This appendix lists the technical specifications and regulatory agency approvals for the Catalyst 2900 series modules.

Environmental Ranges

Operating temperature

10BaseT, 100BaseTX, 100BaseFX, 1000BaseX modules

32 to 122ºF (0 to 50ºC)

1000BaseT module

-23 to 113ºF (-5 to 45ºC)

Storage temperature

10BaseT, 100BaseTX, 100BaseFX, 1000BaseX modules

-4 to 149ºF (-20 to 65ºC)

1000BaseT module

-13 to 158ºF (-25 to 70ºC)

Operating humidity

10BaseT, 100BaseTX, 100BaseFX, 1000BaseX modules

10 to 85% (noncondensing)

1000BaseT module

10 to 90% (noncondensing)

Storage humidity

10BaseT, 100BaseTX, 100BaseFX, 1000BaseX modules

5 to 95% (noncondensing)

1000BaseT module

5 to 95% (noncondensing)

Operating altitude

10BaseT, 100BaseTX, 100BaseFX, 1000BaseX modules

Up to 10,000 ft (3048 m)

1000BaseT module

Up to 10,000 ft (3048 m)

Storage altitude

10BaseT, 100BaseTX, 100BaseFX, 1000BaseX modules

Up to 15,000 ft (4570 m)

1000BaseT module

Up to 30,000 ft (9114 m)

Power Consumption

Module Type Current

10/100

6.60W

100BaseFX

8.40W (two ports)
11.85W (four ports)

1000BaseX

11.2W

1000BaseT

15.5W

Physical Dimensions

Height x Width x Depth

1.25 x 5.75 x 10.3 in.
(3.18 x 14.61 x 26.16 cm)

Weight

10.1 oz (0.29 kg)

Agency Approvals

Safety EMI

AS/NZS 3260, TS001

FCC Part 15 Class A

UL 1950/CSA 22.2 No. 950

EN 55022A Class A (CISPR 22 Class A)

IEC 950/EN 60950

VCCI Class A

CE

AS/NRZ 3548 Class A

BCIQ

CE Class A


hometocprevnextglossaryfeedbacksearchhelp