These release notes provide information on the Catalyst 2820 series standard edition Ethernet switches (hereafter referred to as the Catalyst 2820 switches) using firmware version 8.01.
Note This document describes the problems resolved in the 8.01.00 firmware version.
The tracking numbers for some items in this document are added for your convenience.
Notes, cautions, and warnings in this document use the following conventions and symbols:
Note Means reader take note. Notes contain helpful suggestions or references to materials not contained in this document.
 | Caution
This caution symbol means reader be careful. In this situation, you might do something that could result in equipment damage or loss of data. |
 | Warning
This warning symbol means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents. (To see translations of the warnings that appear in this publication, refer to the Catalyst 2820 Series Installation and Configuration Guide.) |
The Catalyst 2820 switches are now shipped with firmware version 8.01.00. Depending on the hardware board revision of your switch, the minimum firmware releases listed in Table 1 are required.
The "System Revision" field on the System Configuration menu displays the board revision of your switch.
The Firmware Configuration Menu and the Console and Upgrade Configuration page display the firmware version in use.
The following information is for FCC compliance of Class A devices: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio-frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case users will be required to correct the interference at their own expense.

The following sections describe the problems resolved in the 8.01.00 firmware version:
- The following FDDI port options now work properly on the web console [CSCdk04976 and CSCdk05207]:
- Novell SNAP Translation and Unmatched SNAP Translation options on the Module Management page.
- Novell SNAP frame translation and Unmatched SNAP frame destination options on the Port Configuration Page (for FDDI ports).
- The web console password caching on the switch has been removed. The web console prompts for a password each time you access the web console for the first time from a particular web browser. [CSCdk23516]
- The switch no longer requests a new IP address via DHCP after one has been assigned either manually or via DHCP. [CSCdk36548]
- The switch now uses the same MAC address in all Address Resolution Protocol (ARP) and IP packets. [CSCdj30656]
- When the switch gathers information through Cisco Discovery Protocol (CDP), the switch no longer adds a null character at the end of the port ID of the neighboring device. [CSCdk43290]
- Remote Monitoring (RMON) can now occur on all ports concurrently. Previously, you could monitor a maximum of ten ports simultaneously.
- The switch automatically creates an entry per port in the RMON etherStatsTable. [CSCdk14345]
- To clear all cached domain name system addresses from the switch, use the Clear cached DNS entries option on the IP Configuration menu. [CSCdk02971]
- After removing or inserting a module, click Reload to display a fresh copy of the switch image on the Basic System Configuration page.
- When using Netscape Communicator 4.xx on Sun workstations, minimized and maximized pages of the web console might not refresh properly. Click Reload to refresh the page.
- In addition, when using Netscape Communicator 4.xx on PCs and Sun workstations, resized pages of the web console might not refresh properly. Click Reload to refresh the page. [CSCdj85607]
- Click Reload from any web console page to display a fresh copy of the Basic System Configuration page, not the currently displayed page.
- When using Netscape Communicator 4.xx on Windows 95, clicking Apply after making changes to the Port Security Table page sometimes displays a blank page. Click Stop to redisplay the Port Security Table page with your changes saved. [CSCdj95153]
- The web console does not check parameter values that are outside the value range. If you enter an invalid parameter value, the web console redisplays the console page with the original value. Parameter value ranges are shown in the menu console and in the Catalyst 2820 Series Installation and Configuration Guide.
- Do not use the following settings for the console port when upgrading the switch through the XMODEM protocol: 9600 baud, 7 data bits, 2 stop bits, and Even parity. Use other settings or the console port default settings (9600 baud, 8 data bits, 1 stop bit, and no parity). [CSCdj87375]
- If you use bridge groups and Spanning-Tree Protocol (STP) is disabled on a bridge group, the switch does not forward the bridge protocol data units (BPDUs) received on any ports in the bridge group to other members of the bridge group. If you are running STP on the rest of your network, this might result in network loops if the switch connects to other switches. [CSCdk01665]
- If the problem occurs and you want to use bridge groups with STP disabled, you must disable STP on all bridge groups so that the switch forwards received BPDUs. Assign at least one port to all bridge groups, and then disable STP for each bridge group, using the Bridge Group Spanning Tree Configuration menu (or SNMP). You can then reassign the ports to whichever group you wish.
- RMON statistics gathering has the following maximum limits:
- 27 rows in these tables: etherStatsTable, historyControlTable, alarmTable, and eventTable.
- 20 history buckets per historyControlTable entry.
- If you are logging events, you can have 10 entries per event and the list is circular.
- The Catalyst 2820 switches now ship only with the RJ-45-to-DB-9 female DTE
(labeled PC) and RJ-45-to-DB-25 male DCE (labeled Modem) adapters. Disregard text in the Catalyst 2820 Series Installation and Configuration Guide that refer to the supplied RJ-45-to-DB-25 female DTE adapter. You can order this adapter from Cisco (order number CAB-500DTF).
- The RPS LED description in the Catalyst 2820 Series Installation and Configuration Guide should state that the RPS LED blinks green, not amber, when both the redundant power system (RPS) and the internal power supply are powered up.
- If you try to upgrade the module firmware from the web console and the Module (Slot A or B) TFTP Upgrade button is not on the Console and Upgrade Configuration page, the module firmware is corrupted. Do not continue the upgrade attempt from the web console. Use the menu console to upgrade the module firmware. [CSCdj92758]
- If your attempt to upgrade the ATM module firmware fails while the module is operating normally, the expansion slot LED on the switch turns amber. The module continues operation, but the module image in Flash memory is corrupted. When you reset the ATM module, it will not find a valid Cisco IOS image, and the ATM module will not pass the power-on self-test (POST). To correct this problem, repeat the firmware upgrade procedure to download a new firmware image on the ATM module.
