This booklet explains how to use the following upgrade kits to upgrade software for the Catalyst 2900 series XL and the 3500 series XL switches:
Use the Catalyst 2900 Series XL Enterprise Edition Software upgrade kit (single switch and ten-pack) to make the following changes to switch software:
Table 1 shows the upgrade path. It lists the current image in Flash memory and the directory and filename of the new image on the upgrade CD.
| Current Image in Flash Memory | New Image on Upgrade CD |
|---|---|
Standard edition (A) software: c2900XL-h2-mz.11.2.8-SA6.bin | Enterprise Edition (EN) Software: /c2900XL_Enterprise/c2900XL-h2s-mz-112.8-SA6.tar |
Standard edition command (AC) switch software: c2900XL-c3h2-mz-112.8-SA6.bin | Enterprise Edition Command (ENC) Switch Software: /c2900XL_Enterprise_Command/c2900XL-c3h2s-mz-112.8-SA6.tar |
Use the Catalyst 2900 Series XL Command Switch Software upgrade kit to make the following changes to switch software:
Table 2 shows the upgrade path. It lists the current image in Flash memory and the directory and filename of the new image on the upgrade CD.
| Current Image in Flash Memory | New Image on Upgrade CD |
|---|---|
Standard edition (A) software: c2900XL-h2-mz-112.8-SA6.bin | Standard edition command (AC) switch software: /c2900XL_Standard_Command/c2900XL-c3h2-mz-112.8-SA6.tar |
Enterprise Edition (EN) Software: c2900XL-h2s-mz-112.8-SA6.bin | Enterprise Edition Command (ENC) Switch Software: /c2900XL_Enterprise_Command/c2900XL-c3h2s-mz-112.8-SA6.tar |
Use the Catalyst 3500 Series XL Enterprise Edition Software upgrade kit (single switch and ten-pack) to make the following change to switch software:
Table 3 shows the upgrade path. It lists the current image in Flash memory and the directory and filename of the new image on the upgrade CD.
| Current Image in Flash Memory | New Image on Upgrade CD |
|---|---|
Standard edition (AC) software: c3500XL-c3h2-mz-112.8-SA6.bin | Enterprise Edition Command (ENC) Switch Software: /c3500XL_Enterprise/c3500XL-c3h2s-mz-112.8-SA6.tar |
For additional information about the 2900 XL and 3500 XL switches and the features included in IOS Release 11.2(8) SA6, refer to the following documents:
You install upgrade software by using a TFTP server to download the new image from the upgrade CD to the switch. The procedures that follow explain how to install the Cisco TFTP server and use it to download the software image. The upgrade CD contains the Cisco TFTP server for your convenience.
For these procedures, you must have IP connectivity between the TFTP server and the switch. You must also have a management station (such as a PC) with a CD-ROM drive.
The Cisco TFTP server is located on the CD with the upgrade images. You can use this server on Windows 95, Windows 98, or Windows NT 4.0. To prepare for using the TFTP server, follow these steps:
1. Install the Cisco TFTP server.
Copy the self-extracting executable file to your desktop, click it, and follow the installation instructions.
2. Start the Cisco TFTP server.
Double-click the server icon on the desktop, or from the Start menu, select Programs>Cisco TFTP Server.
3. Disable TFTP server options for group upgrades.
If you purchased the ten-pack upgrade kit and you already have clustering configured on your switches, you can use Cluster Management software to perform a group upgrade from the command switch. However, your TFTP server must be capable of handling multiple requests and sessions at the same time.
The Cisco TFTP server application can handle multiple requests and sessions, but you must first disable the Show File Transfer Progress and the Enable Logging options to avoid TFTP server failures.
To disable these options, select View>Options from the Cisco TFTP server menu bar to display the Options window. Then deselect these options and click OK.
4. Create a root directory on the TFTP server to store the upgrade image.
From the TFTP server menu bar, select View>Options. In the TFTP Server Root Directory field, click Browse. The Browse for TFTP Server Root Directory window appears. Select a root directory, and click OK. When the Options window appears, click OK.
Click Help on the menu bar if you need more information.
