This chapter describes how to configure permanent virtual connection (PVC)-supported virtual LANs (VLANs) and PVC-supported VLANs with traffic shaping for the Catalyst 5000 series ATM modules.
This chapter consists of these sections:
PVC-based ATM links allow Catalyst 5000 series switches to connect to each other through ATM interfaces over PVCs. You can configure one or more PVCs for each VLAN on every Catalyst 5000 series ATM module. Connectivity can be back-to-back or through an ATM switch cloud, using RFC 1483-compliant, bridged Logical Link Control/Subnetwork Access Protocol (LLC/SNAP) packet encapsulation.
When you create a PVC, you create a virtual channel descriptor (VCD) and attach it to the virtual path identifier (VPI) and virtual channel identifier (VCI). A VCD identifies the VPI-VCI pair for a particular packet. The ATM module requires this feature to manage packet transmission. The number chosen for the VCD is independent of the VPI-VCI pair used.
To use PVCs, you must configure PVCs in both the Catalyst 5000 series ATM module and the ATM switch cloud. PVCs remain active until the circuit is removed from either configuration.
PVCs are compatible with switched virtual connection (SVC)-based LAN Emulation (LANE), with the following restrictions:
You can configure PVCs with Catalyst 5000 series ATM software release 3.2 or with ATM PVC traffic-shaping software release 50.1 or 51.1. Software releases 50.1 and 51.1 allow you to configure a VLAN to run over PVCs so that you can specify a cell rate for traffic flow.
| Caution The ATM single PHY OC-3, dual PHY OC-3, and dual PHY DS3 modules require compatible releases of the Catalyst 5000 series supervisor engine and ATM PVC traffic-shaping software. See Table 36-1 for a list of ATM modules and compatible software releases. |
| Module | Product Number | Supervisor Engine Software Release | ATM PVC Software Release |
|---|---|---|---|
ATM Single PHY OC-3 | WS-X5153 WS-X5154 WS-X5155 | 1.6 or above | 50.1(1) or above |
ATM Dual PHY OC-3 | WS-X5156 WS-X5157 WS-X5158 | 2.1(5) or above | 50.1(1) or above |
ATM Dual PHY DS3 | WS-X5166 | 3.1 or above | 51.1(2) or above |
Figure 36-1 shows two Catalyst 5000 series switches with ATM dual PHY DS3 modules in a redundant configuration running ATM PVC traffic-shaping software. The ATM dual PHY DS3 modules contain ten rate queues. Twenty-four PVCs are divided among the ten rate queues; each specifies a particular cell rate for the PVC set attached to it. In this example, PVC 1 through PVC 7 are in VLAN 1, PVC 8 through PVC 20 are in VLAN 2, and PVC 21 through PVC 24 are in VLAN 3.
To configure ATM PVC traffic shaping, you must assign a specified cell rate to a PVC. The software places the PVC to which the cell rate has been assigned in a dynamically created rate queue. The software creates rate queues, and you can assign each queue a unique cell-rate value.
Ten rate queues are available on any ATM module. However, the allowable peak cell rate (PCR) range varies depending on the software release and ATM module you are using, as follows:
You can configure up to 4096 PVCs on the ATM module. In addition, you can divide the PVCs attached to the rate queues among different VLANs. Traffic shaping supports only PCR.
If you enable VLAN Trunk Protocol (VTP) in the ATM module, the ATM module creates LAN Emulation Clients (LECs) for each VLAN configured on the supervisor engine module. The ATM module software also deletes a previously existing LEC for a particular VLAN when that LEC is configured to run over a PVC.

Table 36-2 shows the default ATM PVC traffic-shaping configuration.
| Feature | Default Configuration |
|---|---|
Clock internal | Transmit clock is generated internally |
ATM framing | C-Bit with ADM |
Line buildout | Short |
DS3-scramble | Disabled |
These sections describe how to configure PVC-supported VLANs on the Catalyst 5000 series ATM modules:
To configure a PVC within the ATM cloud, refer to the documentation from your ATM switch vendor.
