Use the show multicast protocols status command to display multicast protocol configuration status.
show multicast protocols statusThis command has no keywords or arguments.
This command has no default setting.
Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch
Catalyst 2980G switch
Switch command.
Normal.
This example show how to display the multicast protocol configuration:
Console> show multicast protocols status CGMP disabled IGMP enabled IGMP fastleave disabled RGMP enabled GMRP disabled Console> (enable)
clear multicast router
set multicast router
show multicast group
show multicast group count
Use the show multicast router command to display which ports have CGMP-capable routers assigned to them.
show multicast router [cgmp | igmp | rgmp] [mod_num/port_num] [vlan_id]
cgmp | (Optional) Keyword that specifies to display only the configuration information learned through CGMP. |
igmp | (Optional) Keyword that specifies to display only the configuration information learned through IGMP. |
rgmp | (Optional) Keyword that specifies to display only the configuration information learned through RGMP. |
mod_num | (Optional) Number of the module. |
port_num | (Optional) Number of the port on the module. |
vlan_id | (Optional) Number of the VLAN. |
This command has no default setting.
Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch
Catalyst 2980G switch
Switch command.
Normal.
The igmp keyword is not supported by the Catalyst 4000 family and 2948G switches.
The Catalyst 2948G and 2980G switches are fixed configuration switches. Ports are located on module 2 for the 2948G and on modules 2 and 3 for the 2980G; for this reason, if you enter mod_num/port_num 1/N, an error message will be displayed.
This example show how to display the multicast router configuration:
Console> show multicast router Port Vlan ---------- ---------------- Total Number of Entries = 0 '*' - Configured '+' - RGMP-capable Console> (enable)
This example show how to display the multicast router configuration for VLAN 99:
Console> show multicast router 99
Port Vlan
---------- ----------------
Total Number of Entries = 0
'*' - Configured
Console>
This example shows how to display only the configuration information learned through CGMP:
Console> show multicast router cgmp CMGP Feature is enabled. Console>
Table 2-37 describes the fields in the show multicast router command output.
| Field | Description |
|---|---|
Port | Port through which a multicast router can be reached. |
Vlan | VLAN associated with the port. |
* | Status of whether the port was manually configured as a multicast router port. |
+ | States whether the port is RGMP capable. |
CGMP enabled | Status of whether CGMP is enabled or disabled. |
IGMP enabled | Status of whether IGMP is enabled or disabled. |
Total Number of Entries | Total number of entries in the table that match the criteria specified by the command. |
clear multicast router
set cgmp
set igmp
set igmp fastleave
set multicast router
show multicast group count
Use the show netstat command to display the currently active network connections and to list statistics for the various protocols in the TCP/IP.
show netstat [tcp | udp | ip | icmp | routes | stats | interfaces]
tcp | (Optional) Keyword that specifies to show TCP statistics. |
udp | (Optional) Keyword that specifies to show UDP statistics. |
ip | (Optional) Keyword that specifies to show IP statistics. |
icmp | (Optional) Keyword that specifies to show ICMP statistics. |
routes | (Optional) Keyword that specifies to show the IP routing table. |
stats | (Optional) Keyword that specifies to show all statistics for TCP, UDP, IP, and ICMP. |
interfaces | (Optional) Keyword that specifies to show interface statistics. |
This command has no default setting.
Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch
Catalyst 2980G switch
Switch command.
Normal.
Counter information for me1 is viewed by entering the show netstat interfaces command.
This example shows how to display the current active network connections:
Console> show netstat Active Internet connections (including servers) Proto Recv-Q Send-Q Local Address Foreign Address (state) tcp 0 128 172.20.25.142.23 171.68.10.75.44720 ESTABLISHED tcp 0 0 *.7161 *.* LISTEN tcp 0 0 *.23 *.* LISTEN udp 0 0 *.* *.* udp 0 0 *.161 *.* udp 0 0 *.123 *.* Console>
This example shows how to display TCP statistics:
Console> show netstat tcp
tcp:
5122 packets sent
4642 data packets (102292 bytes)
28 data packets (6148 bytes) retransmitted
434 ack-only packets (412 delayed)
0 URG only packets
0 window probe packets
1 window update packet
17 control packets
7621 packets received
4639 acks (for 103883 bytes)
69 duplicate acks
0 acks for unsent data
3468 packets (15367 bytes) received in-sequence
12 completely duplicate packets (20 bytes)
0 packets with some dup. data (0 bytes duped)
4 out-of-order packets (0 bytes)
0 packets (0 bytes) of data after window
0 window probes
0 window update packets
0 packets received after close
0 discarded for bad checksums
0 discarded for bad header offset fields
0 discarded because packet too short
6 connection requests
6 connection accepts
10 connections established (including accepts)
11 connections closed (including 1 drop)
2 embryonic connections dropped
4581 segments updated rtt (of 4600 attempts)
28 retransmit timeouts
0 connections dropped by rexmit timeout
0 persist timeouts
66 keepalive timeouts
63 keepalive probes sent
3 connections dropped by keepalive
Console>
Table 2-38 describes the fields in the show netstat tcp command output.
| Field | Description |
|---|---|
packets sent | Total number of TCP packets sent. |
data packets (bytes) | Number of TCP data packets sent and the size of those packets in bytes. |
data packets (bytes) retransmitted | Number of TCP data packets retransmitted and the size of those packets in bytes. |
ack-only packets (delayed) | Number of TCP acknowledgment-only packets sent and the number of those packets delayed. |
packets received | Total number of TCP packets received. |
acks (for x bytes) | Number of TCP acknowledgments received and the total bytes acknowledged. |
duplicate acks | Number of duplicate TCP acknowledgments received. |
acks for unsent data | Number of TCP acknowledgments received for data that was not sent. |
packets (bytes) received in-sequence | Number of TCP packets (and the size in bytes) received in sequence. |
completely duplicate packets (bytes) | Number of duplicate TCP packets (and the size in bytes) received. |
packets with some dup. data (bytes duped) | Number of TCP packets received with duplicate data (and the number of bytes of duplicated data). |
out-of-order packets (bytes) | Number of out-of-order TCP packets (and the size in bytes) received. |
packets (bytes) of data after window | Number of TCP packets (and the size in bytes) received outside of the specified data window. |
discarded for bad checksums | Number of TCP packets received and discarded that failed the checksum. |
discarded because packet too short | Number of TCP packets received and discarded that were truncated. |
connection requests | Total number of TCP connection requests sent. |
connection accepts | Total number of TCP connection accepts sent. |
connections established (including accepts) | Total number of TCP connections established, including those for which a connection accept was sent. |
connections closed (including x drops) | Total number of TCP connections closed, including dropped connections. |
retransmit timeouts | Number of timeouts that occurred when a retransmission was attempted. |
connections dropped by rexmit timeout | Number of connections dropped due to retransmission timeouts. |
keepalive timeouts | Number of keepalive timeouts that occurred. |
keepalive probes sent | Number of TCP keepalive probes sent. |
connections dropped by keepalive | Number of connections dropped. |
This example shows how to display UDP statistics:
Console> show netstat udp
udp:
0 incomplete headers
0 bad data length fields
0 bad checksums
0 socket overflows
1116 no such ports
Console>
Table 2-39 describes the fields in the show netstat udp command output.
| Field | Description |
|---|---|
incomplete headers | Number of UDP packets received with incomplete packet headers. |
bad data length fields | Number of UDP packets received with a data length field that did not match the actual length of the packet payload. |
bad checksums | Number of UDP packets received that failed the checksum. |
socket overflows | Number of socket overflows. |
no such ports | Number of UDP packets received destined for nonexistent ports. |
This example shows how to display IP statistics:
Console> show netstat ip
ip:
76894 total packets received
0 bad header checksums
0 with size smaller than minimum
0 with data size < data length
0 with header length < data size
0 with data length < header length
0 fragments received
0 fragments dropped (dup or out of space)
0 fragments dropped after timeout
0 packets forwarded
0 packets not forwardable
0 redirects sent
Console>
Table 2-40 describes the fields in the show netstat ip command output.
| Field | Description |
|---|---|
total packets received | Total number of IP packets received. |
bad header checksums | Number of received IP packets that failed the checksum. |
with size smaller than minimum | Number of received IP packets that were smaller than the minimum IP packet size. |
fragments received | Number of IP packet fragments received. |
fragments dropped (dup or out of space) | Number of received IP packet fragments that were dropped because of duplicate data or buffer overflow. |
fragments dropped after timeout | Number of received IP packet fragments that were dropped. |
packets forwarded | Number of forwarded IP packets. |
packets not forwardable | Number of IP packets that the switch did not forward. |
This example shows how to display ICMP statistics:
Console> show netstat icmp
icmp:
Redirect enabled
0 calls to icmp_error
0 errors not generated 'cuz old message was icmp
Output histogram:
echo reply: 1001
1 message with bad code fields
0 messages < minimum length
0 bad checksums
0 messages with bad length
Input histogram:
echo reply: 12
destination unreachable: 3961
echo: 1001
1001 message responses generated
Console>
Table 2-41 describes the fields in the show netstat icmp command output.
