cc/td/doc/product/lan/cat5000/rel_5_2
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

show rif
show rsmautostate
show snmp
show span
show spantree
show spantree backbonefast
show spantree blockedports
show spantree portstate
show spantree portvlancost
show spantree statistics
show spantree summary
show spantree uplinkfast
show standbyports
show station controltable
show station ordertable
show summertime
show system
show tacacs
show test

show rif

Use the show rif command to display RIF information.

show rif [vlan_num]

Syntax Description

vlan_num

(Optional) Number of the VLAN that you want to view RIF information.

Default

This command has no default setting.

Supported Platforms

Catalyst 5000 family switches

Command Type

Switch command.

Command Mode

Normal.

Examples

This example shows how to display RIF information for the system and for a VLAN:

Console> show rif
MAC                  VLAN     RIF
-------------------- -------- --------------------
00:00:30:e2:cf:00 on 401  via 0610.001a.0020
00:05:77:01:bc:4a on 1020 via 0690.00d1.00e2
00:05:77:01:bc:4b on 1020 via 0690.00d1.00e2
00:05:77:01:bc:48 on 1020 via 0690.00d1.00e2
 

This example shows how to display RIF information for a VLAN:

Console> show rif 401
MAC                  VLAN     RIF
-------------------- -------- --------------------
00:00:30:e2:cf:00 on 401  via 0610.001a.0020
Console>

show rsmautostate

Use the show rsmautostate command to display the current status of line protocol state determination of the RSMs caused by Catalyst 5000 family and 2926G series switch port state change.

show rsmautostate mod_num

Syntax Description

mod_num

Number of the module.

Default

This command has no default setting.

Supported Platforms

Catalyst 5000 family switches

Command Type

Switch command.

Command Mode

Normal.

Example

This example shows how to display the current status of RSM line protocol state determination:

Console> show rsmautostate
RSM Auto port state: enabled
Console>
 

show snmp

Use the show snmp command to display SNMP information.

show snmp [noalias]

Syntax Description

noalias

(Optional) Keyword that forces the display to show IP address, not IP aliases.

Default

This command has no default setting.

Supported Platforms

Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch

Command Type

Switch command.

Command Mode

Normal.

Examples

This example shows how to display SNMP information:

Console> show snmp
RMON: Enabled
Traps Enabled: Chassis
Port Traps Enabled: None
 
Community-Access     Community-String
----------------     --------------------
read-only            public
read-write           private
read-write-all       secret
 
Trap-Rec-Address                           Trap-Rec-Community
----------------------------------------   --------------------
192.122.173.42                             public
Console> 
 
This example shows the SNMP information displayed when a Network Analysis Module is installed:
Console> show snmp
RMON: Enabled
Traps Enabled: Chassis
Port Traps Enabled: None
Community-Access     Community-String
----------------     --------------------
read-only            public
read-write           private
read-write-all       secret
 
Trap-Rec-Address                           Trap-Rec-Community
----------------------------------------   --------------------
192.122.173.42                             public
 
Extended Rmon:              Disabled
Extended RMON Netflow:      Disabled
Extended RMON Vlanmode:     Disabled
Extended RMON Vlanagent:    Disabled
 

Table 2-55 describes the possible fields (depending on the port type queried) in the show snmp command output.


Table 2-55: show snmp Command Output Fields
Field Description

RMON

Status of whether RMON is enabled or disabled.

Traps Enabled

Trap types that are enabled.

Port Traps Enabled

Set of ports whose linkup/linkdown trap is enabled.

Community-Access

Configured SNMP communities.

Community-String

SNMP community strings associated with each SNMP community.

Trap-Rec-Address

IP address or IP alias of trap receiver hosts.

Trap-Rec-Community

SNMP community string used for trap messages to the trap receiver.

Extended Rmon

Status of whether extended RMON is enabled or disabled.

Extended RMON Netflow

Status of whether Netflow Monitor option is enabled or disabled.

Extended RMON Vlanmode

Status of whether VLAN Monitor option is enabled or disabled.

Extended RMON Vlanagent

Status of whether VLANagent option is enabled or disabled.

Related Commands

set snmp rmon
set snmp trap

show span

Use the show span command to display information about the current SPAN configuration:

show span

Syntax Description

This command has no keywords or arguments.

Default

This command has no default setting.

Supported Platforms

Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch

Command Type

Switch command.

Command Mode

Normal.

Usage Guideline

SPAN in the context of a single module is the only possible configuration for Token Ring modules.

Example

This example shows how to display SPAN information for the switch:

Console> (enable) show span
Destination:  Port 4/1
Admin Source:  Port 3/1-6
Oper Source:  Port 3/1-5
Direction:  transmit/receive
Incoming Packets:  enabled
Console> (enable)
 
 

Table 2-56 describes the fields in the show span command output.

Table 2-56: show span Command Output Fields
Field Description

Destination

Destination port for SPAN information.

Admin Source

Source port or VLAN for SPAN information.

Oper Source

Operator port or VLAN for SPAN information.

Direction

Status of whether transmit, receive, or transmit/receive information is monitored.

Incoming Packets

Status of whether reception of normal incoming packets on the SPAN destination port is enabled or disabled.

