Use the show port broadcast command to display broadcast information.
show port broadcast [mod_num[/port_num]]
mod_num | (Optional) Number of the module. If you do not specify a number, the ports on all modules are shown. |
/port_num | (Optional) Number of the port on the module. If you do not specify a number, all the ports on the module are shown. |
This command has no default setting.
Switch command.
Normal.
On the 1000BaseX switching module, when you specify a port for broadcast suppression, the traffic is suppressed only in the network-to-Catalyst 5000, 2926G, and 2926 series switches bus direction.
This command is not supported by the Catalyst 4000 and 2948G series switches.
This example shows how to display broadcast information for port 2 on module 1:
Console> show port broadcast 1/2 Port Broadcast-Limit Broadcast-Drop -------- --------------- -------------- 1/2 -- 1/2 - - Console>
Table 2-49 describes the possible fields in the show port broadcast command output.
| Field | Description |
|---|---|
Port | Module and port number. |
Broadcast-Limit | Broadcast threshold configured for the port. |
Broadcast-Drop | Number of broadcast/multicast packets dropped because the broadcast limit for the port was exceeded. |
Use the show port capabilities command to display the capabilities of the modules and ports in a switch.
show port capabilities [mod_num[/port_num]]
mod_num | (Optional) Number of the module. |
/port_num | (Optional) Number of the port on the module. |
This command has no default setting.
Switch command.
Normal.
If you do not specify a mod_num, the ports on all modules are shown.
If you do not specify a /port_num, all the ports on the module are shown.
The Catalyst 2948G is a fixed configuration switch. All ports are located on module 2; for this reason, if you enter mod_num/port_num 1/N, an error message will be displayed.
This example shows how to show the port capabilities for module 1, port 1:
Console> (enable) show port capabilities 1/1 Model WS-X5509 Port 1/1 Type 100BaseTX Speed 100 Duplex half,full Trunk encap type ISL Trunk mode on,off,desirable,auto,nonegotiate Channel 1/1-2 Broadcast suppression percentage(0-100) Flow control no Security yes Membership static,dynamic Fast start yes Rewrite no Console> (enable)
Table 2-50 describes the possible fields (depending on the type of port queried) and the values in the show port capabilities command output.
| Field | Description |
|---|---|
Model | Module model number. |
Port | Module number and port number. |
Type1 | Port type, for example, 100BaseFX MM, 100BaseFX SM, or 10/100BaseTX. |
Speed1 | Port speed setting (for example, auto, 100, or 1000). |
Duplex | Duplex mode (half, full, auto, fdx, hdx, or no). |
Trunk encap type | Trunk encapsulation type (ISL, 802.1Q, 802.10, or no). |
Trunk mode | Trunk administrative status of the port (on, off, auto, desirable, nonegotiate, or no). |
Channel | Status of which ports can form a channel group. The ports are shown in mod_num/port_num format. For example, 3/1-2 indicates module 3, ports 1 and 2. Also, any ports in range [mod/1-mod/high_port] or no ports may be indicated. |
Broadcast suppression | Number of packets-per-second (pps) of broadcast/multicast traffic allowed on the port (0-150000) or the percentage of total available bandwidth that can be used by broadcast/multicast traffic (0-100). |
Flow control | Flow-control options you can set (receive-[off, on, desired], send-[off, on, desired], or no). |
Security | Status of whether port security is enabled (yes, no). |
Membership | Method of membership assignment of a port or range of ports to a VLAN (static, dynamic). |
Fast Start | Status of whether the spanning-tree port fast-start feature on the port is enabled (yes, no). |
Rewrite | Status of whether the port supports inline rewrite (yes, no). |
| 1These fields will change depending on the system configuration. |
set port channel
set port broadcast
set port security
set port speed
set spantree portfast
set trunk
Use the show port cdp command to display port CDP enable state and message interval on the port.
show port cdp [mod_num[/port_num]]
mod_num | (Optional) Number of the module. |
/port_num | (Optional) Number of the port on the module. |
This command has no default setting.
Switch command.
Normal.
If you do not specify a mod_num, the ports on all modules are shown. If you do not specify a /port_num, all the ports on the module are shown.
The Catalyst 2948G is a fixed configuration switch. All ports are located on module 2; for this reason, if you enter mod_num/port_num 1/N, an error message will be displayed.
