show counters

Use the show counters command to display hardware counters for a port.

show counters mod/port

Syntax Description

mod/port

Number of the module and the port.

Default

This command has no default setting.

Supported Platforms

Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch

Command Type

Switch command.

Command Mode

Normal.

Usage Guideline

The Catalyst 2948G switch is a fixed configuration switch. All ports are located on module 2; for this reason, if you enter mod_num/port_num 1/N, an error message will be displayed.

Examples

This example shows how to display the counters for port 1 on module 3 (a Token Ring module) on a Catalyst 5000 family or 2926G series switch:


Note The counters displayed may change depending on the module type queried.
64 bit counters
0  ifHCInOctets                 =                    0
1  ifHCInUcastPkts              =                    0
2  ifHCInMulticastPkts          =                    0
3  ifHCInBroadcastPkts          =                    0
4  ifHCOutOctets                =                    0
5  ifHCOutUcastPkts             =                    0
6  ifHCOutMulticastPkts         =                    0
7  ifHCOutBroadcastPkts         =                    0
 
32 bit counters
0  dot5StatsLineErrors                           =           0
1  dot5StatsBurstErrors                          =           0
2  dot5StatsACErrors                             =           0
3  dot5StatsAbortTransErrors                     =           0
4  dot5StatsInternalErrors                       =           0
5  dot5StatsLostFrameErrors                      =           0
6  dot5StatsReceiveCongestions                   =           0
7  dot5StatsFrameCopiedErrors                    =           0
8  dot5StatsTokenErrors                          =           0
9  dot5StatsSoftErrors                           =           0
10 dot5StatsHardErrors                           =           0
11 dot5StatsSignalLoss                           =           0
12 dot5StatsTransmitBeacons                      =           0
13 dot5StatsRecoverys                            =           0
14 dot5StatsLobeWires                            =           0
15 dot5StatsRemoves                              =           0
16 dot5StatsSingles                              =           0
17 dot5StatsFreqErrors                           =           0
18 dot1dSrPortSpecInFrames                       =           0
19 dot1dSrPortSpecOutFrames                      =           0
20 dot1dSrPortApeInFrames                        =           0
21 dot1dSrPortApeOutFrames                       =           0
22 dot1dSrPortSteInFrames                        =           0
23 dot1dSrPortSteOutFrames                       =           0
24 dot1dSrPortSegmentMismatchDiscards            =           0
25 dot1dSrPortDuplicateSegmentDiscards           =           0
26 dot1dSrPortHopCountExceededDiscards           =           0
27 dot1dSrPortDupLanIdOrTreeErrors               =           0
28 dot1dSrPortLanIdMismatches                    =           0
29 tokenRingMLStatsDropEvents                    =           0
30 tokenRingMLStatsMacOctets                     =           0
31 tokenRingMLStatsMacPkts                       =           0
32 tokenRingMLStatsRingPurgeEvents               =           0
33 tokenRingMLStatsRingPurgePkts                 =           0
34 tokenRingMLStatsBeaconEvents                  =           0
35 tokenRingMLStatsBeaconPkts                    =           0
36 tokenRingMLStatsBeaconTime                    =           0
37 tokenRingMLStatsClaimTokenEvents              =           0
38 tokenRingMLStatsClaimTokenPkts                =           0
39 tokenRingMLStatsNAUNChanges                   =           0
40 tokenRingMLStatsLineErrors                    =           0
41 tokenRingMLStatsInternalErrors                =           0
42 tokenRingMLStatsBurstErrors                   =           0
43 tokenRingMLStatsACErrors                      =           0
44 tokenRingMLStatsAbortErrors                   =           0
45 tokenRingMLStatsLostFrameErrors               =           0
46 tokenRingMLStatsCongestionErrors              =           0
47 tokenRingMLStatsFramesCopiedErrors            =           0
48 tokenRingMLStatsFrequencyErrors               =           0
49 tokenRingMLStatsTokenErrors                   =           0
50 tokenRingMLStatsSoftErrorReports              =           0
51 tokenRingMLStatsRingPollEvents                =           0
52 tokenRingMLStatsHistoryActiveStations         =           0
53 tokenRingPStatsDropEvents                     =           0
54 tokenRingPStatsDataOctets                     =           0
55 tokenRingPStatsDataPkts                       =           0
56 tokenRingPStatsDataBroadcastPkts              =           0
57 tokenRingPStatsDataMulticastPkts              =           0
58 tokenRingPStatsDataPkts18to63Octets           =           0
59 tokenRingPStatsDataPkts64to127Octets          =           0
60 tokenRingPStatsDataPkts128to255Octets         =           0
61 tokenRingPStatsDataPkts256to511Octets         =           0
62 tokenRingPStatsDataPkts512to1023Octets        =           0
63 tokenRingPStatsDataPkts1024to2047Octets       =           0
64 tokenRingPStatsDataPkts2048to4095Octets       =           0
65 tokenRingPStatsDataPkts4096to8191Octets       =           0
66 tokenRingPStatsDataPkts8192to18000Octets      =           0
67 tokenRingPStatsDataPktsGreaterThan18000Octets(null) =0
68 dot1dTpPortInFrames                           =           0
69 dot1dTpPortOutFrames                          =           0
70 dot1dTpPortInDiscards                         =           0
Console>
 

Table 2-17 describes the fields in the show counters command output when the command is issued against a Token Ring module port.


