type in the card family. Consequently, some SCR values might not be configurable from Connection Manager GUI. However, it is configurable from command line interface. This limitation will be fixed in CWM 10.
In this case, you will see following error message when you attempt to modify the SCR using unsupported value.
Field: SCR: The field you entered has a range of 10 to 1412830. Please re-enter the field.
Due to the nature of asynchronous behavior of ILOG client and server interaction, it is likely to have CWM client requests made before the CWM server is ready. In this case, the following error messages will be displayed on the workstation screen:
Ilb Error: Synchronous request to <unidentified actor failed by timeout>. However, if the ILOG timeout situation persists for more than five minutes, the CWM station is not functioning normally, and a service call should be made.
The CWM network browser does not support the access restriction imposed by the CWM security manager. For example, the CWM administrator can create a user profile which restricts the access to cards. However, that user is still able to see all cards in the network browser application.
CWM network browser does not support the access restriction imposed by the CWM security manager. For example, the CWM administrator can create a user profile which restricts the access to cards. However, that user is still able to see all cards in the network browser application.
RPMs using IOS version 12.0(4) have slot numbers in its ifDescr that are unlike those for IOS version 12.0(5). This invalidates the enhancement for IOS version 12.0(5) in CWM 9.2.09 and WAN CiscoView 2.0.9, and it makes RPMs using IOS version 12.0(4) unmanageable by CiscoView.
The workaround for this problem is to upgrade RPM using IOS version 12.0(4) to version 12.0(5).
The upgrade script has changed in Cisco WAN Manager Release 9.2.09.
Existing CWM configuration files are unconditionally overwritten with default values during the CWM 9.2 installation process. If you are installing CWM 9.2.09 over an earlier release of CWM 9.2.0x, save these files manually before beginning the installation process. The following files are affected:
Make sure at least 900 MB of disk space in the /usr/users/svplus area can be allocated for CWM 9.2.09 installation. In the case of an upgrade, the disk space used by the existing CWM software plus free disk space should exceed 900 MB.
If you plan to use auto install and you intend to partition the disk during auto install, you have two choices for installing the WingZ application:
1. Install WingZ in /opt/Wingz before installing CWM and then execute IntegrateWingz.
2. Install WingZ in /usr/users/Wingz after installing CWM and then execute IntegrateWingz.
If you do not plan to partition the disk during auto install or if you are using manual install, you have two choices for installing WingZ:
1. Install WingZ either in /usr/users/Wingz or /opt/Wingz before installing CWM.
2. Install WingZ either in /usr/users/Wingz or /opt/Wingz after installing CWM and then execute IntegrateWingz.
You install WingZ software from the WingZ tape or CD. Note, WingZ version 2.5 should be installed for CWM release 9.2.09. After installing, contact WingZ for a runtime license and blend it with CWM 9.2.09. Failing to do so results in the "There is a problem with the registration information for this machine. Contact your system administrator" error message when you click on the CWM Report icon.
When Informix is installed on a disk array (typically the device name is /dev/vx/rdsk/rootdg/vol03) the ownership of the device and the group ownership of the device should be set to informix. The mode of the device should be 770. Otherwise, after rebooting the machine, the "Shared memory is not initialized" error message appears on the console.
When you are installing HP/OV 5.01 over an existing version, make sure the /etc/snmpd and /etc/snmpd.conf files are removed or re-named before carrying out the upgrade. If these files are not removed or renamed, it is likely you will see the following message when trying to re-start HP/OV:
object manager name: netmonbehavior: OVs_WELL_BEHAVEDstate: NOT_RUNNINGPID: -last message: Can't talk to snmpd; see /usr/OV/log/netmon.trace forinfoexit status: exit(1)
Information left in these files causes problems for the new version of HP/OV.
These files are not removed by the ovremove program.
You can upgrade of CWM from 9.1.x to 9.2.09. The incomplete connections in the user_connection table in SV+ 9.1 may not show properly (count) on upgraded CWM 9.2.09. However, a complete user_connection table will be properly propagated to an upgraded CWM workstation.
The default CWM configuration supports most networks. Very large networks with a significant number of PVCs (100,000 or more) require a change to the default CWM configuration for better performance during cold or warm starts of CWM.
The /usr/users/svplus/config/emd.conf file provides nineteen configuration parameters that control the operation of the Equipment Manager Switch Daemon (EMSD). Each of the nineteen parameters is preceded by a comment statement that describes the parameter. To achieve better cold and warm start performance, complete the following steps:
Step 1 Search for Tftp Timeout, and change the value from 1 hour to 2 hours.
Step 2 Search for Attempt to resynchronize, then change the value from 10 times to
40 times.
Step 3 Change the next parameter, Upload TFTP file, from 4 times to 15 times.
Step 4 Search for next SNMP shelf config request, then change the value from Minimum 600 to Minimum 300 (seconds backoff).
The /usr/users/svplus/config/tftpmgr.conf file provides configuration parameters about the TFTP Request Manager. To achieve better cold and warm start performance, complete the following steps:
Step 1 Change the NumberOfRetries value to 40 from the default value of 20.
Step 2 Change the MaxTFTPSession value to 72 from the default value of 32.
CWM 9.2.09 to Cisco WAN switch (outgoing): ports used in the switch
Cisco WAN switch to CWM 9.2.09 (incoming): ports used in CWM 9.2.09
To provide unique node IDs across all CWM stations, you must copy the nodes.config file to all CWM stations. The CWM upgrade procedure creates the nodes.config file from the existing node table. This file is in the /usr/users/svplus/config directory.
Default security profiles and those created by your site's system administrator are currently stored on local CWM disks in the /usr/users/svplus/config directory. This is designed to allow you to have different profiles on various CWM stations. If you want all users to have the same security profiles across all CWM stations, you must copy the files listed below to all CWM stations. The following files must be copied manually:
1. configinfo.sm
2. defaultAdmin.sm
3. defconfiginfo.sm
4. profileInfo.sm
5. userInfo.sm
To copy the security profiles from station1 to station2, complete the following steps (as user svplus or as a user with Admin privileges):
Step 1 On station1, change directory to /usr/users/svplus/config.
Step 2 Enter the remote copy command for each file, such as:
rcp configinfo.sm station2:/usr/users/svplus/confg
Step 3 Repeat the above step for all five security profile files previously listed.
This section contains descriptions of five tables of CWM 9.2.09 database that support new VISM features or are new for CWM 9.2.09. Two of the tables (VISM_CARD and VISM_ENDPT) contain minor modifications from the 9.2.08 release. Three other tables (MG_SUP_PRTCL, MGC_RES, SRCP_PEER) support new VISM features in CWM 9.2.09.
Table 8 contains information about VISM cards managed by CWM.
| Column Name | Type | Description |
|---|---|---|
network_id | smallint | Network ID |
node_id | integer | Node ID |
shelf | integer | Shelf number |
slot | smallint | Slot number |
ipaddress | integer | vismIpAddress |
subnetmask | integer | vismSubnetMask |
mg_name | char(64) | Media Gateway name mgName |
mg_adminstate | smallint | current admin state of Media Gateway: |
mg_adminstate_ctrl | smallint | Used to control the administrative state: |
xgcp_req_timeout | integer | The request timeout is used to determine the timeout value used for retransmitting unacknowledged message xgcpRequestTimeOut (milliseconds) |
xgcp_req_retries | smallint | This object specifies the number of retries for a request that exceeds timeout xgcpRequestRetries 010 |
restart_inprogress | integer | The maximum waiting delay (MWD) timeout value is used for the Media Gateway to send the Restart In Progress to the Media Gateway Controller xgcpRestartInProgressMWD |
ecan_encoding | smallint | The voice encoding type vismEcanEncoding |
avail_ds0count | smallint | The no of DS0s available for new connections on VISMvismAvailableDs0Count |
mode | smallint | The connection model that the VISM card is configured to operate with vismMode |
cacEnable | smallint | Describes whether CAC (Connection Admission Control) functionality needs to be applied on the VISM card vismCacEnable |
ecanIdlePattern | smallint | Echo canceller pattern for Idle code vismEcanCnfIdlePattern |
ecanIdleDir | smallint | Echo canceller idle direction vismEcanCnfIdleDirection |
vismErl | smallint | Provision the return echo lost vismERL |
jitDelMode | smallint | Provision the jitter buffer mode to be applied to call connection vismJitterDelayMode |
jitInitDelay | smallint | Defines the jitter buffer size vismJitterInitialDelay |
gainCtrl | smallint | The control to adjust the gain of the call connection vismAdaptiveGainControl |
muxtype | smallint | A card-level parameter for AAL2 adaptation; it identifies the multiplexing function of the AAL2 Commom Part Sublayer. vismAal2SubcellMuxing |
reserved | integer | reserved for future use |
Table 9 contains information about VISM endpoints.
| Column Name | Type | Description |
|---|---|---|
network_id | smallint | Network ID |
node_id | integer | Node ID |
shelf | integer | Shelf number |
slot | smallint | Slot number |
endpoint | smallint | Identifies endpoint as it is known by the NE mgEndpointNumber is from 1 - 240. |
line | smallint | Identifies the line mgEndointLineNumber |
name | char(64) | Identifies endpoint as it is known by the MGC mgEndpointName |
state | smallint | Indicates the state of the endpoint: |
channel_map | integer | Positions of 1-bits indicate channels used by the endpoint mgEndpointChannelMap |
reserved | integer | reserve field |
Table 10 contains information about the VISM media gateway supported protocol table.
| Column Name | Type | Description |
|---|---|---|
network_id | smallint | Network ID |
node_id | integer | Node ID |
shelf | integer | Shelf number |
slot | smallint | Slot number |
protocol | smallint | Protocol index mgProtocolNumber |
name | char(64) | a control protocol and its revision supported by the call gateway
mgProtocolName |
reserved | integer | reserve field |
Table 11 contains information about VISM media gateway controller resolution.
| Column Name | Type | Description |
|---|---|---|
network_id | smallint | Network ID |
node_id | integer | Node ID |
shelf | integer | Shelf number |
slot | smallint | Slot number |
index | smallint | Name to IP address for each of the MGCs mgcResolutionIndex |
name | char(64) | name of the entity (MGC and/or Notified Entity) whose address is to be resolved mgcResolutionName |
ipaddr | integer | Ip address of the entity mgcResolutionIpAddress |
comm_state | smallint | Indicates whether the address is the one currently applied for communications with system of that name mgcResolutionCommState csActive - 1 |
preference | integer | Allows you to optionally configure primaries and secondaries mgcResolutionPreference |
reserved | integer | reserve field |
Table 12 contains information about VISM SRCP peer table.
| Column Name | Type | Description |
|---|---|---|
network_id | smallint | Network ID |
node_id | integer | Node ID |
shelf | integer | Shelf number |
slot | smallint | Slot number |
peerid | smallint | srcp peer Index srcpPeerId |
name | char(64) | name of the srcp peer srcpPeerName |
peerport | integer | used to configure the UDP port of the srcp peer srcpPeerPortNumber default 2048 |
hb_interval | integer | length of the heartbeat interval in milliseconds. If 0, hearbeat for this peer is not monitored srcpPeerHeartbeatInterval |
time_since_hb | integer | time since the last heartbeat was received in milliseconds srcpPeerTimeSinceHeartbeat |
max_pdu_size | integer | maximum UDP size in octets srcpPeerMaxPduSize |
reserved | integer | reserved field |
After performing the creation of a new database by executing the create_db command, if CWM is restarted before it is synchronized with the network, it will result in a database inconsistency. In this case, perform create_db before restarting CWM to avoid database inconsistencies.
The logical_connection table count for a node in the CWM database may not match the master lcon counts in that node. This happens when the database contains FastPAD connections, or when the database has slave lcons with no connections.
When a Gateway node is upgraded or rebuilt, before CWM has synchronized up with the network, CWM must be cold-started (create CWM database and restart CWM). This is required to ensure CWM database consistency.
The CWM database and network may differ by value 1 for parameters PCR(0+1), SCR(0+1), MCR, ICR of some ATM-FR connections. This happens because of the difference (rounding effect) in conversion algorithms used by CWM and the Switch to convert values in cells/second units to 100 bit/second units.
| cell/second | 100 bit/second |
|---|---|
50 | 192 |
5760 | 22119 |
3259 | 12515 |
2834 | 10883 |
| Cell/second | CWM 100 bit/second | Switch 100 bit/second |
|---|---|---|
5760 | 22119 | 22118 |
3259 | 12515 | 12514 |
2834 | 10883 | 10882 |


F1 and F2 are feeder shelves, and S1 and S2 are routing nodes. If S1 becomes unreachable after receiving an add request from CWM, but before sending the response back, Middle segment will be added on S1, between S1 and S2. However, this connection's segment details will not be in the CWM database. Once S1 becomes reachable, configuration changes will be sent to CWM and the CWM database will be updated with the middle segment details. You can delete the incomplete connection at this time, using CWM.F1 (or F2) is an MGX 8220 shelf and it becomes unreachable after receiving an add connection segment request, CWM does not get updated with the end segment details, even if the node becomes reachable. The database update happens whenever the next periodic Node Resync by CWM happens with that shelf. S1 becomes unreachable after receiving a delete request from CWM, but before sending the response back, Middle segment will be deleted on S1, between S1 and S2. However, this connection's segment details will not be deleted from the CWM database. Once S1 becomes reachable, configuration changes will be sent to CWM and the CWM database will be updated accordingly. F1 (or F2) is an MGX 8220 shelf and it becomes unreachable after receiving a delete connection segment request, CWM does not delete the end segment details from the CWM database, even if the node becomes reachable. The database update happens whenever the next periodic Node Resync by CWM happens with that shelf. Any node with IP address 192.0.0.0 or 0.0.0.0 will not be displayed or stored in CWM database. In order to configure the correct network IP address, use the cnfnwip command on the switch.
Each IPX/BPX/IGX/MGX 8220/MGX 8800 node to be managed by WAN Manager must be configured with an IP Relay IP Address (cnfnwip). The gateway node must be configured with both LAN and IP Relay IP Addresses.
The IPX/BPX routing and IPX/AF feeder nodes must be configured with read and write SNMP community names. The SNMP community names "public" and "private" are configured in CWM for GET and SET, respectively, as defaults.
The directly attached node (Gateway node) must be configured with an IP Relay IP address before starting CWM.
Node names, IP Addresses, and NWIP addresses of the nodes in a network, and across networks in multiple networks scenarios, should be uniquely configured.
Robust message updates must be enabled.
The Gateway node name must be the same as the node name specified in the config.sv file.
The maximum number of nodes that can be added through the Network Configurator is 2000. Currently, there is no error message to alert you to this situation. This is a limitation of the CWM 9.2.09 back end processes.
In the case of managing standalone MGX 8850 nodes and a tiered AutoRoute network with Automatic Discovery enabled, the addition of standalone nodes using the Network Configurator can't take place while the CWM is synchronizing with the network.
A trap will be generated when the network synchronization is done. You can activate the standalone Network Configurator by running the tool: /usr/users/svplus/bin/configurator.
For adding a connection, the connectionIndex must be 0 (for example, there is no need to do a GET on connAvailIndex). The actual index is internally generated by the Connection Service Agent itself.
In CWM 9.2.09, the Connection Template (another set of user data) is not getting propagated to other CWM workstations.
CWM 9.2.09 does not use the Service Rate parameter applicable to FRSM channels, while adding FRSM channels, using the CIR instead. If you add FRSM PVCs through the Switch CLI using Service Rate, you will be unable to display all parameters of the PVC and unable to modify the PVC.
For DAS connections, deleting an end point from a segment, and later adding it to another segment at a very fast rate, may result in a CWM database inconsistency.
Test Connection and Test Delay do not work for connections routed through a Cisco virtual trunk cloud when the connection originates from an MGX 8220 or BPX midpoint.
The Connection Manager GUI for preferred route displays all available trunks without considering the traffic class. As a result, it is possible to set a preferred route for a CBR connection traversing trunks that do not support CBR traffic.
In the Connection Manager GUI, you must enter both the end points (node, shelf, slot, port) in the Add Connection window before entering any connection or midpoint parameters.
For an FRSM - ASI PVC connection, the error message "Remote SCR value out of range", generated by the remote BPX, indicates the CIR value of the Frame Relay side is below the acceptable limit (cell rate) of the trunk, between the MGX 8220 shelf and its routing node. To correct this problem, you can increase the value of CIR. For example, if the trunk between the MGX 8220 shelf and the routing node is a BXM trunk, the CIR value should be at least 19.2 kbps (50 cell/sec).
ABR.FS connections cannot be added with default values for an ATM-FR SIW connection. The
ICR TO value must be changed.
Certain types of connections, such as VBR.1 or CBR, with policing parameters, can't be modified by CWM if the default was changed using the Switch CLI.
While adding three segment Frame Relay connections, where one routing node is IGX and another is BPX, connections must be mastered on feeders connected to BPX. Attempting to master connections on feeders attached to an IGX hub will generate an "Internal error" error message, and the connection will not be added.
Three segment voice and data connections can only be added when both routing nodes are IGXs. This is due to a switch software limitation.
While adding connections originating and terminating on the same feeder nodes, CWM will treat these connections as three segment connections and will add three segments (two on the same feeder node, one on the routing node) to realize this connection.