This example shows how to display CDP information for all ports:
Console> show port cdp Port CDP Status Message-Interval -------- ---------- ---------------- 1/1 enabled 60 1/2 enabled 60 2/1 enabled 60 3/1 enabled 60 Console>
Table 2-51 describes the fields in the show port cdp command output.
| Field | Description |
|---|---|
Port | Module and port number. |
CDP Status | CDP status of the port (enabled, disabled). |
Message-Interval | Interval between CDP message exchange with neighbor. |
Use the show port channel command to display EtherChannel information for a specific module or port.
show port channel [mod] [info | statistics]
mod | (Optional) Number of the module. |
info | (Optional) Keyword to display port information such as speed, cost, duplex status, priority, secure or dynamic status, trunk status, and associated VLANs. |
statistics | (Optional) Keyword to display statistics about the port (PAgP packets sent and received). |
mod/port | Number of the module and port. |
This command has no default setting.
Switch command.
Normal.
If mod or mod/port is not specified, EtherChannel information is shown for all channeling ports on all modules.
This command is not supported by the three-port Gigabit Ethernet switching module (WS-X5403).
The Catalyst 2948G is a fixed configuration switch. All ports are located on module 2; for this reason, if you enter mod/port 1/N, an error message will be displayed.
This example shows how to display Ethernet channeling information for Fast Ethernet module 4:
Console> show port channel 4
Port Status Channel Channel Neighbor Neighbor
mode status device port
----- ---------- ------- ----------- ------------------------- ----------
4/1 connected on channel WS-C5000 012345678 5/5
4/2 connected on channel WS-C5000 012345678 5/6
----- ---------- ------- ----------- ------------------------- ----------
4/3 connected off not channel
4/4 connected off not channel
4/5 notconnect desirable not channel
4/6 notconnect desirable not channel
4/7 notconnect desirable not channel
4/8 notconnect desirable not channel
----- ---------- ------- ----------- ------------------------- ----------
4/9 connected on channel WS-C5000 987654321 3/1
4/10 connected on channel WS-C5000 987654321 3/2
4/11 notconnect on channel
4/12 connected on channel WS-C5000 987654321 3/4
----- ---------- ------- ----------- ------------------------- ----------
Console>
This example shows show port channel with the statistics parameter:
Console> show port channel 1 statistics
Port PAgP Pkts PAgP Pkts
Transmitted Received
----- ----------- ---------
1/1 0 0
1/2 0 0
Console>
This example shows show port channel with the info parameter:
>Console> show port channel 5/1 info >Port Speed Duplex Vlan Port Secure port\ Trunk status VLANs > priority Dynamic port >----- ----- ------ ---- -------- ------------ ------------ ------------------ > > 5/1 a-100 a-full 1 32 trunking 1-1005 > 5/2 a-100 a-full 1 32 trunking 1-1005 >----- ----- ------ ---- -------- ------------ ------------ ------------------ > >Port ifIndex Group Neighbor Neighbor Neighbor > capability device-id port-id capability >----- ---------- ---------- ----------------- -------- ---------- > 5/1 530 1 00-e0-1e-52-1a-44 17 1 > 5/2 530 1 00-e0-1e-52-1a-44 18 1 >----- ---------- ---------- ----------------- -------- ---------- Console>
Table 2-52 describes the possible fields (depending on the type of port queried) and the values in the show port channel command output.
| Field | Description |
|---|---|
Port | Module and port number. |
Status | Channeling status of the port (connected, notconnect). |
Channel mode | Status of whether EtherChannel is on, off, auto, or desirable on the port. |
Channel status | Status of whether the port is channeling (channel, not channel). |
Neighbor device | Neighboring device with which the port is channeling. |
Neighbor port | Port on the neighboring device with which the port is channeling. |
Speed | Speed setting for the port. |
Duplex | Duplex setting for the port (auto, full, fdx, half, hdx, a-half, a-hdx, a-full, or a-fdx). |
Vlan | VLAN to which the port belongs. |
Port priority | Priority associated with the port. |
Secure port/Dynamic port | Status of whether the port is secure or dynamic. |
Trunk status | Status of whether the port is trunking or not. |
VLANs | VLANs to which the port belongs. |
ifIndex | Interface number to which the port belongs. |
Group capability | Capability of the group. |
Neighbor device-id | Device ID of the neighboring device with which the port is channeling. |
Neighbor port-id | Port ID of the neighboring device with which the port is channeling. |
Neighbor capability | Capability of the neighboring device. |
PAgP Pkts Transmitted | Number of PAgP packets transmitted. |
PAgP Pkts Received | Number of PAgP packets received. |
Use the show port counters command to show all the counters for a port.
show port counters [mod_num/port_num]
mod_num | (Optional) Number of the module for which to show port counter information. |
/port_num | (Optional) Number of the port on the module for which to show port counter information. |
This command has no default setting.
