2
Use the set logging history command to set the size of the syslog history table.
set logging history syslog_history_table_size
Syntax Description
syslog_history_table_size Size of the syslog history table; valid values are 0 to 500.
Defaults
This command has no default setting.
Command Types
Switch command.
Command Modes
Privileged.
Examples
This example shows how to set the size of the syslog history table to 400:
Console> (enable) set logging history 400
System logging history table size set to <400>.
Console> (enable)
Related Commands
Use the set logging level command to set the facility and severity level used when logging system messages.
set logging level facility severity [default]
Syntax Description
facility Value for the type of system messages to capture. Facility types are shown in Table 2-3. severity Value for the severity level of system messages to capture. Severity level definitions are shown in Table 2-4. default (Optional) Keyword that specifies the logging level to apply to all sessions. If default is not used, the specified logging level applies only to the current session.
| Facility Name | Definition |
|---|---|
cdp | Cisco Discovery Protocol |
mcast | Multicast |
dtp | Dynamic Trunk Protocol |
dvlan | Dynamic VLAN |
earl | Encoded Address Recognition Logic |
fddi | Fiber Distributed Data Interface |
ip | Internet Protocol |
pruning | VTP pruning |
snmp | Simple Network Management Protocol |
spantree | Spanning-Tree Protocol |
sys | System |
tac | Terminal Access Controller |
tcp | Transmission Control Protocol |
telnet | Terminal Emulation Protocol |
tftp | Trivial File Transfer Protocol |
vtp | Virtual Terminal Protocol |
vmps | VLAN Membership Policy Server |
kernel | Kernel |
filesys | File System |
drip | Dual Ring Protocol |
pagp | Port Aggregation Protocol |
mgmt | Management |
mls | Multilayer Switching |
protfilt | Protocol Filter |
security | Security |
| Severity Level | Severity Type | Description |
|---|---|---|
0 | emergencies | System unusable |
1 | alerts | Immediate action required |
2 | critical | Critical condition |
3 | errors | Error conditions |
4 | warnings | Warning conditions |
5 | notifications | Normal bug significant condition |
6 | informational | Informational messages |
7 | debugging | Debugging messages |
Defaults
The switches ship with the following default configuration:
| Configuration Parameter | Defaults Setting |
|---|---|
system message logging to the console | enabled |
system message logging to Telnet sessions | enabled |
logging server | disabled |
syslog server | unconfigured |
server facility | LOCAL7 |
server severity | Warnings (4) |
logging buffer | 500 |
logging history size | 1 |
timestamp option | disabled |
facility/severity level for system messages | sys/5 |
Command Types
Switch command.
Command Modes
Privileged.
Examples
This example shows how to set the default system message logging severity level for the SNMP facility:
Console> (enable) set logging level snmp 2 default
System logging facility <snmp> set to severity 2(critical).
Console> (enable)
Related Commands
show logging
show logging buffer
Use the set logging server command to enable and disable system message logging to configured syslog servers and to add a syslog server to the system logging server table.
set logging server {enable | disable}
Syntax Description
enable Keyword that specifies to enable system message logging to configured syslog servers. disable Keyword that specifies to disable system message logging to configured syslog servers. ip_addr IP address of the syslog server to be added to the configuration. An IP alias or a host name that can be resolved through DNS can also be used. facility Keyword that specifies to set the type of system messages to capture. server_facility_parameter Value that specifies the logging facility of syslog server; valid values are local0, local1, local2, local3, local4, local5, local6, local7, and syslog. severity Keyword to set the severity level of system messages to capture. server_severity_level Value that specifies the severity level of system messages to capture; valid values are 0 through 7. Severity level definitions are shown in Table 2-4.
Defaults
By default, no syslog servers are configured to receive system messages.
Command Types
Switch command.
Command Modes
Privileged.
Examples
This example shows how to enable system message logging to the console:
Console> (enable) set logging server enable
System logging messages will be sent to the configured syslog servers.
