cc/td/doc/product/lan/cat5000/rel_4_1
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

Specifications

Specifications

This appendix lists the specifications for the Catalyst 5000 series switching modules, and is divided into the following sections:


Note For specifications on Catalyst 5000 series switch chassis, refer to the Catalyst 5000 Series Installation Guide.

Module Specifications

This section provides specifications for the switching modules and the Route Switch Module (RSM) used in Catalyst 5000 series switches.

Standards Compliance

Catalyst 5000 series modules, when installed in a system, comply with the standards listed in Table A-1:


Note The ATM dual PHY DS3 module (WS-X5166) complies with FCC Class A only.


Table A-1: Standards Compliance
Specification Description
Compliance: CE Marking
Safety

UL1 1950, CSA2-C22.2 No. 950, EN3 60950, IEC4 950, TS5 001, AS/NZS6 3260

EMI7

FCC8 Class A (47 CFR, Part 15), EN 55022 Class A and VCCI,9 Class A, AS/NZS 3548 Class A with UTP10 cables, EN 55022, Class B and VCCI Class B, AS/NZS 3590, Class B with STP11 cables

Network homologation12

Net 1, Net 2, Net 3, Net 513


1 UL = Underwriters Laboratories
2 CSA = Canadian Standards Association
3 EN = Europäische Norm
4 IEC = International Electrotechnical Commission
5 TS = Technical Standard
6 AS/NZS = Australian/New Zealand Standard
7 EMI = electromagnetic interference
8 FCC = Federal Communications Commission
9 VCCI = Voluntary Control Council for Information Technology Equipment
10 UTP = unshielded twisted-pair
11 STP = shielded twisted-pair
12 Applies to the Route Switch Module
13 For more information on network homologation standards, see the Regulatory Compliance and Safety Information for Cisco 7000 Series Routers, Regulatory Compliance and Safety Information for Cisco 7200 Series Routers, and Regulatory Compliance and Safety Information for Cisco 7500 Series Routers publications

The ATM dual PHY DS3 module (WS-X5166) also meets Japan Approvals Institute for Telecommunications Equipment (JATE) approval:

Applicant name: Nihon Cisco Systems
Model number: WS-X5166
Approval number: N98-N316-0
Date of approval: March 18, 1998

Group Switching Ethernet and Fast Ethernet Modules

Table A-2 describes the specifications of the following modules:


Table A-2: Group Switching Ethernet, Group Switching Fast Ethernet, and Workgroup Fast Ethernet Switching Module Specifications
Specification Description
Dimensions (H x W x D) 1.18 x 15.51 x 16.34 in. (30 x 394 x 415 mm)
Weight 5.7 lb (2.53 kg)
Environmental Conditions:
Operating temperature

32 to 104°F (0 to 40°C)

Nonoperating temperature

-40 to 167°F (-40 to 75°C)

Humidity

10 to 90%, noncondensing

Connectors 10BaseT (WS-X5020): RJ-21, female, telco
100BaseTX (WS-X5223 and WS-X5224): RJ-45
RAM buffer memory 192 KB per group
Maximum station-to-station cabling distance 10BaseT Ethernet: Categories 3-5 UTP: 328 ft (100 m)
100-ohm STP: 328 ft (100 m)
Frame Processing Transparent Bridging (IEEE 802.1d)
Network Management Cisco Discovery Protocol, Ethernet MIB (RFC 1398), Interface Table (RFC 1573), Bridge MIB (RFC 1493), Ethernet Repeater MIB (RFC 1516), RMON MIB (RFC 1757), Cisco Workgroup MIB, and Cisco VLAN Trunk Protocol

Ethernet and Fast Ethernet Switching Modules

Table A-3 describes the specifications for the following modules:


Table A-3: Ethernet and Fast Ethernet Switching Module
Specifications
Specification Description
Dimensions (H x W x D)

1.18 x 15.51 x 16.34 in. (30 x 394 x 415 mm)

Weight

Minimum: 3 lb (1.36 kg)
Maximum: 5 lb (2.27 kg)

Environmental Conditions:

Operating temperature

32 to 104°F (0 to 40°C)