Switch command.
Normal.
If you do not specify a mod_num, the ports on all modules are shown.
If you do not specify a /port_num, all the ports on the module are shown.
The Catalyst 2948G is a fixed configuration switch. All ports are located on module 2; for this reason, if you enter mod_num/port_num 1/N, an error message will be displayed.
This example shows the output of the show port counters command:
Console> show port counters
Port Align-Err FCS-Err Xmit-Err Rcv-Err UnderSize
----- ---------- ---------- ---------- ---------- ---------
1/1 0 0 0 0 0
1/2 0 0 0 0 0
4/1 0 0 0 0 0
4/2 0 0 0 0 0
4/3 0 0 0 0 0
4/4 0 0 0 0 0
Port Single-Col Multi-Coll Late-Coll Excess-Col Carri-Sen Runts Giants
----- ---------- ---------- ---------- ---------- --------- --------- ---------
1/1 12 0 0 0 0 0 -
1/2 0 0 0 0 0 0 0
4/1 0 0 0 0 0 0 0
4/2 0 0 0 0 0 0 0
4/3 0 0 0 0 0 0 0
4/4 0 0 0 0 0 0 0
Ler
Port CE-State Conn-State Type Neig Con Est Alm Cut Lem-Ct Lem-Rej-Ct Tl-Min
----- -------- ---------- ---- ---- --------------- ---------- ---------- ------
3/1 isolated connecting A U no 9 9 7 0 0 102
3/2 isolated connecting B U no 9 8 7 0 0 40
Last-Time-Cleared
--------------------------
Fri Aug 11 1998, 14:58:19
Table 2-53 describes the possible fields (depending on the port type queried) in the show port counters command output.
| Field | Description |
|---|---|
Port | Module and port number. |
Align-Err | Number of frames with alignment errors (frames that do not end with an even number of octets and have a bad CRC) received on the port. |
FCS-Err | Number of frame check sequence errors that occurred on the port. |
Xmit-Err | Number of transmit errors that occurred on the port (indicating that the internal transmit buffer is full). |
Rcv-Err | Number of receive errors that occurred on the port (indicating that the internal receive buffer is full). |
UnderSize | Number of received frames less than 64 octets long (but are otherwise well formed). |
Single-Coll | Number of times one collision occurred before the port successfully transmitted a frame to the media. |
Multi-Coll | Number of times multiple collisions occurred before the port successfully transmitted a frame to the media. |
Late-Coll | Number of late collisions (collisions outside the collision domain). |
Excess-Col | Number of excessive collisions that occurred on the port (indicating that a frame encountered 16 collisions and was discarded). |
Carri-Sen | Number of times the port sensed a carrier (to determine whether the cable is currently being used). |
Runts | Number of received runt frames (frames that are smaller than the minimum IEEE 802.3 frame size) on the port. |
Giants | Number of received giant frames (frames that exceed the maximum IEEE 802.3 frame size) on the port. |
CE-State | Connection entity status. |
Conn-State | Connection state of the port, as follows:
|
Type | Type of port, such as A---A port and B---B port. |
Neig | Type of port attached to this port. The neighbor can be one of these types:
|
Ler Con | Status of whether the port is currently in a LER condition. |
Est | Estimated LER. |
Alm | LER at which a link connection exceeds the LER alarm threshold. |
Cut | LER cutoff value (the LER at which a link connection is flagged as faulty). |
Lem-Ct | Number of LEM errors received on the port. |
Lem-Rej-Ct | Number of times a connection was rejected because of excessive LEM errors. |
Tl-Min | TL-min value (the minimum time to transmit a FDDI PHY line state) before advancing to the next PCM state. |
Last-Time-Cleared | Last time the port counters were cleared. |
Use the show port filter command to view MAC addresses and protocol filters that have been configured on the Token Ring module ports.
show port filter [mod_num] [canonical]
mod_num | (Optional) Number of the module. |
canonical | (Optional) Keyword to specify the MAC address display in canonical format. |
/port_num | Number of the port on the module. |
mac_addr | MAC address contained in the packets to be filtered. You need to enter this address in canonical format (00-11-33-44-55) or in noncanonical format (00:11:22:33:44:55). |
By default, MAC addresses are shown in noncanonical format.
