This appendix describes the cables and connectors for the Catalyst 2900 series modules.
The 10/100 module ports are marked with an X, indicating that they have their transmit (TD) and receive (RD) signals internally crossed for attachment of an Ethernet adapter using a straight-through cable.
When connecting the 10/100 ports to 10BaseT or 100BaseTX servers and workstations, ensure that you use a Category 5 straight-through cable. When connecting to other switches or repeaters, ensure that you use a crossover cable.
The schematics of crossover and straight-through cables are shown in Figure B-1.

![]() |
Note Always observe the following general rules when connecting devices: use a straight-through cable to connect two ports when one is designated with an X; use a crossover cable to connect two ports when both are designated with an X. |
The 1000BaseT module has one or more RJ-45 connectors on the front panel. Figure B-2 shows the pinout.

The 1000BaseT module has one RJ-45 connector on the front panel. Figure B-3 shows the pinout.

The 100BaseFX and the 1000BaseX modules use duplex SC connectors. This type of connector is shown in Figure B-4.

![]()
![]()
![]()
![]()
![]()
![]()
![]()