To set up a PVC-supported VLAN on the ATM module, perform this task in privileged mode:
| Task | Command |
|---|---|
Step 1 On the Catalyst 5000 series switch, assign an Ethernet port to the desired VLAN. | set vlan vlan_num mod_num/port_num |
Step 2 Establish a connection to the ATM module. | session mod_num |
Step 3 Activate privileged mode on the ATM module. | enable |
Step 4 Enter configuration mode. | configure terminal |
Step 5 Select the ATM interface. | interface atm0 |
Step 6 Set up the PVCs. | atm pvc vcd vpi vci aal5snap |
Step 7 Bind the PVCs to the VLAN. | atm bind pvc vlan vcd vlan_num |
Step 8 (Optional) Set up other PVCs for the same VLAN if needed by repeating Steps 6 and 7. |
|
Step 9 Exit configuration mode. | Ctrl-Z |
Step 10 Verify the PVC configuration. | show atm vlan |
Step 11 Save the configuration. | write memory |
To configure a PVC-supported VLAN with ATM PVC traffic-shaping, perform this task in privileged mode:
| Task | Command |
|---|---|
Step 1 Assign an Ethernet port to the desired VLAN. | set vlan vlan_num mod_num/port_num |
Step 2 Establish a connection to the ATM module. | session mod_num |
Step 3 Activate privileged mode on the ATM module. | enable |
Step 4 Enter configuration mode. | configure terminal |
Step 5 Select the ATM interface. | interface atm0 |
Step 6 (Optional) Customize the interface configuration if needed. | atm clock internal |
Step 7 Set up the PVCs, indicating the desired peak cell rate. | atm pvc vcd vpi vci [aal-encap] aal5snap1 peak2 [oam seconds] |
Step 8 Bind the PVCs to the VLAN. | atm bind pvc vlan vcd vlan_num3 |
Step 9 Set up other PVCs for the same VLAN if needed by repeating Steps 6 through 8. |
|
Step 10 Exit configuration mode. | Ctrl-Z |
Step 11 Verify the setup. | show atm vlan |
Step 12 Write the configuration to NVRAM. | write memory |
You can unbind and remove a previously assigned PVC from a VLAN. You can also unbind a previously assigned PVC from a VLAN without removing the PVC itself. If you do not remove the PVC itself, you can bind the PVC to a different VLAN.
To remove a previously assigned PVC from a VLAN, perform this task in privileged mode:
| Task | Command |
|---|---|
Step 1 Enter privileged mode on the ATM module. | enable |
Step 2 Enter configuration mode. | configure terminal |
Step 3 Select the ATM interface. | interface atm0 |
Step 4 Remove the PVC from the VLAN. | no atm pvc vcd |
Step 5 End the session. | Ctrl-Z |
To unbind a previously assigned PVC from a VLAN without removing the PVC itself, perform this task in privileged mode:
| Task | Command |
|---|---|
Step 1 Activate privileged mode on the ATM module. | enable |
Step 2 Enter configuration mode. | configure terminal |
Step 3 Select the ATM interface. | interface atm0 |
Step 4 Unbind the PVC from the VLAN. | no atm bind pvc vlan vcd vlan_num |
Step 5 End the session. | Ctrl-Z |
These sections show ATM PVC traffic-shaping configuration examples:
This example configuration describes how to configure a nonredundant PVC-supported VLAN configuration with traffic-shaping. Figure 36-2 shows the network used in this example. Assume that the ATM module in each Catalyst 5000 series switch is in slot 2. This example applies to both the single and dual PHY OC-3 ATM modules and the dual PHY DS3 ATM module.

Table 36-3 shows the VLAN and switch connections, VPIs, VCIs, and traffic rates for the network shown in Figure 36-3.
