This section shows an example network configuration.
Figure 1 shows the example network topology.
The IP addressing and hardware configuration for the network is described in the following tables:

| VLAN | VLAN Name | IP Subnetwork | Hosts | Servers |
|---|---|---|---|---|
1 | default | 10.10.1.0/24 | 0 | 0 |
10 | Corporate | 10.10.10.0/24 | 20 | 2 |
20 | DevEng | 10.10.20.0/24 | 90 | 1 |
30 | Mfg | 10.10.30.0/24 | 30 | 1 |
40 | QA | 10.10.40.0/24 | 45 | 0 |
50 | Finance&Admin | 10.10.50.0/24 | 30 | 0 |
60 | Sales&Mktg | 10.10.60.0/24 | 35 | 0 |
| Slot | Module |
|---|---|
1 | Supervisor Engine III (with 2-port 1000-Mbps Gigabit Ethernet uplinks) |
3 | Route Switch Module (RSM) |
5-6 | 10/100-Mbps Fast Ethernet modules (12-port) |
7-9 | 10-Mbps Ethernet modules (48-port) |
| Slot | Module |
|---|---|
1 | Supervisor engine |
2-3 | 1000-Mbps Gigabit Ethernet modules (6-port) |
| Slot | Module |
|---|---|
1 | Supervisor Engine III (with 4-port 10/100-Mbps Fast Ethernet uplinks) |
2 | 10/100-Mbps Fast Ethernet module (12-port) |
3-5 | 10-Mbps Ethernet modules (48-port) |
| Switch | In-Band (sc0) Interface IP Address |
|---|---|
Catalyst 5509 | 10.10.1.10/24 |
Catalyst 4003 | 10.10.1.20/24 |
Catalyst 5505 | 10.10.1.30/24 |
| Interface | IP Address |
|---|---|
VLAN 1 | 10.10.1.1/24 |
VLAN 10 | 10.10.10.1/24 |
VLAN 20 | 10.10.20.1/24 |
VLAN 30 | 10.10.30.1/24 |
VLAN 40 | 10.10.40.1/24 |
VLAN 50 | 10.10.50.1/24 |
VLAN 60 | 10.10.60.1/24 |
This section shows the configuration for 5509-ER-F1:
Enter password: <Return>
Console> enable
Enter password: <Return>
Console> (enable) set system name 5509-ER-F1
System name set.
5509-ER-F1> (enable) set system location 1st Floor Equipment Room
System location set.
5509-ER-F1> (enable) set system contact sysadmin@bigcorp.com
System contact set.
5509-ER-F1> (enable) set time 04/30/1999 9:30:00
Fri Apr 30 1999, 09:30:00
5509-ER-F1> (enable) set password
Enter old password: <Return>
Enter new password: <new_login_password>
Retype new password: <new_login_password>
Password changed.
5509-ER-F1> (enable) set enablepass
Enter old password: <Return>
Enter new password: <new_enable_password>
Retype new password: <new_enable_password>
Password changed.
5509-ER-F1> (enable) set banner motd %
5509-ER-F1 (Catalyst 5509)
Access Restricted
%
MOTD banner set
5509-ER-F1> (enable) set interface sc0 10.10.1.10 255.255.255.0
Interface sc0 IP address set.
5509-ER-F1> (enable) set ip route default 10.10.1.1
Route added.
5509-ER-F1> (enable) set ip dns server 10.10.10.100
10.10.10.100 added to DNS server table as primary server.
5509-ER-F1> (enable) set ip dns domain bigcorp.com
Default DNS domain name set to bigcorp.com
5509-ER-F1> (enable) set ip dns enable
DNS is enabled
5509-ER-F1> (enable) set vtp domain BigCorp mode server
VTP domain BigCorp modified
5509-ER-F1> (enable) set vlan 10 name Corporate
Vlan 10 configuration successful
5509-ER-F1> (enable) set vlan 20 name DevEng
Vlan 20 configuration successful
5509-ER-F1> (enable) set vlan 30 name Mfg
Vlan 30 configuration successful
5509-ER-F1> (enable) set vlan 40 name QA
Vlan 40 configuration successful
5509-ER-F1> (enable) set vlan 50 name Finance&Admin
Vlan 50 configuration successful
5509-ER-F1> (enable) set vlan 60 name Sales&Mktg
Vlan 60 configuration successful
5509-ER-F1> (enable) set module name 1 Supervisor III
Module name set.
