This appendix lists the specifications for the Catalyst 5000 series switching modules, and is divided into the following sections:
This section provides specifications for the switching modules and the Route Switch Module (RSM) used in Catalyst 5000 series switches.
Catalyst 5000 series modules, when installed in a system, comply with the standards listed in Table A-1:
| Specification | Description |
|---|---|
| Compliance: | CE Marking |
|
UL1 1950, CSA2-C22.2 No. 950, EN3 60950, IEC4 950, TS5 001, AS/NZS6 3260 |
|
FCC8 Class A (47 CFR, Part 15), EN 55022 Class A and VCCI,9 Class A, AS/NZS 3548 Class A with UTP10 cables, EN 55022, Class B and VCCI Class B, AS/NZS 3590, Class B with STP11 cables |
|
Net 1, Net 2, Net 3, Net 513 |
The ATM dual PHY DS3 module (WS-X5166) also meets Japan Approvals Institute for Telecommunications Equipment (JATE) approval:
| Applicant name: | Nihon Cisco Systems |
| Model number: | WS-X5166 |
| Approval number: | N98-N316-0 |
| Date of approval: | March 18, 1998 |
Table A-2 describes the specifications of the following modules:
| Specification | Description |
|---|---|
| Dimensions (H x W x D) | 1.18 x 15.51 x 16.34 in. (30 x 394 x 415 mm) |
| Weight | 5.7 lb (2.53 kg) |
| Environmental Conditions: | |
|
32 to 104°F (0 to 40°C) |
|
-40 to 167°F (-40 to 75°C) |
|
10 to 90%, noncondensing |
| Connectors | 10BaseT (WS-X5020): RJ-21, female, telco 100BaseTX (WS-X5223 and WS-X5224): RJ-45 |
| RAM buffer memory | 192 KB per group |
| Maximum station-to-station cabling distance | 10BaseT Ethernet: Categories 3-5 UTP: 328 ft (100 m) 100-ohm STP: 328 ft (100 m) |
| Frame Processing | Transparent Bridging (IEEE 802.1d) |
| Network Management | Cisco Discovery Protocol, Ethernet MIB (RFC 1398), Interface Table (RFC 1573), Bridge MIB (RFC 1493), Ethernet Repeater MIB (RFC 1516), RMON MIB (RFC 1757), Cisco Workgroup MIB, and Cisco VLAN Trunk Protocol |
Table A-3 describes the specifications for the following modules:
| Specification | Description | ||
|---|---|---|---|
| Dimensions (H x W x D) | 1.18 x 15.51 x 16.34 in. (30 x 394 x 415 mm) | ||
| Weight | Minimum: 3 lb (1.36 kg) | ||
| Environmental Conditions: |
| ||
|
32 to 104°F (0 to 40°C) | ||
|
-40 to 167°F (-40 to 75°C) | ||
|
10 to 90%, noncondensing | ||
| Connectors | 10BaseT: RJ-21 (telco) and RJ-45 | ||
| RAM buffer memory | 192 KB per interface | ||
Maximum station-to-station cabling distance | 10BaseT Ethernet, Categories 3-5 UTP: 328 ft (100 m); 100-ohm STP: 328 ft (100 m) | ||
10BaseFL Ethernet, 62.5/125-micron multimode fiber: 1.2 miles (2 km) half or full duplex | |||
10/100BaseTX and 100BaseTX Ethernet, Category 5 UTP: 328 ft (100 m); 100-ohm STP: 328 ft (100 m) half or full duplex | |||
100BaseFX Fast Ethernet, 62.5/125-micron multimode fiber: 1312 ft (400 m) half duplex, 1.2 miles (2 km) half or full duplex | |||
100BaseFX Fast Ethernet, 8/125-micron single-mode fiber: 16.1 miles (10 km) half or full duplex | |||
| Frame Processing | Transparent Bridging (802.1d) | ||
| Network Management | Cisco Discovery Protocol, Interface Table (RFC 1573), Bridge MIB (RFC 1493), Cisco Workgroup MIB, and Cisco VLAN Trunk Protocol | ||
Table A-4 describes the specifications for the Gigabit Ethernet switching module (3 port) (WS-X5403).
