cc/td/doc/product/lan/cat6000/6000hw
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

Specifications

Specifications

This appendix provides the technical specifications for the Catalyst 6000 family switches:

Refer to the Catalyst 6000 Family Module Installation Guide for module and interface port specifications.

Catalyst 6006 and 6506 Switches

Catalyst 6006 and 6506 switch specifications are provided in Table A-1.


Table A-1: Catalyst 6006 Switch and Catalyst 6506 Switch Specifications
Item Specification
Environmental

Temperature, ambient operating

32°F (0°C) to 104°F (40°C)

Temperature, ambient nonoperating and storage

-40°F (-40°C) to 158°F (70°C)

Humidity (RH), ambient (noncondensing) operating

10% to 90%

Humidity (RH), ambient (noncondensing) nonoperating and storage

5% to 95%

Altitude, operating and nonoperating

Sea level to 10,000 ft. (3050 m)

Switching Components
Microprocessor

Supervisor Engine 1: 150-MHz IDT R4700 RISC

Memory

Supervisor Engine 1

DRAM: 64 MB; Flash (onboard): 16 MB; PC Flash: 16 MB or 24 MB; NVRAM: 512 KB

Physical Characteristics

Dimensions (H x W x D)

20.1 x 17.25 x 18.4 in. (51.1 x 43.1 x 46.0 cm)
Chassis depth including cable guide is 21.64 in. (55.0 cm)

Weight

Chassis only: 45 lb (20.41 kg)

Chassis fully configured with 1 supervisor engine, 5 switching modules, and 2 power supplies: 115 lb (52.15 kg)

1000W AC Power Supply

Power supply output capacity

1000W maximum

AC-input voltage

100 to 240VAC wide input with power factor corrector

AC frequency

50 to 60 Hz

Power supply output

+3.3V @ 15A, +5V @5A, +12V @ 6A, +42V @ 21.34A

1300W AC and DC Power Supplies

Power supply output capacity

1300W maximum AC-input; 1360W DC-input

System power dissipation (AC and DC supplies)

1800W (total input power) or 1.8 KVA

System heat dissipation (AC and DC supplies)

6140 BTUs1/hr

AC-input voltage

100 to 240 VAC wide input with power factor corrector

DC-input voltage
Typical range (U.S. and Canada)
Typical range (International)

-48 VDC to -60 VDC continuous
-48 VDC (nominal) -56 VDC (high) -40.5 VDC (low)
-60 VDC (nominal) -72 VDC (high) -55 VDC (low)

AC frequency

50 to 60 Hz

DC power-cable wire gauge

Recommend 8 AWG 90ºC copper conductors

AC current

Rated 16-8A

Maximum power budget: 17.6A @ 100 VAC, 60 Hz;
14.6A @ 115 VAC, 60 Hz; 7A @ 230 VAC, 50 Hz with chassis fully configured

DC current

Rated 40A

Maximum power budget: 43A @ 42 VDC; 38A @ 48 VDC; 30A @ 60 VDC with chassis fully configured

Power supply output (AC supply)

+3.3V @ 15A, +5V @ 5A, +12V @ 6A, +42V @ 27.46A

Power supply output (DC supply)

+3.3V @ 15A, +5V @ 5A, +12V @ 6A, +42V @ 28.84A

2500W AC Power Supply

Power supply output capacity

1300W @ 85 to 132 VAC
2500W @ 170 to 264 VAC

System heat dissipation

12000 BTU/hour (170 to 264 VAC operation)

AC-input voltage

100 to 240 VAC wide input with power factor corrector

AC frequency

47 to 63 Hz

AC current

17.6A @ 100 VAC and 1300W output
17.6A @ 200 VAC and 2500W output

Power supply output

+3.3V @ 15A, +5V @ 5A, +12V @ 10A, +42V @ 55.5A

Airflow

200 lfm2 through system fan assembly

Agency Approvals
  Compliance
 
  Safety
 
 
  E
MC3

 
CE4 Marking
 
UL5 1950, CSA6-C22.2 No. 950, EN7 60950, IEC8 950, TS9 001, AS/NZS10 3260
 
FCC11 Part 15 (CFR12 47) Class A, ICES13-003 Class A, EN55022 Class A, CISPR22 Class A, AS/NZS 3548 Class A, and VCCI Class A with UTP14 cables
 
EN55022 Class B, CISPR22 Class B, AS/NZS 3548 Class B, and VCCI15 Class B with FTP16 cables

1Btus = British thermal units.
2lfm = linear feet per minute.
3EMC = electromagnetic compatibility.
4CE = European Compliance.
5UL = Underwriters Laboratory.
6CSA = Canadian Standards Association.
7EN = European Norm.
8IEC = International Electrotechnical Commission.
9TS = Technical Specification.
10AS/NZS = Standards Australia/Standards New Zealand.
11FCC = Federal Communications Commission.
12CFR = Code of Federal Regulations.
13ICES = Interference-Causing Equipment Standard.
14UTP = unshielded twisted-pair.
15VCCI = Voluntary Control Council for Information Technology Equipment.
16FTP = foil twisted-pair.