5509-ER-F1> (enable) set port flowcontrol 1/1-2 send off
Ports 1/1-2 flow control send administration status set to off
(ports will not send flowcontrol to far end)
5509-ER-F1> (enable) set port flowcontrol 1/1-2 receive off
Ports 1/1-2 flow control receive administration status set to off
(ports will not allow far end to send flowcontrol)
5509-ER-F1> (enable) set port negotiation 1/1-2 enable
Ports 1/1-2 negotiation enabled
5509-ER-F1> (enable) set port name 1/1-2 GEC 802.1Q Trunk
Ports 1/1-2 name set.
5509-ER-F1> (enable) set port channel 1/1-2 desirable
Port(s) 1/1-2 channel mode set to desirable.
5509-ER-F1> (enable) set trunk 1/1 desirable dot1q
Port(s) 1/1 trunk mode set to desirable.
Port(s) 1/1 trunk type set to dot1q.
5509-ER-F1> (enable) set module name 3 RSM (RSM-ER-F1)
Module name set.
5509-ER-F1> (enable) set module name 5 Fast Ether Uplinks
Module name set.
5509-ER-F1> (enable) set port name 5/1-4 FEC ISL Trunk
Ports 5/1-4 name set.
5509-ER-F1> (enable) set port speed 5/1-4 100
Ports 5/1-4 transmission speed set to 100Mbps.
5509-ER-F1> (enable) set port duplex 5/1-4 full
Ports 5/1-4 set to full-duplex.
5509-ER-F1> (enable) set port flowcontrol 5/1-4 send off
Ports 5/1-4 flow control send administration status set to off
(ports will not send flowcontrol to far end)
5509-ER-F1> (enable) set port flowcontrol 5/1-4 receive off
Ports 5/1-4 flow control receive administration status set to off
(ports will not allow far end to send flowcontrol)
5509-ER-F1> (enable) set port negotiation 5/1-4 enable
Ports 5/1-4 negotiation enabled
5509-ER-F1> (enable) set port channel 5/1-4 desirable
Port(s) 5/1-4 channel mode set to desirable.
5509-ER-F1> (enable) set trunk 5/1 desirable isl
Port(s) 5/1 trunk mode set to desirable.
Port(s) 5/1 trunk type set to isl.
5509-ER-F1> (enable) set module name 6 DevEng 100Mb Hosts
Module name set.
5509-ER-F1> (enable) set port name 6/1 DE Sparc Ultra
Port 6/1 name set.
5509-ER-F1> (enable) set port name 6/2-7 DE Sparc20
Ports 6/2-7 name set.
5509-ER-F1> (enable) set port name 6/8-12 DE NT Workstation
Ports 6/8-12 name set.
5509-ER-F1> (enable) set port speed 6/1-12 100
Ports 6/1-12 transmission speed set to 100Mbps.
5509-ER-F1> (enable) set port duplex 6/1-12 full
Ports 6/1-12 set to full-duplex.
5509-ER-F1> (enable) set port flowcontrol 6/1-12 send desired
Ports 6/1-12 flow control send administration status set to desired
(ports will send flowcontrol to far end if far end supports it)
5509-ER-F1> (enable) set port flowcontrol 6/1-12 receive desired
Ports 6/1-12 flow control receive administration status set to desired
(ports will allow far end to send flowcontrol if far end supports it)
5509-ER-F1> (enable) set port channel 6/1-12 off
Port(s) 6/1-12 channel mode set to off.
5509-ER-F1> (enable) set trunk 6/1-12 off
Port(s) 6/1-12 trunk mode set to off.
5509-ER-F1> (enable) set spantree portfast 6/1-12 enable
Warning: Spantree port fast start should only be enabled on ports connected
to a single host. Connecting hubs, concentrators, switches, bridges, etc. to
a fast start port can cause temporary spanning tree loops. Use with caution.
Spantree ports 6/1-12 fast start enabled.
5509-ER-F1> (enable) set vlan 20 6/1-12
VLAN 20 modified.
VLAN 1 modified.
VLAN Mod/Ports
---- -----------------------
20 1/1-2
5/1-4
6/1-12
5509-ER-F1> (enable) set module name 7 Corp/Mfg 10Mb Hosts
Module name set.
5509-ER-F1> (enable) set port name 7/1-12 Corp Win98 PC
Ports 7/1-12 name set.
5509-ER-F1> (enable) set port name 7/13-48 Mfg Win98 PC
Ports 7/13-48 name set.