Related Commands

clear config
set span

show spantree

Use the show spantree command to display spanning-tree information for a VLAN.

show spantree [vlan | mod_num/port_num] [active]

Syntax Description

vlan

(Optional) Number of the VLAN. If the VLAN number is not specified, the default is VLAN 1.

mod_num

(Optional) Number of the module.

port_num

(Optional) Number of the port on the module.

active

(Optional) Keyword to display only the active ports.

Default

This command has no default setting.

Supported Platforms

Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch

Command Type

Switch command.

Command Mode

Normal.

Usage Guideline

The Catalyst 2948G switch is a fixed configuration switch. All ports are located on module 2; for this reason, if you enter mod_num/port_num 1/N, an error message will be displayed.

Examples

This example shows how to display the spanning-tree configuration for VLAN 1005:

Console> show spantree 1005
VLAN 1005
Spanning tree enabled
 
Designated Root             00-40-0b-8f-8b-ec
Designated Root Priority    32768
Designated Root Cost        0
Designated Root Port        1/0
Root Max Age   6  sec    Hello Time 2  sec   Forward Delay 4  sec
 
Bridge ID MAC ADDR          00-40-0b-8f-8b-ec
Bridge ID Priority          32768
Bridge Max Age 6  sec    Hello Time 2  sec   Forward Delay 4  sec
 
Port,Vlan Vlan  Port-State     Cost   Priority  Fast-Start  Group-method
--------- ----  -------------  -----  --------  ----------  ------------
 1003     1005  inactive          80        32   disabled
Console> 
 

This example shows how to display only the active ports:

Console> show spantree active
VLAN 1
Spanning tree enabled
Spanning tree type          ieee
 
Designated Root             00-60-70-4c-70-00
Designated Root Priority    32768
Designated Root Cost        19
Designated Root Port        1/1
Root Max Age   20 sec    Hello Time 2  sec   Forward Delay 15 sec
 
Bridge ID MAC ADDR          00-e0-1e-9b-2e-00
Bridge ID Priority          32768
Bridge Max Age 20 sec    Hello Time 2  sec   Forward Delay 15 sec
 
Port      Vlan  Port-State     Cost   Priority  Fast-Start  Group-Method
--------- ----  -------------  -----  --------  ----------  ------------
 1/1      1     forwarding        19        32   disabled              
 3/1-2    1     forwarding        19        32   disabled    redundancy
 

Table 2-57 describes the possible fields in the show spantree command output.


Table 2-57: show spantree Command Output Fields
Field Description

VLAN

VLAN for which spanning-tree information is shown.

Spanning tree

Status of whether Spanning-Tree Protocol is enabled or disabled.

Designated Root

MAC address of the designated spanning-tree root bridge.

Designated Root Priority

Priority of the designated root bridge.

Designated Root Cost

Total path cost to reach the root.

Designated Root Port

Port through which the root bridge can be reached (shown only on nonroot bridges).

Root Max Age

Amount of time a BPDU packet should be considered valid.

Hello Time

Number of times the root bridge sends BPDUs.

Forward Delay

Amount of time the port spends in listening or learning mode.

Bridge ID MAC ADDR

Bridge MAC address.

Bridge ID Priority

Bridge priority.

Bridge Max Age

Bridge maximum age.

Hello Time

Amount of time the bridge sends BPDUs.

Forward Delay

Amount of time the bridge spends in listening or learning mode.

Port

Port number.

Vlan

VLAN to which the port belongs.

Port-State

Spanning-tree port state (disabled, inactive, not-connected, blocking, listening, learning, forwarding, bridging, or type-pvid-inconsistent).

Cost

Cost associated with the port.

Priority

Priority associated with the port.

Fast-Start

Status of whether the port is configured to use the fast-start feature.

Group-Method

Method of how the multiple ports are treated (redundancy=dual PHY and FDDI; repeater=RSM; channel=Fast EtherChannel).

show spantree backbonefast

Use the show spantree backbonefast command to display whether the spanning-tree Backbone Fast Convergence feature is enabled.

show spantree backbonefast

Syntax Description

This command has no arguments or keywords.

Default

This command has no default setting.

Supported Platforms

Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch

Command Type

Switch command.

Command Mode

Normal.

Example

This example shows how to display whether the spanning-tree Backbone Fast Convergence feature is enabled:

Console> show spantree backbonefast
Backbonefast is enabled.
Console> 

show spantree blockedports

Use the show spantree blockedports command to display only the blocked ports.

show spantree blockedports [vlan_num]

Syntax Description

vlan_num

(Optional) Number of the VLAN.

Default

This command has no default setting.

Supported Platforms

Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch

Command Type

Switch command.

Command Mode

Normal.

Usage Guideline

If you do not specify a VLAN number, all blocked ports in the system are displayed.

Example

This example shows how to display the blocked ports for VLAN 1002:

Console> show spantree blockedports 1002
Number of blocked ports (segments) in VLAN 1002 : 0
Console> 
Related Command

show spantree

show spantree portstate

Use the show spantree portstate command to determine the current spanning-tree state of a Token Ring port within a spanning tree.

show spantree portstate [trcrf ]

Syntax Description

trcrf

(Optional) Token Ring concentrator relay function statistical information.

Default

This command has no default setting.

Supported Platforms

Catalyst 5000 family switches

Command Type

Switch command.

Command Mode

Normal.

