This appendix provides technical specifications for these Catalyst 5000 family switches:
Refer to the Catalyst 5000 Family Module Installation Guide for switching module and interface port specifications.
Catalyst 5002 switch specifications are provided in Table A-1.
| Item | Specification | |
|---|---|---|
| Environmental |
|
|
Temperature, ambient operating | 32°F (0°C) to 104°F (40°C) | |
Temperature, ambient nonoperating and storage | -40 to 158°F (-40 to 70°C) | |
Humidity (RH), ambient (noncondensing) operating | 10% to 90% | |
Humidity (RH), ambient (noncondensing) nonoperating and storage | 5% to 95% | |
Altitude, operating and nonoperating | Sea level to 10,000 ft. (3050 m) | |
| Switching Components | ||
Backplane | 1.2 Gbps | |
Supervisor Engines I and II: 25-MHz 68EC040 for the NMP1 Supervisor Engines II G and III G: 37.5-MHz MCF5102 for the NMP | ||
| Memory | ||
Supervisor Engine I Supervisor Engine II Supervisor Engine II G Supervisor Engine III G | DRAM2: 20 MB; Flash (onboard)-4 MB; NVRAM-256 KB DRAM: 16 MB; Flash (onboard)-4 MB; DRAM: 32 MB; Flash (onboard)-8 MB; DRAM: 32 MB; Flash (onboard)-8 MB; | |
| Physical Characteristics | ||
5.75 x 17 x 18 in. (14.6 x 43.18 x 46.72 cm) | ||
35 lb (15.9 kg) with 2 power supplies, 1 switching module, and 1 supervisor engine | ||
| Shock and Vibration |
| |
Shock | 54 inches per second (1.37 meters per second) | |
Vibration | 0.35 g from 3 to 500 Hz |
|
| AC Power without Power Factor Correction |
|
|
Power supply output capacity | ||
System power dissipation | 155W maximum configuration, 120W typical | |
850 Btus3/hr | ||
AC-input voltage | 100 to 240 VAC | |
50 to 60 Hz | ||
AC-input current | 5.0A maximum | |
Power supply output | +5.15V @ 26A, +12V @ 1.5A, +24V @ 0.1A | |
| AC Power with Power Factor Correction |
|
|
Power supply output capacity | ||
System power dissipation | 175W maximum configuration, 100W typical | |
950 Btus/hr | ||
AC-input voltage | 90 to 264 VAC autoranging | |
47 to 63 Hz | ||
AC-input current | 3.0A maximum @ 110 VAC, 1.5A maximum @ | |
Power supply output | +5.15V @ 30A, +12V @ 1.5A, +24V @ 0.1A | |
| DC Power |
|
|
Power supply output capacity | 175W maximum | |
System power dissipation | 175W maximum, 120W typical | |
DC-input voltage | -48 VDC to -60 VDC continuous | |
DC-input current | 6A | |
Power supply output | +5.15V @ 30A, +12V @ 1.5A, +24V @ 0.1A | |
DC power-cable wire gauge | 14 AWG 90ºC copper conductors | |
| Airflow | 200 lfm4 through system fan assembly | |
| Agency Approvals Safety EMI5 | | |
The specifications for the Catalyst 5000 and Catalyst 5505 switches are provided in Table A-2.
