This chapter describes problems that could occur with the Cisco 1548M Micro Switch 10/100, possible reasons for the problems, and possible steps to take to solve the problems. The problems are grouped into logical states from startup to a state where the switch is up and running.
Table 4-1 lists problems that could occur after you connect the power cord for the first time.
| Symptom | Possible Problem | Possible Solutions |
|---|---|---|
Power cord is connected to switch, but all LEDs, including the PWR LED, are off. | No power to switch. |
|
Table 4-2 lists problems that could occur after the switch powers up for the first time.
| Symptom | Possible Problems | Possible Solutions |
|---|---|---|
No link to a network device. (The front and back panel LEDs for the connecting port are off.) |
| Perform the following tasks in the following order:
|
|
|
|
As described in the "Using POST to Pretest the Switch Operation" section, the switch runs eight tests each time it is powered up. This section provides information about fatal and nonfatal POST failures and recovery procedures.
If your switch has a fatal failure, the POWER LED is amber, and a port LED is blinking green. The switch is not operational, but the blinking port LED indicates which test failed. Contact your Cisco representative or reseller for support.
If a nonfatal failure occurs, the POWER LED is amber, and the switch is still operational and can forward packets, but it might not operate optimally. A POST failure message on the switch diagnostic console, such as the one in Figure 4-1, is displayed. In this example, the message indicates the second POST test (nonfatal---UART test) failed. Table 4-3 describes the individual tests and their associated LEDs.
For information on displaying POST results from the switch diagnostic console, see the "Starting Up the Switch and Displaying the POST Results" section.
------ Performing the Power-On Self Test (POST) ------ EPROM Checksum Test ....................... PASS UART Channel Int. Loopback Test ........... FAIL System SDRAM Test ......................... PASS CPU Self Test ............................. PASS GT64111 Internal & DRAM Access Test ....... PASS GT48004 Internal & DRAM Access Test ....... PASS PHY Access Test ........................... PASS System Image Checksum Test ................ PASS ------------ Power-On Self Test Completed ------------
| Port LEDs | Test |
|---|---|
4 | Fatal---Boot code test. Checks the integrity of the checksum for the boot code. Switch is not operational. Contact your Cisco representative or reseller for support. |
3 | Nonfatal---UART test. Checks the internal loop-back function for the UART channel. |
2 | Fatal---SDRAM test. Checks the functionality of the SDRAM. Switch is not operational. Contact your Cisco representative or reseller for support. |
1 | Fatal---CPU self test. Checks the functionality of the CPU. |
8 | Fatal---GT-64111 test. Checks the functionality of the GT-64111 (PCI bridge). Contact your Cisco representative or reseller for support. |
7 | Fatal---GT-48004A test. Checks the functionality of the GT-48004A (switch IC). Contact your Cisco representative or reseller for support. |
6 | Fatal---PHY test. Checks the functionality of the PHY (transceiver). Contact your Cisco representative or reseller for support. |
5 | Fatal---System image test. Checks if the integrity of the system code, which relies on the Flash ROM, is correct or not. Switch is not operational. Contact your Cisco representative or reseller for support. |
Table 4-4 lists problems that could occur after the switch has been up and running for a while.
| Symptom | Possible Problems | Possible Solutions |
|---|---|---|
Connection to a network device is lost. (The front and back panel LEDs for the connecting port are off.) |
|
|
|
| |
|
| |
The throughput of data via the connection is less than what you expected. |
|
|
|
|
|
The diagnostic console is a menu-driven interface that you can use to perform the following tasks:
To display the diagnostic console, follow these steps:
Step 1 Connect a management station with terminal emulation software (such as ProComm or Reflection) supporting the XMODEM Protocol to the switch console port.
Step 2 Start up your emulation program.
Step 3 Set the line speed on the emulation software to 9600 baud.
Step 4 Unplug the power cord from the back of the switch.
Step 5 Power up the switch.
Step 6 Within 5 seconds after power up, press Ctrl-x three times:
^x ^x ^x
A display such as the one in Figure 4-2 appears.
Cisco Systems Diagnostic Console Copyright (c) Cisco Systems, Inc. 1999 All rights reserved. Model: 1548 Micro Switch 10/100 Boot Firmware Version: 1.00.00 Ethernet Address: 00-E0-1E-7E-B4-40 ------------------------------------------------- Press enter to continue.
The firmware version used by the switch is displayed in the Boot firmware version field.
The Diagnostic Console - Systems Engineering Menu (Figure 4-3) provides options from which you can troubleshoot firmware problems and then bring up the firmware as usual.
To display this menu, press any key from the Diagnostic Console Display (Figure 4-2).
Diagnostic Console - Systems Engineering Boot Firmware Version: 1.00.00 [C] Continue with standard system start up [U] Upgrade operation firmware (XMODEM) [B] Change the baud rate of the main console RS232 interface [S] System debug interface Enter Selection:
The firmware version used by the switch is displayed in the Boot firmware version field.
To display the POST results, as shown in Figure 4-1, follow these steps;
Step 1 Enter C (the Continue with standard system start up option) from the Diagnostic Console - Systems Engineering Menu.
The following prompt is displayed:
Please reset your terminal application's baud rate to (9600, 8, 1, N) now before you leave the recovery procedure. Press any key to continue.
