Table A-1, Table A-2, and Table A-3 list the technical specifications for the Catalyst
2900 series XL switches. For WS-C2912MF-XL, WS-C2924M-XL-A, and WS-C2924M-XL-EN switches, refer to the Catalyst 2900 Series XL Modules Installation Guide and the Catalyst 2900 Series XL ATM Modules Installation Guide for additional specifications.
Table A-4 lists the agency approvals for EMI and safety.
| Catalyst 2912 XL | Catalyst 2912MF XL | |
Environmental Ranges | |||
| Operating temperature | 32 to 113°F (0 to 45°C) | 32 to 113°F (0 to 45°C) |
| Storage temperature | -4 to 149°F (-10 to 65°C) | -4 to 149°F (-10 to 65°C) |
| Operating humidity | 10 to 85% (noncondensing) | 10 to 85% (noncondensing) |
| Operating altitude | Up to 10000 ft (3000 m) | Up to 10000 ft (3000 m) |
| Storage altitude | Up to 15000 ft (4570m) | Up to 15000 ft (4570 m) |
Power Requirements |
|
| |
| 100 to 127/200 to 240 VAC | 100 to 127/200 to 240 VAC (autoranging) 50 to 60 Hz | |
| DC input voltages | +5V | +5V +5V |
| Power consumption | 70W (maximum) 239 Btus per hour | 90W (maximum) 170W (with two modules installed) |
Physical Dimensions |
|
| |
| Weight | 7 lb (3.2 kg) | 14 lb (6.3 kg) 15.5 lb (7.1 kg with two modules installed) |
| Dimensions (H x W x D) | 1.73 x 17.5 x 9.79 in. | 3.46 x 17.5 x 12 in. |
| Catalyst 2924 XL | Catalyst 2924C XL | |
Environmental Operating Ranges | |||
| Operating temperature | 32 to 113°F (0 to 45°C) | 32 to 113°F (0 to 45°C) |
| Storage temperature | -4 to 149°F (-10 to 65°C) | -4 to 149°F (-10 to 65°C) |
| Operating humidity | 10 to 85% (noncondensing) | 10 to 85% (noncondensing) |
| Operating altitude | Up to 10000 ft (3000 m) | Up to 10000 ft (3000 m) |
| Storage altitude | Up to 15000 ft (4570 m) | Up to 15000 ft (4570 m) |
Power Requirements |
|
| |
| 100 to 127/200 to 240 VAC | 100 to 127/200 to 240 VAC | |
| DC input voltages | +5V | +5V |
| Power consumption | 70W (maximum) 239 Btus per hour | 70W (maximum) 239 Btus per hour |
Physical Dimensions |
|
| |
| Weight | 7 lb (3.2 kg) | 7 lb (3.2 kg) |
| Dimensions (H x W x D) | 1.73 x 17.5 x 9.79 in. | 1.73 x 17.5 x 9.79 in. |
Fiber-Port Power Levels |
|
| |
| Optical transmitter wavelength | --- | 1300 nm1 |
| Optical sensibility of the receiver | --- | -14 dBm2 |
| Optical power transmitter | --- | -19 dBm to -14 dBm |
| Transmit | --- | -19 dBm to -14 dBm |
| 1nm = nanometers 2dBm = decibel milliwatt |
| Catalyst 2924M XL | |
Environmental Operating Ranges | ||
| Operating temperature | 32 to 113°F (0 to 45°C) |
| Storage temperature | -4 to 149°F (-10 to 65°C) |
| Operating humidity | 10 to 85% (noncondensing) |
| Operating altitude | Up to 10000 ft (3000 m) |
| Storage altitude | Up to 15000 ft (4570 m) |
Power Requirements |
| |
| 100 to 127/200 to 240 VAC | |
| DC input voltages | +5V +5V |
| Power consumption | 90W (maximum) 170W (with two modules installed) |
Physical Dimensions |
| |
| Weight | 13.5 lb (6.12 kg) 15 lb (6.8 kg with two modules installed) |
| Dimensions (H x W x D) | 3.46 x 17.5 x 12 in. |
| Safety | EMI |
UL 1950/CSA 22.2 No. 950 | FCC Part 15 Class A |
IEC 950/EN 60950 | EN 55022 Class A (CISPR 22 Class A) |
AS/NZS 3260, TS001 | VCCI Class A |
CE | AS/NZS 3548 Class A |
| BCIQ |
| CE |
![]()
![]()
![]()
![]()
![]()
![]()
![]()