Switch command.
Normal.
This command is not supported on the Catalyst 4000 and 2948G series switches.
This example shows how to display the filters configured for a port on the Token Ring module:
Console> show port filter 3/1
Port Mac-Addr Type
----- ----------------- ------
3/1 00:00:00:00:00:00 deny
00:00:00:00:00:00 deny
00:00:00:00:00:00 deny
00:00:00:00:00:00 deny
00:00:00:00:00:00 deny
00:00:00:00:00:00 deny
Port Protocol Type
----- ----------------- ------
3/1 0x8038 deny
0xf0f0 deny
Table 2-54 describes the fields in the show port filter command output.
| Field | Description |
|---|---|
Port | Module and port number. |
MAC-Addr | MAC address contained in packets to be filtered. |
Type | Type of MAC address filter configured. Possible types are deny (block any packet containing a specific MAC address) or permit (allow any packet containing a specific MAC address). |
Protocol | Types of protocols that you want to filter. |
Type | Type of protocol filter configured. Possible types are deny (block any packet containing a specific protocol type) or permit (allow any packet containing a specific protocol type). |
clear port filter
set port filter
Use the show port flowcontrol command to display per-port status information and statistics related to flow control.
show port flowcontrol [mod_num[/port_num]]
mod_num | (Optional) Number of the module. |
/port_num | (Optional) Number of the port on the module. If you do not specify a number, filters configured on all the ports on the module are shown. |
This command has no default setting.
Switch command.
Normal.
The Catalyst 2948G is a fixed configuration switch. All ports are located on module 2; for this reason, if you enter mod_num/port_num 1/N, an error message will be displayed.
This example shows how to display the flow-control port status and statistics:
Console> show port flowcontrol PortSend-FlowcontrolReceive-FlowcntlRxPauseTxPause AdminOperAdminOper ----- --------------------------------------------- 3/1ondisagreeondisagree00 3/2 offoffoffoff00 3/3desiredondesired off1010
Table 2-55 describes the fields in the show port flowcontrol command output.
| Field | Description |
|---|---|
Port | Module and port number. |
Send-Flowcontrol | Flow-control administration. Possible settings: on indicates the local port sends flow control to the far end; off indicates the local port does not send flow control to the far end; desired indicates the local end sends flow control to the far end if the far end supports it. |
Send-Flowcontrol | Flow-control operation. Possible setting: disagree indicates the two ports could not agree on a link protocol. |
Receive-Flowcntl | Flow-control administration. Possible settings: on indicates the local port requires the far end to send flow control; off indicates the local port does not allow the far end to send flow control; desired indicates the local end allows the far end to send flow control. |
Receive-Flowcntl | Flow-control operation. Possible setting: disagree indicates the two ports could not agree on a link protocol. |
RxPause | Number of Pause frames received. |
TxPause | Number of Pause frames transmitted. |
Use the show port ifindex command to view IfIndex information on a per-port or per-module basis.
show port ifindex [mod_num]
mod_num | (Optional) Number of the module. |
port_num | Number of the port. |
This command has no default settings.
Switch command.
Normal.
The Catalyst 2948G is a fixed configuration switch. All ports are located on module 2; for this reason, if you enter mod_num/port_num 1/N, an error message will be displayed.
This example shows how to display IfIndex information for all the ports:
Console> show port ifindex Port ifIndex ----- ------- 1/1 3 1/2 4 3/1 383 3/2 384 4/1 385 4/2 386 4/3 387 4/4 388 4/5 389 4/6 390 4/7 391 4/8 392 4/9 393 4/10 394 4/11 395 4/12 396 4/13 397 Console>
Use the show port negotiation command to display the link negotiation protocol setting for the specified port.
show port negotiation [mod_num[/port_num]]
mod_num | (Optional) Number of the module. |
/port_num | (Optional) Number of the port on the module. |
This command has no default setting.
Switch command.
Normal.
The Catalyst 2948G is a fixed configuration switch. All ports are located on module 2; for this reason, if you enter mod_num/port_num 1/N, an error message will be displayed.
This command only applies to Gigabit Ethernet ports.
This example shows how to display the link negotiation protocol settings on module 3, port 1:
Console> show port negotiation 3/1 Port Link Negotiation ------- -------------------- 3/1 enabled Console>
show port flowcontrol
set port negotiation
Use the show port protocol command to view protocol filters configured on the ports.
show port protocol [mod_num[/port_num]]
mod_num | (Optional) Number of the module. |
/port_num | (Optional) Number of the port on the module. |
This command has no default setting.