Console> (enable)
This example shows how to add a syslog server to the system logging server table:
Console> (enable) set logging server 192.168.255.255
192.168.255.255 added to the System logging server table.
Console> (enable)
This example shows how to set the syslog server facility to local7:
Console> (enable) set logging server facility local7 System logging server facility set to <local7> Console> (enable)
This example shows how to set the syslog server severity level to 4:
Console> (enable) set logging server severity 4 System logging server severity set to <4> Console> (enable)
This example shows how to set the syslog history table size to 400:
Console> (enable) set logging history 400 System logging history table size set to <400> Console> (enable)
Related Commands
clear logging server
show logging
Use the set logging session command to enable or disable the sending of system logging messages to the current login session.
set logging session {enable | disable}
Syntax Description
enable Keyword that specifies to enable the sending of system logging messages to the current login session. disable Keyword that specifies to disable the sending of system logging messages to the current login session.
Defaults
By default, system message logging to the current login session is enabled.
Command Types
Switch command.
Command Modes
Privileged.
Examples
This example shows how to prevent system logging messages from being sent to the current login session:
Console> (enable) set logging session disable System logging messages will not be sent to the current login session. Console> (enable)
This example shows how to cause system logging messages to be sent to the current login session:
Console> (enable) set logging session enable System logging messages will be sent to the current login session. Console> (enable)
Related Commands
set logging buffer
set logging level
show logging
show logging buffer
Use the set logging timestamp command to enable or disable the timestamp display on system logging messages.
set logging timestamp {enable | disable}
Syntax Description
enable Keyword that specifies to enable the timestamp display. disable Keyword that specifies to disable the timestamp display.
Defaults
By default, system message logging timestamp is enabled.
Command Types
Switch command.
Command Modes
Privileged.
Examples
This example shows how to enable the timestamp display:
Console> (enable) set logging timestamp enable System logging messages timestamp will be enabled. Console> (enable)
This example shows how to disable the timestamp display:
Console> (enable) set logging timestamp disable System logging messages timestamp will be disabled. Console> (enable)
Related Commands
Use the set logout command to set the number of minutes until the system disconnects an idle session automatically.
set logout timeout
Syntax Description
timeout Number of minutes (0 to 10,000) until the system disconnects an idle session automatically. Setting the value to 0 disables the automatic disconnection of idle sessions.
Defaults
The default value is 20 minutes.
Command Types
Switch command.
Command Modes
Privileged.
Examples
This example shows how to set the number of minutes until the system disconnects an idle session automatically:
Console> (enable) set logout 20 Sessions will be automatically logged out after 20 minutes of idle time. Console> (enable)
This example shows how to disable the automatic disconnection of idle sessions:
Console> (enable) set logout 0 Sessions will not be automatically logged out. Console> (enable)
Use the set mls command to enable and disable IP or IPX MLS on the switch.
set mls {enable | disable} {ip | ipx}
Syntax Description
enable Keyword that specifies to enable MLS on the switch. disable Keyword that specifies to disable MLS on the switch. ip Keyword that specifies to specify IP MLS. ipx Keyword that specifies to specify IPX MLS.
Defaults
By default, IP MLS is enabled and IPX MLS is disabled.
Command Types
Switch command.
Command Modes
Privileged.
Usage Guidelines
This command is supported by the Catalyst 5000 family switches and the Catalyst 2926G series switches.
The ipx keyword is supported only on Catalyst 5000 family switches with Supervisor Engine II G or III G, or Supervisor Engine III or III F with the NFFC II.
If you do not specify the ip or ipx keyword, ip is assumed.
Examples
This example shows how to disable IP MLS on the switch:
Console> (enable) set mls disable ip IP Multilayer switching is disabled. Console> (enable)
This example shows how to enable IPX MLS on the switch:
Console> (enable) set mls enable ipx IPX Multilayer switching is enabled Console> (enable)
Related Commands
set mls nde
clear mls entry ip
clear mls entry ipx
clear mls include ip
clear mls include ipx
clear mls nde
clear mls statistics
show mls rp
Use the set mls agingtime command to configure the IP and IPX MLS entry aging time.
set mls agingtime {ip | ipx} agingtime
Syntax Description
ip Keyword that specifies IP MLS agingtime. ipx Keyword that specifies IPX MLS agingtime. agingtime (Optional) Aging time of MLS entries, in seconds.
