Use the show rif command to display RIF information.
show rif [vlan_num]
vlan_num | (Optional) Number of the VLAN that you want to view RIF information. |
This command has no default setting.
Catalyst 5000 family switches
Switch command.
Normal.
This example shows how to display RIF information for the system and for a VLAN:
Console> show rifMAC VLAN RIF-------------------- -------- --------------------00:00:30:e2:cf:00 on 401 via 0610.001a.002000:05:77:01:bc:4a on 1020 via 0690.00d1.00e200:05:77:01:bc:4b on 1020 via 0690.00d1.00e200:05:77:01:bc:48 on 1020 via 0690.00d1.00e2
This example shows how to display RIF information for a VLAN:
Console>show rif 401MAC VLAN RIF-------------------- -------- --------------------00:00:30:e2:cf:00 on 401 via 0610.001a.0020Console>
Use the show rsmautostate command to display the current status of line protocol state determination of the RSMs caused by Catalyst 5000 family and 2926G series switch port state change.
show rsmautostate mod_num
mod_num | Number of the module. |
This command has no default setting.
Catalyst 5000 family switches
Switch command.
Normal.
This example shows how to display the current status of RSM line protocol state determination:
Console> show rsmautostate RSM Auto port state: enabled Console>
Use the show snmp command to display SNMP information.
show snmp [noalias]
noalias | (Optional) Keyword that forces the display to show IP address, not IP aliases. |
This command has no default setting.
Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch
Switch command.
Normal.
This example shows how to display SNMP information:
Console> show snmp RMON: Enabled Traps Enabled: Chassis Port Traps Enabled: None Community-Access Community-String ---------------- -------------------- read-only public read-write private read-write-all secret Trap-Rec-Address Trap-Rec-Community ---------------------------------------- -------------------- 192.122.173.42 public Console>
Console> show snmp RMON: Enabled Traps Enabled: Chassis Port Traps Enabled: None Community-Access Community-String ---------------- -------------------- read-only public read-write private read-write-all secret Trap-Rec-Address Trap-Rec-Community ---------------------------------------- -------------------- 192.122.173.42 public Extended Rmon: Disabled Extended RMON Netflow: Disabled Extended RMON Vlanmode: Disabled Extended RMON Vlanagent: Disabled
Table 2-55 describes the possible fields (depending on the port type queried) in the show snmp command output.
| Field | Description |
|---|---|
RMON | Status of whether RMON is enabled or disabled. |
Traps Enabled | Trap types that are enabled. |
Port Traps Enabled | Set of ports whose linkup/linkdown trap is enabled. |
Community-Access | Configured SNMP communities. |
Community-String | SNMP community strings associated with each SNMP community. |
Trap-Rec-Address | IP address or IP alias of trap receiver hosts. |
Trap-Rec-Community | SNMP community string used for trap messages to the trap receiver. |
Extended Rmon | Status of whether extended RMON is enabled or disabled. |
Extended RMON Netflow | Status of whether Netflow Monitor option is enabled or disabled. |
Extended RMON Vlanmode | Status of whether VLAN Monitor option is enabled or disabled. |
Extended RMON Vlanagent | Status of whether VLANagent option is enabled or disabled. |
Use the show span command to display information about the current SPAN configuration:
show spanThis command has no keywords or arguments.
This command has no default setting.
Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch
Switch command.
Normal.
SPAN in the context of a single module is the only possible configuration for Token Ring modules.
This example shows how to display SPAN information for the switch:
Console> (enable) show span Destination: Port 4/1 Admin Source: Port 3/1-6 Oper Source: Port 3/1-5 Direction: transmit/receive Incoming Packets: enabled Console> (enable)
Table 2-56 describes the fields in the show span command output.
| Field | Description |
|---|---|
Destination | Destination port for SPAN information. |
Admin Source | Source port or VLAN for SPAN information. |
Oper Source | Operator port or VLAN for SPAN information. |
Direction | Status of whether transmit, receive, or transmit/receive information is monitored. |
Incoming Packets | Status of whether reception of normal incoming packets on the SPAN destination port is enabled or disabled. |
Use the show spantree command to display spanning-tree information for a VLAN.
show spantree [vlan | mod_num/port_num] [active]
vlan | (Optional) Number of the VLAN. If the VLAN number is not specified, the default is VLAN 1. |
mod_num | (Optional) Number of the module. |
port_num | (Optional) Number of the port on the module. |
active | (Optional) Keyword to display only the active ports. |
This command has no default setting.
Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch
Switch command.
Normal.
The Catalyst 2948G switch is a fixed configuration switch. All ports are located on module 2; for this reason, if you enter mod_num/port_num 1/N, an error message will be displayed.
