cc/td/doc/product/lan/cat5000/rel_4_1
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

Specifications

Specifications

This appendix provides technical specifications for the Catalyst 5000 series switches:

Refer to the Catalyst 5000 Series Module Installation Guide for switching module and interface port specifications.

Catalyst 5002

Catalyst 5002 specifications are provided in Table A-1.


Table  A-1: Catalyst 5002 Specifications
Item Specification
Environmental
Temperature, ambient operating

32°F (0°C) to 104°F (40°C)

Temperature, ambient nonoperating and storage

-40 to 158°F (-40 to 70°C)

Humidity (RH), ambient (noncondensing) operating

10% to 90%

Humidity (RH), ambient (noncondensing) nonoperating and storage

5% to 95%

Altitude, operating and nonoperating

Sea level to 10,000 ft. (3050 m)

Switching Components
Backplane

1.2-Gbps

Microprocessor

Supervisor Engine I and II: 25-MHz 68EC040 for the NMP1

Supervisor Engine III: 150-MHz IDT R4700 RISC

Memory

Supervisor Engine I

Supervisor Engine II

Supervisor Engine III

DRAM2: 20 MB, Flash (onboard)-4 MB, NVRAM-256 KB

DRAM: 16 MB, Flash (onboard)-4 MB, NVRAM-256 KB

DRAM: 32 MB, Flash (onboard)-4 MB, PCMCIA Flash-16 MB or 20 MB, NVRAM-512 KB

Physical Characteristics
Dimensions (H x W x D)

5.75 x 17 x 18 in. (14.6 x 43.18 x 46.72 cm)

Weight

35 lb (15.9 kg) with 2 power supplies, 1 line card, and
1 supervisor engine module

AC Power
Power supply output capacity

155W maximum

System power dissipation

155W maximum configuration, 100W typical

System heat dissipation

850 Btus3/hr

AC-input voltage

100 to 240 VAC

AC frequency

47 to 63 Hz

AC-input current

5.0A maximum at 90 VAC, 3.6A maximum at 115 VAC, and 1.8A at 230 VAC

Power supply output

+5.15V @ 26A, +12V @ 1.5A, +24V @ 0.1A

DC Power
Power supply output capacity

175W maximum

System power dissipation

75W

DC-input voltage
Typical range (U.S. and Canada)
Typical range (international)

-48 VDC to -60 VDC continuous
-48 VDC (nominal) -56 VDC (high) -40.5 VDC (low)
-60 VDC (nominal) -72 VDC (high) -55 VDC (low)

DC-input current

6A

Power supply output

+5.15V @ 30A, +12V @ 1.5A, +24V @ 0.1A

DC power-cable wire gauge

14 AWG 90×C copper conductors

Airflow

300 cfm4 through system fan assembly

Agency Approvals
  Safety


  EMI
5


UL6 1950, CSA7-C22.2 No. 950, EN860950, and IEC9 950, TS10 001, AS/NZS11 3260 CE12 Marking

FCC13 Part 15, Class A (CFR14 47) (USA), ICES15-003 Class A (Canada), EN55022 Class A (Europe), CISPR22 Class A (International), AS/NZS 3548 Class A (Australia), and VCCI Class A (Japan) with UTP


EN55022 Class B (Europe), CISPR22 Class B (International), AS/NZS 3548 Class B, and VCCI16 Class B (Japan) with STP cables


1 NMP = network management processor
2 DRAM = dynamic random-access memory
3 Btus = British thermal units
4 cfm = cubic feet per minute
5 EMI = electromagnetic interference
6 UL = Underwriters Laboratory
7 CSA = Canadian Standards Association
8 EN = European Norm
9 IEC = International Electrotechnical Commission
10 TS = Technical Specification
11 AS/NZS = Standards Australia/Standards New Zealand
12 CE = European Compliance
13 FCC = Federal Communications Commission
14 CFR = Code of Federal Regulations
15 ICES = International Commerce Exchange Systems
16 VCCI = Voluntary Control Council for Information Technology Equipment

Catalyst 5000 and Catalyst 5505

Catalyst 5000 and Catalyst 5505 specifications are provided in Table A-2.


