|
|
21 October 1998
This document discusses the CiscoView 4.2(1) release and contains the following information:
| Small to Medium Business Products | Mid-Range Enterprise Products2 | High-End Enterprise Products |
|---|---|---|
Cisco 761, 762, 765, 766, 771, 772, 775, 776 | Catalyst switch models3 1200, 1400, 1600, 1601, 1700, 1800, 1900, 2100, 2600, 2800, 2820, 2900, 2900XL, 2926, 3000, 3100, 3200, 3900, 5002, and CPW2200 | Catalyst 5000, 5500, 5505, and 5509; and 8510 |
Cisco 1003, 1004, and 1005 | EtherSwitch Pro16, EPS2015, 1200, 1220, 1400, 1420 | Cisco 7000, 7010, 7204, 7206, 7505, 7507, 7513 routers |
Cisco 1601, 1602, 1603, 1604, 1605 | EtherSwitches: Pro16 and CPW16 | LS1010
|
Cisco 2501, 2502, 2503, 2504, 2505, 2507, 2509, 2510, 2511, 2512, 2513, 2514, 2515, 2516, 2520, 2521, 2522, 2523, 2524, and 2525 | Workgroup concentrators 1400 |
|
Cisco 3600 series (includes 3620 and 3640) and 3800 series | Fasthub 216T |
|
Cisco 4000 series4 (includes 4000, 4000-M, 4500, 4500-M, 4700, and 4700-M) |
| Cisco uBR7246 and uBR904 |
AS5200 Access Server | AS2509-RJ | AS5300 Access Server AS5800 Access Server |
Cisco 1501, 1502, 1503, 1516 |
|
|
Fasthub 300 and Fasthub 100+ Series |
|
|
EPS-500, EPS-1500, EPS2115, CPW-500, CPW-2115, and CPW-16 |
|
|
MWEB200 |
|
|
| Application | Description | OS | Cisco IOS | Device Support |
|---|---|---|---|---|
Threshold Manager | Monitors the availability and performance of Cisco devices | AIX 4.2.1 and 4.3 | Cisco IOS 11.1 or 11.2 with RMON events and alarms group support | Cisco 7000, 7010, 7505, 7507, and 7513; Cisco 4000, 4500, and 4700; Cisco 2501-2505, 2507, 2509-2525; Catalyst 1200 and 5000 |
StackMaker | Manages the device membership in a Cisco stack | Solaris 2.4, 2.5.1, and 2.6 | Cisco IOS 10.0 through 11.2 | Cisco 1500, 1600, 2600, 3600; Catalyst 1900, Catalyst 2820, Catalyst 2900XL; Fasthub 200 and Fasthub 300; AS5200 and AS5300; HP 10Base-T Hub-16M; MWEB200 |
Flash File System | Provides file copying and editing features for the 7000 Series routers | Solaris 2.4, 2.5.1, and 2.6 | Cisco IOS 10.0 through 11.2 | Cisco 7000, 7010, 7202, 7204, 7206, 7505, 7507, 7513 routers |
Cisco TN3270 Monitor | Monitors TN3270 capability embedded in Cisco devices with IBU feature set | Solaris 2.5.1 and 2.6 | Cisco IOS 11.0(13)BT, 11.2, or 11.3 with cip22-14 | Cisco 7000 and 7500 (with a CIP card) and Cisco 7200 (with ECPA card) |
| Device Package | Version |
|---|---|
1000.pkg | 4.0(1.2) |
1500.pkg | 4.0(1.2) |
1600.pkg | 4.0(5.0) |
2500.pkg | 4.0(4.0) |
2600.pkg | 4.0(3.0) |
3600.pkg | 4.0(11.0) |
3800.pkg | 4.0(1.02) |
4000.pkg | 4.0(3.1) |
700.pkg | 4.0(1.4) |
7000.pkg | 4.0(5.0) |
AS5200.pkg | 4.0(5.0) |
AS5300.pkg | 4.0(3.1) |
AS5800.pkg | 4.1(2.0) |
CPW10_100.pkg | 4.0(1.4) |
CPW1200.pkg | 4.0(1.4) |
CPW1220.pkg | 4.0(1.5) |
CPW1400.pkg | 4.0(1.4) |
CPW1420.pkg | 4.0(1.5) |
CPW16.pkg | 4.0(1.1) |
CPW2115.pkg | 4.0(1.1) |
CPW2200.pkg | 4.0(2.1) |
CPW316.pkg | 4.0(1.4) |
CPW500.pkg | 4.0(1.1) |
Cat116.pkg | 4.0(1.4) |
Cat1200.pkg | 4.0(1.4) |
Cat1600.pkg | 4.0(1.3) |
Cat1700.pkg | 4.0(1.4) |
Cat1800.pkg | 4.0(1.1) |
Cat1900.pkg | 4.0(2.0) |
Cat2100.pkg | 4.0(1.4) |
Cat216.pkg | 4.0(1.4) |
Cat2600.pkg | 4.0(1.3) |
Cat2800.pkg | 4.0(1.4) |
Cat2820.pkg | 4.0(2.1) |
Cat2900.pkg | 4.0(2.1) |
Cat2900XL.pkg | 4.0(2.0) |
