This chapter provides basic configuration and management information for the ATM modules and describes the command-line interface (CLI) used to configure the ATM modules for the Catalyst 5000 and 6000 families of switches.
![]() |
Note For descriptions of all ATM commands, refer to "Command Reference." |
This chapter consists of these sections:
The ATM modules use a subset of the Cisco IOS software. The Cisco IOS user interface provides access to several different command modes. Each command mode provides a group of related commands.
Cisco IOS software provides two command access modes: user EXEC and privileged EXEC. The user EXEC mode does not require a password and allows you direct access only to the ATM module with which you have established a session. The user EXEC mode commands are a subset of the privileged EXEC mode commands.
The privileged EXEC mode requires a password (the default password is atm). From the privileged level, you can access the six configuration modes:
Enter a question mark (?) at the system prompt to display the available commands for the current command mode.
Almost every configuration command has a no form. The no form disables a feature or function. Enter the command without the keyword no to reenable a disabled feature or to enable a feature that is disabled by default. Refer to "Command Reference" for more information about the ATM module commands.
The user interface also provides context-sensitive help on command syntax. For information on how to use the help system, refer to the "Getting Context-Sensitive Help" section. The user interface also describes the command editing and command history features that allow you to recall previous command entries and easily edit command entries.
This example shows how to open a session on an ATM module installed in slot 4:
Console>session 4 Enter Password:ATM>
This section describes the command modes and functions that allow you to access and operate the ATM module CLI. Table 2-1 lists the command modes, how to access each mode, the prompt you see while you are in that mode, the main uses for each configuration mode, and the method to exit that mode. The prompts listed assume the default name ATM.
| Command Mode | Access Method | Prompt | Exit Method |
|---|---|---|---|
User EXEC | Use the session command in the switch CLI. | ATM> | Enter the logout command. |
Privileged EXEC | From user EXEC mode, enter the enable EXEC command. Enter the enable password at the prompt (default is atm). | ATM# | Enter the disable command. |
Global configuration | From privileged EXEC mode, enter the configure privileged EXEC command. | ATM(config)# | Enter the exit or end command, or press Control-Z. |
Interface configuration | From global configuration mode, enter the interface interface_num command. | ATM (config-if)# | To exit to global configuration mode, enter the end command. To exit to privileged EXEC mode, enter the exit command, or press Control-Z. |
Subinterface configuration | From interface configuration mode, enter the interface sub_interface_num command. | ATM (config-subif)# | To exit to global configuration mode, enter the end command. To exit to privileged EXEC mode, enter the exit command, or press Control-Z. |
Line configuration | From global configuration mode, enter the line line_number command. | ATM (config-line)# | To exit to global configuration mode, enter the exit command. To exit to privileged EXEC mode, enter the end command, or press Control-Z. |
LANE database configuration | From global configuration mode, enter the lane database command. | ATM (config-if)# | To exit to global configuration mode, enter the exit command. To exit to privileged EXEC mode, enter the end command, or press Control-Z. |
After you log in to the ATM module, you are automatically in user EXEC command mode. The user EXEC commands are a subset of the privileged EXEC commands. The user EXEC commands allow you to change terminal settings on a temporary basis, perform basic tests, and list system information.
To list the commands available in user EXEC mode, enter a question mark (?) at the ATM> prompt.
Because many privileged commands set operating parameters, use password protection to restrict access to privileged EXEC mode. The privileged EXEC command set includes those commands in user EXEC mode, as well as the configure command through which you can access the remaining command modes. Privileged EXEC mode also includes high-level testing commands, such as debug.
To access and list the privileged EXEC commands, perform this task:
| Task | Command |
|---|---|
1. Enter privileged EXEC mode. | enable password |
2. List privileged EXEC commands. | ? |
If the system administrator has set a password, you are prompted to enter it before you are allowed access to privileged EXEC mode. The password is not displayed on the screen and is case sensitive. If an enable password has not been set, you can only access privileged EXEC mode from the console. The default password for the ATM module is atm.
This example shows how to access privileged EXEC mode:
ATM> enable Password: ATM#
From privileged EXEC mode, you can access global configuration mode. For instructions, see the "Accessing Global Configuration Mode" section.
To return from privileged EXEC mode to user EXEC mode, perform this task:
| Task | Command |
|---|---|
Exit privileged EXEC mode and return to user EXEC mode. | disable |
Global configuration commands apply to features that affect the ATM module as a whole. To enter global configuration mode, enter the configure privileged EXEC command. When you enter this command, the privileged EXEC mode prompts you for the source of the configuration commands, as follows:
Configuring from terminal, memory, or network [terminal]?
![]() |
Note Only the write memory and write terminal commands are supported. The write network command is not supported. |
You can specify either the terminal or NVRAM as the source of configuration commands (refer to the Cisco IOS configuration guide and command reference publications for complete information on Cisco IOS commands). The default is to enter commands from the console terminal. Press Return to enter terminal configuration mode.
