This chapter describes the different command-line interfaces (CLIs) you use to configure the Catalyst 5000 series switch and modules.
This chapter consists of these sections:
The ROM monitor is a ROM-based program that executes upon platform power-up, reset, or when a fatal exception occurs. The system enters ROM monitor mode if the switch does not find a valid system image, if the nonvolatile RAM (NVRAM) configuration is corrupted, or if the configuration register is set to enter ROM monitor mode. From the ROM monitor mode, you can load a system image manually from Flash memory, from a network server file, or from bootflash.
You can also enter ROM monitor mode by restarting the switch and pressing the Break key during the first 60 seconds of startup.
To access the ROM monitor through a terminal server, you can escape to the Telnet prompt and enter the send break command for your terminal emulation program to break into ROM monitor mode.
Once you are in ROM monitor mode, the prompt changes to rommon>. Use the ? command to see the available ROM monitor commands.
The Catalyst 5000 series switch CLI is a basic command-line interpreter, similar to the UNIX C shell.
These sections describe how to use the Catalyst 5000 series switch CLI:
You can access the CLI through the supervisor engine console port or through a Telnet session.
These sections describe how to access the switch CLI:
To access the switch CLI through the console port, you must connect a console terminal to the console port through an EIA/TIA-232 (RS-232) cable. For complete information on how to connect to the supervisor engine console port, refer to the Catalyst 5000 Series Supervisor Engine Installation Guide.
To access the switch through the console port, perform this task:
| Task | Command |
|---|---|
Step 1 Initiate a connection from the terminal to the Catalyst 5000 series switch console prompt and press Return. |
|
Step 2 At the prompt, enter the system password. The Console> prompt appears, indicating that you have accessed the CLI in normal mode. |
|
Step 3 If necessary, enter privileged mode (you must enter privileged mode to change the switch configuration). | enable |
Step 4 Enter the necessary commands to complete the desired tasks. |
|
Step 5 When finished, exit the session. | exit |
After accessing the switch through the console port, you see this display:
Cisco Systems Console Enter password: Console>
Before you can open a Telnet session to the switch, you must first set the IP address for the switch. For information about setting the IP address, see the "Setting the Switch IP Address" section. The Catalyst 5000 series switch supports up to eight simultaneous Telnet sessions. Telnet sessions disconnect automatically after remaining idle for a configurable time period.
To access the switch CLI from a remote host using Telnet, perform this task:
| Task | Command |
|---|---|
Step 1 From the remote host, enter the telnet command and the name or IP address of the switch you want to access. | telnet {hostname | ip_addr} |
Step 2 At the prompt, enter the password for the CLI. If no password has been configured, press Return. |
|
Step 3 Enter the necessary commands to complete your desired tasks. |
|
Step 4 When finished, exit the Telnet session. | exit |
This example shows how to open a Telnet session to the switch:
unix_host% telnet Catalyst_1
Trying 172.16.10.10...
Connected to Catalyst_1.
Escape character is '^]'.
Cisco Systems Console
Enter password:
Catalyst_1>
These sections describe how to work with the Catalyst 5000 series CLI:
The Catalyst 5000 series switch CLI supports two modes of operation: normal and privileged. Both modes are password protected. Enter normal-mode commands for everyday system monitoring. Enter privileged commands to configure the system and perform basic troubleshooting.
After you log in, the system enters normal mode automatically, which gives you access to normal-mode commands only. You can access privileged mode by entering the enable command followed by the privileged-mode password. To return to normal mode, enter the disable command at the prompt.
This example shows how to enter privileged mode:
Console> enable
Enter Password: Console> (enable)
Switch commands are not case sensitive. You can abbreviate commands and parameters as long as they contain enough letters to be distinguished from any other currently available commands or parameters.
The Catalyst 5000 series switch is a multimodule system. Commands you enter from the CLI might apply to the entire system or to a specific module, port, or VLAN.
Catalyst 5000 series module slots, ports, and VLANs are numbered starting with 1. The supervisor engine module is module 1, residing in the top slot. If your Catalyst 5505 or 5500 switch has a redundant supervisor engine, the supervisor modules reside in slots 1 and 2. On each module, port 1 is the left-most port. To reference a specific port on a specific module, the command syntax is mod_num/port_num. For example, 3/1 denotes module 3, port 1. In some commands, such as set trunk, set cam, and set vlan, you can enter lists of ports and VLANs.
To designate ports, enter the module and port number pairs, separated by commas. To specify a range of ports, use a hyphen (-) between the port numbers. Hyphens take precedence over commas. The following examples show several ways of designating ports:
Example 1. 2/1,2/3 denotes module 2, port 1 and module 2, port 3.
Example 2. 2/1-12 denotes module 2, ports 1 through 12.
Example 3. 2/1-2/12 is the same as Example 2.