| PVC | VLAN/Switch Connections | VPI | VCI | Rate in kbps |
|---|---|---|---|---|
1 | Connects Switch 1 to Switch 2 on VLAN 5 | 0 | 32 | 45000 |
2 | Connects Switch 2 to Switch 3 on VLAN 5 | 0 | 33 | 2080 |
3 | Connects Switch 1 to Switch 3 on VLAN 5 | 0 | 34 | 45000 |
These assumptions apply for this example:
Before configuring the VLAN over PVCs, you must perform these tasks:
Step 1 Create PVC 1 within the ATM cloud. Enter these commands on the LightStream 1010 ATM switch:
Switch> enable Switch# Switch# configure terminal Enter configuration commands, one per line. End with CNTL/Z. Switch(config)# interface atm0/0/0 Switch(config-if)# atm pvc 0 32 interface atm0/0/1 0 32 Switch(config-if)# end Switch#
Step 2 Verify the setup of PVC 1. Enter this command on the LightStream 1010 ATM switch:
Switch# show atm vc interface atm0/0/0 Interface VPI VCI Type X-Interface X-VPI X-VCI Status ATM0/0/0 0 5 PVC ATM2/0/0 0 32 UP ATM0/0/0 0 16 PVC ATM2/0/0 0 33 UP ATM0/0/0 0 18 PVC ATM2/0/0 0 34 UP ATM0/0/0 0 32 PVC ATM0/0/1 0 32 UP Switch#
Step 3 Create PVC 2 within the ATM cloud. Enter these commands on the LightStream 1010 ATM switch:
Switch# configure terminal Enter configuration commands, one per line. End with CNTL/Z. Switch(config)# Switch(config)# interface atm0/0/1 Switch(config-if)# atm pvc 0 33 interface atm0/0/2 0 33 Switch(config-if)# end Switch#
Step 4 Verify the setup of PVC 2. Enter this command on the LightStream 1010 ATM switch:
Switch# show atm vc interface atm0/0/1 Interface VPI VCI Type X-Interface X-VPI X-VCI Status ATM0/0/1 0 5 PVC ATM2/0/0 0 35 UP ATM0/0/1 0 16 PVC ATM2/0/0 0 36 UP ATM0/0/1 0 18 PVC ATM2/0/0 0 37 UP ATM0/0/1 0 32 PVC ATM0/0/0 0 32 UP ATM0/0/1 0 33 PVC ATM0/0/2 0 33 UP Switch#
Step 5 Create PVC 3 within the ATM cloud. Enter these commands on the LightStream 1010 ATM switch:
Switch# configure terminal Enter configuration commands, one per line. End with CNTL/Z. Switch(config-if)# interface atm0/0/2 Switch(config-if)# atm pvc 0 34 interface atm0/0/0 0 34 Switch(config-if)# end Switch#
Step 6 Verify the setup of PVC 3. Enter this command on the LightStream 1010 ATM switch:
Switch# show atm vc interface atm0/0/2 Interface VPI VCI Type X-Interface X-VPI X-VCI Status ATM0/0/2 0 5 PVC ATM2/0/0 0 38 UP ATM0/0/2 0 16 PVC ATM2/0/0 0 39 UP ATM0/0/2 0 18 PVC ATM2/0/0 0 40 UP ATM0/0/2 0 33 PVC ATM0/0/1 0 33 UP ATM0/0/2 0 34 PVC ATM0/0/0 0 34 UP Switch#
Step 7 At the console of the Catalyst 5000 series Switch 1, establish a connection to the ATM module in slot 2 by entering these commands:
Console> enable Enter password: Console> (enable) set vlan 5 Console> (enable) session 2 Trying ATM-2... Connected to ATM-2. Escape character is '^]'. ATM>
Step 8 Configure PVC 1 and PVC 3 on Switch 1 by entering these commands:
ATM> enable ATM# configure terminal Enter configuration commands, one per line. End with CNTL/Z. ATM(config)# interface atm0 ATM(config-if)# atm pvc 10 0 32 aal5snap 45000 ATM(config-if)# atm ds3-scramble ATM(config-if)# atm lbo long ATM(config-if)# atm framing m23adm ATM(config-if)# atm clock internal ATM(config-if)# atm pvc 11 0 34 aal5snap 45000 ATM(config-if)# end ATM#
You can perform all PVC-related configurations for all VLANs on atm0, the major interface, because the subinterface number has no significance for PVC-supported VLANs. VCDs 10 and 11 (used above) can be any unused VCDs. Enter the show atm vc command to find unused VCDs.
