cc/td/doc/product/lan/cat6000/sw_5_3
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

Configuring NetFlow Data Export

Configuring NetFlow Data Export

This chapter describes how to configure NetFlow Data Export (NDE) on the Catalyst 6000 family switches.


Note For more information on the syntax and usage for the commands used in this chapter, refer to the Catalyst 6000 Family Command Reference publication.

This chapter contains these sections:

Understanding How NDE Works

These sections describe how NDE works:

Overview of NDE and Integrated MLS Management

You can use NDE to monitor all IP Multilayer Switching (MLS) intersubnet traffic through the Multilayer Switch Feature Card (MSFC). NDE complements the embedded Remote Monitoring (RMON) capabilities on the switch that allow you to see all port traffic.


Note NDE is not supported for IP multicast MLS or Internetwork Packet Exchange (IPX) MLS.

Note For information on configuring IP MLS, see
"Configuring IP Multilayer Switching."

Integrated MLS management includes products, management utilities, and partner applications designed to gather flow statistics, export the statistics, collect and perform data reduction on the exported statistics, and forward them to applications for traffic monitoring, planning, and accounting. Flow collectors, such as the Cisco SwitchProbe and NetFlow FlowCollector, gather and classify flows. This flow information is then aggregated and fed to applications such as TrafficDirector, NetSys, or NetFlow Analyzer.

MLS Data Collection

An external data collector gathers flow entries from the MLS cache of one or more switches or Cisco routers. The switch or router transmits data to the flow collector by grouping flow entries for expired flows from its MLS cache into a User Datagram Protocol (UDP) datagram, which consists of a header and a series of flow entries. See Figure 6-1.


Figure 6-1: Integrated MLS Management


Using NDE Filters

By default, all expired flows are exported until you specify a filter. After specifying a filter, only expired and purged flows matching the specified filter criteria are exported. Filter values are stored in NVRAM and are not cleared when NDE is disabled.

If the flow mask is destination-ip mode and the NDE filter contains a filter on both source and destination, only the destination filter is effective. For example, in the filter specified in the following display if the flow mask is in destination-ip mode, all flows with destination address 9.1.2.15 are exported. The source filter for host 10.1.2.15 is not effective (it is ignored).

Console> (enable) set mls nde flow destination 9.1.2.15/32 source 10.1.2.15/32
Netflow data export: destination filter set to 9.1.2.15/32
Netflow data export: source filter set to 10.1.2.15/32
Console> (enable)

Default NetFlow Data Export Configuration

Table 6-1 shows the default NDE configuration.


Table 6-1: Default NetFlow Data Export Configuration
Feature Default Value

NDE

Disabled

NDE data collector address and UDP port

None specified

NDE filters

None configured

Configuring NetFlow Data Export

These sections describe how to configure NDE:

Specifying a NetFlow Data Export Address

The MSFC and the PFC use the NDE IP address when sending MLS statistics to a data collection application. You must configure the IP address on the MSFC so the data collection application can aggregate export data from both the MSFC and the PFC for the same flow.

If you do not specify an NDE IP address for the MSFC, the MSFC automatically selects the IP address of one of its interfaces and uses that IP address as its NDE IP address and its MLS IP address.

If you manually specify an NDE IP address for the MSFC, the MSFC uses this IP address as its MLS IP address (as shown in the output of the show mls command), replacing the one that was automatically selected.

After specifying the NDE IP address for the MSFC, enter the show mls command and note the "mls ip address." You must add this address to the included MLS router list on the switch.

Caution When you enable MLS on the router, the MSFC automatically selects one of its interfaces as the NDE IP address. If you later enable NDE and you specify a different NDE IP address from the automatically selected address, you must include the new MLS IP address in the list of routers participating in MLS on the switch.

To specify an NDE IP address for the MSFC, perform this task in global configuration mode:
Task Command

Specify the NDE IP address for the router.

Router(config)# mls nde-address [ip_addr]

This example shows how to specify an NDE IP address on the MSFC:

Router(config)# mls nde-address 170.170.2.1
Router(config)# 

Specifying a NetFlow Data Export Collector

Before enabling NDE for the first time, you must specify an NDE collector and UDP port to receive the exported statistics. The collector address and UDP port number are saved in NVRAM and are preserved if NDE is disabled and reenabled or if the switch is power cycled.


Note If you are using the NetFlow FlowCollector application for data collection, verify that the UDP port number you specify is the same port number shown in the FlowCollector's nfconfig.file. This file is located at /opt/csconfc/config/nfconfig.file in the FlowCollector application.

To specify a NetFlow data export collector, perform this task in privileged mode:
Task Command

Specify an NDE collector and UDP port.

set mls nde [collector_ip | collector_name] [udp_port_number]

This example shows how to specify a NetFlow data export collector:

Console> (enable) set mls nde Stargate 9996
Netflow data export not enabled.
Netflow data export to port 9996 on 172.20.15.1(Stargate)
Console> (enable)

Enabling NetFlow Data Export

To enable NDE, perform this task in privileged mode:
Task Command

Enable NDE on the switch.

set mls nde enable

This example shows how to enable NDE on the switch:

Console> (enable) set mls nde enable
Netflow data export enabled.
Netflow data export to port 9996 on 172.20.15.1 (Stargate)
Console> (enable)
 

If you attempt to enable NDE without first specifying a collector, you see this display:

Console> (enable) set mls nde enable
Please set host name and UDP port number with `set mls nde <collector_ip> <udp_port_number>'.
Console> (enable)

Specifying a Destination Host Filter

To specify a destination host filter, perform this task in privileged mode:
Task Command

