|
|
This chapter describes how to work with system software image files.
This chapter consists of these sections:
You can download system software images to the switch using the Trivial File Transfer Protocol (TFTP). TFTP allows you to download system image files over the network from a TFTP server.
Some modules, such as Catalyst 5000 family FDDI and ATM modules, have their own onboard Flash. When you download a software image file, the switch checks the header of the image file to determine the type of software image.
Depending on the type of software image you are downloading, one of the following occurs:
![]() | Caution Some supervisor engine software releases update the supervisor engine erasable programmable logic devices (EPLDs). The EPLDs can be updated only a limited number of times. You should avoid loading a new software release and then backing out unnecessarily. The supervisor engine software release notes indicate which software releases have code that updates the EPLDs. |
Before you begin downloading a software image using TFTP, make sure of the following:
Use the following procedure to download a supervisor engine software image to the switch from a TFTP server:
Step 1 Copy the software image file to the appropriate TFTP directory on the workstation.
Step 2 Log into the switch through the console port or through a Telnet session. If you log in using Telnet, your Telnet session disconnects when you reset the switch to run the new software.
Step 3 Use the command appropriate for your switch and supervisor engine to download the software image from the TFTP server:
The switch downloads the image file from the TFTP server:
Step 4 Catalyst 5000 family Supervisor Engine III and III F, and Catalyst 4000, 2926G series, and 2948G switches---Modify the BOOT environment variable using the set boot system flash device:filename prepend command, so that the new image boots when you reset the switch. Specify the Flash device (device:) and the filename of the downloaded image (filename).
Step 5 Reset the switch using the reset system command. If you are connected to the switch through Telnet, your Telnet session disconnects.
During startup, on the Catalyst 5000 family Supervisor Engine III and III F, and on the Catalyst 4000 family, 2926G series, and 2948G switches, the Flash memory on the supervisor engine is reprogrammed with the new Flash code.
Step 6 When the switch reboots, enter the show version command to check the version of the code on the switch.
Step 1 Copy the software image file to the appropriate TFTP directory on the workstation.
Step 2 Log into the switch through the console port or a Telnet session. If you log in using Telnet, your Telnet session might disconnect when you reset modules to run the new software.
Step 3 Use the command appropriate for your switch and supervisor engine to download the software image from the TFTP server:
The switch downloads the image file, erases the Flash memory on the appropriate modules, and reprograms the Flash memory with the downloaded Flash code.
Step 4 Reset the appropriate modules using the reset mod_num command. If you are connected through Telnet, your Telnet session disconnects if you reset the module through which your connection was made.
Step 5 When the upgraded modules come online, enter the show version [mod_num] command to check the version of the code on the switch.
These sections show example TFTP download procedures:
This example shows a complete TFTP download procedure of a supervisor engine software image to a Catalyst 5000 family switch with a Supervisor Engine III or III F module, or to a Catalyst 4000 family, 2926G series, or 2948G switch:
Console> (enable) show version 1
Mod Port Model Serial # Versions
--- ---- ---------- --------- ----------------------------------------
1 2 WS-X5530 007451586 Hw : 1.3
Fw : 3.1.2
Fw1: 3.1(2)
Sw : 4.1(2)
Console> (enable) copy tftp flash
IP address or name of remote host []? 172.20.52.3
Name of file to copy from []? cat5000-sup3.4-2-1.bin
Flash device [bootflash]?
Name of file to copy to [cat5000-sup3.4-2-1.bin]?
4369664 bytes available on device bootflash, proceed (y/n) [n]? y
CCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCC
CCCCCCCCCCCCCCCCCCC
File has been copied successfully.
Console> (enable) set boot system flash bootflash:cat5000-sup3.4-2-1.bin prepend
BOOT variable = bootflash:cat5000-sup3.4-2-1.bin,1;bootflash:cat5000-sup3.4-1
-2.bin,1;
Console> (enable) reset system
This command will reset the system.
Do you want to continue (y/n) [n]? y
Console> (enable) 07/21/1998,13:51:39:SYS-5:System reset from Console//
System Bootstrap, Version 3.1(2)
Copyright (c) 1994-1997 by cisco Systems, Inc.
Presto processor with 32768 Kbytes of main memory
Autoboot executing command: "boot bootflash:cat5000-sup3.4-2-1.bin"
CCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCC
CCCCCCCCCCCCCCCCCCC
Uncompressing file: ###########################################################
################################################################################
################################################################################
################################################################################
################################################################################
################################################################################
################################################################################
################################################################################
################################################################################
################################################################################
#############
System Power On Diagnostics
NVRAM Size .. .................512KB
ID Prom Test ..................Passed
DPRAM Size ....................16KB
DPRAM Data 0x55 Test ..........Passed
DPRAM Data 0xaa Test ..........Passed
DPRAM Address Test ............Passed
Clearing DPRAM ................Done
System DRAM Memory Size .......32MB
DRAM Data 0x55 Test ...........Passed
DRAM Data 0xaa Test ...........Passed
DRAM Address Test ............Passed
Clearing DRAM .................Done
EARL++ ........................Present
EARL RAM Test .................Passed
EARL Serial Prom Test .........Passed
Level2 Cache ..................Present
Level2 Cache test..............Passed
Boot image: bootflash:cat5000-sup3.4-2-1.bin
Downloading epld sram device please wait ...