Defaults
The default MLS entry aging time is set to 256 seconds.
Command Types
Switch command.
Command Modes
Privileged.
Usage Guidelines
This command is supported by the Catalyst 5000 family switches and the Catalyst 2926G series switches.
The ipx keyword is supported only on Catalyst 5000 family switches with Supervisor Engine II G or III G, or Supervisor Engine III or III F with the NFFC II.
If you do not specify the ip or ipx keyword, ip is assumed.
The agingtime must be specified as a multiple of 8 seconds in the range of 8 to 2024 seconds. If you enter a value for agingtime that is not a multiple of 8 seconds, the value is adjusted to the closest one. For example, 65 is adjusted to 64, while 127 is adjusted to 128.
Examples
This example shows how to set the IP MLS aging time to 512 seconds:
Console>(enable) set mls agingtime 512
IP Multilayer switching aging time set to 512 seconds.
Console> (enable)
Related Commands
clear mls entry ip
clear mls entry ipx
clear mls include ip
clear mls include ipx
clear mls nde
clear mls statistics
set mls agingtime fast
show mls rp
Use the set mls agingtime fast command to specify the MLS aging time of shortcuts to an MLS entry that has no more than pkt_threshold packets switched within fastagingtime seconds after it is created.
set mls agingtime fast fastagingtime pkt_threshold
Syntax Description
fastagingtime Valid values are multiples of 8 to any value in the range of 0 to 128 seconds. 0 disables fast aging. If a value is not specified, the default value is used. pkt_threshold Valid values are 0, 1, 3, 7, 15, 31, 63, and 127 packets. If a value is not specified, the default value is used.
Defaults
The default fastagingtime is 0, no fast aging. The default pkt_threshold is 0.
Command Types
Switch command.
Command Modes
Privileged.
Usage Guidelines
This command is supported by the Catalyst 5000 family switches and the Catalyst 2926G series switches.
This command is not available for IPX MLS.
When you set the fastagingtime value, it can be configured as multiples of 8 to any value in the range of 0 to 128 seconds.
The default pkt_threshold is 0. It can be configured as one of the 0, 1, 3, 7, 15, 31, 63, and 127 (the values picked for efficient aging). If fastagingtime is not configured exactly the same among these values, it is adjusted to the closest one. A typical value for fastagingtime and pkt_threshold is 32 seconds and 0 packet, respectively (it means no packet switched within 32 seconds after the entry created).
Agingtime applies to an MLS entry that has no more than pkt_threshold packets switched within fastagingtime seconds after it is created. A typical example is the MLS entry destined to or sourced from a DNS or TFTP server. This entry may never be used again after it is created. For example, only one request goes to a server and one reply returns from the server, and then the connection is closed.
The fastagingtime option is used to purge entries associated with very short flows, such as DNS and TFTP.
We recommend that you keep the number of MLS entries in the MLS cache below 32K. If the number of MLS entries is more than 32K, some flows (less than 1 percent) are sent to the router.
To keep the number of MLS cache entries below 32K, decrease the aging time. Aging time can be decreased up to 8 seconds. If your switch has a lot of short flows that are used by only a few packets, then you can use fast aging.
If cache entries continue to exceed 32K, decrease the normal aging time in 64-second increments from the 256-second default.