To access and list the global configuration commands, perform this task:
| Task | Command | |
|---|---|---|
Step 1 | At the console terminal, from privileged EXEC mode, enter global configuration mode. | configure |
Step 2 | List the global configuration commands. | ? |
This example shows how to access global configuration mode:
ATM#configure terminal Enter configuration commands, one per line. End with CNTL/Z. ATM(config)#
To exit global configuration command mode and return to privileged EXEC mode, perform this task using one of these commands:
| Task | Command |
|---|---|
Exit global configuration mode. | exit |
Interface configuration commands modify the operation of the ATM interface. Interface configuration commands always follow an interface global configuration command, which defines the interface type.
To access and list the interface configuration commands, perform this task:
| Task | Command | |
|---|---|---|
Step 1 | interface configuration mode. | interface atm01 |
Step 2 | List the interface configuration commands. | ? |
Step 3 | From interface configuration mode, enter subinterface configuration mode. | interface atm0.sub_interface_num |
Step 4 | List the subinterface configuration commands. | ? |
| 1Always specify ATM interface 0 for the ATM module. |
This example shows how to access interface configuration mode:
ATM(config)#interface atm0 ATM(config-if)#
This example shows how to access subinterface configuration mode:
ATM(config-if)#interface atm0.1 ATM(config-subif)#
To exit interface configuration mode and return to global configuration mode, perform this task:
| Task | Command |
|---|---|
Exit interface configuration mode. | exit |
To exit global configuration mode and return to privileged EXEC mode, perform this task using one of these commands:
| Task | Command |
|---|---|
Exit global configuration mode. | end |
Line configuration commands modify the operation of a terminal line. Line configuration commands always follow a line command, which defines a line number. These commands change terminal parameter settings either on a line-by-line basis or for a range of lines.
To access and list the virtual terminal line configuration commands, perform this task:
| Task | Command | |
|---|---|---|
Step 1 | From global configuration mode, configure a virtual terminal line. | line [vty] line-number [ending-line-number]1 |
Step 2 | List the line configuration commands. | ? |
| 1This command is documented in the "Terminal Lines and Modem Support Commands" chapter in the Router Products Command Reference publication. |
This example shows how to enter line configuration mode for virtual terminal line 4:
ATM(config)#line 0 4 ATM(config-line)#
To exit line configuration mode and return to global configuration mode, perform this task:
| Task | Command |
|---|---|
Exit line configuration mode. | exit |
To exit global configuration mode and return to privileged EXEC mode, perform this task using one of these commands:
| Task | Command |
|---|---|
Exit global configuration mode. | end |
This section contains the following subsections:
You can download system software images to the ATM modules using the Trivial File Transfer Protocol (TFTP) or Remote Copy Protocol (rcp). Both methods allow you to download image files over the network from a server.
When you download a software image file to an ATM module, the switch checks the header of the image file to determine the type of software image.
When you download ATM module software images, you can either specify the module to which the image file should be downloaded or not specify the module, in which case the software image is downloaded to all ATM modules installed in the switch. The file is relayed packet by packet to the appropriate modules using the Inter-Process Communications protocol internal to the system, with communication taking place across the switching bus. Downloading a software image to multiple modules significantly speeds up the process of updating the software on multiple modules of the same type.
Before you begin downloading a software image, make sure of the following:
Step 2 Log into the switch through the console port or a Telnet session. If you log in using Telnet, your Telnet session might disconnect when you reset modules to run the new software.
Step 3 Use the command appropriate for your switch and supervisor engine to download the software image from the TFTP server:
![]() |
Note If you do not specify a module number, the switch examines the header of the image file to determine to which modules the software is downloaded. The image is then downloaded to all the modules of that type. |
The switch downloads the image file, erases the Flash memory on the appropriate modules, and reprograms the Flash memory with the downloaded Flash code.
![]() |
Note All modules in the switch remain operational while the image downloads. |
Step 4 Reset the appropriate modules using the reset mod_num command. If you are connected through Telnet, your Telnet session disconnects if you reset the module through which your connection was made.
Step 5 When the upgraded modules come online, enter the show version [mod_num] command to check the version of the code on the switch.
![]() |
Note For examples that show complete procedures for downloads to intelligent modules, see the "Example Single Intelligent Module Image Download (Catalyst 5000 Family Supervisor II, II G, or III G)" section, the "Example Multiple Module Image Download (Supervisor II, II G, or III G)" section, the "Example Single Module Image Download (Supervisor III or III F)" section and the "Example Multiple Module Image Download (Supervisor III or III F)" section. |
These sections show example download procedures:
![]() |
Note For a step-by-step procedure for downloading software images to ATM modules on a Catalyst 5000 family switch with a Supervisor Engine III or III F, refer to the "Downloading ATM Module Images" section. |
This example shows a complete TFTP download procedure of an ATM software image to a single ATM module in a Catalyst 5000 family switch with a Supervisor Engine III or III F module:
Console> (enable) show version 4
Mod Port Model Serial # Versions
--- ---- ---------- --------- ----------------------------------------
4 1 WS-X5155 003414855 Hw : 1.2
Fw : 1.3
Fw1: 1.3
Sw : 3.2(6)
Console> (enable) copy tftp 4/flash
IP address or name of remote host []? 172.20.52.3
Name of file to copy from []? cat5000-atm.3-2-7.bin
Download image tftp:cat5000-atm.3-2-7.bin to Module 4 FLASH (y/n) [n]? y
This command will reset Download Module(s) you selected.