Programming successful for Altera 10K10 SRAM EPLD
Downloading epld sram device please wait ...
Programming successful for Altera 10K30 SRAM EPLD
Downloading epld sram device please wait ...
Cisco Systems Console
Enter password:
07/21/1998,13:52:51:SYS-5:Module 1 is online
07/21/1998,13:53:11:SYS-5:Module 4 is online
07/21/1998,13:53:11:SYS-5:Module 5 is online
07/21/1998,13:53:14:PAGP-5:Port 1/1 joined bridge port 1/1.
07/21/1998,13:53:14:PAGP-5:Port 1/2 joined bridge port 1/2.
07/21/1998,13:53:40:SYS-5:Module 2 is online
07/21/1998,13:53:45:SYS-5:Module 3 is online
Console> show version 1
Mod Port Model Serial # Versions
--- ---- ---------- --------- ----------------------------------------
1 2 WS-X5530 007451586 Hw : 1.3
Fw : 3.1.2
Fw1: 3.1(2)
Sw : 4.2(1)
Console>
This example shows a complete TFTP download procedure of a supervisor engine software image to a Catalyst 5000 family switch with a Supervisor Engine II, II G, or III G module:
Console> (enable) show version 1
Mod Port Model Serial # Versions
--- ---- ---------- --------- ----------------------------------------
1 2 WS-X5509 007486003 Hw : 2.3
Fw : 3.1(2)
Fw1: 3.1(1)
Sw : 4.1(2)
Console> (enable) download 172.20.52.3 cat5000-supg.5-2-1.bin
Download image cat5000-supg.5-2-1.bin from 172.20.52.3 to module 1 FLASH
(y/n) [n]? y
/
Finished network single module download. (4104180 bytes)
Erasing flash sector...done.
Programming flash sector...done.
Verifying Flash Image ...
The system needs to be reset to run the new image.
Console> (enable) reset
This command will reset the system.
Do you want to continue (y/n) [n]? y
%SYS-5-SYS_RESET:System reset from Console//
Console> (enable)
ATE0
ATS0=1
ROM Power Up Diagnostics of Apr 20 1999
Init NVRAM Log
LED Test ................... done
ROM Checksum ............... passed
Dual Port RAM r/w Test ..... passed
ID PROM .................... passed
System DRAM Size(mb) ....... 32
DRAM Data Bus Test ......... passed
DRAM Address Test .......... passed
DRAM Byte/Word Access Test .. passed
BOOTROM Version 5.1(1), Dated Apr 20 1999 11:09:48
BOOT date: 09/01/99 BOOT time: 14:33:03
uncompressing nmp image
This will take a minute...
NMP image is successfully uncompressed in DRAM
Running System Diagnostics from this Supervisor (Module 1)
This may take up to 2 minutes....please wait
Cisco Systems Console
Enter password:
%MLS-5-MLSENABLED:IP Multilayer switching is enabled
%MLS-5-NDEDISABLED:Netflow Data Export disabled
%SYS-5-MOD_OK:Module 1 is online
%SYS-5-MOD_OK:Module 9 is online
%SYS-5-MOD_OK:Module 3 is online
%SYS-5-MOD_OK:Module 7 is online
%SYS-5-MOD_OK:Module 6 is online
Console> show version 1
Mod Port Model Serial # Versions
--- ---- ---------- --------- ----------------------------------------
1 2 WS-X5550 013490945 Hw : 1.1
Fw : 5.1(1)
Fw1: 5.1(1)
Sw : 5.2(1)
Console>
This example shows a complete TFTP download procedure of an ATM software image to a single ATM module in a Catalyst 5000 family switch with a Supervisor Engine III or III F module:
Console> (enable) show version 4
Mod Port Model Serial # Versions
--- ---- ---------- --------- ----------------------------------------
4 1 WS-X5155 003414855 Hw : 1.2
Fw : 1.3
Fw1: 1.3
Sw : 3.2(6)
Console> (enable) copy tftp 4/flash
IP address or name of remote host []? 172.20.52.3
Name of file to copy from []? cat5000-atm.3-2-7.bin
Download image tftp:cat5000-atm.3-2-7.bin to Module 4 FLASH (y/n) [n]? y
This command will reset Download Module(s) you selected.
Do you wish to continue download flash (y/n) [n]? y
-
Download done for module 4, please wait for it to come online
File has been copied successfully.
Console> (enable) 07/21/1998,13:13:54:SYS-5:Module 4 is online
Console> (enable) show version 4
Mod Port Model Serial # Versions
--- ---- ---------- --------- ----------------------------------------
4 1 WS-X5155 003414855 Hw : 1.2
Fw : 1.3
Fw1: 1.3
Sw : 3.2(7)
Console> (enable)
This example shows a complete TFTP download procedure of an FDDI software image to a single FDDI module in a Catalyst 5000 family switch with a Supervisor Engine II, II G, or III G module:
Console> (enable) show version 3
Mod Port Model Serial # Versions
--- ---- ---------- --------- ----------------------------------------
3 2 WS-X5101 003489788 Hw : 1.0
Fw : 1.1
Fw1: 1.3
Sw : 2.1(7)
Console> (enable) download 172.20.52.3 cat5000-fddi.3-1-1.bin 3
This command will reset module 3.