Step 9 Bind PVC 1 and PVC 3 to VLAN 5 on Switch 1 by entering these commands:
ATM# configure terminal Enter configuration commands, one per line. End with CNTL/Z. ATM(config)# interface atm0 ATM(config-if)# atm bind pvc vlan 10 5 ATM(config-if)# atm bind pvc vlan 11 5 ATM(config-if)# end ATM#
Enter the VCD numbers used in Step 8. The last option in the atm bind pvc command specifies VLAN 5.
Step 10 Verify the setup on Switch 1 by entering these commands:
ATM# show atm vlan
VCD VLAN-ID
10 5
11 5
ATM#
ATM# show atm vc
AAL/ Peak Avg. Burst
Interface VCD VPI VCI Type Encapsulation Kbps Kbps Cells Status
ATM0 10 0 32 PVC AAL5-SNAP 45000 0 0 ACTIVE
ATM0 11 0 34 PVC AAL5-SNAP 45000 0 0 ACTIVE
ATM#
Step 11 Save the configuration as follows:
ATM# write memory Building configuration... [OK] ATM#
Step 12 At the console of the Catalyst 5000 series Switch 2, establish a connection to the ATM module in slot 2 by entering these commands:
Console> enable Enter password: Console> (enable) set vlan 5 Console> (enable) session 2 Trying ATM-2... Connected to ATM-2. Escape character is '^]'. ATM#
Step 13 Configure PVC 1 and PVC 2 on Switch 2 by entering these commands:
ATM> enable ATM# configure terminal Enter configuration commands, one per line. End with CNTL/Z. ATM(config)# interface atm0 ATM(config-if)# atm pvc 10 0 32 aal5snap 45000 ATM(config-if)# atm ds3-scramble ATM(config-if)# atm lbo long ATM(config-if)# atm framing m23adm ATM(config-if)# atm clock internal ATM(config-if)# atm pvc 11 0 33 aal5snap 2080 ATM(config-if)# end ATM#
You can perform all PVC-related configurations for all VLANs on atm0, the major interface, because the subinterface number has no significance for PVC-supported VLANs. VCDs 10 and 11 (used above) can be any unused VCDs. Enter the show atm vc command to find unused VCDs.
Step 14 Bind PVC 1 and PVC 2 to VLAN 5 on Switch 2 by entering these commands:
ATM# configure terminal Enter configuration commands, one per line. End with CNTL/Z. ATM(config)# interface atm0 ATM(config-if)# atm bind pvc vlan 10 5 ATM(config-if)# atm bind pvc vlan 11 5 ATM(config-if)# end ATM#
Enter the VCDs used in Step 13. The last option in the atm bind pvc command specifies VLAN 5.
Step 15 Verify the setup on Switch 2 by entering these commands:
ATM# show atm vlan
VCD VLAN-ID
10 5
11 5
ATM#
ATM# show atm vc
AAL / Peak Avg. Burst
Interface VCD VPI VCI Type Encapsulation Kbps Kbps Cells Status
ATM0 10 0 32 PVC AAL5-SNAP 45000 0 0 ACTIVE
ATM0 11 0 33 PVC AAL5-SNAP 2080 0 0 ACTIVE
ATM#
Step 16 Save the configuration as follows:
ATM# write memory Building configuration... [OK] ATM#
Step 17 At the console of the Catalyst 5000 series Switch 3, establish a connection to the ATM module in slot 2 by entering these commands:
Console> enable Enter password: Console> (enable) set vlan 5 Console> (enable) session 2 Trying ATM-2... Connected to ATM-2. Escape character is '^]'. ATM>
Step 18 Configure PVC 2 and PVC 3 on Switch 3 by entering these commands:
ATM> enable ATM# configure terminal Enter configuration commands, one per line. End with CNTL/Z. ATM(config)# interface atm0 ATM(config-if)# atm pvc 10 0 33 aal5snap 2080 ATM(config-if)# atm pvc 11 0 34 aal5snap 45000 ATM(config-if)# end ATM#
You can perform all PVC-related configurations for all VLANs on atm0, the major interface, because the subinterface number has no significance for PVC-supported VLANs. VCDs 10 and 11 (used above) can be any unused VCDs. Enter the show atm vc command to find unused VCDs.