Table 2-17: show counters Command Token Ring Output Fields
Field Description
64-Bit Counters

ifHCInOctets

Total number of octets received on the interface, including framing characters. This object is a 64-bit version of ifInOctets.

ifHCInUcastPkts

Number of packets delivered by this sublayer to a higher sublayer not addressed to a multicast or broadcast address. This object is a 64-bit version of ifInUcastPkts.

ifHCInMulticastPkts

Number of packets delivered by this sublayer to a higher sublayer addressed to a multicast address at this sublayer. For a MAC-layer protocol, these addresses include both group and functional addresses. This object is a 64-bit version of ifInMulticastPkts.

ifHCInBroadcastPkts

Number of packets delivered by this sublayer to a higher sublayer addressed to a broadcast address at this sublayer. This object is a 64-bit version of ifInBroadcastPkts.

ifHCOutOctets

Total number of octets transmitted out the interface, including framing characters. This object is a 64-bit version of ifOutOctets.

ifHCOutUcastPkts

Total number of packets that higher-level protocols requested be transmitted and were not addressed to a multicast or broadcast address at this sublayer, including those that were discarded or not sent. This object is a 64-bit version of ifOutUcastPkts.

ifHCOutMulticastPkts

Total number of packets that higher-level protocols requested be transmitted and were addressed to a multicast address at this sublayer, including those that were discarded or not sent. For a MAC-layer protocol, these addresses include both group and functional addresses. This object is a 64-bit version of ifOutMulticastPkts.

ifHCOutBroadcastPkts

Total number of packets that higher-level protocols requested be transmitted and were addressed to a broadcast address at this sublayer, including those that were discarded or not sent. This object is a 64-bit version of ifOutBroadcastPkts.

32-Bit Counters

dot5StatsLineErrors

Number of times a frame or token was copied or repeated by a station.

dot5StatsBurstErrors

Number of times a station detected the absence of transitions for five half-bit timers (burst-five error).

dot5StatsACErrors

Number of times a station received an AMP frame or an SMP frame where the AC bits were both set to 0. This indicates that no station recognized the destination address and copied the frame, and then received another SMP frame where both AC-bits were set to 0 without first receiving an AMP frame. This condition indicates a station that cannot set the A bit and the C bit properly.

dot5StatsAbortTransErrors

Number of times a station transmitted an abort delimiter while transmitting.

dot5StatsInternalErrors

Number of times a station recognized an internal error.

dot5StatsLostFrameErrors

Number of times a station was transmitting and its return-to-repeat timer expired. This condition indicates that a transmitting station in strip mode did not receive the frame trailer before the return-to-repeat timer went off.

32-Bit Counters (continued)

dot5StatsReceiveCongestions

Number of times a station recognized a frame addressed to its specific address but had no available buffer space. This condition indicates a congested station.

dot5StatsFrameCopiedErrors

Number of times a station recognized a frame addressed to its specific address and detected that the frame status field A-bits were set to 1. This condition indicates a possible line hit or duplicate address.

dot5StatsTokenErrors

Number of times a station acting as the active monitor recognized an error condition that required a token to be transmitted.

dot5StatsSoftErrors

Number of soft errors the port detected. Soft errors are recoverable by the MAC-layer protocols. The soft error number directly corresponds to the number of report error MAC frames that this port has transmitted.

dot5StatsHardErrors

Number of times the port detected an immediately recoverable fatal error. This denotes the number of times this port has either transmitted or received a beacon MAC frame.

dot5StatsSignalLoss

Number of times the port detected a loss of signal condition from the ring.

dot5StatsTransmitBeacons

Number of times the port transmitted a beacon frame.

dot5StatsRecoverys

Number of claim token MAC frames received or transmitted after the port received a ring-purge MAC frame. This counter signifies the number of times the ring was purged and had recovered back into a normal operating state.

dot5StatsLobeWires

Number of times the port detected an open or short circuit in the lobe data path. The adapter is closed and the ring state signifies this condition.

dot5StatsRemoves

Number of times the port received a remove ring station MAC frame request. When the port receives this, it enters the closed state.

dot5StatsSingles

Number of times the port sensed that it is the only station on the ring. This occurs if the port is the first one up on a ring or if there is a hardware problem.

dot5StatsFreqErrors

Number of times the port detected that the incoming signal frequency differs from the expected frequency specified by the IEEE 802.5 standard.

dot1dSrPortSpecInFrames

Number of Specifically-Routed frames received.

dot1dSrPortSpecOutFrames

Number of Specifically-Routed frames transmitted.

dot1dSrPortApeInFrames

Number of All-Paths (All-Routes) Explorer frames received.

dot1dSrPortApeOutFrames

Number of All-Paths (All-Routes) Explorer frames transmitted.

dot1dSrPortSteInFrames

Number of Spanning-Tree Explorer frames received.

dot1dSrPortSteOutFrames

Number of Spanning-Tree Explorer frames transmitted.

dot1dSrPortSegmentMismatchDiscards

Number of Explorer frames discarded by this port because the route descriptors field contained an invalid adjacent segment value.

dot1dSrPortDuplicateSegmentDiscards

Number of Explorer frames discarded by this port because the routing descriptor field contained a duplicate segment value.

dot1dSrPortHopCountExceededDiscards

Number of Explorer frames discarded because the number of routing descriptors in the RIF exceeded the specified maximum hop count.

dot1dSrPortDupLanIdOrTreeErrors

Number of duplicate LAN IDs or tree errors. This helps to detect problems in networks containing older IBM source routing bridges.

dot1dSrPortLanIdMismatches

Number of discarded All-Routes Explorer and Spanning-Tree Explorer frames because the last LAN ID in the routing information field did not equal the LAN-in ID. This error can occur in implementations that do only a LAN-in ID and bridge number check instead of a LAN-in ID, bridge number, and LAN-out ID check before forwarding broadcast frames.

32-Bit Counters (continued)

tokenRingMLStatsDropEvents

Number of events when packets were dropped by the probe due to lack of resources. This number is not necessarily the number of packets dropped; it is the number of times this condition was detected. This value is the same as the corresponding tokenRingPStatsDropEvents.

tokenRingMLStatsMacOctets

Number of octets of data in MAC packets (excluding those that were not good frames) received on the network. This excludes framing bits but includes FCS octets.

tokenRingMLStatsMacPkts

Number of MAC packets (excluding packets that were not good frames) received.

tokenRingMLStatsRingPurgeEvents

Number of times that the ring entered the ring-purge state from a normal ring state. The ring-purge state that occurs in response to the claim token or beacon state is not counted.

tokenRingMLStatsRingPurgePkts

Number of ring-purge MAC packets detected by the probe.

