cc/td/doc/product/rtrmgmt/cwm/9_2_00
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

Save and Restore Configuration Commands

Save and Restore Configuration Commands

This appendix contains descriptions of save and restore configuration commands. More information will be provided for the next review cycle of this document.

Caution
Restoring configurations to wide-area switch nodes should be done by a System Administrator.

Note The examples shown in this appendix are for IPX wide-area switch nodes. The command use is similar for BPX 8600 series nodes. Enter the command without any parameters to see the correct syntax for your environment and software release.

This appendix contains descriptions of the following save and restore configuration commands:

dspcnf (Display Configuration Save/Restore Status)

Use this command to display the status for the configuration save/restore processes on all nodes in the network.

Syntax

dspcnf

Function

The display lists the various nodes, the backup ID name of the saved configuration, the time and date saved, and the Cisco WAN Manager (CWM) workstation upon which it is saved. See Figure A-1 for an example.

When the status displays "Reserved for Firmware" a firmware image is present or being loaded. Use the getfwrev 0.0.0 command to clear a firmware image.


Figure A-1: dspcnf---Display Configuration Save/Restore Status
beta             CWM       StrataCom        Rev: 9.1 Sep. 8 1998 14:16 MDT 
 
Node     Backup ID   Revision    Date/Time (GMT)   Status 
-------- --------- ------------------------- --------------------------------- 
beta     R62Sep08    9.1.A       09/08/98 17:20:38   Save on CWM at beta complete 
alpha    R62Sep08    9.1.A       09/08/98 17:20:39   Save on CWM at beta complete 
gamma    R62Sep08    9.1.A       09/08/98 17:20:39   Save on CWM at beta complete 
 
 
 
Last Command: dspcnf 
 
Next Command: 
 
Attributes

Privilege Level: 0

Jobs: No

Log: No

Associated Commands

loadcnf, runcnf, savecnf

loadcnf (Load Configuration)

Use this command to load a configuration image from CWM into a node.

Syntax

loadcnf <backup_id> | clear> <node_name> | * <source_SV_node>

where:

<backup_id>

The name of the backup configuration file to be loaded.

clear

Clears the NPC buffer area before the configuration file is loaded.

<node_name>

Indicates the target node where the backup configuration file is to be loaded.

*

Specifies to load the backup configuration file on all nodes.

<source_SV_node>

The node connected to CWM where the configuration file is stored.

Function

This command loads the specified IPX configuration from CWM and stores it in a buffer area in PCC memory. The load configuration process runs in the background and may take several minutes depending on configuration file size.

When the status displays "Reserved for Firmware", a firmware image is present or being loaded. Use the getfwrev 0.0.0 command to clear a firmware image.

Once loaded, the configuration may be restored into the NPC's BRAM main memory using the runcnf command.

After using the loadcnf and runcnf commands to restore a configuration to a node(s), the PCC buffer area used for this purpose, should be cleared using the clear option of either the savecnf or loadcnf commands. This clearing of the buffer permits it to be used for future downloading processes.

Refer to Section "savecnf (Save Configuration)" for details on how to store a configuration onto the CWM workstation.

Attributes

Privilege Level: 0

Jobs: Yes

Log: Yes

Associated Commands

dspcnf, runcnf, savecnf

runcnf (Run Configuration)

Use this command to restore a network configuration image at a node.

Syntax

runcnf <backup_id> <node_name> | *

where:

<backup_id>

The name of the backup configuration file loaded from CWM. The <backup_id> must be 1-8 alphanumeric characters with the first character alphabetic.

<node_name>

Indicates the target node to rebuild with the new configuration.

*

Rebuilds all nodes using the new configuration.

Caution
Restoring configurations to BPX 8600 series and IPX wide-area switch nodes should only be done by the System Administrator with Customer Service assistance. Care must be taken to run all network nodes with the same configuration or abnormal network operation will occur.
Function

This command causes the specified IPX network configuration to be restored into the BRAM memory of the specified node(s), overwriting the current configuration. Once restored, the specified node(s) are rebuilt with the restored configuration image. The rebuilding process takes a few minutes for each node.

This command is usually run after a previous configuration has been lost and the specified node needs to be reconfigured. When in doubt as to the configuration being run at other nodes in the network, load the new configuration into all nodes by specifying "*" for the node name. The new configuration must have previously been loaded into the node's buffer area with the loadcnf command.

The system may display two warning messages in response to the runcnf command. When a single node is specified:

Warning - node_name not reachable. Continue? Y/N.
 
Warning - node_name does not have the specified configuration.   Continue? Y/N.
 

When all nodes are specified:

Warning - all nodes not reachable. Continue? Y/N.
 
Warning - all nodes do not have the specified configuration.   Continue? Y/N.
 

When a single node can not be reached, responding with a yes does not affect the operation of the network. When all node(s) do not have the specified configuration or are unreachable, we recommend you do not continue until the problem is resolved.

Attributes

Privilege Level: 0

Jobs: No

Log: Yes

Associated Commands

loadcnf, savecnf

savecnf (Save Configuration)

Use this command to save a node configuration image on a CWM workstation.

Syntax

savecnf <backup_id> | clear <node_name> | * <dest_SV_node>

where:

<backup_id>

Name of configuration to be saved on CWM. The <backup_id> must be 1-8 alphanumeric characters with the first character alphabetic.

clear

Clears the buffer area.

<node_name>

Node name on which to save configuration.

*

Indicates all nodes.

<dest_SV_node>

Node name where CWM is connected, which will receive the specified <backup_id>.

Function

This command causes the specified BPX 8600 series and IPX node configuration to be saved on a CWM workstation. Once saved, the configuration may be restored into BRAM using the loadcnf and runcnf commands. This command should be executed periodically, as well as after making any configuration changes on a network.

When the status displayed is "Reserved for Firmware", a firmware image is present or being loaded. Use the getfwrev 0.0.0 command to clear a firmware image.

The savecnf command takes a snapshot of the IPX BRAM and sends it to a buffer in the node. Each node, in turn, transmits the snapshot of its BRAM from the buffer to the CWM workstation for storage. This process takes a few minutes per node.

After loading and restoring a network configuration, the PCC/NPC buffer area used for this purpose should be cleared using this command's clear option. Clearing the buffer permits it to be used for future downloading processes.

Attributes

Privilege Level: 0

Jobs: Yes

Log: Yes

Associated Commands

dspcnf, loadcnf, runcnf


hometocprevnextglossaryfeedbacksearchhelp
Posted: Wed Mar 31 15:20:35 PST 1999