This appendix provides the technical specifications and regulatory agency approvals
(see Table A-1) for the switch.
| Environmental Operating Ranges | ||
| Operating temperature | 23 to 113×F (-5 to 45×C) | |
| Storage temperature | -13 to 158×F (-25 to 70×C) | |
| Operating humidity | 10 to 85% (noncondensing) | |
| Operating altitude | Up to 9842 ft (3000 m) | |
| Power Requirements | ||
| AC input voltage | 90 to 127/200 to 250 VAC (autoranging) 50 to 60 Hz | |
| DC input voltage | +5V@6A, +12V@1A | |
| Power consumption | 50W | |
| Physical Dimensions | ||
| Weight | 7 lb (3.2 kg) | |
| Dimensions (H x W x D) | 1.73 x 17.5 x 8.25 in. (4.4 x 44.5 x 21 cm) | |
| Safety | EMI | |
| AS/NZS 3260, TS001 | FCC Part 15 Class B | |
| UL 1950/CSA 22.2 No. 950 | EN 55022B Class B (CISPR 22 Class B) | |
| IEC 950/EN 60950 | VCCI Class II | |
| NOM 019 | AS/NRZ 3548 Class B | |
|
|