Example

This example shows how to display the current spanning-tree state of a Token Ring port within a spanning tree:

Console> show spantree portstate 1003
Port,Vlan Vlan  Port-State     Cost   Priority  Fast-Start  Group-method
--------- ----  -------------  -----  --------  ----------  ------------
 1003     1005  inactive          80         4   disabled
* = portstate set by user configuration
Console>
Related Command

set spantree portstate

show spantree portvlancost

Use the show spantree portvlancost command to show the path cost for the VLANs on a port.

show spantree portvlancost mod_num/port_num

Syntax Description

mod_num

Number of the module.

port_num

Number of the port.

Default

This command has no default setting.

Supported Platforms

Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch

Command Type

Switch command.

Command Mode

Normal.

Usage Guideline

The Catalyst 2948G switch is a fixed configuration switch. All ports are located on module 2; for this reason, if you enter mod_num/port_num 1/N, an error message will be displayed.

Example

This example shows how to display the path cost for the VLANs on port 2/12:

Console> show spantree portvlancost 2/12
Port 2/12 VLANs 1-1005 have path cost 19.
Console> 
Related Command

show spantree
set spantree portvlancost

show spantree statistics

Use the show spantree statistics command to show spanning-tree statistical information.

show spantree statistics mod_num/port_num [vlan]
show spantree statistics {trcrf | trbrf}

Syntax Description

mod_num

Number of the module.

port_num

Number of the port.

vlan

(Optional) Number of the VLAN.

trcrf

Number of the Token Ring concentrator relay function VLAN.

trbrf

Number of the Token Ring bridge relay function VLAN.

Default

This command has no default setting.

Supported Platforms

Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch

Command Type

Switch command.

Command Mode

Normal.

Usage Guidelines

The trcrf and trbrf arguments are not supported by the Catalyst 4000 family and 2948G switches.

The Catalyst 2948G switch is a fixed configuration switch. All ports are located on module 2; for this reason, if you enter mod_num/port_num 1/N, an error message will be displayed.

Example

This example shows how to display Token Ring concentrator relay function statistical information:

Console> (enable) show spantree statistics 1003 1005
TR CRF 1003, TR BRF 1005
 
SpanningTree enabled for vlanNo = 1005
 
                BPDU-related parameters
port spanning tree                   enabled
state                                disabled
port_id                              0xcccf
port number                          0x7eb
path cost                            80
message age (port/VLAN)              0(10)
designated_root                      00-10-2f-52-eb-ec
designated_cost                      0
designated_bridge                    00-10-2f-52-eb-ec
designated_port                      0xcccf
top_change_ack                       FALSE
config_pending                       FALSE
port_inconsistencynone
 
                PORT based information & statistics
config bpdu's xmitted (port/VLAN)    0(0)
config bpdu's received (port/VLAN)   0(0)
tcn bpdu's xmitted (port/VLAN)       0(0)
tcn bpdu's received (port/VLAN)      0(0)
forward trans count                  0
scp failure count0
 
                Status of Port Timers
forward delay timer                  INACTIVE
forward delay timer value            0
message age timer                    INACTIVE
message age timer value              0
topology change timer                INACTIVE
topology change timer value          0
hold timer                           INACTIVE
hold timer value                     0
delay root port timer                INACTIVE
delay root port timer value          0
 
                VLAN based information & statistics
spanningtree type                    ibm
spanningtree multicast address       c0-00-00-00-01-00
bridge priority                      32768
bridge mac address                   00-10-2f-52-eb-ec
bridge hello time                    2 sec
bridge forward delay                 4 sec
topology change initiator:           1/0
topology change                      FALSE
topology change time                 14
topology change detected             FALSE
topology change count                0
topology change last recvd. from 00-00-00-00-00-00
 
                Other port-specific info
dynamic max age transitions          0
port bpdu ok count                   0
msg age expiry count                 0
link loading                         1
bpdu in processing                   FALSE
num of similar bpdus to process      0
next state                           0
src mac count:                       0
total src mac count                  0
curr_src_mac                         00-00-00-00-00-00
next_src_mac                         00-00-00-00-00-00
channel_src_mac                      00-00-00-00-00-00
channel src count                    0
channel ok count                     0
Console> (enable)
 

Table 2-58 describes the possible fields in the show spantree statistics command output.


Table 2-58: show spantree statistics Command Output Fields
Field Description
BPDU-related parameters

port spanning tree

Status of whether Spanning-Tree Protocol is enabled or disabled on the port.

state

Spanning-tree port state (Disabled, Listening, Learning, Forwarding, or Blocking).

port_id

Port identifier of the associated port.

port number

Port number.

path cost

Contribution of the path through this root port. This applies to the total path cost to the root for this bridge.

message age (port/VLAN)

Age of the received protocol information recorded for a port and the value of the Max Age parameter (shown in parenthesis) recorded by the switch.

designated_root

MAC address of the designated spanning-tree root bridge.

designated_cost

Cost of the path to the root offered by the designated port on the LAN to which this port is attached.

designated_bridge

Bridge identifier of the bridge assumed to be the Designated Bridge for the LAN associated with the port.

designated_port

Port identifier of the Bridge Port assumed to be the Designated Port for the LAN associated with the port.

top_change_ack

Value of the Topology Change Acknowledgment flag in the next configured BPDU to be transmitted on the associated port. The flag is set in reply to a Topology Change Notification BPDU.

config_pending

Boolean parameter set to record that a configured BPDU should be transmitted on expiration of the hold timer for the associated port.

port_inconsistency

Status of whether the port is in an inconsistent (PVID or port type) state or not.

