cc/td/doc/product/lan/cat5000/rel_5_5
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

show multicast protocols status
show multicast router
show netstat
show ntp
show port
show port auxiliaryvlan
show port broadcast
show port capabilities
show port cdp
show port channel
show port counters
show port filter
show port flowcontrol
show port ifindex
show port negotiation
show port protocol
show port qos
show port security
show port security statistics
show port status
show proc
show protocolfilter
show qos info
show qos ip
show qos mac-cos
show qos policy-source
show qos router-mac
show qos statistics
show radius
show rgmp group

2

show multicast protocols status

Use the show multicast protocols status command to display multicast protocol configuration status.

show multicast protocols status

Syntax Description

This command has no keywords or arguments.

Defaults

This command has no default setting.

Command Types

Switch command.

Command Modes

Normal.

Examples

This example show how to display the multicast protocol configuration:

Console> show multicast protocols status
CGMP disabled
IGMP enabled
IGMP fastleave disabled
RGMP enabled
GMRP disabled
Console> (enable) 

Related Commands

clear multicast router
set multicast router
show multicast router
show multicast group count

show multicast router

Use the show multicast router command to display which ports have CGMP-capable routers assigned to them.

show multicast router [cgmp | igmp | rgmp] [mod_num/port_num] [vlan_id]

Syntax Description

cgmp

(Optional) Keyword that specifies to display only the configuration information learned through CGMP.

igmp

(Optional) Keyword that specifies to display only the configuration information learned through IGMP.

rgmp

(Optional) Keyword that specifies to display only the configuration information learned through RGMP.

mod_num

(Optional) Number of the module.

port_num

(Optional) Number of the port on the module.

vlan_id

(Optional) Number of the VLAN.

Defaults

This command has no default setting.

Command Types

Switch command.

Command Modes

Normal.

Usage Guidelines

The igmp keyword is not supported by the Catalyst 4000 family and 2948G switches.

The Catalyst 2948G and 2980G switches are fixed configuration switches. Ports are located on module 2 for the 2948G and on modules 2 and 3 for the 2980G; for this reason, if you enter mod_num/port_num 1/N, an error message will be displayed.

Examples

This example show how to display the multicast router configuration:

Console> show multicast router
Port       Vlan
---------- ----------------
 
Total Number of Entries = 0
'*' - Configured
'+' - RGMP-capable
Console> (enable) 
 

This example show how to display the multicast router configuration for VLAN 99:

Console> show multicast router 99
Port       Vlan
---------- ----------------
 
Total Number of Entries = 0
'*' - Configured
Console> 
 

This example shows how to display only the configuration information learned through CGMP:

Console> show multicast router cgmp
CMGP Feature is enabled.
Console> 

Table 2-38 describes the fields in the show multicast router command output.


Table 2-38: show multicast router Command Output Fields
Field Description

Port

Port through which a multicast router can be reached.

Vlan

VLAN associated with the port.

*

Status of whether the port was manually configured as a multicast router port.

+

States whether the port is RGMP capable.

CGMP enabled

Status of whether CGMP is enabled or disabled.

IGMP enabled

Status of whether IGMP is enabled or disabled.

Total Number of Entries

Total number of entries in the table that match the criteria specified by the command.

Related Commands

clear multicast router
set cgmp
set igmp
set igmp fastleave
set multicast router
show multicast group count

show netstat

Use the show netstat command to display the currently active network connections and to list statistics for the various protocols in the TCP/IP.

show netstat [tcp | udp | ip | icmp | routes | stats | interfaces]

Syntax Description

tcp

(Optional) Keyword that specifies to show TCP statistics.

udp

(Optional) Keyword that specifies to show UDP statistics.

ip

(Optional) Keyword that specifies to show IP statistics.

icmp

(Optional) Keyword that specifies to show ICMP statistics.

routes

(Optional) Keyword that specifies to show the IP routing table.

stats

(Optional) Keyword that specifies to show all statistics for TCP, UDP, IP, and ICMP.

interfaces

(Optional) Keyword that specifies to show interface statistics.

Defaults

This command has no default setting.

Command Types

Switch command.

Command Modes

Normal.

Usage Guidelines

Counter information for me1 is viewed by entering the show netstat interfaces command.

Examples

This example shows how to display the current active network connections:

Console> show netstat
Active Internet connections (including servers)
Proto Recv-Q Send-Q  Local Address          Foreign Address        (state)
tcp        0    128  172.20.25.142.23       171.68.10.75.44720     ESTABLISHED
tcp        0      0  *.7161                 *.*                    LISTEN
tcp        0      0  *.23                   *.*                    LISTEN
udp        0      0  *.*                    *.*
udp        0      0  *.161                  *.*
udp        0      0  *.123                  *.*
Console>
 

This example shows how to display TCP statistics:

Console> show netstat tcp
tcp:
        5122 packets sent
                4642 data packets (102292 bytes)
                28 data packets (6148 bytes) retransmitted
                434 ack-only packets (412 delayed)
                0 URG only packets
                0 window probe packets
                1 window update packet
                17 control packets
        7621 packets received
                4639 acks (for 103883 bytes)
                69 duplicate acks
                0 acks for unsent data
                3468 packets (15367 bytes) received in-sequence
                12 completely duplicate packets (20 bytes)
                0 packets with some dup. data (0 bytes duped)
                4 out-of-order packets (0 bytes)
                0 packets (0 bytes) of data after window
                0 window probes
                0 window update packets
                0 packets received after close
                0 discarded for bad checksums
                0 discarded for bad header offset fields
                0 discarded because packet too short
        6 connection requests
        6 connection accepts
        10 connections established (including accepts)
        11 connections closed (including 1 drop)
        2 embryonic connections dropped
        4581 segments updated rtt (of 4600 attempts)
        28 retransmit timeouts
                0 connections dropped by rexmit timeout
        0 persist timeouts
        66 keepalive timeouts
                63 keepalive probes sent
                3 connections dropped by keepalive
Console>

Table 2-39 describes the fields in the show netstat tcp command output.


Table 2-39: show netstat tcp Command Output Fields
Field Description

packets sent

Total number of TCP packets sent.

data packets (bytes)

Number of TCP data packets sent and the size of those packets in bytes.

data packets (bytes) retransmitted

Number of TCP data packets retransmitted and the size of those packets in bytes.

ack-only packets (delayed)

Number of TCP acknowledgment-only packets sent and the number of those packets delayed.

packets received

Total number of TCP packets received.

acks (for x bytes)

Number of TCP acknowledgments received and the total bytes acknowledged.

duplicate acks

Number of duplicate TCP acknowledgments received.

acks for unsent data

Number of TCP acknowledgments received for data that was not sent.

packets (bytes) received in-sequence

Number of TCP packets (and the size in bytes) received in sequence.

completely duplicate packets (bytes)

Number of duplicate TCP packets (and the size in bytes) received.

packets with some dup. data (bytes duped)

Number of TCP packets received with duplicate data (and the number of bytes of duplicated data).

out-of-order packets (bytes)

Number of out-of-order TCP packets (and the size in bytes) received.

packets (bytes) of data after window

Number of TCP packets (and the size in bytes) received outside of the specified data window.

discarded for bad checksums

Number of TCP packets received and discarded that failed the checksum.

discarded because packet too short

Number of TCP packets received and discarded that were truncated.

connection requests

Total number of TCP connection requests sent.

connection accepts

Total number of TCP connection accepts sent.

connections established (including accepts)

Total number of TCP connections established, including those for which a connection accept was sent.

connections closed (including x drops)

Total number of TCP connections closed, including dropped connections.

retransmit timeouts

Number of timeouts that occurred when a retransmission was attempted.

connections dropped by rexmit timeout

Number of connections dropped due to retransmission timeouts.

keepalive timeouts

Number of keepalive timeouts that occurred.

keepalive probes sent

Number of TCP keepalive probes sent.

connections dropped by keepalive

Number of connections dropped.

This example shows how to display UDP statistics:

Console> show netstat udp
udp:
        0 incomplete headers
        0 bad data length fields
        0 bad checksums
        0 socket overflows
        1116 no such ports
Console>

Table 2-40 describes the fields in the show netstat udp command output.


Table 2-40: show netstat udp Command Output Fields
Field Description

incomplete headers

Number of UDP packets received with incomplete packet headers.

bad data length fields

Number of UDP packets received with a data length field that did not match the actual length of the packet payload.

bad checksums

Number of UDP packets received that failed the checksum.

socket overflows

Number of socket overflows.

no such ports

Number of UDP packets received destined for nonexistent ports.

This example shows how to display IP statistics:

Console> show netstat ip
ip:
        76894 total packets received
        0 bad header checksums
        0 with size smaller than minimum
        0 with data size < data length
        0 with header length < data size
        0 with data length < header length
        0 fragments received
        0 fragments dropped (dup or out of space)
        0 fragments dropped after timeout
        0 packets forwarded
        0 packets not forwardable
        0 redirects sent
Console>

Table 2-41 describes the fields in the show netstat ip command output.


Table 2-41: show netstat ip Command Output Fields
Field Description

total packets received

Total number of IP packets received.

bad header checksums

Number of received IP packets that failed the checksum.

with size smaller than minimum

Number of received IP packets that were smaller than the minimum IP packet size.

fragments received

Number of IP packet fragments received.

fragments dropped (dup or out of space)

Number of received IP packet fragments that were dropped because of duplicate data or buffer overflow.

fragments dropped after timeout

Number of received IP packet fragments that were dropped.

packets forwarded

Number of forwarded IP packets.

packets not forwardable

Number of IP packets that the switch did not forward.

This example shows how to display ICMP statistics:

Console> show netstat icmp
icmp:
        Redirect enabled
        0 calls to icmp_error
        0 errors not generated 'cuz old message was icmp
        Output histogram:
                echo reply: 1001
        1 message with bad code fields
        0 messages < minimum length
        0 bad checksums
        0 messages with bad length
        Input histogram:
                echo reply: 12
                destination unreachable: 3961
                echo: 1001
        1001 message responses generated
Console>

Table 2-42 describes the fields in the show netstat icmp command output.