| Specifications | Description |
|---|---|
| Dimensions (H x W x D) | 1.18 x 15.51 x 16.34 in. (30 x 394 x 415 mm) |
| Weight | Minimum: 3 lb (1.36 kg) Maximum: 5 lb (2.27 kg) |
| Environmental Conditions: | |
|
32 to 104°F (0 to 40°C) |
|
-40 to 167°F (-40 to 75°C) |
|
10 to 90%, noncondensing |
| Connectors | Single-mode fiber-optic: SC |
| RAM buffer memory | 18 MB (6 MB per port) |
| Maximum station-to-station cabling distance | Long-wavelength (1300 nm) laser device over MMF/SMF1
Short-wavelength (850 nm) laser device over MMF
|
|
Frame Processing | Transparent Bridging (802.1d) |
| Network Management | Cisco Discovery Protocol, Interface Table (RFC 1573), Bridge MIB (RFC 1493), Cisco Workgroup MIB, and Cisco VLAN Trunk Protocol |
Table A-5 describes the specifications for the following modules:
| Specification | Description |
|---|---|
| Dimensions (H x W x D) | 1.18 x 15.51 x 16.34 in. (30 x 394 x 415 mm) |
| Weight | Minimum: 3 lb (1.36 kg) Maximum: 5 lb (2.27 kg) |
| Environmental Conditions: | |
|
32 to 104°F (0 to 40°C) |
|
-40 to 167°F (-40 to 75°C) |
|
10 to 90%, noncondensing |
| Connectors | Multimode fiber-optic: MIC1 Single-mode fiber-optic: ST2 Category 5 UTP3: RJ-45 |
| RAM buffer memory | 192 KB per interface |
| Maximum station-to-station cabling distance | Category 5 UTP: 328 ft (100 m) Multimode fiber, 62.5/125-micron: 1.2 miles (2 km) Single-mode fiber: 18 miles (30 km) |
| Frame Processing | Fragmentation (RFC 791), Translation (802.1h, 802.li), APaRT4 |
| Network Management | Cisco Discovery Protocol, SNMP5 MIB II (RFC 1213), FDDI6 MIB 7(RFC 1512), Interface Extensions MIB (RFC 1573), 802.1D Spanning-Tree MIB, Bridging MIB (RFC 1493), FDDI SMT8 7.3, Cisco Workgroup MIB, CiscoView application |
Table A-6 describes the specifications for the following ATM LAN Emulation (LANE) modules:
| Specification | Description | |
|---|---|---|
| Dimensions (H x W x D) | 1.18 x 15.51 x 16.34 in. (30 x 394 x 415 mm) | |
Weight | Minimum: 3 lb (1.36 kg) | |
| Maximum: 5 lb (2.27 kg) | ||
| Environmental Conditions: |
| |
|
32 to 104°F (0 to 40°C) | |
|
-40 to 167°F (-40 to 75°C) | |
|
10 to 90%, noncondensing | |
| Connectors | Multimode fiber-optic: SC | |
| Single-mode fiber-optic: SC | ||
| Category 5 UTP: RJ-45 | ||
| Memory: |
| |
|
192 KB per interface | |
|
4 MB | |
|
16 MB | |
|
512 KB | |
|
128 KB | |
Maximum station-to-station cabling distance | Multimode fiber: 1.2 miles (2 km) | |
| Single-mode fiber: 6.2 miles (10 km) | ||
| Category 5 UTP: 328 ft (100 m) | ||
| Frame-to-cell conversion | AAL45, 4096 virtual circuits, 255 concurrent reassembly | |
| Indicators: |
| |
|
Green (operational) | |
|
Green (operational) | |
|
Green flashing (receive activity) | |
|
Green flashing (transmit activity) | |
| ATM standards | RFC 1483 LLC5 SNAP6 Bridging Encapsulation (PVC7); ATM Forum LANE8 v1.0 LEC9, LECS10, LES11, BUS;12 UNI13 3.0/3.1, Q.2931 signaling protocols; ILMI14 | |
| Network management | Cisco Discovery Protocol; SNMP MIB II (RFC 1213); AToM MIB (RFC 1695); LEC MIB (ATM Forum LANE v1.0); Cisco Workgroup Stack MIB; Cisco VLAN Trunk Protocol MIB; Cisco LECS; LES/BUS MIB; ILMI MIB | |