Examples
This example shows how to use the set mls agingtime fast command to set the agingtime:
Console>(enable) set mls agingtime fast 32 0 Multilayer switching fast aging time set to 32 seconds for entries with no more than 0 packet switched. Console> (enable)
Related Commands
set mls nde
clear mls entry ip
clear mls entry ipx
clear mls include ip
clear mls include ipx
clear mls nde
clear mls statistics
show mls rp
show mls statistics
Use the set mls flow command to specify the minimum flow mask used for MLS. This command is needed to collect statistics for the supervisor engine module.
set mls flow {destination | destination-source | full}![]() |
Caution Use this command carefully. This command purges all existing shortcuts and affects the number of active shortcuts. This command can increase the cache usage and increase the load on the router. |
![]() |
Caution Be extremely careful if you enter this command on a switch that already has a large number of shortcuts (greater than 16K). |
![]() |
Caution Do not place this command in scripts that are frequently executed---changing the MLS flow mask purges all MLS cache entries. |
Syntax Description
destination Keyword that specifies to set the minimum flow mask to destination flow. destination-source Keyword that specifies to set the minimum flow mask to source flow. full Keyword that specifies to set the minimum flow mask to an extended access list.
Defaults
If there are no access lists on any MLS-RP, the flow mask is set to destination flow.
Command Types
Switch command.
Command Modes
Privileged.
Usage Guidelines
This command is supported by the Catalyst 5000 family switches and the Catalyst 2926G series switches.
This command specifies the minimum MLS flow mask. Depending on the MLS-RP configuration, the actual flow mask used might be more specific than the specified minimum flow mask. For example, if you configure the minimum flow mask to destination-source, but an MLS-RP interface is configured with IP extended access lists, the actual flow mask used will be full.
If you configure a more specific flow mask (for example, destination-source or full), the number of active flow entries increases. To limit the number of active flow entries, you might need to decrease the MLS aging time.
This command is intended to be used for gathering very detailed statistics at the protocol port level; for example, when NetFlow data is exported to an RMON2 probe.
Examples
These examples show how to specify that only expired flows to subnet 171.69.194.0 are exported:
Console> (enable) set mls flow destinationConfigured flow mask is set to destination flow.Console> (enable) Console> (enable) set mls flow destination-sourceConfigured flow mask is set to destination-source flow.Console> (enable) Console> (enable) set mls flow fullConfigured flow mask is set to full flow.Console> (enable)
Related Commands
clear mls entry ip
clear mls entry ipx
clear mls include ip
clear mls include ipx
clear mls nde
clear mls statistics
show mls rp
set mls agingtime
Use the set mls include command to specify routers to add to the IP MLS-RP include list.
set mls include {ip | ipx} ip_addr1 [ip_addr2...]
Syntax Description
ip Keyword that specifies the IP MLS-RP include list. ipx Keyword that specifies the IPX MLS-RP include list. ip_addr1 IP address or DNS host name of the first router to include. ip_addr2... (Optional) IP addresses or DNS host names of additional routers to include (you can include up to 16 routers to participate in IP MLS).
Defaults
If a Catalyst 5000 family RSM or RSFC is installed in the switch, it is added to the MLS-RP include list automatically.
Command Types
Switch command.
Command Modes
Privileged.
Usage Guidelines
This command is supported by the Catalyst 5000 family switches and the Catalyst 2926G series switches.
The ipx keyword is supported only on Catalyst 5000 family switches with Supervisor Engine II G or III G, or Supervisor Engine III or III F with the NFFC II.
If you do not specify the ip or ipx keyword, ip is assumed.
You must use the IP address or DNS host name of the router to add to the IP or IPX MLS-RP include list. You cannot specify the router IPX address.
You can specify the IP addresses of multiple MLS-RPs on the same command line. Up to 16 MLS-RPs can be selected to participate in MLS.
The switch does not process MLSP messages from routers that are not in the MLS-RP include list.
Examples
This example shows how to add a router to the IP MLS-RP include list:
Console> (enable) set mls include ip 172.170.2.1
IP Multilayer switching is enabled for router 172.170.2.1
Console> (enable)
This example shows how to add a router to the IPX MLS-RP include list:
Console> (enable) set mls include ipx 172.170.2.1 IPX Multilayer switching is enabled for router 172.170.2.1 Console> (enable)
Related Commands
set mls nde
clear mls entry ip
clear mls entry ipx
clear mls include ip
clear mls include ipx
clear mls nde
clear mls statistics
show mls rp
show mls statistics
Use the set mls multicast command to enable and disable IP multicast MLS on the switch.
set mls multicast {enable | disable}
Syntax Description
enable Keyword that specifies to enable IP multicast MLS on the switch. disable Keyword that specifies to disable IP multicast MLS on the switch.