Each VLAN is designated by a single number. You specify lists of VLANs the same way you do for ports. Individual VLANs are separated by commas (,); ranges are separated by hyphens (-). In the following example, VLANs 1 through 10 and VLAN 1000 are specified:
1-10,1000
Some commands require a Media Access Control (MAC) address, IP address, or IP alias, which must be designated in a standard format. The MAC address format must be six hexadecimal numbers separated by hyphens, as shown in the following example:
00-00-0c-24-d2-fe
The IP address format is 32 bits, written as 4 octets separated by periods (dotted decimal format) that are made up of a network section, an optional subnet section, and a host section, as shown in the following example:
126.2.54.1
If you have configured IP aliases on the switch, you can use IP aliases in place of the dotted decimal IP address. This is true for most commands that use an IP address, except for commands that define the IP address or IP alias. For information on using IP aliases, see the "Creating and Using IP Aliases" section.
If DNS is configured on the switch, you can use DNS host names in place of IP addresses. For information on configuring DNS, refer to the "Using the Domain Name System" section.
You can scroll through the last 20 commands stored in the history buffer, and enter or edit the command at the prompt. Table 2-1 lists the keyboard shortcuts you can use when entering and editing switch commands.
| Keystroke | Function |
|---|---|
Ctrl-A | Jumps to the first character of the command line. |
Ctrl-B or the left arrow key1 | Moves the cursor back one character. |
Ctrl-C | Escapes and terminates prompts and lengthy tasks. |
Ctrl-D | Deletes the character at the cursor. |
Ctrl-E | Jumps to the end of the current command line. |
Ctrl-F or the right arrow key1 | Moves the cursor forward one character. |
Ctrl-K | Deletes from the cursor to the end of the command line. |
Ctrl-L; Ctrl-R | Repeats current command line on a new line. |
Ctrl-N or the down arrow key1 | Enters next command line in the history buffer. |
Ctrl-P or the up arrow key1 | Enters previous command line in the history buffer. |
Ctrl-U; Ctrl-X | Deletes from the cursor to the beginning of the command line. |
Ctrl-W | Deletes last word typed. |
Esc B | Moves the cursor backward one word. |
Esc D | Deletes from the cursor to the end of the word. |
Esc F | Moves the cursor forward one word. |
Delete key or Backspace key | Erases mistake when entering a command; reenter command after using this key. |
| 1The arrow keys function only on ANSI-compatible terminals such as VT100s. |
The history buffer stores the last 20 commands you entered during a terminal session. History substitution allows you to access these commands without retyping them, by using special abbreviated commands. Table 2-2 lists the history substitution commands.
| Command | Function |
|---|---|
| Repeating recent commands: | |
!! | Repeat the most recent command. |
!-nn | Repeat the nnth most recent command. |
!n | Repeat command n. |
!aaa | Repeat the command beginning with string aaa. |
!?aaa | Repeat the command containing the string aaa. |
| To modify and repeat the most recent command: | |
^aaa^bbb | Replace the string aaa with the string bbb in the most recent command. |
| To add a string to the end of a previous command and repeat it: | |
!!aaa | Add string aaa to the end of the most recent command. |
!n aaa | Add string aaa to the end of command n. |
!aaa bbb | Add string bbb to the end of the command beginning with string aaa. |
!?aaa bbb | Add string bbb to the end of the command containing the string aaa. |
Enter help or ? in normal or privileged mode to see the commands available in those modes. On selected commands, entering help or ? after a command provides additional information, such as a command usage description. Command usage, the help menu, and when appropriate, parameter ranges are provided if you enter a command using the wrong number of arguments or inappropriate arguments. Additionally, appending help or ? to a command category displays a list of commands in that category.
These sections describe how to use the Catalyst 5000 series ATM module CLI:
The ATM modules use a subset of the Cisco IOS software. The Cisco IOS user interface provides access to several different command modes. Each command mode provides a group of related commands.
Cisco IOS software provides two command access modes: user EXEC and privileged EXEC. The user EXEC mode does not require a password and allows you direct access only to the ATM module with which you have established a session. The user EXEC mode commands are a subset of the privileged EXEC mode commands.
The privileged EXEC mode requires a password (the default password is atm). From the privileged level, you can access the six configuration modes: user EXEC, privileged EXEC, global configuration, interface configuration, line configuration, and LAN Emulation (LANE) database configuration. Enter a question mark (?) at the system prompt to display the available commands for the current command mode.
Almost every configuration command has a no form. The no form disables a feature or function. Enter the command without the keyword no to reenable a disabled feature or to enable a feature that is disabled by default. Refer to the Catalyst 5000 Series Command Reference publication for more information about the ATM module commands.
The user interface also provides context-sensitive help on command syntax. For information on how to use the help system, refer to the "Getting Context-Sensitive Help" section. It also describes the command editing and command history features that enable you to recall previous command entries and easily edit command entries.
