December 30, 1998
These release notes describe the caveats for the Catalyst 2900 series XL modules.
These release notes contain the following topics:
The Catalyst 2900 series XL modules can add port density and fiber-optic connectivity to a Catalyst 2900 series XL network. When installed in a Catalyst 2912MF XL, Catalyst 2916M XL, or Catalyst 2924M XL switch, these modules support switched 10BaseT, 100BaseTX, or 100BaseFX connections. The 10BaseT/100BaseTX module autonegotiates the duplex and speed settings of each port to match that of the attached device.
Enhancements to the previous Catalyst 2900 series XL modules include:
You must tighten the screws while inserting the module in the switch.
Warning 
Tighten screws to activate.
Waarschuwing Schroeven aandraaien om te activeren.
Varoitus Aktivoi kiristämällä ruuvit.
Attention Pour activer : serrez les vis.
Warnung Schrauben anziehen für Aktivierung.
Avvertenza Per attivare: stringere la vite.
Advarsel Stram skruene for å aktivere.
Aviso Aperte os parafusos para ativar.
¡Advertencia! Para activar, apriete los tornillos.
Varning! Aktivera genom att dra åt skruvarna
.
To use the new Catalyst 2900 series XL modules (WS-X2914-XL-V, WS-X2922-XL-V, and WS-X2924-XL-V) with a Catalyst 2916M XL series switch (WS-C2916M-XL), you must upgrade the switch software.
The multi-VLAN and 802.1Q trunking features are not available in this release. These features will be available in a future release of the Catalyst 2900 XL switch firmware.
You can install Catalyst 2900 series XL modules while the switch is running if you are running Cisco IOS Release 11.2(8)SA3 (September 1998) or later. If you are running a previous release of the Cisco IOS, power down the switch before installing the modules.
This section describes the procedure for upgrading your Catalyst 2916M XL series switch software by using the Cisco IOS command-line interface (CLI). To perform the steps in this section, you must have a TFTP server and a management station (such as a PC) with a CD-ROM drive. You must also access the switch management console by either of these two methods:
Follow these steps to download a new version of Catalyst 2900 software:
Step 1 Insert the CD-ROM into the CD-ROM drive.
Step 2 Copy the following files from the CD-ROM to a location on your TFTP-enabled PC (or transfer the files to the switch directly from the CD-ROM):
You can use the CLI to perform a TFTP transfer of the files to the switch.
The procedure that follows includes the commands to address the following issues:
Follow these steps to upgrade the switch software by using a TFTP transfer:
Step 1 If your PC or workstation cannot act as a TFTP server, copy the files to a TFTP server to which you have access.
Step 2 You can access the CLI by starting a Telnet session or by connecting to the console port via the RS-232 connector.
To start a Telnet session on your PC or workstation, enter the following command:
server% telnet switch_ip_address
Step 3 Enter privileged EXEC mode:
switch> enable
switch#
Step 4 Display the name of the current (default) image file. The following example shows the current name in italic:
switch# show boot
BOOT path-list: flash:current_image
Config file: flash:config.text
Enable Break: 1
Manual Boot: no
Step 5 If there is no file defined in the BOOT path-list, enter dir flash: to display the contents of Flash memory. The file named c2900XL-h-mz_current_version is your current image file.
Step 6 Rename the current image file to the name of the new image. This does not affect the operation of the switch.
switch# rename flash:current_image flash:new_image
Source filename [current_image]?
Destination filename [new_image]?
Step 7 Display the contents of Flash memory to verify the renaming of the file:
switch# dir flash:
Directory of flash:
-rwx 910426 Mar 06 1993 23:47:28 new_image -rwx 80971 Sep 14 1998 03:10:38 c2900XL-diag-mz-112.0.0.11-SA2
-rwx 4800 Mar 01 1993 00:04:14 html
-rwx 159 Jan 01 1970 00:00:34 env_vars
-rwx 1121 Mar 01 1993 18:46:01 config.text
Step 8 Delete the diagnostics file to make room for the new image.
The diagnostics file has a name in the following format: c2900XL-diag-mz-version_name. The string version_name depends on the switch and software you are running.