Step 19 Bind PVC 2 and PVC 3 to VLAN 5 on Switch 3 by entering these commands:
ATM# configure terminal Enter configuration commands, one per line. End with CNTL/Z. ATM(config)# interface atm0 ATM(config-if)# atm bind pvc vlan 10 5 ATM(config-if)# atm bind pvc vlan 11 5 ATM(config-if)# end ATM#
Enter the VCDs used in Step 18. The last option in the atm bind pvc command specifies VLAN 5.
Step 20 Verify the setup on Switch 3 by entering these commands:
ATM# show atm vlan
VCD VLAN-ID
10 5
11 5
ATM#
ATM# show atm vc
AAL / Peak Avg. Burst
Interface VCD VPI VCI Type Encapsulation Kbps Kbps Cells Status
ATM0 10 0 33 PVC AAL5-SNAP 2080 0 0 ACTIVE
ATM0 11 0 34 PVC AAL5-SNAP 45000 0 0 ACTIVE
ATM#
Step 21 Save the configuration as follows:
ATM# write memory Building configuration... [OK] ATM#
Figure 36-3 shows the PVCs needed for complete redundancy if PHY A or PHY B on either Switch 1 or Switch 2 fails. This example (referred to as example 2) applies to the dual PHY DS3 module, but you can use the same configuration for dual PHY OC-3 modules (with appropriate PCRs).

In Figure 36-3, you see Catalyst 5000 series Switch 1 and Catalyst 5000 series Switch 2, each with an ATM dual PHY DS3 module, connected to a LightStream 1010 ATM switch in the ATM cloud.
Assume PHY A on Switch 1 goes down and transmits no data to PHY A on Switch 2 over PVC 1, even though PHY A on Switch 2 remains active. When PHY A on Switch 1 goes down, PHY B on Switch 1 becomes active and transmits data to PHY B on Switch 2 over PVC 2.
Similarly, if PHY A on Switch 2 goes down and transmits no data to Switch 1 over PVC 1, PHY B on Switch 2 becomes active and transmits data to PHY B on Switch 1 over PVC 3.
Table 36-4 shows the PVCs used to transmit data when the specified PHYs for the Catalyst 5000 series switches in Figure 36-3 are active. For example, if PHY A on Switch 1 and PHY A on Switch 2 are both active, data is transmitted on PVC 1.
| Switch 1 | Switch 2 | PVC Used |
|---|---|---|
PHY A--- active | PHY A--- active | 1 |
PHY A--- active | PHY B--- active | 2 |
PHY B--- active | PHY A--- active | 3 |
PHY B--- active | PHY B--- active | 4 |
The following assumptions apply for this example configuration:
| PVC | Switch Connections | VPI | VCI | kbps Rate |
|---|---|---|---|---|
1 | Connects PHY A on Switch 1 to PHY A on Switch 2 | 0 | 32 | 45000 |
2 | Connects PHY A on Switch 1 to PHY B on Switch 2 | 0 | 33 | 45000 |
3 | Connects PHY B on Switch 1 to PHY A on Switch 2 | 0 | 34 | 45000 |
4 | Connects PHY B on Switch 1 to PHY B on Switch 2 | 0 | 35 | 45000 |
Before configuring the VLAN over PVCs, you must perform these tasks:
To configure the devices in this example, follow these steps:
Step 1 Create PVC 1 within the ATM cloud. Enter these commands on the LightStream 1010 ATM switch:
Switch> enable Switch# configure terminal Enter configuration commands, one per line. End with CNTL/Z. Switch(config)# interface atm0/0/0 Switch(config-if)# atm pvc 0 32 int atm0/0/2 0 32 Switch(config-if)# end Switch#
Step 2 Verify the setup of PVC 1. Enter this command on the LightStream 1010 ATM switch:
Switch# show atm vc interface atm0/0/0 Interface VPI VCI Type X-Interface X-VPI X-VCI Status ATM0/0/0 0 5 PVC ATM2/0/0 0 32 UP ATM0/0/0 0 16 PVC ATM2/0/0 0 33 UP ATM0/0/0 0 18 PVC ATM2/0/0 0 34 UP ATM0/0/0 0 32 PVC ATM0/0/2 0 32 UP Switch#
Step 3 Create PVC 2 within the ATM cloud. Enter these commands on the LightStream 1010 ATM switch:
Switch# configure terminal Enter configuration commands, one per line. End with CNTL/Z. Switch(config)# interface atm0/0/2 Switch(config-if)# atm pvc 0 33 int atm0/0/1 0 33 Switch(config-if)# end Switch#
Step 4 Verify the setup of PVC 2. Enter this command on the LightStream 1010 ATM switch:
Switch# show atm vc interface atm0/0/2 Interface VPI VCI Type X-Interface X-VPI X-VCI Status ATM0/0/2 0 5 PVC ATM2/0/0 0 38 UP ATM0/0/2 0 16 PVC ATM2/0/0 0 39 UP ATM0/0/2 0 18 PVC ATM2/0/0 0 40 UP ATM0/0/2 0 32 PVC ATM0/0/0 0 32 UP ATM0/0/2 0 33 PVC ATM0/0/1 0 33 UP Switch#
Step 5 Create PVC 3 within the ATM cloud. Enter these commands on the LightStream 1010 ATM switch:
Switch# configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)# interface atm0/0/3
Switch(config-if)# atm pvc 0 34 int atm0/0/0 0 34
Switch(config-if)# end
Switch#
Step 6 Verify the setup of PVC 3. Enter this command on the LightStream 1010 ATM switch:
Switch# show atm vc interface atm0/0/3 Interface VPI VCI Type X-Interface X-VPI X-VCI Status ATM0/0/3 0 5 PVC ATM2/0/0 0 41 UP ATM0/0/3 0 16 PVC ATM2/0/0 0 42 UP ATM0/0/3 0 18 PVC ATM2/0/0 0 43 UP ATM0/0/3 0 34 PVC ATM0/0/0 0 34 UP Switch#
Step 7 Create PVC 4 within the ATM cloud. Enter these commands on the LightStream 1010 ATM switch:
Switch# configure terminal Enter configuration commands, one per line. End with CNTL/Z. Switch(config)# interface atm0/0/1 Switch(config-if)# atm pvc 0 35 interface atm0/0/3 0 35 Switch(config-if)# end Switch#
Step 8 Verify the setup of PVC 4. Enter this command on the LightStream 1010 ATM switch:
Switch# show atm vc interface atm0/0/1 Interface VPI VCI Type X-Interface X-VPI X-VCI Status ATM0/0/1 0 5 PVC ATM2/0/0 0 35 UP ATM0/0/1 0 16 PVC ATM2/0/0 0 36 UP ATM0/0/1 0 18 PVC ATM2/0/0 0 37 UP ATM0/0/1 0 33 PVC ATM0/0/2 0 33 UP ATM0/0/1 0 35 PVC ATM0/0/3 0 35 UP Switch#
Step 9 At the console of the Catalyst 5000 series Switch 1, session to the ATM module in slot 2 by entering these commands:
Console> enable Enter password: Console> (enable) session 2 Trying ATM-2... Connected to ATM-2. Escape character is '^]'. ATM>
Step 10 Configure PVCs 1, 2, 3, and 4 on Switch 1 by entering these commands:
ATM> enable ATM# configure terminal Enter configuration commands, one per line. End with CNTL/Z. ATM(config)# interface atm0 ATM(config-if)# atm pvc 1 0 32 aal5snap 45000 ATM(config-if)# atm ds3-scramble ATM(config-if)# atm lbo long ATM(config-if)# atm framing m23adm ATM(config-if)# atm clock internal ATM(config-if)# atm pvc 2 0 33 aal5snap 45000 ATM(config-if)# atm pvc 3 0 34 aal5snap 45000 ATM(config-if)# atm pvc 4 0 35 aal5snap 45000 ATM(config-if)# end ATM#
You can perform all PVC-related configurations for all VLANs on atm0, the major interface, because the subinterface number has no significance for PVC-supported VLANs. VCDs 10 and 11 (used above) can be any unused VCDs. Enter the show atm vc command to find unused VCDs.
