|
|
This appendix contains a collection of tables that provide lists of front and back cards supported in Release 10 of CWM based upon the card platform.
![]() |
Note The values listed in the Value column refer to the specific card type mnemonic used in the database tables. |
Table D-1 lists the IPX, IGX, and BPX front cards supported in Release 10 of CWM and the fc_type value associated with each front card.
| Front Card Type | Value (fc_type) |
|---|---|
NULL_CD | 0 |
IPX_PCC_CD | 1 |
VDP_CD | 2 |
TXR_CD | 3 |
PIC_CD | 4 |
VCD_CD | 5 |
VDP_VCD_CD | 6 |
PSM_CD | 7 |
PS_CD | 8 |
SDP_CD | 9 |
BSLOT_CD | 10 |
MBACK_CD | 11 |
SDP_BACK_CD | 12 |
TXR2_CD | 13 |
XDP_CD | 14 |
LDP_CD | 15 |
XDP_BACK_CD | 16 |
LDP_BACK_CD | 17 |
SBACK_CD | 18 |
LBACK_CD | 19 |
FDP_CD | 20 |
CIP_CD | 21 |
NTC_CD | 22 |
UBACK_CD | 23 |
UNI_CD | 24 |
FRP_CD | 25 |
FBACK_CD | 26 |
FRP_BACK_CD | 27 |
MT3_CD | 28 |
CDP_CD | 29 |
E1T1_PORT_CD | 30 |
ATM_CD | 31 |
NPC_CD | 32 |
ARC_CD | 33 |
AIT_CD | 34 |
FTC_CD | 35 |
FTCBACK_CD | 36 |
UFM1_CD | 37 |
UFM1_U_CD | 38 |
BTM_HP_CD | 39 |
UVM_CD | 40 |
UXM_CD | 41 |
BCC_CD | 101 |
ASM_CD | 102 |
BNI_T3_CD | 103 |
BNI_E3_CD | 104 |
MFRP_CD | 105 |
ASI_T3_2_CD | 106 |
ASI_E3_2_CD | 107 |
ASI0_T3_CD | 108 |
ASI0_E3_CD | 109 |
BNI_OC3_CD | 110 |
ASI_OC3_CD | 111 |
BPX_BSLOT_CD | 112 |
BCC3_CD and BCC4_CD1 | 113 |
Not Used | 114 |
Reserved for GIM Cards | 115 |
Reserved for GIM Cards | 116 |
MNCH_CD (BXM bpx only)) | 117. For other BXM card types, see Table D-2. |
BME | Refer to Table D-2. |
UNKWN_CD | 118 |
BXM T3 8 Ports | 1802 |
BXM T3 12 Ports | 184 |
BXM E3 8 Ports | 188 |
BXM E3 12 Ports | 192 |
BXM OC3 4 Ports SMF | 196 |
BXM OC3 4 Ports MMF | 197 |
BXM OC3 4 Ports SMLR | 198 |
BXM OC3 4 Ports SNM | 199 |
BXM OC3 8 Ports SMF | 200 |
BXM OC3 8 Ports MMF | 201 |
BXM OC3 8 Ports SMLR | 202 |
BXM OC3 8 Ports SNM | 203 |
BXM OC12 1 Ports SMF | 204 |
BXM OC12 1 Ports MMF | 205 |
BXM OC12 1 Ports SMLR | 206 |
BXM OC12 1 Ports SNM | 207 |
BXM OC12 2 Ports SMF | 208 |
BXM OC12 2 Ports MMF | 209 |
BXM OC12 2 Ports SMLR | 210 |
BXM OC12 2 Ports SNM | 211 |
BME_OC12_1_SMF | 212 |
BME_OC12_1_MMF | 213 |
BME_OC12_1_SMFLR | 214 |
BME_OC12_1_SNM | 215 |
BME_OC12_2_SMF | 216 |
BME_OC12_2_MMF | 217 |
BME_OC12_2_SMFLR | 218 |
BME_OC12_2_SNM | 219 |
| 1 Switch does not distinguish between BCC32 and BCC. To identify BCC card type uniquely use first character of fc_hw_rev field in card table. 2 Below values are for BXM (Monarch) card. Following DB tables uses these values: asi_line (field name card_type) card (field name fc_type) packet_line (field name card_type) |
Table D-2 lists the IPX, IGX, and BPX back cards supported in Release 10 of CWM and the bc_type value associated with each front card.