Cat3000.pkg | 4.0(1.6) |
Cat3900.pkg | 4.0(1.5) |
Cat5000.pkg | 4.1(2.6) |
Cat5500.pkg | 4.1(2.6) |
Cat8510.pkg | 4.1(1.1) |
Cisco1516.pkg | 4.0(1.2) |
EPS2015.pkg | 4.0(1.1) |
LS1010.pkg | 4.0(2.3) |
MWEB200.pkg | 4.0(1.1) |
ubr7200.pkg | 4.0(1.1) |
ubr900.pkg | 4.0(1.0) |
TD_INTG.pkg | 4.1(1.6) |
TN3270/TN3270_AIX.pkg | 4.1(1.2) |
TN3270/TN3270_HPUX.pkg | 4.1(1.2) |
TN3270/TN3270_SOL.pkg | 4.1(1.2) |
WG_Concentrator.pkg | 4.0(1.3) |
stackmkr.pkg | 4.0(1.1) |
Threshold_AIX.pkg | 4.0(1.1.3) |
Threshold_HP10.pkg | 4.0(1.1.3) |
Threshold_WIN.pkg | 4.0(1.1.3) |
Threshold_SOL.pkg | 4.0(1.1.3) |
This section contains the latest Cisco IOS (Internetwork Operating System) software version information at the time of printing.
CiscoView supports Cisco IOS software Releases 10.0 through 11.3, with the following restrictions:
New devices and further specifics on Cisco IOS support will be updated as devices become supported. For the online release notes, refer to one of the following:
Documentation for CiscoView includes this release note, a CD-ROM installation booklet, an overview manual, and online help. The primary documentation for CiscoView is the online help. If you have documentation feedback, please email comments to:
bug-doc@cisco.com
The documents shipped with this release include:
Customer documentation can also be found on the Cisco Enterprise Customer Documentation CD or on CCO.
There are several ways to add (or incrementally install) support for new devices to CiscoView 4.2(1). Direct customers should refer to the section "Cisco Connection Online" at the end of this release note for information about accessing CCO. Partner-initiated customers should refer to the section "Partner Initiated Customer Accounts" (following).
You can add new devices to CiscoView from the CiscoView Upgrade Planner page on CCO at http://www.cisco.com/kobayashi/library/netmanage/cview/. On this page, go to the section "Download CiscoView Software Updates" and click "CiscoView 4.x Packages." From the "CiscoView 4.x Packages" page, you can download packages for all supported devices. For more information, refer to the "Downloading Device Packages" chapter in Getting Started with CiscoView. A quick reference version exists in the CiscoView CD Installation Instructions booklet.
In general, multiple devices within the same product family share a single device package. If you have a specific device in mind, look for the device package for the device's family. For example, use the 2500 package file for a Cisco 2512.
To determine if your particular device is supported, look at the readme for the device package (available on the same webpage listed in the previous section).
Do not use the pkgadd command for installation. Instead, use the setup.sh command. See the CiscoView CD Installation Instructions booklet for the most up-to-date version of install.
To get more information about the Partner Initiated Customer Accounts (PICA) program before accessing CCO for device package files, use the following URL:
http://www.cisco.com/acs/info/pica.html
You can also refer to the "Downloading Device Packages" chapter in Getting Started with CiscoView.
Table 4 (following) lists problems in CiscoView 4.1(1) that are fixed in CiscoView 4.2(1). Only the most serious problems resolved in CiscoView 4.2(1) are listed.