PORT-based information and statistics

config bpdu's xmitted (port/VLAN)

Number of BPDUs transmitted from the port. The number in parentheses is the number of configured BPDUs transmitted by the switch for this instance of spanning-tree.

config bpdu's received (port/VLAN)

Number of BPDUs received by this port. The number in parentheses is the number of configured BPDUs received by the switch for this instance of spanning-tree.

tcn bpdu's xmitted (port/VLAN)

Number of TCN BDPUs transmitted on this port.

tcn bpdu's received (port/VLAN)

Number of TCN BPDUs received on this port.

forward trans count

Number of times the port state transitioned to FORWARDing state.

scp failure count

Number of SCP failures.

Status of Port Timers

forward delay timer

Status of the forward delay timer. This timer monitors the time spent by a port in the Listening and Learning States.

forward delay timer value

Current value of the forward delay timer.

message age timer

Status of the message age timer. This timer measures the age of the received protocol information recorded for a port.

message age timer value

Current value of the message age timer.

topology change timer

Status of the topology change timer. This timer determines the time period in which configured BPDUs are transmitted with the topology change flag set by the bridge when it is root following the detection of a topology change.

topology change timer value

Current value of the topology change timer.

hold timer

Status of the hold timer. This timer ensures that configured BPDUs are not transmitted too frequently through any bridge port.

hold timer value

Current value of the hold timer.

delay root port timer

Status of the delay root port timer. This timer enables fast convergence on linkup when the UplinkFast feature is enabled.

delay root port timer value

Current value of the delay root port timer.

VLAN-based information and statistics

spanningtree type

Type of spanning tree (IEEE, IBM, CISCO).

spanningtree multicast address

Destination address used to send out configured BPDUs on a bridge port.

bridge priority

Part of the bridge identifier and is taken as the most significant part bridge ID comparisons.

bridge mac address

Bridge Mac address.

bridge hello time

Value of the Hello Time parameter when the bridge is the root or is attempting to become the root.

bridge forward delay

Value of the Forward Delay parameter when the bridge is the root or is attempting to become the root.

topology change

Time the last topology change occurred.

topology change initiator:

Number of the port that caused the topology change.

topology change

Number of times configured BPDUs have been transmitted by the bridge on the LANs for which the bridge is the designated bridge.

topology change time

Time period for which BPDUs are transmitted with the topology change flag set by the bridge when it is the root following the detection of a topology change. It is equal to the sum of the bridge's Max Age and Forward Delay parameters.

topology change detected

Number of topology changes that have been detected by or notified to the bridge.

topology change count

Number of times the topology change has occurred.

topology change last recvd. from

MAC address of the bridge that transmitted the last TCN BPDU.

Other port-specific info

dynamic max age transitions

Number of dynamic max age transitions.

port bpdu ok count

Number of reported port BPDU counts.

msg age expiry count

Number of message age expires.

link loading

Status of whether the link is oversubscribed.

bpdu in processing

Status of whether the BPDU is under processing.

num of similar bpdus to process

Number of similar BPDUs to process that are received on a specific port.

received_inferior_bpdu

Status of whether the port received an inferior BPDU or in response to an RLQ BPDU.

next state

Port state before it is actually set by spanning tree, to facilitate other tasks in using the new value.

src mac count:

Number of BPDUs with the same source MAC address.

total src mac count

Number of BPDUs with all the source MAC addresses.

curr_src_mac

Source MAC address of the configured BPDU received on a particular port.

next_src_mac

MAC address from the different source.

channel_src_mac

Source MAC address of the channel port. It is used to detect channel misconfiguration and avoid spanning-tree loops.

channel src count

Number of times channel_src_mac gets changed and if the limit is exceeded, a channel misconfiguration is detected.

channel ok count

Boolean flag which records the channel status.

Related Commands

show spantree
clear spantree statistics

show spantree summary

Use the show spantree summary command to display a summary of spanning-tree information.

show spantree summary

Syntax Description

This command has no arguments or keywords.

Default

This command has no default setting.

Supported Platforms

Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch

Command Type

Switch command.

Command Mode

Normal.

Example

This example shows how to display a summary of spanning-tree information:

Console> show spantree summary
Summary of connected spanning tree ports by vlan
 
Uplinkfast disabled for bridge.
Backbonefast enabled for bridge.
 
Vlan  Blocking Listening Learning Forwarding STP Active
----- -------- --------- -------- ---------- ----------
   1         0         0        0          1          1
 
      Blocking Listening Learning Forwarding STP Active
----- -------- --------- -------- ---------- ----------
Total        0         0        0          1          1
 
 
BackboneFast statistics
-----------------------
Number of inferior BPDUs received (all VLANs)  : 0
Number of RLQ req PDUs received (all VLANs)    : 0
Number of RLQ res PDUs received (all VLANs)    : 0
Number of RLQ req PDUs transmitted (all VLANs) : 0
Number of RLQ res PDUs transmitted (all VLANs) : 0
Console> 
Related Command

show spantree

show spantree uplinkfast

Use the show spantree uplinkfast command to show the uplinkfast settings.

show spantree uplinkfast

Syntax Description

This command has no arguments or keywords.

Default

This command has no default setting.

Supported Platforms

Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch

Command Type

Switch command.

Command Mode

Normal.