Download image cat5000-fddi.3-1-1.bin from 172.20.52.3 to Module 3 FLASH (y/n) [
n]? y
|
Finished network single module download. (1060456 bytes)
...............................................................................
...............................................................................
...............................................................................
...............................................................................
...............................................................................
..................................
SCP download checksum ok
SCP download done.
Please wait until module 3 comes online before resetting.
(Approximately 5 minutes)
Console> (enable) Console> (enable) 07/21/1998,11:23:36:SYS-5:Module 3 FLASH pro
gramming complete
07/21/1998,11:24:59:SYS-5:Module 3 is online
07/21/1998,11:25:00:DTP-5:Port 3/1-2 has become dot10 trunk
Console> (enable) show version 3
Mod Port Model Serial # Versions
--- ---- ---------- --------- ----------------------------------------
3 2 WS-X5101 003489788 Hw : 1.0
Fw : 1.1
Fw1: 1.3
Sw : 3.1(1)
Console> (enable)
This example shows a complete TFTP download procedure of an ATM software image to multiple ATM modules in a Catalyst 5000 family switch with a Supervisor Engine III or III F module:
Console> (enable) show version 4
Mod Port Model Serial # Versions
--- ---- ---------- --------- ----------------------------------------
4 1 WS-X5155 003414855 Hw : 1.2
Fw : 1.3
Fw1: 1.3
Sw : 3.2(6)
Console> (enable) show version 5
Mod Port Model Serial # Versions
--- ---- ---------- --------- ----------------------------------------
5 1 WS-X5155 003414463 Hw : 1.2
Fw : 1.3
Fw1: 1.3
Sw : 3.2(6)
Console> (enable) copy tftp flash
IP address or name of remote host []? 172.20.52.3
Name of file to copy from []? cat5000-atm.3-2-7.bin
Download image tftp:cat5000-atm.3-2-7.bin to Module 4 FLASH (y/n) [n]? y
Download image tftp:cat5000-atm.3-2-7.bin to Module 5 FLASH (y/n) [n]? y
This command will reset Download Module(s) you selected.
Do you wish to continue download flash (y/n) [n]? y
-
Download done for module 4, please wait for it to come online
Download done for module 5, please wait for it to come online
File has been copied successfully.
Console> (enable) 07/21/1998,12:25:10:SYS-5:Module 4 is online
07/21/1998,12:25:10:SYS-5:Module 5 is online
Console> (enable) show version 4
Mod Port Model Serial # Versions
--- ---- ---------- --------- ----------------------------------------
4 1 WS-X5155 003414855 Hw : 1.2
Fw : 1.3
Fw1: 1.3
Sw : 3.2(7)
Console> (enable) show version 5
Mod Port Model Serial # Versions
--- ---- ---------- --------- ----------------------------------------
5 1 WS-X5155 003414463 Hw : 1.2
Fw : 1.3
Fw1: 1.3
Sw : 3.2(7)
Console> (enable)
This example shows a complete TFTP download procedure of an ATM software image to multiple ATM modules in a Catalyst 5000 family switch with a Supervisor Engine II, II G, or III G module:
Console> (enable) show version 8
Mod Port Model Serial # Versions
--- ---- ---------- --------- ----------------------------------------
8 1 WS-X5155 003414855 Hw : 1.2
Fw : 1.3
Fw1: 1.3
Sw : 3.2(4)
Console> (enable) show version 9
Mod Port Model Serial # Versions
--- ---- ---------- --------- ----------------------------------------
9 1 WS-X5155 003414463 Hw : 1.2
Fw : 1.3
Fw1: 1.3
Sw : 3.2(6)
Console> (enable) download 172.20.52.3 cat5000-atm.3-2-7.bin
Download image cat5000-atm.3-2-7.bin from 172.20.52.3 to Module 8 FLASH (y/n) [n
]? y
Download image cat5000-atm.3-2-7.bin from 172.20.52.3 to Module 9 FLASH (y/n) [n
]? y
This command will reset download module(s) you selected.
Do you wish to continue download to flash (y/n) [n]? y
-
Download done for module 8, please wait for it to come online
Download done for module 9, please wait for it to come online
Finished network multiple modules download. (2378316 bytes)
Please wait until module(s) come online before resetting.