| Field | Description |
|---|---|
Redirect enabled | Status of whether ICMP redirection is enabled or disabled. |
Output histogram | Frequency distribution statistics for output ICMP packets. |
echo reply | Number of output echo reply ICMP packets. |
messages with bad code fields | Number of ICMP packets with an invalid code field. |
messages < minimum length | Number of ICMP packets with less than the minimum packet length. |
bad checksums | Number of ICMP packets that failed the checksum. |
messages with bad length | Number of ICMP packets with an invalid length. |
Input histogram | Frequency distribution statistics for input ICMP packets. |
echo reply | Number of input echo reply ICMP packets. |
destination unreachable | Number of input destination unreachable ICMP packets. |
echo | Number of input echo ICMP packets. |
message responses generated | Number of ICMP message responses the system generated. |
This example shows how to display the IP routing table:
Console> show netstat routes DESTINATION GATEWAY FLAGS USE INTERFACE default 172.16.1.201 UG 6186 sc0 172.16.0.0 172.16.25.142 U 6383 sc0 default default UH 0 sl0 Console>
Table 2-42 describes the fields in the show netstat routes command output.
| Field | Description |
|---|---|
DESTINATION | Destination IP address or network. |
GATEWAY | Next hop to the destination. |
INTERFACE | Interface out of which packets to the destination should be forwarded. |
This example shows how to display interface statistics:
Console> show netstat interface Interface InPackets InErrors OutPackets OutErrors sl0 0 0 0 0 sc0 33 0 117192 0 me1 2 0 57075 0 Interface Rcv-Octet Xmit-Octet --------- -------------------- -------------------- sc0 2389 0 me1 1172 0 sl0 0 0 Interface Rcv-Unicast Xmit-Unicast --------- -------------------- -------------------- sc0 28 0 me1 28 0 sl0 0 0 Console>
Table 2-43 describes the fields in the show netstat interface command output.
| Field | Description |
|---|---|
Interface | Interface number (sl0 is the SLIP interface; sc0 is the in-band interface; me1 is the out-of-band interface). |
InPackets | Number of input packets on the interface. |
InErrors | Number of input errors on the interface. |
OutPackets | Number of output packets on the interface. |
OutErrors | Number of output errors on the interface. |
Rcv-Octet | Number of octet frames received on the port. |
Xmit-Octet | Number of octet frames transmitted on the port. |
Rcv-Unicast | Number of unicast frames received on the port. |
Xmit-Unicast | Number of unicast frames transmitted on the port. |
Use the show ntp command to display the current NTP status.
show ntpThis command has no arguments or keywords.
This command has no default setting.
Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch
Catalyst 2980G switch
Switch command.
Normal.
This example shows how to display the current NTP status:
Console> show ntp Current time: Thu Jan 15 1999, 11:19:03 pst Timezone: 'pst', offset from UTC is -8 hours Summertime: 'pst', enabled Last NTP update: Broadcast client mode: enabled Broadcast delay: 3000 microseconds Client mode: disabled Authentication: enabledNTP-Server Server Key---------------------------------------- ----------172.20.33.140 1722033140172.20.33.114 1722033114Console>
The following output appears in the show ntp command output when entered from privileged mode:
Key Number Mode Key String---------- --------- --------------------------------1234 trusted 324234234231722033140 untrusted termserv-amConsole>
Table 2-44 describes the fields in the show ntp command output.
| Field | Description |
|---|---|
Current time | Current system time. |
Timezone | Time zone and the offset in hours from UTC. |
Summertime | Time zone for daylight saving time and whether the daylight saving time adjustment is enabled or disabled. |
Last NTP update | Time of the last NTP update. |
Broadcast client mode | Status of whether NTP broadcast-client mode is enabled or disabled. |
Broadcast delay | Configured NTP broadcast delay. |
Client mode | Status of whether NTP client mode is enabled or disabled. |
NTP-Server | List of configured NTP servers. |
clear ntp key
clear ntp server
set ntp broadcastclient
set ntp broadcastdelay
set ntp client
set ntp key
set ntp server
Use the show port command to display port status and counters.
show port [mod_num[/port_num]]
mod_num | (Optional) Number of the module. If you do not specify a number, the ports on all modules are shown. |
/port_num | (Optional) Number of the port on the module. If you do not specify a number, all the ports on the module are shown. |
This command has no default setting.
Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch
Catalyst 2980G switch
Switch command.
Normal.
In the status field for the Catalyst 5000 family, 4000 family, 2926G series, 2948G, and 2980G switch ports, the following applies:
For Catalyst 4000 family switches, in the show port command display, the combination of the 32-port module (WS-X4502) and 4-port 100FX daughtercard results in an entry that lists 36 ports. If the uplink daughtercard is not installed, only ports 1 through 32 are listed.
Although me1 resides on the supervisor engine module for the Catalyst 4000 family and 2948G switches, me1 port information is not displayed by the show module or show port CLI commands.
The Catalyst 2948G and 2980G switches are fixed configuration switches. Ports are located on module 2 for the 2948G and on modules 2 and 3 for the 2980G; for this reason, if you enter mod_num/port_num 1/N, an error message will be displayed.
This example shows how to display the status and counters for port 1 on module 3 (Catalyst 5000 family and 2926G series switches):
Console> (enable) show port 3/1Port Name Status Vlan Level Duplex Speed Type----- ------------------ ---------- ---------- ------ ------ ----- ------------3/1 connected 1 normal half 100 100BaseFX MMPort Security Secure-Src-Addr Last-Src-Addr Shutdown Trap IfIndex----- -------- ----------------- ----------------- -------- -------- -------3/1 disabled No disabled 58Port Broadcast-Limit Broadcast-Drop-------- --------------- --------------3/1 - 0Port Status Channel Channel Neighbor Neighbormode status device port----- ---------- --------- ----------- ------------------------- ----------3/1 connected off not channelPort Align-Err FCS-Err Xmit-Err Rcv-Err UnderSize----- ---------- ---------- ---------- ---------- ---------3/1 3384 16 0 0 0Port Single-Col Multi-Coll Late-Coll Excess-Col Carri-Sen Runts Giants----- ---------- ---------- ---------- ---------- --------- --------- ---------3/1 0 0 0 0 0 521 0Last-Time-Cleared--------------------------Fri Apr 16 1999, 10:00:46Console>
This example shows how to display the status and counters for port 2 on a Catalyst 4000 family or 2948G switch:
Console> show port 2Port Name Status Vlan Level Duplex Speed Type----- ------------------ ---------- ---------- ------ ------ ----- ------------2/1 connected 1 normal full 1000 1000BaseSX2/2 connected 1 normal full 1000 1000BaseSX2/3 notconnect 1 normal full 1000 No GBIC2/4 notconnect 1 normal full 1000 No GBIC2/5 notconnect 1 normal full 1000 No GBIC2/6 notconnect 1 normal full 1000 No GBICPort Security Secure-Src-Addr Last-Src-Addr Shutdown Trap IfIndex----- -------- ----------------- ----------------- -------- -------- -------2/1 disabled No disabled 902/2 disabled No disabled 912/3 disabled No disabled 922/4 disabled No disabled 932/5 disabled No disabled 942/6 disabled No disabled 95Port Send FlowControl Receive FlowControl RxPause TxPause Unsupportedadmin oper admin oper opcodes----- -------- -------- -------- -------- ------- ------- -----------2/1 desired off off off 0 0 02/2 desired off off off 0 0 02/3 desired off off off 0 0 02/4 desired off off off 0 0 02/5 desired off off off 0 0 02/6 desired off off off 0 0 0Port Align-Err FCS-Err Xmit-Err Rcv-Err UnderSize----- ---------- ---------- ---------- ---------- ---------2/1 - 0 1 0 02/2 - 8 2 8 02/3 - 0 0 0 02/4 - 0 0 0 02/5 - 0 0 0 02/6 - 0 0 0 0Port Single-Col Multi-Coll Late-Coll Excess-Col Carri-Sen Runts Giants----- ---------- ---------- ---------- ---------- --------- --------- ---------2/1 0 0 0 0 1 0 02/2 0 0 0 0 1 0 02/3 0 0 0 0 0 0 02/4 0 0 0 0 0 0 02/5 0 0 0 0 0 0 02/6 0 0 0 0 0 0 0Last-Time-Cleared--------------------------Fri Apr 9 1999, 18:54:17Console>
Table 2-45 describes the possible fields (depending on the port type queried) in the show port command output.