Use this procedure with the Catalyst 2900 Series XL Enterprise Edition Software upgrade kit or the Catalyst 2900 Series XL Command Switch Software upgrade kit. The procedure adds the features described on or on to 2900 XL switches with 8 MB of DRAM.
The upgrade procedure comprises four general steps:
If you purchased the ten-pack upgrade kit and you already have clustering configured on your switches, you can use the Cluster Management software to perform a group upgrade from the command switch. For more information, click Help in Cluster Manager.
Follow these steps to upgrade the 2900 XL switch image:
1. Insert the Enterprise Edition or Command Switch software CD into the CD-ROM drive of the management station.
2. Copy the image file (tar file) to the root directory of the TFTP server.
See Table 1 on and Table 2 on for the name of the image file for the upgrade that you want to perform.
For instructions on how to define the root directory of the TFTP server, see the "Installing the Cisco TFTP Server" section.
3. Power up the switch and wait for the power-on self-test (POST) to execute.
For information about POST, see the Catalyst 2900 Series XL Installation Guide.
4. Access the switch CLI.
If an IP address is assigned to the switch and the switch is configured for Telnet (for configuration instructions, see the Cisco IOS Desktop Switching Software Configuration Guide), start a Telnet session to access the CLI.
To start the session on your PC or workstation, enter the following command:
server% telnet switch_ip_address
Enter the password if prompted to do so.
If the switch is not configured for Telnet, connect to the console port using the RS-232 connector. For more information, see the Catalyst 2900 Series XL Installation Guide.
5. At the command prompt, enter privileged EXEC mode:
switch> enable
Password:
switch#
6. Confirm that the switch has 8 MB of DRAM.
In the following example, DRAM size (shown in bold) is 8192K.
switch# show version Copyright (c) 1986-1999 by cisco Systems, Inc. Compiled Wed 07-Apr-99 11:46 by jbadmin Image text-base: 0x00003000, data-base: 0x00258164 ROM: Bootstrap program is C2900XL boot loader Switch202 uptime is 19 hours, 23 minutes System restarted by power-on System image file is "flash:boot", booted via - cisco WS-C2912-XL (PowerPC403GA) processor (revision 0x11) with 8192K/1024K bytes of memory.
7. Display the name of the image file that the switch is using.
The following example shows the location (in italics) of the image filename:
switch# show boot
BOOT path-list: flash:current_image
Config file: flash:config.text
Enable Break: 1 Manual Boot: no Helper path-list: NVRAM/Config file buffer size: 32748
If no file is defined in the BOOT path-list, enter dir flash: to display the contents of Flash memory. The displayed filename looks similar to this: c2900XL-h-mz_current_version.
8. Rename the current image file.
Renaming the current image does not affect the operation of the switch.
Use the name of the tar file that you copied in Step 2 to rename the current image. See Table 1 on and Table 2 on for the filename of the specific upgrade you want to perform.
switch# rename flash:current_image flash:new_image.bin
Source filename [current_image]?
Destination filename [new_image]?
9. Display the contents of Flash memory to verify the renaming of the file:
switch# dir flash:
Directory of flash:
-rwx 910426 Mar 06 1993 23:47:28 new_image.bin -rwx 80971 Sep 14 1998 03:10:38 c2900XL-diag-mz-112.0.0.11-SA4
-rwx 4800 Mar 01 1993 00:04:14 html
-rwx 159 Jan 01 1970 00:00:34 env_vars
-rwx 1121 Mar 01 1993 18:46:01 config.text
10. Enter global configuration mode:
switch# configure terminal
Enter configuration commands, one per line. End with CNTL/Z. switch(config)#
11. Disable access to the switch HTML pages to prevent users from accessing CVSM pages during the upgrade.
switch(config)# no IP http server
12. Set the boot path to the new image, if needed.
If you previously entered the BOOT path-list command to specify an image filename to the boot loader, enter this command to change the current boot filename to the new name.
switch(config)# boot system flash:new_image.bin
13. Exit global configuration mode:
switch(config)# end
switch#
14. Remove the CVSM HTML files:
switch# delete flash:html/*
Press Enter to confirm the deletion of each file. Do not press any other keys during this process.
15. Remove the files in the Snmp directory:
switch# delete flash:html/Snmp/*
Press Enter to confirm the deletion of each file. Do not press any other keys during this process.