Applet and device package problems that have been fixed since the previous release are described in the respective applet and device package readme files. These readme files are available from the CiscoView Upgrade Planner:
http://www.cisco.com/kobayashi/library/netmanage/cview
CSCdi51665 | Users preferences such as timeout are not persistent across CiscoView sessions. |
CSCdi62739 | When saving new policies for a host, they will not match if IP is in use. |
CSCdj13160 | Changing from CiscoView 3.1(1) to CiscoView 4.1(1) leaves symbolic links in $SNMHOME/snm/agent. |
CSCdj38584 | Sometimes CiscoView cannot be configured due to missing fonts. |
CSCdj39055 | CiscoView does not support workgroup concentrator WS-X1434. |
CSCdj43438 | CiscoView does not properly convert the Timeticks SYNTAX. |
CSCdj50382 | A wrong instance might be used for subclass discovery. |
CSCdj58682 | Running CiscoView dumps core when a device package is incrementally installed. |
CSCdj59472 | Newly created rows might not be added to table. |
CSCdj60605 | CiscoView might fail to open a device if both the Catalyst 5000 and Yosemite card are set to the same community strings. |
CSCdj61077 | CiscoView package for the Cisco 7000 has typo for feip-f. |
CSCdj62691 | You might not be able to start the grapher on CiscoView integrated with EM 2. |
CSCdj62693 | The symbols patch does not work on Solaris. |
CSCdj64545 | TCL script interprets address as exponent ex. 1e550. |
CSCdj68522 | CiscoView port monitor default polling fails. |
CSCdj72051 | CiscoView is not able to work with AS5300. |
CSCdj75454 | Cisco 7000 package corrupts the Memory Used graph. |
CSCdj75485 | Need enhancement in engine for StackView support for AS5300. |
CSCdj81850 | CiscoView installation fails for Solaris SNM. |
CSCdj90331 | CV4.1(1) integration with HPOV/SNM fails. |
CSCdj92755 | CiscoView crashes when going to PVC Configuration menu. |
CSCdk03414 | Catalyst 5000 always uses default 6 sec snmp timeouts. |
CSCdk03853 | MIB files for the imported module SNMPV2-SMI are missing. |
CSCdk05042 | CiscoView installation may fail if $OV_BIN env. var. is defined on AI. |
CSCdk05800 | Change in the Wr.Com.Str When Opening a device does not change Op. |
CSCdk05801 | CV security patch is not invoked in AI. |
CSCdk08402 | Error message is displayed in em_service. |
CSCdk08741 | Error message displayed during installation. |
CSCdk08745 | Grapher is not working on CiscoView with EM 2.0 & SNM 2.2.3. |
CSCdk10191 | Wrong functionality during installation. |
CSCdk10541 | Default telephone text box accepting junk values. |
CSCdk11370 | Cancel option adds entries in phone book. |
If you cannot open a device in CiscoView 4.2(1), a message is displayed indicating that the device is unmanageable for one of the following reasons:
CiscoView is unable to open devicename because you do not have the appropriate device package installed on your machine. You can download the latest device package from the CiscoView Upgrade Planner:
http://www.cisco.com/kobayashi/library/netmanage/cviewThis section contains notes and restrictions that apply to the CiscoView 4.2(1) release.
Installation notes and caveats for CiscoView follow.
When a device package is installed, CiscoView updates HP OpenView with the device symbols and bitmaps.
If CiscoView does not appear in the Tools menu in Solstice Site Manager/Domain Manager, perform the following steps:
Step 1 Copy the file ciscoview.schema from the $NMSROOT/etc/cview/snm/struct directory to $SNMHOME/snm/struct, where NMSROOT is the CiscoView home directory (typically /opt/CSCOcv).
Step 2 Edit the $SNMHOME/snm/struct/ciscoview.schema file and replace the string "$NMSROOT" with your CiscoView home directory.
CiscoView 4.2(1) does not support an upgrade from CWSI 1.1. To upgrade CWSI to CiscoView 4.2(1), first upgrade CWSI 1.1 to CWSI 1.3 (or later) and then upgrade to CiscoView 4.2(1).
CiscoView 4.x is not compatible with CiscoWorks 2.x. To use CiscoView 4.x, remove CiscoWorks 2.x or upgrade to CiscoWorks 3.2.1 or later.
Some errors will be reported during the installation or incremental installation of device packages when MIBs are loaded into AIX NetView. For more information and workaround suggestions, refer to the following URLs:
http://www.cisco.com/public/mibs/app_notes/mib-compilers
or
ftp://ftp.cisco.com/pub/mibs/app_notes/mib-compilers
Update the path variable to include the path for the Sun Net Manager (SNM) binaries and also set the SNMHOME environment variable.
C Shell:
setenv SNMHOME /opt/SUNWconn/snm
set path=($path /opt/SUNWconn/snm/bin)
Bourne Shell:
SNMHOME=/opt/SUNWconn/snm
export SNMHOME
PATH=$PATH:/opt/SUNWconn/snm/bin
export PATH
The /opt/SUNWconn/snm directory is the default directory for SNM in Solaris. If SNM is installed elsewhere, please change the SNMHOME and path variables accordingly.