| Field | Description |
|---|---|
Port | Module and port number. |
Name | Name (if configured) of the port. |
Status | Status of the port. For the Catalyst 5000 family and 2926G series switches, possible displays are connected, notconnect, connecting, standby, faulty, inactive, shutdown, disabled, or monitor; for the Catalyst 4000 family and 2948G switches, possible displays are connected, notconnected, faulty, remfault, disable, remdisable, configerr, remcfgerr, and disagree. |
Vlan | VLANs to which the port belongs. |
Duplex | Duplex setting for the port (auto, full, fdx, half, hdx, a-half, a-hdx, a-full, or a-fdx). |
Speed | Speed setting for the port (auto, 10, 100, 155, a-10, a-100, 4, 16, a-14,or a-16). |
Type1 | Port type, for example, 100BaseFX MM, 100BaseFX SM, 10/100BaseTX, or RSM. |
Security | Status of whether port security is enabled or disabled. |
Secure-Src-Addr | Secure MAC address for the security enabled port. |
Last-Src-Addr | Source MAC address of the last packet received by the port. |
Shutdown | Status of whether the port was shut down because of security. |
Trap | Status of whether port trap is enabled or disabled. |
IfIndex | Number of the ifIndex. |
Broadcast-Limit | Broadcast threshold configured for the port. |
Broadcast-Drop | Number of broadcast/multicast packets dropped because the broadcast limit for the port was exceeded. |
Send admin | Flow-control administration. Possible settings: on indicates the local port sends flow control to the far end; off indicates the local port does not send flow control to the far end; desired indicates the local end sends flow control to the far end if the far end supports it. |
FlowControl oper | Flow-control operation. Possible setting: disagree indicates the two ports could not agree on a link protocol. |
Receive admin | Flow-control administration. Possible settings: on indicates the local port requires the far end to send flow control; off indicates the local port does not allow the far end to send flow control; desired indicates the local end allows the far end to send flow control. |
FlowControl oper | Flow-control operation. Possible setting: disagree indicates the two ports could not agree on a link protocol. |
RxPause | Number of Pause frames received. |
TxPause | Number of Pause frames transmitted. |
Unsupported Opcodes | Number of unsupported operating codes. |
Align-Err | Number of frames with alignment errors (frames that do not end with an even number of octets and have a bad CRC) received on the port. |
FCS-Err | The number of valid size frames with FCS errors but no framing errors. |
Xmit-Err | Number of transmit errors that occurred on the port (indicating that the internal transmit buffer is full). |
Rcv-Err | Number of receive errors that occurred on the port (indicating that the internal receive buffer is full). |
UnderSize | Number of received frames less than 64 octets long (but are otherwise well-formed). |
Single-Coll | Number of times one collision occurred before the port transmitted a frame to the media successfully. |
Multi-Coll | Number of times multiple collisions occurred before the port transmitted a frame to the media successfully. |
Late-Coll | Number of late collisions (collisions outside the collision domain). |
Excess-Col | Number of excessive collisions that occurred on the port (indicating that a frame encountered 16 collisions and was discarded). |
Carri-Sen | Number of times the port sensed a carrier (to determine whether the cable is currently being used). |
Runts | Number of received runt frames (frames that are smaller than the minimum IEEE 802.3 frame size) on the port. |
Giants | Number of received giant frames (frames that exceed the maximum IEEE 802.3 frame size) on the port. |
Last-Time-Cleared | Last time the port counters were cleared. |
Auto-Part | The number of times the port entered the auto-partition state due to excessive consecutive collisions. |
Data-rate mismatch | The number of valid size frames experienced overrun or underrun. |
Src-addr change | The number of times the last source address changed. |
Good-bytes | The total number of octets in frames with no error. |
Short-event | The number of times activity with a duration less than the ShortEventMax Time (74-82 bit times) is detected. |
| 1These fields will change according to the system configuration. |
Use the show port broadcast command to display broadcast information.
show port broadcast [mod_num[/port_num]]
mod_num | (Optional) Number of the module. |
/port_num | (Optional) Number of the port on the module. |
This command has no default setting.
Catalyst 5000 family switches
Catalyst 2926G series switches
Switch command.
Normal.
On the 1000BaseX switching module, when you specify a port for broadcast suppression, the traffic is suppressed only in the network-to-Catalyst 5000 family and 2926G series switches bus direction.
If you do not specify a mod_num, the ports on all modules are shown.
If you do not specify a /port_num, all the ports on the module are shown.
This example shows how to display broadcast information for port 2 on module 1:
Console> show port broadcast 1/2 Port Broadcast-Limit Broadcast-Drop -------- --------------- -------------- 1/2 75.25% - Console>
Table 2-46 describes the possible fields in the show port broadcast command output.
| Field | Description |
|---|---|
Port | Module and port number. |
Broadcast-Limit | Broadcast threshold configured for the port in percent or packets per second. |
Broadcast-Drop | Number of broadcast/multicast packets dropped because the broadcast limit for the port was exceeded. |
Use the show port capabilities command to display the capabilities of the modules and ports in a switch.
show port capabilities [mod_num[/port_num]]
mod_num | (Optional) Number of the module. |
/port_num | (Optional) Number of the port on the module. |
This command has no default setting.
Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch
Catalyst 2980G switch
Switch command.
Normal.
If you do not specify a mod_num, the ports on all modules are shown.
If you do not specify a /port_num, all the ports on the module are shown.
The Catalyst 2948G and 2980G switches are fixed configuration switches. Ports are located on module 2 for the 2948G and on modules 2 and 3 for the 2980G; for this reason, if you enter mod_num/port_num 1/N, an error message will be displayed.
This example shows how to show the port capabilities for module 1, port 1:
Console> (enable) show port capabilities 1/1 Model WS-X5530 Port 1/1 Type 10/100BaseTX Speed auto,10,100 Duplex half,full Trunk encap type 802.1Q,ISL Trunk mode on,off,desirable,auto,nonegotiate Channel 1/1-2,1/1-4 Broadcast suppression percentage(0-100) Flow control receive-(off,on),send-(off,on) Security yes Membership static,dynamic Fast start yes QOS scheduling rx-(none),tx-(none) CoS rewrite yes ToS rewrite IP-Precedence Rewrite yes UDLD Capable Voice vlan no
Table 2-47 describes the possible fields (depending on the type of port queried) and the values in the show port capabilities command output.
| Field | Description |
|---|---|
Model | Module model number. |
Port | Module number and port number. |
Type1 | Port type, for example, 100BaseFX MM, 100BaseFX SM, or 10/100BaseTX. |
Speed1 | Port speed setting (for example, auto, 100, or 1000). |
Duplex | Duplex mode (half, full, auto, fdx, hdx, or no). |
Trunk encap type | Trunk encapsulation type (ISL, 802.1Q, 802.10, or no). |
Trunk mode | Trunk administrative status of the port (on, off, auto, desirable, nonegotiate, or no). |
Channel | Status of which ports can form a channel group. The ports are shown in mod_num/port_num format. For example, 3/1-2 indicates module 3, ports 1 and 2. Also, any ports in range [mod/1-mod/high_port] or no ports may be indicated. |
Broadcast suppression | Number of packets-per-second (pps) of broadcast/multicast traffic allowed on the port (0-150000) or the percentage of total available bandwidth that can be used by broadcast/multicast traffic (0-100). |
Flow control | Flow-control options you can set (receive-[off, on, desired], send-[off, on, desired], or no). |
Security | Status of whether port security is enabled (yes, no). |
Membership | Method of membership assignment of a port or range of ports to a VLAN (static, dynamic). |
Fast Start | Status of whether the spanning-tree port fast-start feature on the port is enabled (yes, no). |
QoS Scheduling | (rx-(none),tx-(none)). |
CoS Rewrite | Status of whether the port supports COS rewrite (yes, no). |
ToS Rewrite | Status of whether the port supports TOS rewrite (IP-Precedence). |
Rewrite | Status of whether the port supports inline rewrite (yes, no). |
UDLD | Status of whether the port supports UDLD (Capable, Not capable). |
Voice Vlan | Status of whether the port supports voice or VLAN (yes, no). |
| 1These fields will change depending on the system configuration. |
set port channel
set port broadcast
set port security
set port speed
set spantree portfast
set trunk
Use the show port cdp command to display port CDP enable state and message interval on the port.
show port cdp [mod_num[/port_num]]
mod_num | (Optional) Number of the module. |
/port_num | (Optional) Number of the port on the module. |
This command has no default setting.
Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch
Catalyst 2980G switch
Switch command.
Normal.
If you do not specify a mod_num, the ports on all modules are shown.
If you do not specify a /port_num, all the ports on the module are shown.
The Catalyst 2948G and 2980G switches are fixed configuration switches. Ports are located on module 2 for the 2948G and on modules 2 and 3 for the 2980G; for this reason, if you enter mod_num/port_num 1/N, an error message will be displayed.
