cc/td/doc/product/mels/cm1500
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

Technical Data

Technical Data

The chapter details the hardware and software specifications of the NEMI and the SNMP protocols for the wavelength channel modules (WCMs).

NEMI Hardware

The NEMI consists of the following:

NEMI Software

The NEMI software consists of the following:

Software Upgrade

Reprogramming of the Flash memory is available through an Ethernet connection or serial port connection. See the "Transferring a System Update" section.

External Modem Configuration

For dial-in and dial-out use, you have to set up an external modem using AT (Attention) commands on your modem. The settings described in Table 8-1 affect modem performance when calls start and end.


Table 8-1: External Modem Settings
Command Description

E0

Command echo OFF

Q

Result codes are reported

V1

Verbose ON

S0=1

Answer on first ring

&C1

DCD is on after connect only

&S0

DSR is always on

DTR on/off resets modem (depends on manufacturer)

The modem should be connected by a cable that can transmit all the signals listed in Table 8-2 to the NEMI DB9 serial connector.


Table 8-2: DB9 Serial Connector Signals
Signal Description Pin

RxD

Receive data

2

TxD

Transmit data

3

DTR

Data terminal ready

4

GND

Signal ground

5

DSR

Data set ready

6

RTS

Request To Send

7

CTS

Clear To Send

8

RI

Ring indicator

9

SNMP Features of WCMs

When a WCM is installed, the data marked "Automatic Read" (Table 8-3 and Table 8-4) is automatically supplied to the NEMI.


Table 8-3: Configuration Data
Feature SNMP Management

Serial no.

Automatic Read

Channel location

Automatic Read

Clock (yes/no)

Automatic Read

Cooled laser (yes/no)

Automatic Read

Power supply available (yes/no)

Automatic Read

Fan available (yes/no)

Automatic Read


Table 8-4: Monitoring of Technical Operation Conditions
Feature SNMP Management

Power supply failure (yes/no)

Automatic Read

Fan failure (yes/no)

Automatic Read

Environmental temperature (of converter card)

Automatic Read

Laser temperature (stabilized laser only)

Automatic Read

Laser current (stabilized laser only)

Automatic Read

Hardware error

Automatic Read

Configuration data for the WCM receivers and transmitters can be manually read (Table 8-5). Table 8-6 shows the RSM status.


Table 8-5: WCM Receivers and Transmitters
Receiver or Transmitter Feature SNMP Management

Local receiver

Loss of signal

Read

Remote receiver

Status of laser (on/off)

Read

Local transmitter

Loss of signal

Read

Remote transmitter

Status of laser (on/off)

Read

Loop status

Local/remote/both/none

Read


Table 8-6: RSM Status
Feature SNMP Management

Status (line A/lineB/lock)

Read


hometocprevnextglossaryfeedbacksearchhelp
Posted: Tue Jun 6 18:34:31 PDT 2000