cc/td/doc/product/lan/cat5000/rel_5_2
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

show vtp domain
show vtp statistics
slip
squeeze
switch
sync
telnet
test snmp trap
traceroute
unalias
undelete
unset=varname
upload
varname=
verify
wait
write
write terminal

show vtp domain

Use the show vtp domain command to display VTP domain information.

show vtp domain

Syntax Description

This command has no keywords or arguments.

Default

This command has no default setting.

Supported Platforms

Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch

Command Type

Switch command.

Command Mode

Normal.

Example

This example shows how to display VTP domain information:

Console> show vtp domain
Domain Name                      Domain Index VTP Version Local Mode  Password
-------------------------------- ------------ ----------- ----------- ----------
                                 1            2           server      -
 
Vlan-count Max-vlan-storage Config Revision Notifications
---------- ---------------- --------------- -------------
15         1023             5               disabled
 
Last Updater    V2 Mode Pruning  PruneEligible on Vlans
--------------- ------- -------- -------------------------
172.20.44.30    enabled disabled 2-1000
Console> 
 

Table 2-76 describes the fields in the show vtp domain command output.


Table 2-76: show vtp domain Command Output Fields
Field Description

Domain Name

Name of the VTP domain.

Domain Index

Domain index number of the domain.

VTP Version

VTP version number.

Local Mode

VTP mode (server, client, or transparent).

Password

Password required or not.

Vlan-count

Total number of VLANs in the domain.

Max-vlan-storage

Maximum number of VLANs allowed on the device.

Config Revision

VTP revision number used to exchange VLAN information.

Notifications

Notifications to SNMP (enabled or disabled).

Last Updater

IP address through which VTP was last updated.

V2 Mode

Status on whether VTP V2 mode is enabled or disabled.

Pruning

Status on whether VTP pruning is enabled or disabled.

PruneEligible on Vlans

VLANs on which pruning is allowed.

Related Command

set vtp

show vtp statistics

Use the show vtp statistics command to display VTP statistics.

show vtp statistics

Syntax Description

This command has no keywords or arguments.

Default

This command has no default setting.

Supported Platforms

Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch

Command Type

Switch command.

Command Mode

Normal.

Example

This example shows how to display VTP statistics:

Console> show vtp statistics
VTP statistics:
summary advts received          0
subset  advts received          0
request advts received          0
summary advts transmitted       1
subset  advts transmitted       1
request advts transmitted       0
No of config revision errors    0
No of config digest errors      0
 
 
VTP pruning statistics:
 
Trunk     Join Transmitted  Join Received  Summary advts received from
                                          non-pruning-capable device
--------  ---------------  -------------  ---------------------------
 5/1-2
Console>
 

Table 2-77 describes the fields in the show vtp statistics command output.


Table 2-77: show vtp statistics Command Output Fields
Field Description

summary advts received

Total number of summary advt received.

subset advts received

Total number of subset advt received.

request advts received

Total number of request advts received.

summary advts transmitted

Total number of summary advts transmitted.

subset advts transmitted

Total number of subset advts transmitted.

request advts transmitted

Total number of request advts transmitted.

No of config revision errors

Number of config revision errors that have occurred.

No of config digest errors

Number of config revision digest errors that have occurred.

Trunk

Trunk port participating in VTP pruning.

Join Trasmitted

Number of VTP-Pruning Joins transmitted.

Join Received

Number of VTP-Pruning Joins received.

Summary advts received from nonpruning-capable device

Number of Summary advts received from nonpruning-capable devices.

Related Commands

set vtp
clear vtp statistics

slip

Use the slip command to attach or detach SLIP for the console port.

slip {attach | detach}

Syntax Description

attach

Keyword to activate SLIP for the console port.

detach

Keyword to deactivate SLIP for the console port.

Default

By default, SLIP is not active (detached).

Supported Platforms

Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch

Command Type

Switch command.

Command Mode

Privileged.

Usage Guideline

You can enter the slip command from a console port session or a Telnet session.