This example shows how to display the spanning-tree configuration for VLAN 1005:
Console>show spantree 1005VLAN 1005Spanning tree enabled Designated Root 00-40-0b-8f-8b-ec Designated Root Priority 32768 Designated Root Cost 0 Designated Root Port 1/0 Root Max Age 6 sec Hello Time 2 sec Forward Delay 4 sec Bridge ID MAC ADDR 00-40-0b-8f-8b-ec Bridge ID Priority 32768 Bridge Max Age 6 sec Hello Time 2 sec Forward Delay 4 sec Port,Vlan Vlan Port-State Cost Priority Fast-Start Group-method --------- ---- ------------- ----- -------- ---------- ------------ 1003 1005 inactive 80 32 disabled Console>
This example shows how to display only the active ports:
Console> show spantree active
VLAN 1
Spanning tree enabled
Spanning tree type ieee
Designated Root 00-60-70-4c-70-00
Designated Root Priority 32768
Designated Root Cost 19
Designated Root Port 1/1
Root Max Age 20 sec Hello Time 2 sec Forward Delay 15 sec
Bridge ID MAC ADDR 00-e0-1e-9b-2e-00
Bridge ID Priority 32768
Bridge Max Age 20 sec Hello Time 2 sec Forward Delay 15 sec
Port Vlan Port-State Cost Priority Fast-Start Group-Method
--------- ---- ------------- ----- -------- ---------- ------------
1/1 1 forwarding 19 32 disabled
3/1-2 1 forwarding 19 32 disabled redundancy
Table 2-57 describes the possible fields in the show spantree command output.
| Field | Description |
|---|---|
VLAN | VLAN for which spanning-tree information is shown. |
Spanning tree | Status of whether Spanning-Tree Protocol is enabled or disabled. |
Designated Root | MAC address of the designated spanning-tree root bridge. |
Designated Root Priority | Priority of the designated root bridge. |
Designated Root Cost | Total path cost to reach the root. |
Designated Root Port | Port through which the root bridge can be reached (shown only on nonroot bridges). |
Root Max Age | Amount of time a BPDU packet should be considered valid. |
Hello Time | Number of times the root bridge sends BPDUs. |
Forward Delay | Amount of time the port spends in listening or learning mode. |
Bridge ID MAC ADDR | Bridge MAC address. |
Bridge ID Priority | Bridge priority. |
Bridge Max Age | Bridge maximum age. |
Hello Time | Amount of time the bridge sends BPDUs. |
Forward Delay | Amount of time the bridge spends in listening or learning mode. |
Port | Port number. |
Vlan | VLAN to which the port belongs. |
Port-State | Spanning-tree port state (disabled, inactive, not-connected, blocking, listening, learning, forwarding, bridging, or type-pvid-inconsistent). |
Cost | Cost associated with the port. |
Priority | Priority associated with the port. |
Fast-Start | Status of whether the port is configured to use the fast-start feature. |
Group-Method | Method of how the multiple ports are treated (redundancy=dual PHY and FDDI; repeater=RSM; channel=Fast EtherChannel). |
Use the show spantree backbonefast command to display whether the spanning-tree Backbone Fast Convergence feature is enabled.
show spantree backbonefastThis command has no arguments or keywords.
This command has no default setting.
Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch
Switch command.
Normal.
This example shows how to display whether the spanning-tree Backbone Fast Convergence feature is enabled:
Console> show spantree backbonefast Backbonefast is enabled. Console>
Use the show spantree blockedports command to display only the blocked ports.
show spantree blockedports [vlan_num]
vlan_num | (Optional) Number of the VLAN. |
This command has no default setting.
Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch
Switch command.
Normal.
If you do not specify a VLAN number, all blocked ports in the system are displayed.
This example shows how to display the blocked ports for VLAN 1002:
Console> show spantree blockedports 1002 Number of blocked ports (segments) in VLAN 1002 : 0 Console>
Use the show spantree portstate command to determine the current spanning-tree state of a Token Ring port within a spanning tree.
show spantree portstate [trcrf ]
trcrf | (Optional) Token Ring concentrator relay function statistical information. |
This command has no default setting.
Catalyst 5000 family switches
Switch command.
Normal.
This example shows how to display the current spanning-tree state of a Token Ring port within a spanning tree:
Console> show spantree portstate 1003 Port,Vlan Vlan Port-State Cost Priority Fast-Start Group-method --------- ---- ------------- ----- -------- ---------- ------------ 1003 1005 inactive 80 4 disabled * = portstate set by user configuration Console>
Use the show spantree portvlancost command to show the path cost for the VLANs on a port.
show spantree portvlancost mod_num/port_num
mod_num | Number of the module. |
port_num | Number of the port. |
This command has no default setting.
Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch
Switch command.
Normal.
The Catalyst 2948G switch is a fixed configuration switch. All ports are located on module 2; for this reason, if you enter mod_num/port_num 1/N, an error message will be displayed.