This example shows how to open a session on an ATM module installed in slot 4:
Console> session 4
Enter Password:
ATM>
This section describes the command modes and functions that allow you to access and operate the ATM module CLI. Table 2-3 lists the command modes, how to access each mode, the prompt you see while you are in that mode, the main uses for each configuration mode, and the method to exit that mode. The prompts listed assume the default name ATM.
| Command Mode | Access Method | Prompt | Exit Method |
|---|---|---|---|
User EXEC | Use the session command in the switch CLI. | ATM> | Enter the logout command. |
Privileged EXEC | From user EXEC mode, enter the enable EXEC command. Enter the enable password at the prompt (default is atm). | ATM# | Enter the disable command. |
Global configuration | From privileged EXEC mode, enter the configure privileged EXEC command. | ATM(config)# | Enter the exit or end command, or press Ctrl-Z. |
Interface configuration | From global configuration mode, enter the interface interface_num command. | ATM (config-if)# | To exit to global configuration mode, enter the end command. To exit to privileged EXEC mode, enter the exit command, or press Ctrl-Z. |
Subinterface configuration | From interface configuration mode, enter the interface sub_interface_num command. | ATM (config-subif)# | To exit to global configuration mode, enter the end command. To exit to privileged EXEC mode, enter the exit command, or press Ctrl-Z. |
Line configuration | From global configuration mode, enter the line line_number command. | ATM (config-line)# | To exit to global configuration mode, enter the exit command. To exit to privileged EXEC mode, enter the end command, or press Ctrl-Z. |
LANE database configuration | From global configuration mode, enter the lane database command. | ATM (config-if)# | To exit to global configuration mode, enter the exit command. To exit to privileged EXEC mode, enter the end command, or press Ctrl-Z. |
After you log in to the ATM module, you are automatically in user EXEC command mode. The user EXEC commands are a subset of the privileged EXEC commands. The user EXEC commands allow you to change terminal settings on a temporary basis, perform basic tests, and list system information.
To list the commands available in user EXEC mode, enter a question mark (?) at the ATM> prompt.
The user-level prompt is as follows:
ATM>
Because many privileged commands set operating parameters, use password protection to restrict access to privileged EXEC mode. The privileged EXEC command set includes those commands in user EXEC mode, as well as the configure command through which you can access the remaining command modes. Privileged EXEC mode also includes high-level testing commands, such as debug.
To access and list the privileged EXEC commands, perform this task:
| Task | Command |
|---|---|
Step 1 Enter privileged EXEC mode. | enable password |
Step 2 List privileged EXEC commands. | ? |
If the system administrator has set a password, you are prompted to enter it before you are allowed access to privileged EXEC mode. The password is not displayed on the screen and is case sensitive. If an enable password has not been set, you can only access privileged EXEC mode from the console. The default password for the ATM module is atm.
This example shows how to access privileged EXEC mode:
ATM> enable
Password: ATM#
From privileged EXEC mode, you can access global configuration mode. For instructions, see the "Accessing Global Configuration Mode" section.
To return from privileged EXEC mode to user EXEC mode, perform this task:
| Task | Command |
|---|---|
Exit privileged EXEC mode and return to user EXEC mode. | disable |
Global configuration commands apply to features that affect the ATM module as a whole. To enter global configuration mode, enter the configure privileged EXEC command. When you enter this command, the privileged EXEC mode prompts you for the source of the configuration commands, as follows:
Configuring from terminal, memory, or network [terminal]?
You can specify either the terminal or NVRAM as the source of configuration commands (refer to the Cisco IOS configuration guide and command reference publications for complete information on Cisco IOS commands). The default is to enter commands from the console terminal. Press Return to enter terminal configuration mode.
To access and list the global configuration commands, perform this task:
| Task | Command |
|---|---|
Step 1 At the console terminal, from privileged EXEC mode, enter global configuration mode. | configure |
Step 2 List the global configuration commands. | ? |
This example shows how to access global configuration mode:
ATM#configure terminal
Enter configuration commands, one per line. End with CNTL/Z. ATM(config)#
To exit global configuration command mode and return to privileged EXEC mode, perform this task using one of these commands:
| Task | Command |
|---|---|
Exit global configuration mode. | exit |
Interface configuration commands modify the operation of the ATM interface. Interface configuration commands always follow an interface global configuration command, which defines the interface type.
To access and list the interface configuration commands, perform this task:
| Task | Command |
|---|---|
Step 1 From global configuration mode, enter interface configuration mode. | interface atm01 |
Step 2 List the interface configuration commands. | ? |
Step 3 From interface configuration mode, enter subinterface configuration mode. | interface atm0.sub_interface_num |
Step 4 List the subinterface configuration commands. | ? |
| 1Always specify ATM interface 0 for the Catalyst 5000 series ATM module. |
This example shows how to access interface configuration mode:
ATM(config)#interface atm0
ATM(config-if)#
This example shows how to access subinterface configuration mode:
ATM(config-if)#interface atm0.1
ATM(config-subif)#
To exit interface configuration mode and return to global configuration mode, perform this task:
| Task | Command |
|---|---|
Exit interface configuration mode. | exit |
To exit global configuration mode and return to privileged EXEC mode, perform this task using one of these commands:
| Task | Command |
|---|---|
Exit global configuration mode. | end |
Line configuration commands modify the operation of a terminal line. Line configuration commands always follow a line command, which defines a line number. These commands change terminal parameter settings either on a line-by-line basis or for a range of lines.
