cc/td/doc/product/l3sw/8540/rel_12_0
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

Quick Reference
Catalyst 8540 CSR and MSR
Hardware Information

Quick Reference
Catalyst 8540 CSR and MSR
Hardware Information

Chassis Installation

Replacing Components

Ports and Cabling

LEDs and Troubleshooting

Distance and Pinout Information

Maximum Transmission Distances

Transceiver Speed Cable Type Max. Distance Between Stations

10/100-Mbps Ethernet

Category 5 UTP

328 feet (100 m)

100-Mbps Ethernet

Multimode fiber

1640 feet (500 m)

1000-Mbps Ethernet

Multimode fiber

1640 feet (500 m)

1000-Mbps Ethernet

Single-mode fiber

16404 feet (5 km)

OC-3c, 155-Mbps ATM

Single-mode fiber

9 miles (15 km)

OC-3c, 155-Mbps ATM

Single-mode fiber, long reach

18 miles (30 km)

OC-3c, 155-Mbps ATM

Multimode fiber

1.2 miles (2 km)

OC-12c, 622-Mbps

Single-mode fiber, intermediate reach

9 miles (15 km)

OC-12c, 622-Mbps

Single-mode fiber, long reach

25 miles (40 km)1

OC-12c, 622-Mbps

Multimode fiber

1640 feet (500 m)

OC-48c, 2488-Mbps

Single-mode fiber, intermediate reach

9 miles (15 km)

OC-48c, 2488-Mbps

Single-mode fiber, long reach

50 miles (80 km)

T1, 1.544-Mbps ATM

Category 5 twisted-pair

650 feet (198 m)

E1, 2.048-Mbps ATM

Category 5 twisted-pair and FTP (120 ohm)

650 feet (198 m)

E1, 2.048-Mbps ATM

Coaxial cable (75 ohm)

650 feet (198 m)

CE1, 2.048-Mbps ATM

Category 5 twisted-pair

650 feet (198 m)

CES T1

Category 5 twisted-pair and FTP

650 feet (198 m)

CES E1

Category 5 twisted-pair and FTP (120 ohm)

820 feet (248.5 m)

CES E1

Coaxial cable (75 ohm)

650 feet (198 m)

DS3, 45-Mbps

Coaxial cable

450 feet (137 m)

E3, 34-Mbps

Coaxial cable

1299 feet (296 m)

CDS3, 45-Mbps

Coaxial cable

450 feet (137 m)

1If you are attaching a short cable to the 622-Mbps long-reach port adapter, you must add 10 dB of attenuation to the cable or the transmitter might overdrive the receiver and introduce data errors.

Pinouts to RJ-45 Connectors

The 10/100 Mbps Ethernet interface module with unshielded twisted-pair (UTP) ports supports RJ-45 connectors. The following table lists the signals for RJ-45 cable connectors.
Pin Signal Description

1

RxD+

Receive data +

2

RxD-

Receive data -

3

NC

No connection

4

NC

No connection

5

NC

No connection

6

NC

No connection

7

TxD+

Transmit data +

8

TxD-

Transmit data -

Pinouts to RJ-48c Connectors

The T1, E1, T1 CES and E1 port adapters support RJ-48c connectors. The following table lists the signals for RJ-48c connectors.
Pin Description

1

Receive ring

2

Receive tip

3

No connection

4

Transmit ring

5

Transmit tip

6

No connection

7

No connection

8

No connection

Regulatory and Compliance Information

Specifications

The following table lists the specifications for the Catalyst 8540.
Description

Specifications

Dimensions (H x W x D)

1.2 x 14.4 x 16 in. (3.0 x 36.6 x 40.6 cm)
Port adapter: 1.2 x 6.5 x 10 in. (3.0 x 16.5 x 25.4 cm)
Interface Module: 1.2 x 14.4 x 16 in. (3.0 x 36.6 x 40.6 cm)
Interface Module (OC-48c): 2.37 x 14.4 x 16.26 in.
(3.0 x 36.6 x 40.6 cm)

Weight

Processor: 6.85 lb (3.09 kg)
Interface modules: 3.55 lb (1.60 kg)
Port adapter (approximately): 1.10 lb (0.50 kg)
Chassis only: 70 lb (31.7 kg)
Chassis fully configured with 2 route processors, 8 line modules, 3 switch modules,
and 2 power supplies:160 lb (72.5 kg)

DC voltages supplied and steady-state maximum current ratings

+3V3 @ 15.0A
+5V @ 5.0A
+12V @ 6.0A
+42V @ 28.84A

AC voltages supplied and steady-state maximum current ratings

+3V3 @ 15.0A
+5V @ 5.0A
+12V @ 6.0A
+42V @ 27.46A

Operating temperature

32 to 104ºF (0 to 40ºC)

Nonoperating temperature

-40 to 167ºF (-40 to 75ºC)

Humidity

10 to 90% noncondensing

Altitude

-500 to 10,000 ft (-52 to 3048 m)

.
Description

Specifications

Regulatory Compliance

UL 1950 (U.S.)
CSA 950 (Canada)
EN60950 (European Union)
IEC 950 (International)
AS/NZS 3260 (Australia/New Zealand)
TS001: 1997 (Australia)
21CFR1040 (Laser - U.S.A)
EN60825 (Laser - European Union)
IEC60825 (Laser - International)
CE Marking (European Union)
FCC Part 15 (CFR 47) Class A (U.S.)
VCCI Class A with UTP and Class B with FTP cables (International)
EN55022 Class A with UTP and Class B with FTP cables (European Union)
CISPR 22 Class A with UTP and Class B with FTP cables (International)
AS/NZS 3548 Class A with UTP and Class B with FTP cables (Australia/New Zealand)


hometocprevnextglossaryfeedbacksearchhelp
Posted: Tue Sep 12 10:58:52 PDT 2000
Copyright 1989-2000©Cisco Systems Inc.