Nonoperating temperature

-40 to 167°F (-40 to 75°C)

Humidity

10 to 90%, noncondensing

Connectors

10BaseT: RJ-21 (telco) and RJ-45
10BaseFL: ST
10/100BaseTX and 100BaseTX: RJ-45
Multimode fiber-optic, 100BaseFX: SC
Single-mode fiber-optic, 100BaseFX: SC

RAM buffer memory

192 KB per interface
10BaseT 48 port (WS-X5012): 348 KB per group of 24 ports

Maximum station-to-station cabling distance

10BaseT Ethernet, Categories 3-5 UTP: 328 ft (100 m); 100-ohm STP: 328 ft (100 m)

10BaseFL Ethernet, 62.5/125-micron multimode fiber: 1.2 miles (2 km) half or full duplex

10/100BaseTX and 100BaseTX Ethernet, Category 5 UTP: 328 ft (100 m); 100-ohm STP: 328 ft (100 m) half or full duplex

100BaseFX Fast Ethernet, 62.5/125-micron multimode fiber: 1312 ft (400 m) half duplex, 1.2 miles (2 km) half or full duplex

100BaseFX Fast Ethernet, 8/125-micron single-mode fiber: 16.1 miles (10 km) half or full duplex

Frame Processing

Transparent Bridging (802.1d)

Network Management

Cisco Discovery Protocol, Interface Table (RFC 1573), Bridge MIB (RFC 1493), Cisco Workgroup MIB, and Cisco VLAN Trunk Protocol

Gigabit Ethernet Switching Module

Table A-4 describes the specifications for the Gigabit Ethernet switching module (3 port) (WS-X5403).


Table A-4: Gigabit Ethernet Switching Module Specifications
Specifications Description
Dimensions (H x W x D) 1.18 x 15.51 x 16.34 in. (30 x 394 x 415 mm)
Weight Minimum: 3 lb (1.36 kg)
Maximum: 5 lb (2.27 kg)
Environmental Conditions:
Operating temperature

32 to 104°F (0 to 40°C)

Nonoperating temperature

-40 to 167°F (-40 to 75°C)

Humidity

10 to 90%, noncondensing

Connectors Single-mode fiber-optic: SC
RAM buffer memory 18 MB (6 MB per port)
Maximum station-to-station cabling distance Long-wavelength (1300 nm) laser device over MMF/SMF1

  • 62.5 micron MMF: 1444 feet (440 m)

  • 50 micron MMF: 1805 feet (550 m)

  • 10 micron SMF: 9843 feet (3000 m)

Short-wavelength (850 nm) laser device over MMF

  • 62.5 micron MMF: 853 feet (260 m)

  • 50 micron MMF: 1805 feet (550 m)

Frame Processing

Transparent Bridging (802.1d)
Network Management Cisco Discovery Protocol, Interface Table (RFC 1573), Bridge MIB (RFC 1493), Cisco Workgroup MIB, and Cisco VLAN Trunk Protocol

1 MMF/SMF=Multimode Fiber/Single-Mode Fiber

CDDI and FDDI Modules

Table A-5 describes the specifications for the following modules:


Table A-5: CDDI and FDDI Modules Specifications
Specification Description
Dimensions (H x W x D) 1.18 x 15.51 x 16.34 in. (30 x 394 x 415 mm)
Weight Minimum: 3 lb (1.36 kg)
Maximum: 5 lb (2.27 kg)
Environmental Conditions:
Operating temperature

32 to 104°F (0 to 40°C)

Nonoperating temperature

-40 to 167°F (-40 to 75°C)

Humidity

10 to 90%, noncondensing

Connectors Multimode fiber-optic: MIC1
Single-mode fiber-optic: ST2
Category 5 UTP3: RJ-45
RAM buffer memory 192 KB per interface
Maximum station-to-station cabling distance Category 5 UTP: 328 ft (100 m)
Multimode fiber, 62.5/125-micron: 1.2 miles (2 km)
Single-mode fiber: 18 miles (30 km)
Frame Processing Fragmentation (RFC 791), Translation (802.1h, 802.li), APaRT4
Network Management Cisco Discovery Protocol, SNMP5 MIB II (RFC 1213), FDDI6 MIB 7(RFC 1512), Interface Extensions MIB (RFC 1573), 802.1D Spanning-Tree MIB, Bridging MIB (RFC 1493), FDDI SMT8 7.3, Cisco Workgroup MIB, CiscoView application