Table A-7 describes the specifications for the following ATM Dual PHY OC-3 and OC-12 modules:
| Specification | Description |
|---|---|
| Dimensions (H x W x D) | 1.18 x 15.51 x 16.34 in. (30 x 394 x 415 mm) |
Weight | Minimum: 3 lb (1.36 kg) |
| Maximum: 5 lb (2.27 kg) | |
| Environmental Conditions: | |
|
32 to 104°F (0 to 40°C) |
|
-40 to 167°F (-40 to 75°C) |
|
10 to 90%, noncondensing |
| Connectors | Multimode fiber-optic: SC |
| Single-mode fiber-optic: SC | |
| Memory: | |
|
512 KB |
|
4 or 8 MB |
|
16 or 32 MB |
|
512 KB |
|
512 KB |
| Maximum station-to-station cabling distance | Multimode fiber: 1.2 miles (2 km) Single-mode fiber: 6.2 miles (10 km) |
| Frame-to-cell conversion | AAL45, 4096 virtual circuits, 255 concurrent reassembly |
| Indicators: | |
|
The switch performs a series of self-tests and diagnostic tests. |
|
When a port is transmitting a packet, the LED is green; otherwise it is off. |
|
When a port is receiving a packet, the LED is green; otherwise it is off. |
|
Displays the Link integrity status of an ATM port. If the integrity is good, the LED is green. If the link integrity is bad, the LED is off. |
|
When green, the port is active. If the LED is off, the port is the standby port. |
|
When green, the LED indicates that a signal is being received on the optical port. |
| Network management | Cisco Discovery Protocol; SNMP5 MIB6 II (RFC 1213); AToM MIB (RFC 1695); LEC7 MIB (ATM Forum LANE8 v1.0); Cisco Workgroup Stack MIB; VTP9 MIB; Cisco LECS10; LES11/BUS12 MIB; ILMI13 MIB |
| ATM standards | RFC 1483 LLC14 SNAP15 Bridging Encapsulation (PVC16); ATM Forum LANE v1.0 LEC, LECS, LES, BUS; UNI17 3.0/3.1, Q.2931 signaling protocols; ILMI |
Table A-8 lists the ATM Dual PHY DS3 Module (WS-X5166) specifications.
| Specification | Description | |
|---|---|---|
| Dimensions (H x W x D) | 1.18 x 15.51 x 16.34 in. (30 x 394 x 415 mm) | |
Weight | Minimum: 3 lb (1.36 kg) | |
| Maximum: 5 lb (2.27 kg) | ||
| Environmental Conditions: |
| |
|
32 to 104°F (0 to 40°C) | |
|
-40 to 167°F (-40 to 75°C) | |
|
10 to 90%, noncondensing | |
| Cable | Coaxial (75-ohm RG-59) | |
| Connectors | BNC (bayonet style, twist lock) | |
| Memory: |
| |
|
192 KB per interface | |
|
4 MB | |
|
16 MB | |
|
512 KB | |
|
128 KB | |
| Maximum station-to-station cabling distance | Coaxial cable (DS3): 450 ft (137 m) | |
| Frame-to-cell conversion | AAL5, 4096 virtual circuits, 255 concurrent reassembly | |
| Data Rate | 44,736 Mbps | |
| Line Encoding | B3ZS | |
| Framing | C-bit parity, optionally PLCP4 with M23, otherwise ADM (ATM Framing) | |
| Timing | Primary and secondary 8-kHz reference from internal (default) or network | |
| Loopbacks | Transmit and receive | |
| Impedance | 75 ohms nominal | |
| Indicators: |
| |
|
Green (operational) | |
|
Green (operational) | |
|
Green flashing (receive activity) | |
|
Green flashing (transmit activity) | |
| ATM standards | RFC 1483 LLC5 SNAP6 Bridging Encapsulation (PVC7); UNI 3.0/3.1, Q.2931 signaling protocols; ILMI8 | |
| Network management | Cisco Discovery Protocol; SNMP9 MIB10 II (RFC 1213); AToM MIB (RFC 1695); Cisco Workgroup Stack MIB; Cisco VTP11 MIB; ILMI MIB | |
Table A-9 lists the Token Ring module (WS-X5030) specifications.