Do you wish to continue download flash (y/n) [n]? y
-
Download done for module 4, please wait for it to come online
File has been copied successfully.
Console> (enable) 07/21/1998,13:13:54:SYS-5:Module 4 is online
Console> (enable) show version 4
Mod Port Model Serial # Versions
--- ---- ---------- --------- ----------------------------------------
4 1 WS-X5155 003414855 Hw : 1.2
Fw : 1.3
Fw1: 1.3
Sw : 3.2(7)
Console> (enable)
![]() |
Note For a step-by-step procedure for downloading software images to intelligent modules on a Catalyst 5000 family switch with a Supervisor Engine II, II G, or III G, refer to the "Downloading ATM Module Images" section. |
This example shows a complete TFTP download procedure of an FDDI software image to a single ATM module in a Catalyst 5000 family switch with a Supervisor Engine II, II G, or III G module:
Console> (enable) show version 3
Mod Port Model Serial # Versions
--- ---- ---------- --------- ----------------------------------------
3 2 WS-X5155 003414855 Hw : 1.2
Fw : 1.3
Fw1: 1.3
Sw : 3.2(6)
Console> (enable) download 172.20.52.3 cat5000-fddi.3-1-1.bin 3
This command will reset module 3.
Download image cat5000-fddi.3-1-1.bin from 172.20.52.3 to Module 3 FLASH (y/n) [
n]? y
|
Finished network single module download. (1060456 bytes)
...............................................................................
...............................................................................
...............................................................................
...............................................................................
...............................................................................
..................................
SCP download checksum ok
SCP download done.
Please wait until module 3 comes online before resetting.
(Approximately 5 minutes)
Console> (enable) Console> (enable) 07/21/1998,11:23:36:SYS-5:Module 3 FLASH pro
gramming complete
07/21/1998,11:24:59:SYS-5:Module 3 is online
07/21/1998,11:25:00:DTP-5:Port 3/1-2 has become dot10 trunk
Console> (enable) show version 3
Mod Port Model Serial # Versions
--- ---- ---------- --------- ----------------------------------------
3 2 WS-X5155 003414855 Hw : 1.2
Fw : 1.3
Fw1: 1.3
Sw : 3.2(7)
Console> (enable)
![]() |
Note For a step-by-step procedure for downloading software images to intelligent modules on a Catalyst 5000 family switch with a Supervisor Engine III or III F, refer to the "Downloading ATM Module Images" section. |
This example shows a complete TFTP download procedure of an ATM software image to multiple ATM modules in a Catalyst 5000 family switch with a Supervisor Engine III or III F module:
Console> (enable) show version 4
Mod Port Model Serial # Versions
--- ---- ---------- --------- ----------------------------------------
4 1 WS-X5155 003414855 Hw : 1.2
Fw : 1.3
Fw1: 1.3
Sw : 3.2(6)
Console> (enable) show version 5
Mod Port Model Serial # Versions
--- ---- ---------- --------- ----------------------------------------
5 1 WS-X5155 003414463 Hw : 1.2
Fw : 1.3
Fw1: 1.3
Sw : 3.2(6)
Console> (enable) copy tftp flash
IP address or name of remote host []? 172.20.52.3
Name of file to copy from []? cat5000-atm.3-2-7.bin
Download image tftp:cat5000-atm.3-2-7.bin to Module 4 FLASH (y/n) [n]? y
Download image tftp:cat5000-atm.3-2-7.bin to Module 5 FLASH (y/n) [n]? y
This command will reset Download Module(s) you selected.
Do you wish to continue download flash (y/n) [n]? y
-
Download done for module 4, please wait for it to come online
Download done for module 5, please wait for it to come online
File has been copied successfully.
Console> (enable) 07/21/1998,12:25:10:SYS-5:Module 4 is online
07/21/1998,12:25:10:SYS-5:Module 5 is online
Console> (enable) show version 4
Mod Port Model Serial # Versions
--- ---- ---------- --------- ----------------------------------------
4 1 WS-X5155 003414855 Hw : 1.2
Fw : 1.3
Fw1: 1.3
Sw : 3.2(7)
Console> (enable) show version 5
Mod Port Model Serial # Versions
--- ---- ---------- --------- ----------------------------------------
5 1 WS-X5155 003414463 Hw : 1.2
Fw : 1.3
Fw1: 1.3
Sw : 3.2(7)
Console> (enable)
![]() |
Note For a step-by-step procedure for downloading software images to intelligent modules on a Catalyst 5000 family switch with a Supervisor Engine II, II G, or III G, refer to the "Downloading ATM Module Images" section. |
This example shows a complete TFTP download procedure of an ATM software image to multiple ATM modules in a Catalyst 5000 family switch with a Supervisor Engine II, II G, or III G module:
Console> (enable) show version 8
Mod Port Model Serial # Versions
--- ---- ---------- --------- ----------------------------------------
8 1 WS-X5155 003414855 Hw : 1.2
Fw : 1.3
Fw1: 1.3
Sw : 3.2(4)
Console> (enable) show version 9
Mod Port Model Serial # Versions
--- ---- ---------- --------- ----------------------------------------
9 1 WS-X5155 003414463 Hw : 1.2
Fw : 1.3
Fw1: 1.3
Sw : 3.2(6)
Console> (enable) download 172.20.52.3 cat5000-atm.3-2-7.bin
Download image cat5000-atm.3-2-7.bin from 172.20.52.3 to Module 8 FLASH (y/n) [n
]? y
Download image cat5000-atm.3-2-7.bin from 172.20.52.3 to Module 9 FLASH (y/n) [n
]? y
This command will reset download module(s) you selected.