Example

This example shows how to display the uplinkfast settings:

Console> show spantree uplinkfast
VLAN port list 	
------------------------------------------------
1-20   1/1(fwd),1/2-1/5
21-50  1/9(fwd), 1/6-1/8, 1/10-1/12
51-100 2/1(fwd), 2/12
Console> 
Related Commands

show spantree
set spantree uplinkfast
clear spantree uplinkfast

show standbyports

Use the show standbyports command to display the current status of the standby ports feature. The standby ports feature allows the ports on the standby supervisor engine module to pass traffic. If this feature is disabled, the ports are in standby mode.

show standbyports

Syntax Description

This command has no arguments or keywords.

Default

This command has no default setting.

Supported Platforms

Catalyst 5000 family switches

Command Mode

Normal.

Command Type

Switch command.

Example

This example shows how to display the current status of the standby ports feature:

Console> show standbyports
Standby ports feature enabled
Console> 
Related Command

set standbyports

show station controltable

Use the show station controltable command to display a collection of statistics and status information associated with each Token Ring station on the local ring. In addition, this command provides status information for each ring being monitored.

show station controltable [mod_num[/port_num]]

Syntax Description

mod_num

(Optional) Number of the module.

/port_num

(Optional) Number of the port on the module.

Default

This command has no default setting.

Supported Platforms

Catalyst 5000 family switches

Command Type

Switch command.

Command Mode

Normal.

Usage Guidelines

This command is only supported on Token Ring modules.

Example

This example shows how to display a collection of statistics and status information associated with each Token Ring station on Token Ring module 3:

Console> show station controltable 3
Port    TableSize          ActiveStation      RingState
-----   -----------------  -----------------  -----------------
 3/1    0                  0                  Normal Operation
 3/2    0                  0                  Normal Operation
 3/3    0                  0                  Normal Operation
 3/4    0                  0                  Normal Operation
 3/5    0                  0                  Normal Operation
 3/6    0                  0                  Normal Operation
 3/7    0                  0                  Normal Operation
 3/8    0                  0                  Normal Operation
 3/9    0                  0                  Normal Operation
 3/10   0                  0                  Normal Operation
 3/11   0                  0                  Normal Operation
 3/12   0                  0                  Normal Operation
 3/13   0                  0                  Normal Operation
 3/14   0                  0                  Normal Operation
 3/15   0                  2                  Normal Operation
 3/16   0                  0                  Normal Operation
Port    BeaconSender       BeaconNAUN         OrderChanges
-----   -----------------  -----------------  -----------------
 3/1    00:00:00:00:00:00  00:00:00:00:00:00  0
 3/2    00:00:00:00:00:00  00:00:00:00:00:00  0
 3/3    00:00:00:00:00:00  00:00:00:00:00:00  0
 3/4    00:00:00:00:00:00  00:00:00:00:00:00  0
 3/5    00:00:00:00:00:00  00:00:00:00:00:00  0
 3/6    00:00:00:00:00:00  00:00:00:00:00:00  0
 3/7    00:00:00:00:00:00  00:00:00:00:00:00  0
 3/8    00:00:00:00:00:00  00:00:00:00:00:00  0
 3/9    00:00:00:00:00:00  00:00:00:00:00:00  0
 3/10   00:00:00:00:00:00  00:00:00:00:00:00  0
 3/11   00:00:00:00:00:00  00:00:00:00:00:00  0
 3/12   00:00:00:00:00:00  00:00:00:00:00:00  0
 3/13   00:00:00:00:00:00  00:00:00:00:00:00  0
 3/14   00:00:00:00:00:00  00:00:00:00:00:00  0
 3/15   00:00:00:00:00:00  00:00:00:00:00:00  1
 3/16   00:00:00:00:00:00  00:00:00:00:00:00  0
Console> 
 

Table 2-59 describes the fields in the show station controltable command output.


Table 2-59: show station controltable Command Output Fields
Field Description

Port

Module and port number.

TableSize

Number of Token Ring station entries in the table associated with this port.

ActiveStation

Number of active Token Ring station entries in the table associated with this port.

RingState

Current status of the ring.

BeaconSender

Address of the sender of the last beacon frame received on this ring. If no beacon frames have been received, this object shall be equal to six octets of zero.

BeaconNAUN

Address of the nearest upstream neighbor in the last beacon frame received on this ring. If no beacon frames have been received, this object shall be equal to six octets
of zero.

OrderChanges

Number of add and delete events in the table associated with this port.

Related Commands

show counters
show station ordertable

show station ordertable

Use the show station ordertable command to display a listing of the order of stations on the monitored rings.

show station ordertable [mod_num[/port_num]]

Syntax Description

mod_num

(Optional) Number of the module.

/port_num

(Optional) Number of the port on the module.

Default

This command has no default setting.

Supported Platforms

Catalyst 5000 family switches

Command Type

Switch command.

Command Mode

Normal.

Example

This example shows how to display a listing of the order of stations on the Token Ring module 3:

Console> show station ordertable 3
Port    OrderIndex         Address
-----   ---------------    -----------------
 3/15   1                  00:05:77:05:40:63
        2                  00:00:30:cf:a0:98
Console> 
 

Table 2-60 describes the fields in the show station ordertable command output.


Table 2-60: show station ordertable Command Output Fields
Field Description

Port

Module and port number.

OrderIndex

Location of the station with respect to other stations on the ring.

Address

Physical address of the station.

Related Commands

show counters
show station controltable

show summertime

Use the show summertime command to display the current status of the summertime feature.

show summertime

Syntax Description

This command has no arguments or keywords.