Table 2-42: show netstat icmp Command Output Fields
Field Description

Redirect enabled

Status of whether ICMP redirection is enabled or disabled.

Output histogram

Frequency distribution statistics for output ICMP packets.

echo reply

Number of output echo reply ICMP packets.

messages with bad code fields

Number of ICMP packets with an invalid code field.

messages < minimum length

Number of ICMP packets with less than the minimum packet length.

bad checksums

Number of ICMP packets that failed the checksum.

messages with bad length

Number of ICMP packets with an invalid length.

Input histogram

Frequency distribution statistics for input ICMP packets.

echo reply

Number of input echo reply ICMP packets.

destination unreachable

Number of input destination unreachable ICMP packets.

echo

Number of input echo ICMP packets.

message responses generated

Number of ICMP message responses the system generated.

This example shows how to display the IP routing table:

Console> show netstat routes
DESTINATION     GATEWAY         FLAGS   USE             INTERFACE
default         172.16.1.201    UG      6186            sc0
172.16.0.0      172.16.25.142   U       6383            sc0
default         default         UH      0               sl0
Console>

Table 2-43 describes the fields in the show netstat routes command output.


Table 2-43: show netstat routes Command Output Fields
Field Description

DESTINATION

Destination IP address or network.

GATEWAY

Next hop to the destination.

INTERFACE

Interface out of which packets to the destination should be forwarded.

This example shows how to display interface statistics:

Console> show netstat interface
Interface          InPackets InErrors OutPackets OutErrors
sl0                        0        0          0         0
sc0                       33        0     117192         0
me1                        2        0      57075         0
Interface Rcv-Octet            Xmit-Octet
--------- -------------------- --------------------
sc0       2389                 0                   
me1       1172                 0                   
sl0       0                    0                   
Interface Rcv-Unicast          Xmit-Unicast
--------- -------------------- --------------------
sc0       28                   0                   
me1       28                   0                   
sl0       0                    0 
Console> 

Table 2-44 describes the fields in the show netstat interface command output.


Table 2-44: show netstat interface Command Output Fields
Field Description

Interface

Interface number (sl0 is the SLIP interface; sc0 is the in-band interface; me1 is the out-of-band interface).

InPackets

Number of input packets on the interface.

InErrors

Number of input errors on the interface.

OutPackets

Number of output packets on the interface.

OutErrors

Number of output errors on the interface.

Rcv-Octet

Number of octet frames received on the port.

Xmit-Octet

Number of octet frames transmitted on the port.

Rcv-Unicast

Number of unicast frames received on the port.

Xmit-Unicast

Number of unicast frames transmitted on the port.

Related Commands

set interface
set ip route

show ntp

Use the show ntp command to display the current NTP status.

show ntp

Syntax Description

This command has no arguments or keywords.

Defaults

This command has no default setting.

Command Types

Switch command.

Command Modes

Normal.

Examples

This example shows how to display the current NTP status:

Console> show ntp
Current time: Thu Jan 15 1999, 11:19:03 pst
Timezone: 'pst', offset from UTC is -8 hours
Summertime: 'pst', enabled
Last NTP update:
Broadcast client mode: enabled
Broadcast delay: 3000 microseconds
Client mode: disabled
Authentication: enabled
 
NTP-Server                                Server Key
----------------------------------------  ----------
172.20.33.140                             1722033140
172.20.33.114                             1722033114
 
Console>
 

The following output appears in the show ntp command output when entered from privileged mode:

Key Number   Mode        Key String
----------   ---------   --------------------------------
1234         trusted     32423423423
1722033140   untrusted   termserv-am
Console>
 

Table 2-45 describes the fields in the show ntp command output.


Table 2-45: show ntp Command Output Fields
Field Description

Current time

Current system time.

Timezone

Time zone and the offset in hours from UTC.

Summertime

Time zone for daylight saving time and whether the daylight saving time adjustment is enabled or disabled.

Last NTP update

Time of the last NTP update.

Broadcast client mode

Status of whether NTP broadcast-client mode is enabled or disabled.

Broadcast delay

Configured NTP broadcast delay.

Client mode

Status of whether NTP client mode is enabled or disabled.

NTP-Server

List of configured NTP servers.

Related Commands

clear ntp key
clear ntp server
set ntp broadcastclient
set ntp broadcastdelay
set ntp client
set ntp key
set ntp server

show port

Use the show port command to display port status and counters.

show port [mod_num[/port_num]]

Syntax Description

mod_num

(Optional) Number of the module. If you do not specify a number, the ports on all modules are shown.

/port_num

(Optional) Number of the port on the module. If you do not specify a number, all the ports on the module are shown.

Defaults

This command has no default setting.

Command Types

Switch command.

Command Modes

Normal.

Usage Guidelines

In the status field for the Catalyst 5000 family, 4000 family, 2926G series, 2948G, and 2980G switch ports, the following applies:

For Catalyst 4000 family switches, in the show port command display, the combination of the 32-port module (WS-X4502) and 4-port 100FX daughtercard results in an entry that lists 36 ports. If the uplink daughtercard is not installed, only ports 1 through 32 are listed.

Although me1 resides on the supervisor engine module for the Catalyst 4000 family and 2948G switches, me1 port information is not displayed by the show module or show port CLI commands.

The Catalyst 2948G and 2980G switches are fixed configuration switches. Ports are located on module 2 for the 2948G and on modules 2 and 3 for the 2980G; for this reason, if you enter mod_num/port_num 1/N, an error message will be displayed.

Examples

This example shows how to display the status and counters for port 1 on module 3 (Catalyst 5000 family and 2926G series switches):

Console> (enable) show port 3/1
Port  Name               Status     Vlan       Level  Duplex Speed Type
----- ------------------ ---------- ---------- ------ ------ ----- ------------
 3/1                     connected  1          normal   half   100 100BaseFX MM
 
Port  Security Secure-Src-Addr   Last-Src-Addr     Shutdown Trap     IfIndex
----- -------- ----------------- ----------------- -------- -------- -------
 3/1  disabled                                     No       disabled 58     
 
Port     Broadcast-Limit Broadcast-Drop
-------- --------------- --------------
 3/1                   -              0
 
Port  Status     Channel   Channel     Neighbor                  Neighbor
                 mode      status      device                    port
----- ---------- --------- ----------- ------------------------- ---------- 
 3/1  connected  off       not channel
 
Port  Align-Err  FCS-Err    Xmit-Err   Rcv-Err    UnderSize
----- ---------- ---------- ---------- ---------- ---------
 3/1        3384         16          0          0         0
        
Port  Single-Col Multi-Coll Late-Coll  Excess-Col Carri-Sen Runts     Giants
----- ---------- ---------- ---------- ---------- --------- --------- ---------
 3/1           0          0          0          0         0       521         0
        
Last-Time-Cleared
--------------------------
Fri Apr 16 1999, 10:00:46
Console> 
 

This example shows how to display the status and counters for port 2 on a Catalyst 4000 family or 2948G switch:

Console> show port 2
Port  Name               Status     Vlan       Level  Duplex Speed Type
----- ------------------ ---------- ---------- ------ ------ ----- ------------
 2/1                     connected  1          normal   full  1000 1000BaseSX
 2/2                     connected  1          normal   full  1000 1000BaseSX
 2/3                     notconnect 1          normal   full  1000 No GBIC
 2/4                     notconnect 1          normal   full  1000 No GBIC
 2/5                     notconnect 1          normal   full  1000 No GBIC
 2/6                     notconnect 1          normal   full  1000 No GBIC
 
Port  Security Secure-Src-Addr   Last-Src-Addr     Shutdown Trap     IfIndex
----- -------- ----------------- ----------------- -------- -------- -------
 2/1  disabled                                     No       disabled 90     
 2/2  disabled                                     No       disabled 91     
 2/3  disabled                                     No       disabled 92     
 2/4  disabled                                     No       disabled 93     
 2/5  disabled                                     No       disabled 94     
 2/6  disabled                                     No       disabled 95     
        
Port   Send FlowControl    Receive FlowControl   RxPause TxPause Unsupported
       admin    oper       admin    oper                         opcodes
-----  -------- --------   -------- --------     ------- ------- -----------
 2/1   desired  off        off      off          0       0       0
 2/2   desired  off        off      off          0       0       0
 2/3   desired  off        off      off          0       0       0
 2/4   desired  off        off      off          0       0       0
 2/5   desired  off        off      off          0       0       0
 2/6   desired  off        off      off          0       0       0        
        
Port  Align-Err  FCS-Err    Xmit-Err   Rcv-Err    UnderSize
----- ---------- ---------- ---------- ---------- ---------
 2/1           -          0          1          0         0
 2/2           -          8          2          8         0
 2/3           -          0          0          0         0
 2/4           -          0          0          0         0
 2/5           -          0          0          0         0
 2/6           -          0          0          0         0
        
Port  Single-Col Multi-Coll Late-Coll  Excess-Col Carri-Sen Runts     Giants
----- ---------- ---------- ---------- ---------- --------- --------- ---------
 2/1           0          0          0          0         1         0         0
 2/2           0          0          0          0         1         0         0
 2/3           0          0          0          0         0         0         0
 2/4           0          0          0          0         0         0         0
 2/5           0          0          0          0         0         0         0
 2/6           0          0          0          0         0         0         0
        
Last-Time-Cleared
--------------------------
Fri Apr 9 1999, 18:54:17
Console>

Table 2-46 describes the possible fields (depending on the port type queried) in the show port command output.


Table 2-46: show port Command Output Fields
Field Description

Port

Module and port number.

Name

Name (if configured) of the port.

Status

Status of the port. For the Catalyst 5000 family and 2926G series switches, possible displays are connected, notconnect, connecting, standby, faulty, inactive, shutdown, disabled, or monitor; for the Catalyst 4000 family and 2948G switches, possible displays are connected, notconnected, faulty, remfault, disable, remdisable, configerr, remcfgerr, and disagree.