Switch software supports only ATFR and ATFST types of connections for UXM on a feeder node. CWM does not support ATFR or ATFST for ATM to ATM connections (from the Connection Manager GUI select Configure->New ATM-ATM connection->VBR.3), the connection type on the Switch CLI will show as ATFR for all three segments. If you select an ABR.FS connection type for an ATM to ATM connection (from the Connection Manager GUI select Configure->New ATM-TM connection->ABR.FS), the connection type on the Switch CLI will be ATFST for all three segments. For all other limitations of connection types supported for UXM on feeder nodes, refer to the Switch Software Release Notes for release 9.2.03.
ATM-FR connections with a FR end point on an IGX/IPX running 8.4.x SWSW can not be set with channel type SIW (Service InterWorking) transparent or SIW translate. This feature is not supported by IGX/IPX running 8.4.X SWSW. The connections set using the 9.2.09 Connection Manager would fail.
The default values provided by the Connection Manager GUI for the Frame Relay end point parameters Ingress/Egress ECN Threshold and DE Threshold are not the same as those provided by the Connection Service Agent.
The Connection Manager GUI uses percentage notation for both the ECN Threshold and DE Threshold. However, the Service Agent MIB uses the absolute value for those MIB variables. If the defaults were used by the GUI and Service Agent, the following values would be setup for the PVC:
| Parameter | GUI Default Values | Service Agent |
|---|---|---|
Ingress ECN Threshold | 10% of Ingress VC Q Depth -> 6554 | 6553 |
Ingress DE Threshold | 50% of Ingress VC Q Depth -> 32768 | 32767 |
Egress ECN Threshold | 10% of Egress VC Q Depth -> 6554 | 6553 |
Egress DE Threshold | 50% of Egress VC Q Depth -> 32768 | 32767 |
The switch generates the "Failure validating remote endpoint description" error message when the PVC was modified or deleted using CWM. The problem occurs when CWM is managing a mixed release network and the node mastering the PVC has an older release than the remote end, and the remote end point is in a newer card which was introduced after the older release. This is a SWSW limitation. The PVC can be deleted using the Switch CLI.
The Connection Manager doesn't check for the SVC VPI/VCI partitioning range, if the VPI value is 0 and if SVC Hi VPI and Low VPI are set to 0 on the switch. Because of this, VPI 0 can be used for provisioning. However, if you reserve only 0 for the SVC range, the Connection Manager will not block the PVC provisioning.
In CWM 9.2.04, the FRSM-VHS card supports four separate QoS queues (versus two for legacy FRSM). The selection of a QoS queue (or channel service type) on the FRSM-VHS channel has restrictions on the service type of the ATM routing segment. For a High Priority class of connection (High Priority Queue, Q1), CWM 9.2.04 will select the CBR service type for the routing segment. For VBR-rt (real-time VBR, Q2), the VBR service type is selected. For VBR-nrt (non-real time VBR, Q3), the ATFR service type is selected. For ABR-FS (Available Bit Rate, Q4) or UBR (Unspecified Bit Rate, Q4), the ATFS service type is selected.
ForeSight connections are not supported in PXM UNI ports. In other words, you are not able to create abr.fs service type connections with end points on a PXM UNI port.
Cisco WAN Manager 9.2 supports connections for Frame Relay (FR), Asynchronous Transfer Mode (ATM) both Unicast and ATM-Multicast, Circuit Emulation (CE), Voice, and Data service modules. The following connection types are supported:
Table 13 lists the types of cards supported in CWM 9.2 and the different cards in each card type.
| Card Type | Cards Supported |
|---|---|
FR | FRSM (4T1, 4E1, 8T1, 8E1, HS1b.V35), FRM, UFM |
FRQOS | FRSM (2CT3, 2E3, 2T3, HS2) |
FRASM | FRASM |
ATM | AUSM (4T1, 4E1, 8T1, 8E1), AUSMB (8T1, 8E1), PXM, ASI, ASI-155, BXM, UXM |
ATM-Multicast | BME |
CE | CESM (4T1, 4E1, 8T1, 8E1, T3, E3) |
RPM | RPM |
Voice Service Modules | CVM, UVM |
Data Service Modules | CVM, UVM, HDM, LDM |
This section lists the Frame Relay service modules, cards, and ports supported in CWM 9.2.
The following FRSM-VHS cards are supported on the MGX platforms:
Frame Relay and FRSM-VHS cards support the following types of ports:
This section lists the ATM service modules, cards, and ports supported in CWM 9.2.
The following service modules support MGX 8220 and MGX 8850:
The following cards support ATM and IM-ATM ports:
The BME card in BPX 8600 is the only card supporting multicast connections.
The RPM card is supported in MGX 8850.
This section lists the CE service modules, cards, and ports supported in CWM 9.2.
This section lists the voice service modules supported in CWM 9.2.
This section lists the data service modules supported in CWM 9.2.
This section provides a summary of supported connections in CWM 9.2
Table 14 lists the supported FR - FR connections. These connections offer a choice of either FR or FRASM port types.
| ForeSight Features | Quality of Support (QOS) | Local End Point (LEP) Card Types | Remote End Point (REP) Card Types |
|---|---|---|---|
Choice of features | None | FR, FRASM | FR, FRASM |
Enabled for QOS types UBR and ABR | Specified by ChanServType attribute on FRSM-VHS service modules: | FRQOS | FR, FRASM, FRQOS |
Table 15 lists the supported ATM - FR connections, including card types, for local end points (LEP) and remote end points (REP).
| Service Type | Port Types | ForeSight | QoS | LEP Card Types | REP Card Types | Restrictions |
|---|---|---|---|---|---|---|
nrt-vbr3, | FR or FRASM | None | No QoS support on FR end point | ATM | FR or FRASM | abr.fs not supported with ATM SM-PXM |
cbr1 | FR | Available on abr.fs only | QoS support on FR end point | ATM | FRQOS |
|
rt-vbr(2, 3) | FR | None | QoS support on FR end point | ATM | FRQOS | Real time feature should be supported by the network and ATM service module. abr.fs not supported with ATM SM-PXM. |
nrt-vbr3 | FR | None | No QoS support on FR end point | RPM | FR or FRASM |
|
nrt-vbr3 | FR | None | QoS support on FR end point | RPM | FRQOS |
|
Table 16 lists the supported ATM-ATM connections, including card types, for local end points (LEP) and remote end points (REP).
| Service Type | ForeSight | LEP Card Types | REP Card Types | Restrictions |
|---|---|---|---|---|
cbr1 | Available for abr.fs only | ATM | ATM | rt-vbr available only if both network and service modules support the rt feature. ForeSight is not supported with cbr and PXM cards. |
rt-vbr(1, 2, 3) | None | ATM | ATM | Real time feature should be supported by the network and ATM service modules. |
cbr1 | Available for abr.fs only | ATM-Multicast | ATM-Multicast | Local/remote port combinations: |
nrt-vbr3 | None | ATM or RPM | ATM or RPM |
|
Table 17 lists the remaining supported connections in CWM 9.2, including card types, for local end points (LEP) and remote end points (REP).
| Connection Type | Service Type | Additional Classification | LEP Card Types | REP Card Types | Restrictions |
|---|---|---|---|---|---|
CE - CE | cbr | Structured or unstructured | CE | CE | Both end points must be structured or unstructured, and bandwidth and interface types must also match. |
ATM - CE | cbr | CE structured or unstructured | Either | Either | ATM end point bandwidth must be equal to or greater than CE end point bandwidth. |
Data - Data | none | None | Data service module | Data service module | Connection routing path cannot include a BPX 8600. |
Voice - Voice | None | None | Voice service module | Voice service module | Connection routing path cannot include a BPX 8600. |
Cisco recommends you use the default number of three SCM children specified by CWM 9.2.09.
When you start a stand-alone SCM, the "Cannot communicate with CWM" message is not an error message; either CWM is not active or another GUI is presently running.
You should select a routing node for the SCM time sync node.
For a group of selected nodes from which statistics files are to be collected by a stand-alone SCM, the collection period should be set to the same value for all nodes.
If statistics files are being saved, the SCM does not purge these files, even if the disk is full.
The SCM supports a maximum of 3100 nodes in stand-alone mode.
Whenever you perform a create_db operation, the statshistory.stats file must be manually deleted.
The following rules are used when you configure peak interval through CWM. Violating these rules will cause TFTP error 22 to be displayed in the SCM.
The switch needs some processing time to parse the stats.enable file. Depending on the number of statistics and the number of objects, this time can be very large. Currently, SCM has a finite value for time-out (maximum 420 seconds) to wait for the switch response. Hence, there might be cases where SCM will time-out waiting for the switch to finish parsing the stats.enable file. If there are excessive time-outs, try one of the following:
1. Cut down on the number of statistics enabled and be able to get the status of stats-enabling from SCM.
2. Keep the number of statistics, however, lose the status of stats-enabling from the SCM.
You can use CLI commands such as dspstatparms, dspchstatcnf, dsptrkstatcnf, dspportstatcnf, and dsplnstatcnf to make sure their desired stats are enabled. Note, there can be occasional time-outs if a node is busy for that period of time, however, this case, at best, is intermittent and should go away once loading on the node stabilizes. Following is the formula to calculate the time to enable statistics on the switch:
time = (stats / cnt) * delay
where
stats = (conns * stats_per_con) +
(CLNs * stats_per_cln) +
(trks * stats_per_trk) +
(ports * stats_per_port)
cnt = number of stats configured in one group before giving up CPU, a configurable parameter on the switch.
delay = a delay time between each group of stats get enabled, this is also a configurable parameter on switch.
This information is captured in CR CSCdj39737.
While CWM is running, if the X server crashes for any reason, CWM should be stopped and restarted.
While CWM is running, if the remote display is killed without properly shutting down the CWM Desktop, then reopening it remotely may not succeed.
CWM must be started from a CDE environment.
The WingZ "Add Comment" option is not supported for virtual trunk and ATM connections. WingZ occasionally does not scroll up the list box properly.
It may occasionally take two to three minutes to display new nodes after the addition of virtual trunks. This is due to the time required to setup link0 and link1 subscriptions.
Always use the CWM ImageDownload program to do a SW/FW download. As CWM does not make any assumptions on the filename, it requires you to tell the SW the filename and the path to download, avoiding any inconsistencies resulting from the file naming assumptions made by the getfwrev and loadfwrev commands. If the CWM ImageDownload program does not work, there is a problem with the file transfer or the image.
CWM 9.2.09 supports only ATM connection type and vbr.3 service type for end points terminated on the RPM card.
For an RPM VCCON, the only VPI value allowed is 0. To add an RPM VPCON, an asterisk (*) should be specified as the VCI value.
If a VPI, VCI value is used to establish an RPM channel on one subinterface, the SAME VPI, VCI pair cannot be used with another subinterface. This is due to an RPM limitation. If such action is attempted, CWM 9.2.09 will emit an "Local/Remote end point already exists" error.
CWM 9.2.09 does not support provisioning of RPM channels for subinterface values over 32767.
For a PVC involving RPM, CWM 9.2.09 supports ATM Service Type VBR only (VBR.3 for ATM-ATM and ATM-FR for ATM to FR PVCs). The UBR Service Type is not supported for RPM by CWM 9.2.09.
CWM 9.2.09 provisions the RPM end of an "End to End" PVC by using the IOS atm pvc command followed by the addcon command. An RPM end point added using the atm pvc command cannot be modified/deleted using the (newer) pvc add command and vice-versa.
To establish a channel on RPM, two IOS commands are required:
1. atm pvcto add the RPM "leg" of the channel.
2. addconto add the PXM "leg" of the channel.
If the RPM leg gets deleted (new configuration restored on RPM), CWM 9.2.09 cannot detect the condition. However, if necessary, CWM 9.2.09 can be used to delete and re-add the entire channel by reprovisioning the "End to End" PVC.
If the PXM leg gets deleted (for example, clrallcn on MGX 8850), CWM 9.2.09 cannot provision the channel until the RPM leg is manually deleted. To do that, you must login to the RPM card and perform the following IOS commands:
1. no atm pvcto delete the RPM "leg" of the channel.
2. no addconto delete the PXM "leg" of the channel.
The peak and average values for a feeder PVC involving RPM is limited by the bandwidth of the MGX 8850 feeder trunk. As per the strata MIB, the value of average (expressed in cells/second below) is limited for each trunk type as:
ASI/BNI
T3: 0-96000
E3: 0-80000
OC3: 0-353208
BXM/UXM
T3: 6-96000
E3: 6-80000
OC3: 6-353208
OC12: 6-1412832
ALM-B(BTM)
T3/E3: 10-24000
The value of peak (express here in cells/second) is limited as for each trunk type as:
T3: average-96000
E3: average-80000
OC3: average-353208
OC12: average-1412832
BXM with HEC line formatting
T3_HEC: average-104268
While one CWM 9.2.09 station is used to provision connections on a specific RPM card, attempts to provision on the same card by another CWM 9.2.09 station can result in failure in the provisioning of RPM connections.
Provisioning of RPM can take up to 25 seconds on average. On rare occasions, the Connection Manager GUI may time out before IOSMGR returns. The returned IOS messages are eventually updated in the Result pane in the Connection Manager GUI.
The following are the typical causes of the error message "atm pvc missing":
The typical cause of the error "add connection to PXM failed" is the resource partition is not configured.
If one of the following error message is encountered:
Complete the following steps:
Step 1 telnet to the MGX 8850 and login to the RPM card (in enable mode).
Step 2 Enter the command show log and hit Return to go to the end.
For other error messages returned by IOSMGR, complete the following steps:
Step 1 vi ~svplus/log/iosmgr.log
Step 2 Go to the end of the file ($G) and check the command and arguments used for the expect script. Check the tracefile entry as shown at the end of the command.
Step 3 Open the tracefile file and go to the end of the file. Examine the log of the expect session.
The existing RPM connections will not be removed from the CWM database when the RPM card is pulled out of the MGX 8850 shelf.
Cisco WAN Manager 9.2.09 and Cisco Works 2000 can co-exist on the same CWM workstation provided there is sufficient disk space to support both applications. Both applications provide full functionality except for a limitation with the Connection Manager GUI when both applications are running simultaneously.
When both applications are running simultaneously, a performance degradation occurs during synchronization. The time it takes to synchronize may take from 25% to 30% longer.
Cisco recommends that you use a midrange to high-end platform workstation when you intend to use Cisco Works 2000 with CWM.
| Component | Requirement |
|---|---|
Workstation | Sun Ultra 60 with two CPUs |
Memory | 1 MB RAM |
Disk space | Two 9-GB SCSI disks |
Table 19 lists the partitioning for disk 1. Table 20 lists the partitioning for disk 2.
| File System | Slice | Flag | Size | Mount Point |
|---|---|---|---|---|
root | 0 | sm | 1 GB | / |
swap | 1 | wu | 1 GB | /tmp |
backup | 2 | wm | 8.43 | (total disk) |
var | 4 | wm | 2.5 GB | /var |
usr | 6 | wm | 1.95 GB | /usr/users |
unassigned | 7 | wm | 1.95 | /tmp |
| File System | Slice | Flag | Size | Mount Point |
|---|---|---|---|---|
backup | 2 | wm | 8.43 | (total disk) |
unassigned | 3 | wm | 5.86 GB | /opt |
Install Cisco WAN Manager in the usual way. After installing CWM, install Cisco Works 2000. Install the Cisco Works packages in the following order:
1. CD One (DMS)
2. Resource Manager (RME)
3. Campus Manager (CM)
When using CWM and Cisco Works 2000 on a single CWM workstation simultaneously, the following limiting condition occurs. The Connection Manager GUI blanks out when gathering node information or searching connection end points for a node with 5,000 or more connections and does not refresh. This condition does not occur if Cisco Works 2000 is not running.
To work around this limitation, you must limit the scope of the search by reducing the search criteria in connection end points to the node name and port. Otherwise, you will have to kill the Connection Manager GUI process and restart it by once again launching the Connection Manager.
The SNMP master agent is configured to use 8161 as a default port ID for agent communication. The SNMPAgent.conf configuration file for the master agent is located in the /usr/users/svplus/config directory. If you are running another Network Manager which uses port number 8161, this UDP port can be configured to some other port number in the SNMPAgent.conf file as follows:
The Service MIB (Connection Service MIB and Port Service MIB) uses community strings for authentication. The Connection Service Agent and Port Service Agent processes use the /usr/users/svplus/config/SNMPProxy.conf file as a configuration file. The SNMP community name strings can be configured in this file as follows:
The SNMP community names public and private are configured in this file for GET and SET respectively, as defaults.
For MGX 8220, this CiscoView Package requires MGX 8220 Boot Code version 4.0.x and MGX 8220 ASC firmware version 4.0.x or higher. For the new features, MGX 8220 firmware 4.0.15d or later is recommended.
In addition to the Installation instructions, please refer to the README.txt file.
Before selecting a device, use the "Options-.Properties" menu to configure the Polling Frequency, Retries, Timeout, and Monitor Frequency. The recommended Polling Frequency is at least 60 seconds, otherwise the performance of Cisco View may be noticeably degraded. The recommended timeout value is 15 seconds and the recommended monitor frequency is 60 seconds.
When upgrading MSSBU device packages, use "uninstallpkg" to remove all older versions of those packages before installing new ones. This helps to avoid any compatibility problems with different versions of device packages that might share common files.