Console> (enable) 07/21/1998,13:19:54:SYS-5:Module 8 is online
07/21/1998,13:19:54:SYS-5:Module 9 is online
Console> (enable) show version 8
Mod Port Model Serial # Versions
--- ---- ---------- --------- ----------------------------------------
8 1 WS-X5155 003414855 Hw : 1.2
Fw : 1.3
Fw1: 1.3
Sw : 3.2(7)
Console> (enable) show version 9
Mod Port Model Serial # Versions
--- ---- ---------- --------- ----------------------------------------
9 1 WS-X5155 003414463 Hw : 1.2
Fw : 1.3
Fw1: 1.3
Sw : 3.2(7)
Console> (enable)
These sections describe how to upload system software images from a switch to a TFTP server:
Before you attempt to upload a software image to a TFTP server, do the following:
Use this procedure to upload a software image on a switch to a TFTP server for storage:
Step 1 Log into the switch through the console port or a Telnet session.
Step 2 Upload the software image to the TFTP server using the command appropriate for your switch and supervisor engine:
The software image is uploaded to the TFTP server.
This example shows how to upload the supervisor engine software image on a Catalyst 5000 family Supervisor Engine III to a TFTP server:
Console> (enable) copy flash tftp Flash device [bootflash]? slot0: Name of file to copy from []? cat5000-sup3.5-1-1.bin IP address or name of remote host [172.20.52.3]? 172.20.52.10 Name of file to copy to [cat5000-sup3.5-1-1.bin]? CCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCC CCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCC| File has been copied successfully. Console> (enable)
This example shows how to upload the supervisor engine software image on a Catalyst5000 family Supervisor EngineII to a TFTP server:
Console> (enable) upload 172.20.52.3 cat5000-sup.4-2-1.bin Upload Module 1 image to cat5000-sup.4-2-1.bin on 172.20.52.3 (y/n) [n]? y - Finished network upload. (3021332 bytes) Console> (enable)
You can download system software images to the switch using the remote copy protocol (rcp); rcp allows you to download system image files over the network from an rcp server.
Some modules, such as Catalyst 5000 family FDDI and ATM modules, have their own onboard Flash. When you download a software image file, the switch checks the header of the image file to determine the type of software image.
Depending on the type of software image you are downloading, one of the following occurs:
![]() | Caution Some supervisor engine software releases update the supervisor engine erasable programmable logic devices (EPLDs). The EPLDs can be updated only a limited number of times. You should avoid loading a new software release and then backing out unnecessarily. The supervisor engine software release notes indicate which software releases have code that updates the EPLDs. |
Before you begin downloading a software image using rcp, make sure of the following:
Use the following procedure to download a supervisor engine software image to the switch from an rcp server:
Step 1 Copy the software image file to the appropriate rcp directory on the workstation.
Step 2 Log into the switch through the console port or through a Telnet session. If you log in using Telnet, your Telnet session disconnects when you reset the switch to run the new software.
Step 3 Use the command appropriate for your switch and supervisor engine to download the software image from the rcp server:
The switch downloads the image file from the rcp server:
Step 4 Catalyst 5000 family Supervisor Engine III and III F, and Catalyst 4000, 2926G series, and 2948G switches---Modify the BOOT environment variable using the set boot system flash device:filename prepend command, so that the new image boots when you reset the switch. Specify the Flash device (device:) and the filename of the downloaded image (filename).
Step 5 Reset the switch using the reset system command. If you are connected to the switch through Telnet, your Telnet session disconnects.
During startup, on the Catalyst 5000 family Supervisor Engine III and III F, and on the Catalyst 4000 family, 2926G series, and 2948G switches, the Flash memory on the supervisor engine is reprogrammed with the new Flash code.
Step 6 When the switch reboots, enter the show version command to check the version of the code on the switch.
Step 1 Copy the software image file to the appropriate rcp directory on the workstation.
Step 2 Log into the switch through the console port or a Telnet session. If you log in using Telnet, your Telnet session might disconnect when you reset modules to run the new software.
Step 3 Use the command appropriate for your switch and supervisor engine to download the software image from the rcp server:
The switch downloads the image file, erases the Flash memory on the appropriate modules, and reprograms the Flash memory with the downloaded Flash code.
Step 4 Reset the appropriate modules using the reset mod_num command. If you are connected through Telnet, your Telnet session disconnects if you reset the module through which your connection was made.
Step 5 When the upgraded modules come online, enter the show version [mod_num] command to check the version of the code on the switch.
These sections show example rcp download procedures:
This example shows a complete rcp download procedure of a supervisor engine software image to a Catalyst 5000 family switch with a Supervisor Engine III or III F module, or to a Catalyst 4000 family, 2926G series, or 2948G switch:
Console> (enable) show version 1
Mod Port Model Serial # Versions
--- ---- ---------- --------- ----------------------------------------
1 2 WS-X5530 007451586 Hw : 1.3
Fw : 3.1.2
Fw1: 3.1(2)
Sw : 4.1(2)
Console> (enable) copy rcp flash
IP address or name of remote host []? 172.20.52.3
Name of file to copy from []? cat5000-sup3.4-2-1.bin
Flash device [bootflash]?
Name of file to copy to [cat5000-sup3.4-2-1.bin]?
4369664 bytes available on device bootflash, proceed (y/n) [n]? y
CCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCC
CCCCCCCCCCCCCCCCCCC
File has been copied successfully.
