Table A-1: Catalyst 5002 Switch Specifications
Item Specification
Environmental

Temperature, ambient operating

32°F (0°C) to 104°F (40°C)

Temperature, ambient nonoperating and storage

-40 to 158°F (-40 to 70°C)

Humidity (RH), ambient (noncondensing) operating

10% to 90%

Humidity (RH), ambient (noncondensing) nonoperating and storage

5% to 95%

Altitude, operating and nonoperating

Sea level to 10,000 ft. (3050 m)

Switching Components

Backplane

1.2 Gbps

Microprocessor

Supervisor Engines I and II: 25-MHz 68EC040 for the NMP1

Supervisor Engines II G and III G: 37.5-MHz MCF5102 for the NMP

Memory

Supervisor Engine I

Supervisor Engine II

Supervisor Engine II G

Supervisor Engine III G

DRAM2: 20 MB; Flash (onboard)-4 MB; NVRAM-256 KB

DRAM: 16 MB; Flash (onboard)-4 MB;
NVRAM-256 KB

DRAM: 32 MB; Flash (onboard)-8 MB;
NVRAM-256 KB

DRAM: 32 MB; Flash (onboard)-8 MB;
NVRAM-256 KB

Physical Characteristics

Dimensions (H x W x D)

5.75 x 17 x 18 in. (14.6 x 43.18 x 46.72 cm)

Weight

35 lb (15.9 kg) with 2 power supplies, 1 switching module, and 1 supervisor engine

Shock and Vibration

Shock

54 inches per second (1.37 meters per second)

Vibration

0.35 g from 3 to 500 Hz

AC Power without Power Factor Correction

Power supply output capacity

155W maximum

System power dissipation

155W maximum configuration, 120W typical

System heat dissipation

850 Btus3/hr

AC-input voltage

100 to 240 VAC

AC frequency

50 to 60 Hz

AC-input current

5.0A maximum

Power supply output

+5.15V @ 26A, +12V @ 1.5A, +24V @ 0.1A

AC Power with Power Factor Correction

Power supply output capacity

175W maximum

System power dissipation

175W maximum configuration, 100W typical

System heat dissipation

950 Btus/hr

AC-input voltage

90 to 264 VAC autoranging

AC frequency

47 to 63 Hz

AC-input current

3.0A maximum @ 110 VAC, 1.5A maximum @
220 VAC

Power supply output

+5.15V @ 30A, +12V @ 1.5A, +24V @ 0.1A

DC Power

Power supply output capacity

175W maximum

System power dissipation

175W maximum, 120W typical

DC-input voltage
Typical range (U.S. and Canada)
Typical range (International)

-48 VDC to -60 VDC continuous
-48 VDC (nominal) -56 VDC (high) -40.5 VDC (low)
-60 VDC (nominal) -72 VDC (high) -55 VDC (low)

DC-input current

6A

Power supply output

+5.15V @ 30A, +12V @ 1.5A, +24V @ 0.1A

DC power-cable wire gauge

14 AWG 90ºC copper conductors

Airflow

200 lfm4 through system fan assembly

Agency Approvals
  Safety


  EMI
5


UL6 1950, CSA7-C22.2 No. 950, EN860950, and IEC9 950, TS10 001, AS/NZS11 3260, CE12 Marking,
EN 60825, IEC 60825, 21CFR1040

FCC13 Part 15, Class A (CFR14 47) (USA), ICES15-003 Class A (Canada), EN55022 Class A (Europe), CISPR22 Class A (International), AS/NZS 3548 Class A (Australia), and VCCI Class A (Japan) with UTP16


EN55022 Class B (Europe), CISPR22 Class B (International), AS/NZS 3548 Class B, and VCCI17 Class B (Japan) with FTP18 cables

1NMP = network management processor
2DRAM = dynamic random-access memory
3Btus = British thermal units
4lfm = linear feet per minute
5EMI = electromagnetic interference
6UL = Underwriters Laboratory
7CSA = Canadian Standards Association
8EN = European Norm
9IEC = International Electrotechnical Commission
10TS = Technical Specification
11AS/NZS = Standards Australia/Standards New Zealand
12CE = European Compliance
13FCC = Federal Communications Commission
14CFR = Code of Federal Regulations
15ICES = International Commerce Exchange Systems
16UTP = unshielded twisted-pair
17VCCI = Voluntary Control Council for Information Technology Equipment
18FTP = foil twisted-pair

Catalyst 5000 and Catalyst 5505 Switches

The specifications for the Catalyst 5000 and Catalyst 5505 switches are provided in Table A-2.