- If you connect an autonegotiating 100BaseTX switch module port of a Catalyst 2820 switch to a device that does not autonegotiate, there could be problems establishing a link. To work around this problem, configure the switch 100BaseTX module port for either half or full duplex to match the configuration of the other device.
- After you select Auto-negotiate as the 100BaseTX switch module port duplex mode on the web console Module Management page and click Apply, "Auto-negotiate" displays in the Actual field while the switch and the other device negotiate the duplex mode. Click the Module option on the web console action bar to display the final duplex state of the port. [CSCdk03911]
- Be sure that JavaScript is enabled. From Netscape Communicator 4.xx, select Edit > Preferences > Advanced > Enable JavaScript. JavaScript is enabled by default on Microsoft Internet Explorer.
- Be sure the web console page is updated whenever you visit the page. Set the caching of pages to Every time on Netscape Communicator or Once per session on Microsoft Internet Explorer.
- You can bookmark the switch IP address to easily retrieve the web console for later use.
- If you are using Netscape Communicator, choose the Communicator menu option, and select Bookmarks > Add Bookmark.
- If you are using Microsoft Internet Explorer, choose the Favorites menu option, and select Add to Favorites.
- Do not use the right mouse-button to bookmark the switch IP address; doing so only saves the specific frame (image) of the web console page.
- If the switch is directly connected to a terminal or terminal emulator rather than to a modem connection, you must configure the switch to the same baud rate and character format as the terminal or emulator.
- If the switch is dialing out, the configured baud rate of the switch does not change. The Match Remote Baud rate option (auto baud) applies only when the switch is answering an incoming call and matches a rate less than or equal to the configured rate. When the call is over, the switch reverts to the last configured baud rate.
- Be sure that the port monitoring feature (used for diagnostics) is disabled during normal operation. Enabling the port monitoring feature can degrade the performance of the switch.
- Bridge group configuration is supported on the menu console, but not the web console.
- When you have bridge groups enabled, the web console displays information for bridge group 1 only.
- Do not connect a port that belongs to more than one bridge group to another port in any of those bridge groups; this will cause a network loop.
- When the switch initializes after a reset, the port experiences the complete Spanning-Tree Protocol (STP) transition, as specified by IEEE 802.1D, even if Port Fast mode is enabled. Once the transition is complete, the Port Fast mode setting is enforced. This process ensures that no temporary loop is formed after a reset and allows STP to safely discover the topology of the network.
- Switch configuration changes take effect immediately. However, the switch requires 30 seconds to write changed parameters to permanent storage. If you turn off the switch too soon, the change does not take effect the next time the system is restarted.
- While performing a firmware upgrade, the switch might not respond to commands for as long as 1 minute. This is normal and correct. If you interrupt the transfer by turning the switch off and on, the firmware could be corrupted. If this happens, follow the procedure described in "Using the Diagnostic Console" in the "Troubleshooting" chapter of the Catalyst 2820 Series Installation and Configuration Guide.
Use the Catalyst 2820 Series Installation and Configuration Guide with this document.
Cisco Connection Online (CCO) is Cisco Systems' primary, real-time support channel. Maintenance customers and partners can self-register on CCO to obtain additional information and services.
Available 24 hours a day, 7 days a week, CCO provides a wealth of standard and value-added services to Cisco's customers and business partners. CCO services include product information, product documentation, software updates, release notes, technical tips, the Bug Navigator, configuration notes, brochures, descriptions of service offerings, and download access to public and authorized files.
CCO serves a wide variety of users through two interfaces that are updated and enhanced simultaneously: a character-based version and a multimedia version that resides on the World Wide Web (WWW). The character-based CCO supports Zmodem, Kermit, Xmodem, FTP, and Internet e-mail, and it is excellent for quick access to information over lower bandwidths. The WWW version of CCO provides richly formatted documents with photographs, figures, graphics, and video, as well as hyperlinks to related information.
You can access CCO in the following ways:
- WWW: http://www.cisco.com
- Telnet: cco.cisco.com
- Modem: From North America, 408 526-8070; from Europe, 33 1 64 46 40 82. Use the following terminal settings: VT100 emulation; databits: 8; parity: none; stop bits: 1; and connection rates up to 28.8 kbps.
For a copy of CCO's Frequently Asked Questions (FAQ), contact cco-help@cisco.com. For additional information, contact cco-team@cisco.com.
Note If you are a network administrator and need personal technical assistance with a Cisco product that is under warranty or covered by a maintenance contract, contact Cisco's Technical Assistance Center (TAC) at 800 553-2447, 408 526-7209, or tac@cisco.com. To obtain general information about Cisco Systems, Cisco products, or upgrades, contact 800 553-6387, 408 526-7208, or cs-rep@cisco.com.
Cisco documentation and additional literature are available in a CD-ROM package, which ships with your product. The Documentation CD-ROM, a member of the Cisco Connection Family, is updated monthly. Therefore, it might be more up to date than printed documentation. To order additional copies of the Documentation CD-ROM, contact your local sales representative or call customer service. The CD-ROM package is orderable as a single package or as an annual subscription on the World Wide Web at http://www.cisco.com/subscription. You can also access Cisco documentation on the World Wide Web at http://www.cisco.com, http://www-china.cisco.com, or http://www-europe.cisco.com.
If you are reading Cisco product documentation on the World Wide Web, you can submit comments electronically. Click Feedback in the toolbar and select Documentation. After you complete the form, click Submit to send it to Cisco. We appreciate your comments.
Copyright 1989-1998
©
Cisco Systems Inc.