This appendix provides cable and technical specifications for the Catalyst 4003 and 4006 switches.
The Catalyst 4003 switch has a 10BaseT Ethernet management port. The Catalyst 4006 switch has a 10/100BaseT Ethernet management port. Both the Catalyst 4003 and 4006 Ethernet management ports have DTE RJ-45 receptacles and a STATUS LED. Table A-1 lists the Ethernet management port pinouts for the Catalyst 4003 and 4006 switches.
| Pin | Signal | Direction | Description |
|---|---|---|---|
1 | RXDP | input | receive data |
2 | RXDN | input | receive data |
3 | TXDP | output | transmit data |
4 | unused |
|
|
5 | unused |
|
|
6 | TXDN | output | transmit data |
7 | unused |
|
|
8 | unused |
|
|
The console port use a DB-25 connector and supports DTR, DSR, CTS, and RTS handshake signals. Table A-2 lists the console port pinouts for the Catalyst 4003 switch.
| Pin | Signal | Direction | Description |
|---|---|---|---|
1 | Ground |
|
|
2 | RXD | input | receive data |
3 | TXD | output | transmit data |
4 | CTS | input | clear to send |
5 | RTS | output | request to send |
7 | Ground |
|
|
8 | DTR | output | data terminal ready |
20 | DSR | input | data set ready |
The console port uses an RJ-45 connector and supports DTR and DSR handshake signals. Table A-3 lists the console port pinouts for the Catalyst 4006 switch.
| Pin | Signal | Direction | Description |
|---|---|---|---|
1 | RTS | output | request to send |
2 | DTR | output | data terminal ready |
3 | TXD | output | transmit data |
4 | Ground |
|
|
5 | Ground |
|
|
6 | RXD | input | receive data |
7 | DSR | input | data set ready |
8 | CTS | input | clear to send |
Table A-4 lists the Catalyst 4003 switch specifications.
| Item | Specification | |
|---|---|---|
| Environmental |
|
|
Temperature | 32°F (0°C) to 104°F (40°C) | |
Temperature | -40 to 167°F (-40 to 75°C) | |
Humidity (RH), ambient (noncondensing) operating | 10% to 90% | |
Humidity (RH), ambient (noncondensing) nonoperating and storage | 5% to 95% | |
Altitude | -60 to 4000 meters | |
| Switching Components | ||
Backplane | 12-Gbps full duplex | |
Supervisor engine: 150-MHz R5000 RISC | ||
| Memory |
| |
Supervisor engine | SDRAM: 32 MB on board, 32 MB DIMM (1Mx4x72, 168-pin, 100 MHz, non-registered, 3.3V), 16 MB Flash, 512 KB NVRAM | |
| Physical Characteristics | ||
10.50 x 17.25 x 11.81 in. (26.6 x 43.7 x 30 cm) | ||
Minimum weight: 27.5 lb (12 kg) | ||
| AC Power | ||
Power supply output capacity | ||
Power supply output current | +12V @ 33.3A (maximum) | |
AC-input voltage | 100 to 240 VAC | |
50 to 60 Hz | ||
AC-input current | 6.0A maximum @ 100 VAC 60 Hz | |
KVA rating | 0.58 KVA |
|
Heat Dissipation | 530W maximum (1800 BTUs per hour) | |
| DC Power | ||
Power supply output capacity | ||
Power supply output current | +12V @ 33.3A (maximum) | |
DC-input voltage | -40.5 to -72 VDC | |
DC-input current | 11.0A maximum @ -48 VDC | |
KVA rating | 0.53 KVA |
|
Heat dissipation | 530W maximum (1800 BTUs per hour) | |
Input wiring | AWG 12 (recommended), AWG 10 (maximum) | |
| Airflow |
| |
Switch | right to left |
|
Power supply | front to back |
|
| Agency Approvals |
|
|
| Safety EMC1 | UL2 1950, CSA3-C22.2 No. 950, EN460950, | |
Table A-5 lists the Catalyst 4006 switch specifications.
| Item | Specification | |
|---|---|---|
| Environmental |
|
|
Temperature | 32°F (0°C) to 104°F (40°C) | |
Temperature | -40 to 167°F (-40 to 75°C) | |
Humidity (RH), ambient (noncondensing) operating | 10% to 90% | |
Humidity (RH), ambient (noncondensing) nonoperating and storage | 5% to 95% | |
Altitude | | |
| Switching Components | ||
Backplane | 32-Gbps full duplex | |
Supervisor engine: 150-MHz R5000 RISC | ||
| ||
Supervisor engine | SDRAM: 64-MB DIMM (2Mx4x72, 168-pin, 100 MHz, non-registered, 3.3V), 16 MB Flash, 1 MB NVRAM | |
| Physical Characteristics | ||
15.75 x 17.25 x 11.81 in. (40 x 43.7 x 30 cm) | ||
Minimum weight: 31 lb (14.0 kg) | ||
| AC Power | ||
Power supply output capacity | 400W maximum per power supply; 725W maximum with two power supplies | |
Power supply output current | +12V @ 33.3A (maximum) | |
AC-input voltage | 100 to 240 VAC | |
50 to 60 Hz | ||
AC-input current | 6.0A maximum @ 100 VAC 60 Hz per power supply | |
KVA rating | 0.58 KVA |
|
Heat Dissipation | 725W maximum (3090 BTUs per hour) | |
| DC Power | ||
Power supply output capacity | ||
Power supply output current | +12V @ 33.3A (maximum) | |
DC-input voltage | -40.5 to -72 VDC | |
DC-input current | 11.0A maximum @ -48 VDC | |
KVA rating | 0.53 KVA |
|
Heat dissipation | 530W maximum (1800 BTUs per hour) | |
Input wiring | AWG 12 (recommended), AWG 10 (maximum) | |
| Airflow | ||
Switch | right to left |
|
Power supply | front to back |
|
| Agency Approvals |
|
|
| Safety EMC1 | UL2 1950, CSA3-C22.2 No. 950, EN460950, | |
Table A-6 provides specifications for the Catalyst 4003 and 4006 switching modules.
| Item | Specification |
|---|---|
| Physical Characteristics |
|
| 1.75 x 14.4 x 10.5 in. (44 x 366 x 267 mm) |
| 4.8 lb. (2.2 kg) |
| Environmental |
|
| 32 to 104ºF (0 to 40ºC) |
| -40 to 167ºF (-40 to 75ºC) |
| 10 to 90 percent, noncondensing |
| Connectors |
|
| 24-ports; 24 MT-RJ connectors; MMF |
| 48-ports; 48 RJ-45 connectors; Category 5 UTP1 |
| 48-ports; 4 RJ-21 connectors; Category 5 UTP |
| Connectors |
|
| 32-ports; 32 RJ-45 connectors; Category 5 UTP |
| 32-ports; 32 RJ-45 connectors; Category 5 UTP |
| 32-ports; 32 RJ-45 connectors; Category 5 UTP, uplink module |
| 6-ports; 6 GBICs, SC-type connectors; MMF or SMF |
| 12-ports; 12 RJ-45 connectors; Category 5 UTP |
| 18-ports; 18 GBICs, SC-type connectors; MMF or SMF |
| 1unshielded twisted-pair |
![]()
![]()
![]()
![]()
![]()
![]()
![]()