This example shows how to display the path cost for the VLANs on port 2/12:
Console> show spantree portvlancost 2/12 Port 2/12 VLANs 1-1005 have path cost 19. Console>
show spantree
set spantree portvlancost
Use the show spantree statistics command to show spanning-tree statistical information.
show spantree statistics mod_num/port_num [vlan]
mod_num | Number of the module. |
port_num | Number of the port. |
vlan | (Optional) Number of the VLAN. |
trcrf | Number of the Token Ring concentrator relay function VLAN. |
trbrf | Number of the Token Ring bridge relay function VLAN. |
This command has no default setting.
Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch
Switch command.
Normal.
The trcrf and trbrf arguments are not supported by the Catalyst 4000 family and 2948G switches.
The Catalyst 2948G switch is a fixed configuration switch. All ports are located on module 2; for this reason, if you enter mod_num/port_num 1/N, an error message will be displayed.
This example shows how to display Token Ring concentrator relay function statistical information:
Console> (enable) show spantree statistics 1003 1005
TR CRF 1003, TR BRF 1005
SpanningTree enabled for vlanNo = 1005
BPDU-related parameters
port spanning tree enabled
state disabled
port_id 0xcccf
port number 0x7eb
path cost 80
message age (port/VLAN) 0(10)
designated_root 00-10-2f-52-eb-ec
designated_cost 0
designated_bridge 00-10-2f-52-eb-ec
designated_port 0xcccf
top_change_ack FALSE
config_pending FALSE
port_inconsistencynone
PORT based information & statistics
config bpdu's xmitted (port/VLAN) 0(0)
config bpdu's received (port/VLAN) 0(0)
tcn bpdu's xmitted (port/VLAN) 0(0)
tcn bpdu's received (port/VLAN) 0(0)
forward trans count 0
scp failure count0
Status of Port Timers
forward delay timer INACTIVE
forward delay timer value 0
message age timer INACTIVE
message age timer value 0
topology change timer INACTIVE
topology change timer value 0
hold timer INACTIVE
hold timer value 0
delay root port timer INACTIVE
delay root port timer value 0
VLAN based information & statistics
spanningtree type ibm
spanningtree multicast address c0-00-00-00-01-00
bridge priority 32768
bridge mac address 00-10-2f-52-eb-ec
bridge hello time 2 sec
bridge forward delay 4 sec
topology change initiator: 1/0
topology change FALSE
topology change time 14
topology change detected FALSE
topology change count 0
topology change last recvd. from 00-00-00-00-00-00
Other port-specific info
dynamic max age transitions 0
port bpdu ok count 0
msg age expiry count 0
link loading 1
bpdu in processing FALSE
num of similar bpdus to process 0
next state 0
src mac count: 0
total src mac count 0
curr_src_mac 00-00-00-00-00-00
next_src_mac 00-00-00-00-00-00
channel_src_mac 00-00-00-00-00-00
channel src count 0
channel ok count 0
Console> (enable)
Table 2-58 describes the possible fields in the show spantree statistics command output.
| Field | Description |
|---|---|
| BPDU-related parameters | |
port spanning tree | Status of whether Spanning-Tree Protocol is enabled or disabled on the port. |
state | Spanning-tree port state (Disabled, Listening, Learning, Forwarding, or Blocking). |
port_id | Port identifier of the associated port. |
port number | Port number. |
path cost | Contribution of the path through this root port. This applies to the total path cost to the root for this bridge. |
message age (port/VLAN) | Age of the received protocol information recorded for a port and the value of the Max Age parameter (shown in parenthesis) recorded by the switch. |
designated_root | MAC address of the designated spanning-tree root bridge. |
designated_cost | Cost of the path to the root offered by the designated port on the LAN to which this port is attached. |
designated_bridge | Bridge identifier of the bridge assumed to be the Designated Bridge for the LAN associated with the port. |
designated_port | Port identifier of the Bridge Port assumed to be the Designated Port for the LAN associated with the port. |
top_change_ack | Value of the Topology Change Acknowledgment flag in the next configured BPDU to be transmitted on the associated port. The flag is set in reply to a Topology Change Notification BPDU. |
config_pending | Boolean parameter set to record that a configured BPDU should be transmitted on expiration of the hold timer for the associated port. |
port_inconsistency | Status of whether the port is in an inconsistent (PVID or port type) state or not. |
| PORT-based information and statistics | |
config bpdu's xmitted (port/VLAN) | Number of BPDUs transmitted from the port. The number in parentheses is the number of configured BPDUs transmitted by the switch for this instance of spanning-tree. |
config bpdu's received (port/VLAN) | Number of BPDUs received by this port. The number in parentheses is the number of configured BPDUs received by the switch for this instance of spanning-tree. |
tcn bpdu's xmitted (port/VLAN) | Number of TCN BDPUs transmitted on this port. |
tcn bpdu's received (port/VLAN) | Number of TCN BPDUs received on this port. |
forward trans count | Number of times the port state transitioned to FORWARDing state. |
scp failure count | Number of SCP failures. |
| Status of Port Timers | |