Catalyst 6009 and 6509 Switches

Catalyst 6009 and 6509 switch specifications are provided in Table A-2.


Table A-2: Catalyst 6009 Switch and Catalyst 6509 Switch Specifications
Item Specification
Environmental

Temperature, ambient operating

32°F (0°C) to 104°F (40°C)

Temperature, ambient nonoperating and storage

-40°F (-40°C) to 158°F (70°C)

Humidity (RH), ambient (noncondensing) operating

10% to 90%

Humidity (RH), ambient (noncondensing) nonoperating and storage

5% to 95%

Altitude, operating and nonoperating

Sea level to 10,000 ft. (3050 m)

Switching Components
Microprocessor

Supervisor Engine 1: 150-MHz IDT R4700 RISC

Memory

Supervisor Engine 1

DRAM: 64 MB; Flash (onboard): 16 MB; PCMCIA Flash: 16 MB or 24 MB; NVRAM: 512 KB

Physical Characteristics

Dimensions (H x W x D)

25.5 x 17.25 x 18.4 in. (64.8 x 43.1 x 46.0 cm)
Chassis depth including cable guide is 21.64 in. (55.0 cm)

Weight

Chassis only: 55 lb (24.9 kg)

Chassis fully configured with 1 supervisor engine, 8 switching modules, and 2 power supplies: 135 lb (61.2 kg)

1300W AC and DC Power Supplies
Power supply output capacity

1300W maximum AC-input; 1360W DC-input

System power dissipation (AC and DC supplies)

1800W

System heat dissipation (AC and DC supplies)

6140 Btus1/hr

AC-input voltage

100 to 240 VAC wide input with power factor corrector

DC-input voltage
Typical range (U.S. and Canada)
Typical range (International)

-48 VDC to -60 VDC continuous
-48 VDC (nominal) -56 VDC (high) -40.5 VDC (low)
-60 VDC (nominal) -72 VDC (high) -55 VDC (low)

AC frequency

50 to 60 Hz

DC power-cable wire gauge

Recommend 8 AWG 90ºC copper conductors

AC current

Rated 16-8A

Maximum power budget: 17.6A @ 100 VAC, 60 Hz;
14.6A @ 115 VAC, 60 Hz; 7A @ 230 VAC, 50 Hz with chassis fully configured

DC current

Rated 40A

Maximum power budget: 43A @ 42 VDC; 38A @ 48 VDC; 30A @ 60 VDC with chassis fully configured

Power supply output (AC supply)

+3.3V @ 15A, +5V @ 5A, +12V @ 6A, +42V @ 27.46A

Power supply output (DC supply)

+3.3V @ 15A, +5V @ 5A, +12V @ 6A, +42V @ 28.84A

2500W AC Power Supply

Power supply output capacity

1300W @ 85 to 132 VAC
2500W @ 170 to 264 VAC

System heat dissipation

12000 BTU/hour (170 to 264 VAC operation)

AC-input voltage

100 to 240 VAC wide input with power factor corrector

AC frequency

47 to 63 Hz

AC current

17.6A @ 100 VAC and 1300W output
17.6A @ 200 VAC and 2500W output

Power supply output

+3.3V @ 15A, +5V @ 5A, +12V @ 10A, +42V @ 55.5A

Airflow

200 lfm2 through system fan assembly

Agency Approvals
  Compliance
 
  Safety
 
 
  E
MC3

 
CE4 Marking
 
UL5 1950, CSA6-C22.2 No. 950, EN7 60950, IEC8 950, TS9 001, AS/NZS10 3260
 
FCC11 Part 15 (CFR12 47) Class A, ICES13-003 Class A, EN55022 Class A, CISPR22 Class A, AS/NZS 3548 Class A, and VCCI Class A with UTP14 cables
 
EN55022 Class B, CISPR22 Class B, AS/NZS 3548 Class B, and VCCI15 Class B with FTP16 cables

1Btus = British thermal units.
2lfm = linear feet per minute.
3EMC = electromagnetic compatibility.
4CE = European Compliance.
5UL = Underwriters Laboratory.
6CSA = Canadian Standards Association.
7EN = European Norm.
8IEC = International Electrotechnical Commission.
9TS = Technical Specification.
10AS/NZS = Standards Australia/Standards New Zealand.
11FCC = Federal Communications Commission.
12CFR = Code of Federal Regulations.
13ICES = Interference-Causing Equipment Standard.
14UTP = unshielded twisted-pair.
15VCCI = Voluntary Control Council for Information Technology Equipment.
16FTP = foil twisted-pair.