5509-ER-F1> (enable) set port duplex 7/1-48 full
Ports 7/1-48 set to full-duplex.
5509-ER-F1> (enable) set spantree portfast 7/1-48 enable
Warning: Spantree port fast start should only be enabled on ports connected
to a single host. Connecting hubs, concentrators, switches, bridges, etc. to
a fast start port can cause temporary spanning tree loops. Use with caution.
Spantree ports 7/1-48 fast start enabled.
5509-ER-F1> (enable) set vlan 10 7/1-12
VLAN 10 modified.
VLAN 1 modified.
VLAN Mod/Ports
---- -----------------------
10 1/1-2
5/1-4
7/1-12
5509-ER-F1> (enable) set vlan 30 7/13-48
VLAN 30 modified.
VLAN 1 modified.
VLAN Mod/Ports
---- -----------------------
30 1/1-2
5/1-4
7/13-48
5509-ER-F1> (enable) set module name 8 DevEng 10Mb Hosts
Module name set.
5509-ER-F1> (enable) set port name 8/1-48 DevEng WinNT PC
Ports 8/1-48 name set.
5509-ER-F1> (enable) set port duplex 8/1-48 full
Ports 8/1-48 set to full-duplex.
5509-ER-F1> (enable) set spantree portfast 8/1-48 enable
Warning: Spantree port fast start should only be enabled on ports connected
to a single host. Connecting hubs, concentrators, switches, bridges, etc. to
a fast start port can cause temporary spanning tree loops. Use with caution.
Spantree ports 8/1-48 fast start enabled.
5509-ER-F1> (enable) set vlan 20 8/1-48
VLAN 20 modified.
VLAN 1 modified.
VLAN Mod/Ports
---- -----------------------
20 1/1-2
5/1-4
6/1-12
8/1-48
5509-ER-F1> (enable) set module name 9 DevEng 10Mb Hosts
Module name set.
5509-ER-F1> (enable) set port name 9/1-48 DevEng WinNT PC
Ports 9/1-48 name set.
5509-ER-F1> (enable) set port duplex 9/1-48 full
Ports 9/1-48 set to full-duplex.
5509-ER-F1> (enable) set spantree portfast 9/1-48 enable
Warning: Spantree port fast start should only be enabled on ports connected
to a single host. Connecting hubs, concentrators, switches, bridges, etc. to
a fast start port can cause temporary spanning tree loops. Use with caution.
Spantree ports 9/1-48 fast start enabled.
5509-ER-F1> (enable) set vlan 20 9/1-48
VLAN 20 modified.
VLAN 1 modified.
VLAN Mod/Ports
---- -----------------------
20 1/1-2
5/1-4
6/1-12
8/1-48
9/1-48
5509-ER-F1> (enable)
This section shows the configuration for 4003-ER-F1:
Enter password: <Return>
Console> enable
Enter password: <Return>
Console> (enable) set system name 4003-ER-F1
System name set.
4003-ER-F1> (enable) set system location 1st Floor Equipment Room
System location set.
4003-ER-F1> (enable) set system contact sysadmin@bigcorp.com
System contact set.
4003-ER-F1> (enable) set time 04/30/1999 9:45:00
Fri Apr 30 1999, 09:45:00
4003-ER-F1> (enable) set password
Enter old password: <Return>
Enter new password: <new_login_password>
Retype new password: <new_login_password>
Password changed.
4003-ER-F1> (enable) set enablepass
Enter old password: <Return>
Enter new password: <new_enable_password>
Retype new password: <new_enable_password>
Password changed.
4003-ER-F1> (enable) set banner motd %
4003-ER-F1 (Catalyst 4003)
Access Restricted
%
MOTD banner set
4003-ER-F1> (enable) set interface sc0 10.10.1.20 255.255.255.0
Interface sc0 IP address set.
4003-ER-F1> (enable) set ip route default 10.10.1.1
Route added.
4003-ER-F1> (enable) set ip dns server 10.10.10.100
10.10.10.100 added to DNS server table as primary server.
4003-ER-F1> (enable) set ip dns domain bigcorp.com
Default DNS domain name set to bigcorp.com
4003-ER-F1> (enable) set ip dns enable
DNS is enabled
4003-ER-F1> (enable) set vtp domain BigCorp mode client
VTP domain BigCorp modified
4003-ER-F1> (enable) set module name 1 Supervisor
Module name set.
4003-ER-F1> (enable) set module name 2 Gig Uplinks
Module name set.
