Supplement to DOC-784482= (Text Part Number 78-4482-08)
This document provides updated information for the PA-E3 Serial Port Adapter Installation and Configuration note. Read this note before configuring the PA-E3 port adapter on the Catalyst 6000 family FlexWAN module.
This document contains the following sections:
On page v, in the "Objectives" section, add the following bullet:
On page vi, in the "Related Documentation" section, add the following bullet:
On page vii, replace the second bullet list from the bottom of the page with the following:
On page 1-1, in the "Port Adapter Overview" section, add the following bullet:
On page 1-2, replace the first two paragraphs with the following:
The one-port PA-E3 provides two network interfaces per VIP2 for Cisco 7000 series and Cisco 7500 series routers, the Catalyst 6000 family FlexWAN module in the Catalyst 6000 family switches, and the Catalyst RSM/VIP2 for the Catalyst 5000 family switches, and one high-speed interface on the Cisco 7100 series, Cisco 7200 series, and Cisco uBR7200 series routers.
The two-port PA-2E3 provides four network interfaces per VIP2 for Cisco 7000 series and Cisco 7500 series routers, the Catalyst 6000 family FlexWAN module in the Catalyst 6000 family switches, and the Catalyst RSM/VIP2 for Catalyst 5000 family switches, and two high-speed interfaces on the Cisco 7100 series, Cisco 7200 series, and Cisco uBR7200 series routers.
Also, replace the note with the following:
![]() |
Note The Catalyst RSM/VIP2, the Catalyst 6000 family FlexWAN module, and the VIP2 support online insertion and removal (OIR), but individual port adapters do not. To replace port adapters you must first remove the Catalyst RSM/VIP2, the Catalyst 6000 family FlexWAN module, or the VIP2 from the chassis and then replace port adapters as required. OIR is supported for port adapters in the Cisco 7100 series, Cisco 7200 series, and Cisco uBR7200 series routers. |
On page 1-3, add the following:
On page 1-4, in the "PA-E3 Port Adapter LEDs" section, replace the second and third bullets with the following:
On page 2-1, in the "Parts and Tools Required" section, add the following bullet:
On page 2-2, in the "Minimum Software and Hardware Requirements" section, add the following to Table 2-1:
| Platform | Recommended Minimum Cisco IOS Release |
|---|---|
Catalyst 6000 family switches with Catalyst 6000 family FlexWAN module
|
Cisco IOS Release 12.1(1)EX or later Catalyst 6000 family supervisor engine software release 5.4(1) or later |
On page 2-3, replace the note at the top of the page with the following:
![]() |
Note The Catalyst RSM/VIP2, the Catalyst 6000 family FlexWAN module, and the VIP2 support online insertion and removal (OIR), but individual port adapters do not. To replace port adapters, you must first remove the Catalyst RSM/VIP2, the Catalyst 6000 family FlexWAN module, or the VIP2 from the chassis and then replace port adapters as required. OIR is supported for port adapters in the Cisco 7100 series, Cisco 7200 series, and Cisco uBR7200 series routers. |
Also, replace the first paragraph with the following:
In the Cisco 7000 series, Cisco 7100 series, Cisco 7500 series, Cisco uBR7200 series routers and Catalyst 5000 and 6000 family switches, there are no restrictions on slot locations or sequence; however, in the Cisco 7200 series routers, there are specific configuration guidelines that must be observed for high-bandwidth port adapters.
Also, replace the third paragraph with the following:
To determine if your Cisco 7000 series, Cisco 7100 series, Cisco 7500 series, Cisco 7200 series, or Cisco uBR7200 series router, Catalyst 6000 family FlexWAN module, or Catalyst RSM/VIP2 is compatible with the PA-E3, use the show version command to display the current hardware configuration of the router, including the system software version that is currently loaded and running.
On page 8-2, in the "Identifying Port Adapter Slots and E3 Interface Port Numbers" section, add the following bullet:
On page 8-5, add the following subsection:
This section describes how to identify chassis slot, port adapter, and E3 interface port numbers on the Catalyst 6000 family FlexWAN module.
