This appendix provides cable and technical specifications for the Catalyst 2948G and 2980G switches.
The console port is an RJ-45 receptacle. Data terminal ready (DTR) and data set ready (DSR) handshake signals are supported on this port. The Request To Send (RTS) signal tracks the state of the Clear To Send (CTS) input. Table A-1 lists the console port pinouts.
| Pin | Signal | Direction | Description |
|---|---|---|---|
1 | RTS | output | request to send |
2 | DTR | output | data terminal ready |
3 | TXD | output | Transmit data |
4 | GND |
|
|
5 | GND |
|
|
6 | RXD | input | receive data |
7 | DSR | input | data set ready |
8 | CTS | input | clear to send |
The 10BaseT management port is an RJ-45 receptacle with a Link Status LED. Table A-2 lists the 10BaseT port pinouts.
| Pin | Signal | Direction | Description |
|---|---|---|---|
1 | RXD+ | input | receive data |
2 | RXD- | input | receive data |
3 | TXD+ | output | transmit data |
4 | unused |
|
|
5 | unused |
|
|
6 | TXD- | output | transmit data |
7 | unused |
|
|
8 | unused |
|
|
Table A-3 lists the Catalyst 2948G switch specifications.
| Item | Specification | |
|---|---|---|
| Environmental |
| |
Temperature, ambient operating | 32°F (0°C) to 104°F (40°C) | |
Temperature, ambient nonoperating and storage | -40 to 167°F (-40 to 75°C) | |
Humidity (RH), ambient (noncondensing) operating | 10% to 90% | |
| Environmental (continued) | ||
Humidity (RH), ambient (noncondensing) nonoperating and storage | 5% to 95% | |
Altitude | -60 to 4,000 m | |
| Switching Components | ||
Backplane | 12 Gbps full duplex | |
150-MHz R5000 RISC-Y2K Compliant | ||
64 MB SDRAM, 12 MB Flash (onboard), 512 KB NVRAM, 8 MB synchronous SRAM, 256 bytes serial EEROM | ||
| Physical Characteristics | ||
2.625 x 17.5 x 15 in. (6.6 x 44 x 38 cm) | ||
13 lb (5.9 kg) | ||
| AC Power | ||
Power supply output | 120W | |
189W | ||
645 BTU/hr. | ||
AC-input | 2.5A maximum @ 100 VAC | |
50 to 60 Hz | ||
KVA rating | 0.20 KVA | |
Airflow | Right side in, left side out | |
| Standards Compliance |
| |
Compliance | CE Marking | |
Safety | UL1 1950, CSA2-C22.2 No. 950, EN360950, IEC4 950, TS5 001, AS/NZS6 3260 | |
EMI7 | FCC8 Class A (CFR9 47, part 15), ICES10-003 Class A, EN55022 Class A, CISPR22 Class A, AS/NZS 3548 Class A, and VCCI11 Class A with FTP12 cables | |
Table A-4 lists the Catalyst 2980G switch specifications.
| Item | Specification | |
|---|---|---|
| Environmental |
|
|
Temperature, ambient operating | 32°F (0°C) to 104°F (40°C) | |
Temperature,ambient nonoperating and storage | -4 to 149°F (-20 to 65°C) | |
Humidity (RH), ambient (noncondensing) operating | 10% to 90% | |
Humidity (RH), ambient (noncondensing) nonoperating and storage | 5% to 95% | |
Altitude, operating and nonoperating | -60 to 4,000 m | |
| Switching Components | ||
Backplane | 12 Gbps full duplex | |
150-MHz R5000 RISC-Y2K compliant | ||
64 MB SDRAM, 16 MB Flash (onboard), 512 KB NVRAM, 8 MB synchronous SRAM, 256 bytes serial EEROM | ||
| Physical Characteristics | ||
3.38 x 17.17 x 14.3 in. (8.6 x 43.6 x 36.3 cm) | ||
13 lb (5.9 kg) | ||
| AC Power | ||
Power supply output | 175W | |
270W | ||
950 BTU/hr. |
| |
AC-input | 3.0A maximum @ 100 VAC | |
| AC Power (continued) | ||
50 to 60 Hz | ||
KVA rating | 0.30 KVA | |
Airflow | Right side in, left side out | |
| Standards Compliance |
|
|
Compliance | CE Marking | |
Safety | ||
EMI5 | FCC6 Class A (CFR7 47, part 15), ICES8-003 Class A, EN55022 Class A, CISPR22 Class A, AS/NZS 3548 Class A, and VCCI9 Class A with FTP10 cables | |
![]()
![]()
![]()
![]()
![]()
![]()
![]()