To access and list the virtual terminal line configuration commands, perform this task:
| Task | Command |
|---|---|
Step 1 From global configuration mode, configure a virtual terminal line. | line [vty] line-number [ending-line-number]1 |
Step 2 List the line configuration commands. | ? |
| 1This command is documented in the "Terminal Lines and Modem Support Commands" chapter in the Router Products Command Reference publication. |
This example shows how to enter line configuration mode for virtual terminal line 4:
ATM(config)#line 0 4
ATM(config-line)#
To exit line configuration mode and return to global configuration mode, perform this task:
| Task | Command |
|---|---|
Exit line configuration mode. | exit |
To exit global configuration mode and return to privileged EXEC mode, perform this task using one of these commands:
| Task | Command |
|---|---|
Exit global configuration mode. | end |
This section describes how to perform the following functions:
You can get a list of the associated keywords and arguments for any command by using the context-sensitive help feature.
To get help specific to a command mode, a command, a keyword, or arguments, perform one of these tasks:
| Task | Command |
|---|---|
| help |
| full-help |
| terminal full-help1 |
| abbreviated-command-entry? |
| abbreviated-command-entry<Tab> |
| ? |
| command ? |
| command keyword ? |
| 1This command is documented in the Cisco Access Connection Guide. |
When using context-sensitive help, the space (or lack of a space) before the question mark (?) is significant.
To obtain a list of commands that begin with a particular character sequence, enter the characters immediately followed by the question mark (?). Do not include a space. This form of help completes the word for you.
To list keywords or arguments, enter command syntax help by entering a question mark (?) in place of a keyword or argument. Include a space before the ?. This form of help reminds you which keywords or arguments are applicable based on the command, keywords, and arguments you have already entered.
You can abbreviate commands and keywords by using a number of characters that allow a unique abbreviation. For example, you can abbreviate the show command to sh.
Enter the help command (which is available in any command mode) for a brief description of the help system:
ATM#help
Help may be requested at any point in a command by entering
a question mark '?'. If nothing matches, the help list will
be empty and you must back up until entering a '?' shows the
available options.
Two styles of help are provided:
1. Full help is available when you are ready to enter a
command argument (e.g. 'show ?') and describes each possible
argument.
2. Partial help is provided when an abbreviated argument is entered
and you want to know what arguments match the input
(e.g. 'show pr?'.)
You can enter a partial command name and a question mark (?) to obtain a list of commands beginning with a particular character set. See the "Completing a Partial Command Name" section for more details.
This example shows how context-sensitive help enables you to create an access list from configuration mode. Enter co at the system prompt followed by a question mark (?). Do not leave a space between the last letter and the question mark (?). The system provides the commands that begin with co.
ATM#co?
configure connect copy
Enter the configure command followed by a space and a question mark (?) to list the command's keywords and a brief explanation:
ATM#configure ?
memory Configure from NV memory network Configure from a TFTP network host terminal Configure from the terminal <cr>
An error indicator (^) symbol appears at the point in the command string where you have entered an incorrect command, keyword, or argument. The error location indicator and interactive help system allow you to easily find and correct syntax errors.
This example shows how to use context-sensitive help to determine how to clear an ATM interface. First, check the syntax for the command:
ATM#clear ?
counters Clear counters on one or all interfaces interface Clear the hardware logic on an interface lane lane line Reset a terminal line logging Clear logging buffer tcp Clear a TCP connection or statistics ATM#clear
The help output shows that clear interface is the syntax for clearing an interface. Next, check the syntax for specifying the type of interface:
ATM#clear interface ?
ATM ATM interface Ethernet IEEE 802.3 Null Null interface ATM#clear interface
The help output shows that clear interface atm is the syntax for clearing an ATM interface. Next, check the syntax for specifying the specific ATM interface:
ATM#clear interface atm ?
<0-0> ATM interface number ATM#clear interface atm
The help output shows you must specify the ATM interface number. When you specify the interface correctly, the ATM interface is cleared:
ATM#clear interface atm 0
ATM#
The command history feature keeps a record of commands you have entered and allows you to recall these commands. The functions of the command history feature are as follows:
By default, the system records ten command lines in its history buffer. To set the number of command lines the system records during the current terminal session, perform this task in user EXEC mode:
| Task | Command |
|---|---|
Enable the command history feature for the current terminal session. | terminal history [size number-of-lines]1 |
| 1This command is documented in the Cisco Access Connection Guide. |
The terminal no history size command resets the number of lines saved by history to the default of ten lines.