If you install CiscoView with all devices and integrate with SNM 2.2.3, if you start snm -i, errors are reported in the console window:
line 27: Unknown record name 'component.cisco-c8510' line 27: Cannot initialize field value component.cisco-c8510 failed in loading /opt/SUNWconn/snm/struct/Cat5500.schema
[CSCdk28924]
The SNM grapher might fail to display data. This bug requires SNM patches for SNM 2.2.3 and 2.3. You can download the patches from Sun Microsystem's official patch site:
ftp://zippy.telcom.arizona.edu/pub/snm/patches/Solaris2.x/SNM2.3/104018-02.tar.Z
If you still have problems graphing device data even after installing the appropriate patch, the problems might be fixed if you use the CiscoView menu option Edit>Create to register the device's IP address into the SNM database; enter the device's IP address into both the name field and the ip address field. [CSCdj01623]
The CiscoView installation on Solaris might fail if you do not install a Hewlett-Packard patch. This patch is required to install NNM 4.1 on Solaris 2.5.1 and must be installed before installing NNM 4.1. This patch is required to run a license server on Solaris 2.5.1. If your license server is on a different machine, this patch is not necessary.
Both patches consist of a tar file and a text file describing the patch. To obtain a patch
Step 1 Enter the following URL:
ftp://ovweb.external.hp.com/pub/cpe/patches/nnm/4.1x
Step 2 Click the appropriate links to get to your software patch.
Patch numbers are not available because HP consolidates the patches periodically to contain all previous fixes. Select the one related to Network Node Manager 4.1x by viewing the patch text files. If you have difficulty installing the patch, contact HP Service and Support.
CiscoView installation uses the Solaris pkgadd utility. When pkgadd finishes installing CiscoView, the screen shows that the installation was successful but does not quit. Type Q to exit the pkgadd utility.
line 46: syntax error line 49: syntax error failed in loading /opt/SUNWconn/snm/struct/Cat3900.schema
General notes and caveats follow. They are divided into five sections:
CiscoView does not support internationalization.
In high traffic situations, you might experience timeouts. To increase the timeout period, select Options>Properties from the CiscoView menu and change the value for the Timeout field.
You should not reduce the physical view polling interval below (retries*timeout), especially if you experience timeouts; this can exhaust resources on Windows and result in a general error.
When CiscoView is integrated with EM 2.0, if you start CiscoView from the glyph menu for any device the EM displays a message in the stdout before launching CiscoView. The displayed message shows the public and private community strings for the device. [CSCdk13867]
On UNIX platforms, for this release, use the middle mouse button to drag. Only certain devices (such as the CAT1200, CAT1600, CAT5000, CPW16) have defined their ports for dragging across devices.
When CiscoView is invoked from an NNM, whenever you open a device, one or more command windows momentarily pop up then disappear. [CSCdk14010]
When CiscoView is using an AXIS device package, if the AXIS agent cannot process packets sent by CiscoView (generating tooBig errors), CiscoView core dumps. [CSCdk24025]
If a switch is configured as two or more domains, HP OpenView discovery might not work properly and might discover only one of the domains. If this occurs, use CiscoView to manage the domain directly rather than launching the switch from the map.
With HP OpenView, the grapher does not graph with v2c agents, especially 64-bit counters values. The HP OpenView bug ID is 4701401398. To work around this problem, use the Data Collector to collect and to then graph the desired data. [CSCdk08824]
When you use CiscoView with Enterprise Manager 2.0, sometimes the em_discover application terminates abnormally. To prevent this problem, you must have less than 750 entries in $EM_HOME/config/discover.conf. [CSCdj56566]
Certain SNMP traps are not integrated into SUN's Enterprise Manager 2.0. Instead, the traps show up as generic traps with names such as "internetTrap" or "enterpriseSpecificTrap." [CSCdk18129]
If you install CiscoView with all devices and integrate with SNM 2.2.3, if you start snm -i, errors are reported in the console window:
line 27: Unknown record name 'component.cisco-c8510' line 27: Cannot initialize field value component.cisco-c8510 failed in loading /opt/SUNWconn/snm/struct/Cat5500.schema
[CSCdk28924]
If you are loading .schema files into SNM, while loading the CISCO-STACK-MIB.schema file, you might see errors such as the following:
line yyy: Duplicate attribute name <attrname> line xxx: Duplicate error code <errcod> failed in loading /opt/SUNWconn/snm/agents/CISCO-STACK-MIB.schema.
