|
|
March 8, 2000
This document describes the problems fixed in Catalyst 3900 switch main image Release 4.1(2) and in ATM firmware image Release 1.2(5). It also lists the known problems for these releases and contains information about the Catalyst 3900 and Catalyst 3920 Token Ring switches that was not included in the user guides. This document is available on the Cisco Connection Documentation CD-ROM or in print.
Sections in this document include the following:
The Catalyst Token Ring switch Release 4.1(x) is a CCO only release. Therefore, to get a copy of the Catalyst 3900 Token Ring Switch User Guide that lists and describes each of the new features that are available in Release 4.1(x), you must either download the PDF files of the user guide from CCO or order a printed and bound copy of the manual through Cisco MarketPlace.
When ordering a printed and bound copy of the user guide through the Cisco MarketPlace, specify one of the following part numbers, depending on the manual you are ordering:
This section lists the problems that have been resolved in the Catalyst 3900 series main image Release 4.1(2) and in Release 1.2(5) of the ATM firmware image.
The following is a list of problems found in the Catalyst 3900 series main image that have been resolved in Release 4.1(2).
| Problem Identifier | Problem Description |
|---|---|
CSCdk46393 | Executing a TFTP upload might fail with the message "Loading box aborted operation." This problem occurs when a TFTP failure has occurred (for example when the TFTP server is down). Once this problem occurs, all TFTP upload or download attempts fail with the same message. |
CSCdm40526 | If an explorer packet destined for an ISL-attached Catalyst 3900 is bridged between Token VLANs via a Catalyst 5000 RSM, the receiving Catalyst 3900 incorrectly caches the originator's RIF. This problem results in no IP connectivity and only occurs when VLAN bridging is configured between Token Ring VLANs via the RSM. |
CSCdm88900 | In a stack configuration, changing the port state of multiple ports on the same switch via the console might result in the port state reverting back to its original setting. This problem occurs when the port state is enabled or disabled for multiple ports within a 10-second time period. |
CSCdm93977 | Removing the primary cable of an ISL channel might cause the switch to reboot. This problem causes a temporary loss of service. |
CSCdm93993 | Deleting a VLAN that contains a port that is on an ATM uplink module causes the Catalyst 3900 switch to reboot. This problem causes a temporary loss of service. |
CSCdp05226 | Allow destination MAC address filters work correctly for frames which are switched to other ports within the same TrCRF, however, frames which should be switched to ports in other TrCRFs in the same TrBRF are incorrectly dropped. With this problem, connectivity to stations in other TrCRFs that have allow destination MAC address filters configured is not possible. |
CSCdp05265 | In a back-to-back Catalyst stack consisting of two switches (box 1 and box 2), connectivity between stations connected to the ports on box 2 might be lost after box 1 is powered down. Sometimes, connectivity may also be lost after box 1 is powered down and then powered back on. This problem does not occur if the switches are connected to a Catalyst Matrix. |
CSCdp05944 | In a stand-alone switch or stack configuration in which an ISL uplink is configured, the Port Spanning Tree Parameters panel might display the incorrect STP mode for ISL ports. This problem occurs when one or more of the following events occur: a port cost is reconfigured, an ISL port is disconnected and reconnected, or an ISL port is reconfigured. |
CSCdp12173 | In a stack configuration in which a Catalyst 3900 with two or more ISL uplinks is stacked with a Catalyst 3920 or a Catalyst 3900 with a four-port Token Ring expansion module and a ring number has not been configured for the default TrBRF (1005), explorer frames received on one of the ISL ports on the default TrBRF are not forwarded out another ISL port. This problem might result in the loss of connectivity for source-route bridged stations. |