forward delay timer | Status of the forward delay timer. This timer monitors the time spent by a port in the Listening and Learning States. |
forward delay timer value | Current value of the forward delay timer. |
message age timer | Status of the message age timer. This timer measures the age of the received protocol information recorded for a port. |
message age timer value | Current value of the message age timer. |
topology change timer | Status of the topology change timer. This timer determines the time period in which configured BPDUs are transmitted with the topology change flag set by the bridge when it is root following the detection of a topology change. |
topology change timer value | Current value of the topology change timer. |
hold timer | Status of the hold timer. This timer ensures that configured BPDUs are not transmitted too frequently through any bridge port. |
hold timer value | Current value of the hold timer. |
delay root port timer | Status of the delay root port timer. This timer enables fast convergence on linkup when the UplinkFast feature is enabled. |
delay root port timer value | Current value of the delay root port timer. |
| VLAN-based information and statistics | |
spanningtree type | Type of spanning tree (IEEE, IBM, CISCO). |
spanningtree multicast address | Destination address used to send out configured BPDUs on a bridge port. |
bridge priority | Part of the bridge identifier and is taken as the most significant part bridge ID comparisons. |
bridge mac address | Bridge Mac address. |
bridge hello time | Value of the Hello Time parameter when the bridge is the root or is attempting to become the root. |
bridge forward delay | Value of the Forward Delay parameter when the bridge is the root or is attempting to become the root. |
topology change | Time the last topology change occurred. |
topology change initiator: | Number of the port that caused the topology change. |
topology change | Number of times configured BPDUs have been transmitted by the bridge on the LANs for which the bridge is the designated bridge. |
topology change time | Time period for which BPDUs are transmitted with the topology change flag set by the bridge when it is the root following the detection of a topology change. It is equal to the sum of the bridge's Max Age and Forward Delay parameters. |
topology change detected | Number of topology changes that have been detected by or notified to the bridge. |
topology change count | Number of times the topology change has occurred. |
topology change last recvd. from | MAC address of the bridge that transmitted the last TCN BPDU. |
| Other port-specific info | |
dynamic max age transitions | Number of dynamic max age transitions. |
port bpdu ok count | Number of reported port BPDU counts. |
msg age expiry count | Number of message age expires. |
link loading | Status of whether the link is oversubscribed. |
bpdu in processing | Status of whether the BPDU is under processing. |
num of similar bpdus to process | Number of similar BPDUs to process that are received on a specific port. |
received_inferior_bpdu | Status of whether the port received an inferior BPDU or in response to an RLQ BPDU. |
next state | Port state before it is actually set by spanning tree, to facilitate other tasks in using the new value. |
src mac count: | Number of BPDUs with the same source MAC address. |
total src mac count | Number of BPDUs with all the source MAC addresses. |
curr_src_mac | Source MAC address of the configured BPDU received on a particular port. |
next_src_mac | MAC address from the different source. |
channel_src_mac | Source MAC address of the channel port. It is used to detect channel misconfiguration and avoid spanning-tree loops. |
channel src count | Number of times channel_src_mac gets changed and if the limit is exceeded, a channel misconfiguration is detected. |
channel ok count | Boolean flag which records the channel status. |
show spantree
clear spantree statistics
Use the show spantree summary command to display a summary of spanning-tree information.
show spantree summaryThis command has no arguments or keywords.
This command has no default setting.
Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch
Switch command.
Normal.
This example shows how to display a summary of spanning-tree information:
Console> show spantree summary
Summary of connected spanning tree ports by vlan
Uplinkfast disabled for bridge.
Backbonefast enabled for bridge.
Vlan Blocking Listening Learning Forwarding STP Active
----- -------- --------- -------- ---------- ----------
1 0 0 0 1 1
Blocking Listening Learning Forwarding STP Active
----- -------- --------- -------- ---------- ----------
Total 0 0 0 1 1
BackboneFast statistics
-----------------------
Number of inferior BPDUs received (all VLANs) : 0
Number of RLQ req PDUs received (all VLANs) : 0
Number of RLQ res PDUs received (all VLANs) : 0
Number of RLQ req PDUs transmitted (all VLANs) : 0
Number of RLQ res PDUs transmitted (all VLANs) : 0
Console>
Use the show spantree uplinkfast command to show the uplinkfast settings.
show spantree uplinkfastThis command has no arguments or keywords.
This command has no default setting.
Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch
Switch command.
Normal.