16. Copy the image from the TFTP server to the switch Flash memory:
switch# tar /x tftp://server_ip_address//path/filename.tar flash:
Loading /path/filename.tar from server_ip_address (via VLAN1):!)
extracting info (110 bytes) extracting c2900XL-c3h2s-mz-112.8-SA6.bin (1271095 bytes)!!!!!!!!!!!!!!!!!!!! html/ (directory) extracting html/Detective.html.gz (1134 bytes)! extracting html/ieGraph.html.gz (553 bytes) extracting html/DrawGraph.html.gz (760 bytes)! . . .
17. Enter global configuration mode:
switch# configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
switch(config)#
18. Re-enable access to the switch HTTP pages:
switch(config)# IP http server
19. Exit global configuration mode:
switch(config)# end switch#
20. Reload the new image:
switch# reload
System configuration has been modified. Save? [yes/no]:y
Proceed with reload? [confirm]
21. Press Return to confirm the reload.
Your Telnet session ends when the switch resets.
Use this procedure with the Catalyst 3500 Series XL Enterprise Edition Software upgrade kit. The procedure upgrades 3500 XL switches from standard edition software to Enterprise Edition Software.
The upgrade procedure comprises four general steps:
If you purchased the ten-pack upgrade kit and you already have clustering configured on your switches, you can use the Cluster Management software to perform a group upgrade from the command switch. For more information, click Help in Cluster Manager.
Follow these steps to upgrade the 3500 XL switch image:
1. Insert the Enterprise Edition Software CD into the CD-ROM drive of the management station.
2. Copy the image file (tar file) to the root directory of the TFTP server.
See Table 3 on for the name of the image file for the upgrade that you want to perform.
For instructions on how to define the root directory of the TFTP server, see the "Installing the Cisco TFTP Server" section.
3. Power up the switch and wait for it to execute the power-on self-test (POST).
For information about POST, see the Catalyst 3500 Series XL Installation Guide.
4. Access the switch CLI.
If an IP address is assigned to the switch and the switch is configured for Telnet (for configuration instructions, see the Cisco IOS Desktop Switching Software Configuration Guide), start a Telnet session to access the CLI.
To start the session on your PC or workstation, enter the following command:
server% telnet switch_ip_address
Enter the password if prompted to do so.
If the switch is not configured for Telnet, connect to the console port using the RS-232 connector. For more information, see the Catalyst 3500 Series XL Installation Guide.
5. At the command prompt, enter privileged EXEC mode:
switch> enable
Password:
switch#
6. Display the name of the image file that the switch is using.
The following example shows the location (in italics) of the image filename:
switch# show version
BOOT path-list: flash:current_image
Config file: flash:config.text
Enable Break: 1 Manual Boot: no Helper path-list: NVRAM/Config file buffer size: 32748
If no file is defined in the BOOT path-list, enter dir flash: to display the contents of Flash memory. The displayed filename looks similar to this: c3500XL-c3h2-mz_current_version.
7. Rename the current image file.
Renaming the current image does not affect the operation of the switch.
See Table 3 on for the filename of the specific upgrade you want to perform.
switch# rename flash:current_image flash:new_image.bin
Source filename [current_image]?
Destination filename [new_image]?
8. Display the contents of Flash memory to verify the renaming of the file:
switch# dir flash:
Directory of flash:
-rwx 910426 Mar 06 1993 23:47:28 new_image.bin -rwx 80971 Sep 14 1998 03:10:38 c3500XL-diag-mz-112.0.0.11-SA6
-rwx 4800 Mar 01 1993 00:04:14 html
-rwx 159 Jan 01 1970 00:00:34 env_vars
-rwx 1121 Mar 01 1993 18:46:01 config.text
9. Enter global configuration mode:
switch# configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
switch(config)#
10. Disable access to the switch HTML pages to prevent users from accessing CVSM pages during the upgrade.
switch(config)# no IP http server
11. Set the boot path to the new image, if needed.
If you previously entered the BOOT path-list command to specify the image filename to the boot loader, enter this command to change it to the new name.
switch(config)# boot system flash:new_image.bin
12. Exit global configuration mode:
switch(config)# end
switch#
13. Remove the CVSM HTML files:
switch# delete flash:html/*
Press Enter to confirm the deletion of each file. Do not press any other keys during this process.