4003-ER-F1> (enable) set port flowcontrol 2/1-2 send off
Ports 2/1-2 flow control send administration status set to off
(ports will not send flowcontrol to far end)
4003-ER-F1> (enable) set port flowcontrol 2/1-2 receive off
Ports 2/1-2 flow control receive administration status set to off
(ports will not allow far end to send flowcontrol)
4003-ER-F1> (enable) set port negotiation 2/1-2 enable
Ports 2/1-2 negotiation enabled
4003-ER-F1> (enable) set port name 2/1-2 GEC 802.1Q Trunk
Ports 2/1-2 name set.
4003-ER-F1> (enable) set port channel 2/1-2 desirable
Port(s) 2/1-2 channel mode set to desirable.
4003-ER-F1> (enable) set trunk 2/1 desirable dot1q
Port(s) 2/1-2 trunk mode set to desirable.
Port(s) 2/1-2 trunk type set to dot1q.
4003-ER-F1> (enable) set module name 3 Gig Server Links
Module name set.
4003-ER-F1> (enable) set port name 3/1-2 Corporate Server
Ports 3/1-2 name set.
4003-ER-F1> (enable) set port name 3/3 DevEng Server
Port 3/3 name set.
4003-ER-F1> (enable) set port name 3/4 QA Server
Port 3/4 name set.
4003-ER-F1> (enable) set port flowcontrol 3/1-4 send desired
Ports 3/1-4 flow control send administration status set to desired
(ports will send flowcontrol to far end if far end supports it)
4003-ER-F1> (enable) set port flowcontrol 3/1-4 receive desired
Ports 3/1-4 flow control receive administration status set to desired
(ports will allow far end to send flowcontrol if far end supports it)
4003-ER-F1> (enable) set port channel 3/1-2 off
Port(s) 3/1-2 channel mode set to off.
4003-ER-F1> (enable) set port channel 3/3-4 off
Port(s) 3/3-4 channel mode set to off.
4003-ER-F1> (enable) set trunk 3/1-4 off
Port(s) 3/1-4 trunk mode set to off.
4003-ER-F1> (enable) set spantree portfast 3/1-4 enable
Warning: Spantree port fast start should only be enabled on ports connected
to a single host. Connecting hubs, concentrators, switches, bridges, etc. to
a fast start port can cause temporary spanning tree loops. Use with caution.
Spantree ports 3/1-4 fast start enabled.
4003-ER-F1> (enable) set vlan 10 3/1-2
VLAN 10 modified.
VLAN 1 modified.
VLAN Mod/Ports
---- -----------------------
10 2/1-2
3/1-2
4003-ER-F1> (enable) set vlan 20 3/3
VLAN 20 modified.
VLAN 1 modified.
VLAN Mod/Ports
---- -----------------------
20 2/1-2
3/3
4003-ER-F1> (enable) set vlan 40 3/4
VLAN 40 modified.
VLAN 1 modified.
VLAN Mod/Ports
---- -----------------------
40 2/1-2
3/4
4003-ER-F1> (enable)
This section shows the configuration for RSM-ER-F1:
5509-ER-F1> (enable) session 3 Trying Router-3... Connected to Router-3. Escape character is '^]'. Router>enable Router#configure terminal Enter configuration commands, one per line. End with CNTL/Z. Router(config)#hostname RSM-ER-F1 RSM-ER-F1(config)#enable password extra_secret_word RSM-ER-F1(config)#line vty 0 6 RSM-ER-F1(config-line)#password secret_word RSM-ER-F1(config-line)#ip domain-name bigcorp.com RSM-ER-F1(config)#ip name-server 10.10.10.100 RSM-ER-F1(config)#ip domain-lookup RSM-ER-F1(config)#interface vlan 1 RSM-ER-F1(config-if)#description default (vlan1) VLAN interface RSM-ER-F1(config-if)#ip address 10.10.1.1 255.255.255.0 RSM-ER-F1(config-if)#no shutdown RSM-ER-F1(config-if)#interface vlan 10 RSM-ER-F1(config-if)#description Corporate (vlan10) VLAN interface RSM-ER-F1(config-if)#ip address 10.10.10.1 255.255.255.0 RSM-ER-F1(config-if)#no shutdown RSM-ER-F1(config-if)#interface vlan 20 RSM-ER-F1(config-if)#description DevEng (vlan20) VLAN interface RSM-ER-F1(config-if)#ip address 10.10.20.1 