| Specification | Description |
|---|---|
| Dimensions (H x W x D) | 1.18 x 15.51 x 16.34 in. (30 x 394 x 415 mm) |
| Weight | 3.9 lb (1.45 kg) |
| Environmental Conditions: | |
|
32 to 104°F (0 to 40°C) |
|
-40 to 167°F (-40 to 75°C) |
|
10 to 90%, noncondensing |
| Connectors | 16 RJ-45 IEEE 802.5 Token Ring (UTP1/STP2) (Token Ring module) 16 Volition VF-45 MMF connectors (fiber Token Ring module) |
| Frame Processing | Source-route, source-route transparent, source-route switching |
| Network Management | SNMP3 |
Table A-10 lists the Route Switch Module (WS-X5302) specifications.
| Description | Specification |
|---|---|
| Processors | 2 R4700 RISC1 processors running at external clock speeds of 50 MHz and internal clock speeds of 100 MHz |
| Memory: | |
|
32-MB (minimum), 64-MB, or 128-MB main and shared memory; available in 8-MB (8 x 4), 16-MB (16 x 4), or 32-MB (32 x 4) SIMMs3 |
|
128-KB nonvolatile EPROM5 for the system configuration file |
|
8-MB or 16-MB onboard Flash SIMMs for the Cisco IOS images |
|
8-MB, 16-MB, or 20-MB PCMCIA6 card for the Cisco IOS images; the RSM has two PCMCIA slots providing a maximum of 40-MB Flash card memory |
|
256-KB EPROM for the ROM monitor program |
|
1 serial console port |
Table A-11 lists the optical specifications for the Catalyst 5000 series switching modules.
| Specification | Multimode1 | Single-Mode2 | Single-Mode3 |
|---|---|---|---|
| Transmitter output power | -19 to -14 dBm4 | -14 to -8 dBm | -4.0 to -7.0 dBm |
| Receiver sensitivity | -32.5 to -14 dBm | 32.5 to -8 dBm | N/A |
| Wavelength | 850 to 1360 nm | 1261 to 1360 nm | 1261 to 1360 nm |
| Optical source | LED | Laser | Laser |
| Maximum span | 1.2 miles (2 km) | 6.2 miles (10 km) | 18 miles (30 km) |
This section lists and defines the output signals for ports on the supervisor engine module, switching modules, and the RSM. It also defines the cable pinouts for certain interface cable connectors that connect modules to the external network. All pins not specifically listed are not connected.
The following is a list of the signal summaries contained in this appendix:
Most Ethernet transceivers require a transceiver cable to connect an Ethernet transceiver to the supervisor engine module and Ethernet switching module Ethernet ports. Some unshielded twisted-pair (10BaseT) transceivers are compact enough to connect directly to the Ethernet module ports without impeding other connections. For descriptions of Ethernet transceivers, connectors, and cables, refer to Chapter 2, "Installation Preparation."
Table A-12 lists the output signals for the 40-pin media-independent interface (MII) Fast Ethernet connector on the supervisor engine module.
Caution
| Table A-12 lists the output signals from the MII connector on the supervisor engine module, not the pinouts of the cable connecting to the module. |
| Pin | Signal | |
|---|---|---|
| 1 | +5V | |
| 2 | MDIO | |
| 3 | MDC | |
| 4 | RxD<3> | |
| 5 | RxD<2> | |
| 6 | RxD<1> | |
| 7 | RxD<0> | |
| 8 | Rx_DV | |
| 9 | Rx_Clk | |
| 10 | Rx_Er | |
| 11 | Tx_Er | |
| 12 | Tx_Clk | |
| 13 | Tx_En | |
| 14 | TxD<0> | |
| 15 | TxD<1> | |
| 16 | TxD<2> | |
| 17 | TxD<3> | |
| 18 | Col | |
| 19 | CRS | |
| 20 | +5V | |
| 21 | +5V | |
| 22 | Common | |
| 23 | Common | |
| 24 | Common | |
| 25 | Common | |
| 26 | Common | |
| 27 | Common | |
| 28 | Common | |
| 29 | Common | |
| 30 | Common | |
| 31 | Common | |
| 32 | Common | |
| 33 | Common | |
| 34 | Common | |
| 35 | Common | |
| 36 | Common | |
| 37 | Common | |
| 38 | Common | |
| 39 | Common | |
| 40 | +5V |
Table A-13 lists the output signals for the RJ-45 Fast Ethernet 100BaseTX MDI X connector and Fast Ethernet 100BaseTX module connectors on the supervisor engine module.