Examples

This example shows how to enable SLIP for a console port during a console port session:

Console> (enable) slip attach
Console port now running SLIP.
<console port running SLIP>
 

This example shows how to disable SLIP for a console port during a Telnet session:

Console> (enable) slip detach
SLIP detached on Console port.
<console port back to RS-232 Console>
Console> (enable) 
Related Command

set interface

squeeze

Use the squeeze command to delete Flash files permanently.

squeeze [m/]device:

Syntax Description

m/

(Optional) Module number of the supervisor engine containing the Flash device.

device:

Device where the Flash device resides.

Default

This command has no default setting.

Supported Platforms

Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch

Command Type

Switch command.

Command Mode

Privileged.

Usage Guidelines

A colon (:) is required after the specified device.

This command applies only to the Supervisor Engine III and Catalyst 4000 family and 2948G switch supervisor engine module. If you attempt to run this command on a Supervisor Engine I or II, you will receive an error message.

Examples

These examples show how to use the squeeze command to delete the slot0 Flash files and then use the show flash command to confirm the deletion:

Console> squeeze slot0:
All deleted files will be removed, proceed (y/n) [n]?y
Squeeze operation may take a while, proceed (y/n) [n]?y
..........................................................
Console> show flash
-#- ED --type-- --crc--- -seek-- nlen -length- -----date/time------ name
1 .. 2        43B312DF 100fc0  15   1052608  Aug 12 1998 10:23:30 cat5k_r47_1.cbi
 
7336000 bytes available (1052608 bytes used)
Console>
Related Commands

dirswitch
undelete
show flash

switch

Use the switch command to switch the clock from the supervisor clock to the internal clock or from the active supervisor to the standby supervisor.

switch {clock | supervisor}

Syntax Description

clock

Keyword to switch the clock from the supervisor clock to the internal clock.

supervisor

Keyword to switch from the active supervisor to the standby supervisor (Catalyst 5500 and Catalyst 5505 switches only).

Default

This command has no default setting.

Supported Platforms

Catalyst 5000 family switches

Command Type

Switch command.

Command Mode

Privileged.

Usage Guideline

The switch command is supported only on Catalyst 5500 and Catalyst 5505 switches.

Examples

This example shows how to switch the clock:

Console> (enable) switch clock
This command will reset system and force a clock switch-over.
Do you want to continue (y/n) [n]?
Console> (enable)
 

This example shows how to switch to the standby supervisor:

Console> (enable) switch supervisor
This command will force a switch-over to the standby Supervisor module.
Do you want to continue (y/n) [n]?
Console> (enable)

sync

Use the sync command to write the working in-core copy of environment variables and the aliases out to NVRAM so they are read on the next reset.

sync

Syntax Description

This command has no arguments or keywords.

Default

This command has no default setting.

Supported Platforms

Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch

Command Type

ROM monitor command.

Command Mode

Normal.

Example

This example shows how to use the sync command:

rommon 10 > sync
rommon 11 >

telnet

Use the telnet command to start a Telnet connection to a remote host.

telnet host [port_num]

Syntax Description

host

Name or IP address of the remote host to which you want to connect.

port_num

(Optional) Specific port connection on the remote host.

Default

This command has no default setting.

Supported Platforms

Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch

Command Type

Switch command.

Command Mode

Privileged.

Example

This example shows how to open and close a Telnet session with the host elvis:

Console> (enable) telnet elvis
Trying 192.122.174.11...
Connected to elvis.
Escape character is '^]'.
 
UNIX(r) System V Release 4.0 (elvis)
 
login: fred
Password:
Last login: Thu Jun 11 09:25:01 from forster.cisc.rum
Sun Microsystems Inc.   SunOS 5.4       Generic July 1994
You have new mail.
% logout
 
Console> (enable) 
Related Command

disconnect

test snmp trap

Use the test snmp trap command to send an SNMP trap message to the trap receivers.

test snmp trap trap_num [specific_num]

Syntax Description

trap_num

Number of the trap.

specific_num

(Optional) Number of a predefined trap.