| Item | Specification | |
|---|---|---|
| Environmental | ||
Temperature, ambient operating | 32°F (0°C) to 104°F (40°C) | |
Temperature, ambient nonoperating and storage | -40 to 150ºF (-40 to 70ºC) | |
Humidity (RH), ambient (noncondensing) operating | 10% to 90% | |
Humidity (RH), ambient (noncondensing) nonoperating and storage | 5% to 95% | |
Altitude, operating and nonoperating | Sea level to 10,000 ft. (3050 m) | |
| Switching Components | ||
Backplane | Catalyst 5000 switch-1.2 Gbps Catalyst 5505 switch-3.6 Gbps | |
| Switching Components (continued) | ||
Supervisor Engines I and II: 25-MHz 68EC040 for the NMP1 Supervisor Engine III, Supervisor Engine III F: 150-MHz IDT R4700 RISC Supervisor Engines II G and III G: 37.5-MHz MCF5102 for the NMP | ||
| Memory |
| |
Supervisor Engine I (Catalyst 5000 switch only) Supervisor Engine II Supervisor Engine II G Supervisor Engine III Supervisor Engine III F Supervisor Engine III G | DRAM2: 20 MB; Flash (onboard)-4 MB; NVRAM3-256 KB DRAM: 16 MB; Flash (onboard)-4 MB; NVRAM-256 KB DRAM: 32 MB; Flash (onboard)-8 MB; DRAM: 32 MB; Flash (onboard)-4 MB; Flash PC Card-16 MB or 20 MB; NVRAM-512 KB DRAM: 32 MB; Flash (onboard)-4 MB; DRAM: 32 MB; Flash (onboard)-8 MB; | |
| Physical Characteristics | ||
10.4 x 17.25 x 18.4 in. (26.4 x 43.1 x 46.0 cm) | ||
Chassis only: 43 lb (19.5 kg) | ||
| Shock and Vibration |
|
|
Shock | 42 inches per second (1.07 meters per second) | |
Vibration | 0.35 g from 3 to 500 Hz |
|
| Power | ||
376W maximum (AC-input or DC-input power supplies) | ||
System power dissipation (AC and DC supplies) | 350W maximum configuration, 250W typical with maximum configuration | |
563W (1919 Btus4/hr) | ||
System heat dissipation (DC supply) | 600W (2040 Btus/hr) |
|
AC-input voltage | 100 to 127/200 to 240 VAC wide input with power factor corrector | |
DC-input voltage | -48 VDC to -60 VDC continuous | |
50 to 60 Hz | ||
DC power-cable wire gauge | 10 to 12 AWG 90ºC copper conductors | |
AC-input current | 8/4A with full configuration (maximum of 0.8 kVA) | |
DC-input current | 12.0A maximum @ 48V (nominal) | |
Power supply output | +5.15V @ 70A, +12V @ 2A, +24V @ 0.12A | |
| Airflow | 200 lfm5 through system fan assembly | |
| Agency Approvals Safety EMI6 | | |
Catalyst 5509 switch specifications are provided in Table A-3.
| Item | Specification | |
|---|---|---|
| Environmental | ||
Temperature, ambient operating | 32°F (0°C) to 104°F (40°C) | |
Temperature, ambient nonoperating and storage | -40 to 158°F (-40 to 70°C) | |
Humidity (RH), ambient (noncondensing) operating | 10% to 90% | |
Humidity (RH), ambient (noncondensing) nonoperating and storage | 5% to 95% | |
Altitude, operating and nonoperating | Sea level to 10,000 ft. (3050 m) | |
| Switching Components | ||
Backplane | 3.6 Gbps | |
Supervisor Engine II: 25-MHz 68EC040 for the NMP1 Supervisor Engine III, Supervisor Engine III F: 150-MHz IDT R4700 RISC Supervisor Engines II G and III G: 37.5-MHz MCF5102 for the NMP | ||
| Memory | ||
Supervisor Engine II Supervisor Engine II G Supervisor Engine III Supervisor Engine III F Supervisor Engine III G | DRAM2: 16 MB; Flash (onboard)-4 MB; NVRAM3-256 KB DRAM: 32 MB; Flash (onboard)-8 MB; DRAM: 32 MB; Flash (onboard)-4 MB; Flash PC Card-16 MB or 20 MB; NVRAM-512 KB DRAM: 32 MB; Flash (onboard)-4 MB; DRAM: 32 MB; Flash (onboard)-8 MB; | |
| Physical Characteristics | ||
20 x 17.25 x 18.4 in. (50.8 x 43.1 x 46.0 cm) | ||
Chassis only: 55 lb (24.9 kg) Chassis fully configured with 1 supervisor engine, 4 switching modules, and 2 power supplies: 135 lb (61.2 kg) | ||
| Shock and Vibration | ||
Shock | 42 inches per second (1.07 meters per second) | |
Vibration | 0.35 g from 3 to 500 Hz |
|
| Power | ||
805W maximum (AC-input or DC-input power supplies) | ||
System power dissipation (AC and DC supplies) | 805W maximum configuration, 600W typical with maximum configuration | |
1150W (3920 Btus4/hr) maximum | ||
System heat dissipation (DC supply) | 1150W (3920 Btus/hr) maximum | |
AC-input voltage | 100 to 240 VAC wide input with power factor corrector | |
DC-input voltage | -48 VDC to -60 VDC continuous | |
50 to 60 Hz | ||
DC power-cable wire gauge | 10 AWG 90ºC copper conductors | |
AC-input current | 12-6A (805W power supply) or 16-7A (1100W power supply) | |
DC-input current | 25.0A (1100W power supply) or 40.0A (1200W power supply) | |
Power supply output | +5.15V @ 140A, +12V @ 4A, +24V @ 1.5A | |
| Airflow | 200 lfm5 through system fan assembly | |
| Agency Approvals Safety EMI6 | | |
Catalyst 5500 switch specifications are provided in Table A-4.