To configure the number of command lines the system records, perform this task in line configuration mode:
| Task | Command |
|---|---|
Enable the command history feature. | history [size number-of-lines]1 |
| 1The no history command turns off command history for the line. |
To recall commands from the history buffer, perform one of these tasks:
| Task | Key Sequence/Command |
|---|---|
| Press Ctrl-P or the up arrow key1. |
| Press Ctrl-N or the down arrow key1. |
| show history |
| 1The arrow keys function only on ANSI-compatible terminals such as VT100s. |
The command history feature is enabled automatically. To disable it during the current terminal session, perform this task in user EXEC mode:
| Task | Command |
|---|---|
Disable the command history feature for the current session. | terminal no history1 |
| 1This command is documented in the Cisco Access Connection Guide. |
To configure a specific line so that the command history feature is disabled, perform this task in line configuration mode:
| Task | Command |
|---|---|
Configure the line so that the command history feature is disabled. | no history |
Catalyst 5000 series ATM software release 2.3 and above includes an enhanced editing mode that provides a set of editing key functions similar to those of the Emacs editor. You can enter commands in uppercase, lowercase, or a mix of both. Only passwords are case sensitive. You can abbreviate commands and keywords to the number of characters that allow a unique abbreviation.
For example, you can abbreviate the show command to sh. After entering the command at the system prompt, press Return to execute the command.
Although enhanced editing mode is enabled automatically, you can disable it and revert to the editing mode of previous software releases. For more information, see the "Ending a Session" section.
To reenable the enhanced editing mode for the current terminal session, perform this task in user EXEC mode:
| Task | Command |
|---|---|
Enable the enhanced editing features for the current terminal session. | terminal editing1 |
| 1This command is documented in the Cisco Access Connection Guide. |
To reconfigure a specific line in enhanced editing mode, perform this task in line configuration mode:
| Task | Command |
|---|---|
Enable the enhanced editing features. | editing |
Perform one of these tasks to move the cursor around on the command line for corrections or changes:
Press Ctrl-B or Press Ctrl-F or Press Ctrl-A. Press Ctrl-E. Press Esc B. Press Esc F.
Task
Keystrokes
press the left arrow key1.
press the right arrow key1.
1The arrow keys function only on ANSI-compatible terminals such as VT100s.
If you cannot remember a complete command name, press the Tab key to allow the system to complete a partial entry. To do so, perform this task:
| Task | Keystrokes |
|---|---|
Complete a command name. | Enter the first few letters, and press the Tab key. |
If your keyboard does not have a Tab key, press Ctrl-I instead.
In the following example, when you enter the letters conf and press the Tab key, the system provides the complete command:
ATM#conf<Tab>
ATM#configure
If you enter a set of characters that could indicate more than one command, the system beeps to indicate an error. Enter a question mark (?) to obtain a list of commands that begin with that set of characters. Do not leave a space between the last letter and the question mark (?). For example, three commands in privileged mode start with co. To see what they are, enter co? at the privileged EXEC prompt. The system displays all commands that begin with co, as follows:
ATM#co?
configure connect copy
The system provides a buffer that contains the last ten items you deleted. You can recall these items and paste them in the command line by performing this task:
| Task | Keystrokes |
|---|---|
Step 1 Recall the most recent entry in the buffer. | Press Ctrl-Y. |
Step 2 Recall the next buffer entry. | Press Esc Y. |
The buffer contains only the last ten items you have deleted or cut. If you press Esc Y more than ten times, you cycle back to the first buffer entry.
The new editing command set provides a wraparound feature for commands that extend beyond a single line on the screen. When the cursor reaches the right margin, the command line shifts ten spaces to the left. You cannot see the first ten characters of the line, but you can scroll back and check the syntax at the beginning of the command. To scroll back, perform this task:
| Task | Keystrokes |
|---|---|
Return to the beginning of a command line to verify that you have entered a lengthy command correctly. | Press Ctrl-B or the left arrow key repeatedly until you scroll back to the beginning of the command entry, or press Ctrl-A to return directly to the beginning of the line1. |
| 1The arrow keys function only on ANSI-compatible terminals such as VT100s. |
In this example, the lane config-atm-address command entry extends beyond one line. When the cursor reaches the end of the line, the line shifts ten spaces to the left and is redisplayed. The dollar sign ($) indicates that the line scrolled to the left. Each time the cursor reaches the end of the line, the line shifts ten spaces to the left.
ATM(config-subif)#lane config-atm-address 39.000000000000014155551211.080020
ATM(config-subif)#$ -atm-address 39.000000000000014155551211.0800200c1001.00
When you complete the entry, press Ctrl-A to check the complete syntax, and then press Return to execute the command. The dollar sign ($) appears at the end of the line to indicate that the line scrolled to the right:
ATM(config-subif)#lane config-atm-address 39.000000000000014155551211.080020 $
The system assumes your terminal screen is 80 columns wide. If your screen has a different width, enter the terminal width command to tell the router the correct width of your screen.
Use line wrapping with the command history feature to recall and modify previous complex command entries. See the "Recalling Commands" section for information about recalling previous command entries.