tokenRingMLStatsBeaconEvents

Number of times that the ring entered a beaconing state (beaconFrameStreamingState, beaconBitStreamingState, beaconSetRecoveryModeState, or beaconRingSignalLossState) from a non-beaconing state. A change of the source address of the beacon packet does not constitute a new beacon event.

tokenRingMLStatsBeaconPkts

Number of beacon MAC packets detected by the probe.

tokenRingMLStatsBeaconTime

Amount of time that the ring was in the beaconing state.

tokenRingMLStatsClaimTokenEvents

Number of times the ring entered the claim token state from the normal ring state or ring-purge state. The claim token state that comes in response to a beacon state is not counted.

tokenRingMLStatsClaimTokenPkts

Number of claim token MAC packets detected by the probe.

tokenRingMLStatsNAUNChanges

Number of NAUN changes detected by the probe.

tokenRingMLStatsLineErrors

Number of line errors reported in error reporting packets detected by the probe.

tokenRingMLStatsInternalErrors

Number of adapter internal errors reported in error reporting packets detected by the probe.

tokenRingMLStatsBurstErrors

Number of burst errors reported in error reporting packets detected by the probe.

tokenRingMLStatsACErrors

Number of AC (address copied) errors reported in error reporting packets detected by the probe.

tokenRingMLStatsAbortErrors

Number of abort delimiters reported in error reporting packets detected by the probe.

tokenRingMLStatsLostFrameErrors

Number of lost frame errors reported in error reporting packets detected by the probe.

tokenRingMLStatsCongestionErrors

Number of receive congestion errors reported in error reporting packets detected by the probe.

tokenRingMLStatsFramesCopiedErrors

Number of frame-copied errors reported in error reporting packets detected by the probe.

tokenRingMLStatsDropEvents

Number of events where packets were dropped by the probe due to lack of resources. This number is not necessarily the number of packets dropped; it indicates the number of times this condition was detected. This value is the same as the corresponding tokenRingPStatsDropEvents.

tokenRingMLStatsFrequencyErrors

Number of frequency errors reported in error reporting packets detected by the probe.

tokenRingMLStatsTokenErrors

Number of token errors reported in error reporting packets detected by the probe.

tokenRingMLStatsSoftErrorReports

Number of soft error report frames detected by the probe.

tokenRingMLStatsRingPollEvents

Number of ring poll events detected by the probe.

tokenRingMLStatsHistoryActiveStations

Maximum number of active stations on the ring detected by the probe during this sampling interval.

32-Bit Counters (continued)

tokenRingPStatsDropEvents

Number of events where packets were dropped by the probe due to lack of resources. This number is not necessarily the number of packets dropped; it indicates the number of times this condition was detected. This value is the same as the corresponding tokenRingMLStatsDropEvents.

tokenRingPStatsDataOctets

Number of octet data in good frames received on the network (excluding framing bits but including FCS octets) in non-MAC packets.

tokenRingPStatsDataPkts

Number of non-MAC packets in good frames received.

tokenRingPStatsDataBroadcastPkts

Number of good non-MAC frames received that were directed to an LLC broadcast address (0xFFFFFFFFFFFF or 0xC000FFFFFFFF).

tokenRingPStatsDataMulticastPkts

Number of good non-MAC frames received that were directed to a local or global multicast or functional address. This number does not include packets directed to the broadcast address.

tokenRingPStatsDataPkts18to63Octets

Number of good non-MAC frames received between 18 and 63 octets in length inclusive, excluding framing bits, but including FCS octets.

tokenRingPStatsDataPkts64to127Octets

Number of good non-MAC frames received between 64 and 127 octets in length inclusive, excluding framing bits, but including FCS octets.

tokenRingPStatsDataPkts128to255Octets

Number of good non-MAC frames received between 128 and 255 octets in length inclusive, excluding framing bits, but including FCS octets.

tokenRingPStatsDataPkts256to511Octets

Number of good non-MAC frames received between 256 and 511 octets in length inclusive, excluding framing bits, but including FCS octets.

tokenRingPStatsDataPkts512to1023Octets

Number of good non-MAC frames received between 512 and 1023 octets in length inclusive, excluding framing bits, but including FCS octets.

tokenRingPStatsDataPkts1024to2047Octets

Number of good non-MAC frames received between 1024 and 2047 octets in length inclusive, excluding framing bits, but including FCS octets.

tokenRingPStatsDataPkts2048to4095Octets

Number of good non-MAC frames received between 2048 and 4095 octets in length inclusive, excluding framing bits, but including FCS octets.

tokenRingPStatsDataPkts4096to8191Octets

Number of good non-MAC frames received between 4096 and 8191 octets in length inclusive, excluding framing bits, but including FCS octets.

tokenRingPStatsDataPkts8192to18000Octets

Number of good non-MAC frames received between 8192 and 18000 octets in length inclusive, excluding framing bits, but including FCS octets.

tokenRingPStatsDataPktsGreaterThan18000Octets(null)

Number of good non-MAC frames received that were greater than 18000 octets in length, excluding framing bits but including FCS octets.

dot1dTpPortInFrames

Number of frames received by this port from its segment. Frames received on the interface corresponding to this port are counted by this object only if they are for a protocol being processed by the local bridging function, including bridge management frames.

dot1dTpPortOutFrames

Number of frames transmitted by this port to its segment. Frames transmitted on the interface corresponding to this port are counted by this object only if they are for a protocol being processed by the local bridging function, including bridge management frames.

dot1dTpPortInDiscards

Number of valid frames received that were discarded (for example, filtered) by the forwarding process.

When you enter the show counters command against a Catalyst 4000 family or 2948G switch port, the display is similar to that of a Catalyst 5000 family or 2926G series switch.