When installing with Cisco WAN Manager, please verify that all the desired devices have been successfully installed with the "help about Ciscoview packages installed" utility. If a particular device package is missing, it can be installed with the "cvinstall" command.
You must install the CiscoView engine CD first, then install the CWM 9.2.09 CD. In the CWM 9.2.09 installation process, the WANCV 2.09 device packages will be installed automatically.
If CiscoView is already installed, you may install additional device packages or upgrade them with the /opt/CSCOcv/bin/cvinstall command. When upgrading packages, an old package may need to be removed with the uninstallpkg command before installing the new one. A good practice is to use the same revision of all WANCV device packages, and to uninstall all the previous revisions first. The installation of CWM 9.2.09 will do this automatically if CiscoView is installed before CWM.
Following are examples to install WANCV device packages:
For general CiscoView information including installation, see:
http://www.cisco.com/univ-src/ccden/data/doc/cview.htm
| Caution A "timeout" or "too big" error response for an SNMP get-request may produce undesired results with CiscoView 4.1 or the initial release of CiscoView 4.2. |
Use of CiscoView 4.2 with Software Module Updates (SMU) available from CCO is recommended.
Following is a typical SMU installation example (CiscoView on Solaris, using C shell):
host% su root
host# cd /var/tmp
host# mkdir nmpath; cd nmpath
host# ftp 192.31.7.130
host# uncompress cview-01-sol-hpov-cv42.tar.Z
host# tar -xvf cview-01-sol-hpov-cv42.tar
host# source $NMSROOT/etc/install.cshrc
host# ./install-smu
The various timers and retry counter should be configured from the Options->Properties menu. For a typical installation, Polling and Monitoring should be about 60 seconds and Timeout should be at least 15 seconds. Faster polling and monitoring values can be configured if conditions permit.
Each BPX 8600, IGX 8400, MGX 8220, or MGX 8800 node to be managed by Cisco WAN Manager must be configured with an IP Relay IP address (cnfnwip). The Gateway node must be configured with both LAN and IP Relay IP addresses.
The BPX routing and AF feeder nodes must be configured with read and write SNMP community names. The SNMP community names public and private are configured in CWM for GET and SET respectively, as defaults.
The directly attached node (Gateway node) must be configured with an IP Relay IP address before starting CWM.
Node names, IP addresses, and NWIP addresses of the nodes in a network, and across networks in multiple networks scenarios, should be uniquely configured.
The following interface changes are new in CWM 9.2.09.
A new enumeration ima-feeder-trunk has been added to the trapTrunkType object.
The following new objects were added:
Enumeration changes:
Descriptions were updated for the following objects:
Miscellaneous:
A new sequence entry frEndPointChanServRate was added to the frEndPointEntry object.
The following objects were added:
Enumeration changes:
The following range changes were made:
Descriptions were updated for the following objects:
Miscellaneous:
This section provides information about changes in the CWM database for the 9.2.04 release of CWM from the 9.1 release.
Table 21 lists changes to the CWM database definitions from 9.2.04 to 9.2.05. The CWM 9.2.05 upgrade script and CreateDB script were updated to support these changes.
Table Name | Column Name | Data Type | Description |
|---|---|---|---|
card | egr_qos_feature | short | Egress Queue feature. |
connection | service_rate | integer | Channel service rate. |
Table 22 lists changes to the CWM database definitions from 9.2.03 to 9.2.04. The CWM 9.2.04 upgrade script and CreateDB script were updated to support these changes.
Table Name | Column Name | Data Type | Description |
|---|---|---|---|
atm_connection | vp_flag | short | Indicates a VP connection |
user_connection | l_vp_flag | short | Indicates a local VP connection |
user_connection | r_vp_flag | short | Indicates a remote VP connection |
dbkr_temp | l_vp_flag | short | Indicates a local VP connection |
dbkr_temp | r_vp_flag | short | Indicates a remote VP connection |
rpm_connection | vp_flag | short | Indicates a VP connection |
Table 23 lists new tables in the CWM 9.2.05 database that were not in releases prior to CWM 9.2.05.
Table Name | Description |
|---|---|
CARD | Contains information about AXIS Cards (For CWM version 8.1 or later). It also contains information of IPX/BPX/IGX cards (CWM version 8.4 or later). |
LINE | Contains information about AXIS Lines (CWM version 8.1 or later). |
PLCP | Contains information about AXIS PLCPs (CWM version 8.1 or later). |
AUSM_PORT | Contains information about AUSM ports (CWM version 8.2 or later). |
AUSM_PORT_DATA | Contains information about AUSM port statistics (CWM version 8.2 or later). |
CESM_CONNECTION | Contains information about CESM connections (CWM version 8.2 or later; AXIS only). |
DNS_NODE | Contains information about DNS nodes (CWM version 8.2 or later). |
REDUNDANT_CARD | Contains information about redundant cards (CWM version 8.4 or later; AXIS only). |
LINE_DISTRIBUTION | Contains information about line distribution (CWM version 8.4 or later; AXIS only). |
VP_RANGE | Contains information about VP range (CWM version 8.4 or later; AXIS only). |
VOICE_CHANNEL | Contains information about the voice channel (CWM version 9.0 or later). |
DATA_CHANNEL | Contains information about the data channel (CWM version 9.0 or later). |
RPM_CONNECTION | Contains information about RPM connections. |
RSC_PART | Contains information about. |
RPM_PORT | Contains information about RPM ports. |
PHY_LINE | Contains information about physical lines. |
PHY_LN_DATA | Contains physical line statistics data. |
Table 24 lists new fields in the CWM 9.2.05 database (and some recent versions of StrataView Plus) that were not in releases prior to CWM 9.2.0.
Table Name | Column Name | Unique Identifier Field | Data Type | Description |
|---|---|---|---|---|
SY_SYSTEM | name | yes | char (8+1) | Name of the CWM parameter |
SY_VERSION | release | yes | char (20+1) | CWM release number. |
SY_VERSION | release_date |
| char (32+1) | CWM release date. |
NETWORK | netw_id | yes | short | CWM network ID. |
NETWORK | netw_name |
| char (8+1) | CWM network name. |
NETWORK | mgmt_comm |
| smallint | 0 = NWIP_OFF 1 = NWIP_ON 2 = NWIP_OFF -1 = default value |
NODE | platform |
| short | 14 = MGX |
NODE | mgmt_state |
| short | Node management state. 0 = Link unknown 1 = Link up 2 = Link Down |
NODE | manager |
| smallint | Default value = 0 |
PACKET_LINE | l_num_phy_line |
| short | Default value for upgrade to SV+ 9.2 is -1 |
PACKET_LINE | l_primary_phy_line |
| smallint | Local-end primary physical line ID. |
PACKET_LINE | l_phy_line_bitmap |
| smallint | Local-end physical line bitmap. |
PACKET_LINE | r_num_phy_line |
| short | Default value for upgrade to CWM 9.2 is -1. |
PACKET_LINE | r_phy_line_bitmap |
| smallint | Remote-end physical line bitmap. |
PACKET_LINE | r_primary_phy_line |
| smallint | Remote-end primary physical line ID. |
PACKET_LINE | aps_flag |
| smallint | Default value is 0. |
PACKET_LINE | max_chan_per_port |
| integer | Default value is = -1 |
FRP | l_network_id |
| short | CWM network ID. |
FRP | l_node_id | yes | int | CWM node ID. |
FRP | l_network_id |
| short | CWM network ID. |
FRP | l_node_id | yes | int | CWM node ID. |
FRP | elmi |
| short | Beginning with CWM version 9.1, it is also used for IGX. |
USER CONNECTION | l_node_id | Yes | int | Local-end CWM node ID. |
USER CONNECTION | termination |
| short | Type of local and remote end-points: 0 = Local end is terminated 1 = Local end is not terminated Bit 1: 0 = Remote end is terminated 1 = Remote end is not terminated Bit (2-4) - RPM |
USER CONNECTION | l_port | Yes | short | Refer to the AXIS MIBs or switch software interface document for valid ranges of these fields. Also, depending on number of segments, the meaning of this field changes, making it difficult to specify ranges which are valid for all cards. |
USER CONNECTION | l_logical_port |
| smallint | MGX 8850 RPM endpoints. Logical port number (FRSM, AUSM, CESM, FRASM). 1 = RPM Default value is -1. |
USER CONNECTION | lc_node_id |
| int | Local hub CWM node ID. |
USER CONNECTION | rc_node_id |
| int | Remote hub CWM node ID. (Same as remote node ID for connections originating in a routing node.) |
USER CONNECTION | r_logical_port |
| smallint | Default value is -1. |
USER CONNECTION | con_type |
| short | Connection type: |
USER CONNECTION | sub_type |
| short | Service type: |
USER CONNECTION | inseg_tbl_1 |
| smallint | 0 = First segment not received |
USER CONNECTION | inseg_tbl_2 |
| short | 1 = Segment already received |
USER CONNECTION | inseg_tbl_3 |
| short | 1 = Third segment received |
USER CONNECTION | l_network_id |
| short | Local-end CWM network ID. |
USER CONNECTION | l_node_id | Yes | int | Local-end CWM node ID. |
CONNECTION | r_network_id |
| short | Remote-end CWM network ID. |
CONNECTION | r_node_id |
| int | Remote-end CWM node ID. |
CONNECTION | status |
| short | Connection status: |
CONNECTION | par_subtype |
| short | Default value is -1. |
CONNECTION | par_rout_pri |
| short | Default value is -1. |
CONNECTION | par_max_cost |
| short | Default value is -1. |
CONNECTION | par_res_trk_typ |
| short | Default value is -1. |
CONNECTION | par_chan_pcr |
| int | Default value is -1. |
CONNECTION | par_chan_mcr |
| int | Default value is -1. |
CONNECTION | qbin_num |
| short | Default value is -1. |
STAT_ENABLE | l_node_id | yes | int | CWM node ID. |
STAT_ENABLE | owner_netw_id |
| short | IPX network ID of node to which CWM is connected. |
STAT_ENABLE | owner_node_id |
| short | IPX node ID to which CWM is connected. |
STAT_ENABLE | retain_period |
| int | The duration period in minutes of the records saved in the CWM database. |
PACKET_LN_DATA | l_node_id | yes | int | CWM node ID. |
CIRCUIT_LN_DATA | l_node_id | yes | int | CWM node ID. |
FRP_DATA | l_node_id | yes | int | CWM node ID. |
CONNECTION_DATA | l_node_id | yes | int | CWM node ID. |
SERIAL_LN_DATA | l_node_id | yes | int | CWM node ID. |
LOGICAL_CONN | src_node_id | yes | int | Source CWM node ID in the routes. |
LOGICAL_CONN | dst_node_id |
| int | Destination CWM node ID in the local routes. |
LOGICAL_CONN | j_dst_node_id |
| int | Destination CWM node in the junction route. |
ATM_CONNECTION | r_network_id |
| short | Remote CWM network ID. |
ATM_CONNECTION | r_node_id |
| int | Remote CWM node ID. |
ATM_CONNECTION | status |
| short | Connection status field: |
ATM_CONNECTION | par_subtype |
| short | Default value is -1. |
ATM_CONNECTION | par_rout_pri |
| short | Default value is -1. |
ATM_CONNECTION | par_max_cost |
| short | Default value is -1. |
ATM_CONNECTION | par_res_trk_typ |
| short | Default value is -1. |
ATM_CONNECTION | par_chan_pcr |
| int | Default value is -1. |
ATM_CONNECTION | par_chan_mcr |
| int | Default value is -1. |
ASI_LINE | l_network_id | queue | short | CWM network ID. |
ASI_LINE | l_node_id | Yes | int | CWM node ID. |
ASI_LINE | card_type |
| short | 41 = UXM (SV+ 9.1) |
ASI_LINE | l_trk |
| short | Logical Trunk number for trunks having physical lines. For non physical lines it is -1. Default value for upgrade to CWM 9.2 is -1. |
ASI_LINE | l_vtrk |
| short | When trunks have physical lines and it is a virtual trunk, it contains the virtual trunk number, otherwise it is -1. Default value for upgrade to CWM 9.2 is -1. |
ASI_LINE | l_line |
| short | Physical line number. This is unique per card. For example, when physical lines are 2, 3 for one trunk and 6, 7 for another trunk on the same card, this field is 2, 3 for the first trunk and 6, 7 for the second trunk. For non physical lines it is -1. Default value for upgrade to CWM 9.2 is -1. |
ASI_LINE | aps_flag |
| short | Reserved for future use. Default value is -1. |
ASI_PORT | l_network_id |
| short | CWM Network ID. |
ASI_PORT | l_node_id | yes | int | Local CWM node ID. |
FPD_CONNECTION | l_network_id |
| short | Local CWM network ID. |
FPD_CONNECTION | l_node_id | yes | int | Local CWM node ID. |
FPD_CONNECTION | r_network_id |
| short | Remote CWM network ID. |
FPD_CONNECTION | r_node_id |
| int | Remote CWM node ID. |
FTC_PORT | l_network_id |
| short | Local CWM network ID. |
FTC_PORT | l_node_id | yes | int | Local CWM node ID. |
FPD_NODE | network_id |
| short | CWM network ID. |
FPD_NODE | node_id | yes | int | CWM node ID. |
FPD_CONN_DATA | l_node_id | yes | int | Local CWM node ID. |
ASI_LN_DATA | l_node_id | yes | int | Local CWM node ID. |
ASI_PORT_DATA | l_node_id | yes | int | Local CWM node ID. |
FTC_PORT_DATA | l_node_id | yes | int | Local CWM node ID. |
BIS_OBJECT | active |
| short | BIS object active state. |
BIS_OBJECT | model |
| integer | 8410 = IGX 8 |
SHELF | node_id | yes | int | CWM node ID of the AXIS node. |
SHELF | network_id |
| short | CWM network ID. |
PERIPHERAL | obj_id |
| int | CWM Object ID of the AXIS node. |
PERIPHERAL | node_id | yes | int | CWM node ID of the AXIS node. |
PERIPHERAL | network_id |
| short | CWM network ID. |
PERIPHERAL | node_type |
| short | CWM node type. |
CARD | obj_id |
| int | CWM Object ID of the AXIS node. |
CARD | node_id | yes | int | CWM node ID of the AXIS node. |
CARD | network_id |
| short | CWM network ID. |
CARD | node_type |
| short | CWM node type. |
CARD | fc_type |
| short | New Front card type: |
CARD | fc_serial_num |
| char (12) | Front card serial number. |
CARD | fc_state |
| int | Front card state: Unititialized (0) |
CARD | bc_serial_num |
| char (12) | Back card serial number. |
CARD | sec_bc_type |
| smallint | Default value is -1. |
CARD | sec_bc_dscrp |
| char (21) | Default value is -1. |
CARD | sec_bc_serial_num |
| char (12) | Default value is -1. |
CARD | sec_bc_hw_rev |
| char (6) | Default value is -1. |
CARD | sec_bc_fw_rev |
| char (21) | Default value is -1. |
CARD | sec_bc_state |
| smallint | Default value is -1. |
CARD | rate_up |
| int | Rate up (FRSM/AUSM only). |
CARD | aps_info |
| short | Default value is -1. |
CARD | ml_chan_state |
| smallint | Multi-level channel statistics. |
LINE | node_id | yes | int | CWM node ID of the AXIS. |
LINE | network_id |
| short | CWM network ID. |
LINE | stat_alarm_state |
| int | Statistical Alarm state (currently unused in CWM). |
PLCP | node_id | yes | int | CWM node ID of the AXIS. |
PLCP | network_id |
| short | CWM network ID. |
AUSM_PORT | ausmp_obj_id | yes | int | CWM Object ID of the AXIS. |
AUSM_PORT | l_node_id | yes | int | CWM local node ID. |
AUSM_PORT | ilmi_enable |
| short | Default value is -1. |
AUSM_PORT | ima_symmetry |
| short | Default value is -1. |
AUSM_PORT | bbif_vpi_low |
| int | The lower limit of VPI range to be reserved for this logical interface. |