Vlan

VLANs to which the port belongs.

Duplex

Duplex setting for the port (auto, full, fdx, half, hdx, a-half, a-hdx, a-full, or a-fdx).

Speed

Speed setting for the port (auto, 10, 100, 155, a-10, a-100, 4, 16, a-14,or a-16).

Type1

Port type, for example, 100BaseFX MM, 100BaseFX SM, 10/100BaseTX, or RSM.

Security

Status of whether port security is enabled or disabled.

Secure-Src-Addr

Secure MAC address for the security enabled port.

Last-Src-Addr

Source MAC address of the last packet received by the port.

Shutdown

Status of whether the port was shut down because of security.

Trap

Status of whether port trap is enabled or disabled.

IfIndex

Number of the ifIndex.

Broadcast-Limit

Broadcast threshold configured for the port.

Broadcast-Drop

Number of broadcast/multicast packets dropped because the broadcast limit for the port was exceeded.

Send admin

Flow-control administration. Possible settings: on indicates the local port sends flow control to the far end; off indicates the local port does not send flow control to the far end; desired indicates the local end sends flow control to the far end if the far end supports it.

FlowControl oper

Flow-control operation. Possible setting: disagree indicates the two ports could not agree on a link protocol.

Receive admin

Flow-control administration. Possible settings: on indicates the local port requires the far end to send flow control; off indicates the local port does not allow the far end to send flow control; desired indicates the local end allows the far end to send flow control.

FlowControl oper

Flow-control operation. Possible setting: disagree indicates the two ports could not agree on a link protocol.

RxPause

Number of Pause frames received.

TxPause

Number of Pause frames transmitted.

Unsupported Opcodes

Number of unsupported operating codes.

Align-Err

Number of frames with alignment errors (frames that do not end with an even number of octets and have a bad CRC) received on the port.

FCS-Err

The number of valid size frames with FCS errors but no framing errors.

Xmit-Err

Number of transmit errors that occurred on the port (indicating that the internal transmit buffer is full).

Rcv-Err

Number of receive errors that occurred on the port (indicating that the internal receive buffer is full).

UnderSize

Number of received frames less than 64 octets long (but are otherwise well-formed).

Single-Coll

Number of times one collision occurred before the port transmitted a frame to the media successfully.

Multi-Coll

Number of times multiple collisions occurred before the port transmitted a frame to the media successfully.

Late-Coll

Number of late collisions (collisions outside the collision domain).

Excess-Col

Number of excessive collisions that occurred on the port (indicating that a frame encountered 16 collisions and was discarded).

Carri-Sen

Number of times the port sensed a carrier (to determine whether the cable is currently being used).

Runts

Number of received runt frames (frames that are smaller than the minimum IEEE 802.3 frame size) on the port.

Giants

Number of received giant frames (frames that exceed the maximum IEEE 802.3 frame size) on the port.

Last-Time-Cleared

Last time the port counters were cleared.

Auto-Part

The number of times the port entered the auto-partition state due to excessive consecutive collisions.

Data-rate mismatch

The number of valid size frames experienced overrun or underrun.

Src-addr change

The number of times the last source address changed.

Good-bytes

The total number of octets in frames with no error.

Short-event

The number of times activity with a duration less than the ShortEventMax Time (74-82 bit times) is detected.

1These fields will change according to the system configuration.

show port auxiliaryvlan

Use the show port auxiliaryvlan command to display the port auxiliary VLAN status for a specific port.

show port auxiliaryvlan vlan

Syntax Description

vlan

Number of the VLAN; valid values are from 1 to 1000.

Defaults

This command has no default setting.

Command Types

Switch command.

Command Modes

Privileged.

Usage Guidelines

This command is supported by the Catalyst 5000 family switches and the Catalyst 4000 family switches.

This command is not supported by the NAM.

Examples

This example shows how to display the port information for a specific auxiliary VLAN:

Console> (enable) show port auxiliaryvlan 123
AuxiliaryVlan AuxVlanStatus Mod/Ports
------------- ------------- -------------------------
123           active        1/2,2/1-3
Console> (enable)

Table 2-47 describes the possible fields (depending on the port type queried) in the show port auxiliaryvlan command output.


Table 2-47: show port auxiliaryvlan Output
Field Description

AuxiliaryVlan

Number of the auxiliary VLAN.

AuxVlanStatus

Status of the auxiliary VLAN.

Mod/Ports

Number of the module and ports assigned to the auxiliary VLAN.

Related Commands

set port auxiliaryvlan

show port broadcast

Use the show port broadcast command to display broadcast information.

show port broadcast [mod_num[/port_num]]

Syntax Description

mod_num

(Optional) Number of the module.

/port_num

(Optional) Number of the port on the module.

Defaults

This command has no default setting.

Command Types

Switch command.

Command Modes

Normal.

Usage Guidelines

This command is supported by the Catalyst 5000 family switches and the Catalyst 2926G series switches.

On the 1000BaseX switching module, when you specify a port for broadcast suppression, the traffic is suppressed only in the network-to-Catalyst 5000 family and 2926G series switches bus direction.

If you do not specify a mod_num, the ports on all modules are shown.

If you do not specify a /port_num, all the ports on the module are shown.

Examples

This example shows how to display broadcast information for port 2 on module 1:

Console> show port broadcast 1/2
Port     Broadcast-Limit Broadcast-Drop
-------- --------------- --------------
 1/2           75.25%           -
Console> 

Table 2-48 describes the possible fields in the show port broadcast command output.


Table 2-48: show port broadcast Command Output Fields
Field Description

Port

Module and port number.

Broadcast-Limit

Broadcast threshold configured for the port in percent or packets per second.

Broadcast-Drop

Number of broadcast/multicast packets dropped because the broadcast limit for the port was exceeded.

show port capabilities

Use the show port capabilities command to display the capabilities of the modules and ports in a switch.

show port capabilities [mod_num[/port_num]]

Syntax Description

mod_num

(Optional) Number of the module.

/port_num

(Optional) Number of the port on the module.

Defaults

This command has no default setting.

Command Types

Switch command.

Command Modes

Normal.

Usage Guidelines

If you do not specify a mod_num, the ports on all modules are shown.

If you do not specify a /port_num, all the ports on the module are shown.

The Catalyst 2948G and 2980G switches are fixed configuration switches. Ports are located on module 2 for the 2948G and on modules 2 and 3 for the 2980G; for this reason, if you enter mod_num/port_num 1/N, an error message will be displayed.

Examples

This example shows how to show the port capabilities for module 1, port 1:

Console> (enable) show port capabilities 1/1
Model                    WS-X5530
Port                     1/1
Type                     10/100BaseTX
Speed                    auto,10,100
Duplex                   half,full
Trunk encap type         802.1Q,ISL
Trunk mode               on,off,desirable,auto,nonegotiate
Channel                  1/1-2,1/1-4
Broadcast suppression    percentage(0-100)
Flow control             receive-(off,on),send-(off,on)
Security                 yes
Membership               static,dynamic
Fast start               yes
QOS scheduling           rx-(none),tx-(none)
CoS rewrite              yes
ToS rewrite              IP-Precedence
Rewrite                  yes
UDLD                     Capable
Voice vlan               no 

Table 2-49 describes the possible fields (depending on the type of port queried) and the values in the show port capabilities command output.


Table 2-49: show port capabilities Command Output Fields
Field Description

Model

Module model number.

Port

Module number and port number.

Type1

Port type, for example, 100BaseFX MM, 100BaseFX SM, or 10/100BaseTX.

Speed1

Port speed setting (for example, auto, 100, or 1000).

Duplex

Duplex mode (half, full, auto, fdx, hdx, or no).

Trunk encap type

Trunk encapsulation type (ISL, 802.1Q, 802.10, or no).

Trunk mode

Trunk administrative status of the port (on, off, auto, desirable, nonegotiate, or no).

Channel

Status of which ports can form a channel group. The ports are shown in mod_num/port_num format. For example, 3/1-2 indicates module 3, ports 1 and 2. Also, any ports in range [mod/1-mod/high_port] or no ports may be indicated.

Broadcast suppression

Number of packets-per-second (pps) of broadcast/multicast traffic allowed on the port (0-150000) or the percentage of total available bandwidth that can be used by broadcast/multicast traffic (0-100).

Flow control

Flow-control options you can set (receive-[off, on, desired], send-[off, on, desired], or no).

Security

Status of whether port security is enabled (yes, no).

Membership

Method of membership assignment of a port or range of ports to a VLAN (static, dynamic).

Fast Start

Status of whether the spanning-tree port fast-start feature on the port is enabled (yes, no).

QoS Scheduling

(rx-(none),tx-(none)).

CoS Rewrite

Status of whether the port supports COS rewrite (yes, no).

ToS Rewrite

Status of whether the port supports TOS rewrite (IP-Precedence).

Rewrite

Status of whether the port supports inline rewrite (yes, no).

UDLD

Status of whether the port supports UDLD (Capable, Not capable).

Voice Vlan

Status of whether the port supports voice or VLAN (yes, no).

1These fields will change depending on the system configuration.

Related Commands

set port channel
set port broadcast
set port security
set port speed
set spantree portfast
set trunk

show port cdp

Use the show port cdp command to display port CDP enable state and message interval on the port.

show port cdp [mod_num[/port_num]]

Syntax Description

mod_num

(Optional) Number of the module.

/port_num

(Optional) Number of the port on the module.

Defaults

This command has no default setting.

Command Types

Switch command.

Command Modes

Normal.

Usage Guidelines

If you do not specify a mod_num, the ports on all modules are shown.

If you do not specify a /port_num, all the ports on the module are shown.

The Catalyst 2948G and 2980G switches are fixed configuration switches. Ports are located on module 2 for the 2948G and on modules 2 and 3 for the 2980G; for this reason, if you enter mod_num/port_num 1/N, an error message will be displayed.