CSCdp14597 | In a Catalyst 3900 in which an ISL uplink is configured, assigning a port that belongs to an existing TrCRF to a new TrCRF might cause the port to become blocked (viewable on the Current Spanning Tree Information for a TrBRF and TrCRF panels). This problem causes a connectivity loss on the TrCRf. |
CSCdp33032 | Even when the backup TrCRF feature is working properly on the Catalyst 3900, the following message might display on the console: DRIP: VLAN 603, Addr1=00-05-77-02-ce-00, Addr2=00-05-77-02-ba-00 - Active Conflict with VLAN |
CSCdp54454 | Configuring redundant ISL Channels might cause an unrecoverable spanning-tree loop to occur. |
CSCdp56842 | ISL frames that are received with a destination VLAN of a TrBRF and a destination MAC address of the all F broadcast address or the Token Ring multicast address are not forwarded to ports on other switches if the ring number has not been configured. |
CSCdp93265 | Configuring an ISL Channel on a secondary switch in a stack configuration in which the primary switch contains ISL ports might cause the channel to operate incorrectly when the links in the channel fail. This problem might cause spanning tree loops in the network. |
CSCdp97143 | In an environment in which a large number of VLANs exist and VTP pruning is enabled on a switch, a TrBRF on that switch might be incorrectly pruned even if there are local forwarding ports in the TrBRF. This problem causes stations on the switch to be unable to communicate with stations on other switches that are in the same TrBRF. To determine the pruning state of a TrBRF, access the VTP Pruning Status panel by selecting VTP Pruning VLAN Status on the Port x ISL Statistics panel. |
The following is a list of problems found in the Catalyst 3900 ATM firmware image that have been resolved in the Release 1.2(5).
| Problem Identifier | Problem Description |
|---|---|
CSCdk48384 | When defining a traffic profile to use for mapping outgoing traffic for an ATM connection, setting the VCC Type parameter on the Traffic Profile Mapping panel to Any does not use the profile for any VCC type. Instead, the default traffic profile is used by VCCs when the VCC Type parameter is set to Any. However, setting the VCC Type to DataDirect will apply the traffic profile map to any VCC type. |
CSCdm01728 | In rare circumstances, the processing of Address Resolution Protocol (ARP) messages might cause a loss of service for the ATM module. This problem results connectivity loss across the ATM network. The local Token Ring network connectivity is not affected. |
CSCdm47776 | After extended periods of uninterrupted operation, a Catalyst 3900 switch might begin to truncate (and therefore corrupt) frames that it receives from the ATM network that are to be forwarded to the local network. |
CSCdm92419 | In large network configurations in which many TrCRFs are configured, assigning an ATM module to a TrCRF might result in the LEC associated with that TrCRF not connecting with LANE services. When this problem occurs, the Status field (located on the ATM LEC Setup panel) displays Going Up and never progresses to Up or Forwarding mode. Also, when this problem occurs, no traffic passes to the ATM network for that TrCRF. |
CSCdm92420
| Under light traffic loads, the forwarding of a packet out of an ATM module might be delayed by a Catalyst 3900 switch until another packet is sent out of the module. This problem results in sporadic traffic flow and slow throughput for transport protocols that have long timeouts. |
This section lists the currently known problems in Release 4.1(2).
Problem: Addresses across the stack are not distributed on TokenChannel ports (CSCdm32568)
Problem: Loss of power to a Catalyst Matrix causes STP to malfunction (CSCdm62365)
Problem: Powering off a Catalyst Matrix might cause the loss of VTP VLAN configuration information on secondary switches (CSCdm64562)
Problem: IP over ISL uses a ring number of zero if the ring number has not been manually configured (CSCdm67270)
Problem: The status of a disabled ISL port might display as up and inserted (CSCdp78073)
Problem: Cisco Discovery Protocol neighbors are not being discovered in Catalyst stacks (CSCdp88897)
This section documents the features that have been added to Catalyst 3900 Token Ring software releases 4.1(x). This section contains the following information:
The following new feature has been added to the Catalyst 3900 Token Ring software Release 4.1(2).