Do you wish to continue download to flash (y/n) [n]? y
-
Download done for module 8, please wait for it to come online
Download done for module 9, please wait for it to come online
Finished network multiple modules download. (2378316 bytes)
Please wait until module(s) come online before resetting.
Console> (enable) 07/21/1998,13:19:54:SYS-5:Module 8 is online
07/21/1998,13:19:54:SYS-5:Module 9 is online
Console> (enable) show version 8
Mod Port Model Serial # Versions
--- ---- ---------- --------- ----------------------------------------
8 1 WS-X5155 003414855 Hw : 1.2
Fw : 1.3
Fw1: 1.3
Sw : 3.2(7)
Console> (enable) show version 9
Mod Port Model Serial # Versions
--- ---- ---------- --------- ----------------------------------------
9 1 WS-X5155 003414463 Hw : 1.2
Fw : 1.3
Fw1: 1.3
Sw : 3.2(7)
Console> (enable)
This section describes how to perform the following functions:
You can get a list of the associated keywords and arguments for any command by using the context-sensitive help feature.
To get help specific to a command mode, a command, a keyword, or arguments, perform one of
these tasks:
| Task | Command |
|---|---|
| help |
| full-help |
| terminal full-help1 |
| abbreviated-command-entry? |
| abbreviated-command-entry<Tab> |
| ? |
| command ? |
| command keyword ? |
| 1This command is documented in the Cisco Access Connection Guide. |
When using context-sensitive help, the space (or lack of a space) before the question mark (?) is significant.
To obtain a list of commands that begin with a particular character sequence, enter the characters immediately followed by the question mark (?). Do not include a space. This form of help completes the word for you.
To list keywords or arguments, enter command syntax help by entering a question mark (?) in place of a keyword or argument. Include a space before the ?. This form of help reminds you which keywords or arguments are applicable based on the command, keywords, and arguments you have already entered.
You can abbreviate commands and keywords by using a number of characters that allow a unique abbreviation. For example, you can abbreviate the show command to sh.
Enter the help command (which is available in any command mode) for a brief description of the help system:
ATM#helpHelp may be requested at any point in a command by enteringa question mark '?'. If nothing matches, the help list willbe empty and you must back up until entering a '?' shows theavailable options.Two styles of help are provided:1. Full help is available when you are ready to enter acommand argument (e.g. 'show ?') and describes each possibleargument.2. Partial help is provided when an abbreviated argument is enteredand you want to know what arguments match the input(e.g. 'show pr?'.)
You can enter a partial command name and a question mark (?) to obtain a list of commands beginning with a particular character set. See the "Completing a Partial Command Name" section for more details.
This example shows how context-sensitive help enables you to create an access list from configuration mode. Enter co at the system prompt followed by a question mark (?). Do not leave a space between the last letter and the question mark (?). The system provides the commands that begin with co.
ATM#co? configure connect copy
Enter the configure command followed by a space and a question mark (?) to list the command's keywords and a brief explanation:
ATM#configure ? memory Configure from NV memory network Configure from a TFTP network host terminal Configure from the terminal <cr>
An error indicator (^) symbol appears at the point in the command string where you have entered an incorrect command, keyword, or argument. The error location indicator and interactive help system allow you to easily find and correct syntax errors.
This example shows how to use context-sensitive help to determine how to clear an ATM interface.
First, check the syntax for the command:
ATM#clear ? counters Clear counters on one or all interfaces interface Clear the hardware logic on an interface lane lane line Reset a terminal line logging Clear logging buffer tcp Clear a TCP connection or statistics ATM#clear
The help output shows that clear interface is the syntax for clearing an interface. Next, check the syntax for specifying the type of interface:
ATM#clear interface ? ATM ATM interface Ethernet IEEE 802.3 Null Null interface ATM#clear interface
The help output shows that clear interface atm is the syntax for clearing an ATM interface. Next, check the syntax for specifying the specific ATM interface:
ATM#clear interface atm ? <0-0> ATM interface number ATM#clear interface atm
The help output shows you must specify the ATM interface number. When you specify the interface correctly, the ATM interface is cleared:
ATM#clear interface atm 0 ATM#
The command history feature keeps a record of commands you have entered and allows you to recall these commands. The functions of the command history feature are as follows:
By default, the system records ten command lines in its history buffer. To set the number of command lines the system records during the current terminal session, perform this task in user EXEC mode
:
| Task | Command |
|---|---|
Enable the command history feature for the current terminal session. | terminal history [size number-of-lines]1 |
| 1This command is documented in the Cisco Access Connection Guide. |
The terminal no history size command resets the number of lines saved by history to the default of ten lines.