Examples

This example shows how to display CDP information for all ports:

Console> show port cdp
CDP               :enabled
Message Interval  :60
Hold Time         :180
 
Port      CDP Status 
--------  ---------- 
 2/1      enabled     
 2/2      enabled     
 5/1      enabled     
 5/2      enabled     
 5/3      enabled     
 5/4      enabled     
 5/5      enabled     
 5/6      enabled     
 5/7      enabled     
 5/8      enabled     
Console> 

Table 2-50 describes the fields in the show port cdp command output.


Table 2-50: show port cdp Command Output Fields
Field Description

Port

Module and port number.

CDP Status

CDP status of the port (enabled, disabled).

Message-Interval

Interval between CDP message exchange with neighbor.

Related Commands

set cdp
set cdp interval

show port channel

Use the show port channel command to display EtherChannel information for a specific module or port.

show port channel [mod_num[/port_num]] [statistics | info [spantree | trunk | protocol |
gmrp | gvrp | qos]]

Syntax Description

mod_num

(Optional) Number of the module.

port_num

(Optional) Number of the port.

statistics

(Optional) Keyword that specifies to display EtherChannel PAgP statistics.

info

(Optional) Keyword that specifies to display EtherChannel configuration information.

spantree

(Optional) Keyword that specifies to display only spanning-tree-related configuration information.

trunk

(Optional) Keyword that specifies to display only VLAN-trunk-related configuration information.

protocol

(Optional) Keyword that specifies to display only protocol-filtering-related configuration information.

gmrp

(Optional) Keyword that specifies to display only GMRP-related configuration information.

gvrp

(Optional) Keyword that specifies to display only  GVRP-related configuration information.

qos

(Optional) Keyword that specifies to display only QoS-related configuration information.

Defaults

This command has no default setting.

Command Types

Switch command.

Command Modes

Normal.

Usage Guidelines

If the module and port are not specified, EtherChannel information is shown for all channeling ports on all modules.

Examples

This example shows how to display Fast EtherChannel information for port 1/4:

Console> show port channel 1/4
Port  Status     Channel              Admin Ch
                 Mode                 Group Id
----- ---------- -------------------- ----- -----
 1/1  connected  auto silent             22   769
 1/2  connected  auto silent             22   769
 1/3  connected  auto silent             22   769
 1/4  connected  auto silent             22   769
----- ---------- -------------------- ----- -----
 
Port  Device-ID                       Port-ID                   Platform
----- ------------------------------- ------------------------- ----------------
 1/1  069003103(5500)                 3/13                      WS-C5500
 1/2  069003103(5500)                 3/14                      WS-C5500
 1/3  069003103(5500)                 3/15                      WS-C5500
 1/4  069003103(5500)                 3/16                      WS-C5500
----- ------------------------------- ------------------------- ----------------
Console> 
 

This example shows how to display PAgP packet statistics:

Console> show port channel statistics
Port  Admin   PAgP Pkts   PAgP Pkts PAgP Pkts PAgP Pkts PAgP Pkts PAgP Pkts
      Group   Transmitted Received  InFlush   RetnFlush OutFlush  InError
----- ------- ----------- --------- --------- --------- --------- ---------
 1/1       22        5063      5073         0         0         0         0
 1/2       22        5062      5075         0         0         0         0
 1/3       22        5068      5077         0         0         0         0
 1/4       22        5076      5066         0         0         0         0
----- ------- ----------- --------- --------- --------- --------- ---------
Console> 
 

This example shows how to display EtherChannel configuration information:

Console> show port channel info
Switch Frame Distribution Method: mac both
 
Port  Status     Channel              Admin Channel Speed Duplex Vlan
                 mode                 group id
----- ---------- -------------------- ----- ------- ----- ------ ----
 1/1  connected  auto silent             22     769 a-100 a-full    1
 1/2  connected  auto silent             22     769 a-100 a-full    1
 1/3  connected  auto silent             22     769 a-100 a-full    1
 1/4  connected  auto silent             22     769 a-100 a-full    1
----- ---------- -------------------- ----- ------- ----- ------ ----
 
Port  ifIndex Oper-group Neighbor   Oper-Distribution PortSecurity/
                         Oper-group Method            Dynamic port
----- ------- ---------- ---------- ----------------- -------------
 1/1  626              1            mac both                       
 1/2  626              1            mac both                       
 1/3  626              1            mac both                       
 1/4  626              1            mac both                       
----- ------- ---------- ---------- ----------------- -------------
 
Port  Device-ID                       Port-ID                   Platform
----- ------------------------------- ------------------------- ----------------
 1/1  069003103(5500)                 3/13                      WS-C5500
 1/2  069003103(5500)                 3/14                      WS-C5500
 1/3  069003103(5500)                 3/15                      WS-C5500
 1/4  069003103(5500)                 3/16                      WS-C5500
----- ------------------------------- ------------------------- ----------------
 
Port  Trunk-status Trunk-type    Trunk-vlans
----- ------------ ------------- -----------------------------------------------
 1/1  trunking     n-isl         1-1005
 1/2  trunking     n-isl         1-1005
 1/3  trunking     n-isl         1-1005
 1/4  trunking     n-isl         1-1005
----- ------------ ------------- -----------------------------------------------
 
Port  Portvlancost-vlans
----- --------------------------------------------------------------------------
 1/1  
 1/2  
 1/3  
 1/4  
----- --------------------------------------------------------------------------
 
Port  Port     Portfast Port    Port
      priority          vlanpri vlanpri-vlans
----- -------- -------- ------- ------------------------------------------------
 1/1        32 disabled       0 
 1/2        32 disabled       0 
 1/3        32 disabled       0 
 1/4        32 disabled       0 
----- -------- -------- ------- ------------------------------------------------
 
Port  IP       IPX      Group
----- -------- -------- --------
 1/1  on       auto-on  auto-on 
 1/2  on       auto-on  auto-on 
 1/3  on       auto-on  auto-on 
 1/4  on       auto-on  auto-on 
----- -------- -------- --------
 
Port  GMRP     GMRP         GMRP
      status   registration forwardAll
----- -------- ------------ ----------
 1/1  enabled  normal       disabled  
 1/2  enabled  normal       disabled  
 1/3  enabled  normal       disabled  
 1/4  enabled  normal       disabled  
----- -------- ------------ ----------
        
Port  GVRP     GVRP          GVRP
      status   registeration applicant
----- -------- ------------- ---------
 1/1  disabled normal        normal   
 1/2  disabled normal        normal   
 1/3  disabled normal        normal   
 1/4  disabled normal        normal   
----- -------- ------------- ---------
 
Port  Qos-Tx   Qos-Rx   Qos-Trust    Qos-DefCos
      PortType PortType Type
----- -------- -------- ------------ ----------
 1/1  -        -        untrusted             0
 1/2  -        -        untrusted             0
 1/3  -        -        untrusted             0
 1/4  -        -        untrusted             0
----- -------- -------- ------------ ----------
 
Console>

Table 2-51 describes the fields in the show port channel output.


Table 2-51: show port channel Command Output Fields
Field Description

Port

Module and port number

Status

Port connection status

Channel mode

EtherChannel mode

Admin Group

EtherChannel administrative group

Ch Id

EtherChannel ID

Device-ID

Serial number and hostname of neighboring device

Port-ID

Connected port number on neighboring device

Platform

Neighboring device platform

Table 2-52 describes the fields in the show port channel statistics output.


Table 2-52: show port channel statistics Command Output Fields
Field Description

Port

Port number

Admin Group

EtherChannel administrative group

PAgP Pkts Transmitted

Number of PAgP packets transmitted on the port

PAgP Pkts Received

Number of PAgP packets received on the port

PAgP Pkts InFlush

Number of PAgP flush packets received

PAgP Pkts RetnFlush

Number of PAgP flush packets returned

PAgP Pkts OutFlush

Number of PAgP flush packets transmitted

PAgP Pkts InError

Number of PAgP error packets received

Table 2-53 describes the fields in the show port channel info output.


Table 2-53: show port channel info Command Output Fields
Field Description

Switch Frame Distribution Method

Frame distribution method for all EtherChannels on the switch

Port

Port number

Status

Port connection status

Channel mode

EtherChannel mode

Admin group

EtherChannel administrative group

Channel id

EtherChannel ID

Speed

Port speed

Duplex

Port duplex

Vlan

Port VLAN membership

if-index

Interface index number

Oper-group

Capability of the group

Neighbor Oper-group

Device ID of the neighboring device with which the port is channeling

Chan cost

EtherChannel spanning-tree port cost

Oper-Distribution Method

EtherChannel frame distribution method

PortSecurity/Dynamic Port

Status of whether the port is secure or dynamic

Device-ID

Serial number and hostname of neighboring device

Port-ID

Connected port number on neighboring device

Platform

Neighboring device platform

Trunk-status

VLAN trunking mode

Trunk-type

VLAN trunk encapsulation type

Trunk-vlans

Allowed VLAN list for the trunk

Portvlancost-vlans

Spanning-tree port-VLAN cost and associated VLAN IDs

Port priority

Spanning-tree port priority

Portfast

Spanning-tree PortFast enable state

Port vlanpri-vlans

Spanning-tree port-VLAN priority and associated VLAN IDs

IP

IP protocol filtering mode

IPX

IPX protocol filtering mode

Group

Group protocol filtering mode

GMRP status

GMRP enable state

GMRP registration

GMRP registration mode

GMRP forwardAll

GMRP forward-all enable status

GVRP status

GVRP enable state

GVRP registration

GVRP registration mode

GVRP applicant

GVRP applicant mode

Qos-Tx

Transmit queue and threshold port type

Qos-Rx

Receive queue and threshold port type

Qos-Trust

QoS port trust

QoS-DefCos

QoS default CoS

Related Commands

set channel cost
set channel vlancost
set port channel
show channel
show channel group

show port counters

Use the show port counters command to show all the counters for a port.

show port counters [mod_num/port_num]

Syntax Description

mod_num

(Optional) Number of the module for which to show port counter information.

/port_num

(Optional) Number of the port on the module for which to show port counter information.

Defaults

This command has no default setting.

Command Types

Switch command.

