cc/td/doc/product/rtrmgmt/cw2000/cfm/cfm10
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

Sample Solaris Installation Output

Sample Solaris Installation Output

This appendix provides examples of the following installation and uninstallation output listings for Solaris. The samples condense the long lists of installation files that are actually produced. Sample output listings are provided for the following:

Sample Solaris Express Installation Output

This following is an example of the output produced when you perform an express install of the CFM software on a Solaris workstation.

=========================================================================
=================- Content Flow Monitor Install Started -================
=========================================================================
Started :Wed Jan 12 11:11:43 EST 2000
Host    :SunOS leang 5.6 Generic_103640-28 sun4u sparc SUNW
Version :1.0
=========================================================================
 
============================================================
===============- System Requirements Check -================
============================================================
INFO:Checking UID... root, OK.
INFO:Checking your release... All components present.
INFO:Checking for existing product tree at /opt/CSCOcfm... None.
 
============================================================
=============- TCP/IP Address Resolution Check -============
============================================================
 
Here are the network-names defined for:leang
localhost
leang.cisco.com
 
INFO:Machine:"leang" resolves to  161.44.34.153  
 
INFO:Local address resolution -> Primary:files, Secondary:dns
 
============================================================
=================- TCP/IP Port Usage check -================
============================================================
INFO:This product uses these port numbers by default:
INFO:	[ 1] CFM Server:                4791/tcp
 
INFO:Now checking the system to see if these ports are already in use...
INFO:Checking port   4791 for CFM Server... Available.
 
============================================================
===================- CFM Install Summary -===================
============================================================
 
INFO:The following ports will be used:
 
INFO:	[ 1] CFM Server:                4791/tcp
 
INFO:Updating /etc/services as follows...
 
	cscocfmserver			  4791/tcp		# Cisco CFM Server
 
============================================================
================- Disk Space Usage check -==================
============================================================
INFO:For this product the default disk space requirements are:
	/opt      	      5000 K
 
INFO:Checking default disk space requirements... OK.
 
============================================================
================- Express Install Check -===================
============================================================
The Express Install takes all defaults and places the product
in /opt. No more questions will be asked.
 
Do you want the Express Install (y/n)? [Y] 
INFO:Installing product into /opt.
InstallBasePkgs
 
 
Processing package instance <CSCOcfm> from </auto/cwb-jumbo/build-images/nd/sol-1.0/12Jan00/CdImage>
 
Cisco Content Flow Monitor
(sparc) 1.0
 
Content Flow Monitor
(C) Copyright 1999,2000 Cisco Systems, Inc.
All rights reserved
 
Using </opt> as the package base directory.
## Processing package information.
## Processing system information.
## Verifying disk space requirements.
## Checking for conflicts with packages already installed.
## Checking for setuid/setgid programs.
 
Installing Cisco Content Flow Monitor as <CSCOcfm>
 
## Installing part 1 of 1.
/opt/CSCOcfm/CFM.properties
/opt/CSCOcfm/cfm
/opt/CSCOcfm/cfmMain.htm
/opt/CSCOcfm/classes/META-INF/MANIFEST.MF
/opt/CSCOcfm/classes/ND_AddDevice$1.class
/opt/CSCOcfm/classes/ND_AddDevice.class
/opt/CSCOcfm/classes/ND_AdvertisedAddress.class
/opt/CSCOcfm/classes/ND_AdvertisedAddressFolder.class
/opt/CSCOcfm/classes/ND_AffinityDist_FA.class
...
/opt/CSCOcfm/classes/ND_WildcardAffinityList.class
/opt/CSCOcfm/classes/NetworkDirector$1.class
/opt/CSCOcfm/classes/NetworkDirector$ActionComboListener.class
/opt/CSCOcfm/classes/NetworkDirector$ActionComboRenderer.class
/opt/CSCOcfm/classes/NetworkDirector$ND_TreeCellRenderer.class
/opt/CSCOcfm/classes/NetworkDirector.class
/opt/CSCOcfm/classes/com/cisco/nm/lib/snmp/futureapi/FutureIf.class
...
/opt/CSCOcfm/classes/com/cisco/nm/lib/snmp/lib/DatagramHandlerIf.class
...
/opt/CSCOcfm/classes/com/cisco/nm/lib/snmp/lib/timer/MyDispatcher.class
...
/opt/CSCOcfm/classes/com/cisco/nm/lib/snmp/util/IPSubidTree$IPSubid.class
...
/opt/CSCOcfm/exit.html
...
/opt/CSCOcfm/help/cfm/help.htm
...
/opt/CSCOcfm/images/16icon.bmp
...
/opt/CSCOcfm/install/CFM.lf
/opt/CSCOcfm/install/build-date
/opt/CSCOcfm/install/uninstall.sh
/opt/CSCOcfm/install/version
/opt/CSCOcfm/snmpinfo.dat
[ verifying class <cfm> ]
## Executing postinstall script.
 
Installation of <CSCOcfm> was successful.
 
INFO:Checking Installation.
INFO:Package CSCOcfm    installed OK. Verifying... OK.
 
============================================================
Integrating to CiscoWorks 2000 Server...
============================================================
 
To use this product, set your path to:
   /opt/CSCOcfm
 
To start server, run:
   cfm start
 
============================- Error Summary -============================
No Errors were encountered during installation.
 
=========================================================================
================- Content Flow Monitor Install Completed -===============
=========================================================================
Started : Wed Jan 12 11:11:43 EST 2000
Finished: Wed Jan 12 11:12:56 EST 2000
Please review /var/tmp/cisco_cfm_install.log for detailed results.
=========================================================================

Sample Solaris Uninstallation Output

This following is an example of the output produced when you perform an uninstall of the CFM software on a Solaris workstation.

=========================================================================
================- Content Flow Monitor Uninstall Tool -==================
=========================================================================
Started :Wed Jan 12 11:16:06 EST 2000
Host    :SunOS leang 5.6 Generic_103640-28 sun4u sparc SUNW
Version :1.0
=========================================================================
 
Continue uninstall of Content Flow Monitor? [n] 
INFO:Checking for Content Flow Monitor package on the system.
      Please wait...
INFO:The following Cisco Content Flow Monitor package is installed.
 
	CSCOcfm
 
INFO:Invoking pkgrm on Content Flow Monitor package...
 
INFO:Wed Jan 12 11:16:10 EST 2000, now removing CSCOcfm...
 
Removal of <CSCOcfm> was successful.
 
 
INFO:The following Cisco Content Flow Monitor
INFO:packages have been successful deleted from the system:
 
 CSCOcfm
 


hometocprevnextglossaryfeedbacksearchhelp
Posted: Sun Apr 2 12:25:15 PDT 2000
Copyright 1989 - 2000©Cisco Systems Inc.