1 MIC=media interface connector
2 ST=straight through
3 UTP=unshielded twisted-pair
4 APaRT=automated packet recognition/translation
5 SNMP=Simple Network Management Protocol
6 FDDI=Fiber Distributed Data Interface
7 MIB=management information base
8 SMT=station management

ATM LAN Emulation Modules

Table A-6 describes the specifications for the following ATM LAN Emulation (LANE) modules:



Table A-6: ATM LANE Module Specifications
Specification Description
Dimensions (H x W x D)

1.18 x 15.51 x 16.34 in. (30 x 394 x 415 mm)

Weight

Minimum: 3 lb (1.36 kg)

Maximum: 5 lb (2.27 kg)
Environmental Conditions:

Operating temperature

32 to 104°F (0 to 40°C)

Nonoperating temperature

-40 to 167°F (-40 to 75°C)

Humidity

10 to 90%, noncondensing

Connectors

Multimode fiber-optic: SC

Single-mode fiber-optic: SC
Category 5 UTP: RJ-45
Memory:

RAM buffer

192 KB per interface

Flash

4 MB

DRAM1

16 MB

EPROM2

512 KB

NVRAM3

128 KB

Maximum station-to-station cabling distance

Multimode fiber: 1.2 miles (2 km)

Single-mode fiber: 6.2 miles (10 km)
Category 5 UTP: 328 ft (100 m)
Frame-to-cell conversion

AAL45, 4096 virtual circuits, 255 concurrent reassembly

Indicators:

Module status

Green (operational)

Port active status

Green (operational)

RX

Green flashing (receive activity)

TX

Green flashing (transmit activity)

ATM standards

RFC 1483 LLC5 SNAP6 Bridging Encapsulation (PVC7); ATM Forum LANE8 v1.0 LEC9, LECS10, LES11, BUS;12 UNI13 3.0/3.1, Q.2931 signaling protocols; ILMI14

Network management

Cisco Discovery Protocol; SNMP MIB II (RFC 1213); AToM MIB (RFC 1695); LEC MIB (ATM Forum LANE v1.0); Cisco Workgroup Stack MIB; Cisco VLAN Trunk Protocol MIB; Cisco LECS; LES/BUS MIB; ILMI MIB


1 DRAM=dynamic random-access memory
2 EPROM= erasable programmable read-only memory
3 NVRAM=nonvolatile random-access memory
4 AAL=ATM adaptation layer
5 LLC=Logical Link Control
6 SNAP=Subnetwork Access Protocol
7 PVC=permanent virtual circuit
8 LANE=LAN Emulation
9 LEC=LAN Emulation Client
10 LECS=LAN Emulation Configuration Server
11 LES=LAN Emulation Server
12 BUS=broadcast and unknown server
13 UNI=User-Network Interface
14 ILMI=Interim Local Management Interface

ATM Dual PHY OC-3 and OC-12 Modules

Table A-7 describes the specifications for the following ATM Dual PHY OC-3 and OC-12 modules:


Table A-7: ATM Dual PHY OC-3 and OC-12 Module Specifications
Specification Description
Dimensions (H x W x D) 1.18 x 15.51 x 16.34 in. (30 x 394 x 415 mm)

Weight

Minimum: 3 lb (1.36 kg)
Maximum: 5 lb (2.27 kg)
Environmental Conditions:
Operating temperature

32 to 104°F (0 to 40°C)

Nonoperating temperature

-40 to 167°F (-40 to 75°C)

Humidity

10 to 90%, noncondensing

Connectors Multimode fiber-optic: SC
Single-mode fiber-optic: SC
Memory:
RAM buffer

512 KB

Flash

4 or 8 MB

DRAM1

16 or 32 MB

EPROM2

512 KB

NVRAM3

512 KB

Maximum station-to-station cabling distance Multimode fiber: 1.2 miles (2 km)
Single-mode fiber: 6.2 miles (10 km)
Frame-to-cell conversion AAL45, 4096 virtual circuits, 255 concurrent reassembly
Indicators:
Module status

The switch performs a series of self-tests and diagnostic tests.
If all the tests pass, the LED is green.

