cc/td/doc/product/lan/cat4000
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

Specifications

Specifications

This appendix provides cable and technical specifications for the Catalyst 4912G switch.

Console Port

The console port is an RJ-45 receptacle. The Request To Send (RTS) signal tracks the state of the Clear To Send (CTS) input. Table A-1 lists the console port pinouts.


Table A-1: Console Port Pinouts
Pin Signal Direction Description

1

RTS

output

request to send

2

DTR

output

data terminal ready

3

TXD

output

transmit data

4

GND

5

GND

6

RXD

input

receive data

7

DSR

input

data set ready

8

CTS

input

clear to send

10BaseT Management Port

The 10BaseT port is an RJ-45 receptacle with a Link Status LED. Table A-2 lists the 10BaseT port pinouts.


Table A-2: 10BaseT Port Pinouts
Pin Signal Direction Description

1

RXDP

input

receive data

2

RXDN

input

receive data

3

TXDP

output

transmit data

4

unused

5

unused

6

TXDN

output

transmit data

7

unused

8

unused

Catalyst 4912G Switch Specifications

Catalyst 4912G switch specifications are provided in Table A-3.


Table A-3: Catalyst 4912G Switch Specifications
Item Specification

Environmental

Temperature
ambient operating

32°F (0°C) to 104°F (40°C)

Temperature
ambient nonoperating and storage

-40 to 167°F (-40 to 75°C)

Humidity (RH), ambient (noncondensing) operating

10% to 90%

Humidity (RH), ambient (noncondensing) nonoperating and storage

5% to 95%

Altitude
operating and nonoperating

-60 to 4000 m

Switching Components

Backplane

12 Gbps full duplex

Microprocessor

150-MHz R5000 RISC-Y2K Compliant

Memory

64-MB SDRAM, 12-MB Flash (onboard), 512-KB NVRAM,
8-MB synchronous SRAM, 256 Bytes serial EEROM

Physical Characteristics

Dimensions (H x W x D)

2.625 x 17.5 x 15 in. (6.6 x 44 x 38 cm)

Weight

13 lb (5.9 kg)

AC Power

Power supply output

120W

System power dissipation

189W

AC-input

2.5A maximum @ 100 VAC
1.3A maximum @ 240VAC

AC frequency

50 to 60 Hz

KVA rating

0.20 KVA

Airflow

Right side in, left side out

Standards Compliance

Compliance

CE Marking

Safety

UL1 1950, CSA2-C22.2 No. 950, EN360950, IEC4 950, TS5 001, AS/NZS6 3260

EMI7

FCC8 Class A (CFR9 47, part 15), ICES10-003 Class A, EN55022 Class A, CISPR22 Class A, AS/NZS 3548 Class A, and VCCI11 Class A with FTP12 cables


EN55022 Class B, CISPR22 Class B, AS/NZS 3548 Class B, and VCCI Class B with FTP cables

1UL = Underwriters Laboratory.
2CSA = Canadian Standards Association.
3EN = European Norm.
4IEC = International Electrotechnical Commission.
5TS = Technical Standard.
6AS/NZS = Australian/New Zealand Standard.
7EMI = electromagnetic interference.
8FCC = Federal Communications Commission.
9CFR = Code of Federal Regulations.
10ICES = International Commerce Exchange Systems.
11VCCI = Voluntary Control Council for Information Technology Equipment.
12FTP = foil twisted-pair.


hometocprevnextglossaryfeedbacksearchhelp