AUSM_PORT | bbif_vpi_high |
| int | The upper limit of VPI range to be reserved for this logical interface. |
AUSM_PORT | min_rx_links |
| short | Default value is -1. |
AUSM_PORT | min_tx_links |
| short | Default value is -1. |
AUSM_PORT | reserved |
| int | Reserved for future use. |
AUSM_PORT_DATA | l_node_id | yes | int | Local CWM node ID. |
CESM_CONNECTION | l_network_id |
| short | Local CWM network ID. |
CESM_CONNECTION | l_node_id | Yes | int | Local CWM node ID for IPX or AXIS. |
CESM_CONNECTION | r_network_id |
| short | Remote CWM network ID. |
CESM_CONNECTION | r_node_id |
| int | Remote CWM node ID. |
CESM_CONNECTION | status |
| short | Connection status field: |
CESM_CONNECTION | par_subtype |
| short | Default value is -1. |
CESM_CONNECTION | par_rout_pri |
| short | Default value is -1. |
CESM_CONNECTION | par_max_cost |
| short | Default value is -1. |
CESM_CONNECTION | par_res_trk_typ |
| short | Default value is -1. |
CESM_CONNECTION | par_chan_pcr |
| int | Default value is -1. |
CESM_CONNECTION | par_chan_mcr |
| int | Default value is -1. |
CESM_CONNECTION | par_chan_per_util |
| short | Default value is -1. |
CESM_CONNECTION | lcn |
| int | Default value is -1. |
DNS_NODE | node_id | Yes | int | CWM node ID of DNS node. |
REDUNDANT_CARD | network_id |
| short | CWM network ID. |
REDUNDANT_CARD | node_id | Yes | int | CWM node ID. |
LINE_DISTRIBUTION | network_id |
| short | CWM network ID. |
LINE_DISTRIBUTION | node_id | Yes | int | CWM node ID. |
VP_RANGE | network_id |
| short | CWM network ID. |
VP_RANGE | node_id | Yes | int | CWM node ID. |
VOICE_CHANNEL | l_node_id | Yes | int | CWM node ID. |
DATA_CHANNEL | l_node_id | yes | int | CWM node ID. |
ACCESS_NODE | node_id | yes | int | CWM node ID. |
PROTOCOL_GROUP | node_id | Yes | int | CWM node ID. |
LINK_STATION | node_id | Yes | int | CWM node ID. |
LINK_STATION | state |
| short | Operational status: |
CHANNEL_ROUTE | node_id | Yes | int | CWM node ID. |
RPM_CONNECTION | con_obj_id |
| integer |
|
RPM_CONNECTION | master_flag |
| short |
|
RPM_CONNECTION | l_network_id |
| short |
|
RPM_CONNECTION | l_node_id |
| integer |
|
RPM_CONNECTION | l_slot |
| short |
|
RPM_CONNECTION | l_line |
| short |
|
RPM_CONNECTION | l_port |
| short |
|
RPM_CONNECTION | l_vpi |
| short |
|
RPM_CONNECTION | l_vci |
| integer |
|
RPM_CONNECTION | r_network_id |
| short |
|
RPM_CONNECTION | r_node_id |
| integer |
|
RPM_CONNECTION | r_slot |
| short |
|
RPM_CONNECTION | r_line |
| short |
|
RPM_CONNECTION | r_port |
| short |
|
RPM_CONNECTION | r_vpi |
| short |
|
RPM_CONNECTION | r_vci |
| integer |
|
RPM_CONNECTION | sub_type |
| short |
|
RPM_CONNECTION | status |
| short |
|
RPM_CONNECTION | peak |
| integer |
|
RPM_CONNECTION | average |
| integer |
|
RPM_CONNECTION | burst |
| integer |
|
RPM_CONNECTION | mid_low |
| short |
|
RPM_CONNECTION | mid_high |
| short |
|
RPM_CONNECTION | oam |
| short |
|
RPM_CONNECTION | inverse_arp |
| short |
|
RPM_CONNECTION | aal_encap |
| short |
|
RPM_CONNECTION | vcd |
| integer |
|
RPM_CONNECTION | commentc |
| char (20) |
|
RSC_PART | obj_id |
| integer | Assigned by emc F (slot, port, ctrlr_type) |
RSC_PART | network_id |
| smallint | Assigned by emc |
RSC_PART | node_id |
| integer | Assigned by emc |
RSC_PART | slot |
| smallint | Assigned by emc |
RSC_PART | line |
| smallint | Line number associated with the logical interface. for PXM, four physical lines (currently) |
RSC_PART | port |
| integer | Logical interface number for RPM; value is -1 |
RSC_PART | ctrlr_type |
| smallint | Index for controller using the interface: |
RSC_PART | ingr_pctbw |
| integer | Percentage of logical interface bandwidth available for UNI channels (bbIfIngrPctBandwidth) |
RSC_PART | egr_pctbw |
| integer | Percentage of aggregate physical line bandwidth available for this broadband interface - Egress. |
RSC_PART | vpi_low |
| integer | Beginning of the VPI range reserved for this partition |
RSC_PART | vpi_high |
| integer | End of the VPI range reserved for this partition |
RSC_PART | vci_low |
| integer | Beginning of the VCI range reserved for this partition; only valid for logical interfaces configured with a single VPI |
RSC_PART | vci_high |
| integer | End of the VCI range reserved for this partition; only valid for logical interfaces configured with a single VPI |
RSC_PART | max_chans |
| integer |
|
RPM_PORT | port_obj_id |
| integer | Port Object ID |
RPM_PORT | l_network_id |
| short | Network ID |
RPM_PORT | l_node_id |
| integer | Node ID |
RPM_PORT | l_slot |
| short | rpmPortSlotNumber (1 - 30) |
RPM_PORT | l_line |
| short | One ATM interface, value currently is 1 |
RPM_PORT | l_port |
| short | rpmPortSubInterface (0 - 255) |
RPM_PORT | ip_address |
| integer | rpmPortIpAddress: IP address of the subinterface |
RPM_PORT | subnet_mask |
| integer | rpmPortSubNetMask: Subnet mask of the subinterface |
RPM_PORT | status |
| short | 1 = clear |
RPM_PORT | commentc |
| char (20) | Comment field |
PHY_LINE | phyline_obj_id |
| integer | Object ID |
PHY_LINE | l_network_id |
| short | Network ID |
PHY_LINE | l_node_id |
| integer | Node ID of integer |
PHY_LINE | card_type |
| short | 41 = UXM (SV+ 9.1) |
PHY_LINE | l_trk |
| short | Logical Trunk number for trunks having physical lines. For non physical lines it is -1. Default value for upgrade to CWM 9.2 is -1. |
PHY_LINE | l_vtrk |
| short | When trunks have physical lines and it is a virtual trunk, it contains the virtual trunk number, otherwise it is -1. Default value for upgrade to CWM 9.2 is -1. |
PHY_LINE | l_line |
| short | Physical line number. This is unique per card. For example, when physical lines are 2, 3 for one trunk and 6, 7 for another trunk on the same card, this field is 2, 3 for the first trunk and 6, 7 for the second trunk. For non physical lines it is -1. Default value for upgrade to CWM 9.2 is -1. |
PHY_LINE | primary_phy_line |
| short | Primary physical line number. |
PHY_LINE | aps_flag |
| short | Auto-protection switch flag. |
This section provides a listing of the VISM database tables that are new to the database structure in the 9.2.09 release of CWM.
| Column Name | Data Type | Description |
|---|---|---|
network_id | smallint | Network ID |
node_id | integer | Node ID |
shelf | integer | Shelf number |
slot | smallint | Slot number |
port | smallint | port number vismPortNum |
reserved | integer | reserve field |
| Column Name | Data Type | Description |
|---|---|---|
network_id | smallint | Network ID |
node_id | integer | Node ID |
shelf | integer | Shelf number |
slot | smallint | Slot number |
ipaddress | integer | vismIpAddress |
subnetmask | integer | vismSubnetMask |
mg_name | char(64) | Media Gateway name mgName |
mg_adminstate | smallint | current admin state of Media Gateway: |
mg_adminstate_ctrl | smallint | Used to control the administrative state: |
xgcp_req_timeout | integer | The request timeout is used to determine the timeout value used for retransmitting unacknowledged message xgcpRequestTimeOut (milliseconds). |
xgcp_req_retries | smallint | This object specifies the number of retries for a request that exceeds timeout xgcpRequestRetries (010). |
restart_inprogress | integer | The maximum waiting delay(MWD) timeout value is used for the Media Gateway to send the Restart In Progress to the Media Gateway Controller; xgcpRestartInProgressMWD |
ecan_encoding | smallint | The voice encoding type vismEcanEncoding |
avail_ds0count | smallint | The no of DS0s available for new connections on VISM vismAvailableDs0Count |
mode | smallint | The connection model that the VISM card is configured to operate with vismMode |
cacEnable | smallint | Describes whether CAC (Connection Admission Control) functionality needs to be applied on the VISM card: vismCacEnable |
ecanIdlePattern | smallint | Echo canceller pattern for Idle code: vismEcanCnfIdlePattern |
ecanIdleDir | smallint | Echo canceller idle direction: vismEcanCnfIdleDirection |
vismErl | smallint | Provision the return echo lost: vismERL |
jitDelMode | smallint | Provision the jitter buffer mode to be applied to call connection: vismJitterDelayMode |
jitInitDelay | smallint | Defines the jitter buffer size: vismJitterInitialDelay |
gainCtrl | smallint | The control to adjust the gain of the call connection: vismAdaptiveGainControl |
reserved | integer | reserve field |
| Column Name | Data Type | Description |
|---|---|---|
network_id | smallint | Network ID |
node_id | integer | Node ID |
shelf | integer | Shelf number |
slot | smallint | Slot number |
endpoint | smallint | Identifies endpoint as it is known by the NE mgEndpointNumber 1240 |
line | smallint | Identifies the line mgEndointLineNumber |
name | char(64) | Identifies endpoint as it is known by the MGC mgEndpointName |
state | smallint | Indicates the state of the endpoint: |
channel_map | integer | Positions of 1-bits indicate channels used by the endpoint mgEndpointChannelMap |
reserved | integer | reserve field |
| Column Name | Data Type | Description |
|---|---|---|
network_id | smallint | Network ID |
node_id | integer | Node ID |
shelf | integer | Shelf number |
slot | smallint | Slot number |
controller | smallint | Individual media gateway controller index (mgcNumber) |
name | char(64) | name of the media gateway controller (mgcName) |
assoc_state | smallint | state of the association between the Media Gateway and the Media Gateway Controller: |
assoc_state_ctrl | smallint | control the association state, as represented by mgcAssociationState mgcAssociationStateControl mgcUnassociate - 1 mgcAssociate - 2 |
reserved | integer | reserve field |
| Column Name | Data Type | Description |
|---|---|---|
network_id | smallint | Network ID |
node_id | integer | Node ID |
shelf | integer | Shelf number |
slot | smallint | Slot number |
controller | smallint | media gateway controller number mgcNumber |
protocol | smallint | references the protocol, reflecting the mgProtocolNumber from the mgSupported table mgProtocolNumber |
reserved | integer | reserve field |
| Column Name | Data Type | Description |
|---|---|---|
chnl_obj_id | integer | Voice channel object ID |
l_node_id | integer | CWM node ID |
1_slot | smallint | slot number |
l_line | smallint | port number |
l_chnl | smallint | channel number |
per_util | smallint | percent utilization (0 - 100) |
cos | smallint | class of service |
eia | smallint | EIA rate (0 - 20) |
dfm_len | smallint | DFM length (0, 1, 7, 8, 16) |
chnl_info | smallint | data channel info: |
input_loss | smallint | input loss |
output_loss | smallint | output loss |
onhook_ab | smallint | Onhook AB: Bit7-5: Onhook A: 0=0, 1=1, 2=don't care, 3=unknown, 4=notUsed Bit4-2: Onhook B: 0=0, 1=1, 2=don't care, 3=unknown, 4=notUsed Bit1-0: Dial type: 0=Inband, 1 = pulse, 2=User Dial |
onhook_cd | smallint | Onhook CD: Bit7-5: Onhook C: 0=0, 1=1, 2=don't care, 3=unknown, 4=notUsed Bit4-2: Onhook D: 0=0, 1=1, 2=don't care, 3=unknown, 4=notUsed Bit1: Sig Inject BIt0: Sig Extract |
chnl_type | smallint | channel type |
cndt_crtr_indx | smallint | conditioning criterion index |
tx_ab_sgnl | smallint | transmit AB signalling: (This applies to Tx/Rcv XY sig) Bit7-5: Tx/Rcv X signalling Bit4-2: Tx/Rcv Y signalling 0=sig bit is 0, 1= sig bit is 1, 2=tx sig bit transparently, 3=don't tx sig bit, 4=Reverse/Inverse sig bit Bit1=0: Spare |
tx_cd_sgnl | smallint | transmit CD signalling Same as tx_ab_sgnl |
rcv_ab_sgnl | smallint | receive AB signalling Same as tx_ab_sgnl |
rcv_cd_sgnl | smallint | receive CB signalling Same as tx_ab_sgnl |
sgnl_intgr_time | smallint | signalling integration time (ms) |
min_wink | integer | minimum wink (ms) (100 - 300) |
playout_delay | smallint | playout_delay (120 - 200) |
iec | smallint | iec parms: Bit7:echo cancel: 0=Disabled, 1=Enabled Bit6:non-linear proc: 0=Disabled, 1=Enabled Bit5:conv: 0=Disabled, 1=Enabled Bit4:echo return loss: 0=Low, 1=High Bit3:tone disabler: 0=Disabled, 1=Enabled Bit2:bkcd prefer: 0=Disabled, 1=Enabled Bit1:bkgnd filter: 0=Disabled, 1=Enabled Bit0:spare |
| Column Name | Data Type | Description |
|---|---|---|
con_obj_id | integer | connection object ID |
l_network_id | smallint | Network ID |
l_node_id | integer | Node ID |
shelf | integer | Shelf number |
l_slot | smallint | Slot number |
l_port | smallint | port number (zero based, only 0 is allowed) refer to vismChanPortNum in MIBs |
l_vpi | smallint | vismLocalVpi |
l_vci | integer | vismLocalVci |
l_nsap_addr | char(20) | vismLocalNSAP |
r_network_id | smallint | remote network ID |
r_node_id | integer | remote node ID |
r_slot | smallint | remote slot number |
r_port | smallint | remote port number |
r_vpi | smallint | vismRemoteVpi |
r_vci | integer | vismRemoteVci |
r_nsap_addr | char(20) | vismRemoteNSAP |
lcn | integer | vismCnfChanNum |
master_flag | smallint | vismMastership |
termination | smallint | Type of local and endpoints |
con_type | smallint | vismChanConnType |
sub_type | smallint | vismConnServiceType |
pvcType | smallint | vismChanPvcType |
vpcFlag | smallint | vismVpcFlag |
active | smallint |
|
status | smallint | connection status |
l_pcr | integer | vismConnPCR |
lper_util | smallint | vismConnPercentUtil |
r_pcr | integer | vismConnRemotePCR |
rper_util | smallint | vismConnRemotePercentUtil |
protect | smallint | vismChanProtection |
prefer | smallint | vismChanPreference |
actState | smallint | vismChanActivityState |
lockState | smallint | vismChanLockingState |
ingrScr | integer | vismChanScrIngress |
ingrMbs | integer | vismChanMbsIngress |
ingrClr | integer | vismChanClrIngress |
egrScr | integer | vismChanScrEgress |
egrMbs | integer | vismChanMbsEgress |
egrClr | integer | vismChanClrEgress |
application | smallint | vismChanApplication |
fallbackLcn | integer | vismChanFallbackLcn |
rmtLpbkState | smallint | vismChanLocRmtLpbkState |
cacMaster | smallint | vismChanCacMaster |
cacRejPolicy | smallint | vismChanCacRejectionPolicy |
reserved | integer | reserve field |
| Column Name | Data Type | Description |
|---|---|---|
network_id | smallint | CWM network ID |
node_id | integer | CWM node ID |
slot | smallint | Slot number |
rangenum | smallint | Range number |
port | smallint | Port number |
min_vpi | integer | Minimum VPI value |
max_vpi | integer | Maximum VPI value |
| Column Name | Data Type | Description |
|---|---|---|
network_id | smallint | Network ID |
node_id | integer | Node ID |
shelf | integer | Shelf number |
slot | smallint | Slot number |
controller | smallint | mgcNumber |
protocol | smallint | mgProtocolNumber |
port | integer | vismXgcpPeerPort |
reserved | integer | reserve field |
This section provides information about known anomalies and those corrected in the 9.2.09 release of CWM. The stat IDs for the QBIN statistics differ depending on whether the switch is running SWSW 9.1 or 9.2.