**GIGABIT PORT
Console> show counters 2/1
0  rxUnicastPacketCount       = 0
1  txUnicastPacketCount       = 0
2  rxMulticastPacketCount     = 0
3  txMulticastPacketCount     = 0
4  rxBroadcastPacketCount     = 0
5  txBroadcastPacketCount     = 0
6  rxByteCount                = 0
7  txByteCount                = 0
8  pkts64                     = 0
9  pkts65to127                = 0
10 pkts128to255               = 0
11 pkts256to511               = 0
12 pkts512to1023              = 0
13 pkts1024to1522             = 0
14 rxNoPacketBufferCount      = 0
15 rxCRCAlignErrorPacketCount = 0
16 rxUndersizedPacketCount    = 0
17 rxOversizedPacketCount     = 0
18 rxFragmentPacketCount      = 0
19 rxJabberPacketCount        = 0
20 pauseControlFramesRx       = 0
21 pauseControlFramesTx       = 0
22 unsupportedOpcodesRx       = 0
23 txQueueNotAvailable        = 0
24 totalCollisionCount        = 0
25 lateCollisionCount         = 0
26 singleCollisionFrames      = 0
27 multipleCollisionFrames    = 0
28 excessiveCollisionFrames   = 0
29 deferredTransmissions      = 0
30 carrierSenseErrors         = 0
31 falseCarrierDuringIdle     = 0
32 symbolErrorDuringCarrier   = 0
33 sequenceErrorDuringCarrier = 0
 
**10/100 PORT
Console> sh counters 3/3
0  rxUnicastPacketCount       = 0
1  txUnicastPacketCount       = 0
2  rxMulticastPacketCount     = 0
3  txMulticastPacketCount     = 0
4  rxBroadcastPacketCount     = 0
5  txBroadcastPacketCount     = 0
6  rxByteCount                = 0
7  txByteCount                = 0
8  pkts64                     = 0
9  pkts65to127                = 0
10 pkts128to255               = 0
11 pkts256to511               = 0
12 pkts512to1023              = 0
13 pkts1024to1522             = 0
14 rxNoPacketBufferCount      = 0
15 rxCRCAlignErrorPacketCount = 0
16 rxUndersizedPacketCount    = 0
17 rxOversizedPacketCount     = 0
18 rxFragmentPacketCount      = 0
19 rxJabberPacketCount        = 0
20 pauseControlFramesRx       = 0
21 pauseControlFramesTx       = 0
22 unsupportedOpcodesRx       = 0
23 txQueueNotAvailable        = 0
24 totalCollisionCount        = 0
25 lateCollisionCount         = 0
26 singleCollisionFrames      = 0
27 multipleCollisionFrames    = 0
28 excessiveCollisionFrames   = 0
29 deferredTransmissions      = 0
30 carrierSenseErrors         = 0
31 falseCarrierDuringIdle     = 0
32 symbolErrorDuringCarrier   = 0
33 sequenceErrorDuringCarrier = 0
 

Table 2-18 describes the additional fields which may be displayed.


Table 2-18: show counters Command Output Fields for Catalyst 4000 Family and
2948G Series Switches
Field Description

txUnicastPacketCount (size 64 bits)

Number of transmitted unicast packets (size 64 bits).

rxUnicastPacketCount (size 64 bits)

Received unicast packets (size 64 bits).

txMulticastPacketCount (size 64 bits)

Number of transmitted multicast packets (size 64 bits).

rxMulticastPacketCount (size 64 bits)

Number of received multicast packets (size 64 bits).

txBroadcastPacketCount (size 64 bits)

Number of transmitted broadcast packets (size 64 bits).

rxBroadcastPacketCount (size 64 bits)

Number of received broadcast packets (size 64 bits).

rxNoPacketBufferCount

Number of received no packet buffer packets.

rxCRCAlignErrorPacketCount

Number of received CRC align error packets.

rxFragmentPacketCount

Number of received fragment packets (size 64 bits).

rxJabberPacketCount

Number of received Jabber packets (size 64 bits).

unsupportedOpcodesRx

Number of unsupported Opcodes received errors.

txQueueNotAvailable

Number of transmit queue not available errors.

totalCollisionCount

Total collision count (Fast Ethernet)

falseCarrierDuringIdle

Number of false carrier duringidle (Fast Ethernet) errors.

symbolErrorDuringCarrier

Number of symbol error during carrier (Fast Ethernet) errors.

SequenceErrorDuringCarrier

Number of sequence error during carrier (Gigabit Ethernet) errors.

Related Command

clear counters

show drip statistics

Use the show drip statistics command to display DRiP statistics.

show drip statistics

Syntax Description

This command has no arguments or keywords.

Default

This command has no default setting.

Supported Platforms

Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch

Command Type

Switch command.

Command Mode

Privileged.

Example

This example shows how to display the DRiP settings:

Console> (enable) show drip statistics
DRiP statistics:
DRiP is Disabled
ARE reduction is Enabled
CRF distribution is Disabled
Input queue drops = 0. Output drops = 0
Console> (enable) 
Related Command

clear drip statistics

show dvlan statistics

Use the show dvlan statistics command to display DVLAN statistics.

show dvlan statistics

Syntax Description

This command has no arguments or keywords.

Default

This command has no default setting.

Supported Platforms

Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch

Command Type

Switch command.

Command Mode

Normal.

Example

This example shows how to display the DVLAN statistical information:

Console> show dvlan statistics
VMPS Client Statistics
----------------------
VQP Queries:               0
VQP Responses:             0
Vmps Changes:              0
VQP Shutdowns:             0
VQP Denied:                0
VQP Wrong Domain:          0
VQP Wrong Version:         0
VQP Insufficient Resource: 0
Console>
 

show fddi

Use the show fddi command to display the settings for FDDI and CDDI modules.

show fddi

Syntax Description

This command has no arguments or keywords.

Default

This command has no default setting.

Supported Platforms

Catalyst 5000 family switches

Command Type

Switch command.

Command Mode

Normal.

Usage Guidelines

This command is not supported by the three-port Gigabit Ethernet switching module (WS-X5403).

Example

This example shows how to display the FDDI settings:

Console> show fddi 
Mod  SMT User-Data               T-Notify  TReq
---  --------------------------  --------  -------
2    Engineering                 30        165000
5    Marketing                   20        150000
 
Port   Tlmin     Ler-CutOff  Ler-Alarm
-----  --------  ----------  ---------
2/1    40        7           8
2/2    40        7           8
5/1    40        10          11
5/2    40        9           12
Console>
 
 

Table 2-19 describes the fields in the show fddi command output.


