Installing the Switch in a Rack

Installing the Switch in a Rack


Warning Before you install, operate, or service the system, read the Site Preparation and Safety Guide. This guide contains important safety information you should know before working with the system.

This chapter describes how to install Catalyst 4003 switches and Catalyst 4006 switches in a rack. For first-time installations, perform the procedures in the following sections in the order listed:


Note Before starting the installation procedures in this chapter, complete the site-planning checklist in "Site Planning."


Note For information on installing the supervisor engine and switching modules and verifying switch operation, see "Installing the Modules." For information on configuring the switching modules, refer to the Software Configuration Guide for your switch.

Checking the Shipping Container Contents


Note Do not discard the shipping container when you unpack the switch. Flatten the shipping cartons and store them. You will need the container if you need to move or ship the switch in the future. Repacking instructions are provided in "Repacking a Switch."

Follow these steps to check the contents of the shipping container:


Step 1 Check the contents of the accessories box against the Accessories Box Components Checklist and the packing slip. Verify that you received all listed equipment, which should include the following:

Step 2 Check the switching modules in each slot. Ensure that the configuration matches the packing list and that all the specified interfaces are included.


Rack-Mounting the Switch

A standard rack-mount kit is included for mounting the switch in a standard 19-inch (48.3 cm) equipment rack with two unobstructed outer posts, with a nominal depth (between the front and rear mounting posts) of 19.25 inches (48.9 cm) and a maximum depth of 32 inches (81.3 cm). This kit is not suitable for racks with obstructions (such as a power strip) that could impair access to switch FRUs.


Caution Before installing the chassis in a rack, read the "Rack-Mounting the System" section in the Site Preparation and Safety Guide to familiarize yourself with the proper site and environmental conditions. Failure to read and follow these guidelines could lead to an unsuccessful installation and possible damage to the system and components.

Required Installation Tools

The following tools and equipment are required to install the chassis in a rack:


Note For more information about ESD, refer to the Site Preparation and Safety Guide.

Rack-Mounting Catalyst 4003 and 4006 Switches

Follow these steps to install Catalyst 4003 and 4006 switches in a rack:


Step 1 Prepare for installation as follows:


Table 3-1: Rack-Mount Kit Checklist
Quantity Part Description

2

L brackets

6

M4 Phillips pan-head screws

6

12-24 x 3/4-inch Phillips binder-head screws

Step 2 Install the L brackets, which connect the chassis to the rack, as follows:

See Figure 3-1 for the Catalyst 4003 switch or Figure 3-2 for the Catalyst 4006 switch.

Note Figure 3-1 and Figure 3-2 show the L brackets being installed on the front edge of the switch chassis. If necessary, you can also install the L brackets on the rear edge of the switch chassis.


Figure 3-1: Attaching the L Brackets to the Catalyst 4003 Switch



Figure 3-2:
Attaching the L Brackets to the Catalyst 4006 Switch


See Figure 3-3 for the Catalyst 4003 switch or Figure 3-4 for the Catalyst 4006 switch.

Figure 3-3: Attaching the Cable Guide to the Catalyst 4003 Switch



Figure 3-4:
Attaching the Cable Guide to the Catalyst 4006 Switch



Note Some equipment racks provide a power strip along the length of one of the rear posts. If the rack has this feature, consider the position of the strip when planning fastener points. Before installing the L brackets on the chassis, determine whether to install the chassis from the front or the rear of the rack.

Step 3 Install the chassis in the rack as follows:

See Figure 3-5 for the Catalyst 4003 switch or Figure 3-6 for the Catalyst 4006 switch.

Figure 3-5: Installing a Catalyst 4003 Switch in the Rack



Figure 3-6:
Installing a Catalyst 4006 Switch in the Rack


Step 4 Check the ejector levers to ensure that the supervisor engine and the switching module are installed securely.

Step 5 Tighten any loose captive installation screws on the supervisor engine and the switching module.

Step 6 Connect the power supply cords. The switch powers up when the cords are connected.

This completes the installation of the Catalyst 4003 and 4006 switches.