Defaults
The default is that IP multicast MLS is disabled.
Command Types
Switch command.
Command Modes
Privileged.
Usage Guidelines
This command is supported only on Catalyst 5000 family switches with Supervisor Engine II G or III G, or Supervisor Engine III or III F with the NFFC II.
You must enable one of the Layer 2 multicast protocols (CGMP, IGMP snooping, or GMRP) on the switch before you enable IP multicast MLS.
Examples
This example shows how to enable IP multicast MLS on the switch:
Console> (enable) set mls multicast enable
Multilayer switching for Multicast is enabled for this device.
Console> (enable)
Related Commands
show mls multicast entry
set mls multicast include
clear mls multicast include
clear mls multicast statistics
Use the set mls multicast include command to specify routers to add to the IP MMLS-RP include list.
set mls multicast include ip_addr
Syntax Description
ip_addr IP address or DNS host name of the router to include.
Defaults
The default is no routers are in the IP MMLS-RP include list.
Command Types
Switch command.
Command Modes
Privileged.
Usage Guidelines
This command is supported by the Catalyst 5000 family switches.
You can specify only one router IP address at a time. You can configure a maximum of two internal or directly attached participating routers.
The switch does not process MLSP messages from routers that are not in the MMLS-RP include list.
Examples
This example shows how to add a router to the MMLS-RP include list:
Console> (enable) set mls multicast include 172.170.2.1
Multilayer switching enabled for router 172.170.2.1
Console> (enable)
Related Commands
show mls multicast entry
clear mls multicast include
clear mls multicast statistics
clear mls nde
Use the set mls nde command to enable and disable NDE on the switch and to configure the switch to export statistics to the specified collector.
set mls nde {disable | enable}
Syntax Description
disable Keyword that specifies to disable NDE. enable Keyword that specifies to enable NDE. collector_ip IP address of the collector if DNS is enabled. udp_port_num Number of the UDP port to receive the exported statistics. flow Keyword that specifies to add filtering to NDE. destination (Optional) Keyword that specifies the destination IP address. ip_addr_spec (Optional) Full IP address or a subnet address in these formats: ip_subnet_addr, ip_addr/subnet_mask, or ip_addr/#subnet_mask_bits. source (Optional) Keyword that specifies the source IP address. protocol (Optional) Keyword that specifies the protocol type. protocol (Optional) Protocol type; valid values can be 0, TCP, UDP, ICMP, or a decimal number for other protocol families. 0 indicates "do not care." If the protocol is not TCP or UDP, we recommend that you set the dst-port port_number and src-port port_number values to 0; otherwise, no flows are displayed. src-port (Optional) Keyword that specifies the number of the source port. Used with dst-port to specify the port pair if the protocol is TCP or UDP. 0 indicates "do not care." If the protocol is not TCP or UDP, we recommend that you set the src-port value to 0; otherwise, no flows are displayed. port_number (Optional) Number of the TCP/UDP port (decimal). dst-port (Optional) Keyword that specifies the number of the destination port. Used with src-port to specify the port pair if the protocol is TCP or UDP. 0 indicates "do not care." If the protocol is not TCP or UDP, we recommend that you set the dst-port value to 0; otherwise, no flows are displayed.
Defaults
All expired flows are exported until the filter is specified explicitly.
Command Types
Switch command.
Command Modes
Privileged.
Usage Guidelines
This command is supported by the Catalyst 5000 family switches and the Catalyst 2926G series switches.
Before you use the set mls nde command for the first time, you must configure the host to collect the MLS statistics. The host name and UDP port number are saved in NVRAM, and you do not need to specify them. If you specify a host name and UDP port, values in NVRAM overwrite the old values. Collector's values in NVRAM do not clear when NDE is disabled; this command configures the collector, but does not enable NDE automatically.
