cc/td/doc/product/lan/cat6000/sw_5_3
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

Configuring the ATM Fabric Integration Module

Configuring the ATM Fabric Integration Module

This chapter describes how to configure the ATM fabric integration module. The ATM fabric integration module is supported on the Catalyst 5500 series switches only.


Note For complete information on installing the Catalyst 5000 family ATM Fabric integration module, refer to the Catalyst 5000 Family Module Installation Guide.


Note For complete syntax and usage information for the commands used in this chapter, refer to the Command Reference for your switch.

This chapter consists of these sections:

Understanding How ATM Fabric Integration Works

The ATM fabric integration module seamlessly integrates the switching fabrics of a Catalyst 5500 series switch and a LightStream 1010 ATM switch installed in the bottom slots of the Catalyst 5500 chassis.

The module consists of one external LightStream 1010 OC-12 ATM interface and one internal interface to the LightStream 1010 switching backplane. The external OC-12 ATM interface operates exactly as any an OC-12 interface on a LightStream 1010 port-adapter module (PAM) and is configured from the LightStream 1010 CLI.

Communication between the Catalyst 5500 series switch backplane and the LightStream 1010 ATM switch backplane occurs across the internal interface. You must configure the interface from both the ATM module CLI and the LightStream 1010 CLI.

ATM Fabric Integration Hardware and Software Restrictions

These guidelines apply when using the ATM fabric integration module:

Default ATM Fabric Integration Configuration

The external ATM interface of the fabric-integration module has the same default configuration as any LightStream 1010 OC-12 ATM interface. For information on the OC-12 ATM interface default configuration, refer to the LightStream 1010 ATM Switch Configuration Guide publication.

Table 6-1 shows the ATM fabric-integration module internal interface default configuration on the Catalyst 5500 side.


Table 6-1: ATM Fabric Integration Module Internal Interface Default Configuration (Catalyst 5500 Side)
Feature Default Value

LANE enable state

LANE is disabled

PVCs

ILMI and signaling PVCs are set up

Table 6-2 shows the ATM fabric-integration module internal interface default configuration on the LightStream 1010 side.


Table 6-2: ATM Fabric Integration Module Internal Interface Default Configuration (LightStream 1010 Side)
Feature Default Setting

ATM interface type

UNI

UNI version

3.0

Maximum VPI bits

8

Maximum VCI bits

14

ATM interface side

Network

ATM UNI type

Private

Framing

STS-3C

Clock source

Network-derived

Synchronous Transfer Signal (STS) stream scrambling

On

Cell payload scrambling

On

Configuring the ATM Fabric Integration Module

These sections describe how to configure the ATM fabric integration module:

Configuring the External OC-12 ATM Interface

You configure the external OC-12 interface on the ATM fabric integration module from the LightStream 1010 CLI. The following example shows how to configure the external interface as a network node interface (NNI), but the external interface on the ATM fabric integration module supports all the network connections configurable on a LightStream 1010.


Note For complete information on configuring ATM interfaces, refer to the LightStream 1010 ATM Switch Configuration Guide.

To configure the external OC-12 interface on the ATM fabric integration module, perform these tasks from the LightStream 1010 CLI:

Task Command

Step 1

Enter configuration mode.

configure terminal

Step 2

Select the ATM interface.

interface atm card/subcard/port

Step 3

Disable atm auto-configuration

no atm auto-configuration

Step 4

Configure the interface.

atm nni | uni | pvc

Step 5

Exit configuration mode.

Ctrl-Z

This example configures the external interface as a network node interface and displays the configuration:

ls1010-3#config term
Enter configuration commands, one per line.  End with CNTL/Z.
ls1010-3(config)#interface atm9/1/0
ls1010-3(config-if)#no atm auto-config
ls1010-3(config-if)#atm nni
ls1010-3(config-if)#^Z
ls1010-3#show atm interface atm9/1/0
Interface:      ATM9/1/0        Port-type:      oc12suni
IF Status:      DOWN            Admin Status:   down
Auto-config:    disabled        AutoCfgState:   not applicable
IF-Side:        Network         IF-type:        NNI
Uni-type:       not applicable  Uni-version:    not applicable
Max-VPI-bits:   8               Max-VCI-bits:   14
Max-VP:         255             Max-VC:         16383
ConfMaxSvpcVpi: 255             CurrMaxSvpcVpi: 255
ConfMaxSvccVpi: 255             CurrMaxSvccVpi: 255
ConfMinSvccVci: 35              CurrMinSvccVci: 35
Svc Upc Intent: pass            Signalling:     Enabled
ATM Address for Soft VC: 47.0091.8100.0000.0050.0b87.b401.4000.0c84.9000.00

Configured virtual links:
PVCLs SoftVCLs   SVCLs   TVCLs   PVPLs SoftVPLs   SVPLs Total-Cfgd Inst-Conns
      4        0       0       0       0        0       0          4          0
Logical ports(VP-tunnels):     0
Input cells:    0               Output cells:   0
5 minute input rate:             0 bits/sec,       0 cells/sec
5 minute output rate:            0 bits/sec,       0 cells/sec
Input AAL5 pkts: 0, Output AAL5 pkts: 0, AAL5 crc errors: 0

Configuring the Internal ATM Port from the ATM Module CLI

On the Catalyst 5500 switch side, the internal interface functions similarly to the ATM ports on the Catalyst 5000 family ATM OC-3 LANE/MPOA modules. However, there is no PHY on the internal bridge port.

You can configure the internal ATM interface (interface ATM0) exactly as you configure any ATM interface on the Catalyst 5000 family LANE/MPOA modules. For information on configuring the ATM interface, refer to the following sections:

The following commands are not available on the ATM fabric integration module:

In addition, the show controller command output does not show PHY error counters for the internal ATM port.

Configuring the Internal ATM Interface from the LightStream 1010 CLI

On the LightStream 1010 side, the internal interface functions similarly to an OC-3 ATM interface on a LightStream 1010 ATM port adapter module (PAM). However, there is no PHY on the internal bridge interface.

You can configure the internal ATM interface exactly as you configure any OC-3 ATM interface on a LightStream 1010 PAM. For information on configuring the LightStream 1010 ATM interface, refer to the LightStream 1010 ATM Switch Configuration Guide publication.


hometocprevnextglossaryfeedbacksearchhelp
Posted: Thu Mar 30 16:11:21 PST 2000
Copyright 1989 - 2000©Cisco Systems Inc.