Table 2-19: show fddi Command Output Fields
Field Description

Mod

Module number.

SMT User-Data

Configured user-data string for the module.

T-Notify

TNotify timer value for the FDDI module.

TReq

TRequest value for the FDDI module.

Port

Module and port number.

Tlmin

TL_MIN value for the FDDI port.

Ler-CutOff

LER-cutoff value for the FDDI port.

Ler-Alarm

LER-alarm value for the FDDI port.

Related Commands

set fddi alarm
set fddi cutoff
set fddi tlmin
set fddi tnotify
set fddi treq
set fddi userdata

show fddicam

Use the show fddicam command to display the FDDI CAM table for a FDDI module.

show fddicam mod_num [fddi] [mac_addr]

Syntax Description

mod_num

Number of the module.

fddi

(Optional) Keyword to cause MAC addresses to display in noncanonical format.

mac_addr

(Optional) Specific MAC address that displays FDDI CAM table information.

Default

This command has no default setting.

Supported Platforms

Catalyst 5000 family switches

Command Type

Switch command.

Command Mode

Normal.

Usage Guidelines

This command is not supported by the three-port Gigabit Ethernet switching module (WS-X5403).

Example

This example shows how to display the FDDI CAM table for module 4:

Console> show fddicam 4
MAC Address        VLAN   Protocol Type
-----------------  ----   -------------
00-40-0b-d0-00-2b     1   FDDI
Total FDDI CAM entries = 1
Console> 
 

Table 2-20 describes the fields in the show fddicam command output.


Table 2-20: show fddicam Command Output Fields
Field Description

MAC Address

MAC address of the FDDI module.

VLAN

VLAN that the MAC address was learned on.

Protocol Type

Protocol type learned for the MAC address.

Total FDDI CAM entries

Total number of FDDI CAM table entries found.

Related Commands

clear cam
set bridge fddicheck
show config

show file

Use the show file command to display the contents of a file.

show file [device:] filename [dump]

Syntax Description

device:

(Optional) Supervisor Engine III only: valid devices are bootflash, slot0, and slot1; Catalyst 4000 family and 2948G supervisor engine module: valid value is bootflash.

filename

Name of the file.

dump

Keyword to show the hex dump of the file.

Default

This command has no default setting.

Supported Platforms

Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch

Command Type

Switch command.

Command Mode

Privileged.

Usage Guideline

A colon (:) is required after the specified device.

Examples

This example shows how to use the show file command on Supervisor Engines III, III F, and
Catalyst 4000 family, 2926G series, and 2948G switch:

Console> (enable) show file slot0:cfgfile
 
begin
#version 5.3(0.11)BOU-Eng
!
set password $1$FMFQ$HfZR5DUszVHIRhrz4h6V70
set enablepass $1$FMFQ$HfZR5DUszVHIRhrz4h6V70
set prompt Console>
set length 24 default
...
Console> (enable)
 

This example shows how to view the hex dump of a file:

Console> (enable) show file slot0:cfgfile dump
8099d140  0A626567 696E0A21 0A237665 7273696F   .begin.!.#versio
8099d150  6E20352E 3328302E 31312942 4F552D45   n 5.3(0.11)BOU-E
8099d160  6E670A21 0A736574 20706173 73776F72   ng.!.set passwor
8099d170  64202431 24464D46 51244866 5A523544   d $1$FMFQ$HfZR5D
8099d180  55737A56 48495268 727A3468 36563730   UszVHIRhrz4h6V70
8099d190  0A736574 20656E61 626C6570 61737320   .set enablepass 
8099d1a0  24312446 4D465124 48665A52 35445573   $1$FMFQ$HfZR5DUs
8099d1b0  7A564849 5268727A 34683656 37300A73   zVHIRhrz4h6V70.s
8099d1c0  65742070 726F6D70 7420436F 6E736F6C   et prompt Consol
8099d1d0  653E0A73 6574206C 656E6774 68203234   e>.set length 24
...
Console> (enable)
 

This example shows how to use the show file command on Supervisor Engines II G and III G:

Console> (enable) show file cfg2
 
begin
!
# ***** NON-DEFAULT CONFIGURATION *****
!
!
# Wed Apr 21 1999, 22:55:10 
!
#version 5.3(0.53-Eng)ASP
!
set prompt test>
!
#frame distribution method
set port channel all distribution mac both
!
#ip
set interface sc0 1 172.20.25.145/255.255.0.0 172.20.255.255
 
set ip route 0.0.0.0/0.0.0.0         172.20.25.201  
!
#set boot command
set boot auto-config non-recurring
!       
#qos
set qos map 1q4t 0 0 cos 0
set qos map 1q4t 0 0 cos 1
set qos map 1q4t 0 0 cos 2
set qos map 1q4t 0 0 cos 3
set qos map 1q4t 0 0 cos 4
set qos map 1q4t 0 0 cos 5
set qos map 1q4t 0 0 cos 6
set qos map 1q4t 0 0 cos 7
set qos wred-threshold 1q4t tx queue 1 0 0 0 0 
!
#module 1 : 4-port 10/100BaseTX Supervisor
!
#module 2 : 24-port 10BaseF Ethernet
!
#module 3 : 12-port 10/100BaseTX Ethernet
!
#module 4 empty
!
#module 5 empty
end
Console> (enable)

show flash

Use the show flash command to list Flash information, including file code names, version numbers, and sizes.

show flash [[m/]device:] [all | chips | filesys]

Syntax Description

m/

(Optional) Supervisor Engine III and Catalyst 4000 family and 2948G switch supervisor engine modules only; module number of the supervisor engine containing the Flash device.

device:

(Optional) Supervisor Engine III only: valid devices are bootflash, slot0, and slot1; Catalyst 4000 family and 2948G switch supervisor engine module: valid value is bootflash.

all

(Optional) Supervisor Engine III and Catalyst 4000 family and 2948G switch supervisor engine module only: keyword used to list deleted files, undeleted files, and files with errors on a Flash memory device.

chips

(Optional) Supervisor Engine III and Catalyst 4000 family and 2948G switch supervisor engine modules only: keyword used to show information about the Flash chip.

filesys

(Optional) Supervisor Engine III and Catalyst 4000 family and 2948G switch supervisor engine modules only: keyword used to show the Device Info Block, the Status Info, and the Usage Info.