Switch command.
Normal.
If you do not specify a /port_num, filters configured on all the ports on the module are shown.
The Catalyst 2948G is a fixed configuration switch. All ports are located on module 2; for this reason, if you enter mod_num/port_num 1/N, an error message will be displayed.
This example shows how to view protocol filters on configured ports:
Console> show port protocol Port Vlan IP IP Hosts IPX IPX Hosts Group Group Hosts -------- ---------- -------- -------- -------- --------- -------- ----------- 1/1 1 on 0 on 0 on 0 1/2 1 on 0 on 0 on 0 2/1 1 on 3 auto-on 0 auto-on 0 2/2 1 on 0 on 0 on 0 2/3 1 on 0 on 0 on 0 2/4 1 on 0 on 0 on 0 2/5 1 on 0 on 0 on 0 2/6 1 on 0 on 0 on 0 2/7 1 on 0 on 0 on 0 2/8 1 on 0 on 0 on 0 2/9 1 on 0 on 0 on 0 2/10 1 on 0 on 0 on 0 Console>
Use the show port status command to display port status information.
show port status [mod_num[/port_num]]
mod_num | (Optional) Number of the module. |
/port_num | (Optional) Number of the port on the module. |
This command has no default setting.
Switch command.
Normal.
The Catalyst 2948G is a fixed configuration switch. All ports are located on module 2; for this reason, if you enter mod_num/port_num 1/N, an error message will be displayed.
If you do not specify a mod_num, the ports on all modules are shown.
If you do not specify a /port_num, all the ports on the module are shown.
This example shows how to display port status information for all ports:
Console> show port status Port Name Status Vlan Level Duplex Speed Type ----- ------------------ ---------- ---------- ------ ------ ----- ------------ 1/1 connected 523 normal half 100 100BaseTX 1/2 notconnect 1 normal half 100 100BaseTX 2/1 connected trunk normal half 400 Route Switch 3/1 notconnect trunk normal full 155 OC3 MMF ATM 5/1 notconnect 1 normal half 100 FDDI 5/2 notconnect 1 normal half 100 FDDI Console>
Table 2-56 describes the fields in the show port status command output.
| Field | Description |
|---|---|
Port | Module and port number. |
Name | Name (if configured) of the port. |
Status | Status of the port (connected, notconnect, connecting, standby, faulty, inactive, shutdown, disabled, or monitor). |
Vlan | VLANs to which the port belongs. |
Level | Level setting for the port (normal or high). |
Duplex | Duplex setting for the port (auto, full, fdx, half, hdx, a-half, a-hdx, a-full, or a-fdx). |
Speed | Speed setting for the port (auto, 10, 100,155, a-10, a-100, 4, 16, a-14,or a-16). |
Type1 | Port type, for example, 10BaseT, 10BaseFL MM, 100BaseTX, 100BaseT4, 100BaseFX MM, 100BaseFX SM, 10/100BaseTX, TokenRing, FDDI, CDDI, or RSM. |
| 1These fields will change according to the system configuration. |
Use the show proc command to display CPU, memory allocation, and process utilization information.
show proc [cpu | mem]
cpu | (Optional) Key word to specify CPU information. |
mem | (Optional) Key word to specify malloced memory information. |
This command has no default setting.
Switch command.
Privileged.
This command can only be entered in privileged mode. If you do not specify cpu or mem, process information is displayed.
The mem keyword allows you to display malloced memory information, such as how much memory each process has allocated, and how much it has freed that can be obtained.