The following QBIN statistics have been added to the database structure for Trunk object (type 2) for BPX_ATM class (subtype 2) in Switch Software 9.1:
53 = Voice cells transmitted to line
54 = Time-stamped cells transmitted to line
55 = Non time-stamped cells transmitted to line
56 = High priority cells transmitted to line
57 = Bdata A cells transmitted to line
58 = Bdata B cells transmitted to line
160 = Tx CBR cells served
161 = Tx VBR cells served
162 = Tx ABR cells served
196 = Tx NTS Cells discarded
197 = Tx Hi-Pri Cells discarded
198 = Tx Voice Cells discarded
199 = Tx TS Cells discarded
200 = Tx BData A Cells discarded
201 = Tx BData B Cells discarded
202 = Tx CBR Cells discarded
203 = Tx ABR Cells discarded
204 = Tx VBR Cells discarded
205 = Egress NTS Cells Rx
206 = Egress Hi-Pri Cells Rx
207 = Egress Voice Cells Rx
208 = Egress TS Cells Rx
209 = Egress BData A Cells Rx
210 = Egress BData B Cells Rx
211 = Egress CBR Cells Rx
212 = Egress ABR Cells Rx
213 = Egress VBR Cells Rx
The following QBIN statistics have been added to the database structure for Trunk object (type 2) for BPX_ATM class (subtype 2) in Switch Software 9.2:
6 = Voice cells transmitted to line
7 = Time-stamped cells transmitted to line
8 = Non time-stamped cells transmitted to line
9 = High priority cells transmitted to line
10 = Bdata A cells transmitted to line
11 = Bdata B cells transmitted to line
18 = Tx CBR cells served
19 = Tx VBR cells served
20 = Tx ABR cells served
27 = Tx NTS Cells discarded
28 = Tx Hi-Pri Cells discarded
29 = Tx Voice Cells discarded
30 = Tx TS Cells discarded
31= Tx BData A Cells discarded
32 = Tx BData B Cells discarded
33 = Tx CBR Cells discarded
34 = Tx ABR Cells discarded
35 = Tx VBR Cells discarded
36 = Egress NTS Cells Rx
37 = Egress Hi-Pri Cells Rx
38 = Egress Voice Cells Rx
39 = Egress TS Cells Rx
40 = Egress BData A Cells Rx
41 = Egress BData B Cells Rx
42 = Egress CBR Cells Rx
43 = Egress ABR Cells Rx
44 = Egress VBR Cells Rx
This section provides information about known anomalies and those corrected in the 9.2.09 release of CWM. This section also provides information about anomalies known and corrected in current releases of WANCV.
| Bug ID | Description |
CSCdr82202 | The MGX 8230 bis_object table is not getting updated when a trunk goes down. Consequently, the status of the feeder trunk is not updated in NWTopology map. Workaround: Cold start the CWM workstation |
CSCdr75758 | Unknown error-message displayed when adding a connection in conn-mgr. Workaround: Use CLI. |
CSCdr76754 | When Total Cells Rx from Line statistics are enabled for SWSW 9.2 on CWM 9.2, Egress Q13 Cells Px was collected. Workaround: None. |
CSCdp94678 | SV+ Network and Service MIBs have invalid syntax. Workaround: None. |
CSCdp96799 | Unable to adjust the ABR TRM foresight above 100 in Con Mgr GUI Workaround: Use CLI. |
CSCdr16501 | Unable to set EgressQSelect in GUI for FRSM-2CT3 cards Workaround: Configure this parameter through Conn proxy. |
CSCdp82068 | In a very large network, sometimes Databroker cache has dangler PVCs which can't be deleted. Workaround: Coldstart CWM. |
CSCdr38573 | CWM 9.2.07, HPUX 10.20 install, INSTALL.INF missing endif statement Workaround: None. |
CSCdr55391 | UXM lines were showed as incorrect number in reports Workaround: None. |
CSCdr59882 | Sometimes all BPX lines were showed as x.0 on Network Browser Workaround: Coldstart or warmstart CWM. |
CSCdr50946 | Sometimes Connection manager and database is sluggish, PVC creates exceed 2 minute limit. Workaround: None. |
CSCdr72715 | STG Trap 27752 is received with a VPN name followed by comma. Workaround: None. |
CSCdr73396 | CWM database does not show new revisions of upgraded AXIS R5 shelves Workaround: Coldstart CWM. |
CSCdr65809 | Sometimes ConnProxy Modify takes up to 2 minutes for RPM-PXM PVC. Workaround: None. |
CSCdp37665 | Cannot install informix on to a Volume Manager device. |
CSCdp60175 | FASTPADS appear in submaps in 9.2.07. |
CSCdp63612 | Nwbrowser shows worng status for lines and ports |
CSCdp94323 | The Traffic Summary application displays CIR incorrectly. |
CSCdr20098 | Service Agent returns wrong value for Bc. |
CSCdr24778 | NIW should not be allowed on FR-ATM connections. |
CSCdr25617 | AXIS SM config unable to save with CWM on multiple nodes. |
CSCdr39084 | Error message while starting core, Logger Error : None. |
CSCdr59853 | CWM 9.2 - Error Desktop already running on this display with SSH. |
CSCdr72142 | Connections are incomplete and nodes reversed after upgrade to 9.02.8 |
CSCdk75148 | sview400 SNMP port delete not registered |
CSCdk87382 | When choosing all for ConnMgr under SecMgr, ConnMgr does not allow delete |
CSCdm07349 | RTMProxy core dump on sview machine |
CSCdm08471 | EMC core dumping continuously on sview machine |
CSCdm08489 | Cannot delete PVC using SNMP |
CSCdm29132 | Desktop won't start on svplus station |
CSCdm41308 | Cannot set svConnPrefRouteDesc |
CSCdm41639 | Cannot add more PVCs after 253 PVCs on cards. |
CSCdm42179 | SNMP port query of port that doesn't exist returns bad values instead failure |
CSCdm86541 | Frame Relay connection details are not being updated into the StrataView Plus database correctly |
CSCdp57162 | Cannot create BXM-FRSM PVC |
CSCdp94637 | SCM doesn't enable stats on all nodes unless restarted several times |
CSCdr00297 | Cannot create any rows in the cwmVismAal2CidCnfTable |
CSCdr01681 | When trying to configure a TDM VISM port, can't create svMgEndpointTable entry |
CSCdr09362 | Invalid state in vism_endpt table. |
CSCdr13635 | Cannot set svAtmPortCACOverride to disable for BXM UNI port |
CSCdr32501 | EMC core files are adding up and filling up file system on CWM machine |
CSCdr32530 | Cannot remove danglers via SNMP |
CSCdr38458 | SCM not enabling stats on swsw9.1.10 BPX node + collected stats are not saved |
CSCdr38830 | EMSC binary does not updated to support FRSM EIR field |
CSCdk61676 | Trap 20004 returns incorrect trapReason for clear state. |
CSCdm32149 | Trap reason code not found in the MIB |
CSCdm33600 | ATM user_connection.state value undefined |
CSCdm50410 | HPOV/trapd.log shows svplus as source for all BPX events |
CSCdm62276 | Invalid Database name prevents access to Desktop for all user |
CSCdm73552 | Cannot query IMA port via SNMP |
CSCdp48961 | Wingz statistics screen for Connections=>ATM CE connections is too small. |
CSCdp60172 | CWM 9.2.06: Bad usage of tm_year, inappropriate date in error messages |
CSCdp62571 | Selecting Multiple raw partition option fails during install |
CSCdp64083 | Gcra1 and Gcra2 Action not being set properly |
CSCdp65684 | Switchcc creates lots of userConnRouteChanged 25019 traps |
CSCdp66002 | CWM 9.2.05: CMGR unable to add a PVC with VPI=0 |
CSCdp80125 | Conn Mgr failed status of AUSM connection incorrect |
CSCdp80789 | CWM doesn't detect that a redundant BXM took over |
CSCdp86142 | STG Trap 27357 shows incorrect NeighborID |
CSCdp93849 | Trap 51209: ParConnAutoRemove not defined in StrataCom_trapd.conf |
CSCdp93893 | MGX Traps 50130, 50244 undefined in StrataCom_trapd.conf |
CSCdp93910 | VISM Traps 50756, 50754 undefined in StrataCom_trapd.conf |
CSCdp94689 | Trap 50053 diagStatusTrap undefined in StrataCom_trap.conf |
CSCdp96287 | Standalone SCMs poll network slowly, fails to retrieve all nodes |
CSCdr02150 | Trap 50728 has no format in StrataCom_trapd.conf |
CSCdr08180 | Need description update in SMIB for svConnAlarmVci (VPC values) |
CSCdr09925 | Non-svplus users cannot start desktop due to log file permissions |
CSCdr11918 | Cannot set svAtmPortQueueDepth to 20000 |
CSCdr16510 | EgressQSelect default value is incorrect in MIB |
CSCdr22466 | Sort is not done by local end point / CMGUI |
CSCdr24685 | Parameters mismatch between Wingz and SCM |
CSCdr24697 | Content of some Wingzs Statistics Selection screens are unreadable |
CSCdr25941 | Get fails for svAtmPortQueueparameters |
CSCdr29724 | FR-ATM Conversion factor not addressed via CWM |
CSCdr34548 | No trap definition in trapd.conf for VISM trap 50748 |
CSCdr38155 | No trap definition in trapd.conf for traps 50753, 50745, 50746 |
CSCdr40005 | SCM rescan node file does not work |
CSCdr53335 | Add Conn failed when atmEndPointMinAdjustPeriod set for ATM-ATM with ATFST |
CSCdr65907 | CWM GUI can't refresh FR T3 PVC conn status to OK after line is reconnected |
CSCdr69558 | SCM does not enable Ave Cells Tx Q depth stat for ASI Connection on BPX |
CSCdr70474 | Add Conn for FRM-FRSM FR-FR fails for frEndPointIntialBurstSize |
CSCdp42558 | MIB Cisco-C3800-mib.my will not load. |
CSCdp48117 | CWM automated startup script broken |
CSCdp57468 | Trap Reason codes 5019,5021 not defined in the MIB |
CSCdp73881 | Time Synchronization Node (nodename) field Edit Box Misplaced |
CSCdp80731 | ATM ABR.1 parameter External Segment Flow Cntl not enabled by CM templates |
CSCdp81473 | svConnLocalStr not defined in the Service MIB for RPM connections |
CSCdp90688 | CWM calculation for CES structured incorrect |
CSCdr21352 | VISM conns svConnTable:TrkAvoidType and ClassOfService return -1 |
| Bug ID | Description |
CSCdr91708 | Bad characters at node_type section in statsenablelist.stats |
CSCds07395 | Unable to conduct config save/restore using v.35 in MGX8220 HS1B |
| Bug ID | Description |
CSCdp33123 | Cannot set policing to none for FR-ATM PVC using conn-proxy. |
CSCdp37383 | Unable to set atmEndPointUPCEnable for an PXM end point. |
CSCdp41835 | RPM - PXM conn missing and meaningless values in atm_connection table. |
CSCdp48930 | Database not in sync; shelf table missing NEW shelves joining network. |
CSCdp56273 | OSS:Cannot add AUSM/FRSMCT3 PVC on CWM machine. |
CSCdp57162 | Cannot create bxm-frsm PVC. |
CSCdp61865 | Cannot discover 3810-v3 from network topology. |
CSCdp64061 | Cannot provision on subinterfaces 255 and 256; problem with Connection Manager. |
CSCdp66897 | svMapLogicalPort query fails after AXIS/AUSM non-IMA port addition. |
CSCdp68198 | Add Connections failed for RPM end points. |
CSCdp71164 | Node Resync on MGX 8850 feeder deletes user connections from CWM database. |
CSCdp78490 | EMD process coredump in the new 9.2.08E(patch1). |
CSCdp82018 | APS value incorrect in database. |
CSCdm50410 | HPOV/trapd.log shows svplus as source for all BPX events. |
CSCdp01954 | Service MIB incorrectly defines how to build VPCs. |
CSCdp06259 | Create cbr conn as disable oversubscription override, displays enabled in SNMP. |
CSCdp13370 | addnewuser is using inapproriate option for ID. |
CSCdp17420 | MPLS: Only 2 out 3 sgmnts RPM-AUSM connections are modified, when using conn proxy. |
CSCdp18857 | snmpwalk problems on PortProxy AtmPortTable. |
CSCdp19261 | IpAddress syntax not supported in Proxy. |
CSCdp19941 | No password confirmation in ConfigSave and ConfigRestore. |
CSCdp21004 | unable to set bbChanUpcSCR parameter on PXM for RPM-PXM conn |
CSCdp23192 | PR8386 Values of two routing attributes are switched in CWM. |
CSCdp24362 | Failure to install WandDest about a multiple disk machine. |
CSCdp33203 | Database schema documentation inconsistent. |
CSCdp33287 | unable to start WANDEST: invalid cisco.com. |
CSCdp35428 | Database not in sync; shelf table missing shelves. |
CSCdp39918 | Unable to add mapping to a standy card of a yred(LDM). |
CSCdp40168 | Add Connections fail in ConnProxy when mib variable AtmForeSight. |
CSCdp41288 | Failure to enable stat 58: Total Cells Rx from Line on BPX. |
CSCdp41396 | PXM stats names mismatch between SCM and MGX. |
CSCdp45113 | User connection type unknown for trap 25015: svUserConnModified. |
CSCdp48489 | Network Browser Routing Trunks section does not show virtual trunks. |
CSCdp48961 | Wingz statistics screen for Connections=ATM CE connections. |
CSCdp49441 | ATM policying not set to default variable. |
CSCdp52435 | snmpwalk failed on MGX 8220 FRSM port. |
CSCdp54704 | Known problems for VISM-AUSM support in Conn Proxy. |
CSCdp55520 | Test Con and Testdelay fails on CWM and it goes through CLI. |
CSCdp57713 | PVC addition has slower performance. |
CSCdp60172 | CWM 9.2.06: Bad usage of tm_year, inappropriate date in error. |
CSCdp63921 | SNMP problem adding DN to VISM. |
CSCdp64921 | Policing not being set properly from GUI on ATM connections. |
CSCdp65684 | Switchcc creates lots of userConnRouteChanged 25019 traps |
CSCdp65723 | Wrong trapReason code displayed for trap 20103 after a card |
CSCdp66002 | CWM 9.2.05: Connection manager unable to add a PVC with VPI=0. |
CSCdp69554 | Cannot query svCardEgrQOSFeature. |
CSCdp70044 | Connecton Manager eCAC feature is disabled. Initialization error: CAC file - invalid version. |
CSCdp71469 | MOD fails when atmEndPointICR is set. |
CSCdp71527 | Cannot modify connection to enable/disable Service Rate override. |
CSCdp72859 | %util via cli not reflected correctly in connectoin Manager. |
CSCdp73291 | Mod port failed for AUSM-IMA FC 8E1 |
CSCdm93240 | testcon tstdelay fails through proxy; the same passed through the CWM GUI. |
CSCdp28074 | Errors installing WANDEST client/server into same directory |
CSCdp55955 | Syntax of stgParentDeviceSlotNo is defined as String in the |
CSCdp63982 | CWM shows MGX8850 with cards that are not actually in the ch |
CSCdp78780 | 3810-V3 is not discovered through ILMI, unless ILMI is disab |
CSCdp76827 | efci_q_thresh is set to null in database for PXM segments - inconsistent. |
CSCdp82190 | IMA port info incorrectly deposited in ausm_port table. |
CSCdp79727 | No PVC failure traps when a line is failed on ipfr-popeye. |
CSCdp49403 | Trap 20011: portAlarm is not generated for BXM-OC3 card. |
CSCdp79151 | Failure/Clear of Sonetline does not generate all Trunking PVC fail/clears. |
CSCdp73960 | Connecton Manager GUI: RPM Incomplete Connection cannot be deleted. |
CSCdp74624 | Connecton Manager GUI: number of connections is wrong. |
CSCdp79406 | Unable to delete AUSM-VISM connection from user_connection table. |
CSCdp82123 | ConnProxy hangs in an infinite loop; core file found. |
CSCdk92186 | Connection manager GUI does not catch when Average value on RPM is out of range. |
| Bug ID | Description |
CSCdp80125 | Conn Mgr failed status of ausm connection incorrect |
CSCdp80147 | Port 1 on AUSM card missing in Conn Mgr. |
| Bug ID | Description |
CSCdp57468 | Trap Reason codes 5019,5021 not defined in the mib. |
CSCdp64083 | Gcra1 and Gcra2 Action not being set properly. |
CSCdp86142 | STG Trap 27357 shows incorrect NeighborId. |
CSCdp93849 | Trap 51209: ParConnAutoRemove not defined in StrataCom_trapd.conf. |
CSCdp93893 | MGX Traps 50130, 50244 undefined in StrataCom_trapd.conf. |
CSCdp93910 | VISM Traps 50756, 50754 undefined in StrataCom_trapd.conf. |
CSCdp94689 | Trap 50053 diagStatusTrap undefined in StrataCom_trap.conf. |
CSCdp21004 | Unable to set bbChanUpcSCR parameter on PXM for RPM-PXM conn. |
CSCdp91557 | Cannot bring up WANdest 9.2.08 CWM. |
CSCdp94637 | SCM doesnt enable stats on all nodes unless restarted several times. |
CSCdp92110 | ConnProxy : Add failure , RPM (VBR3, ABR1) VP tunnling. |