The set mls nde enable command enables NDE, exporting statistics to the preconfigured collector.
The set mls nde flow command adds filtering to the NDE. Expired flows matching the specified criteria are exported. These values are stored in NVRAM. They are not cleared when NDE is disabled. If any option is not specified in this command, it is treated as a wildcard. The NDE filter in NVRAM does not clear when NDE is disabled.
Use the following syntax to specify an IP subnet address:
If the protocol value is not set to TCP or UDP, we recommend you set the dst_port and src_port values to 0; otherwise, no flows will be displayed.
Examples
These examples show how to use the set mls nde command set to configure NDE:
Console> (enable) set mls nde Stargate 120 Netflow data export not enabled. Netflow data export to port 120 on 172.20.15.1(Stargate) Console> (enable) Console>(enable) set mls nde enable Netflow data export enabled. Netflow data export to port 120 on 172.20.15.1 (Stargate) Console> (enable) Console> (enable) set mls nde disabled Netflow data export disabled. Console> (enable) Console> (enable) set mls nde flow destination 171.69.194.140/24 Netflow data export: destination filter set to 171.69.194.0/24 Console> (enable) Console> (enable) set mls nde flow destination 171.69.194.140 Netflow data export: destination filter set to 171.69.194.140/32 Console> (enable) Console>(enable) set mls nde flow destination 171.69.194.140/24 source 171.69.173.5/24 Netflow data export: destination filter set to 171.69.194.0/24 Netflow data export: source filter set to 171.69.173.0/24 Console>(enable) console> (enable) set mls nde flow source 171.69.194.140 protocol 51 Netflow data export: source filter set to 171.69.194.140/32 Netflow data export: protocol filter set to 51. Console> (enable) Console>(enable) set mls nde flow dst-port 23 Netflow data export: destination port filter set to 23. Console>(enable) Console>(enable) set mls nde flow source 171.69.194.140 dst-port 23 Netflow data export: destination port filter set to 23 Netflow data export: source filter set to 171.69.194.140/32 Console>(enable)
Related Commands
clear mls entry ip
clear mls entry ipx
clear mls include ip
clear mls include ipx
clear mls nde
clear mls statistics
show mls rp
show mls statistics
set mls agingtime
set mls agingtime fast
Use the set mls statistics protocol command to specify protocols and ports for which to gather MLS statistics.
set mls statistics protocol protocol port
Syntax Description
protocol Number of the protocol. port Number of the port.
Defaults
The default is no protocols are specified for statistics collection.
Command Types
Switch command.
Command Modes
Privileged.
Usage Guidelines
This command is supported by the Catalyst 5000 family switches and the Catalyst 2926G series switches.
You can configure a maximum of 64 ports on which to collect protocol statistics. Use the show mls statistics command to view MLS statistics for the specified protocols.
Examples
This example shows how to specify a protocol and port for which to gather MLS statistics:
Console>(enable) set mls statistics protocol 17 1934 Protocol 17 port 1934 is added to protocol statistics list. Console> (enable)
Related Commands
Use the set module disable command to disable a module.
set module disable mod_num
Syntax Description
mod_num Number of the module. You can specify a series of modules by entering a comma between each module number (for example, 2,3,5). You can specify a range of modules by entering a dash between module numbers (for example, 2-5).
Defaults
The default configuration has all modules enabled.
Command Types
Switch command.
Command Modes
Privileged.
Usage Guidelines
Avoid disabling a module when you are connected through a Telnet session; if you disable the module that contains the port through which your Telnet session was established, you will disconnect your Telnet session.
If there are no other network connections to the switch, you must connect to the switch through the console port to reenable the module.
Examples
This example shows how to disable module 3 when connected through the console port:
Console> (enable) set module disable 3 Module 3 disabled. Console> (enable)
This example shows how to disable module 2 when connected through a Telnet session:
Console> (enable) set module disable 2 This command may disconnect your telnet session. Do you want to continue (y/n) [n]? y Module 2 disabled.