Console> (enable) set boot system flash bootflash:cat5000-sup3.4-2-1.bin prepend
BOOT variable = bootflash:cat5000-sup3.4-2-1.bin,1;bootflash:cat5000-sup3.4-1
-2.bin,1;
Console> (enable) reset system
This command will reset the system.
Do you want to continue (y/n) [n]? y
Console> (enable) 07/21/1998,13:51:39:SYS-5:System reset from Console//
System Bootstrap, Version 3.1(2)
Copyright (c) 1994-1997 by cisco Systems, Inc.
Presto processor with 32768 Kbytes of main memory
Autoboot executing command: "boot bootflash:cat5000-sup3.4-2-1.bin"
CCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCC
CCCCCCCCCCCCCCCCCCC
Uncompressing file: ###########################################################
################################################################################
################################################################################
################################################################################
################################################################################
################################################################################
################################################################################
################################################################################
################################################################################
################################################################################
#############
System Power On Diagnostics
NVRAM Size .. .................512KB
ID Prom Test ..................Passed
DPRAM Size ....................16KB
DPRAM Data 0x55 Test ..........Passed
DPRAM Data 0xaa Test ..........Passed
DPRAM Address Test ............Passed
Clearing DPRAM ................Done
System DRAM Memory Size .......32MB
DRAM Data 0x55 Test ...........Passed
DRAM Data 0xaa Test ...........Passed
DRAM Address Test ............Passed
Clearing DRAM .................Done
EARL++ ........................Present
EARL RAM Test .................Passed
EARL Serial Prom Test .........Passed
Level2 Cache ..................Present
Level2 Cache test..............Passed
Boot image: bootflash:cat5000-sup3.4-2-1.bin
Downloading epld sram device please wait ...
Programming successful for Altera 10K10 SRAM EPLD
Downloading epld sram device please wait ...
Programming successful for Altera 10K30 SRAM EPLD
Downloading epld sram device please wait ...
Cisco Systems Console
Enter password:
07/21/1998,13:52:51:SYS-5:Module 1 is online
07/21/1998,13:53:11:SYS-5:Module 4 is online
07/21/1998,13:53:11:SYS-5:Module 5 is online
07/21/1998,13:53:14:PAGP-5:Port 1/1 joined bridge port 1/1.
07/21/1998,13:53:14:PAGP-5:Port 1/2 joined bridge port 1/2.
07/21/1998,13:53:40:SYS-5:Module 2 is online
07/21/1998,13:53:45:SYS-5:Module 3 is online
Console> show version 1
Mod Port Model Serial # Versions
--- ---- ---------- --------- ----------------------------------------
1 2 WS-X5530 007451586 Hw : 1.3
Fw : 3.1.2
Fw1: 3.1(2)
Sw : 4.2(1)
Console>
This example shows a complete rcp download procedure of a supervisor engine software image to a Catalyst 5000 family switch with a Supervisor Engine II, II G, or III G module:
Console> (enable) show version 1
Mod Port Model Serial # Versions
--- ---- ---------- --------- ----------------------------------------
1 2 WS-X5509 007486003 Hw : 2.3
Fw : 3.1(2)
Fw1: 3.1(1)
Sw : 4.1(2)
Console> (enable) download 172.20.52.3 cat5000-sup.4-2-1.bin rcp
Download image cat5000-sup.4-2-1.bin from 172.20.52.3 to module 1 FLASH (y/n)
[n]? y
/
Finished network single module download. (2748504 bytes)
FLASH on Catalyst:
Type Address Location
Intel 28F016 20000000 NMP (P3) 8MB SIM
Erasing flash sector...done.
Programming flash sector...done.
Erasing flash sector...done.
Programming flash sector...done.
Erasing flash sector...done.
Programming flash sector...done.
The system needs to be reset to run the new image.
Console> (enable) reset system
This command will reset the system.
Do you want to continue (y/n) [n]? y
Console> (enable) 07/21/1998,10:52:36:SYS-5:System reset from Console//
ATE0
ATS0=1
ROM Power Up Diagnostics of Feb 19 1998
Init NVRAM Log
LED Test ................... done
ROM Checksum ............... passed
Dual Port RAM r/w Test ..... passed
ID PROM .................... passed
System DRAM Size(mb) ....... 16
DRAM Data Bus Test ......... passed
DRAM Address Test .......... passed
DRAM Byte/Word Access Test .. passed
EARL Test .................. passed
BOOTROM Version 3.1(2), Dated Feb 19 1998 11:05:50
BOOT date: 07/21/98 BOOT time: 10:52:51
Uncompressing NMP image. This will take a minute...
Downloading epld sram device please wait ...
Programming successful for Altera 10K10 SRAM EPLD
Updating epld flash version from 0000 to 0400
Running System Diagnostics from this Supervisor (Module 1)
This may take up to 2 minutes....please wait
Cisco Systems Console
Enter password:
07/21/1998,10:53:39:SYS-5:Module 1 is online
07/21/1998,10:53:58:PAGP-5:Port 1/1 joined bridge port 1/1.
