Table A-1 describes the route processor and interface module specifications.
For the 13-slot chassis and common equipment specifications, refer to the Catalyst 8540 Chassis Installation Guide.
| Description | Specifications |
|---|---|
Route processor capacity | 40-Gbps shared memory, nonblocking switch fabric |
Dimensions (H x W x D) | 1.2 x 14.4 x 16 in. (3.0 x 36.6 x 40.6 cm) |
Weight | Processor: 6.85 lb (3.09 kg) |
DC voltages supplied and steady-state maximum current ratings | |
Operating temperature | 32 to 104ºF (0 to 40ºC) |
Nonoperating temperature | -40 to 167ºF (-40 to 75ºC) |
Humidity | 10 to 90%, noncondensing |
Altitude | -500 to 10,000 ft (-52 to 3048 m) |
Microprocessor | 100-MHz MIP3 R4700 |
Memory | 8-MB Flash memory SIMM4 (upgradable to 16 MB) |
Management access | Standard Ethernet and EIA/TIA-2328 serial port on the route processor |
Interface ports | RJ-45 IEEE9 802.3 Ethernet 10BaseT port |
Interface Modules | 16 10/100BaseT Ethernet ports (RJ-45), 16 KB or 64 KB of RAM |
Network management | Port TX10, RX11, and link LEDs12 |
Management Information Bases (MIBs) | SNMP16 MIB II (RFC 1213) |
Maximum | UTP cable17: 328 ft (100 m) with four or fewer separate cable segments on the path; 50/125-micron and 62.5/125-micron multimode fiber: 1640 ft (500 m) |
Fiber-Optic Power Levels: | 1261 to 1360 nm18 |
Compliance: | CE Marking (European Union) |
| UL 195020, CSA-C22.2 No. 95021, EN 6095022, IEC 6095023, TS 00124, AS/NZS 326025 |
| FCC27 Part 15 Class A (CFR 47 , Part 15), CISPR 22 Class A, EN 55022 Class A, VCCI28 Class A, and AS/NZS 3548 Class A with UTP cables, EN 55022 Class B, CISPR 22 Class B, VCCI Class B, and AS/NZS 3548, Class B with FTP cables29 |
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Posted: Wed Aug 2 15:08:44 PDT 2000