Table A-1: Technical Specifications for the Catalyst 2912 XL and Catalyst 2912MF XL

Catalyst 2912 XL Catalyst 2912MF XL

Environmental Operating Ranges

Operating temperature

32 to 122°F (0 to 50°C)

32 to 122°F (0 to 50°C)

Storage temperature

-4 to 149°F (-20 to 65°C)

-4 to 149°F (-20 to 65°C)

Operating humidity

10 to 85% (noncondensing)

10 to 85% (noncondensing)

Operating altitude

Up to 10000 ft (3000 m)

Up to 10000 ft (3000 m)

Power Requirements

AC input voltage

100 to 127/200 to 240 VAC
(autoranging) 50 to 60 Hz

100 to 127/200 to 240 VAC (autoranging) 50 to 60 Hz

DC input voltages

+5V @9A, +12V
@0.5A

+5V @12A, +12V
@0.75A

+5V
@22A, +12V
@0.75A
(with two modules installed)

Power consumption

70W

239 BTU per hour

90W
307 BTU per hour

170W (with two modules installed)
580 BTU per hour

Physical Dimensions

Weight

7 lb (3.2 kg)

17 lb (7.7 kg)

18 lb (8.2 kg with two modules installed)

Dimensions (H x W x D)

1.73 x 17.5 x 9.79 in.
(4.4 x 44.5 x 24.8 cm)

3.46 x 17.5 x 12 in.
(8.8 x 44.5 x 30.5 cm)


Table A-2: Technical Specifications for the Catalyst 2924 XL and Catalyst 2924C XL

Catalyst 2924 XL Catalyst 2924C XL

Environmental Operating Ranges

Operating temperature

32 to 122°F (0 to 50°C)

32 to 122°F (0 to 50°C)

Storage temperature

-4 to 149°F (-20 to 65°C)

-4 to 149°F (-20 to 65°C)

Operating humidity

10 to 85% (noncondensing)

10 to 85% (noncondensing)

Altitude

Up to 10000 ft (3000 m)

Up to 10000 ft (3000 m)

Power Requirements

AC input voltage

100 to 127/200 to 240 VAC
(autoranging) 50 to 60 Hz

100 to 127/200 to 240 VAC
(autoranging) 50 to 60 Hz

DC input voltages

+5V @9A, +12V
@0.5A

+5V @9A, +12V
@0.5A

Power consumption

70W

239 BTU per hour

70W

239 BTU per hour

Physical Dimensions

Weight

7 lb (3.2 kg)

7 lb (3.2 kg)

Dimensions (H x W x D)

1.73 x 17.5 x 9.79 in.
(4.4 x 44.5 x 24.8 cm)

1.73 x 17.5 x 9.79 in.
(4.4 x 44.5 x 24.8 cm)


Table A-3: Technical Specifications for the Catalyst 2924M XL

Catalyst 2924M XL

Environmental Operating Ranges

Operating temperature

32 to 122°F (0 to 50°C)

Storage temperature

-4 to 149°F (-20 to 65°C)

Operating humidity

10 to 85% (noncondensing)

Altitude

Up to 10000 ft (3000 m)

Power Requirements

AC input voltage

100 to 127/200 to 240 VAC
(autoranging) 50 to 60 Hz

DC input voltages

+5V @12A, +12V
@0.55A

+5V
@22A, +12V
@0.75A
(with 2 modules installed)

Power consumption

90W
307 BTU per hour

170W (with two modules installed)
580 BTU per hour

Physical Dimensions

Weight

13.5 lb (6.12 kg)

15 lb (6.80 kg with two modules installed)

Dimensions (H x W x D)

3.46 x 17.5 x 12 in.
(8.8 x 44.5 x 30.5 cm)


Table A-4: Catalyst 2900 Series XL Agency Approvals
Safety EMI

UL 1950/CSA 22.2 No. 950

FCC Part 15 Class A

IEC 950/EN 60950

EN 55022 Class A (CISPR 22 Class A)

AS/NZS 3260, TS001

VCCI Class A

CE

AS/NZS 3548 Class A

BCIQ

CE


hometocprevnextglossaryfeedbacksearchhelp