255.255.255.0 RSM-ER-F1(config-if)#no shutdown RSM-ER-F1(config-if)#interface vlan 30 RSM-ER-F1(config-if)#description Mfg (vlan30) VLAN interface RSM-ER-F1(config-if)#ip address 10.10.30.1 255.255.255.0 RSM-ER-F1(config-if)#no shutdown RSM-ER-F1(config-if)#interface vlan 40 RSM-ER-F1(config-if)#description QA (vlan40) VLAN interface RSM-ER-F1(config-if)#ip address 10.10.40.1 255.255.255.0 RSM-ER-F1(config-if)#no shutdown RSM-ER-F1(config-if)#interface vlan 50 RSM-ER-F1(config-if)#description Finance&Admin (vlan50) VLAN interface RSM-ER-F1(config-if)#ip address 10.10.50.1 255.255.255.0 RSM-ER-F1(config-if)#no shutdown RSM-ER-F1(config-if)#interface vlan 60 RSM-ER-F1(config-if)#description Sales&Mktg (vlan60) VLAN interface RSM-ER-F1(config-if)#ip address 10.10.60.1 255.255.255.0 RSM-ER-F1(config-if)#no shutdown RSM-ER-F1(config-if)#^Z RSM-ER-F1#copy running-config startup-config Building configuration... [OK] RSM-ER-F1#
This section shows the configuration for 5505-WC-F2:
Enter password: <Return>
Console> enable
Enter password: <Return>
Console> (enable) set system name 5505-WC-F2
System name set.
5505-WC-F2> (enable) set system location 2nd Floor Wiring Closet
System location set.
5505-WC-F2> (enable) set system contact sysadmin@bigcorp.com
System contact set.
5505-WC-F2> (enable) set time 04/30/1999 10:00:00
Fri Apr 30 1999, 10:00:00
5505-WC-F2> (enable) set password
Enter old password: <Return>
Enter new password: <new_login_password>
Retype new password: <new_login_password>
Password changed.
5505-WC-F2> (enable) set enablepass
Enter old password: <Return>
Enter new password: <new_enable_password>
Retype new password: <new_enable_password>
Password changed.
5505-WC-F2> (enable) set banner motd %
5505-WC-F2 (Catalyst 5505)
Access Restricted
%
MOTD banner set
5505-WC-F2> (enable) set interface sc0 10.10.1.30 255.255.255.0
Interface sc0 IP address set.
5505-WC-F2> (enable) set ip route default 10.10.1.1
Route added.
5505-WC-F2> (enable) set ip dns server 10.10.10.100
10.10.10.100 added to DNS server table as primary server.
5505-WC-F2> (enable) set ip dns domain bigcorp.com
Default DNS domain name set to bigcorp.com
5505-WC-F2> (enable) set ip dns enable
DNS is enabled
5505-WC-F2> (enable) set vtp domain BigCorp mode client
VTP domain BigCorp modified
5505-WC-F2> (enable) set module name 1 Supervisor III
Module name set.
5505-WC-F2> (enable) set port name 1/1-4 FEC ISL Trunk
Ports 1/1-4 name set.
5505-WC-F2> (enable) set port speed 1/1-4 100
Ports 1/1-4 transmission speed set to 100Mbps.
5505-WC-F2> (enable) set port duplex 1/1-4 full
Ports 1/1-4 set to full-duplex.
5505-WC-F2> (enable) set port flowcontrol 1/1-4 send off
Ports 1/1-4 flow control send administration status set to off
(ports will not send flowcontrol to far end)
5505-WC-F2> (enable) set port flowcontrol 1/1-4 receive off
Ports 1/1-4 flow control receive administration status set to off
(ports will not allow far end to send flowcontrol)
5505-WC-F2> (enable) set port negotiation 1/1-4 enable
Ports 1/1-4 negotiation enabled
5505-WC-F2> (enable) set port channel 1/1-4 desirable
Port(s) 1/1-4 channel mode set to desirable.
5505-WC-F2> (enable) set trunk 1/1 desirable isl
Port(s) 1/1 trunk mode set to desirable.
Port(s) 1/1 trunk type set to isl.
5505-WC-F2> (enable) set module name 2 QA 100Mb Hosts
Module name set.
5505-WC-F2> (enable) set port name 2/1-4 QA Sparc20
Port 2/1-4 name set.
5505-WC-F2> (enable) set port name 2/5-12 QA NT Workstation
Ports 2/5-12 name set.