| Back Card Type | Value (bc_type) |
|---|---|
NULL_BCD | 0 |
RS232_BCD | 1 |
RS449_BCD | 2 |
V35_BCD | 3 |
RS232D_BCD | 4 |
RS232_8_BCD | 5 |
RS232_4_BCD | 6 |
FRIV35_4_BCD | 7 |
E1_BCD | 8 |
T1_BCD | 9 |
PCCB_BCD | 10 |
DDS_4_BCD | 11 |
DDS_8_BCD | 12 |
SR_BCD | 13 |
MT3_BCD | 14 |
FRI_E1_BCD | 15 |
FRI_T1_BCD | 16 |
J1_BCD | 17 |
Y1_BCD | 18 |
IPX_T3_BCD | 19 |
IPX_E3_BCD | 20 |
FRI_X21_BCD | 21 |
ARI_BCD | 22 |
AIT_T3_BCD | 23 |
AIT_E3_BCD | 24 |
FTIV35_4_BCD | 25 |
FTI_X21_BCD | 26 |
FTI_E1_BCD | 27 |
FTI_T1_BCD | 28 |
AIT_E2_BCD | 29 |
AIT_HSSI_BCD | 30 |
UFI_T1D_BCD | 31 |
UFI_E1D_BCD | 32 |
UFI_E1B_BCD | 33 |
UFI_HSSI_BCD | 34 |
UFI_V35_BCD | 35 |
UFI_X21_BCD | 36 |
BTM_HP_T3_BCD | 37 |
BTM_HP_E3_BCD | 38 |
BCC_BCD | 101 |
LM_ASM_BCD | 102 |
T3_BCD | 103 |
E3_BCD | 104 |
T3_2_BCD | 105 |
E3_2_BCD | 106 |
SMF_BCD | 107 |
MMF_BCD | 108 |
BCCLM2_BCD | 109 |
STM1_BCD | 110 |
UTP_BCD | 111 |
STP_BCD | 112 |
MNCH_BCD | 113 |
SMFLR_BCD | 114 |
UNKWN_BCD | 115 |
INIT_BCD | 116 |
BTM_HP_E3_BCD | 38 |
BCC_BCD | 101 |
LM_ASM_BCD | 102 |
T3_BCD | 103 |
E3_BCD | 104 |
T3_2_BCD | 105 |
E3_2_BCD | 106 |
SMF_BCD | 107 |
MMF_BCD | 108 |
BCCLM2_BCD | 109 |
STM1_BCD | 110 |
UTP_BCD | 111 |
STP_BCD | 112 |
MNCH_BCD | 113 |
SMFLR_BCD | 114 |
UNKWN_BCD | 115 |
INIT_BCD | 116 |
UAI_4OC3_MMF | 150 |
UAI_4OC3_SMF | 151 |
UAI_2OC3_SMF | 152 |
UAI_6T3 | 153 |
UAI_3T3 | 154 |
UAI_6E3 | 155 |
UAI_3E3 | 156 |
UAI_8T1_IMA_DB15 | 157 |
UAI_8E1_IMA_DB15 | 158 |
UAI_8E1_IMA_BNC | 159 |
UAI_4T1_IMA_DB15 | 160 |
UXM_4E1_IMA_DB15 | 161 |
UXM_4E1_IMA_BNC | 162 |
Table D-3 lists the MGX 8220, MGX 8850, Release 1, and MGX 8850, Release 2 front cards supported in Release 10 of CWM and the fc_type value associated with each front card.
