This appendix provides technical specifications for the Catalyst 5000 series switches:
Refer to the Catalyst 5000 Series Module Installation Guide for switching module and interface port specifications.
Catalyst 5002 specifications are provided in Table A-1.
| Item | Specification | |
|---|---|---|
| Environmental | ||
| Temperature, ambient operating | 32°F (0°C) to 104°F (40°C) | |
| Temperature, ambient nonoperating and storage | -40 to 158°F (-40 to 70°C) | |
| Humidity (RH), ambient (noncondensing) operating | 10% to 90% | |
| Humidity (RH), ambient (noncondensing) nonoperating and storage | 5% to 95% | |
| Altitude, operating and nonoperating | Sea level to 10,000 ft. (3050 m) | |
| Switching Components | ||
| Backplane | 1.2-Gbps | |
| Microprocessor | Supervisor Engine I and II: 25-MHz 68EC040 for the NMP1 Supervisor Engine III: 150-MHz IDT R4700 RISC | |
| Memory |
| |
| Supervisor Engine I
Supervisor Engine II Supervisor Engine III | DRAM2: 20 MB, Flash (onboard)-4 MB, NVRAM-256 KB DRAM: 16 MB, Flash (onboard)-4 MB, NVRAM-256 KB DRAM: 32 MB, Flash (onboard)-4 MB, PCMCIA Flash-16 MB or 20 MB, NVRAM-512 KB | |
| Physical Characteristics | ||
| Dimensions (H x W x D) | 5.75 x 17 x 18 in. (14.6 x 43.18 x 46.72 cm) | |
| Weight | 35 lb (15.9 kg) with 2 power supplies, 1 line card, and | |
| AC Power | ||
| Power supply output capacity | ||
| System power dissipation | 155W maximum configuration, 100W typical | |
| System heat dissipation | 850 Btus3/hr | |
| AC-input voltage | 100 to 240 VAC | |
| AC frequency | 47 to 63 Hz | |
| AC-input current | 5.0A maximum at 90 VAC, 3.6A maximum at 115 VAC, and 1.8A at 230 VAC | |
| Power supply output | +5.15V @ 26A, +12V @ 1.5A, +24V @ 0.1A | |
| DC Power | ||
| Power supply output capacity | ||
| System power dissipation | 75W | |
| DC-input voltage Typical range (U.S. and Canada) Typical range (international) | -48 VDC to -60 VDC continuous | |
| DC-input current | 6A | |
| Power supply output | +5.15V @ 30A, +12V @ 1.5A, +24V @ 0.1A | |
| DC power-cable wire gauge | 14 AWG 90×C copper conductors | |
| Airflow | 300 cfm4 through system fan assembly | |
| Agency Approvals Safety EMI5 | | |
|
| ||
Catalyst 5000 and Catalyst 5505 specifications are provided in Table A-2.