TX (Transmit)

When a port is transmitting a packet, the LED is green; otherwise it is off.

RX (Receive)

When a port is receiving a packet, the LED is green; otherwise it is off.

Link

Displays the Link integrity status of an ATM port. If the integrity is good, the LED is green. If the link integrity is bad, the LED is off.

Active

When green, the port is active. If the LED is off, the port is the standby port.

Signal

When green, the LED indicates that a signal is being received on the optical port.

Network management Cisco Discovery Protocol; SNMP5 MIB6 II (RFC 1213); AToM MIB (RFC 1695); LEC7 MIB (ATM Forum LANE8 v1.0); Cisco Workgroup Stack MIB; VTP9 MIB; Cisco LECS10; LES11/BUS12 MIB; ILMI13 MIB
ATM standards RFC 1483 LLC14 SNAP15 Bridging Encapsulation (PVC16); ATM Forum LANE v1.0 LEC, LECS, LES, BUS; UNI17 3.0/3.1, Q.2931 signaling protocols; ILMI

1 DRAM=dynamic random-access memory
2 EPROM= erasable programmable read-only memory
3 NVRAM=nonvolatile random-access memory
4 AAL=ATM adaptation layer
5 SNMP=Simple Network Management Protocol
6 MIB=Management Information Base
7 LEC=LAN Emulation Client
8 LANE=LAN Emulation
9 VTP=VLAN Trunk Protocol
10 LECS=LAN Emulation Configuration Server
11 LES=LAN Emulation Server
12 BUS=broadcast and unknown server
13 ILMI=Interim Local Management Interface
14 LLC=Logical Link Control
15 SNAP=Subnetwork Access Protocol
16 PVC=permanent virtual circuit
17 UNI=User-Network Interface

ATM Dual PHY DS3 Module

Table A-8 lists the ATM Dual PHY DS3 Module (WS-X5166) specifications.


Table A-8: ATM Dual PHY DS3 Module Specifications
Specification Description
Dimensions (H x W x D)

1.18 x 15.51 x 16.34 in. (30 x 394 x 415 mm)

Weight

Minimum: 3 lb (1.36 kg)

Maximum: 5 lb (2.27 kg)
Environmental Conditions:

Operating temperature

32 to 104°F (0 to 40°C)

Nonoperating temperature

-40 to 167°F (-40 to 75°C)

Humidity

10 to 90%, noncondensing

Cable Coaxial (75-ohm RG-59)
Connectors

BNC (bayonet style, twist lock)

Memory:

RAM buffer

192 KB per interface

Flash

4 MB

DRAM1

16 MB

EPROM2

512 KB

NVRAM3

128 KB

Maximum station-to-station cabling distance Coaxial cable (DS3): 450 ft (137 m)
Frame-to-cell conversion

AAL5, 4096 virtual circuits, 255 concurrent reassembly

Data Rate 44,736 Mbps
Line Encoding B3ZS
Framing

C-bit parity, optionally PLCP4 with M23, otherwise ADM (ATM Framing)

Timing

Primary and secondary 8-kHz reference from internal (default) or network

Loopbacks Transmit and receive
Impedance 75 ohms nominal
Indicators:

Module status

Green (operational)

Port active status

Green (operational)

RX

Green flashing (receive activity)

TX

Green flashing (transmit activity)

ATM standards

RFC 1483 LLC5 SNAP6 Bridging Encapsulation (PVC7); UNI 3.0/3.1, Q.2931 signaling protocols; ILMI8

Network management

Cisco Discovery Protocol; SNMP9 MIB10 II (RFC 1213); AToM MIB (RFC 1695); Cisco Workgroup Stack MIB; Cisco VTP11 MIB; ILMI MIB


1 DRAM=dynamic random-access memory
2 EPROM=erasable programmable read-only memory
3 NVRAM=nonvolatile RAM
4 PLCP = physical layer convergence procedure
5 LLC=Logical Link Control
6 SNAP=Subnet Access Protocol
7 PVC=permanent virtual circuit
8 ILMI=Interim Local Managment Interface
9 SNMP=Simple Network Management Protocol
10 MIB=Management Information Base
11 VTP=VLAN Trunk Protocol

Token Ring Module

Table A-9 lists the Token Ring module (WS-X5030) specifications.


