This appendix provides the technical specifications and regulatory agency approvals
(see Table A-1) for the switch. For information about the Catalyst 2820 modules, refer to the Catalyst 2820 Modules User Guide and the Catalyst 2820 ATM Modules Installation and Configuration Guide.
| Environmental Operating Ranges |
| |
| Operating temperature | 23 to 113ºF (-5 to 45ºC) |
| Storage temperature | -13 to 158ºF (-25 to 70ºC) |
| Operating humidity | 10 to 85% (noncondensing) |
| Operating altitude | Up to 9842 ft (3000 m) |
| Power Requirements |
| |
| AC input voltage | 100 to 127/200 to 240 VAC (autoranging) 50 to 60 Hz |
| DC input voltage | +5V |
| Power consumption | 100W |
| Physical Dimensions |
| |
| 13 lb (5.9 kg) | |
| 3.5 x 17.5 x 12 in. (8.9 x 44.5 x 30.5 cm) | |
| Agency Approvals |
| |
| Safety | EMI |
| AS/NZS 3260, TS001 | FCC Part 15 Class A |
| UL 1950/CSA 22.2 No. 950 | EN 55022A Class A (CISPR 22 Class A) |
| IEC 950/EN 60950 | VCCI Class A |
| NOM 019 | AS/NRZ 3548 Class A |
|
|