| Item | Specification | |
|---|---|---|
| Environmental | ||
| Temperature, ambient operating | 32°F (0°C) to 104°F (40°C) | |
| Temperature, ambient nonoperating and storage | -40 to 167°F (-40 to 75°C) | |
| Humidity (RH), ambient (noncondensing) operating | 10% to 90% | |
| Humidity (RH), ambient (noncondensing) nonoperating and storage | 5% to 95% | |
| Altitude, operating and nonoperating | Sea level to 10,000 ft. (3050 m) | |
| Switching Components | ||
| Backplane | Catalyst 5000-1.2-Gbps Catalyst 5505-3.6-Gbps | |
| Microprocessor | Supervisor Engine I and II-25-MHz 68EC040 for the NMP1 Supervisor Engine III-150-MHz IDT R4700 RISC | |
| Memory |
| |
| Supervisor Engine I (Catalyst 5000 only)
Supervisor Engine II Supervisor Engine III | DRAM2: 20 MB, Flash (onboard)-4 MB, NVRAM3-256 KB DRAM: 16 MB, Flash (onboard)-4 MB, NVRAM-256 KB DRAM: 32 MB, Flash (onboard)-4 MB, PCMCIA Flash-16 MB or 20 MB, NVRAM-512 KB | |
| Physical Characteristics | ||
| Dimensions (H x W x D) | 10.4 x 17.25 x 18.4-in. (26.4 x 43.1 x 46.0 cm) | |
| Weight | Chassis only: 43 lb (19.5 kg) | |
| Power | ||
| Power supply output capacity | 376W maximum (AC- or DC-input power supplies) | |
| System power dissipation (AC and DC supplies) | 350W maximum configuration, 200W typical with maximum configuration | |
| System heat dissipation (AC supply) | 563W (1919 Btus4/hr) | |
| System heat dissipation (DC supply) | 600W (2040 Btus/hr) | |
| AC-input voltage | 100 to 240 VAC wide input with power factor corrector | |
| DC-input voltage Typical range (U.S. and Canada) Typical range (international) | -40.5 VDC to -72 VDC continuous | |
| AC frequency | 47 to 63 Hz | |
| DC power-cable wire gauge | 10 to 12 AWG 90×C copper conductors | |
| AC-input current | 8A maximum at 100 to 127 VAC, 4A maximum at 200 to | |
| DC-input current | 14.0A maximum @ 48V (nominal) | |
| Power supply output | +5.15V @ 70A, +12V @ 2A, +24V @ 0.12A | |
| Airflow | 95 cfm5 through system fan assembly | |
| Agency Approvals Safety EMI6 | | |
Catalyst 5500 specifications are provided in Table A-3.
| Item | Specification | |
|---|---|---|
| Environmental | ||
| Temperature, ambient operating | 32°F (0°C) to 104°F (40°C) | |
| Temperature, ambient nonoperating and storage | -4°F (-20°C) to 149°F (65°C) | |
| Humidity (RH), ambient (noncondensing) operating | 10% to 90% | |
| Humidity (RH), ambient (noncondensing) nonoperating and storage | 5% to 95% | |
| Altitude, operating and nonoperating | Sea level to 10,000 ft (3050 m) | |
| Vibration, operating | 5 to 200 Hz, 0.5 g (1 oct/min) | |
| Vibration, nonoperating | 5 to 200 Hz, 1 g (1 oct/min) | |
| Switching Components | ||
| Backplane | 3.6-Gbps | |
| Microprocessor | Supervisor Engine II: 25-MHz 68EC040 for the NMP1 Supervisor Engine III: 150-MHz IDT R4700 RISC | |
| Memory |
| |
| Supervisor Engine II
Supervisor Engine III | DRAM: 16 MB, Flash (onboard)-4 MB, NVRAM-256 KB DRAM: 32 MB, Flash (onboard)-4 MB, PCMCIA Flash- | |
| Physical Characteristics | ||
| Dimensions (H x W x D) | 25 x 17.25 x 18.4 in. (62.5 x 43.1 x 46.0 cm) | |
| Weight | Chassis only: 61 lb (22.75 kg) | |
| Power | ||
| Power supply output capacity | 1100W maximum (AC- or DC-input power supplies) | |
| System power dissipation | 1100W maximum configuration, 750W typical with maximum configuration | |
| System heat dissipation | 1571W (5360 Btus2/hr) | |
| AC-input voltage | 100 to 240 VAC wide input with power factor corrector | |
| DC-input voltage Typical range (U.S. and Canada) Typical range (international) | -40.5 VDC to -72 VDC continuous | |
| AC frequency | 47 to 63 Hz | |
| DC power-cable wire gauge | 8 AWG 90×C copper conductors | |
| AC-input current | 16A maximum at 100 to 127 VAC, 8A maximum at 200 to | |
| DC-input current | 35A maximum @ 48V (nominal) | |
| Power supply output | 200A @ +5.15V, 6 A @ +12V, 2A @ +24V | |
| Airflow | 285 cfm3 through system fan assembly | |
| Agency Approvals Safety EMI4 | | |
|
|