5505-WC-F2> (enable) set port speed 2/1-12 100
Ports 2/1-12 transmission speed set to 100Mbps.
5505-WC-F2> (enable) set port duplex 2/1-12 full
Ports 2/1-12 set to full-duplex.
5505-WC-F2> (enable) set port flowcontrol 2/1-12 send desired
Ports 2/1-12 flow control send administration status set to desired
(ports will send flowcontrol to far end if far end supports it)
5505-WC-F2> (enable) set port flowcontrol 2/1-12 receive desired
Ports 2/1-12 flow control receive administration status set to desired
(ports will allow far end to send flowcontrol if far end supports it)
5505-WC-F2> (enable) set port channel 2/1-12 off
Port(s) 2/1-12 channel mode set to off.
5505-WC-F2> (enable) set trunk 2/1-12 off
Port(s) 2/1-12 trunk mode set to off.
5505-WC-F2> (enable) set spantree portfast 2/1-12 enable
Warning: Spantree port fast start should only be enabled on ports connected
to a single host. Connecting hubs, concentrators, switches, bridges, etc. to
a fast start port can cause temporary spanning tree loops. Use with caution.
Spantree ports 2/1-12 fast start enabled.
5505-WC-F2> (enable) set vlan 40 2/1-12
VLAN 40 modified.
VLAN 1 modified.
VLAN Mod/Ports
---- -----------------------
40 1/1-4
2/1-12
5505-WC-F2> (enable) set module name 3 QA 10Mb Hosts
Module name set.
5505-WC-F2> (enable) set port name 3/1-48 QA WinNT PC
Ports 3/1-48 name set.
5505-WC-F2> (enable) set port duplex 3/1-48 full
Ports 3/1-48 set to full-duplex.
5505-WC-F2> (enable) set spantree portfast 3/1-48 enable
Warning: Spantree port fast start should only be enabled on ports connected
to a single host. Connecting hubs, concentrators, switches, bridges, etc. to
a fast start port can cause temporary spanning tree loops. Use with caution.
Spantree ports 3/1-48 fast start enabled.
5505-WC-F2> (enable) set vlan 40 3/1-48
VLAN 40 modified.
VLAN 1 modified.
VLAN Mod/Ports
---- -----------------------
40 1/1-4
2/1-12
3/1-48
5505-WC-F2> (enable) set module name 4 Corp/F&A 10Mb Hosts
Module name set.
5505-WC-F2> (enable) set port name 4/1-12 Corp Win98 PC
Ports 4/1-12 name set.
5505-WC-F2> (enable) set port name 4/13-48 F&A Win98 PC
Ports 4/13-48 name set.
5505-WC-F2> (enable) set port duplex 4/1-48 full
Ports 4/1-48 set to full-duplex.
5505-WC-F2> (enable) set spantree portfast 4/1-48 enable
Warning: Spantree port fast start should only be enabled on ports connected
to a single host. Connecting hubs, concentrators, switches, bridges, etc. to
a fast start port can cause temporary spanning tree loops. Use with caution.
Spantree ports 4/1-48 fast start enabled.
5505-WC-F2> (enable) set vlan 10 4/1-12
VLAN 10 modified.
VLAN 1 modified.
VLAN Mod/Ports
---- -----------------------
10 1/1-4
4/1-12
5505-WC-F2> (enable) set vlan 50 4/13-48
VLAN 50 modified.
VLAN 1 modified.
VLAN Mod/Ports
---- -----------------------
50 1/1-4
4/13-48
5505-WC-F2> (enable) set module name 5 S&M 10Mb Hosts
Module name set.
5505-WC-F2> (enable) set port name 5/1-48 S&M Win98 PC
Ports 5/1-48 name set.
5505-WC-F2> (enable) set port duplex 5/1-48 full
Ports 5/1-48 set to full-duplex.
5505-WC-F2> (enable) set spantree portfast 5/1-48 enable
Warning: Spantree port fast start should only be enabled on ports connected
to a single host. Connecting hubs, concentrators, switches, bridges, etc. to
a fast start port can cause temporary spanning tree loops. Use with caution.
Spantree ports 5/1-48 fast start enabled.
5505-WC-F2> (enable) set vlan 60 5/1-48
VLAN 60 modified.
VLAN 1 modified.
VLAN Mod/Ports
---- -----------------------
60 1/1-4
5/1-48
5505-WC-F2> (enable)
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Wed Jun 2 11:49:51 PDT 1999
Copyright 1989-1999©Cisco Systems Inc.