| Item | Specification |
|---|---|
| Environmental |
|
| 32°F (0°C) to 104°F (40°C) |
| -40°F (-40°C) to 158°F (70°C) |
10% to 90% | |
| 5% to 95% |
| Sea level to 10,000 ft. (3050 m) |
| Switching Components | |
Supervisor Engine 1: 150-MHz IDT R4700 RISC | |
| Memory |
|
| DRAM: 64 MB; Flash (onboard): 16 MB; PC Flash: 16 MB or 24 MB; NVRAM: 512 KB |
| Physical Characteristics |
|
20.1 x 17.25 x 18.4 in. (51.1 x 43.1 x 46.0 cm) | |
| Chassis only: 45 lb (20.41 kg) Chassis fully configured with 1 supervisor engine, 5 switching modules, and 2 power supplies: 115 lb (52.15 kg) |
| 1000W AC Power Supply |
|
| 1000W maximum |
| 100 to 240VAC wide input with power factor corrector |
| 50 to 60 Hz |
| +3.3V @ 15A, +5V @5A, +12V @ 6A, +42V @ 21.34A |
| 1300W AC and DC Power Supplies |
|
1300W maximum AC-input; 1360W DC-input | |
1800W (total input power) or 1.8 KVA | |
6140 BTUs1/hr | |
| 100 to 240 VAC wide input with power factor corrector |
| -48 VDC to -60 VDC continuous |
50 to 60 Hz | |
| Recommend 8 AWG 90ºC copper conductors |
| Rated 16-8A Maximum power budget: 17.6A @ 100 VAC, 60 Hz; |
| Rated 40A Maximum power budget: 43A @ 42 VDC; 38A @ 48 VDC; 30A @ 60 VDC with chassis fully configured |
| +3.3V @ 15A, +5V @ 5A, +12V @ 6A, +42V @ 27.46A |
| +3.3V @ 15A, +5V @ 5A, +12V @ 6A, +42V @ 28.84A |
| 2500W AC Power Supply |
|
| 1300W @ 85 to 132 VAC |
| 12000 BTU/hour (170 to 264 VAC operation) |
| 100 to 240 VAC wide input with power factor corrector |
| 47 to 63 Hz |
| 17.6A @ 100 VAC and 1300W output |
| +3.3V @ 15A, +5V @ 5A, +12V @ 10A, +42V @ 55.5A |
| Airflow | 200 lfm2 through system fan assembly |
| Agency Approvals Compliance Safety EMC3 | |
Catalyst 6009 and 6509 switch specifications are provided in Table A-2.
| Item | Specification |
|---|---|
| Environmental |
|
| 32°F (0°C) to 104°F (40°C) |
| -40°F (-40°C) to 158°F (70°C) |
10% to 90% | |
| 5% to 95% |
| Sea level to 10,000 ft. (3050 m) |
| Switching Components | |
Supervisor Engine 1: 150-MHz IDT R4700 RISC | |
| Memory |
|
| DRAM: 64 MB; Flash (onboard): 16 MB; PCMCIA Flash: 16 MB or 24 MB; NVRAM: 512 KB |
| Physical Characteristics |
|
25.5 x 17.25 x 18.4 in. (64.8 x 43.1 x 46.0 cm) | |
Chassis only: 55 lb (24.9 kg) Chassis fully configured with 1 supervisor engine, 8 switching modules, and 2 power supplies: 135 lb (61.2 kg) | |
| 1300W AC and DC Power Supplies | |
1300W maximum AC-input; 1360W DC-input | |
1800W | |
6140 Btus1/hr | |
| 100 to 240 VAC wide input with power factor corrector |
-48 VDC to -60 VDC continuous | |
50 to 60 Hz | |
| Recommend 8 AWG 90ºC copper conductors |
| Rated 16-8A Maximum power budget: 17.6A @ 100 VAC, 60 Hz; |
| Rated 40A Maximum power budget: 43A @ 42 VDC; 38A @ 48 VDC; 30A @ 60 VDC with chassis fully configured |
| +3.3V @ 15A, +5V @ 5A, +12V @ 6A, +42V @ 27.46A |
| +3.3V @ 15A, +5V @ 5A, +12V @ 6A, +42V @ 28.84A |
| 2500W AC Power Supply |
|
| 1300W @ 85 to 132 VAC |
| 12000 BTU/hour (170 to 264 VAC operation) |
| 100 to 240 VAC wide input with power factor corrector |
| 47 to 63 Hz |
| 17.6A @ 100 VAC and 1300W output |
| +3.3V @ 15A, +5V @ 5A, +12V @ 10A, +42V @ 55.5A |
| Airflow | 200 lfm2 through system fan assembly |
| Agency Approvals Compliance Safety EMC3 | |
Catalyst 6509-NEB specifications are provided in Table A-3.
| Item | Specification |
|---|---|
| Environmental |
|
| 32°F (0°C) to 104°F (40°C) |
| -40°F (-40°C) to 158°F (70°C) |
10% to 90% | |
| 5% to 95% |
| Sea level to 10,000 ft. (3050 m) |
| Switching Components | |
Supervisor Engine 1: 150-MHz IDT R4700 RISC | |
| Memory |
|
| DRAM: 64 MB; Flash (onboard): 16 MB; PCMCIA Flash: 16 MB or 24 MB; NVRAM: 512 KB |
| Physical Characteristics |
|
| 33.5 x 17.25 x 18.1 inches (85.1 x 43.1 x 46 cm) |
| Chassis only: 55 lb (24.9 kg) Chassis fully configured with 1 supervisor engine, 8 switching modules, and 2 power supplies: 135 lb (61.2 kg) |
| 1300W AC and DC Power Supplies | |
1300W maximum AC-input; 1360W DC-input | |
1800W | |
6140 Btus1/hr | |
| 100 to 240 VAC wide input with power factor corrector |
-48 VDC to -60 VDC continuous | |
50 to 60 Hz | |
| Recommend 8 AWG 90ºC copper conductors |
| Rated 16-8A Maximum power budget: 17.6A @ 100 VAC, 60 Hz; |
| Rated 40A Maximum power budget: 43A @ 42 VDC; 38A @ 48 VDC; 30A @ 60 VDC with chassis fully configured |
| +3.3V @ 15A, +5V @ 5A, +12V @ 6A, +42V @ 27.46A |
| +3.3V @ 15A, +5V @ 5A, +12V @ 6A, +42V @ 28.84A |
| 2500W AC Power Supply |
|
| 1300W @ 85 to 132 VAC |
| 12000 BTU/hour (170 to 264 VAC operation) |
| 100 to 240 VAC wide input with power factor corrector |
| 47 to 63 Hz |
| 17.6A @ 100 VAC and 1300W output |
| +3.3V @ 15A, +5V @ 5A, +12V @ 10A, +42V @ 55.5A |
| Airflow | 200 lfm2 through system fan assembly |
| Agency Approvals Compliance Safety EMC3 | |
![]()
![]()
![]()
![]()
![]()
![]()
![]()