Default

This command has no default setting.

Supported Platforms

Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch

Command Type

Switch command.

Command Mode

Privileged.

Example

This example shows how to run trap 0:

Console> (enable) test snmp trap 0
SNMP trap message sent. (4)
Console> (enable) 
Related Command

set snmp trap

traceroute

Use the traceroute command to display a hop-by-hop path through an IP network from the switch to a specific destination host.

traceroute [-n] [-w wait_time] [-i initial_ttl] [-m max_ttl] [-p dest_port] [-q nqueries] [-t tos] host [data_size]

Syntax Description

-n

(Optional) Prevents traceroute from performing a DNS lookup for each hop on the path. Only numerical IP addresses are printed.

-w wait_time

(Optional) Specifies the amount of time (in seconds) that traceroute will wait for an ICMP response message. The allowed range for wait_time is 1 to 300 seconds; the default is 5 seconds.

-i initial_ttl

(Optional) Causes traceroute to send ICMP datagrams with a TTL value equal to initial_ttl instead of the default TTL of 1. This causes traceroute to skip processing for hosts that are less than initial_ttl hops away.

-m max_ttl

(Optional) Specifies the maximum TTL value for outgoing ICMP datagrams. The allowed range for max_ttl is 1 to 255; the default value is 30.

-p dest_port

(Optional) Specifies the base UDP destination port number used in traceroute datagrams. This value increments each time a datagram is sent. The allowed range for dest_port is 1 to 65535; the default base port is 33434. Use this option in the unlikely event that the destination host is listening to a port in the default traceroute port range.

-q nqueries

(Optional) Specifies the number of datagrams to send for each TTL value. The allowed range for nqueries is 1 to 1000; the default is 3.

-t tos

(Optional) Specifies the TOS to be set in the IP header of the outgoing datagrams. The allowed range for tos is 0 to 255; the default is 0. Use this option to see if different types of service cause routes to change.

host

IP alias or IP address in dot notation (a.b.c.d) of the destination host.

data_size

(Optional) Number of bytes, in addition to the default of 40 bytes, of the outgoing datagrams. The allowed range is 0 to 1420; the default is 0.

Default

Entering the traceroute host command without options sends three 40-byte ICMP datagrams with an initial TTL of 1, a maximum TTL of 30, a timeout period of 5 seconds, and a TOS specification of 0 to destination UDP port number 33434. For each host in the processed path, the initial TTL for each host and the destination UDP port number for each packet sent are incremented by one.

Supported Platforms

Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch

Command Type

Switch command.

Command Mode

Privileged.

Usage Guidelines

To interrupt traceroute after the command has been issued, press Ctrl-C.

The traceroute command uses the TTL field in the IP header to cause routers and servers to generate specific return messages. Traceroute starts by sending a UDP datagram to the destination host with the TTL field set to 1. If a router finds a TTL value of 1 or 0, it drops the datagram and sends back an ICMP "time exceeded" message to the sender. The traceroute facility determines the address of the first hop by examining the source address field of the ICMP time-exceeded message.

To identify the next hop, traceroute again sends a UDP packet but this time with a TTL value of 2. The first router decrements the TTL field by 1 and sends the datagram to the next router. The second router sees a TTL value of 1, discards the datagram, and returns the time-exceeded message to the source. This process continues until the TTL is incremented to a value large enough for the datagram to reach the destination host (or until the maximum TTL is reached).

To determine when a datagram has reached its destination, traceroute sets the UDP destination port in the datagram to a very large value that the destination host is unlikely to be using. When a host receives a datagram with an unrecognized port number, it sends an ICMP "port unreachable" error to the source. This message indicates to the traceroute facility that it has reached the destination.

Catalyst 5000 family, 4000 family, 2926G series, or 2948G switches can participate as the source or destination of the traceroute command. However, because they are Layer 2 devices, Catalyst 5000 family, 4000 family, 2926G series, or 2948G switches do not examine the TTL field in the IP header and therefore do not decrement the TTL field or send ICMP time-exceeded messages. A Catalyst 5000 family, 4000 family, 2926G series, or 2948G switch does not appear as a hop in the traceroute command output.