To configure the number of command lines the system records, perform this task in line configuration mode:
| Task | Command |
|---|---|
Enable the command history feature. | history [size number-of-lines]1 |
| 1The no history command turns off command history for the line. |
To recall commands from the history buffer, perform one of these tasks:
| Task | Key Sequence/Command |
|---|---|
| Press Control-P or the up arrow key1. |
| Press Control-N or the down arrow key1. |
| show history |
| 1The arrow keys function only on ANSI-compatible terminals such as VT100s. |
The command history feature is enabled automatically. To disable it during the current terminal session, perform this task in user EXEC mode:
| Task | Command |
|---|---|
Disable the command history feature for the current session. | terminal no history1 |
| 1This command is documented in the Cisco Access Connection Guide. |
To configure a specific line so that the command history feature is disabled, perform this task in line configuration mode:
| Task | Command |
|---|---|
Configure the line so that the command history feature is disabled. | no history |
Catalyst 5000 family ATM software release 2.3 and above includes an enhanced editing mode that provides a set of editing key functions similar to those of the Emacs editor. You can enter commands in uppercase, lowercase, or a mix of both. Only passwords are case sensitive. You can abbreviate commands and keywords to the number of characters that allow a unique abbreviation.
For example, you can abbreviate the show command to sh. After entering the command at the system prompt, press Return to execute the command.
Although enhanced editing mode is enabled automatically, you can disable it and revert to the editing mode of previous software releases. For more information, see the "Ending a Session" section.
To reenable the enhanced editing mode for the current terminal session, perform this task in user EXEC mode:
| Task | Command |
|---|---|
Enable the enhanced editing features for the current terminal session. | terminal editing1 |
| 1This command is documented in the Cisco Access Connection Guide. |
To reconfigure a specific line in enhanced editing mode, perform this task in line configuration mode:
| Task | Command |
|---|---|
Enable the enhanced editing features. | editing |
Perform one of these tasks to move the cursor around on the command line for corrections or changes:
| Task | Keystrokes |
| Press Control-B or |
| Press Control-F or |
| Press Control-A. |
| Press Control-E. |
| Press Esc B. |
| Press Esc F. |
| 1The arrow keys function only on ANSI-compatible terminals such as VT100s. |
If you cannot remember a complete command name, press the Tab key to allow the system to complete a partial entry. To do so, perform this task:
| Task | Keystrokes |
|---|---|
Complete a command name. | Enter the first few letters, and press the Tab key. |
If your keyboard does not have a Tab key, press Control-I instead.
In the following example, when you enter the letters conf and press the Tab key, the system provides the complete command:
ATM#conf<Tab> ATM#configure
If you enter a set of characters that could indicate more than one command, the system beeps to indicate an error. Enter a question mark (?) to obtain a list of commands that begin with that set of characters. Do not leave a space between the last letter and the question mark (?). For example, three commands in privileged mode start with co. To see what they are, enter co? at the privileged EXEC prompt. The system displays all commands that begin with co, as follows:
ATM#co? configure connect copy
The system provides a buffer that contains the last ten items you deleted. You can recall these items and paste them in the command line by performing this task:
| Task | Command | |
|---|---|---|
Step 1 | Recall the most recent entry in the buffer. | Press Control-Y. |
Step 2 | Recall the next buffer entry. | Press Esc Y. |
The buffer contains only the last ten items you have deleted or cut. If you press Esc Y more than ten times, you cycle back to the first buffer entry.
The editing command set provides a wraparound feature for commands that extend beyond a single line on the screen. When the cursor reaches the right margin, the command line shifts ten spaces to the left. You cannot see the first ten characters of the line, but you can scroll back and check the syntax at the beginning of the command. To scroll back, perform this task:
| Task | Keystrokes |
|---|---|
Return to the beginning of a command line to verify that you have entered a lengthy command correctly. | Press Control-B or the left arrow key repeatedly until you scroll back to the beginning of the command entry, or press Control-A to return directly to the beginning of the line1. |
| 1The arrow keys function only on ANSI-compatible terminals such as VT100s. |
In this example, the lane config-atm-address command entry extends beyond one line. When the cursor reaches the end of the line, the line shifts ten spaces to the left and is redisplayed. The dollar sign ($) indicates that the line scrolled to the left. Each time the cursor reaches the end of the line, the line shifts ten spaces to the left.
ATM(config-subif)#lane config-atm-address 39.000000000000014155551211.080020 ATM(config-subif)#$ -atm-address 39.000000000000014155551211.0800200c1001.00
When you complete the entry, press Control-A to check the complete syntax, and then press Return to execute the command. The dollar sign ($) appears at the end of the line to indicate that the line scrolled to the right:
ATM(config-subif)#lane config-atm-address 39.000000000000014155551211.080020 $
The system assumes your terminal screen is 80 columns wide. If your screen has a different width, enter the terminal width command to tell the router the correct width of your screen.
Use line wrapping with the command history feature to recall and modify previous complex command entries. See the "Recalling Commands" section for information about recalling previous command entries.