Catalyst 6509-NEB Switch

Catalyst 6509-NEB specifications are provided in Table A-3.


Table A-3: Catalyst 6509-NEB Switch Specifications
Item Specification
Environmental

Temperature, ambient operating

32°F (0°C) to 104°F (40°C)

Temperature, ambient nonoperating and storage

-40°F (-40°C) to 158°F (70°C)

Humidity (RH), ambient (noncondensing) operating

10% to 90%

Humidity (RH), ambient (noncondensing) nonoperating and storage

5% to 95%

Altitude, operating and nonoperating

Sea level to 10,000 ft. (3050 m)

Switching Components
Microprocessor

Supervisor Engine 1: 150-MHz IDT R4700 RISC

Memory

Supervisor Engine 1

DRAM: 64 MB; Flash (onboard): 16 MB; PCMCIA Flash: 16 MB or 24 MB; NVRAM: 512 KB

Physical Characteristics

Dimensions (H x W x D)

33.5 x 17.25 x 18.1 inches (85.1 x 43.1 x 46 cm)

Weight

Chassis only: 55 lb (24.9 kg)

Chassis fully configured with 1 supervisor engine, 8 switching modules, and 2 power supplies: 135 lb (61.2 kg)

1300W AC and DC Power Supplies
Power supply output capacity

1300W maximum AC-input; 1360W DC-input

System power dissipation (AC and DC supplies)

1800W

System heat dissipation (AC and DC supplies)

6140 Btus1/hr

AC-input voltage

100 to 240 VAC wide input with power factor corrector

DC-input voltage
Typical range (U.S. and Canada)
Typical range (International)

-48 VDC to -60 VDC continuous
-48 VDC (nominal) -56 VDC (high) -40.5 VDC (low)
-60 VDC (nominal) -72 VDC (high) -55 VDC (low)

AC frequency

50 to 60 Hz

DC power-cable wire gauge

Recommend 8 AWG 90ºC copper conductors

AC current

Rated 16-8A

Maximum power budget: 17.6A @ 100 VAC, 60 Hz;
14.6A @ 115 VAC, 60 Hz; 7A @ 230 VAC, 50 Hz with chassis fully configured

DC current

Rated 40A

Maximum power budget: 43A @ 42 VDC; 38A @ 48 VDC; 30A @ 60 VDC with chassis fully configured

Power supply output (AC supply)

+3.3V @ 15A, +5V @ 5A, +12V @ 6A, +42V @ 27.46A

Power supply output (DC supply)

+3.3V @ 15A, +5V @ 5A, +12V @ 6A, +42V @ 28.84A

2500W AC Power Supply

Power supply output capacity

1300W @ 85 to 132 VAC
2500W @ 170 to 264 VAC

System heat dissipation

12000 BTU/hour (170 to 264 VAC operation)

AC-input voltage

100 to 240 VAC wide input with power factor corrector

AC frequency

47 to 63 Hz

AC current

17.6A @ 100 VAC and 1300W output
17.6A @ 200 VAC and 2500W output

Power supply output

+3.3V @ 15A, +5V @ 5A, +12V @ 10A, +42V @ 55.5A

Airflow

200 lfm2 through system fan assembly

Agency Approvals
  Compliance
 
  Safety
 
 
  E
MC3

 
CE4 Marking
 
UL5 1950, CSA6-C22.2 No. 950, EN7 60950, IEC8 950, TS9 001, AS/NZS10 3260
 
FCC11 Part 15 (CFR12 47) Class A, ICES13-003 Class A, EN55022 Class A, CISPR22 Class A, AS/NZS 3548 Class A, and VCCI Class A with UTP14 cables
 
EN55022 Class B, CISPR22 Class B, AS/NZS 3548 Class B, and VCCI15 Class B with FTP16 cables

1Btus = British thermal units.
2lfm = linear feet per minute.
3EMC = electromagnetic compatibility.
4CE = European Compliance.
5UL = Underwriters Laboratory.
6CSA = Canadian Standards Association.
7EN = European Norm.
8IEC = International Electrotechnical Commission.
9TS = Technical Specification.
10AS/NZS = Standards Australia/Standards New Zealand.
11FCC = Federal Communications Commission.
12CFR = Code of Federal Regulations.
13ICES = Interference-Causing Equipment Standard.
14UTP = unshielded twisted-pair.
15VCCI = Voluntary Control Council for Information Technology Equipment.
16FTP = foil twisted-pair.


hometocprevnextglossaryfeedbacksearchhelp
Posted: Sun Jun 11 03:18:52 PDT 2000
Copyright 1989 - 2000©Cisco Systems Inc.