Example

This example shows how to use the traceroute command to determine the path from the source to the destination host server10:

Console> (enable) traceroute server10
traceroute to server10.company.com (172.16.22.7), 30 hops max, 40 byte packets
 1  engineering-1.company.com (172.31.192.206)  2 ms  1 ms  1 ms
 2  engineering-2.company.com (172.31.196.204)  2 ms  3 ms  2 ms
 3  gateway_a.company.com (172.16.1.201)  6 ms  3 ms  3 ms
 4  server10.company.com (172.16.22.7)  3 ms  *  2 ms
Console> (enable)
 

Table 2-78 describes the fields in the traceroute command output.


Table 2-78: traceroute Command Output Fields
Field Description

30 hops max, 40 byte packets

Maximum TTL value and the size of the ICMP datagrams being sent.

2 ms 1 ms 1 ms

Total time (in milliseconds) for each ICMP datagram to reach the router or host plus the time it took for the ICMP time-exceeded message to return to the host.

An exclamation point following any of these values (for example, 20 ms !) indicates that the port-unreachable message returned by the destination had a TTL of 0 or 1. Typically, this occurs when the destination uses the TTL value from the arriving datagram as the TTL in its ICMP reply. The reply does not arrive at the source until the destination receives a traceroute datagram with a TTL equal to the number of hops between the source and destination.

3 ms * 2 ms

"*" indicates that the timeout period (default of 5 seconds) expired before an ICMP time-exceeded message was received for the datagram.

If traceroute receives an ICMP error message other than a time-exceeded or port-unreachable message, it prints one of the error codes shown in Table 2-79 instead of the round-trip time or an asterisk (*).


Table 2-79: traceroute Error Messages
ICMP Error Code Meaning

!N

No route to host. The network is unreachable.

!H

No route to host. The host is unreachable.

!P

Connection refused. The protocol is unreachable.

!F

Fragmentation needed but do not fragment (DF) bit was set.

!S

Source route failed.

!A

Communication administratively prohibited.

?

Unknown error occurred.

Related Command

ping

unalias

Use the unalias command to remove the alias name and associated value from the alias list.

unalias name

Syntax Description

name

Name of the alias.

Default

This command has no default setting.

Supported Platforms

Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch

Command Type

ROM monitor command.

Command Mode

Normal.

Example

This example shows how to use the unalias command to remove the s alias and then check to ensure it was removed:

rommon 5 > alias
r=repeat
h=history
?=help
b=boot
ls=dir
i=reset
k=stack
s=set
rommon 6 > unalias s
rommon 7 > alias
r=repeat
h=history
?=help
b=boot
ls=dir
i=reset
k=stack
rmmon 8 > s
monitor: command "s" not found
===========================================================================
Related Command

alias

undelete

Use the undelete command to recover a deleted file on a Flash memory device. The deleted file can be recovered using its index (because there could be multiple deleted files with the same name).

undelete index [[m/]device:]

Syntax Description

index

Index number of the deleted file.

m/

(Optional) Module number of the supervisor engine containing the Flash device.

device:

(Optional) Device where the Flash device resides.

Default

This command has no default setting.

Supported Platforms

Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch

Command Type

Switch command.

Command Mode

Privileged.

Usage Guidelines

A colon (:) is required after the specified device.

Use the dir command to learn the index number of the file to be undeleted.

A file cannot be undeleted if a valid file with the same name exists. You must delete the existing file before you can undelete the target file.

A file can be deleted and undeleted up to 15 times.

To delete all deleted files permanently on a device, use the squeeze command.