CSCdp33203 | Db Schema Documentation inconsistent. |
CSCdp09896 | Conn-proxy is returing in-coherent error message in svCmpaErrorLastDesc. |
CSCdp96513 | SA_SCM does not collect stats from all nodes. |
CSCdp82077 | CWM shows AXIS shelf attached to 2 nodes (Platform Selection). |
CSCdp25736 | SNMPwalk on protGroup has several problems. |
| Bug ID | Description |
CSCdr01681 | When trying to configure a TDM vism port, cant create svMgEndpointTable entry. |
CSCdr00297 | Cannot create any rows in the cwmVismAal2CidCnfTable. |
CSCdr00320 | CWMdb does not store proper values. |
CSCdp86321 | PortProxy -- errorTable is not updated properly for cwmVismDs0CnfTable. |
CSCdp87941 | Add Port failed for BXM OC3. |
CSCdr02593 | Unable to delete a vpc from ausm/pxm to rpm. |
CSCdr03916 | Missing/Incomplete pvc in DB & CMGUI with mgx8850 rel 1.1.22. |
CSCdp25736 | Walk on protGroup has several problems. |
CSCdr04221 | MGX shelfs are not being displayed in Conn. Mgr window. |
CSCdp80731 | ATM ABR.1 parameter External Segment Flow Cntl not enabled by CM templates. |
CSCdp97274 | CWM fails to establish links with gateway node after disconnection from LAN. |
| Bug ID | Description |
CSCdr07538 | CWM 9.2.07 Patch 8 snmp failures when removing PVC. |
| Bug ID | Description |
CSCdp86321 | PortProxy -- errorTable is updated improperly for cwmVismDs0CnfTable. |
CSCdr00343 | Deleted PVC, when re-added get a dangler. |
CSCdr09328 | LineProxy - errorTable and signalling type are missing from the SV+Service.mib. |
| Bug ID | Description |
CSCdp95296 | .CWM 9.2: WanMgr alarm hierarchy not working. |
CSCdp95303 | .CWM 9.2: Trap filtering is failing. |
CSCdr07538 | 9.2.07P8 snmp failures when removing PVC. |
CSCdp81473 | svConnLocalStr not defined in the Service MIB for RPM connections. |
CSCdp94678 | .SV+Network and Service MIBS have invalid syntax. |
CSCdp01954 | Service mib incorrectly defines how to build VPCs. |
CSCdp93327 | Wierd MIB syntax SV+Service.mib :svConnPrefRouteDesc. |
CSCdp41501 | Trap 50993, trapBbChanFailed, is not generated when channel fails. |
CSCdr08046 | Cannot provision rpm-rpm and rpm-pxm pvcs via SNMP 9.2.08 P3 IOSMGR/EXPECT. |
CSCdp94060 | Receiving UserConnection Modification traps 25015 for no reason. |
| Bug ID | Description |
CSCdr18606 | Performance problems - Adding a PVC through Proxy takes more time. |
| Bug ID | Description |
CSCdr11948 | CMGRD sends incorrect RPM logical_port(1) to databroker. |
CSCdr13635 | Cannot set svAtmPortCACOverride to disable for BXM UNI port. |
CSCdp94678 | SV+Network and Service MIBS have invalid syntax. |
CSCdr02150 | Trap 50728 has no format in StrataCom_trapd.conf. |
CSCdr11918 | Cannot set svAtmPortQueueDepth to 20000. |
CSCdr16510 | EgressQSelect default value is incorrect in MIB. |
CSCdp84063 | Cant disable FBTC on BPX segment of conn via CM. |
CSCdr07538 | 9.2.07P8 snmp failures when rehoming PVC. |
| Bug ID | Description |
CSCdr17636 | Problem provisioning BXM UNI port / SNMP. |
CSCdr21352 | VISM conns svConnTable:TrkAvoidType and ClassOfService return -1. |
CSCdj52072 | Bpx switch accepts %util=0 for UBR connection. |
CSCdr06438 | Service Agenet does not properly update %UTIL when provisioning. |
| Bug ID | Description |
CSCdr25941 | Get fails for svAtmPortQueueparameters. |
| Bug ID | Description |
CSCdr21352 | VISM conns svConnTable:TrkAvoidType and ClassOfService return -1. |
CSCdr22466 | Sort is not done by local end point / CMGUI. |
CSCdr35842 | Dbg statements for New Object at inproper level from PPortQPar.C |
CSCdr25178 | emc coredump at sview300 at calling GetDbVismConn(). |
CSCdr32501 | Emc core files are adding up and filling up file system on cwm machine. |
CSCdr32530 | Cannot remove danglers via snmp. |
CSCdr33863 | Deleted BXM port still shows up in GUI. |
CSCdp64590 | IGX feeder connected to BPX is not visible in NWBrowser. |
CSCdr38830 | EMSC binary does not updated to support FRSM EIR field. |
CSCdr41364 | Fine tune Dbg statements in PFrsmConn.C and resync.C. |
CSCdr41369 | Shared memory tuning for large network in CWM script. |
CSCdp64590 | IGX feeder connected to BPX is not visible in NWBrowser. |
| Bug ID | Description |
CSCdr25266 | user_connection table not getting populated after successfull add/mods of FRSM endpt conns. |
CSCdr38458 | SCM not enabling stats on swsw9.1.10 bpx node and collected stats are not saved. |
| Bug ID | Description |
CSCdr45306 | STG Traps 27551 and 27552 are not defined in the MIB. |
CSCdr24685 | Parameters mismatch between Wingz and SCM. |
CSCdr24697 | Content of some Wingzs Statistics Selection screens are unreadable. |
| Bug ID | Description |
CSCdr53335 | Add Conn failed when atmEndPointMinAdjustPeriod set for atm-atm with atfst. |
CSCdr29724 | .FR-ATM Conversion factor not addressed via CWM. Please note you need to enable ATM_FR_OVERHEAD_FLAG in the config file in order to activate the fix for CSCdr29724. The location of the config file is /usr/users/svplus/config/cmgrd.conf. |
CSCdr15570 | .Trap#50022 does not mention specific trunk during switch-over. |
CSCdp49596 | ECN Threshold shows up as zero in one segment BXM - FRM connection. |
CSCdp89024 | ECN Threshold mapping not correct for one segment BXM-FRM connection. |
| Bug ID | Description |
CSCdr60230 | SNMP walk cwmDsx1VismCnfGrpTable is not retrieving data for all entries. |
CSCdr31360 | CWM database still has dangler PVCs even though deleted at switch. |
CSCdr65907 | CWM GUI cant refresh FR T3 PVC conn status to OK after line is reconnected. |
CSCdr56735 | Customer unable to plot raw data element TxABR Cells Discarded report. |
CSCdr61321 | emc coredumping. |
CSCdj52072 | .bpx accept %util=0 for UBR connection. |
CSCdr53335 | Add Conn failed when atmEndPointMinAdjustPeriod set for atm-atm with atfst. |
CSCdp69558 | SCM does not enable Ave Cells Tx Q depth stat for ASI Connection on BPX. |
| Bug ID | Description |
CSCdr34548 | No trap definition in trapd.conf for VISM trap 50748. |
CSCdr38155 | No trap definition in trapd.conf for traps 50753, 50745, 50746. |
CSCdr56051 | STG Trap 26101 CtrlStateChanged received with invalid stgState. |
CSCdr45364 | When OAM Loopback fails, con fail trap not received until con downed. |
CSCdr65907 | CWM GUI cant refresh FR T3 PVC conn status to OK after line is reconnected. |
CSCdr82329 | Can not set the Q depth for FRM-BXM ATFST using CWM 9.2.08 patch 15. |
| Bug ID | Description |
CSCdr91708 | Bad characters are present at node_type section in statsenablelist.stats. |
| Bug ID | Description |
CSCdp38307 | If shelf is unreachable during a cold start, CWM does not register upon recovery. Workaround: None. |
CSCdp22795 | Lines switched Trap 20105 is not received for all events. Workaround: None. |
CSCdp41488 | Trap 50037, secLineModuleMismatchTrap, is not generated. Workaround: None. |
CSCdp41501 | Trap 50993, trapBbChanFailed, is not generated when channel fails. Workaround: None. |
CSCdp42659 | No trap definition in trapd.conf for trap 50052: atmLineCellFormatTrap. Workaround: None. |
CSCdp06240 | Cannot modify PVCs through GUI on AUSM-AUSM connections. Workaround: Modify PVC through connection proxy. |
CSCdp41835 | RPM to PXM conn missing and meaningless values in atm_connection table. Workaround: Cold start CWM station. |
CSCdp35428 | Database not in sync - shelf table missing shelves. Workaround: Cold start CWM station. |
CSCdp41330 | conn_type in atm_connection table showed as frame relay. Workaround: None. |
CSCdp37636 | Installation reports no disk space in /usr/users when using Vol Manager. Workaround: None. |
CSCdp37665 | Cannot install informix on to a Volume Manager device. Workaround: None. |
CSCdp21891 | Traceroute command no longer works in 9.2, even with correct permissions. Workaround: None. |
CSCdp42401 | Statistics file on CWM does not match that of the Switch 9.2.21. Workaround: None. |
CSCdp28154 | RPM-PXM PVC deletion is intermittent. Workaround: None. |
CSCdp38188 | Unable to compile MIBS using mosy. Workaround: None. |
CSCdp41288 | Failure to enable stat 58: Total Cells Rx from Line on BPX. Workaround: None. |
CSCdp41375 | New enabled stats in statsenablelist.stats not listed on SCM GUI. Workaround: None. |
CSCdp41396 | PXM stats names mismatch between SCM and MGX. Workaround: None. |
CSCdp38470 | Deleted PVC (PXM-RPM) but still show in Database. Workaround: Cold start CWM station. |
CSCdp28984 | /usr/users file system on CWM machine full. Workaround: Delete files manually. |
CSCdp39710 | ILB error causes core startup to fail/hang. Workaround: restart CWM station. |
| Bug ID | Description |
CSCdp38470 | Deleted a PVC (PXM-RPM) but it still shows in the Database. |
CSCdp42659 | No trap definition in trapd.conf for trap 50052: atmLineCellFormatTrap. |
| Bug ID | Description |
CSCdp29151 | STG trap 26102, variable, stgResult returns incorrect value. |
CSCdp48928 | Entry is not removed from vism_card table when VISM card is removed from shelf. |
| Bug ID | Description |
CSCdp33123 | Cannot set policing to none for FR-ATM PVC using conn-proxy. |
CSCdp37383 | Unable to set atmEndPointUPCEnable for an PXM end point. |
CSCdp01954 | Service MIB incorrectly defines how to build PVCs. |
CSCdp45113 | User connection type unknown for trap 25015: svUserConnModified. |
CSCdp28984 | /usr/users file system on CWM machine full |
CSCdp41396 | PXM stats names mismatch between SCM and MGX. |
CSCdp33203 | Db Schema Documentation inconsistent. |
| Bug ID | Description |
CSCdp57162 | Cannot create BXM-FRSM PVC. |
| Bug ID | Description |
CSCdp06259 | Create CBR connection as, disable oversubscription override, displays enabled in SNMP. |
CSCdp41396 | PXM stats names mismatch between SCM and MGX. |
CSCdp49441 | ATM policing not set to default variable. |
CSCdp55955 | Syntax of stgParentDeviceSlotNo is defined as String in the STG MIB. |
CSCdp50544 | Excessive DB update for frp table. |
CSCdp66002 | CWM 9.2.05: CMGR unable to add a PVC with VPI=0. |
| Bug ID | Description |
CSCdp41835 | RPM <-> PXM connection missing and meaningless values in atm_connection table. |
CSCdp64061 | Cannot provision on subinterfaces 255 and 256, problem with cmgrd. |
CSCdp63921 | SNMP problem adding DN to VISM |
CSCdp63982 | CWM shows MGX8850 with cards that are not actually in the chassis |
CSCdp48930 | Database not in sync - shelf table missing NEW shelves joining network. |
CSCdp38307 | If shelf is unreachable during cold start, CWM does not register upon recovery. |
CSCdp31912 | Card table not in sync with dspcds in popeye. |
CSCdp60172 | CWM 9.2.06: Bad usage of tm_year, inappropriate date in error messages. |
CSCdp68290 | All Delete cases failed with error from proxy, unable to locate local endpt. |
CSCdp68279 | All modify cases fail with an error from proxy, no remote endpoint info. |
CSCdp66897 | svMapLogicalPort query fails after AXIS/AUSM non-IMA port add. |
CSCdp67379 | Rate_up,rate_down becomes -1 on RPM ABR1 cons, after setting successfully. |
| Bug ID | Description |
CSCdp43898 | RPM-RPM incomplete local DAX connection can not be deleted on stand alone POPEYE. |
CSCdp55955 | Syntax of stgParentDeviceSlotNo is defined as String in the STG MIB. |
CSCdp06259 | Create cbr connections as disable oversubscription override, displays enabled in SNMP. |
CSCdp64061 | Cannot provision on subinterfaces 255 and 256, problem with cmgrd. |
CSCdp71164 | Node Resync on POPEYE feeder deletes User connections from CWM database. |
CSCdp79503 | Missing/Incompelete pvcs in DB & CMGUI, show OK on POPEYE CLI. |
| Bug ID | Description |
CSCdp65684 | Switchcc creates lots of userConnRouteChanged 25019 traps. |
CSCdp82018 | APS value incorrect in Database. |
CSCdp82123 | ConnProxy hangs, expect in infinite loop, core file. |
CSCdp82190 | IMA port info incorrectly deposited in ausm_port table. |
| Bug ID | Description |
CSCdp86211 | Trap 50311 not defined in trapd.conf; trap missing two varbinds defined in the MIB. |
CSCdp01954 | Service MIB incorrectly defines how to build VPCs. |
CSCdp79727 | No PVC failure traps when a line is failed on ipfr-popeye. |
| Bug ID | Description |
CSCdp24005 | CWM not able to sync up with very large 9.2.05 network -- some feeder shelves are missing. |
CSCdp26561 | CWM 9.2.05 not registered with 19 out of 24 AXIS nodes after sync-up. |
CSCdp29327 | APS data not defined in dbschema. |
CSCdp30561 | packet_line.aps_flag not set. |
CSCdp30615 | Frame PVC add hangs on CWM machine. |
CSCdp36130 | Cannot modify CIR for RPM to PXM connections. Workaround: None |
CSCdm90761 | EMSC core dumps every 1 second repeatedly. |
CSCdp01954 | Service mib incorrectly defines how to build VPCs |
CSCdp03929 | Missing mib valuues for asynchronousUpdate MIB object |
CSCdp06259 | Create CBR connections as disabled oversubscription override, displays enabled in CWM connection proxy |
CSCdp12997 | STG trap 26101 stgState value defined as integer in mib, transmitted as octet. |
CSCdp15357 | STG does not create traps if a 3810 router if no entry in CWM /etc/host file |
CSCdp19352 | Default policing parameters bbChanGcra1Action and bbChanGcra2Action are not set correctly |
CSCdp21203 | CWM 9.2.05 will not start, no data from network |
CSCdp22665 | Unknown SubType deen in CWM Node Table |
CSCdp22829 | APS disabled on the line, however, trap 20102 is not received |
CSCdp28222 | No Trap received for User connection modification |
CSCdp30214 | STG is not creating/sending trap for TRAP 26142, 26004 |
CSCdp32636 | Cannot provision PVC on MGX/RPM |
CSCdp36756 | Any frame pvc snmp failure on popeye returns incorrect error messages |
| Bug ID | Description |
CSCdp14071 | Cannot Create Connections from Connection Manager GUI on svplus. Workaround: Cold start CWM |
CSCdm64116 | When re-homing ATMFR PVC, delete successful then add fails with dangler error. Workaround: retry PVC provision |
CSCdm89230 | 3810 state not reported correctly in the Network Topology GUI. Workaround: cold start CWM |
CSCdp02365 | Cannot do tstcon/testdelay in SNMP for AUSM-BXM PVCs; always returns -2. Workaround: None |
CSCdp05802 | Node is in Minor alarm while color is grey. Workaround: cold start CWM |
CSCdp06240 | Cannot modify PVCs through GUI on AUSM-AUSM connections. Workaround: None |
CSCdp10900 | VP tunneling ADD for AUSM.E1 to BXM.OC3. Workaround: None |
CSCdp12714 | Network Browser does not shows lines and ports on UXM card. Workaround: None |
CSCdp12999 | Receiving physical line status clear trap when trunk is in Major-LOS. Workaround: None |
CSCdp13002 | Trap 1006 dumps all varbinds fro ds3StatsErrors. Workaround: None |
CSCdp13370 | addnewuser is using inappropriate option for id Workaround: None |
CSCdp14310 | Starting CWM Core returns a watchdog error for STG process Workaround: Restart CWM core |
CSCdm04988 | CWM shutdown prints an error message on kill command. Workaround: None |
CSCdm25333 | Connection manager does not support for MBS and SCR parameters for ABR connection on pxm. Workaround: None |
CSCdm94347 | Network Topology, Feeder trunks show in major alarm when added dynamically. Workaround: None |