Perform one of these tasks to delete command entries if you make a mistake or change your mind:
| Task | Keystrokes |
|---|---|
| Press the Delete or Backspace key. |
| Press Control-D. |
| Press Control-K. |
| Press Control-U or Control-X. |
| Press Control-W. |
| Press Esc D. |
When you use the help facility to list the commands in a particular mode, the list is often longer than the terminal screen can display. In such cases, a ---More--- prompt is displayed at the bottom of the screen. To view the next line or screen, perform these tasks:
| Task | Keystrokes |
|---|---|
| Press the Return key. |
| Press the Spacebar. |
![]() |
Note The ---More--- prompt is used for any output that has more lines than can be displayed on the terminal screen, including show command output. |
If you enter a command and the system suddenly sends a message to your screen, you can recall your current command line entry. To do so, perform this task:
| Task | Keystrokes |
|---|---|
Redisplay the current command line. | Press Control-L or Control-R. |
If you mistype a command entry, you can transpose the mistyped characters by performing this task:
| Task | Keystrokes |
|---|---|
Transpose the character to the left of the cursor with the character located at the cursor. | Press Control-T. |
You can change words to uppercase or lowercase, or capitalize a set of letters, by performing these tasks:
| Task | Keystrokes |
|---|---|
| Press Esc C. |
| Press Esc L. |
| Press Esc U. |
To use a particular keystroke as an executable command, perform this task:
| Task | Keystrokes |
|---|---|
Insert a code to indicate to the system that the keystroke immediately following should be treated as a command entry, not an editing key. | Press Control-V or Esc Q. |
After entering the setup command or other configuration commands, exit the ATM module and quit the session.
To end a session, perform this task:
| Task | Command |
|---|---|
Enter the quit EXEC command. | quit |
The Catalyst 5000 and 6000 families' dual physical-sublayer (dual PHY) ATM modules provide one active connection and one standby connection to the ATM network. You can connect both PHYs to a single ATM switch, or you can connect one PHY to one ATM switch and one PHY to a second ATM switch.
Only one PHY is active at a time. If the active PHY loses its connection, the ATM module switches automatically to the standby PHY. PHY A is the preferred PHY by default. You can change the preferred PHY using the atm preferred phy interface configuration command.
Software release version 12.0(4a)W5(10) and later supports the Fast PHY switchover feature on the ATM modules. Fast switchover reduces the time to restore traffic flow when traffic switches from the active PHY to the redundant PHY.
To change the preferred PHY on the dual PHY ATM modules, perform this task in interface configuration mode
:
| Task | Command |
|---|---|
Change the preferred PHY to the one not currently in use. | atm preferred phy {A | B} |
This example shows how to change the preferred PHY to PHY B:
ATM#configure terminal Enter configuration commands, one per line. End with CNTL/Z. ATM(config)#interface atm0 ATM(config-if)#atm preferred phy B ATM(config-if)#^Z ATM#
The show interface command displays the preferred and active PHY:
ATM#show interface atm0
ATM0 is up, line protocol is up
Hardware is Catalyst 5000 ATM
MTU 1500 bytes, sub MTU 0, BW 156250 Kbit, DLY 80 usec, rely 255/255, load 125
Encapsulation ATM, loopback not set, keepalive not supported
Encapsulation(s): AAL5, PVC mode
4096 maximum active VCs, 1024 VCs per VP, 3 current VCCs
VC idle disconnect time: 300 seconds
Signalling vc = 1, vpi = 0, vci = 5
UNI Version = 3.0, Link Side = user
Preferred Phy : PHY B
Currently Active Phy : PHY B
Link Status : UP
Standby Phy Status : UP
Last input 00:00:00, output never, output hang never
Last clearing of "show interface" counters 1d23h
Queueing strategy: fifo
Output queue 0/40, 0 drops; input queue 0/75, 0 drops
5 minute input rate 1000 bits/sec, 1 packets/sec
5 minute output rate 132043000 bits/sec, 1 packets/sec
1720746 packets input, 101473920 bytes, 0 no buffer
Received 0 broadcasts, 0 runts, 0 giants, 0 throttles
0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored, 0 abort
1720745 packets output, 3872214384 bytes, 0 underruns
0 output errors, 0 collisions, 0 interface resets
0 output buffer failures, 0 output buffers swapped out
ATM#
These sections describe how to configure basic parameters on the ATM modules:
To enable VTP on the ATM module, perform this task:
| Task | Command | |
|---|---|---|
Step 1 | Enter configuration mode. | configure terminal |
Step 2 | Enable VTP on the ATM module. | vtp enable |
Step 3 | Exit configuration mode. | Ctrl-Z |
This example shows how to enable VTP on the ATM module:
ATM#configure terminal Enter configuration commands, one per line. End with CNTL/Z. ATM(config)#vtp enable ATM(config)#^Z ATM#
To disable VTP on the ATM module, perform this task:
| Task | Command | |
|---|---|---|
Step 1 | Enter configuration mode. | configure terminal |
Step 2 | Disable VTP on the ATM module. | no vtp enable |
Step 3 | Exit configuration mode. | Ctrl-Z |
This example shows how to disable VTP on the ATM module:
ATM#configure terminal Enter configuration commands, one per line. End with CNTL/Z. ATM(config)#no vtp enable ATM(config)#^Z ATM#
You can configured the ATM modules on the Catalyst 5000 family and 2926G series switches to generate the transmit clock from its internal source or to set the clock-generation mode to receive timing from an external source. By default, the ATM module generates the transmit clock signal from its internal source. The default is loop-timed clock mode for the ATM dual PHY OC-3 modules (WS-X5167 and WS-X5168).