07/21/1998,10:54:15:SYS-5:Module 7 is online
07/21/1998,10:54:22:SYS-5:Module 2 is online
07/21/1998,10:54:39:SYS-5:Module 9 is online
07/21/1998,10:54:43:SYS-5:Module 5 is online
07/21/1998,10:54:56:SYS-5:Module 3 is online
07/21/1998,10:54:57:SYS-5:Module 6 is online
07/21/1998,10:54:58:DTP-5:Port 3/1-2 has become dot10 trunk
07/21/1998,10:55:36:SYS-5:Module 2 is online
Console> show version 1
Mod Port Model Serial # Versions
--- ---- ---------- --------- ----------------------------------------
1 2 WS-X5509 007486003 Hw : 2.3
Fw : 3.1(2)
Fw1: 3.1(1)
Sw : 4.2(1)
Console>
This example shows a complete rcp download procedure of an ATM software image to a single ATM module in a Catalyst 5000 family switch with a Supervisor Engine III or III F module:
Console> (enable) show version 4
Mod Port Model Serial # Versions
--- ---- ---------- --------- ----------------------------------------
4 1 WS-X5155 003414855 Hw : 1.2
Fw : 1.3
Fw1: 1.3
Sw : 3.2(6)
Console> (enable) copy rcp 4/flash
IP address or name of remote host []? 172.20.52.3
Name of file to copy from []? cat5000-atm.3-2-7.bin
Download image rcp:cat5000-atm.3-2-7.bin to Module 4 FLASH (y/n) [n]? y
This command will reset Download Module(s) you selected.
Do you wish to continue download flash (y/n) [n]? y
-
Download done for module 4, please wait for it to come online
File has been copied successfully.
Console> (enable) 07/21/1998,13:13:54:SYS-5:Module 4 is online
Console> (enable) show version 4
Mod Port Model Serial # Versions
--- ---- ---------- --------- ----------------------------------------
4 1 WS-X5155 003414855 Hw : 1.2
Fw : 1.3
Fw1: 1.3
Sw : 3.2(7)
Console> (enable)
This example shows a complete rcp download procedure of an FDDI software image to a single FDDI module in a Catalyst 5000 family switch with a Supervisor Engine II, II G, or III G module:
Console> (enable) show version 3
Mod Port Model Serial # Versions
--- ---- ---------- --------- ----------------------------------------
3 2 WS-X5101 003489788 Hw : 1.0
Fw : 1.1
Fw1: 1.3
Sw : 2.1(7)
Console> (enable) download 172.20.52.3 cat5000-fddi.3-1-1.bin 3 rcp
This command will reset module 3.
Download image cat5000-fddi.3-1-1.bin from 172.20.52.3 to Module 3 FLASH (y/n) [
n]? y
|
Finished network single module download. (1060456 bytes)
...............................................................................
...............................................................................
...............................................................................
...............................................................................
...............................................................................
..................................
SCP download checksum ok
SCP download done.
Please wait until module 3 comes online before resetting.
(Approximately 5 minutes)
Console> (enable) Console> (enable) 07/21/1998,11:23:36:SYS-5:Module 3 FLASH pro
gramming complete
07/21/1998,11:24:59:SYS-5:Module 3 is online
07/21/1998,11:25:00:DTP-5:Port 3/1-2 has become dot10 trunk
Console> (enable) show version 3
Mod Port Model Serial # Versions
--- ---- ---------- --------- ----------------------------------------
3 2 WS-X5101 003489788 Hw : 1.0
Fw : 1.1
Fw1: 1.3
Sw : 3.1(1)
Console> (enable)
This example shows a complete rcp download procedure of an ATM software image to multiple ATM modules in a Catalyst 5000 family switch with a Supervisor Engine III or III F module:
Console> (enable) show version 4
Mod Port Model Serial # Versions
--- ---- ---------- --------- ----------------------------------------
4 1 WS-X5155 003414855 Hw : 1.2
Fw : 1.3
Fw1: 1.3
Sw : 3.2(6)
Console> (enable) show version 5
Mod Port Model Serial # Versions
--- ---- ---------- --------- ----------------------------------------
5 1 WS-X5155 003414463 Hw : 1.2
Fw : 1.3
Fw1: 1.3
Sw : 3.2(6)
Console> (enable) copy rcp flash
IP address or name of remote host []? 172.20.52.3
Name of file to copy from []? cat5000-atm.3-2-7.bin
Download image rcp:cat5000-atm.3-2-7.bin to Module 4 FLASH (y/n) [n]? y
Download image rcp:cat5000-atm.3-2-7.bin to Module 5 FLASH (y/n) [n]? y
This command will reset Download Module(s) you selected.
Do you wish to continue download flash (y/n) [n]? y
-
Download done for module 4, please wait for it to come online
Download done for module 5, please wait for it to come online
File has been copied successfully.