You can ignore these messages. [CSCdk45034]
MWEB200 is not detected by SNMPc autodiscovery. [CSCdk26676]
Popup menus might be out of focus. To correct the focus, move your pointer out of the window and back into the menu.
CiscoView might fail to print to a LaserJet III printer, especially in the "LaserJet" format, because of this printer's limited memory.
Internal Debugging---When the StackMaker Debug option is set to On, debug messages print to the StackMaker Debug Log file. The default is Off. The StackMaker Debug Log file stores messages that are useful in troubleshooting problems. This log file is /tmp/.smDebugLog.
Internal Debugging---When the StackMaker Debug SNMP option is set to On, SNMP debug messages print to the StackMaker Debug Log file on the UNIX platform. The messages show the SNMP packets that have been sent and received. The default is Off. The StackMaker Debug Log file stores messages that are useful in troubleshooting problems. This log file is /tmp/.smDebugLog.
Log File from Apply Operations---The StackMaker log file stores the results of a saved stack configuration (Actions>Apply Stack Configuration). The log file is /tmp/stackmkr/sm.log. When the log file exceeds 1 MB, it automatically resets to 0 bytes.
When StackMaker runs on Catalyst 1900 devices, some debug output is printed to the console. You can ignore this output.
You might get error messages when invoking StackView for a device, particularly if you just changed the "seed" device or if you previously opened and closed the stack. If you get error messages when invoking StackView, exit the current CiscoView session and launch a new CiscoView session. [CSCdk12100]
If you have an AS5200, AS5300, Catalyst 216, and Cisco 3640 in a stack, and you are using CiscoView in CiscoWorks Windows, LS3 Setup might crash with a Dr. Watson for NT error with the error message "wish.exe exception access violation." This crash occurs only if you click any item under Connection Info twice and if the Catalyst 216 is the seed device. [CSCdk23763]
Some agents, most notably the Catalyst switches, impose a limit on the number of alarm and event entries that can be created. Applying a large number of thresholds to these devices will likely fail. In this case, some alarm entries might be successfully created but their associated event entries are not. These failed creations are marked as Failed in the Current Threshold Settings pane. If you attempt to delete those settings, Threshold Manager reports that the deletion failed (because it cannot delete nonexistent event entries.) In this case, you can ignore the error message and can verify that the deletion occurred by retrieving the threshold settings after the deletion.
When you use the Switch Zoom menu (if TrafficDirector is installed) from CiscoView to view multiple switch ports, the default configuration for the Catalyst 1200 is Statistics, Short-Term history, Long-Term history, and Host group. To see the Short-Term or Long-Term history from Traffic Monitor, use the Domain Manager to configure the Short-Term and Long-Term groups manually or use Segment Zoom to view the port first.
When using the Segment Zoom menu from CiscoView to view the port segment, the default configuration for the Catalyst 1200 is the Statistics, Short-Term history, Long-Term history and Host group. For the Catalyst 5000 it is Statistics, Short-Term history, and Long-Term history.
If you get the "Error: Entry or Group not present in Agent" message when starting Segment Zoom, Switch Zoom, or Data Capture, the write community string might not match the device. If the community string matches but the problem still occurs, use the CiscoView Configure Device menu to see whether the RMON capability is enabled.
If you launch Switch/Port Zoom from CiscoView and then delete one of the RMON Agents using TrafficDirector, you must relaunch CiscoView before launching Switch/Port Zoom again.
If you see "IP address is not set in sysIpAddr MIB variable," the Catalyst 1200 SNMP agent does not store the correct IP address in the sysIpAddr MIB variable. You must use CiscoView to correct this error. Select Configure>Device, enter the correct IP address in the corresponding field, and click Modify.
TrafficDirector 3.3 cannot be launched for interfaces with ifIndex values greater than 1000.
Version 4.0(1.4) of the Cat1700.pkg device package does not work properly if either of the following device packages are installed: Cat1900.pkg, Version 4.0(2.0); or Cat2820.pkg, Version 4.0(2.1). [CSCdk48245]
The device agent does not update the IP address table of MIB-II properly and does not reflect the correct IP address information of all the device interfaces. You cannot view the correct IP address information of the device by selecting Device>Configure>IP Address Table.
You cannot create new static entries for IP Route Table and ARP Table through CiscoView.
In the interface configuration (Port>Config>Interface), modifying the IP parameters always displays an error message, but the modification is successful.
You cannot change the bridge type of the FDDI port to sr-only or srt.
You cannot change the bridge type of the Token Ring port to srtb or tb-only.
The system time configuration is not included as part of device configuration.