Command Modes

Normal.

Usage Guidelines

If you do not specify a mod_num, the ports on all modules are shown.

If you do not specify a /port_num, all the ports on the module are shown.

The Catalyst 2948G and 2980G switches are fixed configuration switches. Ports are located on module 2 for the 2948G and on modules 2 and 3 for the 2980G; for this reason, if you enter mod_num/port_num 1/N, an error message will be displayed.

Examples

This example shows the output of the show port counters command:

Console> (enable) show port counters
Port Align-Err  				FCS-Err    Xmit-Err   Rcv-Err    Broad-Limit Broad-Drop 
---- ---------- ---------- ---------- ---------- ----------- ---------- 
1/1    0         0          0           0          -            0 
1/2    0         0          0           0          -            0 
4/1	    0         0          0           0          10000p/s     0 
4/2    0         0          0           0          100p/s       53728 
4/3    0         0          0           0          -            0
4/4    0         0          0           0          11.50p/s      52 
Port Single-Col Multi-Coll Late-Coll  Excess-Col Carri-Sens Runts Giants 
---- ---------- ---------- --------- ---------- ---------- ----- ------
1/1    0           0           0        0          0         0      -
1/2    0           0           0        0          0         0      -
4/1    0           0           0        0          0         0      -
4/2    0           0           0        0          0         0      -
4/3    0           0           0        0          0         0      -
4/4	    0           0           0        0          0         0      -
 
                                    Ler
Port  CE-State Conn-State Type Neig Con Est Alm Cut Lem-Ct     Lem-Rej-Ct Tl-Min
----- -------- ---------- ---- ---- --------------- ---------- ---------- ------
 3/1  isolated connecting A    U    no    9   9   7          0          0 102
 3/2  isolated connecting B    U    no    9   8   7          0          0 40
 
Last-Time-Cleared
-------------------------- 
Wed Apr 10 1996, 14:59:51 
Console> (enable) 

Table 2-54 describes the possible fields (depending on the port type queried) in the show port counters command output.


Table 2-54: show port counters Command Output Fields
Field Description

Port

Module and port number.

Align-Err

Number of frames with alignment errors (frames that do not end with an even number of octets and have a bad CRC) received on the port.

FCS-Err

Number of frame check sequence errors that occurred on the port.

Xmit-Err

Number of transmit errors that occurred on the port (indicating that the internal transmit buffer is full).

Rcv-Err

Number of receive errors that occurred on the port (indicating that the internal receive buffer is full).

UnderSize

Number of received frames less than 64 octets long (but are otherwise well formed).

Broadcast-Limit

Broadcast threshold configured for the port in percent or packets per second.

Broadcast-Drop

Number of broadcast/multicast packets dropped because the broadcast limit for the port was exceeded.

Single-Coll

Number of times one collision occurred before the port successfully transmitted a frame to the media.

Multi-Coll

Number of times multiple collisions occurred before the port successfully transmitted a frame to the media.

Late-Coll

Number of late collisions (collisions outside the collision domain).

Excess-Col

Number of excessive collisions that occurred on the port (indicating that a frame encountered 16 collisions and was discarded).

Carri-Sen

Number of times the port sensed a carrier (to determine whether the cable is currently being used).

Runts

Number of received runt frames (frames that are smaller than the minimum IEEE 802.3 frame size) on the port.

Giants

Number of received giant frames (frames that exceed the maximum IEEE 802.3 frame size) on the port.

CE-State

Connection entity status.

Conn-State

Connection state of the port, as follows:

  • Disabled---The port has no line module or was disabled by the user.

  • Connecting---The port attempted to connect or was disabled.

  • Standby---The connection was withheld or was the inactive port of a dual-homing concentrator.

  • Active---The port made a connection.

  • Other---The concentrator was unable to determine the Conn-State.

Type

Type of port, such as A---A port and B---B port.

Neig

Type of port attached to this port. The neighbor can be one of these types:

  • A---A port

  • B---B port

  • M---M port

  • S---Slave port

  • U---The concentrator cannot determine the type of the neighbor port.

Ler Con

Status of whether the port is currently in a LER condition.

Est

Estimated LER.

Alm

LER at which a link connection exceeds the LER alarm threshold.

Cut

LER cutoff value (the LER at which a link connection is flagged as faulty).

Lem-Ct

Number of LEM errors received on the port.

Lem-Rej-Ct

Number of times a connection was rejected because of excessive LEM errors.

Tl-Min

TL-min value (the minimum time to transmit a FDDI PHY line state) before advancing to the next PCM state.

Last-Time-Cleared

Last time the port counters were cleared.

Related Commands

show port

show port filter

Use the show port filter command to view MAC addresses and protocol filters that have been configured on the Token Ring module ports.

show port filter [mod_num] [canonical]

show port filter mod_num/port_num [canonical]

show port filter mac_addr [canonical]

Syntax Description

mod_num

(Optional) Number of the module.

canonical

(Optional) Keyword that specifies the MAC address display in canonical format.

/port_num

Number of the port on the module.

mac_addr

MAC address contained in the packets to be filtered. You need to enter this address in canonical format (00-11-33-44-55) or in noncanonical format (00:11:22:33:44:55).

Defaults

By default, MAC addresses are shown in noncanonical format.

Command Types

Switch command.

Command Modes

Normal.

Usage Guidelines

This command is supported by the Catalyst 5000 family switches.

Examples

This example shows how to display the filters configured for a port on the Token Ring module:

Console> show port filter 3/1
Port  Mac-Addr          Type
----- ----------------- ------
 3/1  00:00:00:00:00:00 deny
      00:00:00:00:00:00 deny
      00:00:00:00:00:00 deny
      00:00:00:00:00:00 deny
 
Port  Protocol          Type
----- ----------------- ------
 3/1  0x8038            deny
      0xf0f0            deny

Table 2-55 describes the fields in the show port filter command output.


Table 2-55: show port filter Command Output Fields
Field Description

Port

Module and port number.

MAC-Addr

MAC address contained in packets to be filtered.

Type

Type of MAC address filter configured. Possible types are deny (block any packet containing a specific MAC address) or permit (allow any packet containing a specific MAC address).

Protocol

Types of protocols that you want to filter.

Type

Type of protocol filter configured. Possible types are deny (block any packet containing a specific protocol type) or permit (allow any packet containing a specific protocol type).

Related Commands

clear port filter
set port filter

show port flowcontrol

Use the show port flowcontrol command to display per-port status information and statistics related to flow control.

show port flowcontrol [mod_num[/port_num]]

Syntax Description

mod_num

(Optional) Number of the module.

/port_num

(Optional) Number of the port on the module. If you do not specify a number, filters configured on all the ports on the module are shown.

Defaults

This command has no default setting.

Command Types

Switch command.

Command Modes

Normal.

Usage Guidelines

The Catalyst 2948G and 2980G switches are fixed configuration switches. Ports are located on module 2 for the 2948G and on modules 2 and 3 for the 2980G; for this reason, if you enter mod_num/port_num 1/N, an error message will be displayed.

Examples

This example shows how to display the flow-control port status and statistics:

Console> show port flowcontrol
Port   Send-Flowcontrol   Receive-Flowcntl   RxPause   TxPause
       Admin   Oper       Admin   Oper
-----  ----------------   ----------------   -------   ------
 3/1   on      disagree   on      disagree   0         0
 3/2	   off     off        off     off        0         0
 3/3   desired on         desired off        10        10
Console> 

Table 2-56 describes the fields in the show port flowcontrol command output.


Table 2-56: show port flowcontrol Command Output Fields
Field Description

Port

Module and port number.

Send-Flowcontrol-
Admin

Flow-control administration. Possible settings: on indicates the local port sends flow control to the far end; off indicates the local port does not send flow control to the far end; desired indicates the local end sends flow control to the far end if the far end supports it.

Send-Flowcontrol-
Oper

Flow-control operation. Possible setting: disagree indicates the two ports could not agree on a link protocol.

Receive-Flowcntl-
Admin

Flow-control administration. Possible settings: on indicates the local port requires the far end to send flow control; off indicates the local port does not allow the far end to send flow control; desired indicates the local end allows the far end to send flow control.

Receive-Flowcntl-
Oper

Flow-control operation. Possible setting: disagree indicates the two ports could not agree on a link protocol.

RxPause

Number of Pause frames received.

TxPause

Number of Pause frames transmitted.

Related Commands

set port flowcontrol

show port ifindex

Use the show port ifindex command to view ifIndex information on a per-port or per-module basis.

show port ifindex [mod_num]

show port ifindex mod_num/port_num

Syntax Description

mod_num

(Optional) Number of the module.

port_num

Number of the port.

Defaults

This command has no default settings.

Command Types

Switch command.

Command Modes

Normal.

Usage Guidelines

The Catalyst 2948G and 2980G switches are fixed configuration switches. Ports are located on module 2 for the 2948G and on modules 2 and 3 for the 2980G; for this reason, if you enter mod_num/port_num 1/N, an error message will be displayed.

Examples

This example shows how to display ifIndex information for all the ports:

Console> show port ifindex
Port   ifIndex
-----  -------
 1/1   3
 1/2   4
 3/1   383
 3/2   384
 4/1   385
 4/2   386
 4/3   387
 4/4   388
 4/5   389
 4/6   390
 4/7   391
 4/8   392
 4/9   393
 4/10  394
 4/11  395
 4/12  396
 4/13  397
Console> 

show port negotiation

Use the show port negotiation command to display the link negotiation protocol setting for the specified port.

show port negotiation [mod_num[/port_num]]

Syntax Description

mod_num

(Optional) Number of the module.

/port_num

(Optional) Number of the port on the module.

Defaults

This command has no default setting.

Command Types

Switch command.

Command Modes

Normal.

Usage Guidelines

The Catalyst 2948G and 2980G switches are fixed configuration switches. Ports are located on module 2 for the 2948G and on modules 2 and 3 for the 2980G; for this reason, if you enter mod_num/port_num 1/N, an error message will be displayed.