Console> (enable) 07/21/1998,12:25:10:SYS-5:Module 4 is online
07/21/1998,12:25:10:SYS-5:Module 5 is online
Console> (enable) show version 4
Mod Port Model Serial # Versions
--- ---- ---------- --------- ----------------------------------------
4 1 WS-X5155 003414855 Hw : 1.2
Fw : 1.3
Fw1: 1.3
Sw : 3.2(7)
Console> (enable) show version 5
Mod Port Model Serial # Versions
--- ---- ---------- --------- ----------------------------------------
5 1 WS-X5155 003414463 Hw : 1.2
Fw : 1.3
Fw1: 1.3
Sw : 3.2(7)
Console> (enable)
This example shows a complete rcp download procedure of an ATM software image to multiple ATM modules in a Catalyst 5000 family switch with a Supervisor Engine II, II G, or III G module:
Console> (enable) show version 8
Mod Port Model Serial # Versions
--- ---- ---------- --------- ----------------------------------------
8 1 WS-X5155 003414855 Hw : 1.2
Fw : 1.3
Fw1: 1.3
Sw : 3.2(4)
Console> (enable) show version 9
Mod Port Model Serial # Versions
--- ---- ---------- --------- ----------------------------------------
9 1 WS-X5155 003414463 Hw : 1.2
Fw : 1.3
Fw1: 1.3
Sw : 3.2(6)
Console> (enable) download 172.20.52.3 cat5000-atm.3-2-7.bin rcp
Download image cat5000-atm.3-2-7.bin from 172.20.52.3 to Module 8 FLASH (y/n) [n
]? y
Download image cat5000-atm.3-2-7.bin from 172.20.52.3 to Module 9 FLASH (y/n) [n
]? y
This command will reset download module(s) you selected.
Do you wish to continue download to flash (y/n) [n]? y
-
Download done for module 8, please wait for it to come online
Download done for module 9, please wait for it to come online
Finished network multiple modules download. (2378316 bytes)
Please wait until module(s) come online before resetting.
Console> (enable) 07/21/1998,13:19:54:SYS-5:Module 8 is online
07/21/1998,13:19:54:SYS-5:Module 9 is online
Console> (enable) show version 8
Mod Port Model Serial # Versions
--- ---- ---------- --------- ----------------------------------------
8 1 WS-X5155 003414855 Hw : 1.2
Fw : 1.3
Fw1: 1.3
Sw : 3.2(7)
Console> (enable) show version 9
Mod Port Model Serial # Versions
--- ---- ---------- --------- ----------------------------------------
9 1 WS-X5155 003414463 Hw : 1.2
Fw : 1.3
Fw1: 1.3
Sw : 3.2(7)
Console> (enable)
These sections describe how to upload system software images from a switch to an rcp server:
Before you attempt to upload a software image to an rcp server, do the following:
Use this procedure to upload a software image on a switch to an rcp server for storage:
Step 1 Log into the switch through the console port or a Telnet session.
Step 2 Upload the software image to the rcp server using the command appropriate for your switch and supervisor engine:
The software image is uploaded to the rcp server.
This example shows how to upload the supervisor engine software image on a Catalyst 5000 family Supervisor Engine III to an rcp server:
Console> (enable) copy flash rcp Flash device [bootflash]? slot0: Name of file to copy from []? cat5000-sup3.5-1-1.bin IP address or name of remote host [172.20.52.3]? 172.20.52.10 Name of file to copy to [cat5000-sup3.5-1-1.bin]? CCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCC CCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCC| File has been copied successfully. Console> (enable)
This example shows how to upload the supervisor engine software image on a Catalyst5000 family Supervisor EngineII to an rcp server:
Console> (enable) upload 172.20.52.3 cat5000-sup.4-2-1.bin rcp Upload Module 1 image to cat5000-sup.4-2-1.bin on 172.20.52.3 (y/n) [n]? y - Finished network upload. (3021332 bytes) Console> (enable)
These sections describe how to perform a serial download of software images over the supervisor engine console port using Kermit, a common file-transfer and terminal-emulation software program:
Before you begin a serial download of a software image using Kermit, make sure of the following:
| Caution To prevent communication problems, do not use a speed greater than 19,200 baud. |
Use this procedure to perform a serial download of a software image over the supervisor engine console port:
Step 1 Copy the software image file to the directory where Kermit is loaded.
Step 2 Start Kermit on the PC.
Step 3 At the Kermit> prompt, enter the connect command to connect to the switch. If your line and speed are set correctly, the switch Console> prompt appears.
Step 4 Enter the enable command to enter privileged mode.
Step 5 Enter the download serial command. The file is downloaded to module 1 by default.
Step 6 When prompted, confirm the download.
Step 7 Enter the escape sequence Ctrl-]-c by holding down the Ctrl key while you press ], and then press c.
Step 8 At the Kermit> prompt, enter the send filename command to send the file to the switch.
The switch downloads the image file, erases the Flash memory on the supervisor engine or the appropriate module, and reprograms the Flash memory with the downloaded Flash code.
Step 9 When the Kermit> prompt reappears, enter the connect command to return to the switch Console> prompt. You will see status information as the switch erases and reprograms the Flash memory.
Step 10 Reset the switch using the reset system command.
Step 11 When the switch reboots, enter the show version [mod_num] command to check the version of the code on the switch.
Use this procedure to perform a serial download of a software image over the supervisor engine console port.