Step 2 Reset the line speed on the emulation software to 9600 baud, 8 data bits, 1 stop bit, and no parity.
Step 3 Press any key to begin POST.
Switch firmware can be corrupted during an upgrade, and it is possible to download the wrong file. In both cases, the switch does not pass POST, and there is no connectivity.
From the diagnostic console, you can download the upgrade file from a management station to the switch via the XMODEM protocol. The procedure for downloading the firmware via XMODEM is largely dependent on the terminal emulation software you are using.
To download the switch firmware via the XMODEM protocol, follow these step:
Step 1 Copy the switch firmware from Cisco Connection Online (CCO) to a temporary area on your management station.
New firmware releases can be downloaded from CCO, the Cisco Systems' customer web site available at the following URLs: www.cisco.com, www-china.cisco.com, and www-europe.cisco.com.
Step 2 Connect the management station with terminal emulation software (such as ProComm or Reflection) supporting the XMODEM Protocol to the switch console port.
Step 3 Start up your emulation program.
Step 4 Set the line speed on the emulation software to 9600 baud.
Step 5 Display the diagnostic console as described in the "Accessing the Diagnostic Console" section and "Using the Diagnostic Console - Systems Engineering Menu" section.
Step 6 Enter B (the Change the baud rate of main console RS232 interface option) from the Diagnostic Console - Systems Engineering Menu to temporarily change the baud rate of the switch console port.
The following prompt is displayed:
Change the baud rate of the main console RS232 interface to one of the following values. Change the setting of your terminal application to match the value you selected. [1] 9600 bps [2] 19200 bps [3] 38400 bps [4] 57600 bps Enter Selection:
Step 7 Select a baud rate for the switch console port by entering 1, 2, 3, or 4.
Step 8 Change the baud rate of the management station to match the baud rate you selected for the switch console port.
Step 9 From your emulation session, locate the switch upgrade file and use the appropriate command to transfer the file to the switch.
Step 10 Enter U (the Upgrade operation firmware (XMODEM) option) from the Diagnostic Console - Systems Engineering Menu.
The following prompt is displayed:
The XMODEM protocol will be used to perform this firmware upgrade. The user must initiate an XMODEM file transfer from the terminal side using an appropriate terminal application specific command. Do you wish to continue with the download process? [Y]es or [N]o:
Entering N redisplays the Diagnostic Console - Systems Engineering Menu.
Step 11 Enter Y, and press Return.
The following prompt is displayed:
Starting XMODEM download...
Is a prompt displayed when download is completed?
Step 12 When the download is completed, the follow prompt is displayed:
XMODEM download completed. Download Buffer Checksum Test..............Pass Upgrade system image to Flash memory.......Pass Press any key to continue.
Pressing any key displays the Diagnostic Console - Systems Engineering Menu.
| Caution If you interrupt the transfer by turning the switch off and on, the firmware could get corrupted. |
If you have forgotten or lost the switch password, you can use the diagnostic console to overwrite the password with a new password.
To recover from a lost or forgotten password, follow these steps:
Step 1 Connect a management station with terminal emulation software (such as ProComm or Reflection) supporting the XMODEM Protocol to the switch console port.
Step 2 Start up your emulation program.
Step 3 Set the line speed on the emulation software to 9600 baud.
Step 4 You can either:
(a) Unplug the power cord from the back of the switch and then power up the switch.
or
(a) Display the diagnostic console as described in the "Accessing the Diagnostic Console" section and "Using the Diagnostic Console - Systems Engineering Menu" section.
(b) Enter C (the Continue with standard system start up option) from the Diagnostic Console - Systems Engineering Menu.
After POST completes, the following prompt is displayed:
If a password has already been assigned, the following prompt is displayed:
Clear passwords? [Y]es or [N]o:
After you have selected Y or N, the following prompt is displayed if no IP information has been assigned to the switch:
Continue with configuration dialog? [Y]es or [N]o:
The Diagnostic Console - System Debug Interface Menu (Figure 4-4) provides system options from which you can reset the console port or the entire switch to the factory defaults. You can also use this menu to display the factory-installed management interface password.
To display this menu, enter S (the System debug interface option) from the Diagnostic Console - Systems Engineering Menu.
Diagnostic Console - System Debug Interface [M] Memory I/O [F] Return system to factory defaults [R] Reset main console RS232 interface to 9600,8,1,N (NVRAM Setting) [X] Exit to Previous Menu Enter Selection:
There can be times when you need the diagnostic console even though the firmware is valid. This could happen, for example, if the switch configuration prevents the firmware from executing properly and you cannot display the management interfaces.
To reset to the switch to the factory defaults, follow these steps:
Step 1 Enter F (the Return system to factory defaults option) from the Diagnostic Console - System Debug Interface Menu.
The following prompt is displayed:
Return system to factory defaults? [Y]es or [N]o:
Entering N redisplays the Diagnostic Console - System Debug Interface Menu.
Step 2 Enter Y.
To reset to the switch console port to the factory defaults, follow these steps:
Step 1 Enter R (the Reset main console RS232 interface to 9600,8,1,N option) from the Diagnostic Console - System Debug Interface Menu.
The following prompt is displayed:
Return system to factory defaults? [Y]es or [N]o:
Entering N redisplays the Diagnostic Console - System Debug Interface Menu.
Step 2 Enter Y.
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Wed Feb 24 14:17:18 PST 1999