Example

This example shows how to recover the deleted file with index 1 and use the show flash command to confirm:

Console> (enable) undelete 1 bootflash:
Console> (enable)  show flash
-#- ED --type-- --crc--- -seek-- nlen -length- -----date/time------ name
  1 .. ffffffff a638976e  3627ec   23  3286891 Jan 01 1999 07:04:37 cat5000-supn
  2 .. ffffffff a6a84c93  365f74   17    14086 Jan 29 1999 02:33:56 switch_confg
  3 .. ffffffff 141a9127  70b7cc   29  3823575 Mar 09 1999 19:15:55 cat5000-supn
 
1428272 bytes available (6173904 bytes used)
Console> (enable)
Related Commands

delete
show flash
squeeze

unset=varname

Use the unset=varname command to remove a variable name from the variable list.

unset=varname

Syntax Description

This command has no arguments or keywords.

Default

This command has no defaults.

Supported Platforms

Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch

Command Type

ROM monitor command.

Command Mode

Normal.

Example

This example shows how to use the set command to display the variable list, use the unset command to remove a variable name from the variable list, and then use the set command to display the variable list to verify:

rommon 2 > set 
PS1=rommon ! > 
BOOT=
?=0
rommon 3 > unset=0
rommon 4 > set 
PS1=rommon ! > 
BOOT=
Related Command

varname=

upload

Use the upload command to upload a software image to a network host.

upload host file [mod_num] [rcp | tftp]

Syntax Description

host

IP address or IP alias of the host.

file

Name of the image file.

mod_num

(Optional) Number of the module from which to upload the image file. If no number is specified, the default is module 1.

rcp

(Optional) Keyword to upload a software image to a network host using rcp.

tftp

(Optional) Keyword that allows you to copy to or from a TFTP server.

Default

If you do not specify the type of upload method, TFTP is used.

Supported Platforms

Catalyst 5000 family switches

Command Type

Switch command.

Command Mode

Privileged.

Usage Guidelines

To upload a software image for the RSM, use the session command.

This command is not supported by the three-port Gigabit Ethernet switching module (WS-X5403).

Examples

This example shows how to upload the supervisor image to the c5009_11.bin file on the mercury host:

Console> (enable) upload mercury c5009_11.bin 3
Upload Module 1 image to c5009_11.bin on mercury (y/n) [n]? y
/
Done.  Finished Network Upload.  (153908 bytes)
Console> (enable) 
 

This example shows how to upload the c5000_spv11.bin file from the mercury host to the supervisor engine module:

Console> (enable) upload mercury c5000_spv11.bin rcp
Upload image c5000_spv11.bin from mercury to module 1FLASH (y/n) [n]? y
\
Finished network single module download. (2418396 bytes)
FLASH on Catalyst:
 
Type            Address             Location
Intel 28F008    20000000            NMP (P3) 4MB SIM
 
Erasing flash sector...done.
Programming flash sector...done.
Erasing flash sector...done.
Programming flash sector...done.
The system needs to be reset to run the new image.
Console> (enable)
Related Command

download

varname=

Use the varname= command to set the variable VARNAME to varvalue. The syntax varname= sets the variable to a NULL string.

varname=value

Syntax Description

varname=

Name of the variable.

value

Any ROM monitor command.

Default

This command has no defaults.

Supported Platforms

Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch

Command Type

ROM monitor command.

Command Mode

Normal.

Usage Guideline

Do not put a space before or after the equal (=) sign. If there are spaces, you must place the value in quotes. Spell out variable names in all caps to make them conspicuous.

Example

This example shows how to assign a variable name to a value:

rommon 1 > s=set
rommon 2 > s
PS1=rommon ! >
BOOT=
?=0
Related Command

unset=varname

verify

Use the verify command to confirm the checksum of a file on a Flash device.

verify [[m/]device:] filename

Syntax Description

m/

(Optional) Module number of the supervisor engine containing the Flash device.

device:

(Optional) Device where the Flash device resides.

filename

Name of the configuration file.

Default

This command has no default setting.

Supported Platforms

Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch

Command Type

Switch command.

Command Mode

Privileged.

Usage Guideline

A colon (:) is required after the specified device.