To copy the software to the workstation, log in as root, and perform these steps:
Step 1 Copy the software image file to your home directory.
Step 2 At the UNIX command prompt, start Kermit by entering the kermit command (make sure the directory where Kermit is installed is included in the $PATH environment variable on the workstation).
Step 3 At the C-Kermit> prompt, enter the connect command to connect to the switch. If your line and speed are set correctly, the switch Console> prompt appears.
Step 4 Enter the enable command to enter privileged mode.
Step 5 Enter the download serial command. The file downloads to module 1 by default.
Step 6 When prompted, confirm the download.
Step 7 Enter the escape sequence Ctrl-\-c by holding down the Ctrl key while you press \, and then press c.
Step 8 At the Kermit> prompt, enter the send filename command to send the file to the switch.
You can monitor the progress of the download by pressing the a key at any time during the Kermit download. A dot appears onscreen for every four packets transferred. If there is a problem transferring the file, one or more of the following letter codes appear:
The switch downloads the image file, erases the Flash memory on the supervisor engine or the appropriate module, and reprograms the Flash memory with the downloaded Flash code.
Step 9 Press Return to return to the C-Kermit> prompt. When the Kermit> prompt reappears, enter the connect command to return to the switch Console> prompt. You will see status information as the switch erases and reprograms the Flash memory.
Step 10 Reset the switch using the reset system command.
Step 11 When the switch reboots, enter the show version [mod_num] command to check the version of the code on the switch.
These sections show example serial download procedures over the supervisor engine console port using Kermit:
This screen output shows an example of a complete serial download procedure on a PC:
C:\ copy A:\*.* copying c5009_xx.bin C:\ kermit Kermit, 4C(057) 06 Apr 98, 4.2 BSD Type ? for help Kermit> set port com1 Kermit> set speed 9600 Kermit> connect Connecting to com1,speed 9600. The escape character is ^] (ASCII 29). Type the escape character followed by C to get back, or followed by ? to see other options Console> enable Console> (enable) download serial Download CBI image via console port (y/n) [n]? y Waiting for DOWNLOAD! Return to your local Machine by typing its escape sequence Issue Kermit send command from there[ Send \QFilename\Q] <CONTROL-] c to return to Local Machine> Kermit> send c5009_xx.bin File name: c5009_xx.bin KBytes transferred: xxxx Percent transferred: 100% Sending: Complete Number of Packets: xxxx Number of retries: None Last error: None Last warning: None Kermit> connect Finished network download. (1136844 bytes) Flash erase in progress ... Erase done Programming Flash: Flash Programming Complete Flash erase in progress ... Erase done Programming Flash: Flash Programming Complete Flash erase in progress ... Erase done Programming Flash: Flash Programming Complete Flash erase in progress ... Erase done Programming Flash: Flash Programming Complete Flash erase in progress ... Erase done Programming Flash: Flash Programming Complete Flash erase in progress ... Erase done Programming Flash: Flash Programming Complete Flash erase in progress ... Erase done Programming Flash: Flash Programming Complete The system needs to be reset to run the new image. Cisco Systems Console
Enter password:
Mon Apr 06, 1998, 14:35:08
Console>
This screen output shows an example of a complete serial download procedure on a UNIX workstation:
workstation% cd /tmp workstation% tar -xvfp /dev/rfd0 c5009_xx.bin, 1156046 bytes, 2258 tape blocks workstation% ls -la total 1150 drwxrwsrwt 5 bin 512 Sep 28 04:15 . drwxr-xr-x 18 root 1536 Sep 27 15:41 .. -r--r--r-- 1 60000 1156046 Jul 18 10:32 c5009_xx.bin workstation% kermit C-Kermit, 4E(072) 06 Apr 98, SUNOS 4.x Type ? for help C-Kermit> set line /dev/ttya C-Kermit> set speed 9600 /dev/ttya: 9600 baud C-Kermit> connect Connecting thru /dev/ttya, speed 9600. The escape character is CTRL-\ (28). Type the escape character followed by C to get back, or followed by ? to see other options. Console> enable Console> (enable) download serial c5009_xx.bin Download CBI image via console port (y/n) [n]? y Waiting for DOWNLOAD! Return to your local Machine by typing its escape sequence Issue Kermit send command from there[ Send \QFilename\Q] [Back at Local System] C-Kermit> send c5009_xx.bin SF c5009_xx.bin => c5009_xx.bin, Size: 1156046 CTRL-F to cancel file, CTRL-R to resend current packet CTRL-B to cancel batch, CTRL-A for status report: .............................................................................................................................. *** Display Truncated *** ............................................................... .................................... [OK] ZB? C-Kermit> connect Connecting thru /dev/ttya, speed 9600. The escape character is CTRL-\ (28). Type the escape character followed by C to get back, or followed by ? to see other options. Download OK Initializing Flash Programming Flash Base....Code....Length....Time....Done Cisco Systems Console Enter password: Mon Apr 06, 1998, 17:35:08 Console>
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Fri Oct 1 13:25:41 PDT 1999
Copyright 1989-1999©Cisco Systems Inc.