Default

This command has no default setting.

Supported Platforms

Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch

Command Type

Switch command.

Command Mode

Normal.

Usage Guideline

A colon (:) is required after the specified device.

Examples

This example shows how to list the Flash information for Supervisor Engines I or II:

Console> show flash
FileVersionSectorSizeBuilt
--------------  ------------  ------------  ------- -----------------
c5000 nmp3.1(213-Eng)02-11160670906/16/98 00:16:21
epld3.13072920 06/14/98 20:33:06
lcp atm3.112-1523747 06/14/98 12:16:37
lcp tr3.112-1528737 06/14/98 12:22:52
lcp c5ip3.112-1523723 06/14/98 12:27:36
lcp 64k3.112-1557100 06/14/98 12:24:57
atm/fddi3.112-1524502 06/14/98 11:57:58
lcp 3603.1(212)12-15120648 06/14/98 12:32:50
mcp3.112-1526278 06/14/98 11:50:41
cfg17124 04/23/99 09:20:50
cfg2849 04/20/99 13:45:01
Console> 
 

The following examples show how to list Flash information for Supervisor Engine III (the output is similar to that displayed for Catalyst4000 family and 2948G switch supervisor engine modules):

Console> show flash
-#- ED --type-- --crc--- -seek-- nlen -length- -----date/time------ name
1.D 22D6B310A100fc0151052123Aug26 1998 15:43:50 cat5k_r47_1.cbi
2.. 243B312DF201ed8151052608Aug27 1998 10:23:30 cat5k_r47_1.cbi
 
6283877 bytes available (2104731 bytes used)
 
Console> show flash chips
******** Intel Series 2+ Status/Register Dump ********
 
ATTRIBUTE MEMORY REGISTERS:
Config Option Reg (4000): 2
Config Status Reg (4002): 0
Card Status   Reg (4100): 1
Write Protect Reg (4104): 4
Voltage Cntrl Reg (410C): 0
Rdy/Busy Mode Reg (4140): 2
 
COMMON MEMORY REGISTERS: Bank 0
Intelligent ID Code  : 8989A0A0
Compatible Status Reg: 8080
Global     Status Reg: B0B0
Block Status Regs:
0 :B0B0B0B0B0B0B0B0B0B0B0B0B0B0B0B0
8:B0B0B0B0B0B0B0B0B0B0B0B0B0B0B0B0
16 :B0B0B0B0B0B0B0B0B0B0B0B0B0B0B0B0
24 :B0B0B0B0B0B0B0B0B0B0B0B0B0B0B0B0
 
COMMON MEMORY REGISTERS: Bank 1
Intelligent ID Code  : 8989A0A0
Compatible Status Reg: 8080
Global     Status Reg: B0B0
Block Status Regs:
0 :B0B0B0B0B0B0B0B0B0B0B0B0B0B0B0B0
8:B0B0B0B0B0B0B0B0B0B0B0B0B0B0B0B0
16 :B0B0B0B0B0B0B0B0B0B0B0B0B0B0B0B0
24 :B0B0B0B0B0B0B0B0B0B0B0B0B0B0B0B0
 
COMMON MEMORY REGISTERS: Bank 2
Intelligent ID Code  : FF00FF
IID Not Intel -- assuming bank not populated
COMMON MEMORY REGISTERS: Bank 3
Intelligent ID Code  : FF00FF
IID Not Intel -- assuming bank not populated
 
COMMON MEMORY REGISTERS: Bank 4
Intelligent ID Code  : FF00FF
IID Not Intel -- assuming bank not populated
 
Console> show flash filesys
 
-------- F I L E   S Y S T E M   S T A T U S --------
Device Number = 0
DEVICE INFO BLOCK:
Magic Number= 6887635File System Vers = 10000(1.0)
Length= 800000Sector Size= 20000
Programming Algorithm= 4Erased State= FFFFFFFF
File System Offset= 20000 Length = 7A0000
MONLIB Offset= 100Length = C730
Bad Sector Map Offset= 1FFF8Length = 8
Squeeze Log Offset= 7C0000Length = 20000
Squeeze Buffer Offset= 7E0000Length = 20000
Num Spare Sectors= 0
Spares:
STATUS INFO:
Writable
NO File Open for Write
Complete Stats
No Unrecovered Errors
USAGE INFO:
Bytes Used= 201D9BBytes Available = 5FE265
Bad Sectors= 0Spared Sectors= 0
OK Files= 1Bytes = 100FC0
Deleted Files= 1Bytes = 100DDB
Files w/Errors= 0Bytes = 0
 
Console> show flash all
-#- ED --type-- --crc--- -seek-- nlen -length- -----date/time------ name
1.D 22D6B310A 100fc0151052123Aug26 1998 15:43:50 cat5k_r47_1.cbi
2.. 243B312DF 201ed8151052608Aug27 1998 10:23:30 cat5k_r47_1.cbi
 
6283877 bytes available (2104731 bytes used)
 
-------- F I L E   S Y S T E M   S T A T U S --------
  Device Number = 0
DEVICE INFO BLOCK:
Magic Number= 6887635File System Vers = 10000    (1.0)
Length= 800000Sector Size      = 20000
Programming Algorithm = 4Erased State     = FFFFFFFF
File System Offset= 20000Length = 7A0000
MONLIB Offset= 100 Length = C730
Bad Sector Map Offset = 1FFF8Length = 8
Squeeze Log Offset= 7C0000Length = 20000
Squeeze Buffer Offset = 7E0000 Length = 20000
Num Spare Sectors= 0
Spares:
STATUS INFO:
Writable
NO File Open for Write
Complete Stats
No Unrecovered Errors
USAGE INFO:
Bytes Used= 201D9BBytes Available = 5FE265
Bad Sectors= 0Spared Sectors= 0
OK Files= 1Bytes = 100FC0
Deleted Files= 1Bytes = 100DDB
Files w/Errors = 0Bytes = 0
 