CPW1200, CPW1220, CPW1400, CPW1420, Catalyst 1900, Catalyst 2100, Catalyst 2800, and Catalyst 2820---The General Bridge window shows the bridge information for VLAN1 only. Bridge information for other VLANs is not available.
CPW1200, CPW1220, CPW1400, CPW1420, Catalyst 1900, Catalyst 2100, Catalyst 2800, and Catalyst 2820---The Spanning Tree Protocol window for switched ports is available for ports in VLAN1 only. This window does not show valid information for ports that are not in VLAN1.
VLAN colors are not displayed in CiscoView for a Catalyst 1900 with a VLAN is highlighted in VLAN Director. [CSCdk40128]
If you launch a Catalyst 1924 with Firmware V8.00.04(03), you cannot access the Port Zoom or Switch Zoom applications from Rmon Options. [CSCdk24862]
On the front panel display of the device, the Connect and Disabled LEDs on FDDI modules do not reflect the appropriate status.
The Configure>Module option is supported only for one module type, even though it can be invoked for multiple module types.
There is a dependency between the CPW1420 and Catalyst 2820. The CPW1420 device package will not run unless the Catalyst 2820 package is installed. [CSCdj64496]
To delete an entry from the Set Managers configuration, enter an IP address of 0.0.0.0. The agent on the devices do not accept a blank entry for an IP address. [CSCdj03444]
To delete an entry from the Set Managers configuration, enter a blank field. The IP address of 0.0.0.0 does not remove the entry from the Set Manager Table.
The Catalyst 2600 device package contains two versions of the Enterprise MIBs for the Catalyst 2600 switch:
If you are using a MIB browser tool, you will see the MIB variables defined in each of the above files, under different branches, at the same time, although any particular Catalyst 2600 switch will respond to queries on only one of the MIBs, based upon the release of software in the device. Cisco recommends that you upgrade your Catalyst 2600 switches to version 2.2.1 or later.
If the number of the embedded RMON agent is over 50, you cannot create any new embedded RMON agent group for the new port. Use the Domain Manager to uninstall the agent group from the unused port to free the memory resource.
If you launch Switch/Port Zoom (if TrafficDirector is installed) from CiscoView and then delete one of the RMON Agents using TrafficDirector, you must relaunch CiscoView before launching Switch/Port Zoom again.
TrafficDirector 3.3 cannot be launched for interfaces with ifIndex values greater than 1000.
When multiple ports are selected, the Port>Configure window does not display the Broadcast Suppression category. This category is available only for single port selection.
When you enable port security administration on a port, there may be timeouts. If this happens, increase the SNMP timeout value to approximately 10 seconds.
The WS-X2901 module shows the speed LED lit only when the speed is configured as 100 Mbps and the port is connected.
The Port Utilization tool has been removed from the Tools menu and is now available only on a per module basis on the Config>Module menu.
CiscoView is missing the Rmon Option menu for the Catalyst 2900XL, so there is no access to Traffic Director, Switch Zoom, Port Zoom. [CSCdk15743]
When you access a stack with six or more devices, there might be some significant performance problems. You can improve performance by increasing the SNMP timeout settings.
The Catalyst 3000 software does not support RMON on either a stack or an ATM port.
You might notice timeout messages and SNMP Set Failed messages when using the EtherChannel Configuration tool. If this happens, increase the SNMP timeout values for better performance.
If you are running version 2.0(1) of the Catalyst 3000 software, you will not be able to drag a port to a VLAN that does not already have ports assigned to it. You can fix this problem by upgrading to a later release of Catalyst 3000 software.
If you are running version 2.0(1) of the Catalyst 3000 software, changes to Full/Half Duplex settings will not always be reported correctly. You can fix this problem by upgrading to a later release of Catalyst 3000 software.
If you are running version 2.0(1) of the Catalyst 3000 software, the SAID value entered when creating a new VLAN will be redisplayed as a different value. However, the VLAN will have been created with the SAID value you specified. You can fix this problem by upgrading to a later release of Catalyst 3000 software.
The Domain Configuration and EtherChannel Configuration tools are not supported on Windows 95.
Because of restrictions in the Catalyst 3000 software, the WS-X3006B is displayed in CiscoView as a WS-X3006A.
If you launch Switch/Port Zoom (if TrafficDirector is installed) from CiscoView and then delete one of the RMON Agents using TrafficDirector, you must relaunch CiscoView before attempting to launch Switch/Port Zoom again.
CiscoView does not show the rear view of the Catalyst 3900 box.
When you attempt to drag port(s) to drop into one of the CRFs in the VLAN table, CiscoView might exit with an error. To work around this problem, first select the ports of interest, then bring the focus back to the VLAN Table window. Drag the selected port(s) and drop them into the desired CRF.