Table A-9: Token Ring Module Specifications
Specification Description
Dimensions (H x W x D) 1.18 x 15.51 x 16.34 in. (30 x 394 x 415 mm)
Weight 3.9 lb (1.45 kg)
Environmental Conditions:
Operating temperature

32 to 104°F (0 to 40°C)

Nonoperating temperature

-40 to 167°F (-40 to 75°C)

Humidity

10 to 90%, noncondensing

Connectors 16 RJ-45 IEEE 802.5 Token Ring (UTP1/STP2) (Token Ring module)
16 Volition VF-45 MMF connectors (fiber Token Ring module)
Frame Processing Source-route, source-route transparent, source-route switching
Network Management SNMP3

1 UTP=unshielded twisted-pair
2 STP=shielded twisted-pair
3 SNMP = Simple Network Management Protocol

Route Switch Module

Table A-10 lists the Route Switch Module (WS-X5302) specifications.


Table  A-10: RSM Specifications
Description Specification
Processors 2 R4700 RISC1 processors running at external clock speeds of 50 MHz and internal clock speeds of 100 MHz
Memory:
DRAM2

32-MB (minimum), 64-MB, or 128-MB main and shared memory; available in 8-MB (8 x 4), 16-MB (16 x 4), or 32-MB (32 x 4) SIMMs3

NVRAM4

128-KB nonvolatile EPROM5 for the system configuration file

Flash SIMM

8-MB or 16-MB onboard Flash SIMMs for the Cisco IOS images

Flash Card

8-MB, 16-MB, or 20-MB PCMCIA6 card for the Cisco IOS images; the RSM has two PCMCIA slots providing a maximum of 40-MB Flash card memory

Boot ROM

256-KB EPROM for the ROM monitor program

Interfaces

1 serial console port
1 serial auxiliary port
Backplane interface: 2 SAGE ASICs7


1 RISC = Reduced Instruction Set Computing
2 DRAM = dynamic random-access memory
3 SIMMs=single in-line memory modules
4 NVRAM=nonvolatile RAM
5 EPROM=erasable programmable read-only memory
6 PCMCIA=Personal Computer Memory Card International Association
7 ASICs=application-specific integrated circuits

Optical Specifications

Table A-11 lists the optical specifications for the Catalyst 5000 series switching modules.


Table A-11: Optical Specifications
Specification Multimode1 Single-Mode2 Single-Mode3
Transmitter output power -19 to -14 dBm4 -14 to -8 dBm -4.0 to -7.0 dBm
Receiver sensitivity -32.5 to -14 dBm 32.5 to -8 dBm N/A
Wavelength 850 to 1360 nm 1261 to 1360 nm 1261 to 1360 nm
Optical source LED Laser Laser
Maximum span 1.2 miles (2 km) 6.2 miles (10 km) 18 miles (30 km)

1 Applies to modules WS-X5005, WS-X5011, WS-X5155, WS-X5114, WS-X5101, WS-X5201, WS-X5158, WS-X5162, and WS-X5167
2 Applies to modules WS-X5006, WS-X5157, WS-X5114, WS-X5154, WS-X5161, and WS-X5168
3 Applies to module WS-X5104
4 dBm = decibels per milliwatt

Connector Output Signal and Cable Pinout Specifications

This section lists and defines the output signals for ports on the supervisor engine module, switching modules, and the RSM. It also defines the cable pinouts for certain interface cable connectors that connect modules to the external network. All pins not specifically listed are not connected.

The following is a list of the signal summaries contained in this appendix:

Fast Ethernet MII Connector Output Signals

Most Ethernet transceivers require a transceiver cable to connect an Ethernet transceiver to the supervisor engine module and Ethernet switching module Ethernet ports. Some unshielded twisted-pair (10BaseT) transceivers are compact enough to connect directly to the Ethernet module ports without impeding other connections. For descriptions of Ethernet transceivers, connectors, and cables, refer to Chapter 2, "Installation Preparation."