This example shows how to display CDP information for all ports:
Console> show port cdp CDP :enabled Message Interval :60 Hold Time :180 Port CDP Status -------- ---------- 2/1 enabled 2/2 enabled 5/1 enabled 5/2 enabled 5/3 enabled 5/4 enabled 5/5 enabled 5/6 enabled 5/7 enabled 5/8 enabled Console>
Table 2-48 describes the fields in the show port cdp command output.
| Field | Description |
|---|---|
Port | Module and port number. |
CDP Status | CDP status of the port (enabled, disabled). |
Message-Interval | Interval between CDP message exchange with neighbor. |
Use the show port channel command to display EtherChannel information for a specific module or port.
show port channel [mod_num[/port_num]] [statistics | info [spantree | trunk | protocol | gmrp | gvrp | qos]]
mod_num | (Optional) Number of the module. |
port_num | (Optional) Number of the port. |
statistics | (Optional) Keyword that specifies to display EtherChannel PAgP statistics. |
info | (Optional) Keyword that specifies to display EtherChannel configuration information. |
spantree | (Optional) Keyword that specifies to display only spanning-tree-related configuration information. |
trunk | (Optional) Keyword that specifies to display only VLAN-trunk-related configuration information. |
protocol | (Optional) Keyword that specifies to display only protocol-filtering-related configuration information. |
gmrp | (Optional) Keyword that specifies to display only GMRP-related configuration information. |
gvrp | (Optional) Keyword that specifies to display only GVRP-related configuration information. |
qos | (Optional) Keyword that specifies to display only QoS-related configuration information. |
This command has no default setting.
Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch
Catalyst 2980G switch
Switch command.
Normal.
If the module and port are not specified, EtherChannel information is shown for all channeling ports on all modules.
This example shows how to display Fast EtherChannel information for port 1/4:
Console> show port channel 1/4
Port Status Channel Admin Ch
Mode Group Id
----- ---------- -------------------- ----- -----
1/1 connected auto silent 22 769
1/2 connected auto silent 22 769
1/3 connected auto silent 22 769
1/4 connected auto silent 22 769
----- ---------- -------------------- ----- -----
Port Device-ID Port-ID Platform
----- ------------------------------- ------------------------- ----------------
1/1 069003103(5500) 3/13 WS-C5500
1/2 069003103(5500) 3/14 WS-C5500
1/3 069003103(5500) 3/15 WS-C5500
1/4 069003103(5500) 3/16 WS-C5500
----- ------------------------------- ------------------------- ----------------
Console>
This example shows how to display PAgP packet statistics:
Console> show port channel statistics
Port Admin PAgP Pkts PAgP Pkts PAgP Pkts PAgP Pkts PAgP Pkts PAgP Pkts
Group Transmitted Received InFlush RetnFlush OutFlush InError
----- ------- ----------- --------- --------- --------- --------- ---------
1/1 22 5063 5073 0 0 0 0
1/2 22 5062 5075 0 0 0 0
1/3 22 5068 5077 0 0 0 0
1/4 22 5076 5066 0 0 0 0
----- ------- ----------- --------- --------- --------- --------- ---------
Console>
This example shows how to display EtherChannel configuration information:
Console> show port channel info
Switch Frame Distribution Method: mac both
Port Status Channel Admin Channel Speed Duplex Vlan
mode group id
----- ---------- -------------------- ----- ------- ----- ------ ----
1/1 connected auto silent 22 769 a-100 a-full 1
1/2 connected auto silent 22 769 a-100 a-full 1
1/3 connected auto silent 22 769 a-100 a-full 1
1/4 connected auto silent 22 769 a-100 a-full 1
----- ---------- -------------------- ----- ------- ----- ------ ----
Port ifIndex Oper-group Neighbor Oper-Distribution PortSecurity/
Oper-group Method Dynamic port
----- ------- ---------- ---------- ----------------- -------------
1/1 626 1 mac both
1/2 626 1 mac both
1/3 626 1 mac both
1/4 626 1 mac both
----- ------- ---------- ---------- ----------------- -------------
Port Device-ID Port-ID Platform
----- ------------------------------- ------------------------- ----------------
1/1 069003103(5500) 3/13 WS-C5500
1/2 069003103(5500) 3/14 WS-C5500
1/3 069003103(5500) 3/15 WS-C5500
1/4 069003103(5500) 3/16 WS-C5500
----- ------------------------------- ------------------------- ----------------
Port Trunk-status Trunk-type Trunk-vlans
----- ------------ ------------- -----------------------------------------------
1/1 trunking n-isl 1-1005
1/2 trunking n-isl 1-1005
1/3 trunking n-isl 1-1005
1/4 trunking n-isl 1-1005
----- ------------ ------------- -----------------------------------------------
Port Portvlancost-vlans
----- --------------------------------------------------------------------------
1/1
1/2
1/3
1/4
----- --------------------------------------------------------------------------
Port Port Portfast Port Port
priority vlanpri vlanpri-vlans
----- -------- -------- ------- ------------------------------------------------
1/1 32 disabled 0
1/2 32 disabled 0
1/3 32 disabled 0
1/4 32 disabled 0
----- -------- -------- ------- ------------------------------------------------
Port IP IPX Group
----- -------- -------- --------
1/1 on auto-on auto-on
1/2 on auto-on auto-on
1/3 on auto-on auto-on
1/4 on auto-on auto-on
----- -------- -------- --------
Port GMRP GMRP GMRP
status registration forwardAll
----- -------- ------------ ----------
1/1 enabled normal disabled
1/2 enabled normal disabled
1/3 enabled normal disabled
1/4 enabled normal disabled
----- -------- ------------ ----------
Port GVRP GVRP GVRP
status registeration applicant
----- -------- ------------- ---------
1/1 disabled normal normal
1/2 disabled normal normal
1/3 disabled normal normal
1/4 disabled normal normal
----- -------- ------------- ---------
Port Qos-Tx Qos-Rx Qos-Trust Qos-DefCos
PortType PortType Type
----- -------- -------- ------------ ----------
1/1 - - untrusted 0
1/2 - - untrusted 0
1/3 - - untrusted 0
1/4 - - untrusted 0
----- -------- -------- ------------ ----------
Console>
Table 2-49 describes the fields in the show port channel output.
| Field | Description |
|---|---|
Port | Module and port number |
Status | Port connection status |
Channel mode | EtherChannel mode |
Admin Group | EtherChannel administrative group |
Ch Id | EtherChannel ID |
Device-ID | Serial number and hostname of neighboring device |
Port-ID | Connected port number on neighboring device |
Platform | Neighboring device platform |
Table 2-50 describes the fields in the show port channel statistics output.
| Field | Description |
|---|---|
Port | Port number |
Admin Group | EtherChannel administrative group |
PAgP Pkts Transmitted | Number of PAgP packets transmitted on the port |
PAgP Pkts Received | Number of PAgP packets received on the port |
PAgP Pkts InFlush | Number of PAgP flush packets received |
PAgP Pkts RetnFlush | Number of PAgP flush packets returned |
PAgP Pkts OutFlush | Number of PAgP flush packets transmitted |
PAgP Pkts InError | Number of PAgP error packets received |
Table 2-51 describes the fields in the show port channel info output.
| Field | Description |
|---|---|
Switch Frame Distribution Method | Frame distribution method for all EtherChannels on the switch |
Port | Port number |
Status | Port connection status |
Channel mode | EtherChannel mode |
Admin group | EtherChannel administrative group |
Channel id | EtherChannel ID |
Speed | Port speed |
Duplex | Port duplex |
Vlan | Port VLAN membership |
if-index | Interface index number |
Oper-group | Capability of the group |
Neighbor Oper-group | Device ID of the neighboring device with which the port is channeling |
Chan cost | EtherChannel spanning-tree port cost |
Oper-Distribution Method | EtherChannel frame distribution method |
PortSecurity/Dynamic Port | Status of whether the port is secure or dynamic |
Device-ID | Serial number and hostname of neighboring device |
Port-ID | Connected port number on neighboring device |
Platform | Neighboring device platform |
Trunk-status | VLAN trunking mode |
Trunk-type | VLAN trunk encapsulation type |
Trunk-vlans | Allowed VLAN list for the trunk |
Portvlancost-vlans | Spanning-tree port-VLAN cost and associated VLAN IDs |
Port priority | Spanning-tree port priority |
Portfast | Spanning-tree PortFast enable state |
Port vlanpri-vlans | Spanning-tree port-VLAN priority and associated VLAN IDs |
IP | IP protocol filtering mode |
IPX | IPX protocol filtering mode |
Group | Group protocol filtering mode |
GMRP status | GMRP enable state |
GMRP registration | GMRP registration mode |
GMRP forwardAll | GMRP forward-all enable status |
GVRP status | GVRP enable state |
GVRP registration | GVRP registration mode |
GVRP applicant | GVRP applicant mode |
Qos-Tx | Transmit queue and threshold port type |
Qos-Rx | Receive queue and threshold port type |
Qos-Trust | QoS port trust |
QoS-DefCos | QoS default CoS |
set channel cost
set channel vlancost
set port channel
show channel
show channel group
Use the show port counters command to show all the counters for a port.
show port counters [mod_num/port_num]
mod_num | (Optional) Number of the module for which to show port counter information. |
/port_num | (Optional) Number of the port on the module for which to show port counter information. |
This command has no default setting.
Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch
Catalyst 2980G switch
Switch command.
Normal.
If you do not specify a mod_num, the ports on all modules are shown.
If you do not specify a /port_num, all the ports on the module are shown.
The Catalyst 2948G and 2980G switches are fixed configuration switches. Ports are located on module 2 for the 2948G and on modules 2 and 3 for the 2980G; for this reason, if you enter mod_num/port_num 1/N, an error message will be displayed.
This example shows the output of the show port counters command:
Console> (enable) show port counters
Port Align-Err FCS-Err Xmit-Err Rcv-Err Broad-Limit Broad-Drop
---- ---------- ---------- ---------- ---------- ----------- ----------
1/1 0 0 0 0 - 0
1/2 0 0 0 0 - 0
4/1 0 0 0 0 10000 p/s 0
4/2 0 0 0 0 100 p/s 53728
4/3 0 0 0 0 - 0
4/4 0 0 0 0 11.50 % 52
Port Single-Col Multi-Coll Late-Coll Excess-Col Carri-Sens Runts Giants
---- ---------- ---------- --------- ---------- ---------- ----- ------
1/1 0 0 0 0 0 0 -
1/2 0 0 0 0 0 0 -
4/1 0 0 0 0 0 0 -
4/2 0 0 0 0 0 0 -
4/3 0 0 0 0 0 0 -
4/4 0 0 0 0 0 0 -
Ler
Port CE-State Conn-State Type Neig Con Est Alm Cut Lem-Ct Lem-Rej-Ct Tl-Min
----- -------- ---------- ---- ---- --------------- ---------- ---------- ------
3/1 isolated connecting A U no 9 9 7 0 0 102
3/2 isolated connecting B U no 9 8 7 0 0 40
Last-Time-Cleared
--------------------------
Wed Apr 10 1996, 14:59:51
Console> (enable)
Table 2-52 describes the possible fields (depending on the port type queried) in the show port counters command output.
| Field | Description |
|---|---|
Port | Module and port number. |
Align-Err | Number of frames with alignment errors (frames that do not end with an even number of octets and have a bad CRC) received on the port. |
FCS-Err | Number of frame check sequence errors that occurred on the port. |
Xmit-Err | Number of transmit errors that occurred on the port (indicating that the internal transmit buffer is full). |
Rcv-Err | Number of receive errors that occurred on the port (indicating that the internal receive buffer is full). |
UnderSize | Number of received frames less than 64 octets long (but are otherwise well formed). |
Broadcast-Limit | Broadcast threshold configured for the port in percent or packets per second. |
Broadcast-Drop | Number of broadcast/multicast packets dropped because the broadcast limit for the port was exceeded. |
Single-Coll | Number of times one collision occurred before the port successfully transmitted a frame to the media. |
Multi-Coll | Number of times multiple collisions occurred before the port successfully transmitted a frame to the media. |
Late-Coll | Number of late collisions (collisions outside the collision domain). |
Excess-Col | Number of excessive collisions that occurred on the port (indicating that a frame encountered 16 collisions and was discarded). |
Carri-Sen | Number of times the port sensed a carrier (to determine whether the cable is currently being used). |
Runts | Number of received runt frames (frames that are smaller than the minimum IEEE 802.3 frame size) on the port. |
Giants | Number of received giant frames (frames that exceed the maximum IEEE 802.3 frame size) on the port. |
CE-State | Connection entity status. |
Conn-State | Connection state of the port, as follows:
|
Type | Type of port, such as A---A port and B---B port. |
Neig | Type of port attached to this port. The neighbor can be one of these types:
|
Ler Con | Status of whether the port is currently in a LER condition. |
Est | Estimated LER. |
Alm | LER at which a link connection exceeds the LER alarm threshold. |
Cut | LER cutoff value (the LER at which a link connection is flagged as faulty). |
Lem-Ct | Number of LEM errors received on the port. |
Lem-Rej-Ct | Number of times a connection was rejected because of excessive LEM errors. |
Tl-Min | TL-min value (the minimum time to transmit a FDDI PHY line state) before advancing to the next PCM state. |
Last-Time-Cleared | Last time the port counters were cleared. |
Use the show port filter command to view MAC addresses and protocol filters that have been configured on the Token Ring module ports.
show port filter [mod_num] [canonical]
mod_num | (Optional) Number of the module. |
canonical | (Optional) Keyword that specifies the MAC address display in canonical format. |
/port_num | Number of the port on the module. |
mac_addr | MAC address contained in the packets to be filtered. You need to enter this address in canonical format (00-11-33-44-55) or in noncanonical format (00:11:22:33:44:55). |
By default, MAC addresses are shown in noncanonical format.
Catalyst 5000 family switches
Switch command.
Normal.
This example shows how to display the filters configured for a port on the Token Ring module:
Console> show port filter 3/1
Port Mac-Addr Type
----- ----------------- ------
3/1 00:00:00:00:00:00 deny
00:00:00:00:00:00 deny
00:00:00:00:00:00 deny
00:00:00:00:00:00 deny
00:00:00:00:00:00 deny
00:00:00:00:00:00 deny
Port Protocol Type
----- ----------------- ------
3/1 0x8038 deny
0xf0f0 deny
Table 2-53 describes the fields in the show port filter command output.
| Field | Description |
Port | Module and port number. |
MAC-Addr | MAC address contained in packets to be filtered. |
Type | Type of MAC address filter configured. Possible types are deny (block any packet containing a specific MAC address) or permit (allow any packet containing a specific MAC address). |
Protocol | Types of protocols that you want to filter. |
Type | Type of protocol filter configured. Possible types are deny (block any packet containing a specific protocol type) or permit (allow any packet containing a specific protocol type). |
clear port filter
set port filter
Use the show port flowcontrol command to display per-port status information and statistics related to flow control.
show port flowcontrol [mod_num[/port_num]]
mod_num | (Optional) Number of the module. |
/port_num | (Optional) Number of the port on the module. If you do not specify a number, filters configured on all the ports on the module are shown. |
This command has no default setting.
Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch
Catalyst 2980G switch
Switch command.
Normal.
The Catalyst 2948G and 2980G switches are fixed configuration switches. Ports are located on module 2 for the 2948G and on modules 2 and 3 for the 2980G; for this reason, if you enter mod_num/port_num 1/N, an error message will be displayed.
This example shows how to display the flow-control port status and statistics:
Console> show port flowcontrol Port Send-Flowcontrol Receive-Flowcntl RxPause TxPause Admin Oper Admin Oper ----- ---------------- ---------------- ------- ------ 3/1 on disagree on disagree 0 0 3/2 off off off off 0 0 3/3 desired on desired off 10 10 Console>
Table 2-54 describes the fields in the show port flowcontrol command output.
| Field | Description |
Port | Module and port number. |
Send-Flowcontrol- | Flow-control administration. Possible settings: on indicates the local port sends flow control to the far end; off indicates the local port does not send flow control to the far end; desired indicates the local end sends flow control to the far end if the far end supports it. |
Send-Flowcontrol- | Flow-control operation. Possible setting: disagree indicates the two ports could not agree on a link protocol. |
Receive-Flowcntl- | Flow-control administration. Possible settings: on indicates the local port requires the far end to send flow control; off indicates the local port does not allow the far end to send flow control; desired indicates the local end allows the far end to send flow control. |
Receive-Flowcntl- | Flow-control operation. Possible setting: disagree indicates the two ports could not agree on a link protocol. |
RxPause | Number of Pause frames received. |
TxPause | Number of Pause frames transmitted. |
Use the show port ifindex command to view ifIndex information on a per-port or per-module basis.
show port ifindex [mod_num]
mod_num | (Optional) Number of the module. |
port_num | Number of the port. |
This command has no default settings.
Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch
Catalyst 2980G switch
Switch command.
Normal.
The Catalyst 2948G and 2980G switches are fixed configuration switches. Ports are located on module 2 for the 2948G and on modules 2 and 3 for the 2980G; for this reason, if you enter mod_num/port_num 1/N, an error message will be displayed.
This example shows how to display ifIndex information for all the ports:
Console> show port ifindex Port ifIndex ----- ------- 1/1 3 1/2 4 3/1 383 3/2 384 4/1 385 4/2 386 4/3 387 4/4 388 4/5 389 4/6 390 4/7 391 4/8 392 4/9 393 4/10 394 4/11 395 4/12 396 4/13 397 Console>
Use the show port negotiation command to display the link negotiation protocol setting for the specified port.
show port negotiation [mod_num[/port_num]]
mod_num | (Optional) Number of the module. |
/port_num | (Optional) Number of the port on the module. |
This command has no default setting.
Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch
Catalyst 2980G switch
Switch command.
Normal.
The Catalyst 2948G and 2980G switches are fixed configuration switches. Ports are located on module 2 for the 2948G and on modules 2 and 3 for the 2980G; for this reason, if you enter mod_num/port_num 1/N, an error message will be displayed.