This command is supported on Gigabit Ethernet and some Fast Ethernet ports. If the port does not support the command, the following message appears (where N/N is the module and port number):

Feature not supported on Port N/N.

Examples

This example shows how to display the link negotiation protocol settings on module 3, port 1:

Console> show port negotiation 3/1
Port     Link Negotiation
------- --------------------
3/1          enabled
Console> 

Related Commands

show port flowcontrol
set port negotiation

show port protocol

Use the show port protocol command to view protocol filters configured on the ports.

show port protocol [mod_num[/port_num]]

Syntax Description

mod_num

(Optional) Number of the module.

/port_num

(Optional) Number of the port on the module.

Defaults

This command has no default setting.

Command Types

Switch command.

Command Modes

Normal.

Usage Guidelines

If you do not specify a /port_num, filters configured on all the ports on the module are shown.

The Catalyst 2948G and 2980G switches are fixed configuration switches. Ports are located on module 2 for the 2948G and on modules 2 and 3 for the 2980G; for this reason, if you enter mod_num/port_num 1/N, an error message will be displayed.

Examples

This example shows how to view protocol filters on configured ports:

Console> show port protocol
Port     Vlan       IP       IP Hosts IPX      IPX Hosts Group    Group Hosts
-------- ---------- -------- -------- -------- --------- -------- -----------
1/1      1          on       0        on       0         on       0
1/2      1          on       0        on       0         on       0
2/1      1          on       3        auto-on  0         auto-on  0
2/2      1          on       0        on       0         on       0
2/3      1          on       0        on       0         on       0
2/4      1          on       0        on       0         on       0
2/5      1          on       0        on       0         on       0
2/6      1          on       0        on       0         on       0
2/7      1          on       0        on       0         on       0
2/8      1          on       0        on       0         on       0
2/9      1          on       0        on       0         on       0
2/10     1          on       0        on       0         on       0
Console> 
 

This example shows how to view protocol filters on port 15 of module 3:

Console> (enable) show port protocol 3/15
Port     Vlan       IP       IP Hosts IPX      IPX Hosts Group    Group
Hosts
-------- ---------- ------- -------- -----      -------- -----   -------- 
3/15     1000       auto-on 2        auto-off  0         auto-off  0      
 
To:
 
Port     Vlan       AuxVlan IP       IP    IPX      IPX   Group    Group
                            Status   Hosts Status   Hosts Status   Hosts
-------- ---------- ------- -------- ----- -------- ----- -------- ----- 
 3/15    1000       234     auto-on  2     auto-off 0     auto-off  0 
Console> (enable)

Related Commands

set port protocol

show port qos

Use the show port qos command to display QoS-related information.

show port qos [mod[/port]]

Syntax Description

mod[/port]

(Optional) Number of the module and port.

Defaults

This command has no default setting.

Command Types

Switch command.

Command Modes

Normal.

Usage Guidelines


Note When a switchover occurs, you cannot view the ACLs and policers deployed using COPS-DS until the COPS-DS client on the new active supervisor engine establishes connection to the PDP and downloads the QoS policy. The runtime fields in the output display will be blank until QoS policy is downloaded to the new active supervisor engine.

This command is supported only on Catalyst 5000 family switches with Supervisor Engine II G or III G, or Supervisor Engine III or III F with the NFFC II.

Examples

This example shows how to display QoS-related information for a specific module and port:

Console> show port qos 2/1
QoS is enabled for the switch.
QoS policy source for the switch set to local.
 
Port  Interface Type Interface Type Policy Source Policy Source
      config         runtime        config        runtime
----- -------------- -------------- ------------- -------------
2/1      vlan-based     vlan-based          COPS         local
 
Port  TxPort Type  RxPort Type  Trust Type   Trust Type   Def CoS Def CoS
                                config       runtime      config  runtime
----- ------------ ------------ ------------ ------------ ------- -------
2/1          2q2t         1q4t    untrusted    untrusted       0
 
Config:
Port  ACL name                         Type
----- -------------------------------- ----
No ACL is mapped to port 2/1.
 
 
 
Runtime:
Port  ACL name                         Type
----- -------------------------------- ----
No ACL is mapped to port 2/1.
Console> 
 

This example shows how to display QoS-related information for a single port on a specific module, which, in this example, is connected to a port on a phone device:

Console> (enable) show port qos 3/4  
QoS is disabled for the switch.
Configured settings are not used.
QoS policy source for the switch set to local.
 
Port  Interface Type Interface Type Policy Source Policy Source
      config         runtime        config        runtime
----- -------------- -------------- ------------- -------------
 3/4               -              -         local         local
 
Port  TxPort Type  RxPort Type  Trust Type   Trust Type    Def CoS Def CoS
                                config       runtime       config  runtime
----- ------------ ------------ ------------ ------------- ------- -------
 3/4          2q2t         1q4t    untrusted    trust-cos        0       0 
Port  Ext-Trust Ext-Cos 
----- --------- -------
 3/4  untrusted       0
 
(*)Trust type set to untrusted.
 
Config:
Port  ACL name                         Type
----- -------------------------------- ----
No ACL is mapped to port 3/4.
 
Runtime:
Port  ACL name                         Type
----- -------------------------------- ----
No ACL is mapped to port 3/4.
Console> (enable) 

Related Commands

set qos
set qos ip-filter
set qos mac-cos
set qos map
set port qos
set port qos cos
set port qos trust
set qos router-mac
set qos wred-threshold

show port security

Use the show port security command to view port security configuration information and statistics.

show port security mod/ports... [statistics]

Syntax Description

mod

Number of the module.

ports...

Number of the ports.

statistics

Keyword that specifies to display security statistics.

Defaults

By default configuration information is displayed.

Command Types

Switch command.

Command Modes

Privileged.

Usage Guidelines

If you issue this command against a Token Ring port, the following message is generated:

Feature not supported for Module x.
 

This command is not supported by the three-port Gigabit Ethernet switching module (WS-X5403).

The Catalyst 2948G and 2980G switches are fixed configuration switches. Ports are located on module 2 for the 2948G and on modules 2 and 3 for the 2980G; for this reason, if you enter mod_num/port_num 1/N, an error message will be displayed.

Examples

This example shows how to display port security configuration information on a secured port and the output:

Console> (enable) show port security 4/1
Port  Security Violation Shutdown-Time Age-Time Maximum-Addrs Trap     IfIndex
----- -------- --------- ------------- -------- ------------- -------- -------
 4/1  enabled  shutdown  120           1440     25            disabled 3
 
 
Port Secure-Src-Addrs  Age-Left Last-Src-Addr     Shutdown Shutdown-Time-Left
---- ----------------- -------- ----------------- -------- ------------------
 4/1 00-11-22-33-44-55 4        00-11-22-33-44-55 No       -
     00-10-14-da-77-f1 100                                  
 

This example shows the output on a port that has experienced a security violation:

Console> (enable) show port security 4/1
Port  Security Violation Shutdown-Time Age-Time Maximum-Addrs Trap     IfIndex
----- -------- --------- ------------- -------- ------------- -------- -------
 4/1  enabled  shutdown  120           600      25            disabled 3
 
Port Secure-Src-Addrs  Age-Left Last-Src-Addr     Shutdown Shutdown-Time-Left
---- ----------------- -------- ----------------- -------- ------------------
 4/1 00-11-22-33-44-55 60       00-11-22-33-44-77 Yes      -
     00-10-14-da-77-f1 200
     00-11-22-33-44-66 200
 

This example shows that port 4/1 has been shut down and that the timeout left is 60 minutes before the port will be reenabled:

Console> (enable) show port security 4/1
Port  Security Violation Shutdown-Time Age-Time Maximum-Addrs Trap     IfIndex
----- -------- --------- ------------- -------- ------------- -------- -------
 4/1  enabled  restrict  120           600      25            disabled 3
 
Port Secure-Src-Addrs  Age-Left Last-Src-Addr     Shutdown Shutdown-Time-Left
---- ----------------- -------- ----------------- -------- ------------------
 4/1 00-11-22-33-44-55 60       00-11-22-33-44-77 Yes      -
     00-10-14-da-77-ff

Related Commands

set port security
clear port security

show port security statistics

Use the show port security command to view port security configuration statistics.

show port security statistics mod | mod/port [system]

Syntax Description

mod

Number of the module.

mod/port

Number of the module and port.

system

(Optional) Keyword that specifies to display systemwide configuration statistics.

Command Types

Switch command.

Command Modes

Privileged.

Usage Guidelines

If you issue this command against a Token Ring port, the following message is generated:

Feature not supported for Module x.
 

This command is not supported by the three-port Gigabit Ethernet switching module (WS-X5403).

The Catalyst 2948G and 2980G switches are fixed configuration switches. Ports are located on module 2 for the 2948G and on modules 2 and 3 for the 2980G; for this reason, if you enter mod_num/port_num 1/N, an error message will be displayed.

Examples

This example shows how to display port security configuration information on a secured port and the output:

Console> (enable) show port security statistics system
Module 1:
  Total ports: 4
  Total MAC address(es): 4
  Total global address space used (out of 1024): 0
  Status: installed
 
Module 3:
  Total ports: 24
  Total MAC address(es): 24
  Total global address space used (out of 1024): 0
  Status: installed
Module 8:
  Module does not support port security feature
Module 10:
  Module does not support port security feature
Console> (enable) 

Related Commands

set port security
clear port security

show port status

Use the show port status command to display port status information.

show port status [mod_num[/port_num]]

Syntax Description

mod_num

(Optional) Number of the module.

/port_num

(Optional) Number of the port on the module.

Defaults

This command has no default setting.

Command Types

Switch command.

Command Modes

Normal.

Usage Guidelines

The Catalyst 2948G and 2980G switches are fixed configuration switches. Ports are located on module 2 for the 2948G and on modules 2 and 3 for the 2980G; for this reason, if you enter mod_num/port_num 1/N, an error message will be displayed.

If you do not specify a mod_num, the ports on all modules are shown.

If you do not specify a /port_num, all the ports on the module are shown.