Table A-12 lists the output signals for the 40-pin media-independent interface (MII) Fast Ethernet connector on the supervisor engine module.

Caution  Table A-12 lists the output signals from the MII connector on the supervisor engine module, not the pinouts of the cable connecting to the module.


Table A-12: Supervisor Engine Module 40-Pin MII Fast Ethernet Connector Output Signals
Pin Signal
1 +5V
2 MDIO
3 MDC
4 RxD<3>
5 RxD<2>
6 RxD<1>
7 RxD<0>
8 Rx_DV
9 Rx_Clk
10 Rx_Er
11 Tx_Er
12 Tx_Clk
13 Tx_En
14 TxD<0>
15 TxD<1>
16 TxD<2>
17 TxD<3>
18 Col
19 CRS
20 +5V
21 +5V
22 Common
23 Common
24 Common
25 Common
26 Common
27 Common
28 Common
29 Common
30 Common
31 Common
32 Common
33 Common
34 Common
35 Common
36 Common
37 Common
38 Common
39 Common
40 +5V

Fast Ethernet TX MDI X Port Output Signals

Table A-13 lists the output signals for the RJ-45 Fast Ethernet 100BaseTX MDI X connector and Fast Ethernet 100BaseTX module connectors on the supervisor engine module.

Caution  
Caution Table A-13 lists the output signals for the RJ-45 Fast Ethernet 100BaseTX MDI X connector and Fast Ethernet 100BaseTX module connectors on the supervisor engine module, not the pinouts of the cable connecting to the modules.


Table A-13: Fast Ethernet 100BaseTX MDI X Port Output Signals
Pin Signal Direction Description
1 RxD+ <-- Receive Data +
2 RxD- <-- Receive Data -
3 TxD+ --> Transmit Data +
4 NC No Connection
5 NC No Connection
6 TxD- --> Transmit Data -
7 NC No Connection
8 NC No Connection

Ethernet 10BaseT RJ-21 Telco Connector Output Signals

Table A-14 lists the output signals for the RJ-21 telco connector on the Ethernet switching module (10BaseT 24 port) and the Ethernet switching module (10BaseT 48 port).

Caution  Table A-14 lists the output signals for the RJ-21 telco connector, not the pinouts of the cable connecting to the module.


Table A-14: Ethernet 10BaseT RJ-21 Telco Connector Output
Signals

Pin

Signal

Direction

Description
Ethernet
Port No.
1 RxD (+ or -) <-- Receive Data 1
2 TxD (+ or -) --> Transmit Data 1
26 RxD (+ or -) <-- Receive Data 1
27 TxD (+ or -) --> Transmit Data 1
3 RxD (+ or -) <-- Receive Data 2
4 TxD (+ or -) --> Transmit Data 2
28 RxD (+ or -) <-- Receive Data 2
29 TxD (+ or -) --> Transmit Data 2
5 RxD (+ or -) <-- Receive Data 3
6 TxD (+ or -) --> Transmit Data 3
30 RxD (+ or -) <-- Receive Data 3
31 TxD (+ or -) --> Transmit Data 3
7 RxD (+ or -) <-- Receive Data 4
8 TxD (+ or -) --> Transmit Data 4
32 RxD (+ or -) <-- Receive Data 4
33 TxD (+ or -) --> Transmit Data 4
9 RxD (+ or -) <-- Receive Data 5
10 TxD (+ or -) --> Transmit Data 5
34 RxD (+ or -) <-- Receive Data 5
35 TxD (+ or -) --> Transmit Data 5
11 RxD (+ or -) <-- Receive Data 6
12 TxD (+ or -) --> Transmit Data 6
36 RxD (+ or -) <-- Receive Data 6
37 TxD (+ or -) --> Transmit Data 6
13 RxD (+ or -) <-- Receive Data 7
14 TxD (+ or -) --> Transmit Data 7
38 RxD (+ or -) <-- Receive Data 7
39 TxD (+ or -) --> Transmit Data 7
15 RxD (+ or -) <-- Receive Data 8
16 TxD (+ or -) --> Transmit Data 8
40 RxD (+ or -) <-- Receive Data 8
41 TxD (+ or -) --> Transmit Data 8
17 RxD (+ or -) <-- Receive Data 9
18 TxD (+ or -) --> Transmit Data 9
42 RxD (+ or -) <-- Receive Data 9
43 TxD (+ or -) --> Transmit Data 9
19 RxD (+ or -) <-- Receive Data 10
20 TxD (+ or -) --> Transmit Data 10
44 RxD (+ or -) <-- Receive Data 10
45 TxD (+ or -) --> Transmit Data 10
21 RxD (+ or -) <-- Receive Data 11
22 TxD (+ or -) --> Transmit Data 11
46 RxD (+ or -) <-- Receive Data 11
47 TxD (+ or -) --> Transmit Data 11
23 RxD (+ or -) <-- Receive Data 12
24 TxD (+ or -) --> Transmit Data 12
48 RxD (+ or -) <-- Receive Data 12
49 TxD (+ or -) --> Transmit Data 12
25 (Not Used)
50 (Not Used)