This example shows how to display the uplinkfast settings:
Console> show spantree uplinkfast VLAN port list ------------------------------------------------ 1-20 1/1(fwd),1/2-1/5 21-50 1/9(fwd), 1/6-1/8, 1/10-1/12 51-100 2/1(fwd), 2/12 Console>
show spantree
set spantree uplinkfast
clear spantree uplinkfast
Use the show standbyports command to display the current status of the standby ports feature. The standby ports feature allows the ports on the standby supervisor engine module to pass traffic. If this feature is disabled, the ports are in standby mode.
show standbyportsThis command has no arguments or keywords.
This command has no default setting.
Catalyst 5000 family switches
Normal.
Switch command.
This example shows how to display the current status of the standby ports feature:
Console> show standbyports Standby ports feature enabled Console>
Use the show station controltable command to display a collection of statistics and status information associated with each Token Ring station on the local ring. In addition, this command provides status information for each ring being monitored.
show station controltable [mod_num[/port_num]]
mod_num | (Optional) Number of the module. |
/port_num | (Optional) Number of the port on the module. |
This command has no default setting.
Catalyst 5000 family switches
Switch command.
Normal.
This command is only supported on Token Ring modules.
This example shows how to display a collection of statistics and status information associated with each Token Ring station on Token Ring module 3:
Console> show station controltable 3 Port TableSize ActiveStation RingState ----- ----------------- ----------------- ----------------- 3/1 0 0 Normal Operation 3/2 0 0 Normal Operation 3/3 0 0 Normal Operation 3/4 0 0 Normal Operation 3/5 0 0 Normal Operation 3/6 0 0 Normal Operation 3/7 0 0 Normal Operation 3/8 0 0 Normal Operation 3/9 0 0 Normal Operation 3/10 0 0 Normal Operation 3/11 0 0 Normal Operation 3/12 0 0 Normal Operation 3/13 0 0 Normal Operation 3/14 0 0 Normal Operation 3/15 0 2 Normal Operation 3/16 0 0 Normal Operation Port BeaconSender BeaconNAUN OrderChanges ----- ----------------- ----------------- ----------------- 3/1 00:00:00:00:00:00 00:00:00:00:00:00 0 3/2 00:00:00:00:00:00 00:00:00:00:00:00 0 3/3 00:00:00:00:00:00 00:00:00:00:00:00 0 3/4 00:00:00:00:00:00 00:00:00:00:00:00 0 3/5 00:00:00:00:00:00 00:00:00:00:00:00 0 3/6 00:00:00:00:00:00 00:00:00:00:00:00 0 3/7 00:00:00:00:00:00 00:00:00:00:00:00 0 3/8 00:00:00:00:00:00 00:00:00:00:00:00 0 3/9 00:00:00:00:00:00 00:00:00:00:00:00 0 3/10 00:00:00:00:00:00 00:00:00:00:00:00 0 3/11 00:00:00:00:00:00 00:00:00:00:00:00 0 3/12 00:00:00:00:00:00 00:00:00:00:00:00 0 3/13 00:00:00:00:00:00 00:00:00:00:00:00 0 3/14 00:00:00:00:00:00 00:00:00:00:00:00 0 3/15 00:00:00:00:00:00 00:00:00:00:00:00 1 3/16 00:00:00:00:00:00 00:00:00:00:00:00 0 Console>
Table 2-59 describes the fields in the show station controltable command output.
| Field | Description |
Port | Module and port number. |
TableSize | Number of Token Ring station entries in the table associated with this port. |
ActiveStation | Number of active Token Ring station entries in the table associated with this port. |
RingState | Current status of the ring. |
BeaconSender | Address of the sender of the last beacon frame received on this ring. If no beacon frames have been received, this object shall be equal to six octets of zero. |
BeaconNAUN | Address of the nearest upstream neighbor in the last beacon frame received on this ring. If no beacon frames have been received, this object shall be equal to six octets |
OrderChanges | Number of add and delete events in the table associated with this port. |
show counters
show station ordertable
Use the show station ordertable command to display a listing of the order of stations on the monitored rings.
show station ordertable [mod_num[/port_num]]
mod_num | (Optional) Number of the module. |
/port_num | (Optional) Number of the port on the module. |
This command has no default setting.
Catalyst 5000 family switches
Switch command.
Normal.
This example shows how to display a listing of the order of stations on the Token Ring module 3:
Console> show station ordertable 3
Port OrderIndex Address
----- --------------- -----------------
3/15 1 00:05:77:05:40:63
2 00:00:30:cf:a0:98
Console>
Table 2-60 describes the fields in the show station ordertable command output.
| Field | Description |
Port | Module and port number. |
OrderIndex | Location of the station with respect to other stations on the ring. |
Address | Physical address of the station. |
show counters
show station controltable
Use the show summertime command to display the current status of the summertime feature.
show summertimeThis command has no arguments or keywords.
This command has no default setting.
Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch
Switch command.
Normal.
This example shows how to display the current status of the summertime feature:
Console> show summertime Summertime is enabled and set to 'pst' Console>
The output indicates whether the feature is enabled or disabled and the time zone configured for use with the feature.