Examples

This example shows how to display port status information for all ports:

Console> show port status
Port  Name               Status     Vlan       Level  Duplex Speed Type
----- ------------------ ---------- ---------- ------ ------ ----- ------------
 1/1                     connected  523        normal   half   100 100BaseTX
 1/2                     notconnect 1          normal   half   100 100BaseTX
 2/1                     connected  trunk      normal   half   400 Route Switch
 3/1                     notconnect trunk      normal   full   155 OC3 MMF ATM
 5/1                     notconnect 1          normal   half   100 FDDI
 5/2                     notconnect 1          normal   half   100 FDDI
Console> 

Table 2-57 describes the fields in the show port status command output.


Table 2-57: show port status Command Output Fields
Field Description

Port

Module and port number.

Name

Name (if configured) of the port.

Status

Status of the port (connected, notconnect, connecting, standby, faulty, inactive, shutdown, disabled, or monitor).

Vlan

VLANs to which the port belongs.

Level

Level setting for the port (normal or high).

Duplex

Duplex setting for the port (auto, full, fdx, half, hdx, a-half, a-hdx, a-full, or a-fdx).

Speed

Speed setting for the port (auto, 10, 100,155, a-10, a-100, 4, 16, a-14,or a-16).

Type1

Port type, for example, 10BaseT, 10BaseFL MM, 100BaseTX, 100BaseT4, 100BaseFX MM, 100BaseFX SM, 10/100BaseTX, TokenRing, FDDI, CDDI, or RSM.

1These fields will change according to the system configuration.

show proc

Use the show proc command to display CPU, memory allocation, and process utilization information.

show proc [cpu | mem] {mod_num}

Syntax Description

cpu

(Optional) Keyword that specifies CPU information.

mem

(Optional) Keyword that specifies malloced memory information.

mod_num

Number of the module.

Defaults

This command has no default setting.

Command Types

Switch command.

Command Modes

Privileged.

Usage Guidelines

This command can only be entered in privileged mode. If you do not specify cpu or mem, process information is displayed.

The mem keyword allows you to display malloced memory information, such as how much each process has allocated and how much memory it has freed can be obtained.

Examples

This example shows how to display CPU information:

Console> (enable) show proc cpu
 
CPU utilization for five seconds:   1.44%
                      one minute:   1.96%
                    five minutes:   1.02%
 
PID Runtime(ms) Invoked    uSecs    5Sec    1Min    5Min    TTY Process
--- ----------- ---------- -------- ------- ------- ------- --- ---------------
1   0           0          0         98.56%  98.04%  98.98% 0   Kernel and Idle
2   4           38         1000       0.00%   0.00%   0.00% 0   Flash MIB Updat
3   1421        5547       466000     0.00%   0.00%   0.00% 0   SynDiags       
4   166212      519822     19000      0.22%   0.00%   0.00% 0   SynConfig      
5   185         94681      1000       0.00%   0.00%   0.00% 0   Statuspoll     
6   472         297        0          0.00%   0.00%   0.00% 0   SWPoll64bCnt   
7   90          3548211    1000       0.00%   0.00%   0.00% 0   SL_TASK        
8   113         141960     106000     0.00%   0.00%   0.00% 0   RedundantTask 
Console> (enable) 
 

This example shows how to display process information:

Console> (enable) show proc mem
 
Memory Used:   1281040
      Freed:   9597104
      Total:  10878144
 
PID        TTY        Allocated  Freed      Holding    Process
---------- ---------- ---------- ---------- ---------- ---------------
1          0          711008     2832       708176     Kernel and Idle
2          0          240        0          240        Flash MIB Updat
3          0          284128     283712     416        SynDiags       
4          0          211856     1920       209936     SynConfig      
5          0          96         0          96         Statuspoll     
6          0          4944       4352       592        SWPoll64bCnt   
7          0          80         0          80         SL_TASK        
8          0          2272       1952       320        RedundantTask
Console> (enable) 
 

This example shows how to display process utilization information:

Console> (enable) show proc
 
CPU utilization for five seconds:   0.44%
                      one minute:   1.00%
                    five minutes:   1.00%
 
PID Q  T  PC         Runtime(ms) Invoked  uSecs   Stacks    TTY Process
--- -- -- ---------- ----------- -------- ------- --------- --- ---------------
1   1  rd 0x8041ab80 0           0        0       1580/6144 0   Kernel and Idle
2   1  st 0x8041adfc 4           38       1000    1604/6144 0   Flash MIB Updat
3   2  st 0x8041adfc 1421        5547     466000  3364/6144 0   SynDiags       
4   1  si 0x8041adfc 166438      520543   19000   1764/6144 0   SynConfig      
5   2  si 0x8041adfc 186         94812    1000    1576/6144 0   Statuspoll     
6   4  si 0x8041adfc 472         297      0        244/6144 0   SWPoll64bCnt   
7   2  si 0x8041adfc 92          3553068  1000     904/6144 0   SL_TASK        
8   2  si 0x8041adfc 113         142157   106000  1172/6144 0   RedundantTask
Console> (enable) 
 

Table 2-58 describes the possible fields in the show proc command outputs.


Table 2-58: show proc Command Output Fields
Field Definition

CPU Utilization

Sum of all the loads from all the processes running on the CPU in the last 5 seconds, 1 minute, and 5 minutes.

PID

Process ID.

Runtime

Time the process has run since getting created (in milliseconds).

Invoked

Number of times the process was invoked since getting created.

uSecs

Maximum time a process ran in a single invocation.

5sec

Percentage of time this process ran on the CPU in the last 5 second interval.

1Min

Percentage of time this process ran on the CPU in the last 1 minute interval.

5Min

Percentage of time this process ran on the CPU in the last 5 minute interval.

TTY

TTY associated with the process.

Process

Name of the process.

Allocated

Sum of all the memory malloced by the process since it was created, and includes the memory previously freed.

Freed

Sum of memory the process has freed until now.

Holding

Amount of memory the process is currently holding.

PC

Calling PC for "show_process" function.

Q

Process priority in terms of numbers. Low number means high priority.

T

State of the process (Running, we=waiting for event, st=sleeping, si=sleeping on an interval, rd=ready to run, id=idle, xx=dead/zombie).

Stacks

Size of the stack used by the process or the total stack size allocated to the process (in bytes).

show protocolfilter

Use the show protocolfilter command to list whether protocol filtering is enabled or disabled.

show protocolfilter

Syntax Description

This command has no keywords or arguments.

Defaults

This command has no default setting.

Command Types

Switch command.

Command Modes

Normal.

Usage Guidelines

This command is not supported by the three-port Gigabit Ethernet switching module (WS-X5403).

Examples

This example shows how to display whether protocol filtering is enabled or disabled:

Console> show protocolfilter
Protocol filtering is enabled on this switch.
Console> 

Related Commands

set port protocol

show qos info

Use the show qos info command to display QoS-related information for a specified port.

show qos info {runtime | config}

show qos info {runtime | config} mod_num/port_num

show qos info config port_type tx

Syntax Description

runtime

Keyword that specifies to show the current QoS run time information.

config

Keyword that specifies to show the NVRAM setting of QoS.

mod_num /port_num

Number of the module and the port.

port_type

QoS port type. Valid port type is 1q4t.

tx

Keyword that specifies to specify the transmit drop threshold.

Defaults

This command has no default setting.

Command Types

Switch command.

Command Modes

Normal.

Usage Guidelines

This command is supported by the Catalyst 5000 family switches, Catalyst 4000 family switches, and the Catalyst 2948G and 2980G switch.

On the Catalyst 5000 family switches, this command is supported only with Supervisor Engine II G or III G, or Supervisor Engine III or III F with the NFFC II.

The mod_num /port_num argument, the port_type argument, and the tx keyword are not supported on the Catalyst 4000 family and 2948G switches.

The show qos info runtime command display shows both the absolute values and the percentages you specified for the drop thresholds, queue sizes, and WRR. However, the absolute values may not exactly match the percentages specified because of the precision limitations of the hardware.

On the Catalyst 5000 family switches, the transmit drop threshold percentages specified select a buffer usage level where each threshold applies. The percentages to buffer usage level shown below are approximate values that depend on the packet buffer size, which depends on the ASIC type.

The number preceding the t in the port-type determines the number of threshold values that the hardware supports. For example, with 1q4t, four thresholds are specified. The number preceding the q in the port-type determines the number of the queues that the hardware supports. For example, with 1q4t, one queue is specified.

Examples

This example shows how to display QoS-related NVRAM transmit threshold information (Catalyst 5000 family switches):

Console> (enable) show qos info config 1q4t tx
QoS setting in NVRAM for 1q4t transmit:
QoS is enabled
Queue and Threshold Mapping:
Queue Threshold CoS            
----- --------- ---------------
1     1         0 1 
1     2         2 3 
1     3         4 5 
1     4         6 7 
Tx WRED thresholds:
Queue #  Thresholds in percentage ( in abs values )
-------  ------------------------------------------
1        14% 28% 57% 100% 
Console> 
 

This example shows how to display the current QoS runtime information for a port (Catalyst 5000 family switches):

Console> show qos info runtime 8/1
Run time setting of QoS:
QoS is enabled
Port 8/1 has 1 transmit queue with 4 drop thresholds (1q4t).
Default CoS = 0    
Queue and Threshold Mapping:
Queue Threshold CoS            
----- --------- ---------------
1     1         0 1 
1     2         2 3 
1     3         4 5 
1     4         6 7 
Tx WRED thresholds:
Queue #  Thresholds in percentage ( in abs values )
-------  ------------------------------------------
1        14% (16380 bytes) 28% (32764 bytes) 57% (65532 bytes) 100% (131068 bytes) 
Console> 

This example shows how to display the current QoS configuration information for the switch (Catalyst 4000 family and 2948G switches):

Console> show qos info config
QoS setting in NVRAM:
QoS is enabled
All ports have 2 transmit queues with 1 drop thresholds (2q1t).
Default CoS = 4    
Queue and Threshold Mapping:
Queue Threshold CoS            
----- --------- ---------------
1     1         0 1 2 3 
2     1         4 5 6 7 
Console>

Related Commands

set qos
set qos ip-filter
set qos mac-cos
set qos map
set qos router-mac
set qos wred-threshold

show qos ip

Use the show qos ip command to display the access control list.

show qos ip [runtime]

Syntax Description

runtime

(Optional) Keyword that displays the runtime configuration verses the user configured configuration.