The option to configure the insert LED to blink on disabled ports has been added to the Switch Configuration panel. By configuring the insert LED to blink on ports that are disabled, you can visually identify which ports are currently disabled. When you configure the insert LEDs to blink on disabled ports, if the switch is part of a stack, the setting applies to all switches in the stack. If you enable and then disable this feature, the insert LEDs on the disabled ports will continue to blink until the switch is rebooted.
To configure the insert LED to blink on ports that are disabled, complete the following steps:
Step 1 Select Switch Configuration on the Configuration menu. The Switch Configuration panel is displayed.
Step 2 Select the Blink Disabled Port LEDs option and press Enter.
Step 3 Select Yes if you want the insert LEDs to blink on disabled ports. Select No if you do not want the insert LEDs to blink on disabled ports. The default is No.
Step 4 Select Return to save your changes and to exit the Switch Configuration panel.
The following new features have been added to the Catalyst 3900 Token Ring software Release 4.1(1). For detailed information about each new feature, including how to configure them, refer to the Release 4.1(1) version of the appropriate user guide.
A feature of VTP, VTP pruning enhances the use of network bandwidth by reducing unnecessary flooded traffic (for example, broadcast and multicast traffic). VTP pruning increases the available bandwidth by restricting flooded traffic to only those ISL trunk links that the traffic must use to access the appropriate network devices. By default, VTP pruning is disabled on Catalyst 3900 switches.
The Catalyst 3900 switch software Release 4.1(1) and later performs error detection and isolation by monitoring the Report Soft Error MAC frames generated by stations on each port. Soft errors occur during normal ring operation and do not typically disrupt traffic on the ring. However, soft errors can occur at a rate that could potentially degrade the performance of the ring.
Using the Catalyst 3900 or Catalyst 3920, you can configure soft error thresholds and sampling intervals for a port. During the interval you define, the Catalyst 3900 monitors the stations on the port and if the threshold is exceeded, the switch can be configured to generate a trap indicating the port number and station on which the threshold was exceeded. If necessary, you can issue a Remove Ring Station MAC frame to remove the station from the ring.
In summary, the Catalyst 3900 switch:
In addition to TokenChannels configurations, with Release 4.1(1) of the Catalyst 3900 you can configure ISL Channels.
An ISL Channel is two to four parallel connections treated as a single interface. ISL Channels provide Fast EtherChannel connectivity on the Catalyst 3900. You can configure an ISL Channel between two Catalyst 3900 switches or between a Catalyst 3900 switch and a Catalyst 5000, a Token Ring ISL-capable Cisco router, or a Token Ring ISL network adapter. All connections in an ISL Channel must be FDX.
The Catalyst 3900 ISL Channels provide the following benefits:
With Release 4.1(1), all channel configurations (TokenChannel and ISL Channel) are fault-tolerant.
The fault-tolerant feature enables TokenChannel and ISL Channel configurations to function as long as there is at least one port active in the channel. This capability ensures that large portions of a network are not disrupted in the event a port or cable fails within the channel by transferring the traffic to one or more of the remaining ports in the channel.
A channel displays in a a reduced state on the Current Channel Information Panel when some, but not all of the ports assigned to the channel are up.
With Release 4.1(1), by default STP is enabled on all preferred VLANs. This default applies to those VLANs that are created after the Catalyst 3900 series switch is running software Release 4.1(1) or later. However, you can manually configure the TrBRF STP participation to no, IEEE, IBM and Base on Bridging Mode.
A new STP mode, Base on Bridging Mode, is available at the TrCRF level. Base on Bridging Mode enables the bridging mode of the TrCRF to determine the STP running at the TrCRF. TrCRFs with a bridging mode of SRB run the IEEE STP and TrCRFs with a bridging mode of SRT run the Cisco STP.
The default TrBRF STP is IBM. The default TrCRF STP is Base on Bridging Mode.
This section contains information that was not included in the Catalyst 3900 or Catalyst 3920 User Guides. The headings in this section correspond with the applicable section titles in the documentation.
The following statement that appears in the VTP and VTP Pruning section is misleading:
"VLANs that are not configured to be eligible for pruning are always considered to be in a joining state on every trunk. VLAN 1, the default TrBRF (1005), and TrCRFs are not eligible for pruning."