Example

This example shows how to use the verify command:

Console> verify cat5k_r47_1.cbi
..........................................................
File cat5k_r47_1.cbi verified OK.
 

wait

Use the wait command to cause the CLI to pause for a specified number of seconds before executing the next command. This command might be included in a configuration file.

wait seconds

Syntax Description

seconds

Number of seconds for the CLI to wait.

Default

This command has no default setting.

Supported Platforms

Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch

Command Type

Switch command.

Command Mode

Normal.

Example

This example shows how to pause the CLI for 5 seconds:

Console> wait 5
Console> 

write

Use the write command to upload or display non-default configurations to a host or terminal.

write {host file | network | terminal} [rcp] [all]

Syntax Description

host

IP address or IP alias of the host.

file

Name of the configuration file.

network

Keyword to specify interactive prompting for the IP address or IP alias of the host and the filename to upload.

terminal

Keyword to display the non-default configuration file on the terminal.

rcp

(Optional) Keyword to upload a software image to a host using rcp.

all

(Optional) Keyword that specifies all modules and system configuration information, including the IP address.

Default

By default, the write command will upload or output only non-default configurations. Use the keyword all to upload or output both default and non-default configurations.

Supported Platforms

Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch

Command Type

Switch command.

Command Mode

Privileged.

Usage Guidelines

The write host file command is a shorthand version of the write network command.

You cannot use the write network command to upload software to the ATM module. With the write network command, the file must already exist on the host (use the UNIX touch filename command to create the file).

Examples

This sample session assumes that module 1 is a 2-port supervisor module, module 2 is a 12-port 10/100BaseT switched Ethernet module, modules 3 and 5 are empty, and module 4 is an FDDI module. Details of the ATM configuration must be accessed through the special module mode.

This example shows how to upload the system5.cfg file to the mercury host using the write network command:

Console> (enable) write network
IP address or name of host? mercury
Name of configuration file to write? system5.cfg
Upload configuration to system5.cfg on mercury (y/n) [y]? y
/
Done.  Finished Network Upload.  (9003 bytes)
Console> (enable) 
 

This example shows how to upload the system5.cfg file to the mercury host using the write network rcp command:

Console> (enable) write network rcp
IP address or name of host? mercury
Name of configuration file to write? system5.cfg
Upload configuration to system5.cfg on mercury (y/n) [y]? y
/
Done.  Finished Network Upload.  (9003 bytes)
Console> (enable) 
 

This example shows how to upload the system5.cfg file to the mercury host using the writehostfile command as a shorthand method:

Console> (enable) write mercury system5.cfg
Upload configuration to system5.cfg on mercury (y/n) [y]? y
/
Done.  Finished Network Upload.  (9003 bytes)
Console> (enable) 
 

This example shows how to use the write terminal all command to display the entire (default and non-default) configuration file on the terminal:

Console> (enable) write terminal
begin
set password $1$FMFQ$HfZR5DUszVHIRhrz4h6V70
set enablepass $1$FMFQ$HfZR5DUszVHIRhrz4h6V70
set prompt Console>
!
#system
set system baud 9600
set system modem  disable
set system name
set system location
set system contact
!
#snmp
set snmp community read-only public
set snmp community read-write private
set snmp community read-write-all secret
set snmp trap  disable
!
#vlan/trunk
set vlan 1    1/1-2,4/1
set vlan 2    2/1-5
!
#trunks
!
#cam
set cam agingtime 1    300
set cam agingtime 2    300
!
#ip
set interface sc0 0.0.0.0 0.0.0.0 0.0.0.0
set interface sl0 0.0.0.0 0.0.0.0
set ip redirect      enable
set ip unreachable   disable
set ip fragmentation enable
set ip alias default         0.0.0.0
set arp agingtime 1200
!
#bridge
set bridge ipx snaptoether   8023raw
set bridge ipx 8022toether   8023
set bridge ipx 8023rawtofddi snap
!
#Command alias
!
#cdp
set cdp enable   1/1-2,2/1-5,4/1
set cdp interval 1/1  60
set cdp interval 1/2  60
set cdp interval 2/1  60
set cdp interval 2/2  60
set cdp interval 2/3  60
set cdp interval 2/4  60
set cdp interval 2/5  60
set cdp interval 4/1  60
!
#spantree
#vlan 1
set spantree enable         1
set spantree fwddelay 15    1
set spantree hello    2     1
set spantree maxage   20    1
set spantree priority 32768 1
set spantree portpri  1/1  32
set spantree portcost 1/1  10
set spantree portpri  1/2  32
set spantree portcost 1/2  10
set spantree portpri  4/1  32
set spantree portcost 4/1  10
#vlan 2
set spantree enable         2
set spantree fwddelay 15    2
set spantree hello    2     2
set spantree maxage   20    2
set spantree priority 32768 2
set spantree portpri  2/1  32
set spantree portcost 2/1  100
set spantree portpri  2/2  32
set spantree portcost 2/2  100
set spantree portpri  2/3  32
set spantree portcost 2/3  100
set spantree portpri  2/4  32
set spantree portcost 2/4  100
set spantree portpri  2/5  32
set spantree portcost 2/5  100
!
#trunk
!
#module 1
set module name    1
set port enable    1/1
set port name      1/1
set port duplex    1/1  half
set port level     1/1  normal
set port enable    1/2
set port name      1/2
set port duplex    1/2  half
set port level     1/2  normal
!
#module 2
set module name    2
set module enable  2
!
set port enable    2/1
set port name      2/1
set port duplex    2/1  half
set port level     2/1  normal
set port enable    2/2
set port name      2/2
set port duplex    2/2  half
set port level     2/2  normal
set port enable    2/3
set port name      2/3
set port duplex    2/3  half
set port level     2/3  normal
set port enable    2/4
set port name      2/4
set port duplex    2/4  half
set port level     2/4  normal
set port enable    2/5
set port name      2/5
set port duplex    2/5  half
set port level     2/5  normal
!
#module 3 empty
!
#module 4
set module name    4
set module enable  4
!
set fddi userdata  4 WorkGroup Stack
set fddi tnotify   4 30
set fddi treq      4 5000
set port enable    4/1
set port name      4/1
set port level     4/1  normal
set fddi tlmin     4/1  40
set port enable    4/2
set port name      4/2
set port level     4/2  normal
set fddi tlmin     4/2  40
!
#module 5 empty
end
Console> (enable)
Related Commands

show config
copy

write terminal

Use the write terminal command to display the configuration information currently in running memory.

write terminal all

Syntax Description

all

(Optional) Keyword that specifies all configuration information.

Default

This command has no default setting

Supported Platforms

Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch

Command Type

Switch command.

Command Mode

Privileged.

Usage Guideline

You can also use this command in EXEC mode to display the current configuration information. This usage is not supported by the Catalyst 4000 family and 2948G switches.

Examples

This example shows how to display the current system configuration information:

Console> (enable) write terminal
......
 
...............
 
..
 