The Configure... option under the Bridge Configuration category allows you to view a current configuration only. It reports an error when you attempt to configure new values for any parameter.
The Threshold Manager and TrafficDirector applications have not been fully tested with the Catalyst 3900.
If you have a Catalyst 3900 device package installed, you might receive error messages during MIB integration of CiscoWorks Windows with HP Openview NNM 5.02. You might be unable to load certain MIBs. [CSCdk10109]
When a Catalyst 5500 is open in CiscoView, any changes you make to the device's community strings do not take effect. To work around this problem, run xnmsmpconf and set the global default "set" value to "private." [CSCdk14013]
When a Catalyst 5000 is open in CiscoView, if you change the community strings, the changes will become the default community strings used by CiscoView for devices with unknown community strings. To work around this problem, close and reopen CiscoView, then change the default community strings by selecting Options>Properties from the menu. [CSCdk14111]
ATM, FDDI, and CDDI do not support Broadcast Suppression.
In machines that do not have a /tftpboot directory (such as a PC), an error is displayed whenever the Upload/Download feature is invoked on a Catalyst 5000 module.
Do not use the Grapher in the CiscoView Monitor 10BaseT Group Switching Ethernet window. Use the Monitor or TrafficDirector tools (if TrafficDirector is installed) to see graphical views of the selected repeater ports.
When you use the Switch Zoom menu (if TrafficDirector is installed) from CiscoView to view multiple switch ports, the default configuration for the Catalyst 5000 is to configure Statistics only. To see the Short-Term or Long-Term history from Traffic Monitor, use the Domain Manager to configure the Short-Term and Long-Term groups manually or use Segment Zoom to view the port first.
When you use the Segment Zoom menu from CiscoView to view the port segment, the default configuration for the Catalyst 5000 is Statistics, Short-Term history, and Long-Term history.
If you see the message "Error: Entry or Group not present in Agent" when starting Segment Zoom, Switch Zoom, or Data Capture, the write community string may not match the device. If the community string matches but the problem still occurs, use the CiscoView Configure Device menu to see whether the RMON capability is enabled.
When you select the repeater module port on a Catalyst 5000, it always uses the first port of the selected segment to create the RMON agent group.
If all Catalyst 5500 slots are populated with modules and you experience timeouts, increase the SNMP timeout value to 15 seconds.
The WS-X5213 and WS-X5213A modules show the 100 Mbps speed LED lit only if the speed is configured at 100 Mbps and the port is connected.
Opening the FDDI/Ethernet Bridge category under Configure>Device can display an "unknown error." This is because of a problem with the device software.
If a general error (genErr) is displayed when you change vlanPortIslStatus, the selected port might not support ISL.
The values of ifAdminStatus and ifLinkUpDownEnable cannot be changed on an ATM port.
Port duplex settings cannot be changed on ATM and FDDI ports.
The value portSpanTreeFastStart cannot be changed on ATM and FDDI ports.
Configuring ports to unsupported speeds returns a general error (genErr). This is because of a problem in the device software.
If you run CiscoView from CWSI, and CWSI is integrated with SNM 2.3 on Solaris 2.5.1, if you try to disable all ports on different modules at once on a Catalyst 5500, the LANE module resets.
This problem occurs with the ATM LANE module WS-X5158. This problem occurs only on Catalyst 5500s with LECS functions.
To avoid this problem, disable ports individually. [CSCdk40179]
The CPW 1200/1400 and Cat 2100/2800 devices do not support the CDP and CGMP protocols. The CiscoView dialogs for these will return errors.
When the user enters values for the read-only, write-only, and read-writeId with the Command Line Interface (CLI) commands, these values must match. A mismatch results in noSuchName or timeout errors. To avoid these error conditions, use identical community strings in CiscoView and corresponding agents.
When multiple ports of different types are selected, Port>Config may show duplicate categories.
The following firmware versions must be used in the switches:
| Switch | Firmware Version |
|---|---|
Catalyst 1700 | 1.38 or later |
Catalyst 1900 and 2820 | 3.63 or later |
Catalyst 2100 and 2800 | 3.63 or later |
EtherSwitch 10/100 | 1.38 or later |
EtherSwitch 1220 and 1400 | 3.63 or later |
Grand Junction FastSwitch 10/100 | 1.37 or later |
Grand Junction FastSwitch 2100 and 2800 | 3.62 or later |
FastHub 300 Series | 1.12 or later |
When launching TrafficDirector 4.1.3 from CiscoView, make sure that /usr/lib is included at the start of the LD_LIBRARY_PATH environment variable. A segmentation fault may occur if it is not included.