Table  A-2: Catalyst 5000 and Catalyst 5505 Specifications
Item Specification
Environmental
Temperature, ambient operating

32°F (0°C) to 104°F (40°C)

Temperature, ambient nonoperating and storage

-40 to 167°F (-40 to 75°C)

Humidity (RH), ambient (noncondensing) operating

10% to 90%

Humidity (RH), ambient (noncondensing) nonoperating and storage

5% to 95%

Altitude, operating and nonoperating

Sea level to 10,000 ft. (3050 m)

Switching Components
Backplane

Catalyst 5000-1.2-Gbps

Catalyst 5505-3.6-Gbps

Microprocessor

Supervisor Engine I and II-25-MHz 68EC040 for the NMP1

Supervisor Engine III-150-MHz IDT R4700 RISC

Memory

Supervisor Engine I (Catalyst 5000 only)

Supervisor Engine II

Supervisor Engine III

DRAM2: 20 MB, Flash (onboard)-4 MB, NVRAM3-256 KB

DRAM: 16 MB, Flash (onboard)-4 MB, NVRAM-256 KB

DRAM: 32 MB, Flash (onboard)-4 MB, PCMCIA Flash-16 MB or 20 MB, NVRAM-512 KB

Physical Characteristics
Dimensions (H x W x D)

10.4 x 17.25 x 18.4-in. (26.4 x 43.1 x 46.0 cm)
Chassis depth including cable guide is 21.64 in. (55.0 cm)

Weight

Chassis only: 43 lb (19.5 kg)
Chassis fully configured with 1 supervisor engine module, 4 switching modules, and 2 power supplies: 84 lb (39 kg)

Power
Power supply output capacity

376W maximum (AC- or DC-input power supplies)

System power dissipation (AC and DC supplies)

350W maximum configuration, 200W typical with maximum configuration

System heat dissipation (AC supply)

563W (1919 Btus4/hr)

System heat dissipation (DC supply) 600W (2040 Btus/hr)
AC-input voltage

100 to 240 VAC wide input with power factor corrector

DC-input voltage
Typical range (U.S. and Canada)
Typical range (international)

-40.5 VDC to -72 VDC continuous
-48 VDC (nominal) -54 VDC (high) -42 VDC (low)
-60 VDC (nominal) -72 VDC (high) -52 VDC (low)

AC frequency

47 to 63 Hz

DC power-cable wire gauge

10 to 12 AWG 90×C copper conductors

AC-input current

8A maximum at 100 to 127 VAC, 4A maximum at 200 to
240 VAC with full configuration (maximum of 0.8 kVA)

DC-input current

14.0A maximum @ 48V (nominal)
11.0A maximum @ 60V (nominal)

Power supply output

+5.15V @ 70A, +12V @ 2A, +24V @ 0.12A

Airflow

95 cfm5 through system fan assembly

Agency Approvals
  Safety


  EMI
6


UL7 1950, CSA8-C22.2 No. 950, EN960950, and IEC10 950, TS11 001, AS/NZS12 3260 CE13 Marking

FCC14 Part 15, Class A (CFR15 47) (USA), ICES16-003 Class A (Canada), EN55022 Class A (Europe), CISPR22 Class A (International), AS/NZS 3548 Class A (Australia), and VCCI Class A (Japan) with UTP


EN55022 Class B (Europe), CISPR22 Class B (International), AS/NZS 3548 Class B, and VCCI17 Class B (Japan) with STP cables


1 NMP = network management processor
2 DRAM = dynamic random-access memory
3 NVRAM = nonvolatile RAM
4 Btus = British thermal units
5 cfm = cubic feet per minute
6 EMI = electromagnetic interference
7 UL = Underwriters Laboratory
8 CSA = Canadian Standards Association
9 EN = European Norm
10 IEC = International Electrotechnical Commission
11 TS = Technical Specification
12 AS/NZS = Standards Australia/Standards New Zealand
13 CE = European Compliance
14 FCC = Federal Communications Commission
15 CFR = Code of Federal Regulations
16 ICES = International Commerce Exchange Systems
17 VCCI = Voluntary Control Council for Information Technology Equipment

Catalyst 5500

Catalyst 5500 specifications are provided in Table A-3.