| Item | Specification | |
|---|---|---|
| Environmental |
|
|
Temperature, ambient operating | 32°F (0°C) to 104°F (40°C) | |
Temperature, ambient nonoperating and storage | -40°F (-40°C) to 158°F (70°C) | |
Humidity (RH), ambient (noncondensing) operating | 10% to 90% | |
Humidity (RH), ambient (noncondensing) nonoperating and storage | 5% to 95% | |
Altitude, operating and nonoperating | Sea level to 10,000 ft (3050 m) | |
Vibration, operating | 5 to 200 Hz, 0.5 g (1 oct/min) | |
Vibration, nonoperating | 5 to 200 Hz, 1 g (1 oct/min) | |
| Switching Components | ||
Backplane | 3.6 Gbps | |
| Switching Components (continued) | ||
Supervisor Engine II: 25-MHz 68EC040 for the NMP1 Supervisor Engine III, Supervisor Engine III F: 150-MHz IDT R4700 RISC Supervisor Engines II G and III G: 37.5-MHz MCF5102 for the NMP | ||
| Memory |
| |
Supervisor Engine II Supervisor Engine II G Supervisor Engine III Supervisor Engine III F Supervisor Engine III G | DRAM2: 16 MB; Flash (onboard)-4 MB; NVRAM3-256 KB DRAM: 32 MB; Flash (onboard)-8 MB; DRAM: 32 MB; Flash (onboard)-4 MB; Flash PC Card-16 MB or 20 MB; NVRAM-512 KB DRAM: 32 MB; Flash (onboard)-4 MB; DRAM: 32 MB; Flash (onboard)-8 MB; | |
| Physical Characteristics | ||
25 x 17.25 x 18.4 in. (62.5 x 43.1 x 46.0 cm) | ||
Chassis only: 61 lb (22.75 kg) | ||
| Shock and Vibration |
|
|
Shock | 21 inches per second (0.53 meters per second) | |
Vibration | 0.35 g from 3 to 500 Hz | |
| Power | ||
1100W maximum (AC-input or DC-input power supplies) | ||
System power dissipation | 1100W maximum configuration, 750W typical with maximum configuration | |
1571W (5360 Btus4/hr) | ||
AC-input voltage | 100 to 240 VAC wide input with power factor corrector | |
DC-input voltage | -48 VDC to -60 VDC continuous | |
50 to 60 Hz | ||
DC power-cable wire gauge | 8 AWG 90ºC copper conductors | |
AC-input current | 16-7A with full configuration (maximum of 1.8 kVA) | |
DC-input current | 35A or 40A | |
Power supply output | 200A @ +5.15V, 6 A @ +12V, 2A @ +24V | |
| Airflow | 200 lfm5 through system fan assembly | |
| Agency Approvals Safety EMI6 | UL7 1950, CSA8-C22.2 No. 950, EN960950, and IEC10 950, TS11 001, AS/NZS12 3260 CE13 Marking, | |
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Tue Sep 26 10:36:14 PDT 2000