If you launch Switch/Port Zoom from CiscoView and then delete one of the RMON Agents using TrafficDirector, you must relaunch CiscoView before attempting to launch Switch/Port Zoom again.
TrafficDirector 3.3 cannot be launched for interfaces with ifIndex values greater than 1000.
In the channel_modem view, CiscoView does not properly reflect the status of the T1/E1 channel_ports (timeslots) that have been configured for channel-group. This is a Cisco IOS software problem.
The hot swap feature is not available for stacked Cisco 3600 series routers.
Whenever the async/sync port configuration is changed, you must reopen the stack for CiscoView to update the async/sync port status. However, the hot swap feature for the async/sync ports is supported for individual Cisco 3600 series routers.
Also, whenever the async/sync port configuration is changed in a 16/32 port asynchronous network module, you must reopen the stack to obtain the latest state. However, the hot swap feature for the async/sync ports is supported for individual Cisco 3600 series routers.
The Logical View and Channel Modem Mapping view are not available for stacked Cisco 3600 series routers. This support is scheduled for a future release. However, Logical View is available on individual or stacked Cisco 3600 routers if a digital modem carrier card and a T1/ E1 card is present.
The fix for defect CSCdi69480 (PRI/E1 interfaces missing in cardIfIndex table) is integrated into Cisco IOS Release 011.001(007) and later. The Cisco 3600 4.0(6.1) device package incorporates the fix and may not work properly with Cisco 3600 series routers running Cisco IOS versions below 011.001(007).
To configure an LECS address for LS1010 from CiscoView, ServiceId needs to be the following: 10.1.3.6.1.4.1.353.1.5.1.<Index>, where Index is the row differentiator for configuring multiple LECS addresses. Index is an integer.
By default, CiscoView 3.1(1) displays two power supplies for a Cisco 7000 router running Cisco IOS Release 10.2 and earlier. With Cisco IOS Release 10.3 and later, power supplies are displayed based on ciscoEnvMonSupplyState values.
Because of the way a master CiscoView contents file is used by the software when multiple CiscoView device package help files are present, the list of files to include when setting up a customized find operation contains multiple items called CiscoView. [CSCdj62089]
There is a problem with the online help viewer, HyperHelp, intermittently displaying the Help topic window when opening Help>Contents.
When you first open a help topic using Help>Contents and click the Back button, the HyperHelp viewer might display a blank window. This is a HyperHelp bug. [CSCdi04758]
While browsing Help pages, you might be unable to open a help topic and you might see an error message such as "cannot open file filename." If this occurs, it could be that there is a low limit on the number of files that can be opened by a specific process.
To work around this problem, increase the kernel configuration parameter "number of open file descriptors per process" to approximately 90 or more. [CSCdk49538]
Cisco Connection Online (CCO) is Cisco Systems' primary, real-time support channel. Maintenance customers and partners can self-register on CCO to obtain additional information and services.
Available 24 hours a day, 7 days a week, CCO provides a wealth of standard and value-added services to Cisco's customers and business partners. CCO services include product information, product documentation, software updates, release notes, technical tips, the Bug Navigator, configuration notes, brochures, descriptions of service offerings, and download access to public and authorized files.
CCO serves a wide variety of users through two interfaces that are updated and enhanced simultaneously: a character-based version and a multimedia version that resides on the World Wide Web (WWW). The character-based CCO supports Zmodem, Kermit, Xmodem, FTP, and Internet e-mail, and it is excellent for quick access to information over lower bandwidths. The WWW version of CCO provides richly formatted documents with photographs, figures, graphics, and video, as well as hyperlinks to related information.
You can access CCO in the following ways:
For a copy of CCO's Frequently Asked Questions (FAQ), contact cco-help@cisco.com. For additional information, contact cco-team@cisco.com.
Cisco documentation and additional literature are available in a CD-ROM package, which ships with your product. The Documentation CD-ROM, a member of the Cisco Connection Family, is updated monthly. Therefore, it might be more current than printed documentation. To order additional copies of the Documentation CD-ROM, contact your local sales representative or call customer service. The CD-ROM package is available as a single package or as an annual subscription. You can also access Cisco documentation on the World Wide Web at http://www.cisco.com, http://www-china.cisco.com, or http://www-europe.cisco.com.
If you are reading Cisco product documentation on the World Wide Web, you can submit comments electronically. Click Feedback in the toolbar and select Documentation. After you complete the form, click Submit to send it to Cisco. We appreciate your comments.
|
|