| Front Card Type | Value (fc_type) | Symbols in the MIB |
|---|---|---|
asc | 2 |
|
bnm-T3 | 10 |
|
bnm-E3 | 11 |
|
bnm-155 | 12 |
|
srm-4T1E1 | 20 |
|
srm-3T3 | 21 | cevMGXSrm3t3 |
frsm-4T1 | 30 |
|
frsm-4E1 | 31 |
|
frsm-4T1-C | 32 |
|
frsm-4E1-C | 33 |
|
frsm-hs1 | 34 | cevFrsm4x21 |
frsm-8T1 | 35 | cevFrsm8t1 |
frsm-8E1 | 36 | cevFrsm8e1 |
frsm-hs1/b | 37 |
|
ausm-4T1 | 40 |
|
ausm-4E1 | 41 |
|
ausm-8T1 | 50 | cevAusm8t1 |
ausm-8E1 | 51 | cevAusm8e1 |
ausm-b-8t1 | 52 |
|
ausm-b-8e1 | 53 |
|
cesm-4T1 | 60 |
|
cesm-4E1 | 61 |
|
imatm-T3T1 | 70 |
|
imatm-E3E1 | 71 |
|
imatm-8T1-B | 72 |
|
imatm-8E1-B | 73 |
|
Frasm-8T1 | 80 |
|
cesm-8T1 | 90 | cevCesm8t1 |
cesm-8E1 | 91 | cevCesm8e1 |
frsm-2ct3 | 130 |
|
frsm-2t3 | 131 |
|
frsm-2e3 | 132 |
|
frsm-2hs2 | 133 | cevFrsm2hssi |
cesm-t3 | 140 | cevCesm1t3 |
cesm-e3 | 141 | cevCesm1e3 |
vism-8T1 | 150 |
|
vism-8E1 | 151 |
|
pxm-1 | 1000 | cevCpuPSM1Gbps |
pxm-t3e3 | 1001 | cevCpuPsm12t3e3 |
pxm-oc3 | 1002 | cevCpuPsm14oc3 |
pxm-oc12 | 1003 | cevCpuPsm11oc12 |
pxm-45 | 1100 | cevCpuPSM45Gbps |
rpm | 2000 | cevMGXRpm |
axsm1-Oc48 | 3000 | cevAxsm1Oc48 |
axsm4-Oc12 | 3001 | cevAxsm4Oc12 |
axsm8-Oc3 | 3002 | cevAxsm8Oc3 |
axsm16-Oc3 | 3003 | cevAxsm16Oc3 |
axsm16-T3E3 | 3004 | cevAxsm16T3E3 |
axsm2-Oc12 | 3005 | cevAxsm2oc12 |
axsm1-oc12-e | 3100 | cevEnhAxsm1oc12 |
axsm2-oc12-e | 3101 | cevEnhAxsm2oc12 |
axsm4-oc3-e | 3102 | cevEnhAxsm4oc3 |
axsm8-oc3-e | 3103 | cevEnhAxsm8oc3 |
axsm8-oc3-e | 3103 | cevEnhAxsm8oc3 |
axsm4-stm1-e | 3104 | cevEnhAxsm4stm1 |
axsm8-stm1-e | 3105 | cevEnhAxsm8stm1 |
axsm8-t3e3-e | 3106 | cevEnhAxsm8t3e3 |
axsm16-t3e3-e | 3107 | cevEnhAxsm16t3e3 |
axsm8-t1-e | 3108 | cevEnhAxsm8t1 |
axsm16-t1-e | 3109 | cevEnhAxsm16t1 |
axsm8-e1-e | 3110 | cevEnhAxsm8e1 |
axsm16-e1-e | 3111 | cevEnhAxsm16e1 |
Table D-4 lists the MGX 8220, MGX 8850, Release 1, and MGX 8850, Release 2 back cards supported in Release 10 of CWM and the bc_type value associated with each back card.