Perform one of these tasks to delete command entries if you make a mistake or change your mind:
| Task | Keystrokes |
|---|---|
| Press the Delete or Backspace key. |
| Press Ctrl-D. |
| Press Ctrl-K. |
| Press Ctrl-U or Ctrl-X. |
| Press Ctrl-W. |
| Press Esc D. |
When you use the help facility to list the commands in a particular mode, the list is often longer than the terminal screen can display. In such cases, a ---More--- prompt is displayed at the bottom of the screen. To view the next line or screen, perform these tasks:
| Task | Keystrokes |
|---|---|
| Press the Return key. |
| Press the Spacebar. |
If you enter a command and the system suddenly sends a message to your screen, you can recall your current command line entry. To do so, perform this task:
| Task | Keystrokes |
|---|---|
Redisplay the current command line. | Press Ctrl-L or Ctrl-R. |
If you mistype a command entry, you can transpose the mistyped characters by performing this task:
| Task | Keystrokes |
|---|---|
Transpose the character to the left of the cursor with the character located at the cursor. | Press Ctrl-T. |
You can change words to uppercase or lowercase, or capitalize a set of letters, with simple keystroke sequences:
| Task | Keystrokes |
|---|---|
| Press Esc C. |
| Press Esc L. |
| Press Esc U. |
You can use a particular keystroke as an executable command. Perform this task:
| Task | Keystrokes |
|---|---|
Insert a code to indicate to the system that the keystroke immediately following should be treated as a command entry, not an editing key. | Press Ctrl-V or Esc Q. |
After entering the setup command or other configuration commands, exit the ATM module and quit the session.
To end a session, perform this task:
| Task | Command |
|---|---|
Enter the quit EXEC command. | quit |
The RSM is a full-function router running Cisco IOS software. The Cisco IOS user interface allows you to access several different command modes. Each command mode provides a group of related commands. This section describes how to access and list the commands available in each command mode.
Cisco IOS software has two levels of access to commands: user and privileged. The unprivileged user mode is the user EXEC mode. The privileged mode is the privileged EXEC mode and requires a password. The commands available in user EXEC mode are a subset of the commands available in privileged EXEC mode.
From the privileged EXEC level, you can access global configuration mode and six specific configuration modes: interface, subinterface, line, router, ipx-router, and route-map configuration. Enter a question mark (?) at the system prompt to display a list of commands for each command mode.
Almost every system configuration command has a no form. Enter the no form to disable a feature or function. Enter the command without the keyword no to reenable a disabled feature or enable a feature that is disabled by default. For example, IP routing is enabled by default. Specify the command no ip routing to disable IP routing and specify ip routing to reenable it.
Refer to the Catalyst 5000 Series Route Switch Module Installation and Configuration Note, Catalyst 5000 Series Command Reference, and the Cisco IOS Configuration Fundamental Command Reference publications for more information about the RSM commands.
For a complete description of the commands mentioned in this section, refer to the "User Interface Commands" chapter in the Access and Communication Servers Command Reference publication.
To access an RSM installed in a Catalyst 5000 series switch, enter the session mod_num command at the Console> prompt. The switch responds with the Enter Password prompt. Enter the password for the RSM. The RSM responds with the Router> prompt. At this point, you are in user EXEC command mode, and you have direct access only to the RSM with which you have established a session.
The following example shows how to open a session on an RSM installed in slot 4:
Console> session 4
Enter Password: Router>
When you use the RSM with the Catalyst VIP2, the combination is a double-wide module that occupies two consecutive Catalyst 5505, Catalyst 5000, or Catalyst 5500 slots. The Catalyst VIP2 data and control interface is provided through two ribbon cables. Power to the Catalyst VIP2 is provided through the Catalyst VIP2 backplane connector.
For more information, refer to the Route Switch Module Catalyst VIP2-15 and VIP2-40 Installation and Configuration Note.
This section describes the command modes and functions that allow you to access and operate the RSM CLI.
Table 2-4 lists the command modes, how to access each mode, the prompt you will see while you are in that mode, and the method to exit a mode. The prompts listed assume the default RSM name, Router.
| Command Mode | Access Method | Prompt | Exit Method |
|---|---|---|---|
User EXEC | Log in to RSM. | | Use the logout command. |
Privileged EXEC | From user EXEC mode, use the enable EXEC command. | | To exit back to user EXEC mode, use the disable command. To exit into global configuration mode, use the configure privileged EXEC command. |
Global configuration | From privileged EXEC mode, use the configure privileged EXEC command. | | To exit to privileged EXEC mode, use the exit or end command or press Ctrl-Z. To exit to interface configuration mode, enter an interface configuration command. |
Interface configuration | From global configuration mode, enter by specifying an interface with an interface command. | | To exit to global configuration mode, use the exit command. To exit to privileged EXEC mode, press Ctrl-Z. To exit to subinterface configuration mode, specify a subinterface with the interface command. |
Subinterface configuration | From global configuration mode, specify a subinterface with an interface command. | | To exit to global configuration mode, use the exit command. To exit to privileged EXEC mode, press Ctrl-Z. |
Line configuration | From global configuration mode, enter by specifying a line with a line command. | | To exit to global configuration mode, use the exit command. To exit to privileged EXEC mode, press Ctrl-Z. |
Router configuration | From global configuration mode, enter by issuing a command that begins with router (such as router igrp). | | To exit to global configuration mode, use the exit command. To exit to privileged EXEC mode, press Ctrl-Z. |
IPX-router configuration | From global configuration mode, enter by issuing the ipx routing command, and then a command that begins with ipx router (such as ipx router eigrp). | | To exit to global configuration mode, use the exit command. To exit to privileged EXEC mode, press Ctrl-Z. |
Route-map configuration | From global configuration mode, enter by specifying the route-map command. | | To exit to global configuration mode, use the exit command. To exit to privileged EXEC mode, press Ctrl-Z. |
ROM monitor | From privileged EXEC mode, use the reload EXEC command. Press Break during the first 60 seconds while the system is booting. | | To exit to user EXEC mode, press c to continue. |
After you log in to the RSM, you are automatically in user EXEC command mode. The EXEC commands available at the user level are a subset of those available at the privileged level. In general, the user EXEC commands allow you to establish connections, change terminal settings on a temporary basis, perform basic tests, and list system information.