Caution
| Caution Table A-13 lists the output signals for the RJ-45 Fast Ethernet 100BaseTX MDI X connector and Fast Ethernet 100BaseTX module connectors on the supervisor engine module, not the pinouts of the cable connecting to the modules.
|
| Pin | Signal | Direction | Description |
|---|---|---|---|
| 1 | RxD+ | <-- | Receive Data + |
| 2 | RxD- | <-- | Receive Data - |
| 3 | TxD+ | --> | Transmit Data + |
| 4 | NC | No Connection | |
| 5 | NC | No Connection | |
| 6 | TxD- | --> | Transmit Data - |
| 7 | NC | No Connection | |
| 8 | NC | No Connection |
Table A-14 lists the output signals for the RJ-21 telco connector on the Ethernet switching module (10BaseT 24 port) and the Ethernet switching module (10BaseT 48 port).
Caution
| Table A-14 lists the output signals for the RJ-21 telco connector, not the pinouts of the cable connecting to the module. |
Pin | Signal | Direction | Description | Ethernet Port No. |
|---|---|---|---|---|
| 1 | RxD (+ or -) | <-- | Receive Data | 1 |
| 2 | TxD (+ or -) | --> | Transmit Data | 1 |
| 26 | RxD (+ or -) | <-- | Receive Data | 1 |
| 27 | TxD (+ or -) | --> | Transmit Data | 1 |
| 3 | RxD (+ or -) | <-- | Receive Data | 2 |
| 4 | TxD (+ or -) | --> | Transmit Data | 2 |
| 28 | RxD (+ or -) | <-- | Receive Data | 2 |
| 29 | TxD (+ or -) | --> | Transmit Data | 2 |
| 5 | RxD (+ or -) | <-- | Receive Data | 3 |
| 6 | TxD (+ or -) | --> | Transmit Data | 3 |
| 30 | RxD (+ or -) | <-- | Receive Data | 3 |
| 31 | TxD (+ or -) | --> | Transmit Data | 3 |
| 7 | RxD (+ or -) | <-- | Receive Data | 4 |
| 8 | TxD (+ or -) | --> | Transmit Data | 4 |
| 32 | RxD (+ or -) | <-- | Receive Data | 4 |
| 33 | TxD (+ or -) | --> | Transmit Data | 4 |
| 9 | RxD (+ or -) | <-- | Receive Data | 5 |
| 10 | TxD (+ or -) | --> | Transmit Data | 5 |
| 34 | RxD (+ or -) | <-- | Receive Data | 5 |
| 35 | TxD (+ or -) | --> | Transmit Data | 5 |
| 11 | RxD (+ or -) | <-- | Receive Data | 6 |
| 12 | TxD (+ or -) | --> | Transmit Data | 6 |
| 36 | RxD (+ or -) | <-- | Receive Data | 6 |
| 37 | TxD (+ or -) | --> | Transmit Data | 6 |
| 13 | RxD (+ or -) | <-- | Receive Data | 7 |
| 14 | TxD (+ or -) | --> | Transmit Data | 7 |
| 38 | RxD (+ or -) | <-- | Receive Data | 7 |
| 39 | TxD (+ or -) | --> | Transmit Data | 7 |
| 15 | RxD (+ or -) | <-- | Receive Data | 8 |
| 16 | TxD (+ or -) | --> | Transmit Data | 8 |
| 40 | RxD (+ or -) | <-- | Receive Data | 8 |
| 41 | TxD (+ or -) | --> | Transmit Data | 8 |
| 17 | RxD (+ or -) | <-- | Receive Data | 9 |
| 18 | TxD (+ or -) | --> | Transmit Data | 9 |
| 42 | RxD (+ or -) | <-- | Receive Data | 9 |
| 43 | TxD (+ or -) | --> | Transmit Data | 9 |
| 19 | RxD (+ or -) | <-- | Receive Data | 10 |
| 20 | TxD (+ or -) | --> | Transmit Data | 10 |
| 44 | RxD (+ or -) | <-- | Receive Data | 10 |
| 45 | TxD (+ or -) | --> | Transmit Data | 10 |
| 21 | RxD (+ or -) | <-- | Receive Data | 11 |