Use the show system command to display system information.
show systemThis command has no keywords or arguments.
This command has no default setting.
Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch
Switch command.
Normal.
In a Token Ring module, the values shown for Traffic and Peak are the average of three switching buses.
This example shows the system status and other information:
Console> show system PS1-Status PS2-Status Fan-Status Temp-Alarm Sys-Status Uptime d,h:m:s Logout ---------- ---------- ---------- ---------- ---------- -------------- --------- ok none ok off ok 3,02:08:53 20 min PS1-Type PS2-Type Modem Baud Traffic Peak Peak-Time ---------- ---------- ------- ----- ------- ---- ------------------------- WS-C5008A none disable 9600 0% 0% Thu Aug 10 1998, 03:22:20 System Name System Location System Contact ------------------------ ------------------------ ------------------------ Catalyst 5000 San Jose, CA Susan x237 Console>
Table 2-61 describes the fields in the show system command output.
| Field | Description |
|---|---|
PS1-Status | Status of power supply 1 (ok, fan failed, faulty, or none). |
PS2-Status | Status of power supply 2 (ok, fan failed, faulty, or none). |
Fan-Status | Status of the fan (ok, faulty, or other). |
Temp-Alarm | Status of whether the temperature alarm is off or on. |
Sys-Status | System status (ok or faulty). Corresponds to system LED status. |
Uptime d, h:m:s | Amount of time in days, hours, minutes, and seconds, that the system has been up and running. |
Logout | Amount of time after which an idle session is disconnected. |
PS1-Type | Part number of the power supply. |
PS2-Type | Part number of the redundant power supply, if present. |
Modem | Status of the modem status (enable or disable). |
Baud | Baud rate to which the modem is set. |
Traffic | Current traffic percentage. |
Peak | Peak percentage of traffic on the backplane. |
Peak-Time | Time stamp when peak percentage was recorded. |
System Name | System name. |
System Location | System location. |
System Contact | System contact information. |
set system baud
set system contact
set system location
set system modem
set system name
Use the show tacacs command to display the TACACS+ or RADIUS protocol configuration.
show tacacs [noalias]
noalias | (Optional) Keyword to force the display to show IP addresses, not IP aliases. |
This command has no default setting.
Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch
Switch command.
Normal.
This example shows how to display the TACACS+ or RADIUS protocol configuration:
Console> show tacacs Login Authentication: Console Session Telnet Session --------------------- ---------------- ---------------- tacacs disabled disabled radius disabled enabled(primary) local enabled(primary) enabled Enable Authentication:Console Session Telnet Session ------------------ ---------------- ---------------- tacacs enabled(primary) enabled(primary) radius disabled disabled local enabled enabled Tacacs login attempts: 3 Tacacs timeout: 5 seconds Tacacs direct request: disabled Tacacs-Server Status ---------------------------------------- -------171.69.193.114 primaryConsole>
Table 2-62 describes the fields in the show tacacs command output.
| Field | Description |
|---|---|
Login authentication | Display of the login authentication types. |
Console Session | Status of whether the console session is enabled or disabled. |
Telnet Session | Status of whether the telnet session is enabled or disabled. |
Enable Authentication: | Display of the enable authentication types. |
Tacacs login attempts | Number of failed login attempts allowed. |
Tacacs timeout | Time in seconds to wait for a response from the TACACS+ server. |
Tacacs direct request | Status of whether TACACS+ directed-request option is enabled or disabled. |
Tacacs-Server | IP addresses or IP aliases of configured TACACS+ servers. |
Status | Primary TACACS+ server. |
set tacacs attempts
set tacacs directedrequest
set tacacs key
set tacacs server
set tacacs timeout
Use the show test command to display the results of diagnostic tests.
show test [mod_num]
mod_num | (Optional) Number of the module. If you do not specify a number, test statistics are given for the general system as well as for module 1. |
This command has no default setting.
Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch
Switch command.
Normal.
The NMP information only applies to module 1; therefore, only the display for module 1 includes the NMP status. If you specify other modules, the NMP status is not displayed.
Systems configured with Supervisor Engine IIIs do not have MII Status information displayed in the output. MII Status information is displayed for systems configured with Supervisor Engine I or II.