CSCdp00795 | ADD FR-FR connections failed with err frEbdPtChanServType not modifiable. Workaround: None |
CSCdp01954 | Service MIB incorrectly defines how to build VPCs. Workaround: None |
| Bug ID | Description |
CSCdm38338 | Unable to add RPM-PXMUNI (3 segment) connections using the Connection Manager GUI. |
CSCdm68386 | Cannot create or configure FR-FR connections using the Connection Manager GUI. |
CSCdm72081 | Addition of 3-segment RPM connection fails with an error indicating MBS out of memory. |
CSCdm73718 | Walking MIB svPortAlarmPortType of CWM hangs the system for two minutes. |
CSCdm76242 | Statistics Collection Manager (SCM) is not performing Time Sync with stand-alone MGX 8850 nodes. |
CSCdm771129 | CNMS MIB walk via Conn Proxy slows when RtmProxy is forced to RTM mode. |
CSCdm78283 | Unable to add 3-segment FR-FR connections using the Connection Manager GUI. |
CSCdm79138 | CWM does not correctly add 3-segment FR-FR connections to MGX 8830. |
CSCdm79474 | Cannot update fields using Connection Manager GUI. |
CSCdm80751 | CWM does not recognize FRSM-HS1/B ports. |
CSCdm81353 | Cannot walk MIB svPortAlarmPortType due to incomplete node data. |
CSCdm82212 | Cannot add 3-segment FRSM-2T3 connections due to VBR-RT failure. |
CSCdm82917 | Cannot modify ATM-FR VBR3 connections. |
CSCdm84499 | Connection Manager GUI displays the error dialog for an invalid port ID. |
CSCdm85436 | smain core dumps occurred when start core on MGX 8850 devices. |
CSCdm85450 | eventd core dumped when starting core |
CSCdm85476 | Connection Manager GUI core dumps when bringing up slot or port list for MGX 8830 PDT. |
CSCdm85477 | Cannot add abr.fs connections with ForeSight PCR set. |
CSCdm85490 | Cannot add abr.fs connections with ForeSight PCR set. |
CSCdm85526 | atmEndPointforesightPCR continues to take values from the old PCR01. |
CSCdm86288 | Cannot create ATM-FR, VBR3 or ATM-FR, BRFS connections with Conn Proxy. |
CSCdm86685 | Conn Proxy with patch 3 software fails to modify AUSM end connections. |
CSCdm87312 | Addition of ATM-FR connections fail for subtypes UBR1 and UBR2 for FUNI ports. |
CSCdm87655 | Network Topology care dumps when ILMI configuration is changed on AUSM port. |
CSCdm87709 | Network Topology core dumps when trunk state changes in Level III map. |
CSCdm88876 | SCM failed to send enable.statistics to all nodes in CWM 9.2.05 patch 3. |
CSCdm90590 | Unable to set rpmEndPointPeak |
CSCdm90646 | syslog trap generator (STG) core dumps at start of core. |
CSCdm90783 | Con proxy fails to modify connections with one AUSM 91044end point because of ForeSight set. |
CSCdm91044 | Attempts to modify AUSM end point connections fail with error of wrong service rate value. |
CSCdm92282 | In a lab environment, svAtmPortSpeed MIB walk returns invalid address values. |
CSCdm92403 | Errors while starting up CWM, may be because of 3810 project additions |
CSCdm92703 | ConnProxy can not modify/delete CESM end point connections |
CSCdm94215 | ConnProxy transaction timeouts experienced by provisioning engine |
CSCdm94289 | SNMP request getting timeouts on CWM running 9.2.05 patch #3. |
CSCdp00805 | MOD RPM test cases failing with error Agent returned NO SUCH NAME |
CSCdp02664 | 9.2.06L emc does not populate line table at all |
CSCdp02671 | emc dumped core |
CSCdp02688 | HPOV install patch failed with errors |
CSCdp04175 | Cannot set statistics enable for 8830 on CWM_SCMSA |
CSCdp05302 | PXM OC3 Port data being stored in AUSM_Port table. |
CSCdp05809 | vism_mgcp table is not getting populated in the data base |
CSCdp05880 | Database SQL logic error introduced by code generator |
CSCdp06148 | Database inconsistency between switch and SV+ leading to failure in conn.pro |
CSCdp06228 | Cannot perform test-delay on any connection using Service MIB in 9.2(5 |
CSCdp06505 | Database does not get populated |
CSCdp07083 | The pollerd process in PFM NMS is shutting down sometimes |
CSCdp07535 | Modify of all FRSM end connections fail with an error internal error |
CSCdp08066 | rtm core dumps in 9.2.06M |
CSCdp08392 | PFM NMS does not move PVC to different node when there is a node power |
CSCdp09097 | Controller table missing from db |
CSCdp09486 | ConnProxy, fails to create abr-fs connection for AUSM-BXM endpoints |
CSCdp09554 | In presence of unreachable nodes in network, pollerd process cannot start |
CSCdp09750 | Line table inconsistent |
CSCdp10354 | xgcp_peer port number does not get updated in the DB |
CSCdp10642 | Unable to set xgcp_peer port through emd |
CSCdp11898 | Statistics reports (WINGZ) does not have option of displaying MGX ports |
CSCdp12642 | The MIB files for the 3810 and STG (syslog trap generator) not in release. |
CSCdk84906 | In Connection Manager the GUI shows a wrong value for MCR (rpm) in ATM-ATM connections. |
CSCdm50410 | HPOV/trapd.log shows svplus as source for all BPX events |
CSCdm50451 | Not able to add DAX Connection between CESM E3s on MGX 8850 through Conn Poxy.r |
CSCdm63768 | Lots of Alarm states for line and ports are displayed Unknown(-1) in N |
CSCdm65832 | patch releases do not include version identifier file |
CSCdm68531 | Failure to add a Time Sync node not on selected node list |
CSCdm70029 | Connection Manager Alarm Suppression is not working properly |
CSCdm71563 | SA SCM: Node Name field has no restrictions |
CSCdm73552 | Cannot query IMA port via SNMP |
CSCdm74325 | Network Browser shows down lines status as Clear or Unknown(-1) |
CSCdm74763 | CiscoView displays green (enabled) for disable line 2 of FRSM-2T3E3 |
CSCdm75405 | SA SCM Configurator: No confirmation dialog is displayed when removing |
CSCdm75767 | Non integer VPI.VCI combination interpreted as 0.0 by Connection Manager GUI |
CSCdm76459 | ConnProxy.log dumps too much garbage while running svConnAlarmConnType |
CSCdm76649 | ATM-FR connections added through CLI appear as FR-FR on GUI |
CSCdm76957 | CWM Connection Manager displays wrong value for service rate incase of 0 CIR c |
CSCdm77605 | CiscoView 8830 node display should be different than SES-IGX node display. |
CSCdm78167 | Failure to make UBR connections using CWM GUI for FRSM-VHS service mod |
CSCdm79516 | Network Browser issues |
CSCdm81379 | Update: WANDEST does not install in csh or borne shell |
CSCdm83430 | ConnProxy core dumps 9.2.04 patch 9CSCdm83696 ATM Cell header HEC Errors stat is not supported in release 9.2 |
CSCdm84930 | Standalone MGX8830 fail resync: Configurator needs Model MGX8830 not M |
CSCdm87140 | Inconsistency in trap#50312 bet. AXIS shelf and HPOV |
CSCdm87794 | Network Topology, trunk status unknown when Trunk recovers from alarm |
CSCdm89141 | Network Topology, Alarm status not seen on Level 11 & III submaps |
CSCdm89449 | Release field in IlogTopodNodeMsg_s struct is null |
CSCdm91758 | STG, syslog messages being logged to sys.old.log instead of sys.log file. |
CSCdm92155 | CWM autostart does not work. |
CSCdm92435 | ConnProxy should bloc connection addition with wrong SubType. |
CSCdm92999 | STG, traps are not send in user readable format to Rtmproxy |
CSCdm93201 | Proxy adds a CBR1 ATM-FR connection as nrtVBR not as HI priority |
CSCdm93853 | Network Topology IMA Feeder Trunk Memory Leaks |
CSCdm94048 | Trap 50135 dumps all varbinds in trapd.log |
CSCdm95230 | CWM 9.1.06 could not be upgraded to 9.2.04 as defined in upgrade procedure. |
CSCdp00794 | MOD CESM 4T1 connections failed with error Wrong MaxBufSize |
CSCdp00811 | Connection Manager GUI: RPM MODIFY |
CSCdp02812 | WANDEST client displays files in the PST time instead of GMT. |
CSCdp04327 | Unable to create FR-FR multi-segment connection on MGX 8850 nodes via Connection Manager. |
CSCdp06259 | Create cbr connection as disable oversubscription override, displays enabled |
CSCdp06983 | Modify problems in Connection Manager GUI for ATMFRCBR1 cases |
CSCdp07746 | svMGAdminstate parameter set fails with wrong oid message |
CSCdp08909 | PER 71, conversion error for SNMP get request for atmendpointForesight |
CSCdp09896 | conn-proxy is returning in-coherent error message in svCmpaErrorLastDes |
CSCdp09990 | Wrong varbind for rpmPort subinterface in trapd.log. |
CSCdp10675 | atmQbinHiClp not displayed in qbin table |
CSCdp11903 | Statistics reports (WINGZ) does not display objects of Axis Sonet types |
CSCdm66959 | Nodes does not show in topology if database name is not stratacom |
CSCdm67152 | MIB should specify the card type if one or more cards have same parameter |
CSCdm71558 | SA SCM: No help available on Node Configuration in SCM Configurator |
CSCdm77121 | BPXs do not show up in Statistics collection Manager. |
CSCdm79966 | Need to narrow FW version support down to for FRSM-8 and RSM-VHS on PO |
CSCdm81862 | Connection Manager GUI 0-CIR failed on UBR |
CSCdm84870 | Alarm Status on Network Topology GUI does not refresh after failure |
CSCdm84969 | Modification of Service Rate MIB does not give error message in Conn Proxy |
CSCdm87320 | FUNI connection on ATM-FR cbr1 does not choose default parameters automatically. |
CSCdm88356 | Network Topology, select Singapore background distorts map layout |
CSCdm88431 | The node name sent by topod is router.cisc^A for a node named router.c |
CSCdm88824 | Modification failed for connection with 0 CIR on a BXM-FRSM 2E3 connection. |
CSCdm89222 | Network Topology, Request for trunk alarm propagation for clusters |
CSCdm89378 | Mod Service Rate always not required |
CSCdm90373 | Errors in stratacom_tarpd.conf file |
CSCdm90374 | Configurator exits if DISPLAY verifiable is not set (with out any errors). |
CSCdm90618 | CWM network browser lists PXMs and SRMs with invalid slot numbers |
CSCdm90858 | Launching IP Manager through Network Topology GUI is unable to pick the correct DISPLA |
CSCdm91706 | Network Topology, Level II map does not dynamically detect name/ip changes |
CSCdm91708 | Network Topology, Adding nodes for Level II and III maps not updated dynamic |
CSCdm93946 | Conn Proxy adds an ATM-FR connection with default channel type as NIW. |
CSCdm94588 | Network Topology, ghosting effect when 3810 added to routing node |
CSCdm91999 | Statistics are not showing up properly in Wingz. |
CSCdp0449 | ConnProxy did not reject attempt to modify frEndPointchanType of activity. |
CSCdp00561 | Display error in pollerd.log in LDM/HDM Port Fail over NMS |
CSCdp03478 | VISM card in the database has two fields missing. |
CSCdp03900 | ConnProxy fails to reject an improper PVC modify operation |
CSCdp04124 | Message logged by NMS log for non-DTR leads is not clear |
CSCdp04840 | PFM NMS is wrongly interpreting all kinds of traps as heartbeat traps |
CSCdp09450 | SCM statsenablelist.statistics has duplicate statid for different statistic name |
CSCdp10282 | ConnProxy, PER 71 AUSM-BXM & AUSM-UXM abr-fs connection MIB value incorrect |
CSCdp18888 | Query to port Speed returns -1 |
CSCdp19024 | INCs to INCs data PVC creation fails |
CSCdp19072 | Adding BXM-FRSM PVC fails. |
CSCdp05302 | PXM OC3 Port data is being stored in AUSM_Port. |
CSCdp12985 | Need to add ethernet port failure in facility. |
CSCdp12972 | OBJECT-TYPE stgState (administratively up). |
CSCdp12997 | STG trap 26101 stgState value defined as integer. |
CSCdp09092 | Conn-proxy returns incoherent error message. |
CSCdp09950 | Bad varbind for line numbers for traps trap 50132,50133, and others. |
CSCdp18611 | Difference in Schema for upgrade from 9.1.06 to 9.2.06. |
CSCdp17277 | DB schema difference during upgrade. |
CSCdp13167 | Port_type for PXM ports should not be -1. |
CSCdp19013 | CWM does not return correct logical port. |
CSCdp09051 | Error message when Ciscoview is installed. |
CSCdp14071 | Cannot Create Connections from Connection Manager GUI. |
| Bug ID | Description |
CSCdp26561 | CWM not registered with 19 out of 24 AXIS nodes after synchronization. |
CSCdp24005 | CWM not able to synchronize with large 9.2 network -- some feeder shelves missing |
| Bug ID | Description |
CSCdp29286 | New image pxm1.1.12KK is not recognized as PXM 1.3 image by emc in 9.2.06 & 07 |
| Bug ID | Description |
CSCdp35428 | Database not in sync - shelf table missing shelves. |
Table 34 lists the known anomalies in CWM 9.2.05 with a description of the problem.
Bug ID | Description |
|---|---|
CSCdm50265 | SNMP addition of PVC gives timeout and channel oversubscribe on MGX 8850. |
CSCdm55926 | Databroker dies on CWM workstation after warm-start. Workaround: Restart CWM. |
CSCdm56837 | SV+ machines will not synchronize with the network. This problem is intermittent and only occurs on a very large network. Workaround: Restart CWM. |
CSCdm33677 | No MIB variable defined for MCR for PXM UNI ports. No work around exists. |
CSCdm40692 | Wrong severity is received by HPOV and NetView when clearing alarm on IGX 8400. No work around exists. |
CSCdm47444 | Databroker: Inefficient logic to flag nodes with incomplete (uncommitted) segments. No work around exists. |
CSCdm50254 | Query for total connections in a given switch in Connection Manager GUI is taking too long. No work around exists. |
CSCdm54197 | CDVT0+1 allowed range different in GUI from proxy and switch. No work around exists. |
CSCdm54366 | Connection Manager shows wrong alarm status for FRSM-HS1 to FRSM-HS1 DAX connection. No work around exists. |
CSCdm54875 | CWM does not properly see the MGX 8850. No work around exists. |
CSCdm37703 | Could not add CE-CE connections or ATM-CE connections due to "fail to update" disk errors. No work around exists. |
CSCdm58248 | Syntax error in the INSTALL script during CWM installation. No work around exists. |
CSCdm17657 | Connection Manager and Databroker - PVC modify: Do not detect ILOG (synchronous) timeout. No work around exists. |
CSCdm25333 | Connection Manager does not support for MBS and SCR parameters for ABR connection on PXM. No work around exists. |
CSCdm27641 | AIS/OAM status are shown as OK in upgraded while new 9.2 shows as --. No work around exists. |
CSCdm49488 | All Platforms: When starting, NWBrowser complains about requiring a "--w." No work around exists. |
CSCdm55231 | Ilb Error message consistently showing in CWM window. No work around exists. |
CSCdm55889 | SCM GUI Error Log does not show write permissions denied errors. No work around exists. |
CSCdm62433 | Incomplete PVC traps after deletion. No workaround exists |
CSCdm63698 | PVC clear traps are missing in trapd.log. No work around exists. |
CSCdm65832 | Patch releases do not include version identifier. No workaround exists. |
CSCdm64116 | When rehoming ATMFR PVC, delete successful, then add fails with dangler error. No workaround exists. |
CSCdm66147 | The number of SCM children in 9.2.04 is limited to 3 due to the ILOG interface. No workaround exists. |
CSCdm68531 | Failure to add time sync node that is not in the selected nodes list. No workaround exists. |
CSCdm64435 | CWM machine not recovering from IP connection problem. No workaround exists. |
CSCdm68287 | Upgraded CWM and newly installed CWM differs. No workaround exists. |
This section describes anomalies corrected in the 9.2.05 version of Cisco WAN Manager.