| 22 | TxD (+ or -) | --> | Transmit Data | 11 |
| 46 | RxD (+ or -) | <-- | Receive Data | 11 |
| 47 | TxD (+ or -) | --> | Transmit Data | 11 |
| 23 | RxD (+ or -) | <-- | Receive Data | 12 |
| 24 | TxD (+ or -) | --> | Transmit Data | 12 |
| 48 | RxD (+ or -) | <-- | Receive Data | 12 |
| 49 | TxD (+ or -) | --> | Transmit Data | 12 |
| 25 | (Not Used) | |||
| 50 | (Not Used) |
Table A-15 lists the output signals for the RJ-45 connector on the ATM LANE module (UTP).
Caution
| Table A-15 lists the output signals for the RJ-45 connector on the ATM LANE module (UTP), not the pinouts of the cable connecting to the module. |
| Pin | Signal | Direction | Description |
|---|---|---|---|
| 1 | TxD+ | --> | Transmit Data + |
| 2 | TxD- | --> | Transmit Data - |
| 3 | NC | No Connection | |
| 4 | NC | No Connection | |
| 5 | NC | No Connection | |
| 6 | NC | No Connection | |
| 7 | RxD+ | <-- | Receive Data + |
| 8 | RxD- | <-- | Receive Data - |
Table A-16 lists the output signal descriptions for the mini-DIN connector on the optical bypass switch that is available on FDDI modules. A mini-DIN-to-DIN adapter cable connector allows connection to an optical bypass switch that uses a DIN connector.
Caution
| Table A-16 lists the output signals for the mini-DIN connector on the optical bypass switch, not the pinouts of the cable connecting to the optical bypass switch. |
| Pin | Description |
|---|---|
| 1 | +5V to secondary switch |
| 2 | +5V to primary switch |
| 3 | Ground to enable primary switch |
| 4 | Ground to enable secondary switch |
| 5 | Sense circuit--1 kohm to +5V |
| 6 | Ground--Sense circuit return |
Table A-17 lists the pinouts of straight-through cable connectors used with CDDI modules.
Caution
| Table A-17 lists the pinouts for the straight-through cable connectors used with CDDI modules, not the output signals of the connector on the CDDI modules. |
| Pin | Signal | Direction | Signal | Pin |
|---|---|---|---|---|
| 1 | TxD | --> | RxD | 1 |
| 2 | TxD | --> | RxD | 2 |
| 3 | NC | No Connection | NC | 3 |
| 4 | NC | No Connection | NC | 4 |
| 5 | NC | No Connection | NC | 5 |
| 6 | NC | No Connection | NC | 6 |
| 7 | RxD | <-- | TxD | 7 |
| 8 | RxD | <-- | TxD | 8 |
Table A-18 lists the pinouts for cross-connect connectors used with CDDI modules.
Caution
| Table A-18 lists the pinouts for the cross-connect cable connectors used with CDDI modules, not the output signals of the connector on the CDDI modules. |
| Pin | Signal | Direction | Signal | Pin |
|---|---|---|---|---|
| 1 | RxD | <-- | TxD | 8 |
| 2 | RxD | <-- | TxD | 7 |
| 3 | NC | No Connection | NC | 6 |
| 4 | NC | No Connection | NC | 5 |
| 5 | NC | No Connection | NC | 4 |
| 6 | NC | No Connection | NC | 3 |
| 7 | TxD | --> | RxD | 2 |
| 8 | TxD | --> | RxD | 1 |
For information on the RSM console and auxiliary port pinouts, refer to the Catalyst 5000 Series Route Switch Module Installation and Configuration Note.
|
|