| Back Card Type | Value (bc_type) | Symbols in the MIB |
|---|---|---|
lm-ASC | (2), |
|
lm-DB15-4T1 | (16), |
|
lm-DB15-4E1 | (17), |
|
lm-BNC-4E1 | (18), |
|
lm-DB15-4T1-R | (19), |
|
lm-DB15-4E1-R | (20), |
|
lm-BNC-4E1-R | (21), |
|
lm-RJ48-8T1 | (22), | cevLmRj488t1 |
lm-RJ48-8E1 | (23), | cevLmRj488e1 |
lm-SMB-8E1 | (24), | cevLmSmb8e1 |
lm-RJ48-T3T1 | (25), |
|
lm-RJ48-E3E1 | (26), |
|
lm-RJ48-T3E1 | (27), |
|
lm-SMB-E3E1 | (28), |
|
lm-RJ48-E3T1 | (29), |
|
lm-SMB-T3E1 | (30), |
|
lm-T3-E3-D | (32), |
|
lm-T3-E3-B | (33), |
|
lm-155-SMF | (34), |
|
lm-155-UTP | (35), |
|
lm-RJ48-8T1-R | (48), | cevLmRj488t1R |
lm-RJ48-8E1-R | (49), | cevLmRj488e1R |
lm-SMB-8E1-R | (50), | cevLmSmb8e1R |
lm-SRM-3T3 | (51), |
|
lm-HS1-4X21 | (60), |
|
lm-HS1-2HSSI | (61), |
|
lm-HS1-4V35 | (62), |
|
lm-BNC-2T3 | (80), | cevLmBnc2t3 |
lm-BNC-2E3 | (81), | cevLmBnc2e3 |
lm-PXM-UI | (500), | cevLmPsmUI |
lm-SMFIR-1-622 | (501) | cevLmSmfIr1oc12 |
lm-SMFLR-1-622 | (502), | cevLmSmfLr1oc12 |
lm-SMFIR15-1-622 | (503), |
|
lm-SMFLR15-1-622 | (504), |
|
lm-MMF-4-155 | (505), | cevLmMmf4oc3 |
lm-SMFIR-4-155 | (506), | cevLmSmfIr4oc3 |
lm-SMFLR-4-155 | (507), | cevLmSmfLr4oc3 |
lm-BNC-3T3 | (510), |
|
lm-RJ45-FE | (511), |
|
lm-MMF-FE | (512), |
|
lm-MMF-FDDI | (513), |
|
lm-SMF-FDDI | (514), |
|
lm-RJ45-4E | (515), |
|
lm-DB15-4x21 | (601), | cevLmDb154x21 |
lm-SCSI2-2HSSI | (602), | cevLmScsi22hssi |
lm-S3-UI | (603), | cevLmS3Ui |
lm-MMF8-OC3 | (604), | cevLmMmf8oc3 |
lm-SMFIR8-OC3 | (605), | cevLmSmfIr8oc3 |
lm-SMFLR8-OC3 | (606), | cevLmSmfLr8oc3 |
lm-SMFIR-1OC48 | (607), | cevLmSmfIr1oc48 |
lm-SMFLR-1OC48 | (608), | cevLmSmfLr1oc48 |
lm-PSM-HD | (609), | cevLmPsmHD |
lm-SMB-8T3 | (610), | cevLmSmb8t3 |
lm-SMB-8E3 | (611), | cevLmSmb8e3 |
lm-SMB-4STM1 | (612), | cevLmSmb4stm1 |
lm-SMFIR-2-622 | (613), | cevLmSmfIr2oc12 |
lm-SMFLR-2-622 | (614), | cevLmSmfLr2oc12 |
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Thu Sep 28 16:13:18 PDT 2000
Copyright 1989-2000©Cisco Systems Inc.