This statement should read as follows:
"VLANs that are not configured to be eligible for pruning are always considered to be in a joining state on every trunk. VLAN 1, the default TrBRF (1005), and the default TrCRF (1003) are not eligible for pruning. Pruning eligibility is configured on a TrBRF basis. Therefore, if you configure a TrBRF other than the default TrBRF to be pruning eligible, all TrCRFs associated with the TrBRF are pruning eligible as well."
The list of the supported groups of the Token Ring extensions to the Remote Network Monitoring MIB (RFC 1513) is incomplete.
In addition to the MAC-layer statistics group, promiscuous statistics group, Token Ring ring station group, and the Token Ring ring station order group, the following two Token Ring extensions are also supported with Release 4.1(1):
The following Autobaud upon Break parameter description is incorrect:
"Indicates whether the baud rate is reset when a Break key sequence (pressing Enter rapidly for five seconds) is sent or received."
Regardless of the Autobaud upon Break parameter setting, the baud rate is reset when a break sequence is sent or received. The correct description for the Autobaud upon Break parameter is as follows:
"Indicates whether the baud rate is reset after disconnecting and reconnecting the serial cable."
Also, the values 1200 and Autobaud are incorrectly documented as valid values for the Console Baud Rate parameter. The correct Console Baud Rate valid values are 2400, 4800, 9600, 38400, and 57600.
An information panel, the VTP Configuration Information panel, has been added that displays how many local VLANs are currently defined and how many preferred VLANs are currently available.
To access the VTP Configuration panel, select Info on the VTP VLAN Configuration panel. The VLAN Configuration Information panel (Figure 1) is displayed.
The following information is displayed on this panel:
With Release 4.1(1), the maximum number of entries in the Trap Receivers list (viewable on the Trap Receivers panel) is 10. If you have more than 10 entries defined before upgrading to Release 4.1(1), the entries beyond the tenth entry are deleted when you upgrade to Release 4.1(1).
When changes are made to the Catalyst 3900 software, the new image is posted to CCO. You can then obtain a copy of the image and download it to your switch.
For service and support for a product purchased from a reseller, contact the reseller. Resellers offer a wide variety of Cisco service and support programs, which are described in the section "Service and Support" in the information packet that shipped with your product.
For service and support for a product purchased directly from Cisco, use CCO.
Cisco Connection Online (CCO) is Cisco Systems' primary, real-time support channel. Maintenance customers and partners can self-register on CCO to obtain additional information and services.
Available 24 hours a day, 7 days a week, CCO provides a wealth of standard and value-added services to Cisco's customers and business partners. CCO services include product information, product documentation, software updates, release notes, technical tips, the Bug Navigator, configuration notes, brochures, descriptions of service offerings, and download access to public and authorized files.
CCO serves a wide variety of users through two interfaces that are updated and enhanced simultaneously: a character-based version and a multimedia version that resides on the World Wide Web (WWW). The character-based CCO supports Zmodem, Kermit, Xmodem, FTP, and Internet e-mail, and it is excellent for quick access to information over lower bandwidths. The WWW version of CCO provides richly formatted documents with photographs, figures, graphics, and video, as well as hyperlinks to related information.
You can access CCO in the following ways:
For a copy of CCO's Frequently Asked Questions (FAQ), contact cco-help@cisco.com. For additional information, contact cco-team@cisco.com.
Documentation for Cisco products is available in three forms: in a CD-ROM package, printed books, and on the World Wide Web. You have the option of subscribing to the CD ROM package through an update service. Or you can order printed documentation at an additional cost. Refer to the information packet included with the router for detailed ordering information. You can also access Cisco documentation on the World Wide Web URL http://www.cisco.com. ALIGN=TOP SRC="o6763_02/o6763_0a.gif">
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Wed Mar 8 10:01:20 PST 2000
Copyright 1989 - 2000©Cisco Systems Inc.