Default

This command has no default setting.

Supported Platforms

Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch

Command Type

Switch command.

Command Mode

Normal.

Example

This example shows how to display the current status of the summertime feature:

Console> show summertime
Summertime is enabled and set to 'pst'
Console>
 

The output indicates whether the feature is enabled or disabled and the time zone configured for use with the feature.

Related Command

set summertime

show system

Use the show system command to display system information.

show system

Syntax Description

This command has no keywords or arguments.

Default

This command has no default setting.

Supported Platforms

Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch

Command Type

Switch command.

Command Mode

Normal.

Usage Guideline

In a Token Ring module, the values shown for Traffic and Peak are the average of three switching buses.

Example

This example shows the system status and other information:

Console> show system
PS1-Status PS2-Status Fan-Status Temp-Alarm Sys-Status Uptime d,h:m:s Logout
---------- ---------- ---------- ---------- ---------- -------------- ---------
ok         none       ok         off        ok         3,02:08:53     20 min
 
PS1-Type   PS2-Type   Modem   Baud  Traffic Peak Peak-Time
---------- ---------- ------- ----- ------- ---- -------------------------
WS-C5008A  none       disable  9600   0%      0% Thu Aug 10 1998, 03:22:20
 
System Name              System Location          System Contact
------------------------ ------------------------ ------------------------
Catalyst 5000            San Jose, CA             Susan x237
Console> 
 

Table 2-61 describes the fields in the show system command output.


Table 2-61: show system Command Output Fields
Field Description

PS1-Status

Status of power supply 1 (ok, fan failed, faulty, or none).

PS2-Status

Status of power supply 2 (ok, fan failed, faulty, or none).

Fan-Status

Status of the fan (ok, faulty, or other).

Temp-Alarm

Status of whether the temperature alarm is off or on.

Sys-Status

System status (ok or faulty). Corresponds to system LED status.

Uptime d, h:m:s

Amount of time in days, hours, minutes, and seconds, that the system has been up and running.

Logout

Amount of time after which an idle session is disconnected.

PS1-Type

Part number of the power supply.

PS2-Type

Part number of the redundant power supply, if present.

Modem

Status of the modem status (enable or disable).

Baud

Baud rate to which the modem is set.

Traffic

Current traffic percentage.

Peak

Peak percentage of traffic on the backplane.

Peak-Time

Time stamp when peak percentage was recorded.

System Name

System name.

System Location

System location.

System Contact

System contact information.

Related Commands

set system baud
set system contact
set system location
set system modem
set system name

show tacacs

Use the show tacacs command to display the TACACS+ or RADIUS protocol configuration.

show tacacs [noalias]

Syntax Description

noalias

(Optional) Keyword to force the display to show IP addresses, not IP aliases.

Default

This command has no default setting.

Supported Platforms

Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch

Command Type

Switch command.

Command Mode

Normal.

Example

This example shows how to display the TACACS+ or RADIUS protocol configuration:

Console> show tacacs
Login Authentication: Console Session   Telnet Session
--------------------- ----------------  ----------------
tacacs                disabled          disabled
radius                disabled          enabled(primary)
local                 enabled(primary)  enabled
 
Enable Authentication:Console Session   Telnet Session
------------------    ----------------  ----------------
tacacs                enabled(primary)  enabled(primary)
radius                disabled          disabled
local                 enabled           enabled
 
Tacacs login attempts: 3
Tacacs timeout: 5 seconds
Tacacs direct request: disabled
 
Tacacs-Server                              Status
----------------------------------------   -------
171.69.193.114                             primary
Console>
 

Table 2-62 describes the fields in the show tacacs command output.


Table 2-62: show tacacs Command Output Fields
Field Description

Login authentication

Display of the login authentication types.

Console Session

Status of whether the console session is enabled or disabled.

Telnet Session

Status of whether the telnet session is enabled or disabled.

Enable Authentication:

Display of the enable authentication types.

Tacacs login attempts

Number of failed login attempts allowed.

Tacacs timeout

Time in seconds to wait for a response from the TACACS+ server.

Tacacs direct request

Status of whether TACACS+ directed-request option is enabled or disabled.

Tacacs-Server

IP addresses or IP aliases of configured TACACS+ servers.

Status

Primary TACACS+ server.

Related Commands

set tacacs attempts
set tacacs directedrequest
set tacacs key
set tacacs server
set tacacs timeout

show test

Use the show test command to display the results of diagnostic tests.

show test [mod_num]

Syntax Description

mod_num

(Optional) Number of the module. If you do not specify a number, test statistics are given for the general system as well as for module 1.

Default

This command has no default setting.

Supported Platforms

Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch

Command Type

Switch command.

Command Mode

Normal.

Usage Guidelines

The NMP information only applies to module 1; therefore, only the display for module 1 includes the NMP status. If you specify other modules, the NMP status is not displayed.

Systems configured with Supervisor Engine IIIs do not have MII Status information displayed in the output. MII Status information is displayed for systems configured with Supervisor Engine I or II.

Examples

This example shows how to display general test results for the system and for module 1 on a Catalyst 5000 family or 2926G series switch:

Console> show test 
Environmental Status (. = Pass, F = Fail, U = Unknown)
  PS (3.3V):   .   PS (12V): .   PS (24V):   .   PS1: .     PS2: .
  Temperature: .   Fan:      .
 