begin
!
# ***** NON-DEFAULT CONFIGURATION *****
!
!
#Time: Tue Aug 3 1999, 07:32:26 
!
#version 5.3(0.90)ASP
!
!       
#frame distribution method
set port channel all distribution mac both
!
#vtp
set vtp domain Lab_Network
set vtp pruning enable
set vlan 1 name default type ethernet mtu 1500 said 100001 state active 
set vlan 2 name VLAN0002 type ethernet mtu 1500 said 100002 state active 
set vlan 3 name VLAN0003 type ethernet mtu 1500 said 100003 state active 
set vlan 4 name VLAN0004 type ethernet mtu 1500 said 100004 state active 
set vlan 5 name VLAN0005 type ethernet mtu 1500 said 100005 state active 
set vlan 6 name VLAN0006 type ethernet mtu 1500 said 100006 state active 
set vlan 10 name VLAN0010 type ethernet mtu 1500 said 100010 state active 
set vlan 20 name VLAN0020 type ethernet mtu 1500 said 100020 state active 
set vlan 50 name VLAN0050 type ethernet mtu 1500 said 100050 state active 
set vlan 100 name VLAN0100 type ethernet mtu 1500 said 100100 state active 
set vlan 152 name VLAN0152 type ethernet mtu 1500 said 100152 state active 
set vlan 200 name VLAN0200 type ethernet mtu 1500 said 100200 state active 
set vlan 300 name VLAN0300 type ethernet mtu 1500 said 100300 state active 
set vlan 303 name VLAN0303 type fddi mtu 1500 said 100303 state active 
set vlan 304 name VLAN0304 type fddi mtu 1500 said 100304 state active 
set vlan 305 name VLAN0305 type fddi mtu 1500 said 100305 state active 
set vlan 349 name VLAN0349 type fddi mtu 1500 said 100349 state active 
set vlan 350 name VLAN0350 type fddi mtu 1500 said 100350 state active 
set vlan 351 name VLAN0351 type fddi mtu 1500 said 100351 state active 
set vlan 400 name VLAN0400 type ethernet mtu 1500 said 100400 state active 
set vlan 500 name VLAN0500 type ethernet mtu 1500 said 100500 state active 
set vlan 521 name VLAN0521 type ethernet mtu 1500 said 100521 state active 
set vlan 524 name VLAN0524 type ethernet mtu 1500 said 100524 state active 
set vlan 570 name VLAN0570 type ethernet mtu 1500 said 100570 state active 
set vlan 801 name VLAN0801 type trbrf mtu 4472 said 100801 state active bridge  
set vlan 850 name VLAN0850 type ethernet mtu 1500 said 100850 state active 
set vlan 917 name VLAN0917 type ethernet mtu 1500 said 100917 state active 
set vlan 999 name VLAN0999 type ethernet mtu 1500 said 100999 state active 
set vlan 1002 name fddi-default type fddi mtu 1500 said 101002 state active 
set vlan 1004 name fddinet-default type fddinet mtu 1500 said 101004 state acti 
set vlan 1005 name trnet-default type trbrf mtu 1500 said 101005 state active b 
set vlan 802 name VLAN0802 type trcrf mtu 4472 said 100802 state active parent  
set vlan 1003 name token-ring-default type trcrf mtu 1500 said 101003 state act 
set vlan 3 translation 303 translation 0
set vlan 4 translation 304 translation 0
set vlan 5 translation 305 translation 0
set vlan 303 translation 3 translation 0
set vlan 304 translation 4 translation 0
set vlan 305 translation 5 translation 0
set vlan 351 translation 524 translation 0
set vlan 524 translation 351 translation 0
!
#ip
set interface sc0 5 172.20.52.124/255.255.255.248 172.20.52.127
 
set ip route 0.0.0.0/0.0.0.0         172.20.52.125  
!
#spantree
#vlan 801
set spantree fwddelay 4     801
set spantree maxage   10    801
#vlan 802
set spantree fwddelay 4     802
set spantree maxage   10    802
set spantree portstate 802 block 801
!
#set boot command
set boot auto-config non-recurring
!
#Port Channel
set port channel 7/7-8 3
set port channel 7/5-6 21
!       
#module 1 : 2-port 1000BaseX Supervisor IIIG
!
#module 2 empty
!
#module 3 : 2-port DS3 Dual PHY ATM
!
#module 4 empty
!
#module 5 empty
!
#module 6 : 48-port 10BaseT Ethernet
!
#module 7 : 24-port 10/100BaseTX Ethernet
set trunk 7/1  desirable isl 1-1005
set trunk 7/2  desirable isl 1-1005
set trunk 7/3  desirable isl 1-1005
set trunk 7/4  desirable isl 1-1005
nt7/1-6 mode desirable silent
!
#module 8 empty
!
#module 9 empty
!       
#module 15 empty
!
#module 16 empty
end
Console> (enable) 

hometocprevnextglossaryfeedbacksearchhelp