This example shows how to display general test results for the system and for module 1 on a Catalyst 5000 family or 2926G series switch:
Console> show testEnvironmental Status (. = Pass, F = Fail, U = Unknown)PS (3.3V): . PS (12V): . PS (24V): . PS1: . PS2: .Temperature: . Fan: .Module 1 : 2-port 10/100BaseTX SupervisorNetwork Management Processor (NMP) Status: (. = Pass, F = Fail, U = Unknown)ROM: . Flash-EEPROM: . Ser-EEPROM: . NVRAM: . MCP Comm: .EARL Status :NewLearnTest: .IndexLearnTest: .DontForwardTest: .MonitorTest .DontLearn: .FlushPacket: .ConditionalLearn: .EarlLearnDiscard: .EarlTrapTest: .LCP Diag Status for Module 1 (. = Pass, F = Fail, N = N/A)CPU : . Sprom : . Bootcsum : . Archsum : .RAM : . LTL : . CBL : . DPRAM : . SAMBA : .Saints : . Pkt Bufs : . Repeater : N FLASH : .Phoenix : . TrafficMeter: . UplinkSprom : . PhoenixSprom: .MII Status:Ports 1 2-----------N NSAINT/SAGE Status :Ports 1 2-----------. .PHOENIX Port Status :Ports 9 17 18 19 20 21 22INBAND A->B B->A B->C C->B A->C C->A------------------------------------------. . . . . . .Packet Buffer Status :Ports 1 2-----------. .PHOENIX Packet Buffer Status :Ports INBAND A<->B B<->C A<->C------------------------------. . . .Loopback Status [Reported by Module 1] :Ports 1 2 9--------------. . .Channel Status :Ports 1 2-----------. .Console>
This example shows how to display general test results for a Catalyst 4000 family or Catalyst 2948G switch:
Console> show testEnvironmental Status (. = Pass, F = Fail, U = Unknown, N = Not Present)PS1: . PS2: N PS1 Fan: . PS2 Fan: N Fan Tray: .Temperature: . Chassis Temperature: 39 degC (102 degF)Module 1 : 0-port Switching SupervisorNetwork Management Processor (NMP) Status: (. = Pass, F = Fail, U = Unknown)Control Processor Status:DRAM : . EEPROM : . FLASH : . NVRAM : .SX1000:Register : . Network Memory : .Mgmt Port Loopback Status: .Console>
This example shows how to display general test results for module 3 on a Catalyst 4000 family or 2948G switch:
Console> show test 3
Module 3: 48 10/100 Base T port Ethernet Card
(HX,CX)1000:
Ports 1-8:.Ports 9-16:.Ports 17-24:.
Ports 25-32:.Ports 33-40:.Ports 41-48:.
10/100BaseTX Loopback Status:
Ports 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
------------------------------------------------------------------------------
. . . . . . . . . . . . . . . . . . . . . . . .
Ports 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48
------------------------------------------------------------------------------
Table 2-63 describes the possible fields in the show test command output.
| Field | Description |
|---|---|
Environmental Status | Test results that apply to the general system environment. |
PS (3.3V) | Test results for the 3.3V power supply. |
PS (12V) | Test results for the 12V power supply. |
PS (24V) | Test results for the 24V power supply. |
PS1 | Test results for power supply 1. |
PS2 | Test results for power supply 2. |
Temperature | Test results for temperature. |
Fan | Test results for the fan. |
Module 1 | Test results that apply to module 1. The module type is indicated as well. |
Network Management Processor (NMP) Status | Test results that apply to the NMP on the supervisor module. |
ROM | Test results for ROM. |
Flash-EEPROM | Test results for the Flash EEPROM. |
Ser-EEPROM | Test results for serial EEPROM. |
NVRAM | Test results for the NVRAM. |
EARL Status | Fields that display the EARL status information. |
NewLearnTest | Test results for NewLearn test (EARL). |
IndexLearnTest | Test results for IndexLearn test (EARL). |
DontForwardTest | Test results for DontForward test (EARL). |
MonitorTest | Test results for Monitor test (EARL). |
DontLearn | Test results for DontLearn test (EARL). |
FlushPacket | Test results for FlushPacket test (EARL). |
ConditionalLearn | Test results for ConditionalLearn test (EARL). |
EarlLearnDiscard | Test results for EarlLearnDiscard test (EARL). |
EarlTrapTest | Test results for EarlTrap test (EARL). |
LCP Diag Status for Module 1 | Test results for the specified module. |
CPU | Test results for the CPU. |
Sprom | Test results for serial PROM. |
Bootcsum | Test results for Boot ROM checksum. |
Archsum | Test results for archive Flash checksum. |
RAM | Test results for the RAM. |
LTL | Test results for local-target logic. |
CBL | Test results for color-blocking logic. |
DPRAM | Test results for dual-port RAM. |
SAMBA | Test results for SAMBA chip. |
Saints | Test results for SAINT chips. |
Pkt Bufs | Test results for the packet buffers. |
Repeater | Test results for repeater module. |
FLASH | Test results for the Flash. |
Phoenix | Test results for the Phoenix. |
TrafficMeter | Test results for the TrafficMeter. |
UplinkSprom | Test results for the UplinkSprom. |
PhoenixSprom | Test results for the Phoenix. |
MII Status | Test results for MII ports. |
SAINT/SAGE Status | Test results for individual SAINT/SAGE chip. |
Phoenix Port Status | Test results for Phoenix ports. |
Packet Buffer Status | Test results for individual packet buffer. |
Phoenix Packet Buffer Status | Test results for Phoenix packet buffer. |
Loopback Status | Test results for the loopback test. |
Channel Status | Test results for the channel test. |
This example shows how to display test results for module 10 (an FDDI module):
Console> show test 10
Module 10 : 2-port MM MIC FDDI
Module 10 : FDDI Module Status: (. = Pass, F = Fail, U = Unknown)
FDDI Control Processor (FCP) Status:
ROM: . RAM: . Flash-EEPROM: . Dpram: .