![]() |
Note The atm clock internal and the no atm clock internal commands are not supported by the ATM dual PHY OC-12 modules. |
To change the clock source, perform the following task in interface configuration mode:
| Task | Command | |
|---|---|---|
Step 1 | Enter configuration mode. | configure terminal |
Step 2 | Select the ATM interface. | interface atm0 |
Step 3 | Set the clock source | [no] atm clock internal |
Step 4 | Exit configuration mode. | Ctrl-Z |
This example shows how to set the ATM module to generate the transmit clock from its internal source:
ATM(config-if)#atm clock internal ATM(config-if)#
This example shows how to set the ATM module to generate the transmit clock from an external source:
ATM(config-if)#no atm clock internal ATM(config-if)#
You can configure the mode of operation and control type for cell-rate decoupling on the SONET PLIM using the atm sonet command. The default mode is STS-3c operation for the ATM dual PHY OC-3 modules and STS-12c operation for the ATM dual PHY OC-12 modules.
To configure the mode of operation, perform the following task in interface configuration mode:
| Task | Command | |
|---|---|---|
Step 1 | Enter configuration mode. | configure terminal |
Step 2 | Select the ATM interface. | interface atm0 |
Step 3 | Set the mode of operation | atm sonet {stm-1 | sts-3c} {stm-4 | sts-12c} |
Step 4 | Exit configuration mode. | Ctrl-Z |
This example shows how to set the mode for cell-rate decoupling on the SONET PLIM to stm-1:
ATM (config-if)#atm sonet stm-1 ATM (config-if)#
You can configure output throttling on the ATM modules to control the transmission rate on the ATM interface. Output throttling applies to both LANE and PVCs. Per-VC pacing is not supported on the modules.
To throttle the output of the entire interface, perform this task:
| Task | Command | |
|---|---|---|
Step 1 | Enter configuration mode. | configure terminal |
Step 2 | Select the ATM interface. | interface atm0 |
Step 3 | Apply output throttling to the interface. | atm traffic-shape rate peak_rate |
Step 4 | Exit configuration mode. | Ctrl-Z |
This example shows how to throttle the output of the ATM module interface to 100 Mbps:
ATM#configure terminal Enter configuration commands, one per line. End with CNTL/Z. ATM(config)#interface atm0 ATM(config-if)#atm traffic-shape rate 100 ATM(config-if)#^Z ATM#
To return the output rate to the default value for the interface, perform this task:
| Task | Command | |
|---|---|---|
Step 1 | Enter configuration mode. | configure terminal |
Step 2 | Select the ATM interface. | interface atm0 |
Step 3 | Apply output throttling to the interface. | no atm traffic-shape rate peak_rate |
Step 4 | Exit configuration mode. | Ctrl-Z |
This example shows how to return the output of the ATM module interface to the default value:
ATM#configure terminal Enter configuration commands, one per line. End with CNTL/Z. ATM(config)#interface atm0 ATM(config-if)#no atm traffic-shape rate 100 ATM(config-if)#^Z ATM#
When you enable Integrated Local Management Interface (ILMI) keepalives on a dual PHY ATM module, periodic ILMI keepalive messages are sent to the ATM switch on the active PHY. The ATM switch responds to the ILMI keepalives.
If the ATM switch fails to respond to four consecutive keepalives, the dual PHY module switches from the active PHY to the backup PHY. The ILMI keepalives feature is useful only if the dual PHY module is connected to two different ATM switches. ILMI keepalives are disabled by default.