******** Intel Series 2+ Status/Register Dump ********
 
ATTRIBUTE MEMORY REGISTERS:
Config Option Reg (4000): 2
Config Status Reg (4002): 0
Card Status Reg (4100): 1
Write Protect Reg (4104): 4
Voltage Cntrl Reg (410C): 0
Rdy/Busy Mode Reg (4140): 2
 
COMMON MEMORY REGISTERS: Bank 0
Intelligent ID Code: 8989A0A0
Compatible Status Reg: 8080
Global     Status Reg: B0B0
Block Status Regs:
0 :B0B0B0B0B0B0B0B0B0B0B0B0B0B0B0B0
8:B0B0B0B0B0B0B0B0B0B0B0B0B0B0B0B0
16 :B0B0B0B0B0B0B0B0B0B0B0B0B0B0B0B0
24 :B0B0B0B0B0B0B0B0B0B0B0B0B0B0B0B0
 
COMMON MEMORY REGISTERS: Bank 1
Intelligent ID Code: 8989A0A0
Compatible Status Reg: 8080
Global     Status Reg: B0B0
Block Status Regs:
0 :B0B0B0B0B0B0B0B0B0B0B0B0B0B0B0B0
8:B0B0B0B0B0B0B0B0B0B0B0B0B0B0B0B0
16 :B0B0B0B0B0B0B0B0B0B0B0B0B0B0B0B0
24 :B0B0B0B0B0B0B0B0B0B0B0B0B0B0B0B0
 
COMMON MEMORY REGISTERS: Bank 2
Intelligent ID Code  : FF00FF
IID Not Intel -- assuming bank not populated
 
COMMON MEMORY REGISTERS: Bank 3
Intelligent ID Code  : FF00FF
IID Not Intel -- assuming bank not populated
 
COMMON MEMORY REGISTERS: Bank 4
Intelligent ID Code  : FF00FF
IID Not Intel -- assuming bank not populated
Related Commands

download
resetswitch
show versionswitch
upload

show gmrp configuration

Use the show gmrp configuration command to display complete GMRP-related configuration information.

show gmrp configuration

Syntax Description

This command has no arguments or keywords.

Default

This command has no default setting.

Supported Platforms

Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch

Command Type

Switch command.

Command Mode

Normal.

Usage Guideline

If the port list exceeds the available line spaces, the list wraps to the next line.

Examples

This example shows the display when GMRP is enabled:

Console> (enable) show gmrp configuration
Global GMRP Configuration:
GMRP Feature is currently enabled on this switch.
GMRP Timers (milliseconds):
Join = 200
Leave = 600
LeaveAll = 10000
Port based GMRP Configuration:
GMRP StatusRegistrationForward AllPort
--------------------------------------------------------------------
EnabledFixedDisabled2/1,3/1-2
DisabledNormalDisabled2/5-6
EnabledNormalDisabled1/1-2
Console> (enable) 
Related Command

set gmrp registration

show gmrp statistics

Use the show gmrp statistics command to display all the GMRP-related statistics for a specified VLAN.

show gmrp statistics [vlan]

Syntax Description

vlan

(Optional) VLAN for which to show GMRP statistics.

Default

If no VLAN is specified, the default is that statistics for VLAN 1 are shown.

Supported Platforms

Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch

Command Type

Switch command.

Command Mode

Normal.

Example

This example shows the display for all the GMRP-related statistics for VLAN 23:

Console> show gmrp statistics 23
GMRP Statistics for vlan <23>:
Total valid GMRP Packets Received: 500
Join Emptys:200
Join INs: 250
Leaves:10
Leave Alls:35
Emptys:5
Fwd Alls:0
Fwd Unregistered:0
Total valid GMRP Packets Transmitted: 600
Join Emptys:200
Join INs: 150
Leaves:45
Leave Alls:200
Emptys:5
Fwd Alls:0
Fwd Unregistered:0
Total valid GMRP Packets Received: 0
Total GMRP packets dropped:0
Total GMRP Registrations Failed:0
Console> 
Related Commands

clear gmrp statistics
set gmrp

show gmrp timer

Use the show gmrp timer command to display all the GMRP timers values.

show gmrp timer

Syntax Description

This command has no arguments or keywords.

Default

This command has no default setting.

Supported Platforms

Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch

Command Type

Switch command.

Command Mode

Normal.

Usage Guideline

You can enter the show multicast group command to display GMRP configuration values.

Example

This example shows how to display all the GMRP timer values:

Console> (enable) show gmrp timer
TimerTimer Value(milliseconds)
---------------------------------------------
Join200
Leave600
Leave All10000
Console> (enable)
Related Commands

set gmrp timer
set gvrp timer
set garp timer
show multicast group

show gvrp configuration

Use the show gvrp configuration command to display GVRP configuration information, including timer values, whether GVRP and dynamic VLAN creation is enabled, and which ports are running GVRP.

show gvrp configuration

Syntax Description

This command has no arguments or keywords.

Default

This command has no default setting.

Supported Platforms

Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch

Command Type

Switch command.

Command Mode

Normal.

Usage Guidelines

If the port list exceeds the available line spaces, the list wraps to the next line.

If no ports are GVRP participants, the message output changes from "GVRP Participants running on port_list" to "GVRP Participants running on no ports."

Example

This example shows how to view GVRP configuration information:

Console> show gvrp configuration 
 
Global GVRP Configuration:
GVRP Feature is currently enabled on the switch.
GVRP dynamic VLAN creation is enabled.
GVRP Timers(milliseconds)
Join = 200
Leave = 600
LeaveAll = 10000
 
Port based GVRP Configuration:
GVRP Status Registration Port 
-------------- --------------- -------------------------------------------------------
Enabled     Normal2/1-2,3/1-8,7/1-24,8/1-24 
GVRP Participants running on 3/7-8.
Console>
Related Commands

set gvrp
set gvrp dynamic-vlan-creation
set gvrp registration
set gvrp timer
clear gvrp statistics
show gvrp statistics

show gvrp statistics

Use the show gvrp statistics command to view GVRP statistics for a port.

show gvrp statistics [mod/port]

Syntax Description

mod/port

(Optional) Number of the module and port.