To list the user EXEC commands, perform this task:
| Task | Command |
|---|---|
List the user EXEC commands. | ? |
The user-level prompt consists of the RSM host name followed by an angle bracket (>):
Router>
You can change the RSM name using the hostname global configuration command described in the "System Management Commands" chapter in the Access and Communication Servers Command Reference publication.
Because many of the privileged commands set operating parameters, privileged access should be password-protected to prevent unauthorized use. The privileged command set includes those commands contained in user EXEC mode, as well as the configure command through which you can access the remaining command modes. Privileged EXEC mode also includes high-level testing commands, such as debug. For details on the debug command, see the Debug Command Reference publication.
To access and list the privileged EXEC commands, perform this task:
| Task | Command |
|---|---|
Step 1 Enter the privileged EXEC mode. | enable [password] |
Step 2 List privileged EXEC commands. | ? |
If the system administrator has set a password, you are prompted to enter it before being allowed access to privileged EXEC mode. The password is not displayed on the screen and is case sensitive. The system administrator uses the enable password global configuration command to set the password that restricts access to privileged mode. This command is described in the "System Management Commands" chapter in the Access and Communication Servers Command Reference publication.
The privileged-level prompt consists of the RSM host name followed by the pound sign (#). (If the RSM was named with the hostname command, that name would appear as the prompt instead of "router.")
router#
From the privileged level, you can access global configuration mode. For instructions, see "Accessing Global Configuration Mode," which follows this section.
To return from privileged EXEC mode to user EXEC mode, perform this task:
| Task | Command |
|---|---|
Move from privileged EXEC mode to user EXEC mode. | disable |
Global configuration commands apply to features that affect the system as a whole. Use the configure privileged EXEC command to enter global configuration mode. When you enter this command, the EXEC prompts you for the source of the configuration commands:
Configuring from terminal, memory, or network [terminal]?
You can then specify either the terminal, NVRAM, or a file stored on a network server as the source of configuration commands (see the "System Image and Configuration File Load Commands" chapter in the Access and Communication Servers Command Reference publication). The default is to enter commands from the terminal console. Pressing the Return key begins this configuration method.
To access and list the global configuration commands, perform this task:
| Task | Command |
|---|---|
Step 1 At the terminal, from the privileged EXEC mode, enter global configuration mode. | configure {terminal | memory | network}1 |
Step 2 List the global configuration commands. | ? |
| 1This command is documented in the "System Image and Configuration File Load Commands" chapter in the Access and Communication Servers Command Reference publication. |
To exit global configuration mode and return to privileged EXEC mode, use one of the following commands:
| Task | Command |
|---|---|
Exit global configuration mode. | exit |
From global configuration mode, you can access seven configuration sublevels: interface, subinterface, line, router, ipx-router, route-map, and ROM monitor configuration commands. These command modes are described in the following sections.
Many features are enabled on a per-interface basis. Interface configuration commands modify the operation of an interface such as a VLAN interface. Interface configuration commands always follow an interface command, which defines the interface type.
To access and list the interface configuration commands, perform this task:
| Task | Command |
|---|---|
Step 1 From global configuration mode, enter interface configuration mode. | interface interface-type interface-number1 |
Step 2 List the interface configuration commands. | ? |
| 1This command is documented in the "Interface Commands" chapter in the Access and Communication Servers Command Reference publication. |
To exit interface configuration mode and return to global configuration mode, enter the exit command. To exit Configuration mode and return to privileged EXEC mode, press Ctrl-Z.
Router configuration commands configure a routing protocol and always follow a router command. To access and list the router configuration commands, perform this task:
| Task | Command |
|---|---|
Step 1 From global configuration mode, enter router configuration mode. | router [keyword]1 |
Step 2 List the router configuration commands. | ? |
| 1This command is documented in the "IP Routing Protocols Commands" chapter in the Access and Communication Servers Command Reference publication. |
To list the available router configuration keywords, enter the router command followed by a space and a question mark (?) at the global configuration prompt:
Router(config)#router ?
bgp Border Gateway Protocol (BGP) egp Exterior Gateway Protocol (EGP) eigrp Enhanced Interior Gateway Routing Protocol (EIGRP) igrp Interior Gateway Routing Protocol (IGRP) isis ISO IS-IS iso-igrp IGRP for OSI networks mobile Mobile routes odr On Demand stub Routes ospf Open Shortest Path First (OSPF) rip Routing Information Protocol (RIP) static Static routes
In the following example, the RSM is configured to support the Routing Information Protocol (RIP). The new prompt is router(config-router)#. Enter a question mark (?) to list router configuration commands.