This command is supported on Gigabit Ethernet and some Fast Ethernet ports. If the port does not support the command, the following message appears (where N/N is the module and port number):
Feature not supported on Port N/N.
This example shows how to display the link negotiation protocol settings on module 3, port 1:
Console> show port negotiation 3/1 Port Link Negotiation ------- -------------------- 3/1 enabled Console>
show port flowcontrol
set port negotiation
Use the show port protocol command to view protocol filters configured on the ports.
show port protocol [mod_num[/port_num]]
mod_num | (Optional) Number of the module. |
/port_num | (Optional) Number of the port on the module. |
This command has no default setting.
Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch
Catalyst 2980G switch
Switch command.
Normal.
If you do not specify a /port_num, filters configured on all the ports on the module are shown.
The Catalyst 2948G and 2980G switches are fixed configuration switches. Ports are located on module 2 for the 2948G and on modules 2 and 3 for the 2980G; for this reason, if you enter mod_num/port_num 1/N, an error message will be displayed.
This example shows how to view protocol filters on configured ports:
Console> show port protocol Port Vlan IP IP Hosts IPX IPX Hosts Group Group Hosts -------- ---------- -------- -------- -------- --------- -------- ----------- 1/1 1 on 0 on 0 on 0 1/2 1 on 0 on 0 on 0 2/1 1 on 3 auto-on 0 auto-on 0 2/2 1 on 0 on 0 on 0 2/3 1 on 0 on 0 on 0 2/4 1 on 0 on 0 on 0 2/5 1 on 0 on 0 on 0 2/6 1 on 0 on 0 on 0 2/7 1 on 0 on 0 on 0 2/8 1 on 0 on 0 on 0 2/9 1 on 0 on 0 on 0 2/10 1 on 0 on 0 on 0 Console>
Use the show port qos command to display QoS-related information for a specific port or all ports on a specific module.
show port qos mod_num[/port_num]
mod_num | Number of the module. |
port_num | (Optional) Number of the port. |
This command has no default setting.
Catalyst 5000 family switches
Switch command.
Normal.
This command is supported only on Catalyst 5000 family switches with Supervisor Engine II G or III G, or Supervisor Engine III or III F with the NFFC II.
This example shows how to display QoS-related information on module 4, port 1:
Console> show port qos 4/1QoS feature :EnabledTx port type :1q4tNVRAM Runtime Ext-Trust Ext-CosPort CoS CoS----- --- --- --------- --------4/1 7 7 trust-cos 7Console>
This example shows how to display QoS-related information for all ports on module 3:
Console> (enable) show port qos 3
QoS feature :Enabled
Tx port type :2q2t
NVRAM Runtime
Port CoS CoS
----- --- ---
3/1 2 2
3/2 2 2
3/3 2 2
3/4 2 2
3/5 2 2
3/6 2 2
3/7 2 2
3/8 2 2
set qos
set qos ip-filter
set qos mac-cos
set qos map
set qos router-mac
set qos wred-threshold
Use the show port security command to view port security configuration information and statistics.
show port security mod/ports... [statistics]
mod | Number of the module. |
ports... | Number of the ports. |
statistics | Keyword that specifies to display security statistics. |
By default configuration information is displayed.
Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch
Catalyst 2980G switch
Switch command.
Privileged.
If you issue this command against a Token Ring port, the following message is generated:
Feature not supported for Module x.
This command is not supported by the three-port Gigabit Ethernet switching module (WS-X5403).
The Catalyst 2948G and 2980G switches are fixed configuration switches. Ports are located on module 2 for the 2948G and on modules 2 and 3 for the 2980G; for this reason, if you enter mod_num/port_num 1/N, an error message will be displayed.
This example shows how to display port security configuration information on a secured port and the output:
Console> (enable) show port security 4/1
Port Security Violation Shutdown-Time Age-Time Maximum-Addrs Trap IfIndex
----- -------- --------- ------------- -------- ------------- -------- -------
4/1 enabled shutdown 120 1440 25 disabled 3
Port Secure-Src-Addrs Age-Left Last-Src-Addr Shutdown Shutdown-Time-Left
---- ----------------- -------- ----------------- -------- ------------------
4/1 00-11-22-33-44-55 4 00-11-22-33-44-55 No -
00-10-14-da-77-f1 100
This example shows the output on a port that has experienced a security violation:
Console> (enable) show port security 4/1
Port Security Violation Shutdown-Time Age-Time Maximum-Addrs Trap IfIndex
----- -------- --------- ------------- -------- ------------- -------- -------
4/1 enabled shutdown 120 600 25 disabled 3
Port Secure-Src-Addrs Age-Left Last-Src-Addr Shutdown Shutdown-Time-Left
---- ----------------- -------- ----------------- -------- ------------------
4/1 00-11-22-33-44-55 60 00-11-22-33-44-77 Yes -
00-10-14-da-77-f1 200
00-11-22-33-44-66 200
The example below shows that port 4/2 has been shut down and that the timeout left is 60 minutes before the port will be reenabled:
Console> (enable) show port security 4/1
Port Security Violation Shutdown-Time Age-Time Maximum-Addrs Trap IfIndex
----- -------- --------- ------------- -------- ------------- -------- -------
4/1 enabled restrict 120 600 25 disabled 3
Port Secure-Src-Addrs Age-Left Last-Src-Addr Shutdown Shutdown-Time-Left
---- ----------------- -------- ----------------- -------- ------------------
4/1 00-11-22-33-44-55 60 00-11-22-33-44-77 Yes -
00-10-14-da-77-ff
set port security
clear port security
Use the show port security command to view port security configuration statistics.
show port security statistics mod | mod/port [system]
mod | Number of the module. |
mod/port | Number of the module and port. |
system | (Optional) Keyword that specifies to display systemwide configuration statistics. |
Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch
Catalyst 2980G switch
Switch command.
Privileged.
If you issue this command against a Token Ring port, the following message is generated:
Feature not supported for Module x.
This command is not supported by the three-port Gigabit Ethernet switching module (WS-X5403).
The Catalyst 2948G and 2980G switches are fixed configuration switches. Ports are located on module 2 for the 2948G and on modules 2 and 3 for the 2980G; for this reason, if you enter mod_num/port_num 1/N, an error message will be displayed.
This example shows how to display port security configuration information on a secured port and the output:
Console> (enable) show port security statistics system Module 1: Total ports: 4 Total MAC address(es): 4 Total global address space used (out of 1024): 0 Status: installed
Module 3: Total ports: 24 Total MAC address(es): 24 Total global address space used (out of 1024): 0 Status: installed Module 8: Module does not support port security feature Module 10: Module does not support port security feature Console> (enable)
set port security
clear port security
Use the show port status command to display port status information.
show port status [mod_num[/port_num]]
mod_num | (Optional) Number of the module. |
/port_num | (Optional) Number of the port on the module. |
This command has no default setting.
Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch
Catalyst 2980G switch
Switch command.
Normal.
The Catalyst 2948G and 2980G switches are fixed configuration switches. Ports are located on module 2 for the 2948G and on modules 2 and 3 for the 2980G; for this reason, if you enter mod_num/port_num 1/N, an error message will be displayed.
If you do not specify a mod_num, the ports on all modules are shown.
If you do not specify a /port_num, all the ports on the module are shown.
This example shows how to display port status information for all ports:
Console> show port statusPort Name Status Vlan Level Duplex Speed Type----- ------------------ ---------- ---------- ------ ------ ----- ------------1/1 connected 523 normal half 100 100BaseTX 1/2 notconnect 1 normal half 100 100BaseTX 2/1 connected trunk normal half 400 Route Switch 3/1 notconnect trunk normal full 155 OC3 MMF ATM 5/1 notconnect 1 normal half 100 FDDI 5/2 notconnect 1 normal half 100 FDDI Console>
Table 2-55 describes the fields in the show port status command output.
| Field | Description |
|---|---|
Port | Module and port number. |
Name | Name (if configured) of the port. |
Status | Status of the port (connected, notconnect, connecting, standby, faulty, inactive, shutdown, disabled, or monitor). |
Vlan | VLANs to which the port belongs. |
Level | Level setting for the port (normal or high). |
Duplex | Duplex setting for the port (auto, full, fdx, half, hdx, a-half, a-hdx, a-full, or a-fdx). |
Speed | Speed setting for the port (auto, 10, 100,155, a-10, a-100, 4, 16, a-14,or a-16). |
Type1 | Port type, for example, 10BaseT, 10BaseFL MM, 100BaseTX, 100BaseT4, 100BaseFX MM, 100BaseFX SM, 10/100BaseTX, TokenRing, FDDI, CDDI, or RSM. |
| 1These fields will change according to the system configuration. |
Use the show proc command to display CPU, memory allocation, and process utilization information.
show proc [cpu | mem] {mod_num}
cpu | (Optional) Keyword that specifies CPU information. |
mem | (Optional) Keyword that specifies malloced memory information. |
mod_num | Number of the module. |
This command has no default setting.
Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch
Catalyst 2980G switch
Switch command.
Privileged.
This command can only be entered in privileged mode. If you do not specify cpu or mem, process information is displayed.
The mem keyword allows you to display malloced memory information, such as how much each process has allocated and how much memory it has freed can be obtained.
This example shows how to display CPU information:
Console> (enable)show proc cpuCPU utilization for five seconds: 1.44%one minute: 1.96%five minutes: 1.02%PID Runtime(ms) Invoked uSecs 5Sec 1Min 5Min TTY Process--- ----------- ---------- -------- ------- ------- ------- --- ---------------1 0 0 0 98.56% 98.04% 98.98% 0 Kernel and Idle2 4 38 1000 0.00% 0.00% 0.00% 0 Flash MIB Updat3 1421 5547 466000 0.00% 0.00% 0.00% 0 SynDiags4 166212 519822 19000 0.22% 0.00% 0.00% 0 SynConfig5 185 94681 1000 0.00% 0.00% 0.00% 0 Statuspoll6 472 297 0 0.00% 0.00% 0.00% 0 SWPoll64bCnt7 90 3548211 1000 0.00% 0.00% 0.00% 0 SL_TASK8 113 141960 106000 0.00% 0.00% 0.00% 0 RedundantTaskConsole> (enable)
This example shows how to display process information:
Console> (enable)show proc memMemory Used: 1281040Freed: 9597104Total: 10878144PID TTY Allocated Freed Holding Process---------- ---------- ---------- ---------- ---------- ---------------1 0 711008 2832 708176 Kernel and Idle2 0 240 0 240 Flash MIB Updat3 0 284128 283712 416 SynDiags4 0 211856 1920 209936 SynConfig5 0 96 0 96 Statuspoll6 0 4944 4352 592 SWPoll64bCnt7 0 80 0 80 SL_TASK8 0 2272 1952 320 RedundantTaskConsole> (enable)
This example shows how to display process utilization information:
Console> (enable)show procCPU utilization for five seconds: 0.44%one minute: 1.00%five minutes: 1.00%PID Q T PC Runtime(ms) Invoked uSecs Stacks TTY Process--- -- -- ---------- ----------- -------- ------- --------- --- ---------------1 1 rd 0x8041ab80 0 0 0 1580/6144 0 Kernel and Idle2 1 st 0x8041adfc 4 38 1000 1604/6144 0 Flash MIB Updat3 2 st 0x8041adfc 1421 5547 466000 3364/6144 0 SynDiags4 1 si 0x8041adfc 166438 520543 19000 1764/6144 0 SynConfig5 2 si 0x8041adfc 186 94812 1000 1576/6144 0 Statuspoll6 4 si 0x8041adfc 472 297 0 244/6144 0 SWPoll64bCnt7 2 si 0x8041adfc 92 3553068 1000 904/6144 0 SL_TASK8 2 si 0x8041adfc 113 142157 106000 1172/6144 0 RedundantTaskConsole> (enable)
Table 2-56 describes the possible fields in the show proc command outputs.
| Field | Definition |
|---|---|
CPU Utilization | Sum of all the loads from all the processes running on the CPU in the last 5 seconds, 1 minute, and 5 minutes. |
PID | Process ID. |
Runtime | Time the process has run since getting created (in milliseconds). |
Invoked | Number of times the process was invoked since getting created. |
uSecs | Maximum time a process ran in a single invocation. |
5sec | Percentage of time this process ran on the CPU in the last 5 second interval. |
1Min | Percentage of time this process ran on the CPU in the last 1 minute interval. |
5Min | Percentage of time this process ran on the CPU in the last 5 minute interval. |
TTY | TTY associated with the process. |
Process | Name of the process. |
Allocated | Sum of all the memory malloced by the process since it was created, and includes the memory previously freed. |
Freed | Sum of memory the process has freed until now. |
Holding | Amount of memory the process is currently holding. |
PC | Calling PC for "show_process" function. |
Q | Process priority in terms of numbers. Low number means high priority. |
T | State of the process (Running, we=waiting for event, st=sleeping, si=sleeping on an interval, rd=ready to run, id=idle, xx=dead/zombie). |
Stacks | Size of the stack used by the process or the total stack size allocated to the process (in bytes). |
Use the show protocolfilter command to list whether protocol filtering is enabled or disabled.
show protocolfilterThis command has no keywords or arguments.
This command has no default setting.
Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch
Catalyst 2980G switch
Switch command.
Normal.
This command is not supported by the three-port Gigabit Ethernet switching module (WS-X5403).
This example shows how to display whether protocol filtering is enabled or disabled:
Console> show protocolfilter Protocol filtering is enabled on this switch. Console>
Use the show qos info command to display QoS-related information for a specified port.
show qos info {runtime | config}
runtime | Keyword that specifies to show the current QoS run time information. |
config | Keyword that specifies to show the NVRAM setting of QoS. |
mod_num /port_num | Number of the module and the port. |
port_type | QoS port type. Valid port type is 1q4t. |
tx | Keyword that specifies to specify the transmit drop threshold. |
This command has no default setting.
Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2948G switch
Catalyst 2980G switch
Switch command.
Normal.
On the Catalyst 5000 family switches, this command is supported only with Supervisor Engine II G or III G, or Supervisor Engine III or III F with the NFFC II.
The mod_num /port_num argument, the port_type argument, and the tx keyword are not supported on the Catalyst 4000 family and 2948G switches.
The show qos info runtime command display shows both the absolute values and the percentages you specified for the drop thresholds, queue sizes, and WRR. However, the absolute values may not exactly match the percentages specified because of the precision limitations of the hardware.
On the Catalyst 5000 family switches, the transmit drop threshold percentages specified select a buffer usage level where each threshold applies. The percentages to buffer usage level shown below are approximate values that depend on the packet buffer size, which depends on the ASIC type.
The number preceding the t in the port-type determines the number of threshold values that the hardware supports. For example, with 1q4t, four thresholds are specified. The number preceding the q in the port-type determines the number of the queues that the hardware supports. For example, with 1q4t, one queue is specified.
This example shows how to display QoS-related NVRAM transmit threshold information (Catalyst 5000 family switches):
Console> (enable) show qos info config 1q4t tx QoS setting in NVRAM for 1q4t transmit: QoS is enabled Queue and Threshold Mapping: Queue Threshold CoS ----- --------- --------------- 1 1 0 1 1 2 2 3 1 3 4 5 1 4 6 7 Tx WRED thresholds: Queue # Thresholds in percentage ( in abs values ) ------- ------------------------------------------ 1 14% 28% 57% 100% Console>
This example shows how to display the current QoS runtime information for a port (Catalyst 5000 family switches):
Console>show qos info runtime 8/1Run time setting of QoS:QoS is enabledPort 8/1 has 1 transmit queue with 4 drop thresholds (1q4t).Default CoS = 0Queue and Threshold Mapping:Queue Threshold CoS----- --------- ---------------1 1 0 11 2 2 31 3 4 51 4 6 7Tx WRED thresholds:Queue # Thresholds in percentage ( in abs values )------- ------------------------------------------1 14% (16380 bytes) 28% (32764 bytes) 57% (65532 bytes) 100% (131068 bytes)Console>
This example shows how to display the current QoS configuration information for the switch (Catalyst 4000 family and 2948G switches):
Console> show qos info config QoS setting in NVRAM: QoS is enabled All ports have 2 transmit queues with 1 drop thresholds (2q1t). Default CoS = 4 Queue and Threshold Mapping: Queue Threshold CoS ----- --------- --------------- 1 1 0 1 2 3 2 1 4 5 6 7 Console>
set qos
set qos ip-filter
set qos mac-cos
set qos map
set qos router-mac
set qos wred-threshold
Use the show qos ip command to display the access control list.
show qos ip [runtime]
runtime | (Optional) Keyword that displays the runtime configuration verses the user configured configuration. |
This command has no default setting.
Catalyst 5000 family switches
Switch command.
Normal.
The runtime and user configured settings are different only if the QoS runtime policy source for the switch is COPS.
This command is supported only on Catalyst 5000 family switches with Supervisor Engine II G or III G, or Supervisor Engine III or III F with the NFFC II.
This example shows how to display the access control list and its details when COPS is disabled:
Console> (enable) show qos ip runtime
There are 1 IP filter(s).