Default

This command has no default setting.

Supported Platforms

Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch

Command Type

Switch command.

Command Mode

Normal.

Example

This example shows how to view GVRP statistics for module 2, port 1:

Console> show gvrp statistics 2/1
GVRP enabled
 
GVRP statistics for port 2/1:
Total valid pkts rcvd:           18951
Total invalid pkts recvd         0
General Queries recvd            377
Group Specific Queries recvd     0
MAC-Based General Queries recvd  0
Leaves recvd                     14
Reports recvd                    16741
Queries  Xmitted                 0
GS Queries Xmitted               16
Reports Xmitted                  0
Leaves Xmitted                   0
Failures to add GDA to EARL      0
Topology Notifications rcvd      10
GVRP packets dropped             0
Console> 
 

Table 2-21 describes the fields in the show gvrp statistics output.


Table 2-21: show gvrp statistics Command Output Fields
Field Description

GVRP Enabled

Status of whether GVRP is enabled or disabled.

Total valid pkts recvd

Total number of valid GVRP packets received.

Total invalid pkts recvd

Total number of invalid GVRP packets received.

General Queries recvd

Total number of GVRP general queries received.

Group Specific Queries recvd

Total number of GVRP group-specific queries received.

MAC-Based General Queries recvd

Total number of MAC-based general queries received.

Leaves recvd

Total number of GVRP leaves received.

Reports recvd

Total number of GVRP reports received.

Queries Xmitted

Total number of GVRP general queries transmitted by the switch.

GS Queries Xmitted

Total number of GVRP group specific-equivalent queries transmitted by the switch.

Reports Xmitted

Total number of GVRP reports transmitted by the switch.

Leaves Xmitted

Total number of GVRP leaves transmitted by the switch.

Failures to add GDA to EARL

Total number of times the switch failed to add a multicast entry (GDA) to the EARL table.

Topology Notifications rcvd

Total number of topology change notifications received by the switch.

GVRP packets dropped

Total number of GVRP packets dropped by the switch.

Related Commands

set gvrp
set gvrp dynamic-vlan-creation
set gvrp registration
set gvrp timer
clear gvrp statistics
show gvrp configuration

show ifindex

Use the show ifindex command to display the information of the specific ifIndex.

show ifindex number

Syntax Description

number

Number of the ifIndex.

Default

This command has no default setting.

Supported Platforms

Catalyst 5000 family switches
Catalyst 4000 family switches
Catalyst 2926G series switches
Catalyst 2948G switch

Command Type

Switch command.

Command Mode

Normal.

Usage Guideline

You can designate multiple ifIndex numbers by separating each number with commas. To specify a range of numbers, use a dash (-) between the low and high numbers.

Example

This example shows how to display ifIndex information:

Console> (enable) show ifindex 1,2,3,4-15
 Ifindex 1 is mapped to interface sc0.
 Ifindex 2 is mapped to interface sl0.
 Ifindex 3 is mapped to port 1/1.
 Ifindex 4 is mapped to port 1/2.
 Ifindex 5 is mapped to port 1/3.
 Ifindex 6 is mapped to port 1/4.
 Ifindex 7 is mapped to vlan 1.
 Ifindex 8 is mapped to vlan 1002.
 Ifindex 9 is mapped to vlan 1004.
 Ifindex 10 is mapped to vlan 1005.
 Ifindex 11 is mapped to vlan 1003.
 Ifindex 12 is mapped to port 9/1.
 Ifindex 13 is mapped to port 9/2.
 Ifindex 14 is mapped to port 9/3.
 Ifindex 15 is mapped to port 9/4.

show igmp statistics

Use the show igmp statistics command to view IGMP statistics for a particular VLAN.

show igmp statistics [vlan_id]

Syntax Description

vlan_id

(Optional) VLAN for which to show IGMP statistics.

Default

If no VLAN is specified, statistics for VLAN 1 are shown.

Supported Platforms

Catalyst 5000 family switches
Catalyst 2926G series switches

Command Type

Switch command.

Command Mode

Normal.

Example

This example shows how to view IGMP statistics for VLAN 1:

Console> show igmp statistics 1
IGMP disabled
IGMP fastleave enabled
 
IGMP statistics for vlan 1:
Total valid pkts rcvd:           18951
Total invalid pkts recvd         0
General Queries recvd            377
Group Specific Queries recvd     0
MAC-Based General Queries recvd  0
Leaves recvd                     14
Reports recvd                    16741
Queries  Xmitted                 0
GS Queries Xmitted               16
Reports Xmitted                  0
Leaves Xmitted                   0
Failures to add GDA to EARL      0
Topology Notifications rcvd      10
IGMP packets dropped             0
Console> 
 

Table 2-22 describes the fields in the show igmp statistics output.


Table 2-22: show igmp statistics Command Output Fields
Field Description

IGMP Enabled

Status of whether IGMP snooping is enabled or disabled.

Total valid pkts rcvd

Total number of valid IGMP packets received.

Total invalid pkts recvd

Total number of invalid IGMP packets received.

General Queries recvd

Total number of IGMP general queries received.

Group Specific Queries recvd

Total number of IGMP group-specific queries received.

MAC-Based General Queries recvd

Total number of MAC-based general queries received.

Leaves recvd

Total number of IGMP leaves received.

Reports recvd

Total number of IGMP reports received.

Queries Xmitted

Total number of IGMP general queries transmitted by the switch.

GS Queries Xmitted

Total number of IGMP group specific-equivalent queries transmitted by the switch.

Reports Xmitted

Total number of IGMP reports transmitted by the switch.

Leaves Xmitted

Total number of IGMP leaves transmitted by the switch.

Failures to add GDA to EARL

Total number of times the switch failed to add a multicast entry (GDA) to the EARL table.

Topology Notifications rcvd

Total number of topology change notifications received by the switch.

IGMP packets dropped

Total number of IGMP packets dropped by the switch.

Related Commands

clear igmp statistics
clear multicast router
set igmp
set igmp fastleave
set multicast router
show multicast router
show multicast group count