Router(config)#router rip
Router(config-router)#?
Router configuration commands:
auto-summary Enable automatic network number summarization
default Set a command to its defaults
default-metric Set metric of redistributed routes
distance Define an administrative distance
distribute-list Filter networks in routing updates
exit Exit from routing protocol configuration mode
help Description of the interactive help system
maximum-paths Forward packets over multiple paths
neighbor Specify a neighbor router
network Enable routing on an IP network
no Negate a command or set its defaults
offset-list Add or subtract offset from IGRP or RIP metrics
output-delay Interpacket delay for RIP updates
passive-interface Suppress routing updates on an interface
redistribute Redistribute information from another routing
protocol
timers Adjust routing timers
validate-update-source Perform sanity checks against source address of
routing updates
version Set routing protocol version
The list of commands might vary slightly from this example, depending upon how your RSM has been configured.
To exit router configuration mode and return to global configuration mode, enter the exit command. To exit Configuration mode and return to privileged EXEC mode, press Ctrl-Z.
Internet Packet Exchange (IPX) is a Novell network-layer protocol. To access and list the IPX routing configuration commands, perform this task:
| Task | Command |
|---|---|
Step 1 From global configuration mode, enter IPX-router configuration mode. | ipx router [keyword]1 |
Step 2 List the IPX-Router configuration commands. | ? |
| 1This command is documented in the "Novell IPX Commands" chapter in the Access and Communication Servers Command Reference publication. |
In the following example, IPX RIP routing is configured. The new prompt is Router(config-ipx-router):
Router(config)#ipx router rip
Router(config-ipx-router)#?
To exit IPX-router configuration mode and return to global configuration mode, enter the exit command. To exit Configuration mode and return to privileged EXEC mode, press Ctrl-Z.
Use the Route-Map Configuration mode to configure routing table and source and destination information. To access and list the route-map configuration commands, perform this task:
| Task | Command |
|---|---|
Step 1 From global configuration mode, enter Route-Map Configuration mode. | route-map map-tag [[permit | deny] | [sequence-number]]1 |
Step 2 List the route-map configuration commands. | ? |
| 1This command is documented in the "IP Routing Protocols Commands" chapter in the Access and Communication Servers Command Reference publication. |
In the following example, a route map named arizona1 is configured. The new prompt isRouter(config-route-map). Enter a question mark (?) to list route-map configuration commands.
Router(config)#route-map arizona1
Router(config-route-map)#?
Route Map configuration commands: exit Exit from route-map configuration mode help Description of the interactive help system match Match values from routing table no Negate or set default values of a command set Set values in destination routing protocol
To exit Route-Map Configuration mode and return to global configuration Mode, enter the exit command. To exit Configuration mode and return to privileged EXEC mode, press Ctrl-Z.
If the RSM does not find a valid system image, or if its configuration file is corrupted at startup, the system might enter ROM-monitor mode. From ROM-monitor mode, you can boot the router or perform diagnostic tests.
You can also enter ROM-monitor mode by entering the reload EXEC command and then pressing the Break key during the first 60 seconds of startup. To save changes to the configuration file before reloading, use the copy running-config startup-config command before issuing the reload command.
To access and list the ROM monitor configuration commands, complete the following tasks:
| Task | Command |
|---|---|
Step 1 Enter ROM-monitor mode from privileged EXEC mode. | reload1 |
Step 2 List the ROM monitor commands. | ? |
| 1This command is documented in the "System Image and Configuration File Load Commands" chapter of the Access and Communication Servers Command Reference publication. |
The ROM monitor prompt is an angle bracket (>). The following example shows how to list the ROM monitor commands.
> ?
$ state Toggle cache state (? for help)
B [filename] [TFTP Server IP address | TFTP Server Name]
Load and execute system image from ROM or from TFTP server
C [address] Continue execution [optional address]
D /S M L V Deposit value V of size S into location L with modifier M
E /S M L Examine location L with size S with modifier M
G [address] Begin execution
H Help for commands
I Initialize
K Stack trace
L [filename] [TFTP Server IP address | TFTP Server Name]
Load system image from ROM or from TFTP server, but do not
begin execution
O Show configuration register option settings
P Set the break point
S Single step next instruction
T function Test device (? for help)
Deposit and Examine sizes may be B (byte), L (long) or S (short).
Modifiers may be R (register) or S (byte swap).
Register names are: D0-D7, A0-A6, SS, US, SR, and PC
To return to user EXEC mode, enter c to continue. To boot the system image file, use the b command (described in the "System Image and Configuration File Load Commands" chapter in the Access and Communication Servers Command Reference publication).
|
|