Table A-2: Catalyst 5000 Switch and Catalyst 5505 Switch Specifications
Item Specification
Environmental

Temperature, ambient operating

32°F (0°C) to 104°F (40°C)

Temperature, ambient nonoperating and storage

-40 to 150ºF (-40 to 70ºC)

Humidity (RH), ambient (noncondensing) operating

10% to 90%

Humidity (RH), ambient (noncondensing) nonoperating and storage

5% to 95%

Altitude, operating and nonoperating

Sea level to 10,000 ft. (3050 m)

Switching Components

Backplane

Catalyst 5000 switch-1.2 Gbps

Catalyst 5505 switch-3.6 Gbps

Switching Components (continued)

Microprocessor

Supervisor Engines I and II: 25-MHz 68EC040 for the NMP1

Supervisor Engine III, Supervisor Engine III F: 150-MHz IDT R4700 RISC

Supervisor Engines II G and III G: 37.5-MHz MCF5102 for the NMP

Memory

Supervisor Engine I (Catalyst 5000 switch only)

Supervisor Engine II

Supervisor Engine II G

Supervisor Engine III

Supervisor Engine III F

Supervisor Engine III G

DRAM2: 20 MB; Flash (onboard)-4 MB; NVRAM3-256 KB

DRAM: 16 MB; Flash (onboard)-4 MB; NVRAM-256 KB

DRAM: 32 MB; Flash (onboard)-8 MB;
NVRAM-256 KB

DRAM: 32 MB; Flash (onboard)-4 MB; Flash PC Card-16 MB or 20 MB; NVRAM-512 KB

DRAM: 32 MB; Flash (onboard)-4 MB;
NVRAM-512 KB

DRAM: 32 MB; Flash (onboard)-8 MB;
NVRAM-256 KB

Physical Characteristics

Dimensions (H x W x D)

10.4 x 17.25 x 18.4 in. (26.4 x 43.1 x 46.0 cm)
Chassis depth including cable guide is 21.64 in.
(55.0 cm)

Weight

Chassis only: 43 lb (19.5 kg)
Chassis fully configured with 1 supervisor engine, 4 switching modules, and 2 power supplies: 84 lb
(39 kg)

Shock and Vibration

Shock

42 inches per second (1.07 meters per second)

Vibration

0.35 g from 3 to 500 Hz

Power

Power supply output capacity

376W maximum (AC-input or DC-input power supplies)

System power dissipation (AC and DC supplies)

350W maximum configuration, 250W typical with maximum configuration

System heat dissipation (AC supply)

563W (1919 Btus4/hr)

System heat dissipation (DC supply)

600W (2040 Btus/hr)

AC-input voltage

100 to 127/200 to 240 VAC wide input with power factor corrector

DC-input voltage
Typical range (U.S. and Canada)
Typical range (International)

-48 VDC to -60 VDC continuous
-48 VDC (nominal) -54 VDC (high) -42 VDC (low)
-60 VDC (nominal) -72 VDC (high) -52 VDC (low)

AC frequency

50 to 60 Hz

DC power-cable wire gauge

10 to 12 AWG 90ºC copper conductors

AC-input current

8/4A with full configuration (maximum of 0.8 kVA)

DC-input current

12.0A maximum @ 48V (nominal)
10.0A maximum @ 60V (nominal)

Power supply output

+5.15V @ 70A, +12V @ 2A, +24V @ 0.12A

Airflow

200 lfm5 through system fan assembly

Agency Approvals
  Safety


  EMI
6


UL7 1950, CSA8-C22.2 No. 950, EN960950, and IEC10 950, TS11 001, AS/NZS12 3260 CE13 Marking,
EN 60825, IEC 60825, 21CFR1040

FCC14 Part 15, Class A (CFR15 47) (USA), ICES16-003 Class A (Canada), EN55022 Class A (Europe), CISPR22 Class A (International), AS/NZS 3548 Class A (Australia), and VCCI Class A (Japan) with UTP17


EN55022 Class B (Europe), CISPR22 Class B (International), AS/NZS 3548 Class B, and VCCI18 Class B (Japan) with FTP19 cables

1NMP = network management processor
2DRAM = dynamic random-access memory
3NVRAM = nonvolatile RAM
4Btus = British thermal units
5lfm = linear feet per minute
6EMI = electromagnetic interference
7UL = Underwriters Laboratory
8CSA = Canadian Standards Association
9EN = European Norm
10IEC = International Electrotechnical Commission
11TS = Technical Specification
12AS/NZS = Standards Australia/Standards New Zealand
13CE = European Compliance
14FCC = Federal Communications Commission
15CFR = Code of Federal Regulations
16ICES = International Commerce Exchange Systems
17UTP = unshielded twisted-pair
18VCCI = Voluntary Control Council for Information Technology Equipment
19FTP = foil twisted-pair

Catalyst 5509 Switch

Catalyst 5509 switch specifications are provided in Table A-3.