Table  A-3: Catalyst 5500 Specifications
Item Specification
Environmental
Temperature, ambient operating

32°F (0°C) to 104°F (40°C)

Temperature, ambient nonoperating and storage

-4°F (-20°C) to 149°F (65°C)

Humidity (RH), ambient (noncondensing) operating

10% to 90%

Humidity (RH), ambient (noncondensing) nonoperating and storage

5% to 95%

Altitude, operating and nonoperating

Sea level to 10,000 ft (3050 m)

Vibration, operating

5 to 200 Hz, 0.5 g (1 oct/min)

Vibration, nonoperating

5 to 200 Hz, 1 g (1 oct/min)
200 to 500 Hz, 2 g (1 oct/min)

Switching Components
Backplane

3.6-Gbps
5-Gbps cell-based switching fabric for ATM

Microprocessor

Supervisor Engine II: 25-MHz 68EC040 for the NMP1

Supervisor Engine III: 150-MHz IDT R4700 RISC

Memory

Supervisor Engine II

Supervisor Engine III

DRAM: 16 MB, Flash (onboard)-4 MB, NVRAM-256 KB

DRAM: 32 MB, Flash (onboard)-4 MB, PCMCIA Flash-
16 MB or 20 MB, NVRAM-512 KB

Physical Characteristics
Dimensions (H x W x D)

25 x 17.25 x 18.4 in. (62.5 x 43.1 x 46.0 cm)
Depth including cable guide 21.64 in. (55.0 cm)

Weight

Chassis only: 61 lb (22.75 kg)
Full configuration: 13 switching modules and 2 power supplies, 176 lb (65.65 kg)

Power
Power supply output capacity

1100W maximum (AC- or DC-input power supplies)

System power dissipation

1100W maximum configuration, 750W typical with maximum configuration

System heat dissipation

1571W (5360 Btus2/hr)

AC-input voltage

100 to 240 VAC wide input with power factor corrector

DC-input voltage
Typical range (U.S. and Canada)
Typical range (international)

-40.5 VDC to -72 VDC continuous
-48 VDC (nominal) -54 VDC (high) -42 VDC (low)
-60 VDC (nominal) -72 VDC (high) -52 VDC (low)

AC frequency

47 to 63 Hz

DC power-cable wire gauge

8 AWG 90×C copper conductors

AC-input current

16A maximum at 100 to 127 VAC, 8A maximum at 200 to
240 VAC with full configuration (maximum of 1.8 kVA)

DC-input current

35A maximum @ 48V (nominal)
27A maximum @ 60V (nominal)

Power supply output

200A @ +5.15V, 6 A @ +12V, 2A @ +24V

Airflow

285 cfm3 through system fan assembly

Agency Approvals
  Safety


  EMI
4


UL5 1950, CSA6-C22.2 No. 950, EN760950, and IEC8 950, TS9 001, AS/NZS10 3260 CE11 Marking

FCC12 Part 15, Class A (CFR13 47) (USA), ICES14-003 Class A (Canada), EN55022 Class A (Europe), CISPR22 Class A (International), AS/NZS 3548 Class A (Australia), and VCCI Class A (Japan) with UTP


EN55022 Class B (Europe), CISPR22 Class B (International), AS/NZS 3548 Class B, and VCCI15 Class B (Japan) with STP cables


1 NMP = network management processor
2 Btus = British thermal units
3 cfm = cubic feet per minute
4 EMI = electromagnetic interference
5 UL = Underwriters Laboratory
6 CSA = Canadian Standards Association
7 EN = European Norm
8 IEC = International Electrotechnical Commission
9 TS = Technical Specification
10 AS/NZS = Standards Australia/Standards New Zealand
11 CE = European Compliance
12 FCC = Federal Communications Commission
13 CFR = Code of Federal Regulations
14 ICES = International Commerce Exchange Systems
15 VCCI = Voluntary Control Council for Information Technology Equipment


hometocprevnextglossaryfeedbacksearchhelp
Copyright 1989-1998 © Cisco Systems Inc.