Step 11 Bind the PVCs to VLAN 5 on the Switch 1 by entering these commands:
ATM# configure terminal Enter configuration commands, one per line. End with CNTL/Z. ATM(config)# interface atm0 ATM(config-if)# atm bind pvc vlan 1 5 ATM(config-if)# atm bind pvc vlan 2 5 ATM(config-if)# atm bind pvc vlan 3 5 ATM(config-if)# atm bind pvc vlan 4 5 ATM(config-if)# end ATM#
Enter the VCD numbers used in Step 8. The last option in the atm bind pvc command specifies VLAN 5.
Step 12 Verify the setup on the Switch 1 by entering these commands:
ATM# show atm vlan
VCD VLAN-ID
1 5
2 5
3 5
4 5
ATM#
ATM# show atm vc
AAL / Peak Avg. Burst
Interface VCD VPI VCI Type Encapsulation Kbps Kbps Cells Status
ATM0 1 0 32 PVC AAL5-SNAP 45000 0 0 ACTIVE
ATM0 2 0 33 PVC AAL5-SNAP 45000 0 0 ACTIVE
ATM0 3 0 34 PVC AAL5-SNAP 45000 0 0 ACTIVE
ATM0 4 0 35 PVC AAL5-SNAP 45000 0 0 ACTIVE
ATM#
Step 13 Save the configuration as follows:
ATM# write memory Building configuration... [OK] ATM#
Step 14 At the console of the Catalyst 5000 series Switch 2, session to the ATM module in slot 2 by entering these commands:
Console> enable Enter password: Console> (enable) set vlan 5 Console> (enable) session 2 Trying ATM-2... Connected to ATM-2. Escape character is '^]'. ATM>
Step 15 Configure PVCs 1, 2, 3, and 4 on Switch 2 by entering these commands:
ATM> enable ATM# configure terminal Enter configuration commands, one per line. End with CNTL/Z. ATM(config)# interface atm0 ATM(config-if)# atm pvc 1 0 32 aal5snap 45000 ATM(config-if)# atm ds3-scramble ATM(config-if)# atm lbo long ATM(config-if)# atm framing m23adm ATM(config-if)# atm clock internal ATM(config-if)# atm pvc 2 0 33 aal5snap 45000 ATM(config-if)# atm pvc 3 0 34 aal5snap 45000 ATM(config-if)# atm pvc 4 0 35 aal5snap 45000 ATM(config-if)# end ATM#
You can perform all PVC-related configurations for all VLANs on atm0, the major interface, because the subinterface number has no significance for PVC-supported VLANs. VCDs 10 and 11 (used above) can be any unused VCDs. Enter the show atm vc command to find unused VCDs.
Step 16 Bind the PVCs to VLAN 5 on the Catalyst 5000 series Switch 2 by entering these commands:
ATM# configure terminal Enter configuration commands, one per line. End with CNTL/Z. ATM(config)# interface atm0 ATM(config-if)# atm bind pvc vlan 1 5 ATM(config-if)# atm bind pvc vlan 2 5 ATM(config-if)# atm bind pvc vlan 3 5 ATM(config-if)# atm bind pvc vlan 4 5 ATM(config-if)# end ATM#
Step 17 Verify the setup on the Catalyst 5000 series Switch 2 by entering these commands:
ATM# show atm vlan
VCD VLAN-ID
1 5
2 5
3 5
4 5
ATM#
ATM# show atm vc
AAL / Peak Avg. Burst
Interface VCD VPI VCI Type Encapsulation Kbps Kbps Cells Status
ATM0 1 0 32 PVC AAL5-SNAP 45000 0 0 ACTIVE
ATM0 2 0 33 PVC AAL5-SNAP 45000 0 0 ACTIVE
ATM0 3 0 34 PVC AAL5-SNAP 45000 0 0 ACTIVE
ATM0 4 0 35 PVC AAL5-SNAP 45000 0 0 ACTIVE
ATM#
Step 18 Save the configuration as follows:
ATM# write memory Building configuration... [OK] ATM#
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Tue Mar 30 16:11:11 PST 1999
Copyright 1989-1999©Cisco Systems Inc.