Bug ID | Description |
|---|---|
CSCdm18381 | CMGUI can not see the ports on a primary BXM card after the Y-red switchover. |
CSCdm40244 | CWM Console Message: watchdog error: Process iosmgr, pid = <xxx> no longer restarted. |
CSCdm51117 | snmpget on last sequence number fails and can not GET from host other than registered manager. |
CSCdm58835 | While setting the RPM-RPM connections, the option to set ciscooppp for encapsulation from ConnProxy will result in connection failure. Workaround: Use CMGUI for adding RPM-RPM connections with ciscooppp as the encapsulation type. |
CSCdm60138 | ConnProxy: RPM-FR connection fails. |
CSCdm63275 | Stats enable was only being sent to first node selected in the node list. Workaround: Select nodes one by one. |
CSCdm65490 | GetEndParam stored procedure is not created from the file GetEndParam.sql during installation. |
CSCdm66492 | Card data are not populated completely in the CWM database. |
CSCdm54209 | While modifying an RPM-FRSM connection with maximum values, popeye7 returns a "Fore sight not enabled" error. |
CSCdm62240 | For FR-ATM PVCs, wrong end points were given in User Connection, Traps #25016 and #25017. |
CSCdm62259 | When an End to End PVC is deleted from the CMGUI, a User Connection Incomplete Trap (#25014) is sent to CMGUI and HP/OV (as expected). At the same time, however, an unexpected User Connection Clear Trap (#25016) is also sent to HP/OV. |
CSCdm63596 | socketd dies after killing svmain (due to incorrect ILOG license) |
CSCdm66978 | SV+ generates a CommBreak trap with wrong varbinds which do not match with the SV+ Network MIB. |
CSCdm58562 | Opening a 6th session of CiscoView through the Equipment Manager for an Axis shelf, displays the "Already running 5 Ciscoview sessions" error message and also pops up another window saying "Ciscoview - Work in progress." This occurs only while bringing up the 6th session for an Axis shelf, but works properly for other shelves. Also, the pop up window remains displayed and does not go away. |
CSCdm59869 | When adding a slave end point of a connection, CWM duplicates the remote NSAP/VPI/VCI with the local NSAP/VPI/VCI. |
CSCdm48725 | When the Topology window is clicked the second time, the window does not come up. If it is iconified, it stays iconified. |
| Bug ID | Description |
CSCdm67880 | ATM-FR VBR3 connection addition fails when FRSM VHS is on one end. |
| Bug ID | Description |
CSCdm79138 | Added a 3-segment FR-FR (8E1) connection from an MGX8830 to a Popeye shelf. The MGX8830 is a CMGUI reports that the connection has been added successfully. Aftera few seconds, it tells me the connection has been deletedand is now "Incomplete". Checked the connection on the CLI and all the segments are intact. |
CSCdm68386 | The following log message showed up, reproducable, in ConnMgr.log when tried to create a new FR-FR connection using CM GUI on igx38-popeye8. ( 4583) 18:01:40 L2: /usr/users/svplus/config/insd.conf open failure: errno = 2 ( 4583) 18:01:40 L2: <UpdateInsdTableLocation>: failed reading insd config file ( 4583) 18:01:40 L2: <AniConnExistsForEndPt> Unable to update insd tables location ( 4583) 18:01:40 L2: /usr/users/svplus/config/insd.conf open failure: errno = 2 ( 4583) 18:01:40 L2: <UpdateInsdTableLocation>: failed reading insd config file ( 4583) 18:01:40 L2: <AniConnExistsForEndPt> Unable to update insd tables location |
| Bug ID | Description |
CSCdm78283 | Attempted to add connections, but connections didn't get added. The following error message was seein in the result window of the conn. mgr. GUI Cmgr: b4-bpx2: 08/03/99 07:02:12 from Mgr 172.29.28.63 :: SET AtmEndptTable Row 65535 (CREATE) PCR(0+1) value out of range (local end). Valid range 50 - 96000. |
CSCdm80751 | emc1.log show the following messages. ( 8079) 02:23:05 L3: EMC1 RECEIVED TFTP RESPONSE 53 STATUS 1 ( 8079) 02:23:05 L3: EMC1 RECEIVED TFTP RESPONSE POPEYE@SM_1_14.CF.45 ( 8079) 02:23:05 L4: EMC1 CHECKSUM OK FOR TFTP FILE /usr/users/svplus/tmp/POPEYE@SM_1_14.CF.45 ( 8079) 02:23:05 L3: New CardInformation data found in the file: slot = 14, realSlotNum =14 ( 8079) 02:23:05 L2: Expected card not in file for retrieved slot 14 ( 8079) 02:23:05 L3: FINISHED PARSING FILE FOR SLOT 14 ( 8079) 02:23:05 L3: <chkForSecondary> Slot 14 is not a Secondary ( 8079) 02:23:06 L3: SENDING RESYNC STATUS 4 TO GUI - Configuration upload failed for slots: 11, 13, 14 outOfSync 26624 ( 8079) 02:23:06 L3: SEND RESYNC STATUS 4 TO EMD Configuration upload failed for slots: 11, 13, 14 ( 8079) 02:23:06 L3: RESYNC FOR NODE 45 COMPLETED status 4 Configuration upload failed for slots: 11, 13, 14 The root cause was from misinformation on maximum number of cards available on Sweetpea node. It was set to 12. Now it is raised to 14. |
CSCdm87487 | Unable to see an MGX8500(connected to a BPX) on the Stats Manager GUI to send stats enable to. |
CSCdm77121 | Ttwo MGX-8850s that are configured as feeder nodes off of two BPXs do not show up in their Stats Mgr GUIs underConfig, Node Selection. Only the BPXs appear. |
| Bug ID | Description |
CSCdm88876 | SCM does not send stats.enable to all selected nodes. |
CSCdm83696 | ATM HEC errors is not supported in 9.2 SWSW under BPX-ATM Trunks. |
CSCdm88875 | The log file "statinlog.stats" is not getting updated with the most recent events. |
CSCdm84964 | The correct value for channel service rate and override service rate did not get updated due to wrong upload config table get loaded. |
CSCdm89390 | Set Override Srv. Rate to Yes. Change rate to 3.84 which valid in the range of 3.84 to 153600.00, But CMGUI came out dialog with "Terminating Service Rate ...." |
| Bug ID | Description |
CSCdm95230 | SubType binary was missing due to the build problems & hence DB upgrade used to fail during Installation. |
| Bug ID | Description |
CSCdm83613 | Sets the QIR value equal to PIR using 2 SNMP sets to the endpoints. Upon doing this, the service agent changes %UTIL to %100. |
CSCdm94215 | Provisioning engine is experiance timeouts due to transaction end-to-end timespan. |
CSCdm90618 | The DB query to list the card information was wrong & is corrected. |
| Bug ID | Description |
CSCdp06228 | TestConn and TestDelay fail for a FRSM-FRSM connection through ConnProxy. The SNMP-SET returns with GenErr. TestConn/TestDelay can be performed through CMGUI fine. |
| Bug ID | Description |
CSCdp35428 | Database not in sync. Shelf table is missing shelves. |
This section describes anomalies corrected in the 9.2.04 version of Cisco WAN Manager.
Bug ID | Description |
|---|---|
CSCdm46772 | Cannot set svAtmPortQueue parameters on AUSM port until five minutes after creating the port. |
CSCdm47154 | HP/OV will not start after the CWM install. |
CSCdm47458 | When deleting incomplete PVCs, the ConnProxy dies. |
CSCdm48712 | Trap loading issues and error log on hpov_ins. |
CSCdm48731 | Connection Manager GUI core dumped when a BPX 8600 node was selected. |
CSCdm51715 | Extremely slow 9.2 RTM performance on the CWM machine. |
CSCdm52063 | emsc core dumps after loading the 9.2.04A build. |
CSCdm52274 | Multiple Connection Manager GUI core dumps while running ConnProxy test automation. |
CSCdm55565 | Trap is not generated after warmstart of CWM. |
CSCdm55825 | SNMPAgent.conf file missing and causing all Proxies to die while starting CWM. |
CSCdm57221 | ConnProxy adds a VP connection when given a VCI value 0. |
CSCdm57445 | SNMP query of frEndPointPercUtil always returns 100 percent. |
CSCdm57504 | Problem with parsing RTM trap in GET response. |
CSCdm03156 | SCM stats enable for Broadband interfaces chops the selected stats window. |
CSCdm14322 | After switchcc, the logical slot was incorrect in card table. |
CSCdm26812 | Connection Manager GUI not accepting VCI value 0. |
CSCdm44609 | SA_SCM on workstation does not function. |
CSCdm45189 | emsd and databroker processes die the fifth time after restarting the CWM process. |
CSCdm46326 | portSpeed mismatches in CLI and CWM for FRSM_HS1B.V35 card. |
CSCdm47827 | Cannot delete incomplete middle segment using the Connection Service Agent. |
CSCdm48333 | CWM needs to support UXM XLR SONET mode. |
CSCdm48467 | Alarm Hierarchy is missing from emsd.conf in the 9.2.03 build. |
CSCdm48516 | Desktop will not start for non-svplus user. |
CSCdm48725 | Topology button does not work the second time after exiting. |
CSCdm50410 | HPOV/trapd.log shows svplus as source for all BPX events. |
CSCdm50420 | HPOV/trapd.log shows incomplete messages after deleting FR-ATM PVCs. |
CSCdm50451 | Not able to add DAX connection between CESM E3s on MGX 8850 through the Conn proxy. |
CSCdm50477 | Port speed mismatch on CESM T3. |
CSCdm50802 | RPM user connection traps are identified as ATM instead. |
CSCdm51905 | Connection Manager failed because of version checking. |
CSCdm53123 | CWM does not allow adding VP Tunnel connection through CMGUI. |
CSCdm54847 | Parameter settings in 9.2.03 required. |
CSCdm55958 | Incorrect sequence number for the first trap. |
CSCdm15107 | Need to remove StrataView reference in SvOvTopology. |
CSCdm38454 | Undefined variable in INSTALL. |
CSCdm47635 | After clicking on NWBrowser, an error message stating this option requires an argument --w. |
CSCdm56865 | CWM does not see incomplete MGX 8800 segments. |
| Bug ID | Description |
CSCdp29331 | VISM1.5: SRCP Port Number parameter should be read-only. |
| Bug ID | Description |
CSCdp54840 | VISM1.5: Cannot read or configure VISM Ds0s. |
CSCdp26328 | VISM1.5: Cannot configure xgcpCapabilityPackageEnable. |
CSCdp26991 | VISM1.5: vismRemoteVpi, vismRemoteVci, vismRemoteNSAP read only. |
CSCdp26271 | VISM1.5: Cannot modify Channel Protection and Locking State. |
CSCdp26247 | VISM1.5: Changing Channel Preference parameter in CiscoView. |
CSCdp29498 | VISM1.5: Cannot create new row in Configured Protocols. |
CSCdp29520 | VISM1.5: CiscoView display wrong protocol number. |
CSCdp59598 | VISM1.5: CiscoView displays wrong dsoIfIndex in VISM Ds0s table. |
CSCdp68660 | VISM 1.5: Values for Available DS0s and Codec Template are switched. |
CSCdp68681 | VISM 1.5: CAC Enable/Disable field appears blank. |
CSCdp59605 | VISM 1.5: Cannot modify vismCcsChannels parameter in CiscoView. |
CSCdp67959 | VISM 1.5: vismCasFileName field should be read-only. |
CSCdp69743 | VISM 1.5: VISM Ds0s table in CiscoView doesnt display consistent number of rows. |
CSCdm39836 | Mib lacks definition for 8 port BNC connector. |
| Bug ID | Description |
CSCdk86469 | CiscoView is not lighting port lights (BPX front view). |
CSCdp42553 | CiscoView IGX package does not highlight SR-BC ports. |
| Bug ID | Description |
CSCdp21852 | CiscoView does not discover RPM backcard MMF |
CSCdp16004 | VISM1.5: Values in Packetization Period |
CSCdp26279 | VISM1.5: Domain Name and IP Address parameter |
CSCdp26290 | VISM1.5: Row Status parameter in Internal Name |
CSCdp26311 | VISM1.5: Controller Domain Name should be read-only |
CSCdp26319 | VISM1.5: Cannot configure Shutdown Grace Timer |
CSCdp26323 | VISM1.5: Default Package Name cannot be configured |
| Bug ID | Description |
CSCdm53985 | Cisco View allows addition of imagrp with ITC clock mode |
CSCdm78415 | Help not functional for Logical Port counters and service queue dialogs |
CSCdm67254 | A Pr3 CV messaging Cant read tab(-2,0): no such element in array for BXM interface. |
| Bug ID | Description |
CSCdm63213 | CiscoView allows read-only users to change port. Workaround: none |
CSCdm91201 | CiscoView does not display device configuration information. Workaround: none |
CSCdp03929 | Missing MIB values for asynchronousUpdate. Workaround: none |
The known anomalies in WANCV 2.04 are listed in Table 35 with descriptions of the problems.
Bug ID | Description |
|---|---|
CSCdm53985 | Symptom: Cisco View allows addition of imagrp with ITC clk mode. Workaround: None |
CSCdm35649 | Symptom: CiscoView does not display 1:N redundancy activated indication on the SRM. Workaround: None |
CSCdm24069 | Symptom: Network events are not always displayed in the Event Browser, nor do they appear in the trapd.log file. This is an intermittent problem. Workaround: None |
CSCdm65675 | Symptom: The BPX 9.1.13 is stored as 9.1.1.3 in the Cisco SV+ 9.1.08 node table. Workaround: None |
This section describes anomalies corrected in the WANCV 2.04.
Bug ID | Description |
|---|---|
CSCdm63213 | Symptom: CiscoView allows read-only users to change port parameters. |
This section describes anomalies corrected in the WANCV 2.03.
Bug ID | Description |
|---|---|
CSCdm46308 | Symptom: Cosmetic issue regarding back connectors v35. |
This section describes anomalies corrected in WANCV 2.02.
Bug ID | Description |
|---|---|
CSCdk86469 | Symptom: The BPX front card images don't get the status LED colors updated for line or trunk status changes. Workaround: View the line or trunk status on the rear view of the BPX. |
CSCdm06256 | Symptom: Due to a missing definition in the SWSW 9.1 MIB, CiscoView IGX device package V 2.01 fails to display UXM 8 T1 backcard with BNC connectors. Workaround: None |
This section describes anomalies corrected in the 2.01 version of WANCV.
Bug ID | Description |
|---|---|
CSCdm11640 | Symptom: CiscoView displays wrong status of BNM-T3 backcards. |
CSCdm17996 | Symptom: CiscoView cannot bring up logical ports in IGX-SES. |
CSCdm74769 | Symptom: UFM line status is not shown correctly on CiscoView. |
CSCdm30292 | Symptom: Standby SRM shows enabled lines. |
CSCdm30047 | Symptom: CiscoView does not show empty slot 8/24 as full-height. |
CSCdm35432 | Symptom: CiscoView MGX 8850 device package should display Wide Area Switch. |
CSCdm28304 | Symptom: LED does not glow for T3/E3 lines of IMATM. |
This section describes anomalies corrected in the 2.00 version of WANCV.
Bug ID | Description |
|---|---|
CSCdk05434 | Symptom: Some MIB variables were defined as Integers instead of as Counters in axis.my. This caused the CiscoView monitoring dialogs to display them as numbers instead of the normal counter display. A large number of variables were redefined as Counter instead of Integer in axis.my. Workaround: Use the CLI commands to view counter objects. This defect was fixed in AXIS.pkg version 1.03. |
CSCdk07747 | Symptom: The status color updates for the BNM connectors were fixed in AXIS.pkg, version 1.03. |
CSCdk18768 | Symptom: This bug is fixed as a side effect of fix for CSCdk51704. SNMP sessions were unreliable, causing the updating of the monitoring dialogs to fail intermittently. Workaround: This defect was fixed in AXIS.pkg version 2.00. |
CSCdk21445 | Symptom: This defect was fixed along with other performance and index problems in AXIS.pkg version 1.03. |
CSCdk20837 | Symptom: This defect was fixed along with other performance and index problems in AXIS.pkg version 1.03. |
CSCdk21358 | Symptom: The MIB variable slotCardStatus does not show the proper value. Conditions: The IPX/IGX/BPX SNMP agent reports the above MIB variable as active when there is no backcard installed. |
CSCdm14151 | Symptom: The label for frLportPortSpeed was enhanced to clearly show the units of 100's of bits per second. This feature enhancement is available in IGX.pkg version 2.00. |
CSCdk57700 | Symptom: When using CiscoView to configure a port on an SRM3T3 card on an AXIS shelf, there is no option to configure the line type to dsx3M23, which is available at the CLI and in the MIB. dsx3LineType OBJECT-TYPE SYNTAX INTEGER { dsx3CbitParity(1), g832-g804(2), dsx3M23(3) } ACCESS read-write STATUS mandatory DESCRIPTION This variable indicates the variety of DS3 C-bit or E3 application implementing this interface. The type of interface affects the interpretation of the usage and error statistics. The rate of DS3 is 44.736 Mbps and E3 is 34.368 Mbps. The dsx3ClearChannel value means that the C-bits are not used except for sending/receiving AIS. The values, in sequence, describe: TITLE: SPECIFICATION: dsx3CbitParity ANSI T1.107a-1989. Transport of SDH elements on PDH networks ITU-T G.832 ATM cell mapping into PDH ITU-T G.804 ::= { dsx3ConfigEntry 2 } |
CSCdk91145 | Symptom: Occasionally, CiscoView BPX device package does not light red LED for card failure on its screen. Conditions: BPX switch software 9.1.06 CiscoView 4.2(1.0) BPX4.2(2.0V) package included in SV+9.1.05patch4 for Solaris. Workaround: The fix is available in versions later than 2.00W. |
CSCdm06256 | Symptom: UXM card with BNC connectors on IGX displays incorrectly in CiscoView 4.2 rear view. Conditions: CiscoView 4.2 /usr/users/svplus/wancv/IGX.pkg Version 4.2(1.10). |
The following documents, along with this Release Notes document, comprise the Cisco WAN Manager 9.2.09 documentation set:
Cisco Connection Online (CCO) is Cisco Systems' primary, real-time support channel. Maintenance customers and partners can self-register on CCO to obtain additional information and services.
Available 24 hours a day, 7 days a week, CCO provides a wealth of standard and value-added services to Cisco's customers and business partners. CCO services include product information, product documentation, software updates, release notes, technical tips, the Bug Navigator, configuration notes, brochures, descriptions of service offerings, and download access to public and authorized files.
CCO serves a wide variety of users through two interfaces that are updated and enhanced simultaneously: a character-based version and a multimedia version that resides on the World Wide Web (WWW). The character-based CCO supports Zmodem, Kermit, Xmodem, FTP, and Internet e-mail, and it is excellent for quick access to information over lower bandwidths. The WWW version of CCO provides richly formatted documents with photographs, figures, graphics, and video, as well as hyperlinks to related information.
You can access CCO in the following ways:
For a copy of CCO's Frequently Asked Questions (FAQ), contact cco-help@cisco.com. For additional information, contact cco-team@cisco.com.
Cisco documentation and additional literature are available in a CD-ROM package, which ships with your product. The Documentation CD-ROM, a member of the Cisco Connection Family, is updated monthly. Therefore, it might be more current than printed documentation. To order additional copies of the Documentation CD-ROM, contact your local sales representative or call customer service. The CD-ROM package is available as a single package or as an annual subscription. You can also access Cisco documentation on the World Wide Web at http://www.cisco.com, http://www-china.cisco.com, or http://www-europe.cisco.com.
If you are reading Cisco product documentation on the World Wide Web, you can submit comments electronically. Click Feedback in the toolbar and select Documentation. After you complete the form, click Submit to send it to Cisco. We appreciate your comments.

![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Thu Aug 31 21:28:35 PDT 2000
Copyright 1989-2000©Cisco Systems Inc.