To update the firmware configuration of the Catalyst 1900 and Catalyst 2820 switches, use the Firmware Configuration Menu. The Firmware Configuration Menu (see Figure B-1) is displayed when you select the [F] option from the Management Console Main Menu. Use this menu to display the firmware version used by the switch and to perform firmware upgrades. The size of the Flash memory is displayed in the System Information area in the menu. The Upgrade status field in the System Information area shows if a firmware upgrade is in progress.
Catalyst 2820 - Firmware Configuration -----------------System Information------------ FLASH: 1024K bytes V8.00.00 Standard Edition Upgrade status: No upgrade currently in progress. --------------------Settings------------------ [S] TFTP Server name or IP address [F] Filename for firmware upgrades [A] Accept upgrade transfer from other hosts Enabled --------------------Actions------------------- [U] System XMODEM upgrade [D] Download test subsystem (XMODEM) [T] System TFTP upgrade [X] Exit to Main Menu Enter Selection:
![]() | Caution During the download of the upgrade file, the switch might not respond to commands for as long as 1 minute. This is normal and correct. If you interrupt the download by turning the switch off and on, the firmware could be corrupted. If this happens, restart the firmware following the procedure described in the "Using the Diagnostic Console" section in the "Troubleshooting" chapter of the Catalyst 1900 or Catalyst 2820 installation documents. |
How you upgrade the firmware depends on your installation:
[A] Accept upgrade transfer from other hosts---Enable [E] or disable [D] the switch from accepting an upgrade from another host on the network. To prevent unauthorized upgrades, use the Disabled setting. The default setting is Enabled.
[D] Download test subsystem (XMODEM)---For Cisco personnel only.
[X] Exit to Main Menu---Display the Management Console Main Menu.
The following sections provide information on the [S], [F], [U], and [T] options on the Firmware Configuration Menu.
To download the switch firmware from a TFTP server, follow these steps:
Step 1 From the Firmware Configuration Menu, select the [S] option, and enter the IP address or name of the TFTP server where the upgrade file is located.
Step 2 Select the [F] option from the menu, and enter the name of the upgrade file.
Step 3 Select the [T] option from the menu to initiate the TFTP download.
The switch contacts the server to download the upgrade file to the switch.
Step 4 Verify the upgrade is in progress by checking the Upgrade status field in the System Information area on the menu.
If the upgrade is in progress, the field reads in-progress.
After the download, the switch does not respond to commands for approximately 1 minute. When the download is complete, the switch resets and begins using the new firmware.
To download the switch firmware from a TFTP client, follow these steps:
Step 1 From the TFTP client workstation, establish a TFTP session with the IP address assigned to the switch.
Step 2 Ensure that the TFTP client is in binary transfer mode.
Step 3 Use the appropriate command (such as, put upgrade_filename) to download the upgrade file from the client workstation to the switch.
Step 4 Verify the upgrade is in progress by checking the System Information section of the Firmware Configuration Menu.
If the upgrade is in progress, the field reads in-progress.
After the download, the switch does not respond to commands for approximately 1 minute. When the download is complete, the switch resets and begins using the new firmware.
To download the switch firmware via XMODEM, follow these steps:
Step 1 Enter the baud rate (2400, 9600, 19200, 38400, or 57600) of the console port on the switch and the management station. You can set the baud rate for the console port from the RS-232 Port Configuration Menu.
Step 2 From the Firmware Configuration Menu, select the [U] option to use the XMODEM protocol to download the upgrade file.
Step 3 At the prompt, select Y to start the download.
After the download, the switch does not respond to commands for approximately 1 minute. When the download is complete, the switch resets and begins using the new firmware.
This procedure is for upgrading the FDDI and ATM module firmware, not the switch firmware. The options you use in this procedure depend on the expansion slot containing the FDDI or ATM module.