Defaults

This command has no default setting.

Command Types

Switch command.

Command Modes

Normal.

Usage Guidelines

This command is supported only on Catalyst 5000 family switches with Supervisor Engine II G or III G, or Supervisor Engine III or III F with the NFFC II.

The runtime and user configured settings are different only if the QoS runtime policy source for the switch is COPS.

Examples

This example shows how to display the access control list and its details when COPS is disabled:

Console> (enable) show qos ip runtime 
There are 1 IP filter(s).
ACE# Src IP and Mask                  Dest IP and Mask
---- -------------------------------- --------------------------------
   1 171.33.22.7 0.0.0.255            172.22.33.5 0.0.255.255         
     Protocol Src Port Dst Port CoS Action
     -------- -------- -------- --- ------
     any      0        0        3   -
Console> (enable)
 

This example shows how to display the access control list and its details when COPS is enabled:

Console> (enable) show qos ip runtime
ACL# ACE# Src IP and Mask                  Dest IP and Mask
---- ---- -------------------------------- --------------------------------
   1    1 1.2.3.4 0.0.255.255              host 5.6.7.8                    
            Protocol Src Port Range Dst Port Range CoS Action
            -------- -------------- -------------- --- ------
            any      0 - 65535      0 - 65535      4   permit
 
   1    2   any                              any
            Protocol Src Port Range Dst Port Range CoS Action
            -------- -------------- -------------- --- ------
            any      0 - 65535      0 - 65535      4   deny
 
ACL# ACE# Src IP and Mask                  Dest IP and Mask
---- ---- -------------------------------- --------------------------------
   2    1 1.2.3.4 0.0.255.255              host 5.6.7.8
            Protocol Src Port Range Dst Port Range CoS Action
            -------- -------------- -------------- --- ------
            any      0 - 65535      0 - 65535      0   permit
Console> (enable)

Related Commands

set qos ip-filter
clear qos ip-filter

show qos mac-cos

Use the show qos mac-cos command to display the currently configured QoS-related information for the MAC address and VLAN pair.

show qos mac-cos dest_mac [vlan]

show qos mac-cos all

Syntax Description

dest_mac

MAC address of the destination host.

vlan

(Optional) Number of the VLAN; valid values are 1 to 1005.

all

Keyword that specifies all MAC address and VLAN pairs.

Defaults

This command has no default setting.

Command Types

Switch command.

Command Modes

Normal.

Usage Guidelines

This command is supported only on Catalyst 5000 family switches with Supervisor Engine II G or III G, or Supervisor Engine III or III F with the NFFC II.

You can enter the show qos mac-cos command to display the currently configured QoS-related information. You can enter the show qos info config to view the NVRAM setting of QoS. This command might be useful to check if the NVRAM setting is different from the hardware setting. For example, if you configure some settings for QoS while QoS is disabled, the setting is saved in NVRAM but the hardware is operating with a different set of parameters.

Examples

This example shows how to display currently configured QoS-related information for all MAC address and VLAN pairs:

Console> (enable) show qos mac-cos all
VLAN  Dest MAC            CoS
----  ------------------  ---
1      01-02-03-04-05-06  2
9      04-05-06-07-08-09  3
Console> (enable) 
 

This example shows how to display currently configured QoS-related information for a specific MAC address:

Console> (enable) show qos mac-cos 01-02-03-04-05-06
VLAN  Dest MAC            CoS
----  ------------------  ---
1      01-02-03-04-05-06  2
Console> (enable) 

Related Commands

set qos mac-cos
clear qos mac-cos

show qos policy-source

Use the show qos policy-source command to display the QoS policy source information.

show qos policy-source

Syntax Description

This command has no arguments or keywords.

Defaults

This command has no default settings.

Command Types

Switch command.

Command Modes

Normal.

Usage Guidelines

This command is supported only on Catalyst 5000 family switches with Supervisor Engine II G or III G, or Supervisor Engine III or III F with the NFFC II.

This command displays whether the QoS policy source is set to local or COPS.

Examples

This example shows how to view the QoS policy source:

Console> show qos policy-source
QoS policy source for the switch set to local.
QoS runtime policy source for the switch is local.
Console>

Related Commands

set qos policy-source

show qos router-mac

Use the show qos router-mac command to display QoS router information for the MAC address and VLAN pair.

show qos router-mac [mac_addr | vlan]

Syntax Description

mac_addr

(Optional) MAC address of the router.

vlan

(Optional) Number of the VLAN; valid values are 1 to 1005.

Defaults

This command has no default setting.

Command Types

Switch command.

Command Modes

Normal.

Usage Guidelines

This command is supported only on Catalyst 5000 family switches with Supervisor Engine II G or III G, or Supervisor Engine III or III F with the NFFC II.

The Number column displays a number indicating the order in which the entries were configured. This number has no functional significance to the entry.

Examples

This example shows how to display QoS router information for all MAC address and VLAN pairs:

Console> (enable) show qos router-mac
Number  MAC address        Vlan #
---------------------------------
     1  00-40-0b-30-03-48  2
     2  00-40-0b-30-03-48  3
Console> (enable) 
 

This example shows how to display QoS router information for a specific MAC address:

Console> (enable) show qos router-mac 00-40-0b-30-03-48
Number  MAC address        Vlan #
---------------------------------
     1  00-40-0b-30-03-48  2
     2  00-40-0b-30-03-48  3
Console> (enable) 

Related Commands

set qos router-mac
clear qos router-mac

show qos statistics

Use the show qos statistics command to display QoS-related counters for a specified module.

show qos statistics {mod_num[/port_num]}

Syntax Description

mod_num

Number of the module.

/port_num

(Optional) Number of the port.

Defaults

This command has no default setting.

Command Types

Switch command.

Command Modes

Normal.

Usage Guidelines

This command is supported only on Catalyst 5000 family switches with Supervisor Engine II G or III G, or Supervisor Engine III or III F with the NFFC II.

In the output, the Threshold #:Packets dropped field lists each threshold and the number of packets dropped. For example, 1:0 pkt, 2:0 pkts indicates that thresholds 1 and 2 had 0 packets dropped.

Examples

This example shows how to display QoS statistics information for module 2, port 1:

Console> (enable) show qos statistics 2/1
On Transmit: Port 2/1 has 2 Queue(s) 2 Threshold(s)
Q #  Threshold #:Packets dropped
---  -----------------------------------------------
1    1:0 pkts , 2:0 pkts 
2    1:0 pkts , 2:0 pkts 
On Receive: Port 2/1 has 1 Queue(s) 4 Threshold(s)
Rx drop threshold counters are disabled for untrusted ports.
Q #  Threshold #:Packets dropped
---  -----------------------------------------------
1    1:0 pkts, 2:0 pkts, 3:0 pkts, 4:0 pkts
Console> (enable) 

Related Commands

set qos
set qos ip-filter
set qos mac-cos
set qos map
set qos router-mac
set qos wred-threshold

show radius

Use the show radius command to display configured RADIUS parameters.

show radius [noalias]

Syntax Description

noalias

(Optional) Keyword that forces the display to show IP addresses, not IP aliases.

Defaults

This command has no default setting.

Command Types

Switch command.

Command Modes

Normal.

Usage Guidelines

This command can be entered in Normal or Privileged mode, but the RADIUS key is displayed only if this command is entered in Privileged mode.

Examples

This example shows how to display RADIUS information:

Console> (enable) show radius
Login Authentication:	 Console Session  Telnet Session
---------------------  ---------------- ---------------
tacacs                 disabled         disabled
radius                 enabled(primary) enabled(primary)
local                  enabled          enabled
 
Enable Authentication: Console Session  Telnet Session
---------------------- ---------------- ---------------
tacacs                 disabled         disabled
radius                 enabled(primary) enabled(primary)
local                  enabled          enabled
 
Radius deadtime: 	0 minutes
Radius key: 	hello
Radius retransmit: 	3
Radius timeout: 	5 seconds
 
Radius-Server	       Status  	Auth-port Acct-port
------------------- ------- --------- ---------
198.32.67.9         	primary	 1645      1813
172.31.11.12                1645      1646
Console> (enable)

Related Commands

set qos
set radius key
set radius retransmit
set radius server
set radius timeout

show rgmp group

Use the show rgmp group command to display all multicast groups or the count of multicast groups that are joined by RGMP-capable routers.

show rgmp group [mac_addr] [vlan_id]

show
rgmp group count [vlan_id]

Syntax Description

mac_addr

(Optional) MAC destination address reserved for the use of RGMP packets.

vlan_id

(Optional) Number of the VLAN; valid values are from 1 to 1005.

Defaults

This command has no default setting.

Command Types

Switch command.

Command Modes

Normal.

Usage Guidelines

This command is supported by the Catalyst 5000 family switches.

Examples

This example displays all multicast groups joined by RGMP-capable routers:

Console> show rgmp group
 
Vlan          Dest MAC/Route Des    RGMP Joined Router Ports
---------------------------------------------------------------------
1             01-00-5e-00-01-28          5/1,5/15
1             01-00-5e-01-01-01          5/1
2             01-00-5e-27-23-70*         3/1,5/1
Total Number of Entries=3
 
`*'- Configured manually
Console>

This example displays the total number of entries of VLAN group 1 that are joined by RGMP-capable routers:

Console> show rgmp group count 1
RGMP enabled.
Total Number of Entries=2
Console> 

Related Commands

set rgmp
show rgmp statistics
clear rgmp statistics


hometocprevnextglossaryfeedbacksearchhelp
Posted: Sun Jun 11 11:27:48 PDT 2000