Table A-3: Catalyst 5509 Switch Specifications
Item Specification
Environmental

Temperature, ambient operating

32°F (0°C) to 104°F (40°C)

Temperature, ambient nonoperating and storage

-40 to 158°F (-40 to 70°C)

Humidity (RH), ambient (noncondensing) operating

10% to 90%

Humidity (RH), ambient (noncondensing) nonoperating and storage

5% to 95%

Altitude, operating and nonoperating

Sea level to 10,000 ft. (3050 m)

Switching Components

Backplane

3.6 Gbps

Microprocessor

Supervisor Engine II: 25-MHz 68EC040 for the NMP1

Supervisor Engine III, Supervisor Engine III F: 150-MHz IDT R4700 RISC

Supervisor Engines II G and III G: 37.5-MHz MCF5102 for the NMP

Memory

Supervisor Engine II

Supervisor Engine II G

Supervisor Engine III

Supervisor Engine III F

Supervisor Engine III G

DRAM2: 16 MB; Flash (onboard)-4 MB; NVRAM3-256 KB

DRAM: 32 MB; Flash (onboard)-8 MB;
NVRAM-256 KB

DRAM: 32 MB; Flash (onboard)-4 MB; Flash PC Card-16 MB or 20 MB; NVRAM-512 KB

DRAM: 32 MB; Flash (onboard)-4 MB;
NVRAM-512 KB

DRAM: 32 MB; Flash (onboard)-8 MB;
NVRAM-256 KB

Physical Characteristics

Dimensions (H x W x D)

20 x 17.25 x 18.4 in. (50.8 x 43.1 x 46.0 cm)
Chassis depth including cable guide is 21.64 in.
(55.0 cm)

Weight

Chassis only: 55 lb (24.9 kg)

Chassis fully configured with 1 supervisor engine, 4 switching modules, and 2 power supplies: 135 lb (61.2 kg)

Shock and Vibration

Shock

42 inches per second (1.07 meters per second)

Vibration

0.35 g from 3 to 500 Hz

Power

Power supply output capacity

805W maximum (AC-input or DC-input power supplies)

System power dissipation (AC and DC supplies)

805W maximum configuration, 600W typical with maximum configuration

System heat dissipation (AC supply)

1150W (3920 Btus4/hr) maximum

System heat dissipation (DC supply)

1150W (3920 Btus/hr) maximum

AC-input voltage

100 to 240 VAC wide input with power factor corrector

DC-input voltage
Typical range (U.S. and Canada)
Typical range (International)

-48 VDC to -60 VDC continuous
-48 VDC (nominal) -54 VDC (high) -42 VDC (low)
-60 VDC (nominal) -72 VDC (high) -52 VDC (low)

AC frequency

50 to 60 Hz

DC power-cable wire gauge

10 AWG 90ºC copper conductors

AC-input current

12-6A (805W power supply) or 16-7A (1100W power supply)

DC-input current

25.0A (1100W power supply) or 40.0A (1200W power supply)

Power supply output

+5.15V @ 140A, +12V @ 4A, +24V @ 1.5A

Airflow

200 lfm5 through system fan assembly

Agency Approvals
  Safety


  EMI
6


UL7 1950, CSA8-C22.2 No. 950, EN960950, and IEC10 950, TS11 001, AS/NZS12 3260 CE13 Marking,
EN 60825, IEC 60825, 21CFR1040

FCC14 Part 15, Class A (CFR15 47) (USA), ICES16-003 Class A (Canada), EN55022 Class A (Europe), CISPR22 Class A (International), AS/NZS 3548 Class A (Australia), and VCCI Class A (Japan) with UTP17


EN55022 Class B (Europe), CISPR22 Class B (International), AS/NZS 3548 Class B, and VCCI18 Class B (Japan) with FTP19 cables

1NMP = network management processor
2DRAM = dynamic random-access memory
3NVRAM = nonvolatile random-access memory
4Btus = British thermal units
5lfm = linear feet per minute
6EMI = electromagnetic interference
7UL = Underwriters Laboratory
8CSA = Canadian Standards Association
9EN = European Norm
10IEC = International Electrotechnical Commission
11TS = Technical Specification
12AS/NZS = Standards Australia/Standards New Zealand
13CE = European Compliance
14FCC = Federal Communications Commission
15CFR = Code of Federal Regulations
16ICES = International Commerce Exchange Systems
17UTP = unshielded twisted-pair
18VCCI = Voluntary Control Council for Information Technology Equipment
19FTP = foil twisted-pair

Catalyst 5500 Switch

Catalyst 5500 switch specifications are provided in Table A-4.