ATM LANE Module (UTP) Connector Output Signals

Table A-15 lists the output signals for the RJ-45 connector on the ATM LANE module (UTP).

Caution  Table A-15 lists the output signals for the RJ-45 connector on the ATM LANE module (UTP), not the pinouts of the cable connecting to the module.

Table A-15: ATM LANE Module (UTP) RJ-45 Connector Output Signals
Pin Signal Direction Description
1 TxD+ --> Transmit Data +
2 TxD- --> Transmit Data -
3 NC No Connection
4 NC No Connection
5 NC No Connection
6 NC No Connection
7 RxD+ <-- Receive Data +
8 RxD- <-- Receive Data -

FDDI Optical Bypass Connector Output Signals

Table A-16 lists the output signal descriptions for the mini-DIN connector on the optical bypass switch that is available on FDDI modules. A mini-DIN-to-DIN adapter cable connector allows connection to an optical bypass switch that uses a DIN connector.

Caution  Table A-16 lists the output signals for the mini-DIN connector on the optical bypass switch, not the pinouts of the cable connecting to the optical bypass switch.

Table A-16: Optical Bypass Switch Mini-DIN Connector Output Signals
Pin Description
1 +5V to secondary switch
2 +5V to primary switch
3 Ground to enable primary switch
4 Ground to enable secondary switch
5 Sense circuit--1 kohm to +5V
6 Ground--Sense circuit return

CDDI Transmit and Receive Connector Pinouts

Table A-17 lists the pinouts of straight-through cable connectors used with CDDI modules.

Caution  Table A-17 lists the pinouts for the straight-through cable connectors used with CDDI modules, not the output signals of the connector on the CDDI modules.

Table A-17: CDDI Straight-Through Connector Pinouts
Pin Signal Direction Signal Pin
1 TxD --> RxD 1
2 TxD --> RxD 2
3 NC No Connection NC 3
4 NC No Connection NC 4
5 NC No Connection NC 5
6 NC No Connection NC 6
7 RxD <-- TxD 7
8 RxD <-- TxD 8

Table A-18 lists the pinouts for cross-connect connectors used with CDDI modules.

Caution  Table A-18 lists the pinouts for the cross-connect cable connectors used with CDDI modules, not the output signals of the connector on the CDDI modules.

Table A-18: CDDI Cross-Connect Connector Pinouts
Pin Signal Direction Signal Pin
1 RxD <-- TxD 8
2 RxD <-- TxD 7
3 NC No Connection NC 6
4 NC No Connection NC 5
5 NC No Connection NC 4
6 NC No Connection NC 3
7 TxD --> RxD 2
8 TxD --> RxD 1

RSM Console and Auxiliary Port Pinouts

For information on the RSM console and auxiliary port pinouts, refer to the Catalyst 5000 Series Route Switch Module Installation and Configuration Note.


hometocprevnextglossaryfeedbacksearchhelp
Copyright 1989-1998 © Cisco Systems Inc.