Module 1 : 2-port 10/100BaseTX Supervisor
Network Management Processor (NMP) Status: (. = Pass, F = Fail, U = Unknown)
  ROM:  .   Flash-EEPROM: .   Ser-EEPROM: .   NVRAM: .   MCP Comm: . 
  EARL Status :
        NewLearnTest:         .
        IndexLearnTest:       .
        DontForwardTest:      .
        MonitorTest           .
        DontLearn:            .
        FlushPacket:          .
        ConditionalLearn:     .
        EarlLearnDiscard:     .
        EarlTrapTest:         .
 
 
LCP Diag Status for Module 1  (. = Pass, F = Fail, N = N/A)
 CPU         : .    Sprom    : .    Bootcsum : .    Archsum  : .
 RAM         : .    LTL      : .    CBL      : .    DPRAM    : .   SAMBA : .
 Saints      : .    Pkt Bufs : .    Repeater : N    FLASH    : .
 Phoenix     : . TrafficMeter: . UplinkSprom : . PhoenixSprom: .
 
  MII Status:
  Ports 1  2
  -----------
        N  N
 
 SAINT/SAGE Status :
  Ports 1  2
  -----------
        .  .
 
 PHOENIX Port Status :
  Ports 9    17   18   19   20   21   22
      INBAND A->B B->A B->C C->B A->C C->A
  ------------------------------------------
        .    .    .    .    .    .    .
 
 Packet Buffer Status :
  Ports 1  2
  -----------
        .  .
 
 PHOENIX Packet Buffer Status :
  Ports INBAND A<->B B<->C A<->C
  ------------------------------
         .     .     .     .
 
 Loopback Status [Reported by Module 1] :
  Ports  1  2  9
  --------------
         .  .  .
 
 Channel Status :
  Ports  1  2
  -----------
         .  .
 
Console>
 

This example shows how to display general test results for a Catalyst 4000 family or Catalyst 2948G switch:

Console> show test
 
Environmental Status (. = Pass, F = Fail, U = Unknown, N = Not Present)
  PS1: .    PS2: N    PS1 Fan: .    PS2 Fan: N    Fan Tray: .
  Temperature: .        Chassis Temperature: 39 degC (102 degF)
 
Module 1 : 0-port Switching Supervisor
Network Management Processor (NMP) Status: (. = Pass, F = Fail, U = Unknown)
  Control Processor Status:
    DRAM : .     EEPROM : .     FLASH : .     NVRAM : .
 
  SX1000:
    Register    : .    Network Memory : .
 
  Mgmt Port Loopback Status: .
Console> 
 

This example shows how to display general test results for module 3 on a Catalyst 4000 family or 2948G switch:

Console> show test 3
Module 3: 48 10/100 Base T port Ethernet Card
 
  (HX,CX)1000:
    Ports 1-8:.Ports 9-16:.Ports 17-24:.
    Ports 25-32:.Ports 33-40:.Ports 41-48:.
 
10/100BaseTX Loopback Status:
    Ports  1  2  3  4  5  6  7  8  9  10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
    ------------------------------------------------------------------------------
           .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .
    Ports  25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48
    ------------------------------------------------------------------------------
 

Table 2-63 describes the possible fields in the show test command output.


Table 2-63: show test Command Output Fields
Field Description

Environmental Status

Test results that apply to the general system environment.

PS (3.3V)

Test results for the 3.3V power supply.

PS (12V)

Test results for the 12V power supply.

PS (24V)

Test results for the 24V power supply.

PS1

Test results for power supply 1.

PS2

Test results for power supply 2.

Temperature

Test results for temperature.

Fan

Test results for the fan.

Module 1

Test results that apply to module 1. The module type is indicated as well.

Network Management Processor (NMP) Status

Test results that apply to the NMP on the supervisor module.

ROM

Test results for ROM.

Flash-EEPROM

Test results for the Flash EEPROM.

Ser-EEPROM

Test results for serial EEPROM.

NVRAM

Test results for the NVRAM.

EARL Status

Fields that display the EARL status information.

NewLearnTest

Test results for NewLearn test (EARL).

IndexLearnTest

Test results for IndexLearn test (EARL).

DontForwardTest

Test results for DontForward test (EARL).

MonitorTest

Test results for Monitor test (EARL).

DontLearn

Test results for DontLearn test (EARL).

FlushPacket

Test results for FlushPacket test (EARL).

ConditionalLearn

Test results for ConditionalLearn test (EARL).

EarlLearnDiscard

Test results for EarlLearnDiscard test (EARL).

EarlTrapTest

Test results for EarlTrap test (EARL).

LCP Diag Status for Module 1

Test results for the specified module.

CPU

Test results for the CPU.

Sprom

Test results for serial PROM.

Bootcsum

Test results for Boot ROM checksum.

Archsum

Test results for archive Flash checksum.

RAM

Test results for the RAM.

LTL

Test results for local-target logic.

CBL

Test results for color-blocking logic.

DPRAM

Test results for dual-port RAM.

SAMBA

Test results for SAMBA chip.

Saints

Test results for SAINT chips.

Pkt Bufs

Test results for the packet buffers.

Repeater

Test results for repeater module.

FLASH

Test results for the Flash.

Phoenix

Test results for the Phoenix.

TrafficMeter

Test results for the TrafficMeter.

UplinkSprom

Test results for the UplinkSprom.