Table A-4: Catalyst 5500 Switch Specifications
Item Specification
Environmental

Temperature, ambient operating

32°F (0°C) to 104°F (40°C)

Temperature, ambient nonoperating and storage

-40°F (-40°C) to 158°F (70°C)

Humidity (RH), ambient (noncondensing) operating

10% to 90%

Humidity (RH), ambient (noncondensing) nonoperating and storage

5% to 95%

Altitude, operating and nonoperating

Sea level to 10,000 ft (3050 m)

Vibration, operating

5 to 200 Hz, 0.5 g (1 oct/min)

Vibration, nonoperating

5 to 200 Hz, 1 g (1 oct/min)
200 to 500 Hz, 2 g (1 oct/min)

Switching Components

Backplane

3.6 Gbps
5-Gbps cell-based switching fabric for ATM

Switching Components (continued)

Microprocessor

Supervisor Engine II: 25-MHz 68EC040 for the NMP1

Supervisor Engine III, Supervisor Engine III F: 150-MHz IDT R4700 RISC

Supervisor Engines II G and III G: 37.5-MHz MCF5102 for the NMP

Memory

Supervisor Engine II

Supervisor Engine II G

Supervisor Engine III

Supervisor Engine III F

Supervisor Engine III G

DRAM2: 16 MB; Flash (onboard)-4 MB; NVRAM3-256 KB

DRAM: 32 MB; Flash (onboard)-8 MB;
NVRAM-256 KB

DRAM: 32 MB; Flash (onboard)-4 MB; Flash PC Card-16 MB or 20 MB; NVRAM-512 KB

DRAM: 32 MB; Flash (onboard)-4 MB;
NVRAM-512 KB

DRAM: 32 MB; Flash (onboard)-8 MB;
NVRAM-256 KB

Physical Characteristics

Dimensions (H x W x D)

25 x 17.25 x 18.4 in. (62.5 x 43.1 x 46.0 cm)
Depth including cable guide: 21.64 in. (55.0 cm)

Weight

Chassis only: 61 lb (22.75 kg)
Full configuration: 13 switching modules and 2 power supplies, 176 lb (65.65 kg)

Shock and Vibration

Shock

21 inches per second (0.53 meters per second)

Vibration

0.35 g from 3 to 500 Hz

Power

Power supply output capacity

1100W maximum (AC-input or DC-input power supplies)

System power dissipation

1100W maximum configuration, 750W typical with maximum configuration

System heat dissipation

1571W (5360 Btus4/hr)

AC-input voltage

100 to 240 VAC wide input with power factor corrector

DC-input voltage
Typical range (U.S. and Canada)
Typical range (International)

-48 VDC to -60 VDC continuous
-48 VDC (nominal) -54 VDC (high) -42 VDC (low)
-60 VDC (nominal) -72 VDC (high) -52 VDC (low)

AC frequency

50 to 60 Hz

DC power-cable wire gauge

8 AWG 90ºC copper conductors

AC-input current

16-7A with full configuration (maximum of 1.8 kVA)

DC-input current

35A or 40A

Power supply output

200A @ +5.15V, 6 A @ +12V, 2A @ +24V

Airflow

200 lfm5 through system fan assembly

Agency Approvals
  Safety


  EMI
6

UL7 1950, CSA8-C22.2 No. 950, EN960950, and IEC10 950, TS11 001, AS/NZS12 3260 CE13 Marking,
EN 60825, IEC 60825, 21CFR1040

FCC14 Part 15, Class A (CFR15 47) (USA), ICES16-003 Class A (Canada), EN55022 Class A (Europe), CISPR22 Class A (International), AS/NZS 3548 Class A (Australia), and VCCI Class A (Japan) with UTP17


EN55022 Class B (Europe), CISPR22 Class B (International), AS/NZS 3548 Class B, and VCCI18 Class B (Japan) with FTP19 cables

1NMP = network management processor
2DRAM = dynamic random-access memory
3NVRAM = nonvolatile random-access memory
4Btus = British thermal units
5lfm = linear feet per minute
6EMI = electromagnetic interference
7UL = Underwriters Laboratory
8CSA = Canadian Standards Association
9EN = European Norm
10IEC = International Electrotechnical Commission
11TS = Technical Specification
12AS/NZS = Standards Australia/Standards New Zealand
13CE = European Compliance
14FCC = Federal Communications Commission
15CFR = Code of Federal Regulations
16ICES = International Commerce Exchange Systems
17UTP = unshielded twisted-pair
18VCCI = Voluntary Control Council for Information Technology Equipment
19FTP = foil twisted-pair


hometocprevnextglossaryfeedbacksearchhelp
Posted: Tue Sep 26 10:36:14 PDT 2000
Copyright 1989-2000©Cisco Systems Inc.