ACE# Src IP and Mask Dest IP and Mask
---- -------------------------------- --------------------------------
1 171.33.22.7 0.0.0.255 172.22.33.5 0.0.255.255
Protocol Src Port Dst Port CoS Action
-------- -------- -------- --- ------
any 0 0 3 -
Console> (enable)
This example shows how to display the access control list and its details when COPS is enabled:
Console> (enable) show qos ip runtime
ACL# ACE# Src IP and Mask Dest IP and Mask
---- ---- -------------------------------- --------------------------------
1 1 1.2.3.4 0.0.255.255 host 5.6.7.8
Protocol Src Port Range Dst Port Range CoS Action
-------- -------------- -------------- --- ------
any 0 - 65535 0 - 65535 4 permit
1 2 any any
Protocol Src Port Range Dst Port Range CoS Action
-------- -------------- -------------- --- ------
any 0 - 65535 0 - 65535 4 deny
ACL# ACE# Src IP and Mask Dest IP and Mask
---- ---- -------------------------------- --------------------------------
2 1 1.2.3.4 0.0.255.255 host 5.6.7.8
Protocol Src Port Range Dst Port Range CoS Action
-------- -------------- -------------- --- ------
any 0 - 65535 0 - 65535 0 permit
Console> (enable)
set qos ip-filter
clear qos ip-filter
Use the show qos mac-cos command to display the currently configured QoS-related information for the MAC address and VLAN pair.
show qos mac-cos dest_mac [vlan]
dest_mac | MAC address of the destination host. |
vlan | (Optional) Number of the VLAN; valid values are 1 to 1005. |
all | Keyword that specifies all MAC address and VLAN pairs. |
This command has no default setting.
Catalyst 5000 family switches
Switch command.
Normal.
This command is supported only on Catalyst 5000 family switches with Supervisor Engine II G or III G, or Supervisor Engine III or III F with the NFFC II.
You can enter the show qos mac-cos command to display the currently configured QoS-related information. You can enter the show qos info config to view the NVRAM setting of QoS. This command might be useful to check if the NVRAM setting is different from the hardware setting. For example, if you configure some settings for QoS while QoS is disabled, the setting is saved in NVRAM but the hardware is operating with a different set of parameters.
This example shows how to display currently configured QoS-related information for all MAC address and VLAN pairs:
Console> (enable)show qos mac-cos allVLAN Dest MAC CoS---- ------------------ ---1 01-02-03-04-05-06 29 04-05-06-07-08-09 3Console> (enable)
This example shows how to display currently configured QoS-related information for a specific MAC address:
Console> (enable)show qos mac-cos 01-02-03-04-05-06VLAN Dest MAC CoS---- ------------------ ---1 01-02-03-04-05-06 2Console> (enable)
set qos mac-cos
clear qos mac-cos
Use the show qos policy-source command to display the QoS policy source information.
show qos policy-sourceThis command has no arguments or keywords.
This command has no default settings.
Catalyst 5000 family switches
Switch command.
Normal.
This command displays whether the QoS policy source is set to local or COPS.
This example shows how to view the QoS policy source:
Console> show qos policy-source QoS policy source for the switch set to local. QoS runtime policy source for the switch is local. Console>
Use the show qos router-mac command to display QoS router information for the MAC address and VLAN pair.
show qos router-mac [mac_addr | vlan]
mac_addr | (Optional) MAC address of the router. |
vlan | (Optional) Number of the VLAN; valid values are 1 to 1005. |
This command has no default setting.
Catalyst 5000 family switches
Switch command.
Normal.
This command is supported only on Catalyst 5000 family switches with Supervisor Engine II G or III G, or Supervisor Engine III or III F with the NFFC II.
The Number column displays a number indicating the order in which the entries were configured. This number has no functional significance to the entry.
This example shows how to display QoS router information for all MAC address and VLAN pairs:
Console> (enable) show qos router-mac
Number MAC address Vlan #
---------------------------------
1 00-40-0b-30-03-48 2
2 00-40-0b-30-03-48 3
Console> (enable)
This example shows how to display QoS router information for a specific MAC address:
Console> (enable)show qos router-mac 00-40-0b-30-03-48 Number MAC address Vlan # --------------------------------- 1 00-40-0b-30-03-48 2 2 00-40-0b-30-03-48 3Console> (enable)
set qos router-mac
clear qos router-mac
Use the show qos statistics command to display QoS-related counters for a specified module.
show qos statistics {mod_num[/port_num]}
mod_num | Number of the module. |
/port_num | (Optional) Number of the port. |
This command has no default setting.
Catalyst 5000 family switches
Switch command.
Normal.
This command is supported only on Catalyst 5000 family switches with Supervisor Engine II G or III G, or Supervisor Engine III or III F with the NFFC II.
In the output, the Threshold #:Packets dropped field lists each threshold and the number of packets dropped. For example, 1:0 pkt, 2:0 pkts indicates that thresholds 1 and 2 had 0 packets dropped.
This example shows how to display QoS statistics information for module 2, port 1:
Console> (enable) show qos statistics 2/1On Transmit: Port 2/1 has 2 Queue(s) 2 Threshold(s)Q # Threshold #:Packets dropped--- -----------------------------------------------1 1:0 pkts , 2:0 pkts2 1:0 pkts , 2:0 pktsOn Receive: Port 2/1 has 1 Queue(s) 4 Threshold(s)Rx drop threshold counters are disabled for untrusted ports.Q # Threshold #:Packets dropped--- -----------------------------------------------1 1:0 pkts, 2:0 pkts, 3:0 pkts, 4:0 pktsConsole> (enable)
set qos
set qos ip-filter
set qos mac-cos
set qos map
set qos router-mac
set qos wred-threshold
Use the show radius command to display configured RADIUS parameters.
show radius [noalias]
noalias | (Optional) Keyword that forces the display to show IP addresses, not IP aliases. |
This command has no default setting.
Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch
Catalyst 2980G switch
Switch command.
Normal.
This command can be entered in Normal or Privileged mode, but the RADIUS key is displayed only if this command is entered in Privileged mode.
This example shows how to display RADIUS information:
Console> (enable) show radius Login Authentication: Console Session Telnet Session --------------------- ---------------- --------------- tacacs disabled disabled radius enabled(primary) enabled(primary) local enabled enabled Enable Authentication: Console Session Telnet Session ---------------------- ---------------- --------------- tacacs disabled disabled radius enabled(primary) enabled(primary) local enabled enabled Radius deadtime: 0 minutes Radius key: hello Radius retransmit: 3 Radius timeout: 5 seconds Radius-Server Status Auth-port Acct-port ------------------- ------- --------- --------- 198.32.67.9 primary 1645 1813 172.31.11.12 1645 1646 Console> (enable)
set qos
set radius key
set radius retransmit
set radius server
set radius timeout
Use the show rgmp group command to display all multicast groups or the count of multicast groups that are joined by RGMP-capable routers.
show rgmp group [mac_addr] [vlan_id]
mac_addr | (Optional) MAC destination address reserved for the use of RGMP packets. |
vlan_id | (Optional) Number of the VLAN; valid values are from 1 to 1005. |
This command has no default setting.
Catalyst 5000 family switches
Switch command.
Normal.
This example displays all multicast groups joined by RGMP-capable routers:
Console> show rgmp group Vlan Dest MAC/Route Des RGMP Joined Router Ports --------------------------------------------------------------------- 1 01-00-5e-00-01-28 5/1,5/15 1 01-00-5e-01-01-01 5/1 2 01-00-5e-27-23-70* 3/1,5/1 Total Number of Entries=3 `*'- Configured manually
Console>
This example displays the total number of entries of VLAN group 1 that are joined by RGMP-capable routers:
Console> show rgmp group count 1 RGMP enabled. Total Number of Entries=2 Console>
set rgmp
show rgmp statistics
clear rgmp statistics
Use the show rgmp statistics command to display all the RGMP-related statistics for a given VLAN.
show rgmp statistics [vlan]
vlan | (Optional) Number of the VLAN. |
The default is VLAN 1.
Catalyst 5000 family switches
Switch command.
Normal.
This example displays RGMP-related statistics for a specific VLAN:
Console> show rgmp statistics 23 RGMP enabled RGMP Statistics for vlan <23>: Recieve:
Valid pkts: 20 Hellos: 10 Joins: 5 Leaves: 5 Join Alls: 0 Leave Alls: 0 Byes: 0 Discarded: 0 Transmit: Total Pkts: 10 Failures: 0 Hellos: 10 Joins: 0 Leaves: 0 Join Alls: 0 Leave Alls: 0 Byes: 0 Console>
Use the show rif command to display RIF information.
show rif [vlan_num]
vlan_num | (Optional) Number of the VLAN that you want to view RIF information. |
This command has no default setting.
Catalyst 5000 family switches
Switch command.
Normal.
This example shows how to display RIF information for the system and for a VLAN:
Console> show rifMAC VLAN RIF-------------------- -------- --------------------00:00:30:e2:cf:00 on 401 via 0610.001a.002000:05:77:01:bc:4a on 1020 via 0690.00d1.00e200:05:77:01:bc:4b on 1020 via 0690.00d1.00e200:05:77:01:bc:48 on 1020 via 0690.00d1.00e2
This example shows how to display RIF information for a VLAN:
Console>show rif 401MAC VLAN RIF-------------------- -------- --------------------00:00:30:e2:cf:00 on 401 via 0610.001a.0020Console>
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Tue Mar 21 09:15:18 PST 2000
Copyright 1989 - 2000©Cisco Systems Inc.