cc/td/doc/product/lan/cat3900
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

Physical Specifications

Physical Specifications

This appendix provides information about the following:

Switch Physical Specifications

This section lists the power requirements, acceptable operating parameters, and physical dimensions for the base Catalyst 3900 Token Ring Switch.

Power Requirements

The Catalyst 3900's auto-ranging power supply operates on line voltage in the range of 90 to 264 VAC (auto-sensing) and 47 to 63 Hz, 150 Watts maximum. An appropriate power cord for the country of installation is shipped with the Catalyst 3900.

Operating Environment

Table D-1 lists the operating parameters for a Catalyst 3900.


Table  D-1: Catalyst 3900 Operating Parameters
Characteristic Value or Range
Operating temperature 50°F to 104°F (10°C to 40°C)
Operating relative humidity 8% to 80%
Maximum wet-bulb temperature 81°F (27°C)
Thermal dissipation 150 watts (maximum); 512 Btu/hr
Electrical power 1.5 A at 115V; 0.75 A at 230V
Leakage/starting Current less than 3.5 mA/15 amperes/half cycle

Physical Dimensions

Table D-2 lists the physical dimensions of a Catalyst 3900.


Table  D-2: Catalyst 3900 Physical Dimensions
Physical Feature Dimension
Rack mounted width 19 in. (482.6 mm)
Standalone width 17.38 in. (441.45 mm)
Depth 15.25 in. (387.35 mm)
Height 3.4 in. (86.36 mm)
Weight 16 lbs (7.26 kg)

Note Rack mount brackets and mounting hardware are included with the unit.

Stack Port Module Physical Specifications

Table D-3 lists the power requirements of the stack port module.


Table  D-3: Stack Port Module Power Requirements
Electrical power 8 watts maximum (at 5V DC Æ5%)

Table D-4 lists the operating parameters for the stack port module.


Table  D-4: Stack Port Operating Parameters
Temperature 50× F to 104× F (10× C to 40× C)
Relative humidity 8% to 80%
Maximum wet-bulb temperature 81× F (27× C)
Calorific value 27 Btu/hr (7 kcal/hr)

Table D-5 lists the physical dimensions of the stack port module.


Table  D-5: Stack Port Module Physical Dimensions
Width 170 mm (6.7 in.)
Depth 214 mm (8.4 in.)
Height 25 mm (1 in.)

Fiber Token Ring Module Physical Specifications

Table D-6 lists the power requirements of the fiber module.


Table  D-6: Fiber Module Power Requirements
Electrical power 20 watts

Table D-7 lists the operating parameters for the fiber Token Ring module.


Table  D-7: Fiber Module Operating Parameters
Temperature 50°F to 104°F (10°C to 40°C)
Relative humidity 8% to 80%
Maximum wet-bulb temperature 81°F (27°C)

Table D-8 lists the physical dimensions of the fiber Token Ring module.


Table  D-8: Fiber Module Physical Dimensions
Width 5.45 in. (138.4 mm)
Depth 8.06 in. (204.7 mm)
Height 1 in. (25.4 mm)
Weight 1 lb (.45 kg)

Table D-9 lists the optical power transmit and receive parameters of the fiber Token Ring module.


Table  D-9: Fiber Module Transmit and Receive Parameters
Optical Power Minimum Typical Maximum
Transmit -16.0 dbm (25.1 m)

-14.5 dbm (35.5 m)

-12.0 dbm (63.1 m)

Receive -31.0 dbm (0.8 m)

-11.0 dbm (79.4 m)

UTP/STP Token Ring Module Physical Specifications

Table D-10 lists the power requirements of the UTP/STP module.


Table  D-10: UTP/STP Module Power Requirements
Electrical power 20 watts

Table D-11 lists the operating parameters for the UTP/STP Token Ring module.


Table  D-11: UTP/STP Module Operating Parameters
Temperature 50°F to 104°F (10°C to 40°C)
Relative humidity 8% to 80%
Maximum wet-bulb temperature 81°F (27°C)

Table D-8 lists the physical dimensions of the UTP/STP Token Ring module.


Table  D-12: UTP/STP Module Physical Dimensions
Width 5.45 in. (138.4 mm)
Depth 8.06 in. (204.7 mm)
Height 1 in. (25.4 mm)
Weight 1 lb (.45 kg)

ATM Module Physical Specifications

Table D-13 lists the power requirements of the ATM module.


Table  D-13: ATM Module Power Requirements
Electrical power 5 amps at 5 volts DC or 25 watts

Table D-14 lists the operating parameters for the ATM module.


Table  D-14: ATM Module Operating Parameters
Temperature 50× F to 104× F (10× C to 40× C)
Relative humidity 8% to 80%
Maximum wet-bulb temperature 81× F (27× C)

Table D-15 lists the physical dimensions of the ATM module.


Table  D-15: ATM Module Physical Dimensions
Width 6.7 in. (170 mm.)
Depth 8.4 in. (214 mm)
Height 1 in. (25 mm.)

ISL Module Physical Specifications

Table D-16 lists the power requirements of the ISL module.


Table  D-16: ISL Module Power Requirements

Power consumption

20watts

Thermal dissipation 68 BTU/hr

Table D-17 describes the operating environment for the ISL module.


Table  D-17: Operational Parameters
Temperature 50°F to 104°F (10°C to 40°C)
Relative humidity 8% to 80%
Maximum wet-bulb temperature 81°F (27°C)

Table D-18 lists the physical dimensions of the ISL module.


Table  D-18: Physical Dimensions
Width 5.45 in. (138.4 mm)
Depth 8.06 in. (204.7 mm)
Height 1 in. (25.4 mm)
Weight 1 lb (.45 kg)

Table D-19 lists the electromagnetic interference (EMI) standards with which the ISL module complies.


Table  D-19: EMI Standards

STP

FCC Class A (47 CFR, Part 15), ICES-003 Class A, EN 55022 Class A, CISPR22 Class A, AS/NZS 3548 Class A, and VCCI Class A

UTP EN 55022 Class B; CISPR22 Class B, AS/NZS 3590 Class B, and VCCI Class B
Fiber EN 55022 Class B; CISPR22 Class B, AS/NZS 3590 Class B, and VCCI Class B

Note The use of unshielded cables may cause undesired interference in situations where Class B emissions are required.

hometocprevnextglossaryfeedbacksearchhelp
Copyright 1989-1998 © Cisco Systems Inc.