Related Commands
Use the set module enable command to enable a module.
set module enable mod_num
Syntax Description
mod_num Number of the module to enable.
Defaults
The default setting has all modules enabled.
Command Types
Switch command.
Command Modes
Privileged.
Usage Guidelines
If an individual port on a module was previously disabled, enabling the module does not enable the disabled port.
Examples
This example shows how to enable module 2:
Console> (enable) set module enable 2 Module 2 enabled. Console> (enable)
Related Commands
Use the set module name command to set the name for a module.
set module name mod_num [mod_name]
Syntax Description
mod_num Number of the module. mod_name (Optional) Name to assign to the module.
Defaults
The default configuration has no module names configured for any modules.
Command Types
Switch command.
Command Modes
Privileged.
Usage Guidelines
If you do not specify a mod_name value, any previously specified name is cleared.
Module names configured using the set module name command are displayed in the output of the show module command and other commands.
Examples
This example shows how to set the name for module 1 to Supervisor:
Console> (enable) set module name 1 Supervisor Module name set. Console> (enable)
Related Commands
Use the set multicast router command to manually configure a port as a multicast router port.
set multicast router mod_num/port _num
Syntax Description
mod_num/port _num Number of the module and the port.
Defaults
By default, no ports are configured as multicast router ports.
Command Types
Switch command.
Command Modes
Privileged.
Usage Guidelines
When you enable CGMP or IGMP snooping, the ports to which a multicast-capable router is attached are identified automatically. The set multicast router command allows you to configure multicast router ports statically.
Examples
This example shows how to configure a multicast router port:
Console> (enable) set multicast router 3/1
Port 3/1 added to multicast router port list.
Console> (enable)
Related Commands
clear multicast router
set cgmp
set igmp
show multicast router
show multicast group count
Use the set ntp authentication command to enable or disable the NTP authentication feature.
set ntp authentication {enable | disable}
Syntax Description
enable Keyword that specifies to enable NTP authentication. disable Keyword that specifies to disable NTP authentication.
Defaults
The default is NTP authentication.
Command Types
Switch command.
Command Modes
Privileged.
Examples
This example shows how to enable NTP authentication:
Console> (enable)set ntp authentication enableNTP authentication feature enabled.At least one trusted key must be set for NTP to work.Console> (enable)
This example shows how to disable NTP authentication:
Console> (enable)set ntp authentication disableNTP authentication feature disabled.Console> (enable)
Related Commands
Use the set ntp broadcastclient command to enable or disable NTP broadcast-client mode.
set ntp broadcastclient {enable | disable}
Syntax Description
enable Keyword that specifies to enable NTP broadcast-client mode. disable Keyword that specifies to disable NTP broadcast-client mode.
Defaults
The default setting for this command is disabled.
Command Types
Switch command.
Command Modes
Privileged.
Usage Guidelines
You can configure NTP in either broadcast-client mode or client mode. The broadcast-client mode assumes that a broadcast server, such as a router, sends time-of-day information regularly to the switch.
Examples
This example shows how to enable NTP broadcast client:
Console> (enable) set ntp broadcastclient enable NTP Broadcast Client mode enabled. Console> (enable)
This example shows how to disable NTP broadcast client:
Console> (enable) set ntp broadcastclient disable NTP Broadcast Client mode disabled. Console> (enable)
Related Commands
Use the set ntp broadcastdelay command to configure a time-adjustment factor so the switch can receive broadcast packets.
set ntp broadcastdelay microseconds
Syntax Description
microseconds Estimated round-trip time, in microseconds, for NTP broadcasts. Allowable range is from 1 to 999999.
Defaults
By default, the NTP broadcast delay is set to 3000.
Command Types
Switch command.
Command Modes
Privileged.
Examples
This example shows how to set the NTP broadcast delay to 4000 microseconds:
Console> (enable) set ntp broadcastdelay 4000 NTP broadcast delay set to 4000 microseconds. Console> (enable)
Related Commands
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Sun Jun 11 11:23:13 PDT 2000