To download the module firmware from a TFTP server, follow these steps:
Step 1 From the Firmware Configuration Menu, select the [S] option, and enter the
IP address or name of the TFTP server where the FDDI or ATM upgrade file is located.
Step 2 Select the [F] option from the menu, and enter the name of the upgrade file.
Step 3 Select the [3] option (for slot A) or the [4] option (for slot B) to initiate the TFTP download.
The switch contacts the server to download the upgrade file to the switch.
Step 4 Verify the upgrade is in progress by checking the System Information section of the Firmware Upgrade Menu.
If the upgrade is in progress, the field reads in-progress.
When the download is complete, the FDDI or ATM module resets and begins using the new firmware.
This procedure is for upgrading the FDDI and ATM module firmware, not the switch firmware. The options you use in this procedure depend on the expansion slot containing the FDDI or ATM module.
To download the module firmware from a TFTP server, follow these steps:
Step 2 Ensure that the TFTP client is in binary transfer mode.
Step 3 Use the appropriate command (such as, put upgrade_filename) to download the upgrade file from the client workstation to the switch.
If there are two FDDI or two ATM modules installed, the following rules apply:
Step 4 Verify the upgrade is in progress by checking the System Information section of the Firmware Upgrade Menu.
If the upgrade is in progress, the field reads in-progress.When the download is complete, the FDDI or ATM module resets and begins using the new firmware.
This procedure is largely dependent on the modem software you are using. ProComm and HyperTerminal are examples of applications that use the XMODEM protocol.
To download the switch firmware via XMODEM, follow these steps:
Step 1 Enter the baud rate (2400, 9600, 19200, 38400, or 57600) of the console port on the switch and the management station. You can set the baud rate for the console port from the RS-232 Port Configuration Menu.
Step 2 From the Firmware Configuration Menu, select the [U] option to use the XMODEM protocol to download the upgrade file.
Step 3 Select the [1] option (for slot A) or the [2] option (for slot B).
Step 4 At the prompt, select Y to start the download.
Step 5 Verify the upgrade is in progress by checking the System Information section of the Firmware Upgrade Menu.
If the upgrade is in progress, the field reads in-progress.
When the download is complete, the FDDI or ATM module resets and begins using the new firmware.
[S] Server: IP address of TFTP server---Enter the IP address of the TFTP server where the upgrade file is located.
[F] Filename for firmware upgrades---Enter the name of the firmware upgrade file to be downloaded, and press Return.
[A] Accept upgrade transfer from other hosts---You have the option of accepting upgrades from TFTP clients on the network. Use this option to enable or disable this function, and press Return.
[1] FDDI or ATM (A) XMODEM upgrade---Start an XMODEM upgrade of the FDDI or ATM firmware in expansion slot A.
[2] FDDI or ATM (B) XMODEM upgrade---Start an XMODEM upgrade of the FDDI firmware in expansion slot B.
[3] FDDI or ATM (A) TFTP upgrade---Initiate a TFTP download of FDDI firmware to slot A. The complete procedure is described in the "Downloading the Module Firmware from a TFTP Server" section earlier in this chapter.
[4] FDDI or ATM (B) TFTP upgrade---Initiate a TFTP download of FDDI firmware to slot B. The complete procedure is described in the "Downloading the Module Firmware from a TFTP Server" section earlier in this chapter.
[U] System XMODEM upgrade---Select this option to upgrade the firmware using a modem. Enter N to return to the Firmware Upgrade Menu or Y to begin the download. The following prompt appears:
Please initiate XMODEM transfer. Awaiting transfer . . . C
C is the first XMODEM/CR protocol request. Use the appropriate application-specific command to start the download. When the download is complete, the switch resets, and the newly downloaded firmware begins to execute. The Logon Security Menu is displayed.
[T] System TFTP upgrade---Upgrade the firmware from a TFTP server. The address of the server and the name of the file must already be set.
[D] Download test subsystem (XMODEM)---This option is reserved for use by the customer support group and is used to download diagnostic software.
|
|