14. Remove the files in the Snmp directory:
switch# delete flash:html/Snmp/*
Press Enter to confirm the deletion of each file. Do not press any other keys during this process.
15. Copy the image from the TFTP server to the switch Flash memory:
switch# tar /x tftp://server_ip_address//path/filename.tar flash:
Loading /path/filename.tar from server_ip_address (via VLAN1):!)
extracting info (110 bytes) extracting c3500XL-c3h2s-mz-112.8-SA6.bin (1271095 bytes)!!!!!!!!!!!!!!!!!!!! html/ (directory) extracting html/Detective.html.gz (1134 bytes)! extracting html/ieGraph.html.gz (553 bytes) extracting html/DrawGraph.html.gz (760 bytes) extracting html/GraphFrame.html.gz (774 bytes)! . . .
16. Enter global configuration mode:
switch# configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
switch(config)#
17. Re-enable access to the switch HTTP pages:
switch(config)# IP http server
18. Exit global configuration mode:
switch(config)# end switch#
19. Reload the new image:
switch# reload
System configuration has been modified. Save? [yes/no]:y
Proceed with reload? [confirm]
20. Press Return to confirm the reload.
Your Telnet session ends when the switch resets.
The Cisco IOS Desktop Switching Software Configuration Guide contains procedures for recovering from corrupted software and forgotten passwords. For your convenience, the upgrade CD contains a copy of this guide in PDF format. You can also access this guide online as described in the "Cisco Connection Online" section.
Each image directory on the upgrade CD (such as /c2900XL_Standard_Command) contains a /Recovery directory. The /Recovery directory contains the new image in .bin format. If necessary, you can download the .bin file to replace a corrupted image. For recovery instructions, see the Cisco IOS Desktop Switching Software Configuration Guide.
Cisco Connection Online (CCO) is Cisco Systems' primary, real-time support channel. Maintenance customers and partners can self-register on CCO to obtain additional information and services.
Available 24 hours a day, 7 days a week, CCO provides a wealth of standard and value-added services to Cisco's customers and business partners. CCO services include product information, product documentation, software updates, release notes, technical tips, the Bug Navigator, configuration notes, brochures, descriptions of service offerings, and download access to public and authorized files.
CCO serves a wide variety of users through two interfaces that are updated and enhanced simultaneously: a character-based version and a multimedia version that resides on the World Wide Web (WWW). The character-based CCO supports Zmodem, Kermit, Xmodem, FTP, and Internet e-mail, and it is excellent for quick access to information over lower bandwidths. The WWW version of CCO provides richly formatted documents with photographs, figures, graphics, and video, as well as hyperlinks to related information.
You can access CCO in the following ways:
For a copy of CCO's Frequently Asked Questions (FAQ), contact cco-help@cisco.com. For additional information, contact cco-team@cisco.com.
If you are a network administrator and need personal technical assistance with a Cisco product that is under warranty or covered by a maintenance contract, contact Cisco's Technical Assistance Center (TAC) at 800 553-2447, 408 526-7209, or tac@cisco.com. To obtain general information about Cisco Systems, Cisco products, or upgrades, contact 800 553-6387, 408 526-7208, or cs-rep@cisco.com.
Cisco documentation and additional literature are available in a CD-ROM package, which ships with your product. The Documentation CD-ROM, a member of the Cisco Connection Family, is updated monthly. Therefore, it might be more up to date than printed documentation. To order additional copies of the Documentation CD-ROM, contact your local sales representative or call customer service. The CD-ROM package is available as a single package or as an annual subscription. You can also access Cisco documentation on the World Wide Web at http://www.cisco.com, http://www-china.cisco.com, or http://www-europe.cisco.com.
If you are reading Cisco product documentation on the World Wide Web, you can submit comments electronically. Click Feedback in the toolbar, and select Documentation. After you complete the form, click Submit to send it to Cisco. We appreciate your comments.
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Thu Apr 6 19:18:13 PDT 2000
Copyright 1989 - 2000©Cisco Systems Inc.