Specifications

Specifications

This appendix provides cable and technical specifications for the Catalyst 2948G and 2980G switches.

Console Port

The console port is an RJ-45 receptacle. Data terminal ready (DTR) and data set ready (DSR) handshake signals are supported on this port. The Request To Send (RTS) signal tracks the state of the Clear To Send (CTS) input. Table A-1 lists the console port pinouts.


Table A-1: Console Port Pinouts
Pin Signal Direction Description

1

RTS

output

request to send

2

DTR

output

data terminal ready

3

TXD

output

Transmit data

4

GND

5

GND

6

RXD

input

receive data

7

DSR

input

data set ready

8

CTS

input

clear to send

10BaseT Management Port

The 10BaseT management port is an RJ-45 receptacle with a Link Status LED. Table A-2 lists the 10BaseT port pinouts.


Table A-2: 10BaseT Port Pinouts
Pin Signal Direction Description

1

RXD+

input

receive data

2

RXD-

input

receive data

3

TXD+

output

transmit data

4

unused

5

unused

6

TXD-

output

transmit data

7

unused

8

unused

Catalyst 2948G Switch Specifications

Table A-3 lists the Catalyst 2948G switch specifications.


Table A-3: Catalyst 2948G Switch Specifications
Item Specification
Environmental

Temperature, ambient operating

32°F (0°C) to 104°F (40°C)

Temperature, ambient nonoperating and storage

-40 to 167°F (-40 to 75°C)

Humidity (RH), ambient (noncondensing) operating

10% to 90%

Environmental (continued)

Humidity (RH), ambient (noncondensing) nonoperating and storage

5% to 95%

Altitude
operating and nonoperating

-60 to 4,000 m

Switching Components

Backplane

12 Gbps full duplex

Microprocessor

150-MHz R5000 RISC-Y2K Compliant

Memory

64 MB SDRAM, 12 MB Flash (onboard), 512 KB NVRAM, 8 MB synchronous SRAM, 256 bytes serial EEROM

Physical Characteristics

Dimensions (H x W x D)

2.625 x 17.5 x 15 in. (6.6 x 44 x 38 cm)

Weight

13 lb (5.9 kg)

AC Power

Power supply output

120W

System power dissipation

189W

System heat dissipation

645 BTU/hr.

AC-input

2.5A maximum @ 100 VAC
1.3A maximum @ 240VAC

AC frequency

50 to 60 Hz

KVA rating

0.20 KVA

Airflow

Right side in, left side out

Standards Compliance

Compliance

CE Marking

Safety

UL1 1950, CSA2-C22.2 No. 950, EN360950, IEC4 950, TS5 001, AS/NZS6 3260

EMI7

FCC8 Class A (CFR9 47, part 15), ICES10-003 Class A, EN55022 Class A, CISPR22 Class A, AS/NZS 3548 Class A, and VCCI11 Class A with FTP12 cables


EN55022 Class B, CISPR22 Class B, AS/NZS 3548 Class B, and VCCI Class B with FTP cables

1UL = Underwriters Laboratory.
2CSA = Canadian Standards Association.
3EN = European Norm.
4IEC = International Electrotechnical Commission.
5TS = Technical Standard.
6AS/NZS = Australian/New Zealand Standard.
7EMI = electromagnetic interference.
8FCC = Federal Communications Commission.
9CFR = Code of Federal Regulations.
10ICES = International Commerce Exchange Systems.
11VCCI = Voluntary Control Council for Information Technology Equipment.
12FTP = foil twisted-pair.

Catalyst 2980G Switch Specifications

Table A-4 lists the Catalyst 2980G switch specifications.


Table A-4: Catalyst 2980G Switch Specifications
Item Specification
Environmental

Temperature, ambient operating

32°F (0°C) to 104°F (40°C)

Temperature,ambient nonoperating and storage

-4 to 149°F (-20 to 65°C)

Humidity (RH), ambient (noncondensing) operating

10% to 90%

Humidity (RH), ambient (noncondensing) nonoperating and storage

5% to 95%

Altitude, operating and nonoperating

-60 to 4,000 m

Switching Components

Backplane

12 Gbps full duplex

Microprocessor

150-MHz R5000 RISC-Y2K compliant

Memory

64 MB SDRAM, 16 MB Flash (onboard), 512 KB NVRAM, 8 MB synchronous SRAM, 256 bytes serial EEROM

Physical Characteristics

Dimensions (H x W x D)

3.38 x 17.17 x 14.3 in. (8.6 x 43.6 x 36.3 cm)

Weight

13 lb (5.9 kg)

AC Power

Power supply output

175W

System power dissipation

270W

System heat dissipation

950 BTU/hr.

AC-input

3.0A maximum @ 100 VAC
1.5A maximum @ 240VAC

AC Power (continued)

AC frequency

50 to 60 Hz

KVA rating

0.30 KVA

Airflow

Right side in, left side out

Standards Compliance

Compliance

CE Marking

Safety

UL1 1950, CSA2-C22.2 No. 950, EN360950, IEC4 950

EMI5

FCC6 Class A (CFR7 47, part 15), ICES8-003 Class A, EN55022 Class A, CISPR22 Class A, AS/NZS 3548 Class A, and VCCI9 Class A with FTP10 cables


EN55022 Class B, CISPR22 Class B, AS/NZS 3548 Class B, and VCCI Class B with FTP cables

1UL = Underwriters Laboratories.
2CSA = Canadian Standards Association.
3EN = European Norm.
4IEC = International Electrotechnical Commission.
5EMI = electromagnetic interference.
6FCC = Federal Communications Commission.
7CFR = Code of Federal Regulations.
8ICES = International Commerce Exchange Systems.
9VCCI = Voluntary Control Council for Information Technology Equipment.
10FTP = foil twisted-pair.


hometocprevnextglossaryfeedbacksearchhelp
Posted: Fri Mar 31 10:28:20 PST 2000
Copyright 1989 - 2000©Cisco Systems Inc.