This example shows how to display CPU information:
Console> (enable)show proc cpu(W)CPU utilization for five seconds: 1.0%; one minute: 1. 0%; five minutes: 1. %PID Runtime(ms) Invoked uSecs 5Sec 1Min 5min TTY Process0 0 0 0 99.10% 99.0 % 99.0 % 0 idle1 1 36 1000 0.0 % 0.0 % 0.0 % 0 Flash MIB Updat2 1342 2846 460000 0.0 % 0.0 % 0.0 % 0 SynDiags3 730172 4440594 400000 0.0 % 0.0 % 0.0 % 0 SynConfig4 33752 424120 1000 0.0 % 0.0 % 0.0 % 0 Statuspoll5 7413 44916 1000 0.0 % 0.0 % 0.0 % 0 SWPoll64bCnt6 9568 15889836 1000 0.0 % 0.0 % 0.0 % 0 SL_TASK7 746 636118 105000 0.0 % 0.0 % 0.0 % 0 RedundantTask8 933 47 5000 0.0 % 0.0 % 0.0 % 0 ATM/RSM SupportConsole> (enable)
This example shows how to display process information:
Console> (enable)show proc memTotal: 10945712, Used: 1438992, Free: 9506720PID TTY Allocated Freed Holding Process0 0 706240 2832 703408 idle1 0 240 0 240 Flash MIB Updat2 0 164944 164144 800 SynDiags3 0 208224 2992 205232 SynConfig4 0 96 0 96 Statuspoll5 0 2592 2560 32 SWPoll64bCnt6 0 80 0 80 SL_TASK7 0 2272 1952 320 RedundantTask8 0 192384 23600 168784 ATM/RSM SupportConsole> (enable)
This example shows how to display process utilization information:
Console> (enable)show procPID Q T PC Runtime(ms) Invoked uSecs Stacks TTY Process0 1 rd 0x80407b10 0 0 0 1640/6144 0 idle1 65376 st 0x80407d8c 1 36 1000 1188/6144 0 Flash MIB Upda2 2 st 0x80407d8c 1342 2846 460000 3160/6144 0 SynDiags3 1 rd 0x80407d8c 729979 4439406 400000 1672/6144 0 SynConfig4 2 si 0x80407d8c 33739 424007 1000 1572/6144 0 Statuspoll5 4 si 0x80407d8c 7413 44916 1000 1888/6144 0 SWPoll64bCnt6 2 si 0x80407d8c 9565 15885713 1000 1096/6144 0 SL_TASK7 2 si 0x80407d8c 746 635948 105000 1192/6144 0 RedundantTask8 2 st 0x80407d8c 933 47 5000 1824/6144 0 ATM/RSM SupportConsole> (enable)
Table 2-57 describes the possible fields in the show proc command outputs:
| Field | Definition |
|---|---|
CPU Utilization | Sum of all the loads from all the processes running on the CPU in the last 5 seconds, 1 minute, and 5 minutes. |
PID | Process ID. |
Runtime | Time the process has run since getting created (in milliseconds). |
Invoked | Number of times the process was invoked since getting created. |
uSecs | Maximum time a process ran in a single invocation. |
5sec | Percentage of time this process ran on the CPU in the last 5-second interval. |
1Min | Percentage of time this process ran on the CPU in the last 1-minute interval. |
5Min | Percentage of time this process ran on the CPU in the last 5-minute interval. |
TTY | TTY associated with the process. |
Process | Name of the process. |
Allocated | Sum of all the memory malloced by the process since it was created, including the memory previously freed. |
Freed | Sum of memory the process has freed until now. |
Holding | Amount of memory the process is currently holding. |
PC | Calling PC for "show_process" function. |
Q | Process priority in terms of numbers. Low number means high priority. |
T | State of the process (Running, we=waiting for event, st=sleeping, si=sleeping on an interval, rd=ready to run, id=idle, xx=dead/zombie). |
Stacks | Size of the stack used by the process and the total stack size allocated to the process (in bytes). |
Use the show protocolfilter command to list whether protocol filtering is enabled or disabled.
show protocolfilterThis command has no keywords or arguments.
This command has no default setting.
Switch command.
Normal.
This command is not supported by the three-port Gigabit Ethernet switching module (WS-X5403).
This example shows how to display whether protocol filtering is enabled or disabled:
Console> show protocolfilter Protocol filtering is enabled on this switch. Console>
Use the show rif command to display RIF information.
show rif [vlan_num]
vlan_num | (Optional) Number of the VLAN that you want to view RIF information on. |
This command has no default setting.
Switch command.
Normal.
These examples show how to display RIF information for the system and for a VLAN:
Console> show rif MAC VLAN RIF -------------------- -------- -------------------- 00:00:30:e2:cf:00 on 401 via 0610.001a.0020 00:05:77:01:bc:4a on 1020 via 0690.00d1.00e2 00:05:77:01:bc:4b on 1020 via 0690.00d1.00e2 00:05:77:01:bc:48 on 1020 via 0690.00d1.00e2 Console> show rif 401 MAC VLAN RIF -------------------- -------- -------------------- 00:00:30:e2:cf:00 on 401 via 0610.001a.0020 Console>
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Wed Mar 31 08:53:45 PST 1999
Copyright 1989-1999©Cisco Systems Inc.