Specify a destination host filter for an NDE flow.

set mls nde flow destination [ip_addr_spec]

This example shows how to set a destination host filter so that only expired flows to host 171.69.194.140 are exported:

Console> (enable) set mls nde flow destination 171.69.194.140
Netflow Data Export successfully set
Destination filter is 171.69.194.140/255.255.255.255
Filter type: include
Console> (enable)

Specifying a Destination and Source Subnet Filter

To specify a destination and source subnet filter, perform this task in privileged mode:
Task Command

Specify a destination and source subnet filter for an NDE flow.

set mls nde flow destination [ip_addr_spec] source [ip_addr_spec]

This example shows how to specify a destination and source subnet filter so that only expired flows to subnet 171.69.194.0 from subnet 171.69.173.0 are exported (assuming the flow mask is set to source-destination-ip):

Console> (enable) set mls nde flow destination 171.69.194.140/24 source 171.69.173.5/24
Netflow Data Export successfully set
Source filter is 171.69.173.0/24
Destination filter is 171.69.194.0/24
Filter type: include
Console> (enable)

Specifying a Destination TCP/UDP Port Filter

To specify a destination TCP/UDP port filter, perform this task in privileged mode:
Task Command

Specify a destination TCP/UDP port filter for an NDE flow.

set mls nde flow dst_prt [port_number]

This example shows how to specify a destination TCP/UDP port filter so that only expired flows to destination port 23 are exported (assuming the flow mask is set to ip-flow):

Console> (enable) set mls nde flow dst_port 23
Netflow Data Export successfully set
Destination port filter is 23
Filter type: include
Console> (enable)

Specifying a Source Host and Destination TCP/UDP Port Filter

To specify a source host and destination TCP/UDP port filter, perform this task in privileged mode:
Task Command

Specify a source host and destination TCP/UDP port filter for an NDE flow.

set mls nde flow source [ip_addr_spec] dst_prt [port_number]

This example shows how to specify a source host and destination TCP/UDP port filter so that only expired flows from host 171.69.194.140 to destination port 23 are exported (assuming the flow mask is set to ip-flow):

Console> (enable) set mls nde flow source 171.69.194.140 dst_port 23
Netflow Data Export successfully set
Source filter is 171.69.194.140/255.255.255.255
Destination port filter is 23
Filter type: include
Console> (enable)

Specifying a Protocol Filter

To specify a protocol filter, perform this task in privileged mode:
Task Command

Specify a protocol filter for an NDE flow.

set mls nde flow protocol protocol

This example shows how to specify a protocol filter so that only expired flows from protocol 17 are exported:

Console> (enable) set mls nde flow protocol 17
Netflow Data Export filter successfully set.
Protocol filter is 17
Filter type: include
Console> (enable)

Specifying Protocols for Statistics Collection

You can use the set mls statistics protocol protocol command to specify up to 64 different protocols for which to collect statistics to be exported using NDE. The protocol argument can be tcp, udp, icmp, or a decimal number for other protocol families.

To specify protocols for statistics collection, perform this task in privileged mode:
Task Command

Specify protocols for statistics collection.

set mls statistics protocol protocol

This example shows how to specify a protocol for statistics collection:

Console> (enable) set mls statistics protocol 17 
Protocol 17 is added to protocol statistics list.
Console> (enable)

Removing Protocols for Statistics Collection

You can use the clear mls statistics protocol {protocol port | all} command to specify up to 64 different protocols for which to collect statistics to be exported using NDE. The protocol argument can be tcp, udp, icmp, or a decimal number for other protocol families. The port argument specifies the protocol port. Use the all keyword to remove all protocols for statistics collection.

To remove protocols for statistics collection, perform this task in privileged mode:
Task Command

Remove protocols for statistics collection.

clear mls statistics protocol {protocol port | all}

This example shows how to remove a protocol for statistics collection:

Console> (enable) clear mls statistics protocol 17 1934
Protocol 17 port 1934 cleared from protocol statistics list.
Console> (enable)

Clearing an NDE Flow Filter

To clear the NDE flow filter and reset the filter to the default (all flows exported), perform this task in privileged mode:
Task Command

Clear the NDE flow filter.

clear mls nde flow

This example shows how to clear the NDE flow filter so that all flows are exported:

Console> (enable) clear mls nde flow 
Netflow data export filter cleared.
Console> (enable)

Disabling NetFlow Data Export


Note If NDE is enabled and you disable MLS, you lose the statistics for existing cache entries--- they are not exported.

To disable NDE, perform this task in privileged mode:
Task Command

Disable NDE on the switch.

set mls nde disable

This example shows how to disable NDE on the switch:

Console> (enable) set mls nde disable
Netflow data export disabled.
Console> (enable)

Removing the NetFlow Data Export Address

To remove the NDE IP address from the MSFC, perform this task in global configuration mode:
Task Command

Remove the NDE IP address for the router.

Router(config)# no mls nde-address [ip_addr]

This example shows how to remove the NDE IP addresses on the MSFC:

Router(config)# no mls nde-address 170.170.2.1
Router(config)# 

Displaying the NDE Configuration

To display the NDE configuration, perform this task in privileged mode:
Task Command

Show the NDE configuration on the switch.

show mls nde

This example shows how to display the NDE configuration on the switch:

Console> (enable) show mls nde
Netflow Data Export enabled
Netflow Data Export configured for port 1098 on host 172.20.15.1 
Source filter is 171.69.194.140/255.255.255.0
Destination port filter is 23
Total packets exported = 26784
Console> (enable)
 


hometocprevnextglossaryfeedbacksearchhelp