PhoenixSprom

Test results for the Phoenix.

MII Status

Test results for MII ports.

SAINT/SAGE Status

Test results for individual SAINT/SAGE chip.

Phoenix Port Status

Test results for Phoenix ports.

Packet Buffer Status

Test results for individual packet buffer.

Phoenix Packet Buffer Status

Test results for Phoenix packet buffer.

Loopback Status

Test results for the loopback test.

Channel Status

Test results for the channel test.

This example shows how to display test results for module 10 (an FDDI module):

Console> show test 10
 
Module 10 : 2-port MM MIC FDDI
Module 10 : FDDI Module Status: (. = Pass, F = Fail, U = Unknown)
 
FDDI Control Processor (FCP) Status:
  ROM:  .   RAM:  .   Flash-EEPROM: .   Dpram: .
 
  Switch Memory Status:
  RAM:  .   Cache-SRAM: .    DmpCom: .    Loadgen: .
 
FDDI Status:
  Port A Access:   .  Port B Access:   .
  Port A Loopback: .  Port B Loopback: .
  MAC Access:      .  MAC Buffer R/W:  .
  MAC Internal LB: .  MAC External LB: .
  CAM:  . . . .
 
Data Movement Processor (DMP) Status:
  Flash-EEPROM: .   RAM: .  SRAM: . COMM: .
 
  Switch Memory Status:
  RAM: .  Cache-SRAM: .
 
FDDI Status:
  MAC Access:            .   MAC Buffer R/W:        .
  MAC Internal LB:       .   MAC External LB:       .  LoadGen:.
  FBIGA Access:          .   FBIGA->MAC Buffer R/W: .
  FBIGA->MAC TxDMA:      .   FBIGA->MAC RxDMA:      .
  FBIGA->MAC Internal LB:.   FBIGA->MAC External LB:.  LoadGen:.
 
Bus Interface Status:
  SBIGA Access:          .   SBIGA->SAGE RxDMA:     .  SBIGA<-SAGE TxDMA:.
  Biga Loop Access:      .   Biga Loop Rx:          .  Biga Loop Tx:     .
 
LCP Diag Status for Module 10  (. = Pass, F = Fail, N = N/A)
 CPU         : .    Sprom    : .    Bootcsum : .    Archsum  : N
 RAM         : .    LTL      : .    CBL      : .    DPRAM    : .   SAMBA : N
 Saints      : .    Pkt Bufs : .    Repeater : N    FLASH    : N
 
 SAINT/SAGE Status :
  Ports 1
  --------
        .
 
 Packet Buffer Status :
  Ports 1
  --------
        .
 
 Loopback Status :
  Ports 1
  --------
        .
 
Console> 
 
 
 

Table 2-64 describes the possible fields in the show test command output for an FDDI module.


Table 2-64: show test Command Output Fields (FDDI)
Field Description

Module 10

Fields that indicate subsequent test results apply to module 10. The module type is indicated as well.

FDDI Control Processor (FCP) Status

Fields that indicate FCP status.

ROM

Test results for the ROM.

RAM

Test results for the RAM.

Flash-EEPROM

Test results for the Flash EEPROM.

Dpram

Test results for the dynamic PRAM.

Switch Memory Status

Fields that indicate the switch memory status.

RAM

Test results for the RAM.

Cache-SRAM

Test results for the queue SRAM.

DmpCom

Test results for communication block.

Loadgen

Test results for MAC LoadGen test.

FDDI Status

Fields that indicate FDDI status.

Port A Access

Test results for port A PHY register test.

Port B Access

Test results for port B PHY register test.

Port A Loopback

Test results for port A PHY loopback test.

Port B Loopback

Test results for port B PHY loopback test.

MAC Access

Test results for MAC register test.

MAC Buffer R/W

Test results for MAC buffer memory test.

MAC Internal LB

Test results for MAC internal loopback test.

MAC External LB

Test results for MAC external loopback test.

CAM

Test results for the CAM.

Data Movement Processor (DMP) Status

Fields that indicate the DMP status.

Flash-EEPROM

Test results for the Flash EEPROM.

RAM

Test results for the RAM.

SRAM

Test results for the SRAM test.

COMM

Test results for communication block.

Switch Memory Status

Fields that indicate switch memory status.

RAM

Test results for the RAM.

Cache-SRAM

Test results for the queue SRAM.

FDDI Status

Fields that indicate FDDI status.

MAC Access

Test results for MAC register test.

MAC Buffer R/W

Test results for MAC buffer memory test.

MAC Internal LB

Test results for MAC internal loopback test.

MAC External LB

Test results for MAC external loopback test.

LoadGen

Test results for MAC LoadGen test.

FBIGA Access

Test results for FBIGA register test.

FBIGA->MAC Buffer R/W

Test results for FBIGA buffer memory test.

FBIGA->MAC TxDMA

Test results for FBIGA transmit test.

FBIGA->MAC RxDMA

Test results for FBIGA receive test

FBIGA->MAC Internal LB

Test results for FBIGA internal loopback test.

FBIGA->MAC External LB

Test results for FBIGA external loopback test.

LoadGen

Test results for FBIGA LoadGen test.

Bus Interface Status

Fields that indicate bus interface status.



hometocprevnextglossaryfeedbacksearchhelp
Posted: Mon Oct 4 14:03:03 PDT 1999
Copyright 1989-1999©Cisco Systems Inc.