Display the diagnostics file:
switch# dir flash:c2900XL-diag-mz*
Directory of flash:
-rwx 80971 Sep 14 1998 03:10:38 c2900XL-diag-mz-112.0.0.11-SA2
Delete the diagnostics file:
Switch# del flash:c2900XL-diag-mz-112.0.0.11-SA2 Delete filename [c2900XL-diag-mz-112.0.0.11-SA2]? Delete flash:c2900XL-diag-mz-112.0.0.11-SA2? [confirm] Switch#
Step 9 Enter terminal configuration mode:
switch# configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Step 10 Disable access to the switch HTML pages:
switch(config)# no IP http server
Step 11 Change the name of the default image file:
switch(config)# boot system flash:new_image
Step 12 Return to privileged EXEC mode:
switch(config)# end
Step 13 Verify that the name of the default image file is correct:
switch# show boot
BOOT path-list: flash:new_image
Config file: flash:config.text
Enable Break: 1
Manual Boot: no
HELPER path-list:
NVRAM/Config file
buffer size: 32768
Step 14 Use the name of the new image file when you copy it from the TFTP server to the Flash memory:
switch# copy tftp://server_ip_address//path/new_image flash:new_image
Source IP address or hostname [server_ip_address]?
Source filename [path/filename]?
Destination filename [flash:new_image]?
Loading /path/filename.bin from server_ip_address (via!)
[OK - 843975 bytes]
Step 15 Remove the manager software HTML files:
switch# del flash:html/*.*
Press the Enter key to confirm the deletion of each file. Do not press any other keys during this process.
Step 16 If you are running Cisco IOS Release 11.2(8)SA3 or later, remove the files in the Snmp directory:
switch# del flash:html/Snmp/*.*
Press the Enter key to confirm the deletion of each file. Do not press any other keys during this process.
Step 17 If you are running Cisco IOS Release 11.2(8)SA2 or earlier, create a directory on the switch Flash memory to be used for the HTML files:
switch# mkdir flash:html/Snmp
Make sure the "S" in "Snmp" is uppercase.
Step 18 Enter the following command to copy the HTML file from the TFTP server to the switch Flash memory:
switch# tar /x tftp://server_ip_address//path/filename.tar flash:html Loading /path/filename.tar from server_ip_address (via!)
extracting advanced.gif (2648 bytes)
extracting amber.gif (530 bytes)!
extracting bar.gif (4156 bytes)!
extracting cool.gif (530 bytes)
extracting daytona.gif (1470 bytes)
extracting duplgnd.gif (639 bytes)!
. . .
Depending on the TFTP server being used, you might need to enter only one slash (/) after the server_ip_address in the tar command.
Step 19 Enter terminal configuration mode:
switch(config)# configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Step 20 Reenable access to the switch HTTP pages:
switch(config)# IP http server
Step 21 Return to privileged EXEC mode:
switch(config)# end
Step 22 Reload the new software with the following command:
switch# reload
System configuration has been modified. Save? [yes/no]:y
Proceed with reload? [confirm]
Step 23 Press Return to confirm the reload.
Your Telnet session ends when the switch resets.
For a list of Catalyst 2900 software caveats, refer to the Release Notes for the Catalyst 2900 Series XL Cisco IOS Release 11.2(8)SA4.
The product documentation for the Catalyst 2900 series XL modules and the Catalyst 2900 series XL switches is as follows:
Cisco Connection Online (CCO) is Cisco Systems' primary, real-time support channel. Maintenance customers and partners can self-register on CCO to obtain additional information and services.
Available 24 hours a day, 7 days a week, CCO provides a wealth of standard and value-added services to Cisco's customers and business partners. CCO services include product information, product documentation, software updates, release notes, technical tips, the Bug Navigator, configuration notes, brochures, descriptions of service offerings, and download access to public and authorized files.
CCO serves a wide variety of users through two interfaces that are updated and enhanced simultaneously: a character-based version and a multimedia version that resides on the World Wide Web (WWW). The character-based CCO supports Zmodem, Kermit, Xmodem, FTP, and Internet e-mail, and it is excellent for quick access to information over lower bandwidths. The WWW version of CCO provides richly formatted documents with photographs, figures, graphics, and video, as well as hyperlinks to related information.
You can access CCO in the following ways:
For a copy of CCO's Frequently Asked Questions (FAQ), contact cco-help@cisco.com. For additional information, contact cco-team@cisco.com.
Cisco documentation and additional literature are available in a CD-ROM package, which ships with your product. The Documentation CD-ROM, a member of the Cisco Connection Family, is updated monthly. Therefore, it might be more current than printed documentation. To order additional copies of the Documentation CD-ROM, contact your local sales representative or call customer service. The CD-ROM package is available as a single package or as an annual subscription. You can also access Cisco documentation on the World Wide Web at http://www.cisco.com, http://www-china.cisco.com, or http://www-europe.cisco.com.
If you are reading Cisco product documentation on the World Wide Web, you can submit comments electronically. Click Feedback in the toolbar and select Documentation. After you complete the form, click Submit to send it to Cisco. We appreciate your comments.

![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Fri Apr 7 15:57:58 PDT 2000
Copyright 1989 - 2000©Cisco Systems Inc.