The physical port addresses specify the actual physical location of each interface port on the router interface processor end. (See Figure.) Each address is composed of a three-part number in the format module-number/port-adapter-bay/interface-port, as follows:
For example, the serial port on a PA-E3 in the first port adapter bay in a FlexWAN module installed in module slot 6 is numbered 6/0/0. (See Figure.) If you insert the PA-E3 in port adapter bay 1, this same port would be numbered 6/1/0. Port adapters can occupy either port adapter slot; there are no restrictions.

![]() |
Note The FlexWAN module physical port address uses a zero- (0-) based port address, which differs from the conventional Catalyst 6000 family one- (1-) based port address. |
![]() |
Note If you remove the FlexWAN module with the PA-E3 from module slot 6 and install it in module slot 3, the interface address becomes 3/0/0. |
On page 8-7, Step 2, add the following example:
For a Catalyst 6000 family FlexWAN module, specify the interface to configure by entering the subcommand interface serial, followed by the mod_num/bay/port (module slot number, port adapter bay number, and interface port number). The example that follows is for the interface of the first port adapter on a Catalyst 6000 family FlexWAN module in interface processor slot 3:
Router(config)# interface serial 3/0/0
On page 8-11, add the following example:
For a Catalyst 6000 family FlexWAN module, use the following example:
router# configure terminal Enter configuration commands, one per line. End with CNTL/Z. router(config)# router(config)# interface serial 3/0/0 router(config-if)# crc 32 Ctrl-z
Also, in Step 3, add the following:
On page 8-12, Step 5, add the following:
For a Catalyst 6000 family FlexWAN module, specify information that is specific to the new serial interface with the show controllers serial [type mod_num/bay/port] command, and verify that the first line of the display specifies the interface with the correct slot number.
On page 8-16, add the following example:
For a Catalyst 6000 family FlexWAN module, the show interfaces type mod_num/bay/port command displays status information (including the physical slot and port address) for the interfaces you specify. In this example, a one-port PA-E3 serial port adapter-configured Catalyst 6000 family FlexWAN module is in chassis slot 3, in port adapter slot 0.
router# show interfaces serial 3/0/0
Serial3/0/0/ is down, line protocol is down
Hardware is E3
MTU 1500 bytes, BW 1984 Kbit, DLY 20000 usec,
reliability 255/255, txload 1/255, rxload 1/255
Encapsulation HDLC, crc 16, loopback not set
Keepalive not set
Last input never, output never, output hang never
Last clearing of "show interface" counters never
Queueing strategy: fifo
Output queue 0/40, 0 drops; input queue 0/75, 0 drops
5 minute input rate 0 bits/sec, 0 packets/sec
5 minute output rate 0 bits/sec, 0 packets/sec
0 packets input, 0 bytes, 0 no buffer
Received 0 broadcasts, 0 runts, 0 giants, 0 throttles
0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored, 0 abort
0 packets output, 0 bytes, 0 underruns
0 output errors, 0 collisions, 2 interface resets
0 output buffer failures, 0 output buffers swapped out
0 carrier transitions alarm present
Timeslot(s) Used:1-31, Transmitter delay is 0 flags, transmit queue length 999
router#
On page 8-15, add the following:
The example that follows is for a port adapter in a Catalyst 6000 family FlexWAN module:
Router(config)# show version Cisco Internetwork Operating System Software IOS (tm) MSFC Software (C6MSFC-JSV-M), Experimental Version 12.1(20000209:134547) [amcrae-cosmos_e_nightly 163] Copyright (c) 1986-2000 by cisco Systems, Inc. Compiled Wed 09-Feb-00 07:10 by Image text-base: 0x60008900, data-base: 0x6140E000 ROM: System Bootstrap, Version 12.0(3)XE, RELEASE SOFTWARE const-uut uptime is 5 minutes System returned to ROM by reload System image file is "bootflash:c6msfc-jsv-mz.Feb9" cisco Cat6k-MSFC (R5000) processor with 122880K/8192K bytes of memory. Processor board ID SAD03457061 R5000 CPU at 200Mhz, Implementation 35, Rev 2.1, 512KB L2 Cache Last reset from power-on Channelized E1, Version 1.0. Bridging software. X.25 software, Version 3.0.0. SuperLAT software (copyright 1990 by Meridian Technology Corp). TN3270 Emulation software. Primary Rate ISDN software, Version 1.1. 6 FlexWAN controllers (13 Serial)(8 E1)(8 T1)(2 HSSI)(2 ATM)(1 Channelized T3)(1 Channelized E3)(2 POS). 1 Virtual Ethernet/IEEE 802.3 interface(s) 17 Serial network interface(s) 2 HSSI network interface(s) 2 ATM network interface(s) 2 Packet over SONET network interface(s) 1 Channelized T3 port(s) 1 Channelized E3 port(s) 123K bytes of non-volatile configuration memory. 4096K bytes of packet SRAM memory. 16384K bytes of Flash internal SIMM (Sector size 256K). Configuration register is 0x1
On page 8-17, add the following:
The following example shows a one-port PA-E3 serial port adapter in chassis slot 3 on a Catalyst 6000 family FlexWAN module:
router# show diag
Slot 3: Logical_index 11
Board is analyzed ipc ready FlexWAN controller
Slot database information:
Flags: 0x2004 Insertion time: unknown
CWAN Controller Memory Size: Unknown
PA Bay 1 Information:
CE3 PA, 1 port
EEPROM format version 0
HW rev 0.00, Board revision UNKNOWN
Serial number: 00000000 Part number: 00-0000-00
Cisco Connection Online (CCO) is Cisco Systems' primary, real-time support channel. Maintenance customers and partners can self-register on CCO to obtain additional information and services.
Available 24 hours a day, 7 days a week, CCO provides a wealth of standard and value-added services to Cisco's customers and business partners. CCO services include product information, product documentation, software updates, release notes, technical tips, the Bug Navigator, configuration notes, brochures, descriptions of service offerings, and download access to public and authorized files.
CCO serves a wide variety of users through two interfaces that are updated and enhanced simultaneously: a character-based version and a multimedia version that resides on the World Wide Web (WWW). The character-based CCO supports Zmodem, Kermit, Xmodem, FTP, and Internet e-mail, and it is excellent for quick access to information over lower bandwidths. The WWW version of CCO provides richly formatted documents with photographs, figures, graphics, and video, as well as hyperlinks to related information.
You can access CCO in the following ways:
For a copy of CCO's Frequently Asked Questions (FAQ), contact cco-help@cisco.com. For additional information, contact cco-team@cisco.com.
![]() |
Note If you are a network administrator and need personal technical assistance with a Cisco product that is under warranty or covered by a maintenance contract, contact Cisco's Technical Assistance Center (TAC) at 800 553-2447, 408 526-7209, or tac@cisco.com. To obtain general information about Cisco Systems, Cisco products, or upgrades, contact 800 553-6387, 408 526-7208, or cs-rep@cisco.com |
Cisco documentation and additional literature are available in a CD-ROM package, which ships with your product. The Documentation CD-ROM, a member of the Cisco Connection Family, is updated monthly. Therefore, it might be more current than printed documentation. To order additional copies of the Documentation CD-ROM, contact your local sales representative or call customer service. The CD-ROM package is available as a single package or as an annual subscription. You can also access Cisco documentation on the World Wide Web at http://www.cisco.com, http://www-china.cisco.com, or http://www-europe.cisco.com.
If you are reading Cisco product documentation on the World Wide Web, you can submit comments electronically. Click Feedback in the toolbar and select Documentation. After you complete the form, click Submit to send it to Cisco. We appreciate your comments.

![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Sun Mar 5 13:27:53 PST 2000
Copyright 1989 - 2000©Cisco Systems Inc.