To enable ILMI keepalives and configure the interval between messages, perform this task:
| Task | Command | |
|---|---|---|
Step 1 | Enter configuration mode. | configure terminal |
Step 2 | Select the ATM interface. | interface atm0 |
Step 3 | Enable ILMI keepalives and specify the message interval. | atm ilmi-keepalive [interval] |
Step 4 | Exit configuration mode. | Ctrl-Z |
Step 5 | Verify the output rate for the interface. | show atm ilmi-status |
![]() |
Note If you enable ILMI keepalives but do not specify the interval, the default value of 5 seconds applies. |
This example shows how to enable ILMI keepalives and configure the interval between messages to four seconds:
ATM#configure terminal Enter configuration commands, one per line. End with CNTL/Z. ATM(config)#interface atm0 ATM(config-if)#atm ilmi-keepalive 4 ATM(config-if)#^Z ATM#
The following show atm ilmi-status command displays the ILMI keepalive configuration:
ATM#show atm ilmi-status Interface : ATM0 Interface Type : Private UNI (User-side) ILMI VCC : (0, 16) ILMI Keepalive : Enabled (5 Seconds) ILMI State: UpAndNormal Peer IP Addr: 172.20.52.41 Peer IF Name: ATM12/0/0 Peer MaxVPIbits: 8 Peer MaxVCIbits: 14 Active Prefix(s) : 47.0091.8100.0000.00e0.4fac.b401 End-System Registered Address(s) : 47.0091.8100.0000.00e0.4fac.b401.00e0.4fac.b091.01(Confirmed) 47.0091.8100.0000.00e0.4fac.b401.00e0.4fac.b092.01(Confirmed) 47.0091.8100.0000.00e0.4fac.b401.00e0.4fac.b091.02(Confirmed) 47.0091.8100.0000.00e0.4fac.b401.00e0.4fac.b092.02(Confirmed) 47.0091.8100.0000.00e0.4fac.b401.00e0.4fac.b095.00(Confirmed) ATM#
To disable ILMI keepalive, perform this task:
| Task | Command | |
|---|---|---|
Step 1 | Enter configuration mode. | configure terminal |
Step 2 | Select the ATM interface. | interface atm0 |
Step 3 | Disable ILMI keepalives. | no atm ilmi-keepalive |
Step 4 | Exit configuration mode. | Ctrl-Z |
This example shows how to disable ILMI keepalives on the ATM module:
ATM#configure terminal Enter configuration commands, one per line. End with CNTL/Z. ATM(config)#interface atm0 ATM(config-if)#no atm ilmi-keepalive ATM(config-if)#^Z ATM#
The ATM modules are backward-compatible with ATM switches that support User-Network Interface (UNI) version 3.0. When the ATM module comes online, ILMI negotiates between the UNI version automatically.
If the UNI version is successfully learned through ILMI, the ATM module accepts the UNI version returned from the ATM switch. If ILMI is unable to determine the UNI version, or if ILMI is disabled, the UNI version defaults to version 3.0.
To statically configure the UNI version, perform this task:
| Task | Command | |
|---|---|---|
Step 1 | Enter configuration mode. | configure terminal |
Step 2 | Select the ATM interface. | interface atm0 |
Step 3 | Shut down the interface. | shutdown |
Step 4 | Statically configure the UNI version for the ATM interface. | atm uni-version {3.0 | 3.1} |
Step 5 | Bring up the interface. | no shutdown |
Step 6 | Exit configuration mode. | Ctrl-Z |
Step 7 | Verify the UNI version. | show interface atm0 |
This example shows how to statically configure the UNI version to version 3.0 and verify the configuration:
ATM#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
ATM(config)#interface atm0
ATM(config-if)#shutdown
ATM(config-if)#atm uni-version 3.0
ATM(config-if)#no shutdown
ATM(config-if)#^Z
ATM#show interface atm0
ATM0 is up, line protocol is up
Hardware is Catalyst 5000 ATM
MTU 1500 bytes, sub MTU 0, BW 156250 Kbit, DLY 80 usec, rely 255/255, load 1/2
55
Encapsulation ATM, loopback not set, keepalive not supported
Encapsulation(s): AAL5, PVC mode
4096 maximum active VCs, 1024 VCs per VP, 32 current VCCs
VC idle disconnect time: 300 seconds
Signalling vc = 1, vpi = 0, vci = 5
UNI Version = 3.0, Link Side = user
PHY Type : SINGLE PHY; Link Status: UP
Last input 00:00:00, output never, output hang never
Last clearing of "show interface" counters never
Queueing strategy: fifo
Output queue 0/40, 0 drops; input queue 0/75, 0 drops
5 minute input rate 1000 bits/sec, 1 packets/sec
5 minute output rate 1000 bits/sec, 1 packets/sec
870851 packets input, 116131392 bytes, 0 no buffer
Received 0 broadcasts, 0 runts, 0 giants, 0 throttles
0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored, 0 abort
705922 packets output, 83530944 bytes, 0 underruns
0 output errors, 0 collisions, 8 interface resets
0 output buffer failures, 0 output buffers swapped out
ATM#
To return the UNI version to the default (either the version returned by ILMI or UNI version 3.0, if ILMI cannot learn the UNI version or if ILMI is disabled), perform this task:
| Task | Command | |
|---|---|---|
Step 1 | Enter configuration mode. | configure terminal |
Step 2 | Select the ATM interface. | interface atm0 |
Step 3 | Shut down the interface. | shutdown |
Step 4 | Restore the default UNI version for the ATM interface (learned through ILMI or version 3.0 if ILMI cannot learn the UNI version). | no atm uni-version |
Step 5 | Bring up the interface. | no shutdown |
Step 6 | Exit configuration mode. | Ctrl-Z |
Step 7 | Verify the UNI version. | show interface atm0 |
This example shows how to return the UNI version on the ATM interface to the default:
ATM#configure terminal Enter configuration commands, one per line. End with CNTL/Z. ATM(config)#interface atm0 ATM(config-if)#shutdown ATM(config-if)#no atm uni-version ATM(config-if)#no shutdown ATM(config-if)#^Z ATM#
You can monitor activity on the ATM modules and view configuration information by entering statistics commands. See related chapters for information on how to access statistics output specific to the LANE, MPOA, or PVC protocols.
Currently, the following basic ATM statistics commands are supported:
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Thu Mar 30 16:12:17 PST 2000
Copyright 1989 - 2000©Cisco Systems Inc.