Switch Memory Status:
RAM: . Cache-SRAM: . DmpCom: . Loadgen: .
FDDI Status:
Port A Access: . Port B Access: .
Port A Loopback: . Port B Loopback: .
MAC Access: . MAC Buffer R/W: .
MAC Internal LB: . MAC External LB: .
CAM: . . . .
Data Movement Processor (DMP) Status:
Flash-EEPROM: . RAM: . SRAM: . COMM: .
Switch Memory Status:
RAM: . Cache-SRAM: .
FDDI Status:
MAC Access: . MAC Buffer R/W: .
MAC Internal LB: . MAC External LB: . LoadGen:.
FBIGA Access: . FBIGA->MAC Buffer R/W: .
FBIGA->MAC TxDMA: . FBIGA->MAC RxDMA: .
FBIGA->MAC Internal LB:. FBIGA->MAC External LB:. LoadGen:.
Bus Interface Status:
SBIGA Access: . SBIGA->SAGE RxDMA: . SBIGA<-SAGE TxDMA:.
Biga Loop Access: . Biga Loop Rx: . Biga Loop Tx: .
LCP Diag Status for Module 10 (. = Pass, F = Fail, N = N/A)
CPU : . Sprom : . Bootcsum : . Archsum : N
RAM : . LTL : . CBL : . DPRAM : . SAMBA : N
Saints : . Pkt Bufs : . Repeater : N FLASH : N
SAINT/SAGE Status :
Ports 1
--------
.
Packet Buffer Status :
Ports 1
--------
.
Loopback Status :
Ports 1
--------
.
Console>
Table 2-64 describes the possible fields in the show test command output for an FDDI module.
| Field | Description |
|---|---|
Module 10 | Fields that indicate subsequent test results apply to module 10. The module type is indicated as well. |
FDDI Control Processor (FCP) Status | Fields that indicate FCP status. |
ROM | Test results for the ROM. |
RAM | Test results for the RAM. |
Flash-EEPROM | Test results for the Flash EEPROM. |
Dpram | Test results for the dynamic PRAM. |
Switch Memory Status | Fields that indicate the switch memory status. |
RAM | Test results for the RAM. |
Cache-SRAM | Test results for the queue SRAM. |
DmpCom | Test results for communication block. |
Loadgen | Test results for MAC LoadGen test. |
FDDI Status | Fields that indicate FDDI status. |
Port A Access | Test results for port A PHY register test. |
Port B Access | Test results for port B PHY register test. |
Port A Loopback | Test results for port A PHY loopback test. |
Port B Loopback | Test results for port B PHY loopback test. |
MAC Access | Test results for MAC register test. |
MAC Buffer R/W | Test results for MAC buffer memory test. |
MAC Internal LB | Test results for MAC internal loopback test. |
MAC External LB | Test results for MAC external loopback test. |
CAM | Test results for the CAM. |
Data Movement Processor (DMP) Status | Fields that indicate the DMP status. |
Flash-EEPROM | Test results for the Flash EEPROM. |
RAM | Test results for the RAM. |
SRAM | Test results for the SRAM test. |
COMM | Test results for communication block. |
Switch Memory Status | Fields that indicate switch memory status. |
RAM | Test results for the RAM. |
Cache-SRAM | Test results for the queue SRAM. |
FDDI Status | Fields that indicate FDDI status. |
MAC Access | Test results for MAC register test. |
MAC Buffer R/W | Test results for MAC buffer memory test. |
MAC Internal LB | Test results for MAC internal loopback test. |
MAC External LB | Test results for MAC external loopback test. |
LoadGen | Test results for MAC LoadGen test. |
FBIGA Access | Test results for FBIGA register test. |
FBIGA->MAC Buffer R/W | Test results for FBIGA buffer memory test. |
FBIGA->MAC TxDMA | Test results for FBIGA transmit test. |
FBIGA->MAC RxDMA | Test results for FBIGA receive test |
FBIGA->MAC Internal LB | Test results for FBIGA internal loopback test. |
FBIGA->MAC External LB | Test results for FBIGA external loopback test. |
LoadGen | Test results for FBIGA LoadGen test. |
Bus Interface Status | Fields that indicate bus interface status. |
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Mon Oct 4 14:03:03 PDT 1999
Copyright 1989-1999©Cisco Systems Inc.